31C-027 N V7A 25. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5' from the duct outlet for all fireplaces 26. Fire and draft stopping shall be completed before rough inspection. 780 CMR R302. 27. Ignition barriers in place before final. 780 CMR R316. 28. Dwelling /Garage fire separation. An attached garage (within 3' of main structure) is required to have %2 drywall on the garage side of the separation wall and if there is a finished space above the garage all walls must have %2" drywall and the ceiling 5/8" drywall. 780 CMR R302.6 29. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. A signed copy of the Thermal Bypass Checklist. d. Energy information including mechanical equipment posted on the electric panel. e. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Windows and the Thermal Bypass Checklist. Duct blast testing when practicable. 30. Vapor retarders. Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer (diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99% of the moisture in a structure. This is evident every time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 31. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 32. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note: ThruLoks are engineered for post attachment supporting a railing. 33. Smoke and CO detectors as required. 780 CMR R314 and R315. 34. Closets beneath stair which have doors must be drywalled with %z ". 780 CMR R302.7 35. If there is mechanical equipment or a combustible roof, 30 sqft of space, and 30" measured from top of ceiling joist to bottom of rafters an attic access of minimum RO of 22" x 30" is required to be located in an accessible place. It must be insulated, gasketed, and secured in place. 780 CMR R807 Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. My email address is: cmiller Thank you for your cooperation on these matters. Chuck Miller City of Northampton Assistant Commissioner and Zoning Enforcement 10. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1 / 3rd 780 CMR R802.3.1 11. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 12. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and number of jack studs required. 13. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss 14. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 15. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basements, 6'4" at beams /ducts. 780 CMR R305.1. MA amended 16. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4 17. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. Order restrictors. 780 CMR R612.2 18. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape. 780 CMR R310 b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft at 1 floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 3/4" from the top of the threshold and only in- swinging doors. 780 CMR R311.3 19. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ", maximum riser 83/4", maximum overall variance for the run is 3/8 ", 4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception, 4 3/8" on balustrade, 6" in the triangle. Graspable rail 13/4" minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 20. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36 ", 4" sphere rule. 780 CMR R312.1. 21. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In interior non - bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1 16ga. strap must extend a minimum of 6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom. Notches are different. 22. Dryer duct transition is limited to 8' of aluminum flex and must be exposed. 780 CMR M1502.4.3 23. Dryer duct maximum equivalent length is 25' or per manufacturer's specs. 780 CMR M1502.4.4.1, no screwed connections. 24. Markup air is required for any exhaust hood of 400 CFM or more. 780 CMR M1503.4 City of Northampton Massachusetts * fl DEPARTMENT OF BUILDING INSPECTIONS l „. " 212 Main Street • Municipal Building °t K,"" ° Northampton, MA 01060 s s 1WeA ti INSPECTOR Kent Pecoy & Sons Construction September 6, 2012 215 Baldwin Street West Springfield, MA 01089 Subject Location: 124 Moser Street Lot A20 Map Block: 31C -027 Mr. Pecoy, Your plans last dated 8 -11 -12 have been approved as noted and per memo. Please follow up on the following items: 1. Stamped structural drawings are required for all none code prescriptive framing. 2. Preservative treated separation between the porch slab and framing members. 3. A smoke /CO detector is required at the bottom of every stair leading to a finished floor above. 4. A smoke /CO detector will be required in the open section of the basement. 5. Attic Access is a requirement see item #35. 6. Northampton is a stretch energy code community therefore a HERS rating is required. a. Any air permeable insulation must be in a sealed cavity, accentually air tight from both sides. The exterior portion is required to be accomplished before rough inspection. b. All penetration in the ceiling must be sealed before attic insulation is installed; an air sealing inspection is required. c. Please be aware of requirements the Thermal Bypass Checklist, a signed copy will be required before a CO can be issued. 7. Planning Decision Hearing conditions of approval # 2, 9, 12, and 13. Proof of completion required. 8. Confirmation of Water and Sewer permits. 9. Attic R -60, f & 2 walls R21 + R7, basement R10, assumed. As of August 4 2011 the 8 Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not intended to be comprehensive, nor is it a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8 Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I soils (table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. 5. Through wall form ties must be removed from both faces and patched with hydraulic cement. 780 CMR R406.2 of amendments. 6. Foundation anchor bolts must be %2" and be embedded a minimum of 7" into the concrete. 10" bolts! 780 CMR R403.1.6 7. CMU foundations require 3/8" parging before damp proofing. 780 CMR R406.1 see exceptions. 8. Emergency escape is required out of every basement whether habitable or not. 780 CMR R310.1 9. Ceiling joist are intended to prevent spread, once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8 -16nd common are required at each connection. 780 CMR R802.3.1. When there is neither of these a structural ridge is required with a load path to the foundation. Planning - Decision City of Northampton Hearing No.: PLN- 2012 -0019 Date: March 29, 2012 required in the special permit for the village. 3. The requested use will have no effect on the relationship of structures and open spaces to the natural landscape, existing buildings and other community assets in the area. 4. The requested use will not have an impact on city resources. 5. The requested use meets any special regulations set forth in the Zoning Ordinance in section 350 -11 COULD NOT DEROGATE BECAUSE: FILING DEADLINE MAILING DATE: HEARING CONTINUED DATE: DECISION DRAFT BY APPEAL DATE: 3/1/2012 3/15/2012 4/5/2012 REFERRALS IN DATE: HEARING DEADLINE DATE: HEARING CLOSE DATE: FINAL SIGNING BY APPEAL DEADLINE: 3/8/2012 4/28/2012 3/22/2012 4/5/2012 4/18/2012 FIRST ADVERTISING DATE. HEARING DATE: VOTING DATE: DECISION DATE 3/8/2012 3/22/2012 3/22/2012 3/29/2012 SECOND ADVERTISING DATE: HEARING TIME VOTING DEADLINE: DECISION DEADLINE: 3/15/2012 7:00 PM 6/20/2012 6/20/2012 MEMBERS PRESENT' VOTE Andrew Weir votes to Grant Debin Bruce votes to Grant Marilyn Richards votes to Grant • Katharine G. Baker votes to Grant Stephen Gilson votes to Grant Jennifer Dieringer votes to Vote Against Francis Johnson votes to Grant MOTION MADE BY SECONDED BY VOTE COUNT' DECISION. Debin Bruce Katharine G. Baker 6 -1 Approved with Conditions MINUTES OF MEETING: Available in the Office of Planning & Development. 1, Carolyn Misch, as agent to the Planning Board, certify that this is a true and accurate decision made by the Planning Board and certify that a copy of this and all plans have been filed with the Board and the City Clerk on the date shown above. I certify that a copy of this decision has been mailed to the Owner and Applicant. Notice of Appeal An appeal from the decision of the Planning Board may be made by any person aggrieved pursuant to MGL Chapt. 40A, Section 17 as amended within twenty (20) days after the date of the filing of the notice of the decision with the City Clerk. The date is listed above. Such appeal may be made to the Hampshire Superior Court with a certified copy of the appeal sent to the City Clerk of the City of Northampton. GeoTMS® 2012 Des Lauriers Municipal Solutions, Inc. Planning - Decision City of Northampton Hearing No.: PLN- 2012 -0019 Date: March 29, 2012 11.) All air conditioner condensers shall be screened from street view by buildings or plantings. 12.) Prior to construction onsite inspection of silt fence, tree protection, and catch basin protection shall be done by the city to confirm they have been installed as shown in plans. 13.) All technical standards required by Department of Public Works for development shall be met.(attached herein) Curb Cut •Acceptance of this street will require that the DPW policy regarding a 5 year moratorium on cuts in newly paved roads be adhered to. The DPW policy is that cuts made within this time require milling and overlay for the full width of the road and 20' wide each way from centerline of the two new cut(s) as well as backfill with flowable fill in all trenches. •The proposed common drive at lots A21 and A2 has a throat that is approximately 25 feet wide at the sidewalk with perpendicular, individual drives. •At all proposed new curb cuts the concrete sidewalk shall be rebuilt the nearest panel that is included in the driveway limits and shall meet the DPW standards of: 8 -inch, compacted gravel base, 6 -inch thick, 4,000 psi concrete with 6 "x6 "x 10110 WWF and 3/8" filler w /joint sealant and retainer ring. •A detail for setting granite curb shall be provided for approval by Department of Public Works. Sewer •Existing sewer stubs may fall near or within the limits of proposed new driveway locations. Sewer cleanouts near or within vehicular trafficked areas shall be protected within an access box that is flush with the surrounding grade. •Sewer cleanouts shall be placed as close to the property line as practicable. Drainage: •The Northampton DPW issued a Stormwater Management Permit to TCB Hospital Hill LLC on July 19, 2007, which included potential development consistent with the proposed project. However, the Stormwater Management Permit included conditions which must be met for the proposed project including the following (see Stormwater Management Permit for Village Hill Phase 2 for more information): -This project will be required to submit one or more Notice of Intent (NO I) to the U.S. EPA for coverage under the NPDES Stormwater Construction General Permit. A copy of the final NOI and Stormwater Pollution Prevention Plan (SWPPP) shall be submitted to the Northampton DPW for approval prior to the start of construction and prior to issuance of a building permit. -The plans and specifications approved by this Permit include roadways and conceptual impervious surface areas for site development. During the Site Plan approval, 40R site approval, or any other permitting for each lot, the applicant must submit documentation to the Northampton DPW of the proposed drainage system for the site, the impervious surface footprint of the site, and a revised summary of impervious surface areas built, proposed, and available for future construction for the sub - watershed drainage area where the proposed lot development is taking place. The DPW requests that this information be submitted and approved by the DPW prior to issuance of a building permit. •Sheet CI.30 of the Site Plans specify 1- CULTEC Recharge 330 XLHD Chamber (TYP.) for each proposed house. The Memo from Dan Delany, P.E., Fuss & O Neill, dated February 21, 2012 to Doug McDonald, City of Northampton, regarding Village Hill Drainage Summary includes calculations that specify 2 CULTEC 330 XLHD infiltration units per lot. The Plans should be corrected to be consistent with the calculations specified in the Memo. 14.)Prior to issuance of a building permit for the second lot in the row of house lots numbered A3, 5, 7, 9, 11,13,15,17,19, maintenance and easements agreements for the alley way must be submitted to Office of Planning and Development for review and approval to be recorded. FINDINGS The Planning Board approved the site plan along with minor subdivision amendment that included relocation of driveways for the build out of the 24 lots along Moser Street at Village at State Hospital based on the plans submitted with this approval. This approval includes flexibility to build a minimum 8' width front porch or for porches fronting the full facade. Plans include: 1. "Village Hill Northampton Site Plan Approval Moser Street" Dated February 17, 2012 by Fuss & O'Neill for the Pecoy Group, Sturbridge Development LLC. Pages C0.00, C1, C1.1, C1.2, C1.3, C1.4, C2, C3, C3.01/02, L1, L2. 2. Custom Design Moser Street West Elevations for The Pecoy Group. Sheets A1-1 to A1-8, A2 -1 to A2 -8. 3. Memo by Fuss & O'Neill to Doug McDonald regarding Moser Street Subdivision Drainage and calculations. In approving the site plan, the Board determined that all the criteria in section 11 and criteria for the special permit originally adopted for the Planned Village, including design guidelines had been met. 1. The requested use protects adjoining premises against seriously detrimental uses. The new lots are part of the build -out of the state hospital and are consistent with those plans. 2. The requested use will not have an effect on convenience and safety of vehicular and pedestrian movement within the site and on adjacent streets, roads in the area. As part of the overall redevelopment of the state hospital, traffic mitigation will be made as previously GeoTMS® 2012 Des Lauriers Municipal Solutions, Inc. Planning - Decision City of Northampton Hearing No.: PLN- 2012 -0019 Date: March 29, 2012 APPLICATION TYPE: SUBMISSION DATE: PB Intermediate Site Plan 2/23/2012 Applicant's Name: Owner's Name: NAME: NAME: Sturbridge Development LLC MASS DEVELOPMENT ADDRESS: ADDRESS: 215 Baldwin Ave. 1350 MAIN ST Suite 110 TOWN: STATE: ZIP CODE: TOWN: STATE: ZIP CODE: WEST SPRINGFIELD MA 01089 SPRINGFIELD MA 01103 PHONE NO: FAX NO.: PHONE NO: FAX NO.: (413) 755 -1380 0 (413) 755 -1349 EMAIL ADDRESS: EMAIL ADDRESS: Site Information: Surveyor's Name: STREET NO.: SITE ZONING: COMPANY NAME' PRINCE ST PV(69) /RR(35) /FFR(35) /WP(24) /SG b(1) /SG a TOWN: ACTION TAKEN: ADDRESS: Notrthampton Ma MA 01060 Approved With Conditions MAP' BLOCK: LOT' MAP DATE: SECTION OF BYLAW: 31C 017 001 Chpt. 350- 11: Site Plan Approval TOWN: STATE ZIP CODE Book: Page: i 6925 302 PHONE NO FAX Na: EMAIL ADDRESS: NATURE OF PROPOSED WORK: Approval for development of 24 single family houses on lots 31C -23 through 34 and 38A- 128 -134, 38A- 136 -141. HARDSHIP' CONDITION OF APPROVAL. 1) Prior to issuance of the first certificate of occupancy for the project, a conservation restriction, to be held by the city on terms agreeable to the city, shall be recorded for the park allocated between lots A20 and A23. 2.)A pedestrian access sign at the curve where Moser meets Ford Crossing between Lots A20 & 23 and midblock between A11&13 indicating entry to the trap rock gravel public path within shall be installed prior to the marketing or construction of any of the lots along/ within the subdivision. 3.) The public easement and temporary path shall be granted for the path south of Lots A13 and A27 prior to the issuance of the first certificate of occupancy of the project. The easement shall be held by the city and terms drafted for this easement shall be approved by the city. 4.)The path segment between lots All & 13 shall be constructed as part of the construction on these lots and shall be completed prior to the issuance of the first certificate of occupancy for either one of these lots. 5.)The path design between lots A20 &23 shall be rough- constructed prior to the first certificate of occupancy of the project. 6.)The path segment across lot A27 shall be constructed prior to the first certificate of occupancy on lot A27. 7.)The applicant shall loam and re -seed the portion of the right -of -way by A14 where the driveway will be relocated. 8.)Tree to be relocated for lot 26A shall have a 1 year warranty from the time of issuance of certificate of occupancy for this lot. • 9.) Common Driveways for Tots A2 /A21 and A25 and A26 shall have easements recorded prior to issuance of a building permit for these lots. 10.) Common Driveways and new A14 driveway shall ramp up to sidewalk. Sidewalk shall not be covered with bituminous. The driveway should break for sidewalk. GeoTMS® 2012 Des Lauriers Municipal Solutions, Inc. o nto . iffsasariprsstts ,. DEPARTMENT OF BUILDING - INSPECTIONS 111 _ 212 Main Street ®-Municipal Building ,INSPECTOR Northampton, MA 01060 :1 _ _ — a 7 LOCA ON ( � 6 ige,s SQUARE FOOTAGE AMOUNT BASEMENT @ .20 7/5 1• ( , o a 1sTFLOOR @ .50 77, J / -a/ ✓n 217DFT.R 30 �.3 ( o �17 9,3a • Y2 FLOORS, FINISH ATTIC, GARAGE @ 20 7 4 57 DECK/PORCIIES @ .20 / 3 0, C� • TOTAL. /0.5 Za • • k ,,.,..), irL,,, ...,, ,..,,,,,, u):::„.:::.._, .‘,..,... ... :,....„ .,#,_,,,.,... . .: .. , .. .. : - ..: :. : ' .-..,...._. . i. ,,, -;i :..., 7 ,..: , - , ,. .: 7 ' , .. : -'1,' . . -i- _.'..,.. ; : ' .., ....._ . : ,.. — _ ,,,—:-.. : .-- ... 7 . - _•:_ii . :1• 777 :1 ----- ..._:: - . 7 .: -171: ..1.1:::::::T:1:1:-.:.:"--::::._;:-.".7::::::1,7,,-',-_,_.:,..7:.s.:i..1:;-:::...:11:::_,::.,1,,.......'. ri I . i . ___N-----_,,,,._ . .., .. k.„,: ! . . . ... , .. l - ' |' - Oil • • ul I Ezi, ,i i .. I ry ., LO T Al z ipuiii kr) ''''... ;\.:-..;,- ' ,h.-„ ,..'. ... „„„ . .....:.. ' .,' . ,, ,v ..,:- "• • L 221.50 6- CNI i iii 18 :17. , ; I 1j- " U.° MINN "-- IIIIIIIIiiiilL `�^ .�~. �.� `. • e -__-- __ _ '_ -� - _ °_ .- ° �_ - �_ -__. ^ _�,--^_.�� ._~~_ , ~ -____ .- .„.........._......_.__ ... ............___ QUICK ANALYSIS REPORT Date: August 21, 2012 Rating No.: 075 -12 Building Name: Rating Org.: Power House Energy Consulting Owner's Name: Phone No.: 413 - 835 -5162 Property: Lot #20 Moser St Raters Name: Matt Turcotte Address: Northampton, MA01060 Rater's No.: 1497133 Builder's Name: Pecoy Companies Weather Site: Northampton, MA Rating Type: Based On Plans File Name: 075 -12 Lot #20 Moser St plans 1296.blg Rating Date: 8/20/12 Codes Programs IECC 2009 Performance: Fails EPA ENERGY STAR 2.0 Fails IECC 2006 Performance: Passes EPA ENERGY STAR 2.5 Passes IECC 2004 Performance: Passes EPA ENERGY STAR 3.0 Fails IECC 2003 Performance: Passes Tax Credit Passes IECC 2001 Performance: Passes HERS Index 55 IECC 2000 Performance: Passes IECC 1998 Performance: Passes ECC of NY Performance: Passes l' 4, 0 Cell «c Q ECC of NV Performance: Fails ' I J MEC 1995 Performance: Passes (� _ ✓- woc ( ` S MEC 1993 Performance: Passes ' ` MEC 1992 Performance: Passes ASHRAE 90.2 Performance: Passes REM /Rate - Residential Energy Analysis and Rating Software v12.96 This information does not constitute any warranty of energy cost or savings. © 1985-2011 Architectural Energy Corporation, Boulder, Colorado. A c' °a a CERTIFICATE OF LIABILITY INSURANCE ° (mmot rrn ,l....-- 4/24,2012 THIS CERTIFICATE 1S ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POUCIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(8), AtITHORIgO REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the pdicy(ioa) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the pol icy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endotsement(s). PRODUCER tV61 Irene Saline """" �"" Alexander W Borawski Ino "Mil (4131586.5011 /�( Xing Street, Suite B ► , " +1UC.}0 -- WIZ46-7973 88 g i . , — , : ibaliseaborawtskjinsurance . COM IIISURFR1$) AFFORDING COVERAGE NMI Northampton MA 01060 -3257 KRUM Insurance 24171 MIRED tNStntERa :PeerlBBB Insurance 24198 Kent Pecoy & Sons Construction, Inc INISURmcMMss Employers Ins. Co. 215 Baldwin St , INSURER D : INSURER E: . West Springfield _ NA 01089 INSURER 1": COVERAGES CERTIFICATE NUMBER:cn REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT. TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN 18 SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. e R TYPE OF INSURANCE R 0 at .,1: ' A C 1! ►1 ►1 l.. Al f LIMITS ewe i GENERAL UMMITY EACH OCCURRENCE $ I, 000,000' X COMMERCAJ.GENERA.LIABILITY DAMAGE TO RENTED mmerrencej . $ 100,000 A Eli CLAIMSIMDE 1 X 1 OCCUR CBP8780556 7/1/2011 7/1/2012 MED EXPIAny 0A0 ram) $ 5,000 PERSONAL&Aw*limy $ 1, 000, 000 GENERAL AGGREGATE $ 2, 000, 00 0 GErn. AGGREGATE LIMIT APPLIES PER PRODUCTS - COMP/OP AOG S 2,000,000 X poucyj — i PIFr1.T I I LOC $ AuTOMO i QED [AMR $ 1000000 t3O04.Y INJ (Perpe son) $ $ � ALL OWNED 13 SCHEDULED RA/MUM 7/1/2011 1/1/2012 soDILY INJURY (Per uddent) $ AUTOS . PROPERTY DAMAGE HIRED AUTOS AUTOS O t' NIO 3 m Uncle ed mgbfBt O solo , $ ea II UMBRELU X m R EACH OCCURRENCE $ 5,000,000 B ■ EXCESS LIAB III cum; -MADE r AG EWE $ 5,000,000 1 ■ ,„ 3 ;.31 NT,* 3-0.00$ 7 2011 7/1/2012 $ o,0om 008783653 / / S ..._ C WORKERS COMPENeATtoN 1 1 im 1 EB AND EMPLOYED" MAMMY Y / N ANY OCCLUDED? n N r A E.1- EACH ACCIDENT $ 500,000 tM t 7.y In NM tECC2000239012011 6/30/2011 6/30/2012 EL. oisEASE. EA EMPLOYEE s 500, 000 DES( t OPERABotiSlwbw E.L. DISEASE - POLICYLWN' II 500,000 DESCRIPTION OF OPERATWNS 1 LOCATIONS /VESICLES (Attach ACORD 101, Addition( Remelts Schedule. If more space is req*e I) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POUCIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WtLI. BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. City of Northampton 212 Main Street AUTHORIZED REPRESENTATIVE Northampton, MA 01060 R Borawski /BORIBI 1 29 '~ 'e c ACORD 25 ( 010105) OP ACORD CORPORATION. All rights reserved. EN.S025 tom m!ct The A.P.ro11 name anti innn two nomIntati m rasrke of Annan • I SECTION 8 - CONSTRUCTION SERVICES 8.1 Licensed Construction r SSupervisor: Not Applicable ❑ Name of License Holder : �c f /ti-f /k t � S S 9 License Number ( -)/5 - .>i" 4rEf I), 5,6',Q//� 2 �,rt -6 . ,M , o 6 V i�� ��3 Address Expiration Sign re Telephone 9. Registered Home Improvement Contractor. Not Applicable ❑ L('7 /T'cc >/ , , :Scll , S (r,1, t1( l/a &U .i/vcc , /C 7367 Company Name Registration Number 0 / //c-,)t. JiIJ SIP 5 Ai, S /ehtf6 A a 414. dit 9 7 ,,,i / 3/ /, c -�z Address Expira i ate Telephone /' 757 • RI t SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes No ❑ 11. - Home Owner Exemption The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature I SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) New House ® Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors 0 Accessory Bldg. El Demolition ❑ New Signs [0] Decks [p Siding [0] Other [0] Brief Description of Proposed Work: /Lici -4/ /03/..,a , S/ :4 4 btl Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll - Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family i/ Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? lE S S / A . 3 - d. Proposed Square footage of new construction. /9 /`I Dimensions / S / el. ' lei ct i. cA'/ e rte - it c / • p ,', i? c d e. Number of stories? 9 f. Method of heating ? / /1S / %iii Fe ei 6 i/ 1 /Ilk Fireplaces or Woodstoves / Number of each g. Energy Conservation Compliance. 1/4 Masscheck Energy Compliance form attached? 1 c -S h. Type of construction & &1 cz) /%lZ4fi1( Cot z A 7,41- i. Is construction within 100 ft. of wetlands? Yes ✓ No. Is construction within 100 yr. floodplain Yes 4o j. Depth of basement or cellar floor below finished grade `7 k. Will building conform to the Building and Zoning regulations? ✓ Yes No . I. Septic Tank City Sewer ✓ Private well City water Supply SECTION 7a - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, /6 / / , as Owner of the subject property hereby authorize c>>Cti' Ct 4i2+: to act on my behalf, in all matt relative to work authorized by this building permit application. --- Zeij %? Signature of Owner Date , I, k r '- a , as Owner /Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signe .under th •airls and penalties of perjury. Print Name r -- / i Signature of Owner /Agent -- Date ‘r . . , ' S f-_'._ iii.) ) 7 Section 4. ZONING Alt Information Must Be Completed. Permit Can Be Denied Due To Incomptete Information Existing Proposed Required Zoning ` This column mbofilled in by Building Department -- --------------� r -----------'--- Lot Size '._______-_-___-_' �-__ '_- _-� L_--___-__ _J __| Front �----------------/ -- ^ ` Frontage Setbacks Front �-� �—1 r------, �__'� � L.__J Side L: F---� }t[_l L r- _ R: r---] F---- [ --| r-� r--7 � -- Rear L. -' �_�__� �___ : Building Height ---.... F [--| _ _____ _ Bldg. Square Footage [-- 1 --- % F-- �-� �-- �� ����� ��_�� ���� Open Space Footagn % (uumnum�mbmompwou F F-- [---- �- -- |----| parking) F-- �—� #ofPucki F-- o�S�u000 �---- ^- L___ _1 Fill: [ -- - ' ' - - - �--- r - - - -- -' , (volumo& Location) [_____ __IL_ ,____________J1 ______1 A. Has a Special Permit/Variance/Finding ever been issued for/on the site? / NO ® DONT KNOW 0 YES 0 r ----------- 1 IF YES, date issued:' J IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT YES ��` �� KNOW �� r ------ ---- [------- IF YES: e nter Book Page! | and/or Document ! ' { . _,/ �� �� �� B. Does the site contain a brook, body ofvvaterorvvetiands7 NO «�� DONT KNOW «�� YES �~� IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained Date | «�� �~� , Issued: [__-_'__-___/ C. Do any signs exist on the property �� �� V YES x�� NO �,� _ ._ ������������`��������������������������� IF YES, describe size, type and Location: 1 | ,_________________________________________/ D. Are there any p changes to or additions of signs intended for the property ? YES 0 NO 0 _ _�___ ���_________�______________'_ ____ __ IF YES, describe size, type and location: 1 | _I E. WiII the construction activity disturb ring, gradingexcavation, ur filling) over 1 acre orisb part ufa common plan that will disturb over 1 acre? YES � NO K � �� �� IF YES, then a Northampton Storm Water Management Permit from the DPW is required. C ` , , Department use only City of Northampton Status of Permit Building Department Curb,Cut/Driveway Permit ■ 212 Main Street 'Sews? /Septic :A�ailabillty Room 100 Water/WellAvallability hkjG ?OZ p rt ham ton, MA 01060 Two .Sets of Structural. Puns phone 41 - 587 -1240 Fax 413 - 587 -1272 Plot/Site-Plans Other? Specify IPFC TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE INFORMATION 1.1 f /i z j This section to be completed by office .1 Property Address: i// /�, //!! a 0 Ma p c3 /6∎ L ( Unit /Alf ,4), .vv Zone Overlay District /() ©di#4 P' /1414 () /DL D Elm St. District CB District SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: /�� iefH /} / t 1 Cry (' lS rtAig7ie, le /rt d ce5'. j/j �.ST�C t -E 7 Id, Name (Print) �� Current Mailing Address: " _ 37 " 7oe Telephone Signature 2.2 Authorized Assent: ci 2) ;C/ 17 2 d15 di `S1/ 11 %. SMA-' E.(aJ 44,4. Name ( • t� Current Mailing Address: Sig ature Telephone SECTION 3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building (a) Building Permit Fee /u1,CCO 2. Electrical (b) Estimated Total Cost of /t9, 6C6 Construction from (6) 3. Plumbing Building Permit Fee 1. cc'C 4. Mechanical (HVAC) /d.. , c 5. Fire Protection ;;? .t 6. Total= (1 +2 +3 +4 +5) ;O,€ Check Number itfO p14G This Section For Official Use Only Permit Number: Date Building Issued: Signature: Building Commissioner /Inspector of Buildings Date File # BP- 2013 -0195 APPLICANT /CONTACT PERSON KENT PECOY & SONS CONSTRUCTION INC ADDRESS/PHONE 215 BALDWIN ST WEST SPRINGFIELD (413) 781 -7008 PROPERTY LOCATION 124 MOSER ST - LOT A20 MAP 31C PARCEL 027 001 ZONE PV V ° THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out ,1 ' Fee Paid Typeof Construction: CONSTRUCT 2 STORY SF W /ATT GARAGE/PORCH New Construction Non Structural interior renovations Addition to Existing_ Accessory Structure Building Plans Included: Owner/ Statement or License 052589 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF9RMATION PRESENTED: Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management D- col ay 00, ,. Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. 124 MOSER ST - LOT A20 BP- 2013 -0195 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 31C - 027 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: New Single Family House BUILDING PERMIT Permit # BP- 2013 -0195 Project # JS- 2013- 000317 Est. Cost: $220000.00 Fee: $1057.20 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: KENT PECOY & SONS CONSTRUCTION INC 052589 Lot Size(sq. ft.): 5333.60 Owner: KENT PECOY & SONS CONSTRUCTION INC Zoning: PV Applicant: KENT PECOY & SONS CONSTRUCTION INC AT: 124 MOSER ST - LOT A20 Applicant Address: Phone: Insurance: 215 BALDWIN ST (413) 781 -7008 WEST SPRINGFIELDMA01089 ISSUED ON:9/6/2012 0:00:00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT 2 STORY SFH W /ATT GARAGE /PORCH POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 9/6/2012 0:00:00 $1057.20 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner