24C-042 II I 5 IN ://A. 912.5 - Height and areas Not applicable. The partial change of occupancy results in a change to an equal hazard category, therefore, the existing height and area of the existing building is deemed acceptable, according to Section 912.5.2. 912.6 - Exterior wall fire - resistance ratings The partial change of occupancy results in a change to an equal hazard category, therefore, the existing exterior wall ratings, including openings, of the existing building is deemed acceptable, according to Section 912.6.2. 912.7 - Enclosure of vertical shafts Not applicable. The area of the building proposed for a partial change of occupancy is located on the ground floor. 912.8 - Accessibility None of the existing accessible elements will be altered and any new elements, will comply with the requirements of 521 CMR. End of Code Review Northampton High School Black Box Theater - PERMIT SET 7 of 6 SECTION 905 - MEANS OF EGRESS 905.1 - General Means of egress in the portion of the building undergoing a change of occupancy classification will comply with Section 912. SECTION 906 - ACCESSIBILITY 906.1 - General Accessibility in the portion of the building undergoing a change of occupancy classification will comply with Section 912.8. SECTION 907 - STRUCTURAL 907.1 - Gravity loads Not applicable. No gravity elements will be altered. 907.2 - Snow and wind loads Not applicable. The partial change in occupancy classification does not result in a higher wind or snow occupancy category, according to Table 1604.5. 907.3 - Seismic loads Not applicable. The partial change in occupancy classification does not result in an increase in the hazard index of the occupancy category, according to Table 1604.5. 907.4 - Access to Occupancy Category IV Not applicable. The partial change in occupancy does not require compliance with Section 907.3.1, nor is the building assigned to Occupancy Category IV. SECTION 909 - MECHANICAL 909.1 - Mechanical requirements The new occupancy of the existing building will comply with increased mechanical ventilation requirements in accordance with the International Mechanical Code. See Section 709. SECTION 911 - OTHER REQUIREMENTS 911.1 - Light and ventilation Light and ventilation will comply with the requirements of this section for the new occupancy. SECTION 912 - CHANGE OF OCCUPANCY CLASSIFICATION 912.1 - General The partial change of occupancy classification requires that the building conform to the provisions of Section 912. 912.2 - Fire protection systems An automatic fire sprinkler system is provided throughout the building, including the area where the partial change of occupancy occurs. The existing fire protection systems will not be altered. 912.3 - Interior finish The interior finish of walls and ceilings will comply with the requirements of the International Building Code in areas of the building undergoing the partial change of occupancy classification. 912.4 - Means of egress, general The partial change of occupancy classification does not result in an increase in the means of egress hazard category, according to Table 912.4. Existing elements of the means of egress will comply with the requirements of section 805 for the new occupancy classification. Northampton High School Black Box Theater - PERMIT SET 6 of 6 709.3 - Local exhaust There will be no newly introduced devices, equipment, or operations within this space. SECTION 711 - ENERGY CONSERVATION 711.1 - Minimum requirements Level 2 alterations to the existing building will conform to the energy requirements of the International Energy Conservation Code as they relate to new construction only. Chanter 9 (IEBC with Massachusetts Amendments) Work Area Compliance Method - Change of Occupancy SECTION 901 - GENERAL 901.1 - Scope Per 303, exception 4. This type of small theater space or assembly space within Use Group E is considered an Assembly space that is an accessory to Group E and is not considered a change in occupancy. 901.2 - Change in occupancy with no change of occupancy classification Not applicable. The change of occupancy results in a partial change in classification. 901.3 - Change of occupancy classification The partial change of occupancy classification will result in conformance to the provisions of Sections 902 through 912. 901.4 - Certificate of occupancy required A new certificate of occupancy will be issued as a result of the partial change of occupancy. SECTION 902 - SPECIAL USE AND OCCUPANCY 902.1 - Compliance with the building code Not applicable. The building will not be occupied for special use or the occupancy categories outlined in this section. 902.2 - Underground building Not applicable. The building is above ground. SECTION 903 - BUILDING ELEMENTS AND MATERIALS 903.1 - General Building elements and materials in the portion of the building undergoing a change of occupancy classification will comply with Section 912. SECTION 904 - FIRE PROTECTION 904.1 - General The building will conform to the fire protection requirements of Section 912. Northampton High School Black Box Theater - PERMIT SET 5 of 6 SECTION 705 - MEANS OF EGRESS 705.1 - Scope The requirements of this section apply to the work area proposed for Level 2 alterations, and will be applied throughout the floor on which the work area is located, where specified. 705.2 - General The means of egress will comply with the requirements of this section. 705.3 - Number of exits The number of exits in the work area will be in accordance with Sections 705.3.1 through 705.3. 705.4 - Egress doorways Egress doorways in the work area will comply with Sections 705.4.1 through 705.4.5. Two egress doorways will be provided in any work area room or space having an occupant load greater than 50 or in which the travel distance to an exit exceeds 75 feet. There are two existing egress doors in this space. 705.5 - Openings in corridor walls Not applicable - there are no changes to walls and or openings into corridors. SECTION 706 - ACCESSIBILITY 706.1 - General The building, with any facility or element altered, will comply with the requirements of 521 CMR. No existing egress, ramp, or accessible feature will be altered. The existing space meets accessibility requirements and the newly configured space will meet the accessibility requirements of 512 CMR. Section 14.2 of 521 CMR: AAB required accessible seats for areas with fixed seating. The Black Box Theater will have 38 fixed seats and therefore requires 2 wheelchair spaces per the chart in section 14.2. See floor plan for proposed locations of spaces. Note the spaces will be provided in an area which utilizes stacking chairs and so can accommodate more than two accessible spaces is necessary. SECTION 707 - STRUCTURAL 707.1 - General There will be no alterations to the existing structural systems or elements. 707.2 - New structural members Not Applicable. No new structural members will be added. 707.3 - Minimum design loads The alterations to this space will not increase or alter the design loads of this space or portion of the building 707.4 - Existing structural elements carrying gravity loads Not applicable. No structural elements carrying gravity loads will be altered or added. 707.5 - Existing structural elements resisting lateral loads Not applicable. No structural elements resisting lateral loads will be altered or added. 707.6 - Voluntary lateral- force - resisting system alterations Not applicable. No lateral force - resisting systems will be altered or added. SECTION 709 - MECHANICAL 709.1 - General All reconfigured or converted spaces intended for occupancy will be provided with natural or mechanical ventilation in accordance with the International Mechanical Code. The existing space is mechanically ventilated. 709.2 - Altered existing systems Existing mechanical ventilation systems will not be altered, reconfigured, or extended. Northampton High School Black Box Theater - PERMIT SET 4 of 6 EXISTING BUILDING CODE REVIEW Chapter 7 (IEBC with Massachusetts Amendments) Work Area Compliance Method - Alterations Level 2 SECTION 701 - GENERAL 701.1 - Scope Level 2 alterations, repairs and changes in occupancy of the existing structure will comply with the provisions of Section 101.5.2 - Work Area Compliance Method. 701.2 - Alterations Level 2 compliance All work will comply with the requirements of Chapter 6, in addition to the requirements of this section. 701.3 - Compliance All new or replacement materials will comply with the requirements of this section. SECTION 702 - SPECIAL USE AND OCCUPANCY 702.1 - General Not Applicable. The existing building is not classified as special use and occupancy. SECTION 703 - BUILDING ELEMENTS AND MATERIALS 703.1 - Scope Alterations to the existing structure, including the addition of seating riser platforms, new flooring, new lighting pipes, and associated electrical work, will comply with the work area requirements of Level 2 alterations. 703.2 - Vertical openings Not applicable. The work area is contained within a single story area of the building. 703.3 - Smoke barriers Not applicable. The building is not classified for Group 1 - 2 occupancy. 703.4 - Interior finish The interior finish (paint) of walls and ceilings in exits and corridors in the work area will comply with the requirements of this section Class "B" for exit passageways, and Class "C" for rooms and enclosed spaces per table 803.9 of the IBC. 703.5 - Guards The proposed riser platforms will be less than 30" above the floor. A 36" high guard will be provided. Alterations will comply with the requirements of Sections 703.5.1 and 703.5.2. SECTION 704 - FIRE PROTECTION 704.1 - Scope Work areas in which Level 2 alterations are being performed, and where specified, throughout the floor on which the work areas are located, will conform to the requirements of this section. 704.2 - Automatic sprinkler systems There is an automatic sprinkler system within this building and space. No alterations to this space will conflict with the existing sprinkler system. 704.3 - Standpipes Not applicable. 704.4 - Fire alarm 6z detection There will be no alterations to the existing fire alarm system. Northampton High School Black Box Theater - PERMIT SET 3 of 6 805.1.1 Subfloor construction. Floor sleepers, bucks and nailing blocks shall not be constructed of combustible materials, unless the space between the fire - resistance -rated floor assembly and the flooring is either solidly filled with noncombustible materials or fireblocked in accordance with Section 717, and provided that such open spaces shall not extend under or through permanent partitions or walls. 805.1.2 Wood finish flooring. Wood finish flooring is permitted to be attached directly to the embedded or fireblocked wood sleepers and shall be permitted where cemented directly to the top surface of fire - resistance -rated floor assemblies or directly to a wood subfloor attached to sleepers as provided for in Section 805.1.1. 805.1.3 Insulating boards. No applicable. OCCUPANCY LOAD: Per table 1004.1.1 Assembly areas with concentrated chairs shall have a maximum occupancy of 7Net SF per person. This would allow for a maximum of 187 occupants within this space. The reality is that a significant portion of the space is "backstage" and "stage" space. The maximum audience space seating will allow for 76 seats, see floor plan for seating layout. The maximum production staff in this space will likely be no more than 20, for a total real occupancy of 96 during a production. This space will mostly be used for theater classes with a much smaller occupancy. EGRESS: • Per section 1021, the number of exits required from this space is 2 as there are more than 50 and less than 500 occupants. • Section 1028 Assembly Egress: 1028.2 notes that an Assembly space that is an accessory to Use Group E with an occupant load greater than 300 is required to have a main egress. The occupant load is less than 300 and does not require a main egress. • Section1028.6.1 notes that the minimum width of a means of egress must be .3" plus.075" per occupant, which equal a minimum of 30 ". (Per MAAB, minimum egress must be 36 ". Existing Egress doors are 36 ") • 1028.7 Notes that the maximum travel distance to an egress shall not exceed 200 feet. The two egress doors are less than 200' from any point in the space. • 1028.9 Notes that Assembly Aisles must be a minimum of 36 ". The aisles on the platforms or between any seating will be a minimum of 36 ". • 1028.10 Notes that the width of Aisles at rows of seating that contain 14 or less seats shall be a minimum of 12 ". The platforms are 36" deep and with the seat, which allow for a 12" aisle with the seating in place. • 1028.11 Notes that the tread at the platform seating shall have a contrasting marking stripe of 1" to 2" in depth marking the edge. • 1028.12 Notes that secured seating is required with 200 or more seats. There is a maximum of 76 seats and a portion of these will be fixed. • 1008.1.10 required panic hardware on doors serving a space with an occupancy load of 50 or more. Panic hardware will be added to the two existing egress doors as shown on the floor plan. Northampton High School Black Box Theater - PERMIT SET 2 of 6 NORTHAMPTON HIGH SCHOOL - BLACK BOX THEATER EXISTING BUILDING CODE REVIEW WORK AREA COMPLIANCE METHOD 8 August 2012 - PERMIT SET SCOPE OF WORK: Minor modifications to a single classroom of an existing education building, the Northampton High School, Northampton, MA. Modifications will provide an accessory theater space, the Black Box Theater. The proposed theater space will occupy what were originally designed to be an aerobics room and an adjacent athletic storage room. The former storage room is currently used as a wardrobe room. These two spaces were part of an addition that was built in 1998. The theater department wishes to make improvements to allow small student theatrical performances to take place there. The space will be used mostly as a classroom and occasionally for audience performances. The space, designated on the original 1998 plans as `Aerobics', occupies 1,305 square feet. The adjacent space used for wardrobe storage occupies 405 square feet. The building has modern fire protection, alarms, exit signs and emergency lighting, dating from the renovations and expansion done in the late '90s. The modifications are primarily finish changes. There are no changes to existing doors or partition walls and there are no exterior windows in this space. The modifications include the addition of wood riser platforms for seating. Some seating will be fixed to the platforms while other seats will be moveable - see the floor plan for seating locations and quantities. Proposed seating is for a total of 76 persons. Fire rated theater curtains will be provided to create a back stage. Six metal lighting pipes, dimmer boxes, and quad outlets will be installed allowing for adjustable theater lighting. A new theater floor with transition strips will be provided. USE GROUPS & TYPES OF CONSTRUCTION: The portion of the building containing the proposed Black Box Theater was last renovated in 1999. The architect of that renovation, Kaestle Boos & Associates, has provided us with their Code sheet dated 15 December 1998. This Code sheet classifies this portion of the building as a primary use of "E" with a secondary use of "A -3 ". The construction type is 2C, non- combustible (6th ed. MA State Building Code). A 2 -hour fire wall between this area of the building and the adjacent areas to the west is shown on the KBA Code sheet. Although a theater space is considered an A -1 Assembly space, there is an exception under 303, exception 4. noting a theater can be considered an accessory to Use Group E. Therefore the alterations to this space are not considered a change in use group. It is intended that the risers for the fixed and moveable seating be constructed of plywood on dimensional lumber framing. 603.1 Allowable Materials: Combustible materials shall be permitted in buildings of Type 1 or II construction in the following applications and in accordance with Sections 603.1.1 through 603.1.3: 9. Finish flooring installed in accordance with Section 805. Section 805.0 in turn states: 805.1 Application. Combustible materials installed on or embedded in floors of buildings of Type I or II construction shall comply with Sections 805.1.1 through 805.1.3. Northampton High School Black Box Theater - PERMIT SET 1 of 6 The Commonwealth of Massathusetts - _ Department of Industrial Accidents Office of Investigations ' 600 Washington Street Boston, MA 02111 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders / Contractors /Electricians/PIumbers Applicant Information Please Print Legibly Name ( Business /Organization/Individual): 9 11 • t, it l _ Address: - 70 (lest so (oe City /State /Zip: idd r s+ r 1215. ti A Phone #: I- /13 " XasE Are you an employer? Check the appropriate box: Type of project (required): 1. ❑ I am a employer with 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub - contractors 6. ❑New construction 214 I am a sole proprietor or partner- Iisted on the attached sheet. 7. Remodeling ship and have no employees These sub- contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.- required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions officers have their 11. Plumbing repairs or additions 3. ❑ I am a homeowner doing all work ave exercised ❑ myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, § 1(4), and we have no employees. [No workers' 13.0 Other comp. insurance required.] 1 1 *Any applicant that checks box #1 must also fill out the section below showing their workers' compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. Contractors that check this box must attached an additional sheet showing the name of the sub- contractors and state whether or not those entities have employees. If the sub - contractors have employees, they must provide their workers' comp. policy number. I am an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy # or Self -ins. Lic. #: Expiration Date: Job Site Address: City /State /Zip: Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one -year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby cer i under the pains and penalties of perjury that the information provided above is true and correct 't ' Signature: ' ..: Date: *6/0 Phone #: 515 as' Official use only. Do not write in this area, to be completed by city or town official City or Town: Permit/License # Issuing Authority (circle one): 1. Board of Health 2. Building Department 3. City /Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone #: Versionl.7 Commercial Building Permit May 15, 2000 SECTION 10- STRUCTURAL PEER REVIEW (780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required . Yes 0 No •3 SECTION 11 - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT . W.. _ _ _ , as Owner of the subject property act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner .— _�..�__.,.�......._._.___ ._._. _..__ , as Owner /Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties ofser'ur r Print Name Signature of Owner /Agent Date SECTION 12 - CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder . License Number _ ..w 55� ar a IAA 0/0(C lo ? s .. + Sb_. Add- ; Expiration Date V.Iff 16. i13 s?saas' 313, /a ©3 Signature Telephone SECTION 13 - WORKERS':'COMPENSATION INSURANCE AFFIDAVIT (M "G.L. c: 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes Pit No Version1.7 Commercial Building Permit May 15, 2000 J SECTION 9- PROFESSIONAL DESIGN'AND CONSTRUCTION - FOR BUILDINGS-AND STRUCTURES SUBJECT TO • CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116 (CONTAINING MORE THAN 35,000 C.F. OF EIJ,FLOSED SPACE) . 9.1 Registered Architect: ____ . Not Applicable ❑ Name (Registrant): µ — —:_ --- i jj�� Registration Number 5 Expiration ate • ign tune Telephone 9.2 Registered Professional - gineer(s): Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address - R�istration Number M Signature Telephone Expiration Date Name Area of Responsibility 1 Address Registration Number } Signature Telephone Expiration Date —_ „, _. Name .. --._ _. "— Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor Not Applicable Company Name: _ Responsible In Charge of Construction Address__ 1 Signature Telephone Version1.7 Commercial Building Permit May 15, 2000 8. NORTHAMPTON. ZONING Existing Proposed Required by Zoning , This column to filled in by Building Department Lot Size ....__._,., Frontage Setbacks Front Side • L:--- _ R : — Rear Building Height Bldg. Square Footage Open Space Footage (Lot area minus bldg & paved -.._ ". w parking) # of Parking Spaces Fill: _.._._�.__._....._ ,.. _.,.._ ...._.._� _..__, -_.. ._..� __.,..._ _.�..... (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO 0 DONT KNOW YES 0 IF. YES, date issued: IF YES: Was the permit recorded at the Reg' try of Deeds? NO 0 DONT KNOW ® YES 0 IF YES: enter Book ` Page. and /or Document #' B. Does the site contain a brook, body of water or wetlands? NO 0 DONT KNOW YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained 0 , Date Issued C. Do any signs exist on the property? YES A® NO 0 IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES Q NO �+ IF YES, then a Northampton Storm Water Management Permit from the DPW is required. 4 Version1.7 Commercial Building Permit May 15, 2000 SECTION 4 CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 ' Y CUBIC FEET OF ENCLOSED SPACE .rr. Interior Alterations ❑ Existing Wall Signs ❑ Demolition ❑ Repairs ❑ Additions ❑ Accessory Building ❑" R+ Exterior Alteration ❑ Existing Ground Sign ❑ New Signs ❑ Roofing ❑ Change of Use ❑ Other ❑ d Brief Description Enter a brief description here. Of Proposed Work: ti 14r 1 i ri'' °``S tO acv >c , nsrti u _m_. I __. . , 5 11 . _e`t�_ __. .. _____ . ._ SECTION.5 - USE GROUP AND CONSTRUCTION TYPE . USE GROUP (Check as applicable) CONSTRUCTION TYPE A Assembly A -1 ❑ A -2 ❑ A -3 1A I ❑ A-4 ❑ A -5 ❑ 7 f.i,dl--\944.1 1B ❑ B Business ❑ 2A ❑ E Educational Nli.. 2B .„ r 0 F Factory ❑ F -1 M L_I F -2 ❑ 2C 24 H High Hazard ❑ 3A ❑ 1 Institutional ❑ 1 -1 ❑ I -2 ❑ 1 -3 ❑ 3B ❑ M Mercantile ❑ 4 ❑ R Residential ❑ R -1 ❑ R -2 ❑ R -3 ❑ 5A ❑ S Storage ❑ S -1 0 S -2 ❑ 5B 1 ❑ U Utility ❑ Specify: ____. ._..._...... _._..w__.�... ._.. _.._______..V. M Mixed Use ❑ Specify S Special Use ❑ Specify COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS, ADDITIONS AND /OR CHANGE IN USE Existing Use Group L, °i ,__, Proposed Use Group: 17 -- .. Existing Hazard Index 780 CMR 34): __,_ Proposed Hazard Index 780 CMR 34): ______________ ___.. _._, SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor (sf) O C' "" t... E 1 st F — 1 !. _., 2nd ...... ..,_._ ,.._.._. __. 2nd __ w 3 .w. Total Area (sf) Total Proposed New Construction (sq__._..., Total Height (ft) Total Height ft 7. Water Supply (M.G.L. c. 40, § 54) 7.1 Flood Zone information: 7.3 Sewage Disposal System: Public ❑ Private 0 Zone ___ _ ,,,, w Outside Flood Zone❑ Municipal ❑ On site disposal system I:1 e e Version1.7 Commercial Building Permit May 15, 2000 t a� � s f� 0 a � w r �a i City of Northampton s ' � �� � g �� � i �,°^' - i ; . B u ildi ng D epa rt men t c' t/D re ' F enn ' � �` z a � < ,�-- ��--- 212 Main Street 5 'ewei 4.4aira6 tt ,t s �' Q 24 \ � Room 100 �W e Rff A.,0 iility � - r PSG, ': Northampton, MA 01060 T ® t a9 � a � n f5 t c �l , .. . . $. 1 a'�� v'� TAE Ft, p; 13- 587 -1240 Fax 413 - 587 -1272 Plot/Ste Plans !:JF N > Ottrer p - eetfy 1\ PIE ‘.4c\' TO CONSTRUCT, REPAIR, RENOVATE, CHANGE THE USE OR OCCUPANCY OF, OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE INFORMATION 1.1 Property Address: s This section to be completed by office 3 ° E r S'rpQ" ; Map Lot Unit nIO ►R / /1 A r Zone Overlay District .,..--_.A. ....... ,.m . _.--...,..- ,....w BIM St. District CB District 1 SECTION 2- 'PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: ' - C - 4:: - --p-:Vo-_A---f=--------- „ Name (Print) , L - Current Mailing Address: 74.,,,,e) Signature "13i��� %" Telephone 2.2 Authorized Agent: Name (Print) Current Mailing_Address: i+ 0 / . , q /3 - S75- .3-5 Signature idy.•r ' • ' i/"Q Telephone SECTION 3 - ESTIMATED C® TRUCTION CO Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building 7 7 goo _ .( B,LJiidin Permit Fee 2. Electrical ___... __ (b) Estimated Total Cost of Construction from S6) . ,._ .._.....__ . _ �_ 3. Plumbing —_..m___.._____ ------ Building Permit Fee 4. Mechanical (HVAC) ..... ._.__....._._._..._._.___.., _ _. 5. Fire Protection ....__....! 6. Total = (1 + 2 + 3 + 4 + 5) Check, Number V This, Section For Official Use Only Building Permit Number Date . 'issued Signature: Building Commissioner /Inspector of Buildings Date *Am - lo ►t t E File # BP- 2013 -0157 Or, To 1 sS i,6 w f) APPLICANT /CONTACT PERSON STEVEN ZUCCHINO ADDRESS /PHONE 70 Gleason Road NORTHAMPTON (413) 584 -3878 Co RJa. a (0 N4' PROPERTY LOCATION 380 ELM ST - NORTHAMPTON HIGH SCHOOL V MAP 24C PARCEL 042 001 ZONE URB(100)/WP(26)/ Ql® 10(0/ o THIS SECTION FOR OFFICIAL USE ONLY: U" ( PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE (.J 6\ ''' ZONING FORM FILLED OUT f 0 Fee Paid O 4' Building Permit Filled out .-O Fee Paid \‘13\\I„? Typeof Construction: RENOVATE AEROBI S ROOM TO THEATER `3 New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: O w ne r/ Statement or 021356 3 s of Plans / Plot Plan T H�L L OWING ACTION License HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF ATION PRESENTED: Ap proved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management Demolition Delay C:7---- OF n i 3 Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. A 380 ELM ST - NORTHAMPTON HIGH SCHOOL BP- 2013 -0157 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 24C - 042 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: renovation BUILDING PERMIT Permit # BP- 2013 -0157 Project # JS- 2013- 000255 Est. Cost: $7800.00 Fee: $0.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: STEVEN ZUCCHINO 021356 Lot Size(so. ft.): 1087257.60 Owner: NORTHAMPTON CITY OF NORTHAMPTON HIGH SCHOOL Zoning: URB(100)/WP(26)/ Applicant: STEVEN ZUCCHINO AT: 380 ELM ST - NORTHAMPTON HIGH SCHOOL Applicant Address: Phone: Insurance: 70 Gleason Road (413) 584 -3878 NORTHAMPTONMA01060 ISSUED ON:8/14/2012 0:00:00 TO PERFORM THE FOLLOWING WORK: RENOVATE AEROBICS ROOM TO THEATER POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 8/14/2012 0:00:00 $0.00 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner