Loading...
06-064 (7) barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99% of the moisture in a structure. This is evident every time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 26. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 27. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note: ThruLoks are engineered for post attachment supporting a railing. 28. Smoke and CO detectors as required. 780 CMR R314 and R315. 29. Closets beneath stair which have doors must be drywalled with % ". 780 CMR R302.7 Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. My email address is: lhasbrouck Thank you for your cooperation on these matters. Louis Hasbrouck City of Northampton Building Commissioner 11. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basements, 6'4" at beams /ducts. 780 CMR R305.1. MA amended 12. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4 13. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. Order restrictors. 780 CMR R612.2 14. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape. 780 CMR R310 b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft at 1 floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 3/4" from the top of the threshold and only in- swinging doors. 780 CMR R311.3 15. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ", maximum riser 8 maximum overall variance for the run is 3/8 ", 4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception, 4 3/8" on balustrade, 6" in the triangle. Graspable rail 1 %" minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 16. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36 ", 4" sphere rule. 780 CMR R312.1. 17. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In interior non - bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1 %2 16ga. strap must extend a minimum of 6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom. Notches are different. 18. Dryer duct transition is limited to 8' of aluminum flex and must be exposed. 780 CMR M1502.4.3 19. Dryer duct maximum equivalent length is 25' or per manufacturer's specs. 780 CMR M1502.4.4.1, no screwed connections. 20. Markup air is required for any exhaust hood of 400 CFM or more. 780 CMR M1503.4 21. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5' from the duct outlet for all fireplaces 22. Fire and draft stopping shall be completed before rough inspection. 780 CMR R302. 23. Ignition barriers in place before final. 780 CMR R316. 24. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA and 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. Energy information including mechanical equipment posted on the electric panel. d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Building Option Package. 25. Vapor retarders. Although these are still in the code there are exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer (diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air City of Northampton Massachusetts w w.1 DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building JF Northampton, MA 01060 INSPECTOR Ed Jazab July 31, 2012 9 Shepherds Hollow Leeds, MA 01053 Subject Location: 62 Chestnut Ave Ext. unit #22 Map Block: 06 -064 Mr. Mr Jazab, These are some additional items that are needed: 1. Truss, LVL and I -joist engineering 2. Thermal Bypass Checklist, Initial HERS and final HERS ratings, Energy and equipment info posted on the electric panel. 3. Heat loss calculations, room by room with equipment sizing 4. Final electronic or hard copy plan showing field changes. Footings, foundation, beams, ECT. 5. Plans showing all roof leaders into dry wells 6. Smoke and Carbon Monoxide detector locations 7. Foundation plans meeting current Mass code requirements 8. Locations of basement means of egress and emergency escape openings 9. As of August 4 2011 the 8 Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8 Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I soils (table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. 5. Ceiling joist are intended to prevent spread, once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8 -16nd common are required at each connection. 780 CMR R802.3.1. 6. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1 / 3rd 780 CMR R802.3.1 7. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 8. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and number of jack studs required. 9. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss 10. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. b. All corners must be appropriately attached to the foundation. Qs tKA p1. o _ . ;4t J r+ 9L. ' �- �- � DEPARTMENT OF BUILDING 'INSPECTIONS A � _ °� 212 Main Street i Mimicigal Bui1i ing ;INSPECTOR . lot Northampton, MA 01060 • • LOCATION ,./4 G EST N V :k ik\►{ f K NS to rJ SQUARE FOOTAGE AMOUNT BASEMEN! @ =20 ( 6 '2 j - )25- 2.1) fFLOOR @ .50 16,9 g ran 2 FIR @:30 • S . Yz FLOORS, FJNISH ATTIC, GARAGE @ 20 LI 2— 3 S t q 0 • DECKJPORCHES @ . 20 0 ( 647' TOTAL. § 13 �C -, 3© . • • • • Stretch Code & Utilitiy Incentives Compliance Specifications Builder: u Patrick Melnik HERS Index: 63 bgte oN pa 60 G Re C Project Address: Lot #22 Beaver Brook UDRH: 32.8% better than MA reference home r ct s e eA Northampton, MA 01060 fir /► e1 t The Massachusetts Stretch Energy Code and the MA New Homes with Energy Star program require a Home Energy Rating for compliance. Your preliminary Home Energy Rating shows that the project will meet the HERS Index requirement of both programs, provided that you meet or exceed the specifications listed below. In addition to your Rating, your project must meet specific mandatory requirements as outlined in the Thermal Enclosure Checklist and the 2009 IECC. Please ask your HERS Rater and your building code official for information about meeting all of the requirements. Building Envelope Conditioned Floor Area 1620 square ft Volume 25525 cubic ft Foundation Walls R18 (3" closed -cell spray foam) Slab uninsulated Framed Floors none Rim & Band Joists R18 (3" closed -cell spray foam) Exterior Walls R20 (5.5" dense - packed cellulose) Windows U -Value = .30 I SHGC Value = .25 Skylights none Glass Doors U -Value = .32 I SHGC Value = .25 Solid boors U -Value = .20 or less Ceilings R52 (14" blown cellulose) Attic Hatch R30 (6" XPS) Blower Door Test 5 Air Changes per Hour at 50 pascals (2127 CFM)* Thermal Enclosure Checklist Section 3 & 5 requirements verified by a HERS Rater The 2009 IECC requires a blower door test result of 7 ACHSO or lower. The number listed here requires significant irmoroverrrents in air sealing beyond the base energy code. Mechanical Equipment Heating Equipment Natural Gas Furnace, 95 % AFUE with ECM motor Cooling Equipment none Water Heating Equipment Natural Gas Instantaneous, .82 Energy Factor location: ducts located in the conditioned basement Ductwork insulation: none required leakage: 1 CFM per 100 sq ft of conditioned area (16 CFM) ** Exhaust Fan - fan must meet the following criteria: 1) Hard -wired to run continuously OR controlled by a programmable timer Ventilation 2) Rated for continuous operation 3) Sound rating of 1 sone or less 4) Maximum power usage rated at 11.3 watts at 49 CFM _ 5) Capable of exhausting 49 CFM Ilrr..2OlffJ It CC requires, a duct laatrage fast of 8% leakage to the outside or lower. The number listed hero requires significant improvements in duct sealing beyond the base energy code. Lighting & Appliances Lighting 80% of light bulbs are compact fluorescent or LED bulbs Refrigerator Energy Star rated, 555 kWh per year Dishwasher Energy Star rated, Energy Factor = .66 Builder Agreement I understand that to reach the required HERS Index threshold for the Stretch Energy Code I must include all the specifications listed above. I must also meet the performance testing thresholds and the prescriptive Thermal Bypass Checklist. Signature: - Date: bi 1 9 / I Printed Name: , TA.t. 6.4 '0' e/ ) lit Company: QUICK ANALYSIS REPORT • Date: June 19, 2012 Rating No.: 045 -12 Building Name: Melnik Residence Rating Org.: Power House Energy Consulting Owner's Name: Patrick Melnik Phone No.: 413 - 835 -5162 Property: 22 Beaver Brook Rater's Name: (Matt Turcotte Address: Northampton, MA01053 Rater's No.: 1497133 Builder's Name: Ed Jazab Carpentry Weather Site: Northampton, MA Rating Type: Based On Plans File Name: 045 -12 22 Beaver Brook upgrades.blg Rating Date: 6/10/12 Codes Programs IECC 2009 Performance: Fails EPA ENERGY STAR 2.0 Fails IECC 2006 Performance: Passes EPA ENERGY STAR 2.5 Passes IECC 2004 Performance: Passes EPA ENERGY STAR 3.0 Fails IECC 2003 Performance: Passes Tax Credit Fails IECC 2001 Performance: Passes HERS Index 63 IECC 2000 Performance: Passes IECC 1998 Performance: Passes ECC of NY Performance: Passes ECC of NV Performance: Fails MEC 1995 Performance: Passes MEC 1993 Performance: Passes MEC 1992 Performance: Passes ASHRAE 90.2 Performance: Passes REM /Rate - Residential Energy Analysis and Rating Software vi 2.96 This information does not constitute any warranty of energy cost or savings. iJ 1985 -2011 Architectural Energy Corporation, Boulder, Colorado. MUNICIPAL SEWER/ AVAILABILITY APPLICATION Northampton Streets Department 125 Locust Street Northampton, MA 01060 587 -1570 A Department of Public Works Trench Permit and Sewer Entry Permit shall be required prior to any construction or connection activity associated with this application. Location: 28 Evergreen Road, Unit #22 I as Inquiry Made By: Pat Melnik 584 -6750 Date of Inquiry: 4/4/12 Reason for Connect into City Sewer Request: Municipal Sewer Main in Front of Location: Yes No Municipal Storm Drain Available: 5'/2 deep Yes No Size of Sewer Main: 8 Material: C P, V Age: Depth of Sewer Main: Size of Service Connection: Type of Service Connection: Tie -in to Sanitary Main Tie -in to Sanitary Stub Comments: /J2 1 U'Alt -, Note: If this availibilitv is for new construction, this form must be hand delivered to Building Inspector. A corresponding "sewer entrance fee" shall be paid prior to making any connection to the municipal sewer system. Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department specifications. John all C, IC Sewer Department cc: Ned Huntley, Director DPW Louis Hasbrouck, Building Commissioner MUNICIPAL WATER AVAILABILITY APPLICATION Northampton Water Department 237 Prospect St. Northampton, MA 01060 587 -1097 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: 28 Evergreen Road, Unit # 22 LOT o.d Inquiry Made By: Pat Melnik 584 -6750 Date of Inquiry: 4/4/12 Number of Type of Single Family Apart. Type of Private X Units: 1 Unit(s): Multi- family wnership: Condo Rental (Annlicant to fill out the above) Municipal Water Main in Existing service to Front of Location? Yes: X No: site? Yes: No X Size of Water Main: 8" Material: Ductile Iron Age: 2006 Approximate Static Street Flow Test Conducted: Yes: No: X Pressure: 40 If done attach results Size of Service Connection 1" Suggested Meter Size: 3/4 Comments: The Water Department cannot guarantee adequate water pressure during peak demand times at elevations above 320 feet. • A corresponding water entrance fe- . 11 be paid prior to making any connection to the municipal water • Arrangement of such •i t. ation . all be made with the Northampton Water Department with a minimum of 5 workin,. da s tifi.. '. . • ` All work s all ' nf • North. •to Department specifications. David Sparks, Superintendent of Water Dept. Water Entry $200.00 Meter $150.00 Radio $100.00 cc: Ned Huntley, Director cc: Louis Hasbrouck, Building Commissioner Note: If this availability is for a new construction, it must be hand delivered to the Building Inspector. • ibt \'titer Application Water Alailab €lity.doc v\ • and delivered as provided In this Section. Notices are deemed given when deposited, as described above, with the U.S. mall or in the overnight receptacle. Any such notice, if sent by the Customer to the Seller, shall be addressed as follows: • SIGNATURES CONSTITUTE ACCEPTANCE OF THE TERMS AND CONDITIONS CONTAINED HEREIN. AGREEMENT VALID UPON SIGNATURE OF CHUBB MANAGER. Chubb Fire & Security, LLC Patrick J. Melnik, Sr. Proposed By: Accepted By: ' 4t01/0 ap'LL2a i 0 - Steve Jaquith Date 6/5/12 y Account Specialist Accepted By: Date Manager, Chubb Fire & Security, LLC • • • Page 5 of 5 • 9. FORCE MAJEURE: Seller shall not be liable for any failure to perform or delays in installing or repairing equipment or systems, or for any interruption of any service to be performed hereunder, or in the performance of an obligation hereunder as a result of an event beyond its reasonable control, including, but not limited to, strikes, industrial disputes, fire, flood, acts of God, war, vandalism, riot, national emergency, acts of terrorism, embargoes or restraints, supplier default, supplier default, extreme weather or traffic conditions, order or other act of any governmental agency, and shall not be required to supply any service to the Customer while interruption of such service due to any such cause shall continue. Service charges shall cease until service is resumed. 10. WAIVER OF CONSEQUENTIAL DAMAGES: NOTWITHSTANDING ANYTHING ELSE IN THIS AGREEMENT, NEITHER PARTY SHALL BE LIABLE FOR ANY INDIRECT, LIQUIDATED, CONSEQUENTIAL, SPECIAL OR ECONOMIC LOSS, COST LIABILITY, DAMAGE OR EXPENSES HOWSOEVER ARISING, WHETHER OR NOT FORESEEABLE AND WHETHER OR NOT DUE TO NEGLIGENCE OF EITHER PARTY IN PART OR IN WHOLE. 11. LIMITATION OF LIABILITY: Notwithstanding anything to the contrary herein and to the extent permitted by law, the aggregate liability of Seller to the Customer, whether in contract, tort (including negligence), or otherwise will be limited to one (1) times the contract value, provided however the foregoing does not limit the liability of Seller for any injury to, or death of a person, caused by the gross negligence of Seller. 12. ENVIRONMENTAL: Customer agrees and acknowledges that Customer shall be solely responsible for all costs, expenses, damages, fines, penalties, claims, and liabilities associated with or incurred in connection with hazardous materials or substances upon, beneath, about, or inside Customer's equipment or property, and Customer shall be solely responsible for reporting the presence of said hazardous materials or substances to the proper governmental authorities. Customer further agrees and acknowledges that title to, ownership of, and legal responsibility and liability for any and all such hazardous materials and substances at all times shall remain with Customer and that Customer shall be solely responsible for the removal, handling, and disposal of all hazardous materials in accordance with all applicable governmental regulations. 13. EXPORT COMPLIANCE: Customer hereby represents and warrants that it will comply with the requirements of all applicable export laws and regulations, including but not limited to the U.S. Export Administration Regulations, in the performance of this Agreement and the treatment of Confidential Information herein. It is understood that countries outside the US may restrict the import or use of strong encryption products and may restrict exports, and Customer agrees that Customer shall be solely responsible for compliance with any such import or use restriction. Customer agrees to indemnify and hold harmless Seller from any costs, penalties, or other losses caused by, or related to, any violation or breach of the representations and warranties in this provision. This provision shall survive any termination or expiration of this Agreement. 14. FEDERAL ACQUISITION REGULATIONS: The components, equipment and services proposed by Seller are commercial items as defined by the Federal Acquisition Regulations ( "FAR ") and the prices in any resulting contract and in any change proposal are based on Seller's standard commercial accounting policies and practices which do not consider any special requirements of U.S. Government cost principles and do not meet the requirements of Part 31 of the FAR or any similar procurement regulations. Seller agrees only to perform a contract for the sale of a commercial item on a fixed -price basis. In addition, Seller will neither agree to submit or certify to any cost or pricing data nor to any requirements to establish price reasonableness under FAR Part 15 or such similar regulations. In stating its position, Seller refers to FAR Part 12 - "Acquisition of Commercial Items." 15. GENERAL: (a) This Agreement, and the Scope of Work, constitutes the entire Agreement between Customer and Seller and supersedes all prior written and oral agreements in relation to the work contemplated under this Agreement. (b) No amendments, modifications, or supplements to this Agreement shall be binding unless in writing and signed by both parties. It is agreed that for any alteration to or deviation from this Agreement involving extra work, the cost of material or labor will become an extra charge (fixed -price amount to be negotiated or on a time - and - material basis at Seller's prevailing rates then in effect) over the sum stated in this Agreement. (c) Any rejection of goods for being nonconforming under the requirements of this contract must be made by the Customer by sending written notification to Seller of the rejection within fifteen (15) days after their delivery. Such notification shall state the basis of the alleged nonconformity of the goods and the description of that portion of the shipment being rejected. (d) This Agreement shall not be in effect or binding upon Seller until signed by its duly authorized representative. (e) Customer may not assign its rights or delegate its duties hereunder without the specific, written consent of Seller. 16. GOVERNING LAW: This Agreement shall be interpreted in and governed by the laws of the State in which the work is to be performed including all matters of construction, validity, performance and enforcement. Attorneys' fees and other legal costs may be assessed. This Agreement may be executed in multiple counterparts, each of which shall be deemed an original and of equal force and effect. 17. COSTS AND ATTORNEYS' FEES: In the event that it shall become necessary for Seller to employ a collection agency or attorney to collect unpaid charges or any other sums Customer may owe hereunder, Customer shall be liable to Seller for Seller's reasonable and necessary costs of collection and attorneys' fees incurred in such collection activities. In the event of any other legal proceeding related to this Agreement, the prevailing party in such proceeding shall be entitled to recover its costs and reasonable attorneys' fees from the other party. 18. SEVERABILITY: If any term, covenant, condition or provision of this Agreement, or the application thereof to any circumstance, shall, at any time or to any extent, be determined by a court of competent jurisdiction or an arbitrator to be invalid or unenforceable, the remainder of this Agreement, or the application thereof to circumstances other than those as to which it is held invalid or unenforceable, shall not be affected thereby and each term, condition or provision of this Agreement shall be valid and enforceable to the fullest extent permitted by law. 19. SUBCONTRACTING: Seller shall have the right to subcontract, in whole or in part, any installations and /or services, including but not limited to, monitoring services and /or limited warranty /extended limited warranty services which Seller may perform. Customer acknowledges that this contract and particularly those paragraphs relating to Seller's limited liability, disclaimer of warranties, and third party indemnification, inure to the benefit of, and are applicable to, any assignees and /or subcontractors with the same force and effect as they bind customer to Seller, 20. NOTICES: All notices under this Agreement shall be in writing, signed, dated and sent by overnight courier or registered or certified U.S. mail, postage prepaid, return receipt requested, to the parties at the addresses shown below. All changes of address must be in writing Page 4 of 5 3. WORK HOURS: Seller will perform all work during normal business hours: Monday through Friday, 7:00 a.m. to 3:30 p.m. Any requests for work to be performed outside normal business hours will be billed at Seller premium rates in effect at the time the work is performed. 4. INSTALLATION /SITE CONDITIONS: Seller will arrange for installation of the equipment in accordance with specifications, drawings and instructions provided by Customer, which specifications and drawings are considered a part of this Agreement. Customer shall provide Seller a safe working environment and unencumbered access to all areas where work is to be performed. Customer acknowledges that Seller's service personnel have been instructed not to perform any work in hazardous locations until working conditions have been made safe, as determined in the service personnel's sole discretion, and it is the responsibility of the Customer to take any measures necessary to eliminate such hazards before the work may proceed. Customer shall provide reasonably adequate lighting, heating, ventilation and other working conditions to permit safe and proper installation. Suitable foundations, wall openings, curbing holes, pits, tunnels, culvert piping, grouting, surrounding masonry and concrete, canopies and architectural enclosures, and sun screens shall be constructed by others at Customer's cost. Customer shall also provide at its own expense the power and lighting that is required for proper operation of the equipment. If, through no fault of Seller, Seller cannot proceed with the work within a reasonable time after delivery of the equipment and/or Seller's arrival at the work site, Customer shall pay Sellers actual expenses, including, but not limited to, additional service fees and any storage fees incurred by Seller in waiting to proceed or in returning to Customer's premises to perform the work. Customer shall notify Seller of any cancellations forty -eight (48) hours in advance of any scheduled service call. Failure to so notify will result in an additional service fee charged to Customer. Customer shall secure and pay for any required building permits and govemmental fees, licenses, and inspection necessary for the proper execution and completion of the installation of the equipment which are legally required at the time that the installation is done. Customer shall give all notices and comply with all laws, ordinances, rules, regulations and lawful orders of any public authority bearing on the performance of the work. In the event that Seller is required, in connection with the installation of the equipment, to do additional work either because Customer did not prepare the job site, or because the drawings, wiring, or other work done by Customer or for Customer by others, was not properly represented in the drawing supplied to Seller, Seller shall have the option of doing the additional work required to complete the job, and will charge Customer at Seller's current prevailing rates for such work, or, of abandoning the installation and being paid in full by Customer upon demand therefore. Any additional amounts so charged shall be due within ten (10) days of receipt of invoice by Customer. Customer represents to Seller that it has an interest in the real estate on which the equipment is to be installed and that has the authority to and hereby authorizes Seller to do the work as provided in this Agreement. Further, Customer warrants that the job site at which the installation work to be done hereunder, complies with all applicable safety and work rules, OSHA regulations, and other governmental and contractual requirements as to working conditions. 5. TIME AND MATERIALS SERVICE WORK: In the event that Seller is asked by Customer to perform service work on a time and materials basis during the term of this Agreement, and such work is outside the scope of work contemplated herein, the Customer understands and agrees that any such time and materials work will be performed by Seller pursuant to the terms and conditions contained herein. 6. WARRANTIES: INSPECTION WARRANTY - Seller makes no warranty, express or implied, in connection with any inspections services provided hereunder. SERVICES WARRANTY - For all other services, including those provided on a time and materials basis, and excluding inspection services, Seller warrants that the services provided hereunder will be performed in accordance with generally accepted industry standards and practices. In the event that any services fail to comply with the foregoing standard within one (1) year from the date services are completed, Seller will re- perform the non - complying services at no additional charge. PRODUCTS/ REPLACEMENT PARTS WARRANTY - Any equipment or replacement parts provided by the Seller will be warranted for a period of one (1) year from the date the equipment or replacement parts are installed by Seller. In no event shall Seller have any obligation to make repairs, replacements or corrections required, in whole or in part, as the result of (i) normal wear and tear, (ii) accident, disaster or other event beyond the reasonable control or fault of Seller, (iii) misuse, fault or negligence of or by Customer, (iv) use of the equipment or replacement parts in a manner for which they were not designed, (v) causes external to the equipment or replacement parts such as, but not limited to, water damage, power failure or electrical power surges or (vi) use of the equipment or replacement parts supplied by the Seller in combination with equipment or software not supplied by the Seller. Any installation, maintenance, repair, service, relocation or alteration to or of, or other tampering with the equipment or replacement parts performed by any person or entity other than Seller without Seller's prior written approval, or any use of replacement parts not supplied by Seller, shall immediately void and cancel all warranties with respect to the affected products. THE FOREGOING WARRANTIES ARE THE SOLE AND EXCLUSIVE WARRANTIES GIVEN BY SELLER IN CONNECTION WITH THE SERVICES PERFORMED AND PRODUCTS PROVIDED HEREUNDER, AND ARE IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND, WHETHER EXPRESS OR IMPLIED, ORAL OR WRITTEN, WHICH ARE HEREBY DISCLAIMED AND EXCLUDED BY SELLER, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE. 7. INDEMNIFICATION: Seller agrees to indemnify the Customer for losses due to bodily injury, or property damage to the extent caused by Seller's negligent acts or omissions, or the negligent acts or omissions of its employees, agents and subcontractors during the performance of this contract, but not to the extent caused by others. 8. INSURANCE: Seller agrees to maintain the following insurance during the term of the Agreement with limits not exceeding the staled amounts: (a) Comprehensive General Liability insurance covering bodily injury and property damage with a limit of $1,000,000 per occurrence and $2,000,000 general aggregate, (b) Statutory workers' compensation and employer's liability insurance for a limit of $1,000,000 per occurrence, (c) Automobile liability covering bodily injury and property damage with a combined single limit of $1,000,000 per occurrence and (d) Excess /Umbrella Liability Insurance with a limit of $1,000,000 per occurrence and $2,000,000 general aggregate. If Seller is performing services on Customer's site, Customer will be named as additional insured under the Commercial General Liability policy only with respect to liability arising out of bodily injury or property damage but only to the extent resulting from the negligent acts or omissions of Seller or its willful misconduct arising out of the ongoing performance of its obligations under the contract. Seller does not otherwise name parties as additional insured or agree to waive its rights to subrogation. Seller does not provide copies of its policies, certified or otherwise nor does it provide endorsements. Page 3 of 5 B. INCLUSIONS: 1. Permit fees 2. Comprehensive general liability insurance 3. Shop drawings 4. Water flow'& tamper switches (wiring by others) 5. Hydraulic calculations 6. Approvals from the authority having jurisdiction. C. Exclusions: 1. Insulation 2. Utility or alarm company fees 3. Fire watch 4. Control wiring 5. Electrical wiring or alarm connections to a central monitoring station 6. Painting 7. Cutting or patching 8. Hose racks/ cabinets 9. Fire extinguishers 10. Sprinkler protection in any other area 11. Premium portion of overtime labor 12. Bond premium (available upon request) 13. Fireproofing/ firestopping 14. Excavation, backfill, dewatering or shoring 15. Thrust blocks 16. Equipment handling of underground pipe and fittings 17. Concrete work 18. Testing and flushing of underground piping installed by others 19. Fire pump & tanks 20. Exterior piping 21. Cutting of ceilings to accommodate sprinklers 22. Seismic bracing 23. Structural load bearing analysis Chubb Fire & Security, LLC. operates an open shop. We have figured this project at our usual rates for mechanics and will perform the work with our own people. This quotation is contingent upon a satisfactory credit check of the General Contractor, Owner, and /or the project funding. Due to the uncertainty of material prices we will be unable to honor this quotation after ten (10) days. SALES AND SERVICE AGREEMENT GENERAL TERMS AND CONDITIONS THE FOLLOWING TERMS AND CONDITIONS WILL GOVERN ALL TRANSACTIONS BETWEEN CUSTOMER AND SELLER FOR THE GOODS AND SERVICES THAT ARE THE SUBJECT OF THIS AGREEMENT. THESE TERMS AND CONDITIONS ARE INCORPORATED BY REFERENCE INTO ANY PURCHASE ORDER ISSUED BY CUSTOMER AS IF EXPRESSLY SET FORTH THEREIN. ANY ADDITIONAL OR DIFFERENT TERMS OR CONDITIONS CONTAINED IN CUSTOMER'S PURCHASE ORDER OR IN ANY OTHER DOCUMENT SHALL BE DEEMED OBJECTED TO BY Seller AND SHALL BE OF NO FORCE OR EFFECT. THE PARTIES EXPRESSLY AGREE THAT MONITORING SERVICES ARE SPECIFICALLY EXCLUDED FROM THE SCOPE OF THIS AGREEMENT. 1. PAYMENT: The Customer will promptly pay invoices within thirty (30) days of invoice date. Should a payment become thirty (30) days or more delinquent, Seller may stop all work under this Agreement without notice and /or cancel this Agreement, and the entire Agreement amount shall become due and payable immediately upon demand. A finance charge will be added to past due accounts at the rate of one and one -half percent (1.5 %) per month, or at the highest legal rate, whichever is less. Any standard goods that are either received at the Seller warehouse, or delivered to the Customer site, that are later canceled or returned by Customer are subject to a fifteen percent (15 %) restocking fee. Any custom orders are subject to a one hundred percent (100 %) restocking fee. 2. TAXES: The Customer shall be responsible for all taxes applicable to the work and/or materials hereunder. Page 2 of 5 I Chubb Fire & Security LLC. 32 Char Drive Westfield, MA 01085 Tel 413- 568 -4709 Fax 413 - 562 -7298 www.chubbfs.com MA SC #5864, CT FRP #0040818 -F1 Chubb RI FPM #374, MA FA #607C, RI FA #9065 A UTC Fire & Security Company CT ELC#105916-L5 June 5, 2012 Melnik Law Offices 110 King St Northampton, MA 01060 Attn: Patrick Melnik Re: Beaver Brook Estates Site #22 Leeds, MA Subject: Automatic Fire Sprinkler Quotation Dear Patrick, Chubb, a UTC Fire & Security Company offers a full line of fire protection services. Installation and repairs of fire sprinkler & fire alarm systems, tenant fit -outs, design build projects, NFPA inspections and 24 -hour emergency service are all provided by Chubb. These services are available throughout the Southern New England region. We are pleased to offer our quotation in the amount of $6,500.00 (Six Thousand Five Hundred Dollars) to install the automatic fire sprinkler system at the above referenced project. A. Our quotation is based on the following scope of work: 1. Plans & Spec's as per Nelson Design Group LLC.. Dated 1/1/98 2. Adequate water supply 3. Residential sprinklers installed throughout. 5. Plans to be reviewed by local authority having jurisdiction. 6. All work and material will be in accordance with NFPA 13D, 2002 edition 7. Installing white concealed sprinklers on the first floor and brass pendent sprinkler on exposed steel pipe in the basement. 8. Adequate heat in all areas containing sprinkler pipe. 9. The piping for the first floor will be installed above the bottom cord of the attic trusses. Your insulation contractor will be responsible to cover the piping to allow the heat from below to radiate up and protect the piping from freezing. Page 1 of 5 51' -6" GLASS BLOCKS • I 0 8» BOXED COLUMNS D ,,.,.,,,,,,. ,W,,,,,,,,,,,,,u WHP GRILLING COVERED PORCH TUB PORCH I3'-2" X 9'-2° 10'-5" X 9' -2 1 DINING M.BATH ROOM 15' s° x lo' a° "I __ II' -0" X 9' 4" (� � � A q BREAKFAST GAS \��� - ROOM FIREPLAC 1 10' -0" X 11'-0" ' , OPEN BAR MASTER COMPUTER (GREAT ROOM 1 SUITE CENTER .mm.■ ° 9' BOXED CEILING KITCHEN 9' BOXED CEILING ® PG 15' -2" X 10' -8" I 13' -6" X 19' -8" I 15' -8" X 12' -0" ® DW, -- • BATH PAN ° 1 L5`✓ _= J D 1 d' S LAU. e . 4 r -- 1_ 6'-4"X ®f I m ■ ;'\ 5 ' -6 " V l �I N- �,� — wH D FOYER BEDROOM 2 ° .. 6' - 6• x T 10' -2" X l0' -8" BEDROOM 3 10' -0" x 10' -8" +---, o a GARAGE 20' -10" X 20' -0" PORCH 9' CEILING 16' -5" X 5' -0" I DO DO 1998 NELSON DESIGN GROUP, LLCI it 1 FoYktt- Main Floor } 2 , K NDG113 -1 -1 Chestnut Lane House Plan - 6100 / Page 1 of 1 4 . READY -MADE .HOUSE PLANS SHIPPED FAST AND FREE 16 Call (866) 214 -2242 for questions or to order I Email us of IP f 1 House Plan Details dr Home I Find A Plan • I About Plans T I Builders T I Product Ideas +, I Our Design ON Plan 2 FOLLOW ME CI 1 <. W 1. r e�ri F g 4:P; i 5 / .' , ` � ) I , 1 ._ _� Stori . I b 4 Tota ' r 'y t,, '' `, N �,' � �, : First , to Bedr t Full I ' . r W dt v ' 1 ( Gara �, � . t � Four .. M 4 . _ t`1ic�tr,st “ �.' ° L � � -1 - 1 --- ll. - Base �.� � e� is di 4 �, sx sr s R !aW �s*� + a ti r' # r w i ,„ ., v p N i 9 s y , i ... � °tl �,� t 9, t � « a, 5� 14 A a �� ���� : � � . , { p ��' ' ;6i.,... , g���tt #`��;� ,,,,,,6ya „.ttiii* ti,A,.,d,ite,.ea' aid tivt3 4 har4 + WiFi16,���1( �i '', '' Front Rendering Won IIV Click on image above to enlarg See All Plans By This Designer > Free Cost Estimator > Modify Plan Save This Plan Newsletter Sign -up Need to make changes? Create an online portfolio of Each week receive our Request a free online quote. favorite house plans. free e- newsletters. First Floor: _1-- / c \11 \) \... / i ii ? */// Moc http:// www. thehousedesigners .com/plan/chestnut- lane -6100/ 3/22/2012 POSITIONING AND SITE P S EE S . H EE \ NorxnWJ n }oz_ i t RNaR P " E S T m 1 � ZI J ' PROPOSED n BEAVER BROOK D © 0 oao' BOK 1 109. f o I 1 OF u R se O MENY LSO (UNITS CONDOMINIUM �) 0 t 50 - �-. —. —. ii: - s u THE HEIRS OF N - P, NBTOB'28 E I BOOK 2546 na Fm� o_ �s \ > N Bi }l J3 Ems' f1t - s . s� nry;^ _ 2249' SE GROBaiE /93P017.3 tt ^ — 0 1.42.5, 1.42.5, ' - wM 1 })9 ' T- '' ]151 1O0 9>,O 2 NB1'Sl }J E� t EMNN LAO R S S m�z - r -t-" '''7.32--± t-" t1B♦ v 3 SBf'3' 33W ° °` PATRCE3 M oi< "' o EAVCR BR m ` 2A O u TE E W'dmme NOMINEE TRUST ■ - 5 IZ" - �- , to v, ° W B (SEE 6 I u 8Y © Wy °gx AREA - W, '9 z oo o a.3, - -= M pg 46 s2 ' EXCLUSIVE UNIT ti ,v sfirl6 ze _ _ ,33 im C � $ r 30,4 S. _1 - 2?... _, - 131.42 ,S (207AL 3 970 i ` 919 '?- ��58Z16]BW L ES EASE EN `� _ t6 - // N — 584's3'J6W EXCLUSIVE IT I I'/ _ SB66 TBW _ _ 552 V VVV 9 fi I - - X 58 t 'SJ'!JW 10,953 S E. _ o N81'ST 3JT� 2r.0'YI '240, 4 o ® xn Z 9 - _i § 1 Tr u o JOHN E. KIB5K1 F CLUSI NI O vE UT 1 n& m BOOK 5862. PAGE 3 u 467 ., 6 S. BOOK 5958, PAGE 13 F4 -1 BOOK 6078 PAGE 11 9 U 2543 � 9� EXCLU LWR YANKEE CONDOMINIUM EE HP0 o 116. t 2 ' 2 BKF£ H OOK 3023, L BOOK 5860 CE 160 T PUN BOOK 54, PAGE ; —33,w 14 , 5'Y — G� 92 f •' BOOK 3066, PAGE 7 PUN BOOK 32 PAGE J8 �SBI'3J ry8t'3]'3} EEO SEE ALSO PL. BOOK . PAGE 80 Plan BOOK 197, PAGE 27 ]002 "�_ - m Exctu5lOvE UN o� L m A�� m EA UNIT m 017' u 11.6 t vl' 77 S.E.t 3 I . 252'2 21 BY t f ,42. - O . _ R i.m 89.53' 2J2.N2_ 2]8.42' (TOTAL) ti / 117 s8' � I LINE 8t 3]'3!'E -' t1 O O 1- CII INIUM BOUNON Z 1 W, m \.. NOTES: n - 2B oEROREEN ROAD 1 FOR REFERENCE PAGE TO ENCLOSED PERIMETERS SEE ROOK 5493. PAGE 23, BOOK 5869, AGE 6 BO F (UNOOMINSU P K 5917, 06, BOOK 9496. PAGE 133, P BOOK 32. PAGE o, PUN BD, PAGE 80, PLAN BOOK 115, PAGE 11. Z -------------7--- -------------7--- PUN BOOK 186, PAGE IBS. BOOK 33, PAGE 37, P BOOK R E 27, P BOOK 188, P O E X C LUSI V E UN? UN BOOK 106, PAGE I. uN BO 1,1, PAGE 47 AND B BOOK 2 PAGE E O \ 5 - � �Px SEE ALSO. -N wG SURVEYS. PL VE YS. M LAI U BROOK , 2 0 N PT0.v. 0 6. m O 18, 93�5 M1 (TO B E D RECORDED NOT EOU E HAP RVE 0 ' J'4 0W ( U STS S OwN H E HEREON RE C ARE SUBJECT REGISTRY OF ENT TO - EXCL COMMON AREA EN D IN BNE UNITS ENGLAND /ECi TO AN EASEMENT NBY411.E -' VERIZON NN./ C.. CORDED IN BOOK 684, PAGE 257 O 80 N ,03 Y . 11 9 S. E A = 2. E CLU U IT AREAS f E APPROVED U DER A CLUSTER DEVELOPMENT j6.90' 2J 0'Y 14 F.t RE PLAN fOF ZONING SPFCML UN APPROVAL AI FlNG. SEE PL NS u WEED MARCH ,2, 2008 G REPARED BY THIS OFFICE. r ALSO SEE PLA ECORDED A.. DECISION, HEARING N0. N- 1008 -038, DATED PROPOSED W BD. 9482, PAGE 3 o FAVEMENT SRVEY CONDUCTED Y VANESSE HANGEN BRuSST DE OF HORIZON AL CONTROL WAS ESTABUSHFD BY A GLOB SITIONS SYSTEM (CPS) - CXCLUS m 1. NUN. INC. PORT !ROm HERITAGE SURVEYS. C ON FEBRUARY 4. D I 2.57 E 5.71, �1 I T _, BB.BS 200.85 ROAD -- GEORGE KGHO, tr EBRA ORGE o- - - �_J — EVERGREEN �- n BooK D Jfisz WcE RA 3I5 HORIZONTAL SCALE: 1' = 40' m� ' N E" T H` Z P C :LAN — SHEET 2 OF 4 O Z y BOK 35 PAGE 52 BOOK 08529, PAGE 24 rn C PLAN SHOWING PROPOSED EXCLUSIVE UNITS —1 So BEAVER BROOK ESTATES Ro.W NORTHAMPTON, MASSACHUSETTS OWNER /DEVELOPER: REGISTRY OF DEEDS PATRICK J. MELNIK. TRUSTEE PRELIMINARY HAMPSHIRE COUNTY THE BEAVER BROOK NOMINEE TRUST LEGEND 110 KING ST. THIS PLAN SHOWS THE PROPERTY LINES THAT ARE THE LINES OF NORTHAMPTON, MA 01060 STONEBOUNL FOUND • EXISTING OWNERSHIP, AND THE LINES OF STREETS AND WAYS SHOWN TEL. (413) 584 -5750 DATE: JUNE 5, 2009 PIPE 0 A THOSE OF PUBLIC OR PRIVATE STREETS OR WAYS ALREADY IRON .R FOUND ESTABLISHED, AND NO NEW LINES FOR DIVISION OF EXISTING OWNERSHIP IRON PIPE T SET • OR FOR NEW WAYS ARE SHOWN. FURTHERMORE. THIS SURVEY AND HERITAGE SURVEYS, INC. STONE WALL PLAN WERE PREPARED IN ACCORDANCE WITH THE RULES AND REGULATIONS EMBED WIRE FENCE — — — — — — OF THE REGISTERS OF DEEDS, AND THE PROCEDURAL AND TECHNICAL PROFESSIONAL SURVEYORS AND ENGINEERS EXCLUSNE UNIT LINE - — — — - STANDARDS FOR THE PRACTICE OF LAND SURVEYING IN THE COMMONWEALTH 242 COLLEGE HIGHWAY M CLARK STREET FM EOF EXISTNG EASEMENT - — — — — - OF MASSACHUSETTS. POST OFFICE BOX 1 BASELINE - - - - - -- MM' SOUTNAMPTON, MASSACHUSETTS 01073 -0001 PERMANENT CONSERVa RESTRICTION (4t 3) 527 - 3600 DATE REGISTERED LAND SURVEYOR ,,,,3 , 3923- 980831 kn., 39234005 T • 3923- 090605 , .,iwoigiigwomimm--------- \ . : SHEE 3 . BEAVER BROOK ;ED EVERGREEN ROAD \. E 2 CONDOMINIUM . (UNITS 6-29) 4.0 f t �. 142.5' p{ MAPLE 2 N81 , 3 7 ' 3 3 E 1 �" o C) . ---- 118.4 N .d , N- .. j 1 �± In r 24.0 ., 1 t 8� U) 24. e„ cz o P o o o o� N k ■ 135 - � � . -�- 581 ` = � ..d- 9 �, t 3 ° = — , ,I 24.0' 24.0 � �o o� o �-)r- M IT i 25. ,o1., - 7 L 2 3 4 :: • ; � EXCLUSIVE UNIT 4, . AREA = Co '•'' 141. ---; ,w .0 _ �( '° \ ', r 1 6,020 .5.1 N81' t � r -- s 5 8 , 29.4' ± The Commonwealth of Massachusetts Pr Form _ Department of Industrial Accidents ti == Office of Investigations ei 9 1 Congress Street, Suite 100 T ,r.� r Boston, MA 02114 -2017 www.mass.gov /dia Workers' Compensation Insurance Affidavit: Builders/ Contractors /Electricians /Plumbers Applicant Information Please Print Legibly Name ( Business /Organizati on/Individual): Edward Jazab Address:9 Shepherd's Hollow City /State /Zip:Leeds Ma. 01053 Phone #:413- 222 -4910 Are you an employer? Check the appropriate box: Type of project (required): 1. El I am a employer with 4. n I am a general contractor and I employees (full and /or part- time).* have hired the sub - contractors 6. New construction 2. 0 I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub - contractors have 8. ❑ Demolition working ca employees and have workers' g for me in any capacity. y 9. ❑ Building addition [No workers' comp. insurance comp. insurance.t required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3. ❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, § 1(4), and we have no employees. [No workers' 13. ❑ Other comp. insurance required.] *Any applicant that checks box #1 must also fill out the section below showing their workers' compensation policy information. I Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. Contractors that check this box must attached an additional sheet showing the name of the sub - contractors and state whether or not those entities have employees. If the sub - contractors have employees, they must provide their workers' comp. policy number. I am an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy # or Self -ins. Lic. #: Expiration Date: Job Site Address: City /State /Zip: Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and /or one -year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. Signature: Date: /6 Phone #:413- 222 -4910 Official use only. Do not write in this area, to be completed by city or town official City or Town: Permit/License # Issuing Authority (circle one): 1. Board of Health 2. Building Department 3. City /Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone #: SECTION 8 - CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable Name of License Holder : fJ W A A 14,O Cf j ° 05604.9 License Number 9 S . t I -d s N621o.J 1 taf 0)0T-.? c1 2 Address Expiration hate Si `-�'\ Telephone c 9. Registered me mprovement Contractor Not Applicable ❑ Company Name Registration Number Address Expiration Date Telephone SECTION 10 WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes 1/1. No ❑ 11. - Home Owner Exemption The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature. • SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) New House 0 Addition ❑ Replacement Windows Alteration(s) ❑ Roofing n Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [O] Decks [i] Siding [O] Other [O] Brief Descri or�.�f'P /sed ^ -�'� Work: ��,,JJ + (,T/(/� Alteration of existing bedroom Yes No Adding new b droom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll - Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family x Two Family Other b. Number of rooms in each family unit: 6 Number of Bathrooms 3 c. Is there a garage attached? yes d. Proposed Square footage of new construction. 1623 Dimensions 52X 31 e. Number of stories? 1 f. Method of heating? gas Fireplaces or Woodstoves none Number of each g. Energy Conservation Compliance. Yes Masscheck Energy Compliance form attached? Yes h. Type of construction Wood frame i. Is construction within 100 ft. of wetlands? Yes X No. Is construction within 100 yr. floodplain Yes A No j. Depth of basement or cellar floor below finished grade , k. Will building conform to the Building and Zoning regulations? X. Yes No . I. Septic Tank City Sewer " \ Private well City water Supply .X SECTION 7a - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Ar/Z ∎ C A M I, E (AA as Owner of the subject property e Q ,, t " D "� A Z, hereby authorize to act on my behal all matters relative to work authorized by this building permit application. ‘ id* id- Signature of Ow Da e I /orte., i K j /an OLM K , as Owner /Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name ‘i a ) ds) ) Signature of 0,f Agent Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size 25 Acres 25 Acres Frontage 250 250 Setbacks Front 0 800 Side L:0 R: L:120 R: Rear 0 200 Building Height 0 20 Bldg. Square Footage % 1550 1% Open Space Footage (Lot area minus bldg & paved 24A 99% parking) # of Parking Spaces 0 2 Fill: (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO 0 DON'T KNOW 0 YES • IF YES, date issued: 04/09/2008 IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW 0 YES C) IF YES: enter Book 9482 Page 3 and /or Document # B. Does the site contain a brook, body of water or wetlands? NO C) DON'T KNOW YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained , Date Issued: C. Do any signs exist on the property? YES 0 NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. Department use only ` ' City of Northampton Status'of Permit: % \) t012 �� Building Department Curb Cuttt riveway Permit 212 Main Street Sewer/Septic Availability . Room 100 Water/Well Av ilability Northampton, MA 01060 Two Sets of Structural Plans phone 413 587 - 1240 Fax 413 587 - 1272 Pot/Site Plans Other Specify APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE INFORMATION 1.1 Property Address: This section to be c mpleted by office ti (N1ue"1 A e f.)cr Map OC Lot Unit Zone Overlay District d B it .eng Re t -r Elm St. District CB District SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: Patrick J. At -lnik, Trustee of the Beaver Brook Nominee Trust 110 King St. Northampton Ma. 01060 Name (Prin , 7 Current Mailing Address: 413- 584 -6750 Telephone Signature n 2.2 Authorized Agent: ri4Q ` i e i s l-J cu 6 v � o�.� A �i4Z/ 6 4141=22,2=P9-1.0 L e,t 2 S .r.4 0 I 0 Name (P Current Mailing Address: 413- 222 -4910 Signature \ Telephone SECTION 3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building 120,000 (a) Building Permit Fee 170000 2, Electrical 15,000 (b) EConstruct stimated Total Cost (6 of 170000 from 3. Plumbing 15,000 Building Permit Fee 4. Mechanical (HVAC) 170000 5. Fire Protection 20,000 6. Total = (1 + 2 + 3+4 + 5) 170,000 Check Number L'9L5 6 ? D A/rp This Section For Official Use Only Building Permit Number: I sssuu ed: Signature: Building Commissioner /Inspector of Buildings Date A Nth 't; File # BP- 2013 -0073 q' v , �T APPLICANT /CONTACT PERSON ED JAZAB N EIS p , ` W RE0J ADDRESS /PHONE 9 SHEPHERDS HOLLOW LEEDS (413) 222 -4910 Q PROPERTY LOCATION 62 CHESTNUT AVE EXT - UNIT 22 - 28 EVERGREEN 6 i-f 04 2 MAP 06 PARCEL 064 000 ZONE C THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Buildin . Permit Filled out 41 , – . Fee Paid 0 '-0 vi - .. — i "" ' • 0 Typeof Construction: CONSTRUCT SFH W /ATT GARAGE /PORCHES New Construction Non Structural interior renovation Addition to Existing J Ac o c lan ry Structure 511 _ ' C Building Plans Included: [� Owner/ Statement or License 050099 0O -f ...oN 3 sets of Plans / Plot Plan THE F OWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON I F ATION PRESENTED: Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND /OR Special Permit With Site Plan 1::: ?' `'' Major Project: Site Plan AND /OR Special Permit With Site Plan : ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* / , t 3 -2.3 ,.- d Received & Recorded at Registry of Deeds Proof Enclosed v A a I- Ohl-- Other Permits Required: rE E bUbt Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health SL(x Ne W Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management e4e. elay _,-,, _...0 IP. .07 7-5)-7,9'-- Signature of B ilding • fficia Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. UNIT 22 - 62 CHESTNUT AVE EXT - 28 EVERGREEN BP- 2013 -0073 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 06 - 064 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: New Single Family House BUILDING PERMIT Permit # BP- 2013 -0073 Project # JS- 2013- 000103 Est. Cost: $170000.00 Fee: $1343.30 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: ED JAZAB 050099 Lot Size(sq. ft.): Owner: Patrick Melnik Zoning: URA Applicant: ED JAZAB AT: UNIT 22 - 62 CHESTNUT AVE EXT - 28 EVERGREEN Applicant Address: Phone: Insurance: 9 SHEPHERDS HOLLOW (413) 222 -4910 0 LEEDSMA01053 ISSUED ON :8/10/2012 0 :00 :00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT SFH W /ATT GARAGE /PORCHES - must be built to 2009 IRC & stretch code POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 8/10/2012 0:00:00 $1343.30 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner