Loading...
17D-064 (3) BEGm Des AO 3 Pro Deck Railing Details View U J U U U U U lJ U U U U U U U U U 8'0 3 IT � r_ 1 ff 2 E Railing Style 3 Warning and Important Instructions: This is not a final design plan or estimate. EDGENET, INC. assumes no responsibility for the correct use or output of this program. All information contained on this page is subject to the terms in the disclaimer located at the end of this document. Advertencia e instrcciones importantes: Esto no es un plan ni una estimacibn final del diserfto. EDGENET, INC. no asume ninguna responsibilidad del use o de la salida correcto de este programa.Toda la informacion contenida en esta pagina esta conforme a los terminos en la negacion, situada en el extremo de este documento. Copyright © 1989-2012 Edgenet, Inc. Page 7 of 18 Doc ID bc7be187- ae64- 43aa- 9dee- 25e0aca45b99 Pro Deck Design 4 ,:: \A - .. Joist Layout View 7„ 14 4 S i-, ----:,,,, , — 4 raz ,�,:. .« ✓,c ,,, :,., lG Zvi,; .a„ °`,I, �",i, .' .. .W , r - , _,�c 1 §:� W A A A A A A A A A A A A A A A O p p p E p p p p E p En p E p p p n 0 O b O O O O O O O O O O O O O nnnnnnnnnnnnnnnn I o O O p. O N otes: O 6 119 a um Le •- ° e All joist and stringer spacing dimensions are measured in OC. Car ,,/-4i Warning and Important Instructions: This is not a final design plan or estimate. EDGENET, INC. assumes no responsibility for the correct use or output of this program. All information contained on this page is subject to the terms in the disclaimer located at the end of this document. Advertencia e instrcciones importantes: Esto no es un plan ni una estimacibn final del diseilo. EDGENET, INC. no asume ninguna responsibilidad del use o de la salida correcto de este programa.Toda la information contenida en esta pagina esta conforme a los terminos en la negacion, situada en el extremo de este documento. Copyright © 1989 -2012 Edgenet, Inc. Page 6 of 18 Doc ID bc7be187- ae64- 43aa- 9dee- 25e0aca45b99 Pry Deck Design \ 9 Post View 6inI 6in 1 6 in '6 in ePoint A — ,O E P Warning and Important Instructions: This is not a final design plan or estimate. EDGENET, INC. assumes no responsibility for the correct use or output of this program. All information contained on this page is subject to the terms in the disclaimer located at the end of this document. Advertencia e instrcciones importantes: Esto no es un plan ni una estimaci0n final del diseflo. EDGENET, INC. no asume ninguna responsibilidad del use o de la salida correcto de este programa.Toda la informacidn contenida en esta pagina esta conforme a los terminos en la negacian, situada en el extrema de este documento. Copyright ©1989 -2012 Edgenet, Inc. Page 5 of 18 Doc ID bc7be187- ae64- 43aa- 9dee- 25e0aca45b99 • DIGO ,0, Pro Deck De PI Plan View Warning and Important Instructions: This is not a final design plan or estimate. EDGENET, INC. assumes no responsibility for the correct use or output of this program. All information contained on this page is subject to the terms in the disclaimer located at the end of this document. Advertencia e instrcciones importantes: Esto no es un plan ni una estimacion final del diseflo. EDGENET, INC. no asume ninguna responsibilidad del use o de la salida correcto de este programa.Toda la information contenida en esta pagina esta conforme a los terminos en la negacion, situada en el extremo de este documento. Copyright © 1989 -2012 Edgenet, Inc. Page 3 of 18 Doc ID bc7be187- ae64- 43aa- 9dee- 25e0aca45b99 BIG Design 40r 3 Pro Deck Dimension View ■ 22 ft I I • N. J Deck 1 I 22 ft Warning and Important Instructions: This is not a final design plan or estimate. EDGENET, INC. assumes no responsibility for the correct use or output of this program. All information contained on this page is subject to the terms in the disclaimer located at the end of this document. Advertencia e instrcciones importantes: Esto no es un plan ni una estimacion final del diseho. EDGENET, INC. no asume ninguna responsibilidad del use o de la salida correcto de este programa.Toda la informacion contenida en esta pagina esta conforme a los terminos en la negacibn, situada en el extremo de este documento. Copyright © 1989-2012 Edgenet, Inc. Page 4 of 18 Doc ID bc7be187- ae64- 43aa- 9dee- 25e0aca45b99 DIGO Pro Dec D „,,,,. ,,,, ri Sr 3D View �3 ,mi 40e' 3 Ge& a/2 mr r° 7 L ova — : - , '' ' if ' i i f .k f / +Y ✓9 R aas( 4 d'N‘-16/ 1 b b. ,.. .. ,,,,,,,,, „..., ,,,, .. ., ,, 4 eJ Qom/ A.5 /i/L 2.. . aa, 47//, .� ���� ,f#.- , -' Warning and Important Instructions: This is not a final design plan or estimate. D ENET, INC. assumes no responsibility for the correct use or output of this program. All in contained on this page is subject to the terms in the disclaimer located at the end of this document. Advertencia e instrcciones importantes: Esto no es un plan ni una estimacibn final del diser�o. EDGENET, INC. no asume ninguna responsibilidad del use o de la Salida correcto de este programa.Toda la informacibn contenida en es p5gina es conforme a los terminos en la negacibn, situada en el extremo de este documento. Copyright ©1989 2012 Edgenet, Inc. Page 2 of 18 Doc ID bc7bel87- ae64- 43aa- 9dee- 25eoaca45b99 29. Vapor retarders. Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer (diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99% of the moisture in a structure. This is evident every time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 30. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 31. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note: ThruLoks are engineered for post attachment supporting a railing. 32. Smoke and CO detectors as required. 780 CMR R314 and R315. 33. Closets beneath stair which have doors must be drywalled with %z ". 780 CMR R302.7 Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. My email address is: cmiller(a northamptonma.gov Thank you for your cooperation on these matters. Chuck Miller City of Northampton Assistant Commissioner and Zoning Enforcement b. All corners must be appropriately attached to the foundation. 14. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basements, 6'4" at beams /ducts. 780 CMR R305.1. MA amended 15. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4 16. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. Order restrictors. 780 CMR R612.2 17. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape. 780 CMR R310 b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft at 1 floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 %" from the top of the threshold and only in- swinging doors. 780 CMR R311.3 18. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ", maximum riser 8 % ", maximum overall variance for the run is 3/8 ", 4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception, 4 3/8" on balustrade, 6" in the triangle. Graspable rail 1 %" minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 19. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36 ", 4" sphere rule. 780 CMR R312.1. 20. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In interior non - bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1 %2 16ga. strap must extend a minimum of 6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom. Notches are different. 21. Dryer duct transition is limited to 8' of aluminum flex and must be exposed. 780 CMR M1502.4.3 22. Dryer duct maximum equivalent length is 25' or per manufacturer's specs. 780 CMR M1502.4.4.1, no screwed connections. 23. Markup air is required for any exhaust hood of 400 CFM or more. 780 CMR M1503.4 24. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5' from the duct outlet for all fireplaces 25. Fire and draft stopping shall be completed before rough inspection. 780 CMR R302. 26. Ignition barriers in place before final. 780 CMR R316. 27. Dwelling /Garage fire separation. An attached garage (within 3' of main structure) is required to have %" drywall on the garage side of the separation wall and if there is a finished space above the garage all walls must have %" drywall and the ceiling 5/8" drywall. 780 CMR R302.6 28. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. Energy information including mechanical equipment posted on the electric panel. d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Building Option Package. City of Northampton Massachusetts $ J` . e - i> DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building \ 5 ,, Northampton, MA 01060 ss'�ry't)i1 INSPECTOR Richard Rivet August 9, 2012 PO Box 208 Chicopee, MA Subject Location: 14 Garfield Street Map Block: 17D -064 Mr. Rivet, Your plans dated 8 -9 -12 have been approved as drawn, as marked up, and per this memo. These items which will need to be accomplished as the project moves forward; 1. Presumptive bearing allowed is 2000 lbs per sqft. 2. Please pay special attention to items 18, 19, and 31. 3. Band Joist /Beam needs to be 2 -2x8s minimum. 4. 1 %Z" bearing required for all joist. Appropriate Simpson fasteners are required with hangers. As of August 4 2011 the 8 Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8 Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I soils (table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. 5. Through wall form ties must be removed from both faces and patched with hydraulic cement. 780 CMR R406.2 of amendments. 6. Foundation anchor bolts must be %z" and be embedded a minimum of 7" into the concrete. 10" bolts! 780 CMR R403.1.6 7. CMU foundations require 3/8" parging before damp proofing. 780 CMR R406.1 see exceptions. 8. Ceiling joist are intended to prevent spread, once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8 -16nd common are required at each connection. 780 CMR R802.3.1. When there is neither of these a structural ridge is required with a load path to the foundation. 9. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1/3 CMR R802.3.1 10. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 11. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and number of jack studs required. 12. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss 13. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. @8/08/2 @12 16:16 978741 @759 STAPLES217 PAGE 02 F R Cedar Falls AAFR Page No. l o PROPOSAL, P.O. Box 208 of Pages M C- UCOPEE, MA 01021 413- 885 -2852 DATE PROPOSAL SUBMITTED TO: (18 /7/12 NAME JOB NAME —_ Karen Padedc Sprei STREET STREET A — - 14 Garfield Street CITY CITY STATE Florence STATE PHONE MA 01062 _ (978) 745 -9l■ 9 daytime or cell (617)-515-9469 We hereby submit specifications and estimate for. Aquire all permits as per the town of Northampton Massachusetts, work direc ly with the building inspector to ensure successful completion of project . Remove and dispose of existing porch stairs and rail sy ;tem of the front porch, temporarily support the existing roof. Excavate to a depth of 4 feet install 10 inch sonnet tubes and mix and poi r 30X) PS 1. Concrete. Install metal flashing to house and install a two by eight pressure treated ledger hoard, and secure with ledger ock:t screws. Install four b.j� ressure treated posts on 10 inch concrete sonnet tubes. Frame a box 22 feet long by 7 feet deep. In tall ;wo by eight floor joi I • ' hes on center. Install five quarter pressure treated decking and screw to floor joists. Install decoratii ; fotr by four load bearin i .. ed columns to support roof load, utilizing two by 12 pressure treated lumber construct a set of stringer t, and install treads and risers as well as a code compliant rail and handrail system. Install pressure treated two by four and tw• r by two pressure treated ballasters to form a rail system as per Massachusetts building code. To the rear of the home remove and dispc ;e of existing porch stairs and construct a set of stairs to meet Massachusetts building code utilizing the above mentioned materials. Re now: and dispose of a layer of shingles on existing porch roof and dispose of Should plywood be necessary which cannot be kilo vn until shingles are removed this shall be an extra charge of $40.00 per sheet installed. Install drip edge 5 inch install 15 pound f :It paper, install a 30 year architectual shingle. All work shall follow Massachusetts building code and be inspected as required and sigr ed off on by building inspector. At time and material contractor shall give a written estimate as to cost of labor and material only to ebuild any facias and sofetts and install gutters if client should request. Jobsite shall be cleaned on a daily basis and all construction re .ated debris shall be removed from property. We hereby propose to furnish labor and materials -complete in accordance wit 1 the above specifications, for the sum of Six thousand Four hundred Dollars ($6.400.00) with payments to be made as follows: $ 2400 upon acceptance of cont upon completion of project $2000 upon demolition sonnet tubes and concrete poured and inspected $2000 upon successful completion of project with sign offs from building dept rtment. $sofetts and facias shall be reconstructed in a time and material manner exams Ple: should material for soffit and facias be $300 client shall be charged only $300 for materials. Should labor be $300 to construct cl ent shall be charged only $300 for labor cost. Any additional work shall have an additional addendum or separate contract and sh ill be agreed to prior to any work being performed. Client shall be provided with a copy of general contractors insurance and has k three day right to recind contract. should client like to repalce decking with composite and a railing systym with composite, labor sht II not be affected , the only charge shall be the difference between the cost of the wood matierial and composite matierial.. Massachusetts HIC 156493 Massachusetts general contractors license 801 0 i. All material is guaranteed to be as specified. All work to he completed in a workmanlike manner accoriing to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders, and will become n ext•a charge over and above the estimate. All agreements contingent upon strikes, accident or delays beyond our control. This proposal subject to acceptance within I( clays and it is void thereafter at the option of the undersigned. Authorized Signature — — — ACCEPTANCE OF PROF DSAL The above; prices, specifications and conditions are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. ACCEPTED: - p P , ( ) �� J Signature .. i,6, 1 = t;.,_4 .-,„,,., -. , -__ :: 1 . L DATE a gr ... _ , .- c) .-..:, Signature City of Northampton . 7 1 Massachusetts , ° °, { t , `S- ^` f , A� DEPARTMENT OF BUILDING INSPECTIONS � V � 212 Main Street • Municipal Building 0 " ` � 4 = Northampton, MA 01060 F S INSPECTOR Louis Hasbrouck Chuck Miller Building Commissioner Assistant Commissioner HOME OWNER EXEMPTION ACKNOWLEDGEMENT The State of Massachusetts allows the homeowner the right under 780CMR 108.3.4 to act as his /her construction supervisor. The state defines "Homeowner" as, " Person(s) who owns a parcel on which he /she resides or intends to be, a one or two family dwelling, attached or detached structures accessory to such use and /or farm structures. A person who constructs more than one home in a two- year period shall not be considered a home owner." The building department for the City of Northampton wants any person(s) who seek to use the home owner exemption, to act as their own construction supervisor, to be aware that by doing so you become responsible for compliance with state building codes and regulations. The inspection process requires that the building department be called to inspect work at various stages, which include foundation /footings (before backfilf, sonotube holes (before pour), a rough building inspection (before work is concealed), insulation inspection (if required) and a final building inspection. The building department requires these inspections before the work is concealed, failure to secure these inspections can result in failure to obtain a certificate of occupancy until the work can be inspected. If the homeowner other trades to perform work ttelectrical,_plumbing& gas) the homeownerwillbe responsible to make sure that the trades hired secure their proper permits in conjunction to the building permit issued, and that they get their required inspections. Failure of the individual trades to secure the permits and inspections as required can DELAY the project until such time as the proper permits and inspections are made I, understand the above. (Home owner /resident's signature requesting exemption) I will call to schedule all required building inspections necessary for the building permit issued to me. Date Address of work location • The Commonwealth of Massachusetts -^-�...--- Department of Industrial Accidents 1- 0 Office of Investigations .- = 600 Washington Street „i" Boston, MA 02111 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders /Contractors/Electricians /Plumbers Applicant Information Please Print Legibly Name (Business /Or. a nization/Individual): ( vct 11%7- .r u C - 1 - 10 - _ Address: ' ,0 ( ,` lb City /State /Zip: C O (le C? (4 Phone #: 7 Are you an employer? Check the appropriate box: Type of project (required): 1. ❑ I am a employer with 4. ❑ I am a general contractor and I 6. New construction employees (full and/or part-time).* have hired the sub - contractors 2. I am a sole proprietor or partner- listed on the attached sheet. 7. 1:11 Remodeling ship and have no employees Thesesub- contractors have g. demolition for me in any capacity. employees and have workers' working Y p tY• 9. ❑ Building addition [No workers' comp. insurance c msurance. required.] 5. a area corporation and its 10.0 Electrical repairs or additions 3. ❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, § 1(4), and we have no employees. [No workers' 13. ❑ Other comp. insurance required.] *Any applicant that checks box #1 must also fill out the section below showing their workers' compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. Contractors that check this box must attached an additional sheet showing the name of the sub - contractors and state whether or not those entities have employees. If the sub - contractors have employees, they must provide their workers' comp. policy number. lam an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy # or Self -ins. Lic. #: Expiration Date: Job Site Address: City /State /Zip: Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one -year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certi de the pains and penaltie (perjury that the information provided above is true and correct. Date: $ 0 /� Signature: Phone #: Official use only. Do not write in this area, to be completed by city or town official City or Town: Permit/License # Issuing Authority (circle one): 1. Be of H ? B Tlnparttnent 3. City/Town Clerk 4_ Electrical Inspector 5. Plumbing Inspector 6. Other • Contact Person: Phone #: SECTION 8 - CONSTRUCTION SERVICES t. 8.1 Licensed Construction Supervisor: Not Applicable ❑ (,) Name of License Holder : e.40 / e License Num C ber Address Expiration / 3 Signal Telephone 9': Registered ,Home_Improvement..Contrae iii , „_c ,,,_„_ �? , -, ,,, , w , Not Applicabl 0 (/� ^ 3 Company Name Registration Number Address Expiration Date Telephone SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M G L c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes ❑ No ❑ „fir, te .= 14- 74. om eM n + xemp tion The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) , g . New House ❑ Addition El Replacement Windows Alteration(s) I I Roofing I Or Doors 0 Accessory Bldg. ❑ Demolition New Signs [D] Decks [p71 Siding [D] Other [D] Brief Description of Proposed y� C "� M� Co D9 e D� iq 4.C1J De '/\ Alteration of existing bedroom Yes ,......---‹ Adding new bedroom Yes - Attached Narrative Renovating unfinished basement Yes /Icro' Plans Attached Roll - Sheet 4 9 j , a .1: , ew. house. andsor;addition to isttnq'housinq, =.complete the.; follo a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each ' g. Energy Conservation Compliance. _ Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a .:OWNERAUTHORIZATION -TO BE COMPLETED 1NHEN OWNERS AGENT OR.`:CONTRACTORAPPL1ES F'OR BUILDING PERMIT I, , as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date I i ek) C. (0 A- RI v c( , as Owner /Authorized Agent ereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed un er the pains and penalties of perjury. n ICG•t -. c�ivC Print ame i Signature of _ _.ner /Agent Date 1 , , ., Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled1W Building Department 1 / , Lot Size Frontage Setbacks Front : = .. , Side L:. - R: L: ' R: . = = ' i I Rear , = Building Height I 1 Bldg. Square Footage Open Space Footage .... % (Lot area minus bldg & paved I parking) # of Parking Spaces Fill: 1; = = (volume & Location) A. Has a Spec Permit/Variance/Finding ever been issued for/on the site? NO DONT KNOW 0 YES 0 IF YES, date issued: IF YES: Was the rmit recorded at the Registry of Deeds? NO DON'T KNOW 0 YES 0 , IF YES: enter Book I , Page 1 and/or Document # ' I ' B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW 0 YES 0 er ---- IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained , Date Issued: C. Do any signs exist on the property? YES 0 NO -C ----- i IF YES, describe size, type and location: i D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO er IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO 0-- ------- IF YES, then a Northampton Storm Water Management Permit from the DPW is required. . , 7, , ,,,' - R EC _... '',1,...' City of Northampton I i tei2 1 , aPECTICo K , NORTHAM ", ^..!, MA 0 • .,.,_,. APPLICATION TO CONSTRU c d7 T -i n g Department AUG •- 9 212 Main Street Room 100 , 3 - 58 7-1240 Fax 413-587-1272 statb$76f-PeR1,t* :',44;',,-ife.'ii:Le pt,g ,*-- -4 , ,..,..„,,,.: ..„,„,,,, 2 ,..4". - - - ''- '- -' •"` , ""g 4 orthampton MA 01060 .. - ' fbilitii AALater,WellAval, ',./Kgie4lig0". .. 'ad rir la rw0,/S &ISA) 1 r t 1:34-,1?-177,-ii r S ' I:e'; ‘ ;":r------i ' a ' --!.1. 7 „ ; ,„ _ ,- , , ; ,,,,,, k7_ ,t,„ ? , .: , „,t ,„; ‘ , ,,,I , Il f i . f, - , ,, if: i .::, , -. 1 , , 4 ,1 ,. , 1""r „, _.z,, ,,z 7 ,:„ ,„; : ", , , : : :1 ,,,,, ,, ,"` „ . ! '-' r 0thpySpeCifY AL TER, REPAIR, RENOVATE OR D R 14' l SECTION 1 - SITE INFORMATION This section tp be completed bY offi : ' , : ',.:' --, - ..-' !t-,. ',1z ,..--,:.;,,,...;.,,,,,,,,, ,,,,,,...7g,,.,-.1-,-,, ,,,,f-,4=,,,,',,N' th"-,72:,', ,-"." "m; , : - .:44904 . "., , ZZ:'," : ",,, . • 4. 1.1 Proper Address: ,,,,,,,, ,-;-.!:,,-t,,,c,,.:.z..--.:;-,-„,,,,•:, i .. ,,, 4,.. , t - Distric :Zone, Overlay Distric - "'''-' F 1 0 (z. E e (Y)14- -.1,, ,.,, CBDistrict SECTION 2- PROPERTY 'Elni St: District VVNERSHIP/AUTI-IORIZED AGENT 2.1 Owner of Record: 57 5 p‘ le ei rbq (") ..._ icc7t. 1(ik-a_c"r‘) s(re..1 I St-, t k \.c- \) Name (Print) Current Mailing Address: Telephone Signature . 2.2 Authorized Agent: , ' 513k CI, (CdT 1)1i Na e (Print) ( Ckid II- i( Ue,r- Current Mailing Address: ns - -s?' ?--- Sig ture A- (2 -) - t' - t r Telephone SECTION 3 -ESTIMATED CONSTRUCTION COSTS , - Item Estimated Cost (Dollars) Official Use Only - , completed by permit app ican t , ;p6rini _ Fee 1 Building _(a) Building t . (b),Ecotnirnsarte (6) „ ., 2. Electrical 3. Plumbing 4. Mechanical (HVAC) 5. Fire Protection _ Li _ check N uni b er 6. Total = (1 +2 + 3 + 4 + 5) (d-R- This Section For Official Building Permit Number Issued . . Building Commissioner/inspector of Building - - ,_. File # BP- 2013 -0148 APPLICANT /CONTACT PERSON RICHARD RIVET ADDRESS/PHONE P 0 BOX 208 CHICOPEE (413) 885 -2852 O PROPERTY LOCATION 14 GARFIELD ST MAP 17D PARCEL 064 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out 1�� �� Fee Paid /� V Typeof Construction: REPAIR/REPLACE FRONT PORCH SAME FOOTPRINT & REAR STAIRS New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 080106 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ION PRESENTED: Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. 14 GARFIELD ST BP- 2013 -0148 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 17D - 064 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: renovation BUILDING PERMIT Permit # BP- 2013 -0148 Project # JS- 2013- 000245 Est. Cost: $6400.00 Fee: $55.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: RICHARD RIVET 080106 Lot Size(sq. ft.): 15594.48 Owner: SPREI KAREN A & GARY A PADECK Zoning: URB(100)/ Applicant: RICHARD RIVET AT: 14 GARFIELD ST Applicant Address: Phone: Insurance: P 0 BOX 208 (413) 885 -2852 () CHICOPEEMA01021 ISSUED ON:8/9/2012 0:00:00 TO PERFORM THE FOLLOWING WORK:REPAIR/REPLACE FRONT PORCH SAME FOOTPRINT & REAR STAIRS POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 8/9/2012 0:00:00 $55.00 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner