11C-059 (3) Robt. W. Hall Consulting Engineers, Inc. 540 Meadow Street Ext. Agawam, MA 01001 (413) 789 -0960 CONSTRUCTION CONTROL AFFIDAVIT DATE: June 29, 2012 PROJECT TITLE: Interior Renovations PROJECT LOCATION: Leeds Elementary School, 20 Florence Street, Leeds, MA SCOPE OF PROJECT Interior Renovations of three existing first floor classrooms to accommodate Clarke Schools for Hearing & Speech programs at Leeds Elementary School IN ACCORDANCE WITH SECTION 107.3.4 OF THE MASSACHUSETTS STATE BUILDING CODE, 8TH EDITION, I, James E. Sullivan, MASS. REGISTRATION NO. 8955, BEING A REGISTERED PROFESSIONAL ENGINEER HEREBY CERTIFY THAT I HAVE PREPARED OR DIRECTLY SUPERVISED THE PREPARATION OF ALL DESIGN PLANS, COMPUTATIONS AND SPECIFICATIONS CONCERNING: ENTIRE PROJECT ARCHITECTURAL STRUCTURAL MECHANICAL FIRE PROTECTION X ELECTRICAL OTHER (specify) FOR THE ABOVE NAMED PROJECT AND THAT, TO THE BEST OF MY KNOWLEDGE, SUCH PLANS, COMPUTATIONS AND SPECIFICATIONS MEET THE APPLICABLE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE, ALL ACCEPTABLE ENGINEERING PRACTICES AND ALL APPLICABLE LAWS FOR THE PROPOSED PROJECT. I FURTHER CERTIFY THAT I SHALL PERFORM THE NECESSARY PROFESSIONAL SERVICES AND BE PRESENT ON THE CONSTRUCTION SITE ON A REGULAR AND PERIODIC BASIS TO DETERMINE THAT THE WORK IS PROCEEDING IN ACCORDANCE WITH THE DOCUMENTS APPROVED FOR THE BUILDING PERMIT AND SHALL BE RESPONSIBLE FOR THE FOLLOWING AS SPECIFIED IN SECTION 107.3.4.1: 1. Review of shop drawings, samples and other submittals of the contractor as required by the construction contract documents as submitted for building permit, and approval for conformance to the design concept. 2. Review and approval of the quality control procedures for all code - required controlled materials. ,LA.4 3. Special engineering professional inspection of critical construction components requiring -t+ , materials or construction specified in the accepted engineering practice standards 1 � = c, , Iisted in Appendix B. JAMES \�. 'LLJ ', J t KCAL , , ' . :955 / r O 1 1 P E A ° • - .NAl 1pf ' Signature On this 29th day of June, 2012, before me, the unde d notary public, personally appeared James E. Sullivan (name of document signer), proved to me through satisfactory evidence of identification, which was personal knowledge of the identity of the principle to be the person whose name is signed on the preceding or attached document in my presence. l 1Z, JOHN W. LAKE j lb _ NOTARY PUBLIC 1 :I si nature and seal of notar f ' coMMOnscs � r f ( 9 notary) r My Comm, ExpMp Mar. 21, 2010 1 M ommission expires YVL a-&C I( l , 2-0 t9 i. I Robt. W. Hall Consulting Engineers, Inc. 540 Meadow Street Ext. Agawam, MA 01001 (413) 789 -0960 CONSTRUCTION CONTROL AFFIDAVIT DATE: June 29, 2012 PROJECT TITLE: Interior Renovations PROJECT LOCATION: Leeds Elementary School, 20 Florence Street, Leeds, MA SCOPE OF PROJECT Interior Renovations of three existing first floor classrooms to accommodate Clarke Schools for Hearing & Speech programs at Leeds Elementary School IN ACCORDANCE WITH SECTION 107.3.4 OF THE MASSACHUSETTS STATE BUILDING CODE, 8TH EDITION, I, Robert F. Griffiths, MASS. REGISTRATION NO. 33161, BEING A REGISTERED PROFESSIONAL ENGINEER HEREBY CERTIFY THAT I HAVE PREPARED OR DIRECTLY SUPERVISED THE PREPARATION OF ALL DESIGN PLANS, COMPUTATIONS AND SPECIFICATIONS CONCERNING: ENTIRE PROJECT ARCHITECTURAL STRUCTURAL X MECHANICAL FIRE PROTECTION ELECTRICAL OTHER (specify) FOR THE ABOVE NAMED PROJECT AND THAT, TO THE BEST OF MY KNOWLEDGE, SUCH PLANS, COMPUTATIONS AND SPECIFICATIONS MEET THE APPLICABLE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE, ALL ACCEPTABLE ENGINEERING PRACTICES AND ALL APPLICABLE LAWS FOR THE PROPOSED PROJECT. I FURTHER CERTIFY THAT I SHALL PERFORM THE NECESSARY PROFESSIONAL SERVICES AND BE PRESENT ON THE CONSTRUCTION SITE ON A REGULAR AND PERIODIC BASIS TO DETERMINE THAT THE WORK IS PROCEEDING IN ACCORDANCE WITH THE DOCUMENTS APPROVED FOR THE BUILDING PERMIT AND SHALL BE RESPONSIBLE FOR THE FOLLOWING AS SPECIFIED IN SECTION 107.3.4.1: 1. Review of shop drawings, samples and other submittals of the contractor as required by the construction contract documents as submitted for building permit, and approval for conformance to the design concept. 2. Review and approval of the quality control procedures for all code - required controlled materials. a 3. Special engineering • r - *.nal inspection of critical construction components requiring controlled mated- iii , specified in the accepted engineering practice standards listed in Appen• • ' 4 a '"? 1 / / ii / : z 1A • / � / i . p.p., 4 i a ', ''• !X ,.. I , i / � " , �rr, • u , --: . ,: On this 29th day of June, 201 -2 ,' .r r i k' t= undersigned notary public, personally appeared Robert F. Griffiths (name of document signer), $Foxed to me through satisfactory evidence of identification, which was personal knowledge of the identity of the principle to be the person whose name is signed on the preceding or attached document in my presence. k 1,,,,... j JOHN W. t.AKE f i 1 = N OTAR Y P UBLIC " `' =y �T " CM NWEALTH OF MASSACHUSETTS ? ?, (Offic : gnature and seal of notary) = - ° t-_,..rOMM. Expires Mar. 2t, 20t9 My co mission expires 1�tA �C -� l"l p ' (g ROBT. W. HALL CONSULTING ENGINEERS, INC. Telephone (413)789 -0960 FAX (413)789 -3295 540 MEADOW STREET EXT., SUITE 2 AGAWAM, MASSACHUSETTS 01001 -0002 ;µ orgy Clarke School for Hearing & Speech At JAME :, Leeds School SUL . ✓ N CAL _ ; C J Northampton, Massachusetts ' �. � 0 8955 Y 4• 0 9 F�IStEP�� Fire Alarm System Narrative 6S S /o NAL June 27, 2012 This project consists of interior classrooms renovations to provide classroom space for Clarke School for Hearing and Speech. The existing fire alarm system is manufactured by EST. All new initiating circuits shall be connected to the existing system. A new audio visual power supply shall be provided to power the new audio /visual devices. All existing fire alarm devices in the spaces to be renovated are being removed. Provide audio /visual devices, visual only devices, smoke detectors and CO detectors as shown on the drawings. Provide CO detector in the Kindergarten -1st grade classroom. Notification appliances will be installed to ADA and NFPA guidelines. All new wiring shall be installed in conduit unless the use of limited energy cable is approved by the Northampton Fire Department. The floor plans indicate locations of all devices. The system will operate as general alarm. The initiation of any device - manual pull station or smoke detector will initiate the following conditions. a. Sound all audible devices throughout the space. b. Flash all visual signals throughout the space. c. Flash an alarm LED and sound an audible signal at the FACP. Upon Acknowledgement the alarm LED shall light steadily and the audible shall silence. Subsequent alarms shall re- initiate this sequence. d. Initiate the transmission of an alarm signal to the existing monitoring system. e. Visually indicate the alarm initiating device and location via the FACP LED display. K: \083- 5061 -12 LEEDS FTEAIENTARY \Specificarions \fire alarm narrative.doc 1 of 2 ROBT. W. HALL CONSULTING ENGINEERS, INC. Telephone (413)789 -0960 FAX (413)789 -3295 540 MEADOW STREET EXT., SUITE 2 AGAWAM, MASSACHUSETTS 01001 -0002 Clarke School for Hearin & Speech At ,e JAM' L t Leeds School LE E TRIC ICAL Northampton, Massachusetts . ‘0`4Z4' I 8955 ? � ISTEP� Fire Alarm System Narrative ! A� June 27, 2012 This project consists of interior classrooms renovations to provide classroom space for Clarke School for Hearing and Speech. The existing fire alarm system is manufactured by EST. All new initiating circuits shall be connected to the existing system. A new audio visual power supply shall be provided to power the new audio /visual devices. All existing fire alarm devices in the spaces to be renovated are being removed. Provide audio /visual devices, visual only devices, smoke detectors and CO detectors as shown on the drawings. Provide CO detector in the Kindergarten -1st grade classroom. Notification appliances will be installed to ADA and NFPA guidelines. All new wiring shall be installed in conduit unless the use of limited energy cable is approved by the Northampton Fire Department. The floor plans indicate locations of all devices. The system will operate as general alarm. The initiation of any device - manual pull station or smoke detector will initiate the following conditions. a. Sound all audible devices throughout the space. b. Flash all visual signals throughout the space. c. Flash an alarm LED and sound an audible signal at the FACP. Upon Acknowledgement the alarm LED shall light steadily and the audible shall silence. Subsequent alarms shall re- initiate this sequence. d. Initiate the transmission of an alarm signal to the existing monitoring system. e. Visually indicate the alarm initiating device and location via the FACP LED display. K \083- 5061 -12 T,FEDS FT ,F \1ENT-1RY \ Specifications \fire alarm narrarive.doc 1 of 2 ROBT. W. HALL CONSULTING ENGINEERS, INC. Telephone (413)789 -0960 FAX (413)789 -3295 540 MEADOW STREET EXT., SUITE 2 AGAWAM, MASSACHUSETTS 01001 -0002 ' Clarke School for Hearing & Speech At 0 ��� Leeds School o� S I ,A Northampton, Massachusetts EL o CTR 89 5 5 ICAL !, // Fire Alarm System Narrative June27,2012 This project consists of interior classrooms renovations to provide classroom space for Clarke School for Hearing and Speech. The existing fire alarm system is manufactured by EST. All new initiating circuits shall be connected to the existing system. A new audio visual power supply shall be provided to power the new audio /visual devices. All existing fire alarm devices in the spaces to be renovated are being removed. Provide audio /visual devices, visual only devices, smoke detectors and CO detectors as shown on the drawings. Provide CO detector in the Kindergarten-lst grade classroom. Notification appliances will be installed to ADA and NFPA guidelines. All new wiring shall be installed in conduit unless the use of limited energy cable is approved by the Northampton Fire Department. The floor plans indicate locations of all devices. The system will operate as general alarm. The initiation of any device - manual pull station or smoke detector will initiate the following conditions. a. Sound all audible devices throughout the space. b. Flash all visual signals throughout the space. c. Flash an alarm LED and sound an audible signal at the FACP. Upon Acknowledgement the alarm LED shall light steadily and the audible shall silence. Subsequent alarms shall re- initiate this sequence. d. Initiate the transmission of an alarm signal to the existing monitoring system. e. Visually indicate the alarm initiating device and location via the FACP LED display. K \083- 5061 -12 LFEDS ETE\OENTARY \ Specifications \fire alarm narrative.doc 1 of 2 Clarke School for Hearing & Speech Leeds School - Northampton, Ma. a) Method of approval required from code official that system satisfies all operational code compliance requirements — written. b) Documentation to be submitted to code officials at completion verifying that systems are in compliance with all laws, regulations and standards and pre- approved narrative reports. Robt. W. Hall, Consulting Engineers provide written confirmation c) Documentation as required by 780 CMR, Section 903.4 - Sprinkler contractor and fire alarm contractor will certify sprinkler system. Sprinkler contractor will provide record drawings. - Sprinkler contractor will provide copies of Materials, Test, Performance, and Completion certificates. d) Documentation as required by 780 CMR, Section 907.1.1.3 As Built Plans Input/output matrix Any amendments to the documents provided under 780 CMR 907.1.1.1 and 907.1.1.2 DEFINITIONS Fire Protection Systems Fire Protection Systems — Automatic sprinkler systems, fire detection system, fire alarm notification system, smoke control system, kitchen hood suppression system, etc. Building Life Safety System Building Life Safety System — A combination of fire protection systems and other building fire protection features such as automatic door closers, emergency generators, emergency egress lighting, elevator systems, etc., interconnected or integrated with multiple fire protection systems functioning simultaneously when activated. Preparer of Narrative Report — An individual who has taken charge of a project and has knowledge of required and non - required fire protection systems and buildings life safety systems. The designer I charge of a specific design for a fire protection system may prepare their portion of the Narrative Report to be submitted to the individual who has "taken charge ". The individual who has "taken charge" shall compile the data from the designer of each system and prepare a single, comprehensive and coordinated final Narrative Report describing each system and when applicable a description of how each system interfaces with the building life safety system's integration and sequence of operation. The take charge individual may be the architect, engineer of record, and the designer of any of the fire protection systems or an independent qualified consultant. Fire Protection Narrative Report Page - 8 Clarke School for Hearing & Speech Leeds School- Northampton, Ma. 4. Air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1 '/2 psi for 24 hours shall be corrected. 5. Where systems are installed in spaces that are capable of being operated at temperatures below 32 deg F, air pressure leakage tests shall be conducted at the lowest nominal temperature of the space. Underground Piping: Thoroughly flush at a rate as required by NFPA 13 -2007. Perform flushing of piping in accordance with NFPA No. 13 -2007. Underground mains and lead -in connections to system risers shall be flushed through accessible aboveground flushing outlets allowing the water to run until clear. The minimum flow rate shall be not less than one of the following: (1) Hydraulically calculated water demand rate of the system, including any hose requirements, (2) Flow necessary to provide a velocity of 10 ft/sec, (3) Maximum flow rate available to the system under fire conditions. Written test certificate shall be provided. d) Fire Alarm System 1. The fire alarm system will be inspected and tested in accordance with NFPA 72 Chapter 10 as applicable. Refer to Table 10.4.2.2. 2. At the final walk thru an Inspection and Testing form in accordance with NFPA 72, chapter 10, Section 10.6.2.3 will be delivered to the Fire Prevention Officer and to Robt. W. Hall Consulting Engineers. Refer to figure 10.6.2.3 for Inspection and Testing form. Section 2 — Equipment and Tools a) Identification of equipment and procedures to be used to verify system performance Manufacturer's instructions Specifier's special instructions - Narrative Report, sequence of operation section - Flow measuring devices — pitot for backflow flush Aerosol Smoke Product Sound level meters meeting ANSI S 1.4a, Type 2 requirements Screwdriver for removing wire from device - Communication radios Section 3 — Approval Requirements Fire Protection Narrative Report Page - 7 Clarke School for Hearing & Speech Leeds School - Northampton, Ma. Personnel a) GC shall coordinate all testing and schedule Robt W. Hall Consulting Engineers and the local authorities for witnessing the sprinkler contractor and electrical contractor's tests. b) Robt. W. Hall Consulting Engineers will require the following tests to be performed: 1. Flushing the underground main prior to system connection. 2. Robt. W. Hall, Consulting Engineers must perform a walkthrough prior to installation of any ceilings, during the construction period, as well as a walkthrough after system completion. 3. The Sprinkler Sub - Contractor shall provide a certificate of completion for the sprinlder system upon project completion. 4. Robt W. Hall will perform a final walkthrough and witness alarm tests. 5. The Fire Alarm Suppliers Technicians will provide a certificate of completion for the Fire Alarm system upon project completion. 6. Robt. W. Hall will witness the final walk thru test with the Fire Dept. c) System criteria: Wet Sprinkler System: 1. Hydrostatically tested at a pressure of 200 psi for two hours without a loss in pressure. 2. Opening of the inspectors test connection shall initiate an alarm at the main fire alarm panel and building within 90 seconds. 3. Conduct forward flow test of backflow preventer at a rate required for 4 sprinlder heads. Dry Sprinkler System: 1. Hydrostatically tested at a pressure of 200 psi for two hours without a loss in pressure. 2. Working test of the dry pipe valve shall be made by opening the inspector's test connection. System size shall be such that initial water is discharged from the system test connection in not more than 60 seconds, starting at the normal air pressure on the system and at the time of fully opened inspection test connection. Opening of the inspectors test connection shall initiate an alarm at the main fire alarm panel and building within 90 seconds. 3. Conduct forward flow test of backflow preventer at a rate required for 4 sprinkler heads. Fire Protection Narrative Report Page - 6 Clarke School for Hearing & Speech Leeds School - Northampton, Ma. 3. Closed contact will activate local alarm indication including strobes, horns and bells. 4. Closed contract will send signal through local alarm panel to central station, central station will then notify fire department. DRY SPRINKLER SYSTEM System operates automatically upon the fusing of a single fire sprinkler. Operational Sequence: 1. The activation of a single sprinkler will reduce the air pressure in the piping. The drop in air pressure will allow the dry valve to open and initiate water flow into the system. 2. The loss of pressure in the system will provide an alarm to be transmitted. 3. Closed contact will activate local alarm indication including strobes, horns and bells. 4. Closed contract will send signal through local alarm panel to notify fire department. 5. The dry valve and all alarm components that would signal a water flow are new. FIRE ALARM SYSTEM 1. The building fire alarm system shall contain smoke detection, heat detection and manual pull stations. The system utilizes ADA compliant audio /visual annunciation to notify the occupants of an alarm condition.. The activation of any manual station, water flow switch or system automatic alarm initiating device shall automatically: a. Sound all audible devices throughout the building. Audible devices shall be wired to allow for silencing while maintaining visual device activation. b. Flash all visual signals throughout the building. c. Flash an alarm LED and sound an audible signal at the Fire Alarm Control Panel. Upon Acknowledgement the alarm LED shall light steadily and the audible shall silence. Subsequent alarms shall re- initiate this sequence. d. Initiate the transmission of an alarm signal to Fire Department via the Alarm contacts tied into the existing campus main fire alarm panel. e. Visually indicate the alarm initiating device and location via the FACP LED display. f. Flash the beacon at the building. g. Mechanical unit shut down h. All installations shall be in accordance with the Amherst Fire Department. 903.1.1 (1.c) TESTING CRITERIA Section 1— Testing Criteria Fire Protection Narrative Report Page - 5 Clarke School for Hearing & Speech Leeds School - Northampton, Ma. All audible /visual devices will sound until reset at the fire alarm control panel. All alarm and trouble conditions will be sent to a UL listed central monitoring service via digital communicator. h) Duct detectors will be installed in all mechanical equipment exceeding 2000cfm. i) Carbon monoxide detectors will be installed in all classrooms. j) Provisions of the State Building Code, referenced standards, the State Fire Prevention Code and Town of Amherst by -laws are to be used. Where granted the authority, such as the location of the fire department connection and fire alarm annunciator, the Fire Department will provide operational requirements and approval. k). A Knox Box shall be provided as directed by the Amherst Fire Department and shall be keyed to the Town of Amherst. In addition, a red strobe light (at least 1,000,000 foot candles or 120 candela) must be mounted where indicated by the Fire Department and should flash upon fire alarm activation. 1) A permanently mounted framed graphic illustration of the building will be located directly above fire alarm panel). Section 5 — Features Used in the Design Methodology a) Building occupant notification and evacuation procedures The building is provided with an addressable fire alarm system. If a fire is detected either by sprinkler system flow switches or smoke detector, the building occupants will be notified via the audio /visual components of the fire alarm system. b) Emergency response personnel, site and systems features. c) Safeguards, fire prevention and emergency procedures during new construction. and impairment plans associated with existing system modifications. d) Method for future testing and maintenance of systems and documentation. 903.1.1 (1.b) SEQUENCE OF OPERATION Section 1 a) An operational description of either a system or specific devices within a system and the "resulting action" associated with the operation of the system or specific devices. WET SPRINKLER SYSTEM System operates automatically upon the fusing of a single fire sprinkler. Operational Sequence: 1. The activation of a single sprinkler will discharge water and close the contacts of a vane type flow switch. 2. Closed contact on the flow switch will provide an alarm contact for the alarm control panel. Fire Protection Narrative Report Page - 4 Clarke School for Hearing & Speech Leeds School - Northampton, Ma. Section 3 — Design Responsibility for Fire Protection Systems (sprinkler system) a) The professional engineer (PE), Robt. W. Hall Consulting Engineers, provides a partial design and specifies the design criteria to be used by the installing contractor who finalizes the system layout, and provides calculations to confirm the design criteria. The PE reviews and approves the installing contractor's final layout and calculations. The PE is considered the engineer of record and certifies system installation for code compliance at completion. Section 4 — Fire Protection Systems to be installed Sprinkler System a) New Water supply and fire mains. b) New Automatic sprinlder systems and components. c) New Automatic sprinkler systems and components — building will be provided with sprinkler coverage. System is designed in accordance with NFPA 13 -2007. d) Water supply and fire mains. A new 6" main will be provided for the fire service. The building is a mix of light and ordinary hazard occupancies. The systems will be hydraulically designed. The light hazard areas will be based on 0.1 gpm/sf over the hydraulically most remote 1500 sf, and the ordinary group I areas will be designed for 0.15 gpm/sf over the hydraulically most remote 1500 sf. The light hazard areas will include a 100 gpm exterior hose stream allowance and the ordinary hazard areas will include a 250 gpm hose allowance. Quick response sprinklers are used throughout the building. The application areas for the sprinlder system will be reduced based on ceiling height in accordance with NFPA 13- 11.2.3.2.3. Minimum flows of sprinklers to be in accordance with manufacturers listing. e) Seismic considerations — sprinkler system shall be seismically braced. Fire Alarm System a) The fire alarm system is an addressable system. The building will be completely covered with detection in all areas. b) The fire alarm panel control panel will be located in the main entrance lobby. A Knox box and beacon will be located outside the lobby. c) Fire alarm systems and components — audio and visual appliances installed throughout in accordance with NFPA 72. d) Notification appliances will be installed to ADA and NFPA guidelines. e) The floor plans indicate locations of all devices. f) The system will operate as general alarm. The initiation of any device, manual pull station, heat or smoke detector or sprinkler flow will initiate a general alarm condition. Fire Protection Narrative Report Page - 3 Clarke School for Hearing & Speech Leeds School - Northampton, Ma. FIRE PROTECTION SYSTEMS NARRATIVE REPORTS Project Summary This project involves a partial sub - division of classrooms for use by the Clarke School for Hearing and Speech. The The building has one zone for water flow for the wet system, and a separate zone for the dry system. 903.1.1 (1.a) BASIS (METHODOLOGY) OF DESIGN Section 1- Building Description a) Building "Use " - Group E - Educational b) Building height - approximately 34' -0" inches. c) Number of floors above grade -2 d) Number of floors below grade -0 e) Square footage per floor, first floor: 8,775 sq. ft., second floor 3,906 sq. ft. f) Building Construction Type. The building is type V -B construction. g) Type(s) of occupancies (hazards) within the building - classroom, office, mechanical. h) High storage of commodities within a building usually over 12 ft. - none Section 2 - Applicable Laws, Regulations and Standards a) The 8 Edition of 780 CMR code sections "Fire Protection System Requirements" 903.2.1.2 requires sprinkler protection - 903.4 requires Audible and Visual Alarms throughout the building - 905.3.1 does not require standpipes. 907.2.1 requires a Manual Fire Alarm system - 907.3.1 requires duct detectors 907.4.1 requires a smoke detector at the main fire alarm control panel - 907.5 requires Alarm Notification Appliances 907.6.2 requires a secondary power supply in accordance with NFPA 72 - 907.6.5 requires Monitoring of the Automatic Sprinkler systems and Fire Alarm and Detection Systems in accordance with NFPA 72. b) NFPA Standards and Edition used for design of each specific fire protection system - NFPA 13 "Sprinkler Systems ", 2007 ed NFPA 24 "Underground fire service mains" NFPA 72 "National Fire Alarm Code. ", 2007 c) Applicability of specialized codes (plumbing, elevator, and electrical, architectural access) - 521 CMR, Architectural Access Board Fire Protection Narrative Report Page - 2 Clarke School for Hearing & Speech Leeds School- Northampton, Ma. Fire Protection Construction Documents Narrative Report for Renovations at Leeds School For Clarke School for Hearing & Speech Northampton, Massachusetts By Robt. W. Hall Consulting Engineers, Inc. 540 Meadow Street Ext. Agawam, MA 01001 Tel: (413) 789 -0960 June 27, 2012 Fire Protection Narrative Report Page - 1 A.EDGIN ALA., N Pi JAMES H M. HANIFAN ALA.. NQ.AR B KENNETH R. JODRIE A.I.A., LEED AP BERTRAM W. GARDNER IV, ALA NC ARB CAOLO & BIENIEK ASSOCIATES, INC. A R C H I T E C T U R E • P L A N N I N G • I N T E R I O R D E S I G N CONSTRUCTION CONTROL CERTIFICATION For Project Title: Interior Renovations Date: June 27, 2012 Project Location: Leeds Elementary School, 20 Florence Street, Leeds, MA Scope of Project: Interior renovations of three existing first floor classrooms to accommodate Clarke Schools for Hearing & Speech programs at Leeds Elementary School. In accordance with SECTION 107.3.4 of the 8th edition of the Massachusetts State Building Code: I, Curtis A. Edgin, Mass. Registration Number 7352, being a registered professional Engineer /Architect hereby agree to act as the design professional in responsible charge for the above referenced project. As such, I certify that I have prepared or directly supervised the preparation of all design plans computations and specifications concerning: Architectural ❑ Structural ❑ Mechanical ❑ Fire Protection ❑ Electrical ❑ Other (specify) I further agree, as the design professional in responsible charge, that I have reviewed and coordinated all documents prepared by others, including phased and deferred submittal items, for compatibility with the design of the building, as required by 780 CMR, Section 107.3.4.1 In addition I agree to perform the necessary professional services and be present on the construction site on a regular and periodic basis to determine that the work is proceeding in accordance with the documents approved for the building permit. Services shall include: 1. Review, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals as specified in Chapter 17. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the construction documents and this code. Signature and Seal of registered professional:, ••.. A f 362 _ till • MA On this 27th day of June, 2012, before me, the undersigned notary public, personally appeared Curtis A. Edgin (name of document signer), proved to me through satisfactory evidence of identification, which was personal knowledge of the identity of the principal, to be the person whose name is signed on the preceding or attached document in my presence. (Offici. J ignature and seal of notary) My commission expires October 20, 2017 `:21 East Sheet • Chicopee, Tv1assacilu5e is 01020 4176 • (413) 594 -2500 • Fax 413) , 24 25C0 • into 7ctaarchliects.nel _ e ' c__/4 eeiV74 4 4 I mAI-e-e& \ ett. (9/6/ ,9 tqazfit, 7,907 : JANE SWIFT 1 677)/27,9200 Govemor /. JANE PERLOV c/ er. 677)7.27-79.2 Secretary JOSEPH S. LALLI Commissioner Construction Debris Disposal Affidavit (required for all demolition and renovation work) In accordance with the sixth edition of the State Building Code, 780 CMR section 111.5 Debris, and the provisions of MGL c 40, S 54; Building Permit # is issued with the condition that the debris resulting from this work shall be disposed of in a properly licensed waste disposal facility as defined by MGL c 111, S 150A. The debris will be transported by: Garland Construction Corporation (name of hauler) The debris will be disposed of in : Waste Management of Western Mass. (name of facility) New Ludlow Road Granby 01033 (address of facility) Signature ' .ernra applicant l( date debrisa(r.doc Ac CERTIFICATE OF LIABILITY INSURANCE 7/5/2012 DATE(MMD/YYYY) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: James J. Dowd & Sons Ins PHONE FAX 14 Bobala Road (A/C,No,Ext): 538 - 7444 (A /C,No):413 536 - 6020 Holyoke MA 01040 ADDRESS: PRODUCER CUSTOMER ID #: INSURER(S) AFFORDING COVERAGE NAIC # _ INSURED INSURER A :ACadia Insurance Company 31325 Garland Construction Corporation 40 Old James Street INSURER B: Chicopee MA 01020 INSURERC: INSURER D : INSURER E : INSURER F : COVERAGES CERTIFICATE NUMBER: 744897408 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR INSR WVD POLICY NUMBER (MMIDD/YYYY) (MM /DD/YYYY) A GENERAL LIABILITY Y CPA005404922 7/18/2011 7/18/2012 EACH OCCURRENCE $1,000,000 DAMAGE TO RENTED X COMMERCIAL GENERAL LIABILITY PREMISES (Ea occurrence) $300,000 CLAIMS -MADE X OCCUR MED EXP (Any one person) $15,000 PERSONAL &ADV INJURY $1,000,000 GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP /OP AGG $2,000,000 POLICY PRO- LOC $ JECT A AUTOMOBILE LIABILITY Y MAA004293123 7/18/2011 7/18/2012 COMBINED SINGLE LIMIT $1,000,000 (Ea accident) ANY AUTO BODILY INJURY (Per person) $ X ALL OWNED AUTOS BODILY INJURY (Per accident) $ X SCHEDULED AUTOS PROPERTY DAMAGE $ X HIRED AUTOS (Per accident) X NON -OWNED AUTOS $ A X UMBRELLA LIAB X OCCUR Y CUA004292823 7/18/2011 7/18/2012 EACH OCCURRENCE $2,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $2,000,000 DEDUCTIBLE _ $ RETENTION $ $ A WORKERS COMPENSATION WCA004290823 7/18/2011 7/18/2012 X WC STATU- OTH- AND EMPLOYERS' LIABILITY TORY LIMITS FR Y / N ANY PROPRIETOR/PARTNER/EXECUTIVE E.L. EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? N N I A (Mandatory in NH) E.L. DISEASE - EA EMPLOYEE $1,000,000 If yes, describe under DESCRIPTION OF OPERATIONS below E.L. DISEASE - POLICY LIMIT $1,000,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (Attach ACORD 101, Additional Remarks Schedule, if more space is required) Certificate Holder is Additional Insured per written contract on General Liability, Auto and Umbrella (Umbrella is follow form) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. City of Northampton 210 Main Street Northampton MA 01060 AUTHORIZED REPRESENTATIVE © 1988-2009 ACORD CORPORATION. All rights reserved. ACORD 25 (2009/09) The ACORD name and logo are registered marks of ACORD of y _ The Commonwealth of Massachusetts Pant Form Department of Industrial Accidents pi =: l Office of Investigations o 1 Congress Street, Suite 100 -- Boston, MA 02114 -2017 74, v www.mass.gov /dia Workers' Compensation Insurance Affidavit: Builders /Contractors/Electricians /Plumbers Applicant Information Please Print Legibly Name ( Business /Organizati /Individual): Garland Construction Corporation Address: 40 Old James Street City /State /Zip: Chicopee, Ma. 01020 Phone #: 413 533 7699 Are you an employer? Check the appropriate box: Type of project (required): 1. ✓Q I am a employer with 19 4. E 1 am a general contractor and I 6. New construction employees (full and /or part- time).* have hired the sub - contractors 2. ❑ I am a sole proprietor or partner- listed on the attached sheet. 7. rJ Remodeling ship and have no employees These sub - contractors have 8. ri Demolition working for me in capacity. employees and have workers' g any p Y . 9. 0 Building addition [No workers' comp. insurance comp. insurance.: required.] 5. [] We are a corporation and its 10.0 Electrical repairs or additions 3. ❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.D Roof repairs insurance required.] + c. 152, § 1(4), and we have no employees. [No workers' 13.0 Other comp. insurance required.] *Any applicant that checks box #1 must also fill out the section below showing their workers' compensation policy information. I Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub - contractors and state whether or not those entities have employees. If the sub - contractors have employees, they must provide their workers' comp. policy number. I am an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Acadia Insurance Company Policy # or Self -ins. Lic. #: WCA004290823 Expiration Date: 7/18/12 Job Site Address: 21 Florence Stre C /S tate /Zi p: L ee d s, M a. 01053 T Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and /or one -year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pgns an , nalties of erjury that the information provided above is true and correct. I Signature: 0 __ .7 .,, ,,,. "�7 Date: 7 /6/12 Phone #: 413 533 769 Official use only. Do not write in this area, to be completed by city or town officiaL City or Town: Permit/License # Issuing Authority (circle one): 1. Board of Health 2. Building Department 3. City /Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone #: Ma..achu•ett• - Uel)artrnent of Public Safet■ j Board of Ruildinu Retulation. and'tandard. 1.1 Construction Supervisor License License: CS 13888 EDWARD L ORWAT 40 OLD JAMES ST f CHICOPEE, MA 01020 -- ✓ � Expiration: 8/7 /2013 < .nnui�Ki.utr Tr#: 20289 Versionl.7 Commercial Building Permit May 1 5, 2000 SECTION 10- STRUCTURAL PEER REVIEW (780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes No SECTION 11 - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT David Pomerantz, Director of Central Services I, ... , as Owner of the subject property Garland Construction Corporation here( authorize to act o e - f, itt .11 a -rs relative to work authorized by this building permit application. 7/ Signat e • O '�, Date Via Daniel ',mat, President of Garland Construction Corporation , as Owner /Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Daniel Orwat P,tint..Name 7/1 Signature of gent Date SECTION 12 - CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder Edward L. Orwat CSL 3888 License Numb 40 Old James Street Ch • . ee, Ma 01020 8 / 1 3/ 1 Address / Expiration Date ,, 4 533 - 7699 Signature Telephone SECTION 13 - WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes No Version1.7 Commercial Building Permit May 15, 2000 SECTION 9- PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES - FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116 (CONTAINING MORE THAN 35,000 C.F. OF ENCLOSED SPACE) 9.1 Registered Architect: .. .... n� . Not Applicable ❑ see attached construction control documents Name (Registrant): see attached construction control documents Registration Number Address Expiration Date Signature Telephone 9.2 Registered Professional Engineer(s): see attached Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor Garland Construction Corporation Not Applicable ❑ Company Name: `Michael Avis Responsible In Charge of Construction 40 Old J. I es Street Chico %e� , M-� 01020 Address 4 .4 533 -7699 Sign'e � Telephone Versionl.7 Commercial Building Permit May 15, 2000 8. NORTHAMPTON ZONING Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size NA NA Frontage NA .. NA _. .. .._ Setbacks Front NA Side L: R:_ Rear NA Building Height '34' Bldg. Square Footage NA Open Space Footage (Lot area minus bldg & paved NA # of Parking Spaces Fill: (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO 0 DONT KNOW 0 YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW YES 0 IF YES: enter Book Page and /or Document # ". B. Does the site contain a brook, body of water or wetlands? NO 0 DONT KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES 0 NO IF YES, describe size, type and location: !;'School D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. Version1.7 Commercial Building Permit May 15, 2000 SECTION 4- CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations ID Existing Wall Signs ❑ Demolition ❑ Repairs ❑ Additions ❑ Accessory Building ❑ Exterior Alteration ❑ Existing Ground Sign ❑ New Signs ❑ Roofing ❑ Change of Use ❑ Other ❑ Brief Description Renovate 3 existing classrooms to accommodate layout plans for new classrooms per attached Of Proposed Work: architectural drawings. SECTION 5 - USE GROUP AND CONSTRUCTION TYPE USE GROUP (Check as applicable) CONSTRUCTION TYPE A Assembly A -1 ❑ A -2 ❑ A -3 ❑ 1A 1 ❑ A -4 ❑ A -5 ❑ 1B D B Business ❑ 2A ❑ E Educational 0 2B 1 ❑ F Factory ❑ F -1 ❑ F -2 ❑ 2C ❑ H High Hazard ❑ 3A ❑ 1 Institutional ❑ 1 -1 ❑ 1 -2 ❑ 1 -3 ❑ 3B ❑ M Mercantile ❑ 4 ❑ R Residential ❑ R -1 ❑ R -2 ❑ R -3 ❑ 5A ❑ S Storage ❑ S -1 ❑ S -2 ❑ 5B [ ❑ U Utility ❑ Specify: M Mixed Use ❑ Specify: S Special Use ❑ Specify: ` COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS, ADDITIONS AND /OR CHANGE IN USE Existing Use Group: `Educational Proposed Use Group: Educational Existing Hazard Index 780 CMR 34): ` . _ ... „. _______ Proposed Hazard Index 780 CMR 34): SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor (sf) 1 2,300 st 1 �..� _ __... _ ... 2nd .. 2 3,906 3rd rd 4 th 4 Total Area (sf) Total Proposed New Construction (sf) Total Height (ft) Total Height ft 7. Water Supply (M.G.L. c. 40, § 54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System: Public p Private ❑ Zone Outside Flood Zone p Municipal p On site disposal system Is Versionl.7 Commercial Building Permit May 15, 2000 s,4 45,E onty City of Northampton :lotus of Peartit -- 4 Building Department Ctirb C u f , 212 Main Street S ewer t a ®= 1,Y .1 = ;silty ,' , 4 Z Room 100 v ' x .1 Availability - % . \ ) c � �- � , N hampton, MA 01060 :sits, of Structure t lf;, F P.' 13- 587 -1240 Fax 413 - 587 -1272 mite Plans, � o� 0 v Othe , i CATION TO CONSTRUCT, REPAIR, RENOVATE, CHANGE THE USE OR OCCUPANCY OF, OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING SECTION 1 SITE INFORMATION 1.1 Property Address This section to be completed by office Leeds Elementary School ` Map Lot Unit 21 Florence Road Leeds, Ma. 01053 Zone Overlay District i ___ __.._. - Elm St. District CB District SECTION 2 PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: City of Northampton 210 Main Street Name (Print) Current Mailing Address: 587 -1249 Signature Telephone 2.2 Authorized Agent: Central Services Department 240 Main Street Name (Print) Current Mailing Address: 587 -1238 Signature Telephone SECTION 3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building $87,242.00 (a) Building Permit Fee 2. Electrical $28,800.00 (b) Estimated Total Cost of Construction from (6) _.. _.. .. . 3. Plumbing 1 $5,500.00 Building Permit Fee 4. Mechanical (HVAC) . ___, 5. Fire Protection € $63 v 6. Total = (1 + 2 + 3 + 4 + 5) . , : • • Check Number • 0 1 to 1 g I O a This Section For Official Use Only Building Permit Number Date Issued Signature: Building Commissioner /Inspector of Buildings Date File # BP- 2013 -0047 APPLICANT /CONTACT PERSON GARLAND CONSTRUCTION CORP kruiRaC 67 ADDRESS/PHONE 40 Old James St CHICOPEE (413) 533 -7699 H W 1-141 C UCC4, PROPERTY LOCATION FLORENCE ST - LEEDS SCHOOL MAP 11C PARCEL 059 001 ZONE URA(100)/ £LECI r t c ! t °A pc oP VIE (Ai 4-9 THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST CON CT" Ptzo J t ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out 611.240.i � y� MO ' j P ( ( K LEA Fee Paid / J / �, 2 -� $ ysTF ►i Tvpeof Construction: RENOVATE 3 CLASSROOMS FOR CLARKE SCHOOL New Construction f E rC [ ,7 N 1T VIA Non Structural interior renovations Addition to Existing, Accessory Structure FAP A i Building Plans Included: g 12-I 1'2- -. Owner/ Statement or License 13888 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON o 5P tW' 1< ' 11,/ I7 04MATION PRESENTED: 5 pproved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management Demolition Delay V Z Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. FLORENCE ST - LEEDS SCHOOL BP- 2013 -0047 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 11C - 059 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: renovation BUILDING PERMIT Permit # BP- 2013 -0047 Project # JS- 2013- 000046 Est. Cost: $184829.00 Fee: $1108.80 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: GARLAND CONSTRUCTION CORP 13888 Lot Size(sq. ft.): 217800.00 Owner: NORTHAMPTON CITY OF Zoning: URA(100)/ Applicant: GARLAND CONSTRUCTION CORP AT: FLORENCE ST - LEEDS SCHOOL Applicant Address: Phone: Insurance: 40 Old James St (413) 533 -7699 Workers Compensation CHICOPEEMA01020 ISSUED ON :8/3/2012 0 :00 :00 TO PERFORM THE FOLLOWING WORK: RENOVATE 3 CLASSROOMS FOR CLARKE SCHOOL POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 8/3/2012 0:00:00 $1108.80 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner