Loading...
38A-137 24. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5' from the duct outlet for all fireplaces 25. Fire and draft stopping shall be completed before rough inspection. 780 CMR R302. 26. Ignition barriers in place before final. 780 CMR R316. 27. Dwelling /Garage fire separation. An attached garage (within 3' of main structure) is required to have %2 drywall on the garage side of the separation wall and if there is a finished space above the garage all walls must have %2 drywall and the ceiling 5/8" drywall. 780 CMR R302.6 28. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. Energy information including mechanical equipment posted on the electric panel. d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Building Option Package. 29. Vapor retarders. Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer (diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99% of the moisture in a structure. This is evident every time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 30. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 31. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note: ThruLoks are engineered for post attachment supporting a railing. 32. Smoke and CO detectors as required. 780 CMR R314 and R315. 33. Closets beneath stair which have doors must be drywalled with 'A". 780 CMR R302.7 Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. My email address is: cmillerna northamptonma.gov Thank you for your c n on these at ers. Chuck Miller City of Northampton Assistant Commissioner and Zoning Enforcement 9. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1/ 1 780 CMR R802.3.1 10. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 11. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and number of jack studs required. 12. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss 13. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 14. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basements, 6'4" at beams /ducts. 780 CMR R305.1. MA amended 15. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4 16. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. Order restrictors. 780 CMR R612.2 17. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape. 780 CMR R310 b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft at 1 floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 3/4" from the top of the threshold and only in- swinging doors. 780 CMR R311.3 18. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ", maximum riser 8 % ", maximum overall variance for the run is 3/8 ", 4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception, 4 3/8" on balustrade, 6" in the triangle. Graspable rail 1 %" minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 19. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36 ", 4" sphere rule. 780 CMR R312.1. 20. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In interior non - bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1 %' 16ga. strap must extend a minimum of 6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom. Notches are different. 21. Dryer duct transition is limited to 8' of aluminum flex and must be exposed. 780 CMR M1502.4.3 22. Dryer duct maximum equivalent length is 25' or per manufacturer's specs. 780 CMR M1502.4.4.1, no screwed connections. 23. Markup air is required for any exhaust hood of 400 CFM or more. 780 CMR M1503.4 City of Northampton R :ti" a c , y e, . # < Massachusetts I DEPARTMENT OF BUILDING INSPECTIONS "" 212 Main Street • Municipal Building '� , �^ 4 " Northampton, MA 01060 45 l irk' 4 INSPECTOR Kent Pecoy & Sons Construction July 3, 2012 215 Baldwin Street West Springfield, MA 01089 Subject Location: 107 Moser Street Map Block: 38A-1:Z8 "? c Mr. Pecoy, Please follow up on the following items: 1. Stamped structural drawings are required for all none code prescriptive framing. Some examples are I- joist, LVLs, floor or roof truss. 2. Braced wall detailing is needed for the front of the garage as shown requires 4200 lbs. embedded anchors. 3. The garage ridge will need to be structural if there are not ceiling joist or rafter ties. 4. A smoke /CO detector is required at the bottom of every stair leading to a finished floor above. 5. Plane shows 7/16 exterior sheathing, but states 1" structural foam board? 6. Northampton is a stretch energy code town therefore a HERS rating is required. a. Any air permeable insulation must be in a sealed cavity. This needs to be done before rough inspection. b. All penetration in the ceiling must be sealed before attic insulation is installed; an air sealing inspection is required. c. Please be aware of requirements the Thermal Bypass Checklist. 7. Plumbing pipes in walls are challenging to meet code see item 18 below. 8. Planning Decision Hearing conditions of approval # 2, 9, 12, and 13. Proof of completion required. 9. Confirmation of Water and Sewer permits. As of August 4 2011 the 8 Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8 Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I soils (table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. 5. Through wall form ties must be removed from both faces and patched with hydraulic cement. 780 CMR R406.2 of amendments. 6. Foundation anchor bolts must be %2" and be embedded a minimum of 7" into the concrete. 10" bolts! 780 CMR R403.1.6 7. CMU foundations require 3/8" parging before damp proofing. 780 CMR R406.1 see exceptions. 8. Ceiling joist are intended to prevent spread, once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8 -16nd common are required at each connection. 780 CMR R802.3.1. When there is neither of these a structural ridge is required with a load path to the foundation. • o �TtIA�1 r + 1 i • a e . y )1:41 (fib Narillantr.f tail DEPARTMENT OF BUILDING INSPECTIONS ,INSPECTOR 212 Main Street ®Msmicipal Building Northampton, MA 01060 101 LOCATION /14°Y611" - 61 ---- - - - - -_ SQUARE FOOTAGE AMOUNT BASEMENT @ _ 20 9 3 y 1860, 7 • 1 @ .j0 3 L q 6 71 o J FLOORS, FINISH ATTIC, GARAGE @ 20 < ' • DECK/PORCIS @ .20 11'1 9, 6o : TOTAL_. g9 J `1/ AA A p ,wt • z cal) • • • • CI REScheck Software Version 4.4.2 Comp Cert Project Title: Yorkshire model Village Hill Energy Code: 2009 IECC Location: Northampton, Massachusetts Construction Type: Single Family Glazing Area Percentage: 9% Heating Degree Days: 6404 Climate Zone: 5 Construction Site: Owner /Agent: Designer /Contractor: 137 Moser Street Kent Pecoy Kent Pecoy and Sons Construction Village Hill Sturbridge Development Northampton, MA 215 baldwin Street West Springfield, MA 01089 Compliance: Passes using UA trade -off Compliance: 12.4% Better Than Code Maximum UA: 186 Your UA: 163 The % Better or Worse Than Code index reflects how close to compliance the house is based on code trade -off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Gross Cavity Cont. Glazing UA Assembly Area or R -Value R -Value or Door Perimeter U- Factor Ceiling 1: Flat Ceiling or Scissor Truss 934 59.0 0.0 22 Wall 1: Wood Frame, 16" o.c. 1664 26.0 0.0 76 Window 1: Vinyl Frame:Double Pane with Low -E 158 0.300 47 Door 1: Solid 18 0.300 5 Door 2: Solid 18 0.300 5 Basement Wall 1: Solid Concrete or Masonry 123 0.0 10.0 8 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building bee de 'g d to meet the 2009 IECC requirements in REScheck Version 4.4.2 and to comply with the mandatory requirements ' d in a check Inspection Checklist. Name - Title Signature Date Project Title: Yorkshire model Village Hill Report date: 06/29/12 Data filename: Untitled.rck Page 1 of 1 QUICK ANALYSIS REPORT Date: June 29, 2012 Rating No.: 057 -12 Building Name: Village Hill #2 Rating Org.: Power House Energy Consulting Owner's Name: Phone No.: 413 - 835 -5162 Property: Lot #11 Moser St Raters Name: Matt Turcotte Address: Northampton, MA01060 Rater's No.: 1497133 Builder's Name: Pecoy Companies Weather Site: Northampton, MA Rating Type: Based On Plans File Name: 057 -12 Moser St #2 plans.blg Rating Date: 6/28/12 Codes Programs IECC 2009 Performance: Fails EPA ENERGY STAR 2.0 Passes IECC 2006 Performance: Passes EPA ENERGY STAR 2.5 Passes IECC 2004 Performance: Passes EPA ENERGY STAR 3.0 Fails IECC 2003 Performance: Passes Tax Credit Passes IECC 2001 Performance: Passes HERS Index 55 IECC 2000 Performance: Passes IECC 1998 Performance: Passes ECC of NY Performance: Passes ECC of NV Performance: Fails MEC 1995 Performance: Passes MEC 1993 Performance: Passes MEC 1992 Performance: Passes ASHRAE 90.2 Performance: Passes REM /Rate - Residential Energy Analysis and Rating Software v12.96 This information does not constitute any warranty of energy cost or savings. © 1985-2011 Architectural Energy Corporation, Boulder, Colorado. A ° R°® CERTIFICATE OF LIABILITY INSURANCE 4ATE(MM/DDI1'YYY) /24/2012 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Irene Balise NAME: Alexander W Borawski Inc PHONE ^ NE F:tr (413)586 -5011 .No1: (413)586 -7973 88 Ring Street, Suite B E -MAIL ADDRESS: ibalise @borawskiinsurance.com INSURER(S) AFFORDING COVERAGE NAIC # Northampton MA 01060 -3257 INSURER A :Netherlands Insurance 24171 INSURED INSURERB :Peerless Insurance 24198 Kent Pecoy & Sons Construction, Inc INSURER C :Mass Employers Ins. Co. 215 Baldwin St INSURER D : INSURER E : West Springfield MA 01089 INSURERF: COVERAGES CERTIFICATE NUMBER:CL1172200146 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR INSR WVD POLICY NUMBER (MM/DD/YYYY) (MMIDD/YYYY) GENERAL LIABILITY EACH OCCURRENCE $ 1, 000, 000 X COMMERCIAL GENERAL LIABILITY DAMAGE TO RENTED PREMISES (Ea occurrence) $ 100,000 A CLAIMS -MADE X OCCUR CBP8780556 7/1/2011 7/1/2012 MEDEXP(Anyoneperson) $ 5,000 PERSONAL &ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP /OP AGG $ 2,000,000 T1 POLICY n !T pi r LOC $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT (Ea accident) 1000000 ANY AUTO BODILY INJURY (Per person) $ B ALL OWNED X SCHEDULED BA8781850 7/1/2011 7/1/2012 BODILYINJURY(Peraccident) $ AUTOS AUTOS X HIRED AUTOS X NON -OWNED' PROPERTY DAMAGE $ _ AUTOS (Per accident) _ Underinsured motorist B1 split $ X UMBRELLA UAB X OCCUR EACH OCCURRENCE $ 5,000,000 B EXCESS LIAB CLAIMS -MADE AGGREGATE _$ 5,000,000 DED X (RETENTION$ 10,000 CU8783651 7/1/2011 7/1/2012 $ C WORKERS COMPENSATION 1 W CY LIMITS! TU- I TH AND EMPLOYERS' LIABILITY Y / N ANYICEOPRIIETORPARTNE /EXECUTIVE N N E.L. EACH ACCIDENT $ 500,000 (Mandatory in NH) MCC2000239012011 6/30/2011 6/30/2012 E.L. DISEASE - EA EMPLOYEE $ 500,000 If yes, describe under DESCRIPTION OF OPERATIONS below E.L. DISEASE - POLICY LIMIT $ 500, 000 DESCRIPTION OF OPERATIONS 1 LOCATIONS 1 VEHICLES (Attach ACORD 101, Additional Remarks Schedule, if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN City of Northampton ACCORDANCE WITH THE POLICY PROVISIONS. 212 Main Street Northampton, MA 01060 AUTHORIZED REPRESENTATIVE R Borawski /BORIB1 �� > - ACORD 25 (2010/05) ©1988 -2010 ACORD CORPORATION. All rights reserved. INS025 i2mnnsl nt Tha Arnim nomc and Irwin =ro rcniafnror1 mmirirc of arnb l SECTION 8 - CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder : )< i c c C `i - ' ri License Number :� 1'i .I f u�„ C ;, C �,i„�•�iv.�r� i ��if� C;L( ' i f /J6lac l) Address Expiration Date NI?, 7 g I - Signature Telephone 9. Realstered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number tn i'. Win.;, - i PIA Cic Ci 71- 1110.cia Address 1 ' Expiration Date Telephone `'( /;; - 7P / cF. SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes No ❑ 11. — Home Owner Exemption The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -near period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) New House ® Addition Replacement Windows Alteration(s) ❑ Roofing J Or Doors G Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [p Siding [❑] Other [0] Brief Description of Proposed Work: j, 4..t �Jc " a � c: ;�: e :1, Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative_ Renovating unfinished basement Yes No Plans Attache (Rolf' - Sheet 6a. If New house and or addition to existing housing. complete the following: a. Use of building : One Family x Two Family Other b. Number of rooms in each family unit: Number of Bathrooms 1%2 c. Is there a garage attached? d. Proposed Square footage of new construction. [ CC SF Dimensions e. Number of stones? a, f. Method of heating? F;,-cc.--d H /4 Fireplaces or Woodstoves X. `o Number of each -- g. Energy Conservation Compliance., Masscheck Energy Compliance form attached? cc h. Type of construction f- rcti,e- i. Is construction within 100 ft. of wetlands? Yes < No. Is construction within 100 yr. floodplain Yes X No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? ,J Yes No . I. Septic Tank City Sewer b( Private well City water Supply b( SECTION 7a - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Pe <<; • , as Owner of the subject property hereby authorize {; , K r r)c, es4 to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of r Date 40/c4w. / I ?c si , as Owner /Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. /ti 1 i� ,,,; Print Name d Signature of Owner /Agent Dated // / ict n�o .� Section 4. ZONING All Information Must Be Completed. PertRit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage Open Space Footage (Lot area minus bldg & paved parking) # of Parking Spaces Fill: (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO ® DONT KNOW 0 YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW 0 YES IF YES: enter Book Page and /or Document # B. Does the site contain a brook, body of water or wetlands? NO ® DONT KNOW ® YES ® IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained ® Obtained ® ,Date Issued: C. Do any signs exist on the property? YES ® NO ® IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES ® NO IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES ® NO ;�� IF YES, then a Northampton Storm Water Management Permit from the DPW is required. cLA ► a Cori 4914/ fi-vr_c Department use only City of Northampton Status of Permit: Building Department Curb Cut/Driveway Permit 212 Main Street Sewer /Septic Availability Room 100 Water/Well Availability Northampton, MA 01060 Two Sets of Structural Plans phone 413 - 587 -1240 Fax 413 - 587 -1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE INFORMATION 1.1 Property Address: TThls section to be completed by office /07 Move- - l Map 3 19- Lot ) / Unit a. w +'rlr / L i L ✓T Zone Overlay District Elm St. District CB District SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: Keftt Pcea� &�� �jnSj-rvt_iierrti L,.'. �• ir� ?ic( P )1 - 1 Name (Print) Current Mailing Address: r tir3 7A/ - `7Cc` Telephone Signature 2.2 Authorized Anent: S r L -(, 1`11 ciceq Name (Print) Current Mailing Address: r 1 113- 3t"�{- 68`f Signature Telephone SECTION 3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building (a) Building Permit Fee (FI, 65c 2. Electrical (©_ +-ISo (b) of Construction from (6) _ 3. Plumbing /0, 37 Building Permit Fee 4. Mechanical (HVAC) 13, '75 c 5. Fire Protection . Z co- 6. Total = (1 + 2 + 3 + 4 + 5) a i o Check Number This Section For Official Use Only Date Building Permit Number: ,-/ d Issued: .4111 ,,,a _4111 Signature: U / / % //A. Building Commissioner /Inspector of Buildings Date File # BP- 2012 -0930 APPLICANT /CONTACT PERSON KENT PECOY & SONS CONSTRUCTION INC ADDRESS /PHONE 215 BALDWIN ST WEST SPRINGFIELD (413) 781 -7008 PROPERTY LOCATION 107 MOSER ST MAP 38A PARCEL 137 001 ZONE PV THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT _ 3 3 7 7 giT Fee Paid v Building Permit Filled out _ _ ,� .' , 1 , ,,TA, Fee Paid Typeof Construction: CONSTRUCT 2 STORY SFH W /ATT GARAGE/DECK New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 3 sets of Plans / Plot Plan THE F LOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON I F ATION PRESENTED: Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management De. Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. 107 MOSER ST BP-2012-0930 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38A - 137 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: New Single Family House BUILDING PERMIT Permit # BP-2012-0930 Project # JS- 2012 - 001620 / D O74. � Est. Cost: $218200.00 310 Fee: $916.40 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: KENT PECOY & SONS CONSTRUCTION INC_ Lot Size(sq. ft.): 4378.00 Owner: KENT PECOY & SONS CONSTRUCTION INC Zoning: PV Applicant: KENT PECOY & SONS CONSTRUCTION INC AT: 107 MOSER ST Applicant Address: Phone: Insurance: 215 BALDWIN ST (413) 781 -7008 WEST SPRINGFIELDMA01089 ISSUED ON:7/10/2012 0:00:00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT 2 STORY SFH W /ATT GARAGE /DECK POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 7/10/2012 0:00:00 $916.40 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner