Loading...
23D-159 (6) INSURANCE COVERAGE: have a current Jiahltity insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes EP No ❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy lam' Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee rtnPS not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws, and that my signature on this permit application waivPsthis requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this box❑, I hereby certify that all of the details and information I have submitted (or entered) regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO Progrevs Incpeetions Date r'ommentc Final tncpertinn Date r'nmmPnts. Type of License: By ❑ Master Title ❑ Master - Restricted City/Town ❑Joumeyperson Signature of Licensee Permit # ❑Journeyperson- Restricted License Number: Fee $ ❑ Check at www macs gnv/dpt Inspector Signature of Permit Approval Commonwealth of Massachusetts 2 3 2012 City Of Northampton �y r NG, : 0 T j� pEP7 Sheet Metal Permit Permit # (sin-id-0 O' 1 N OPTHAMPTO ', 80 Estimated Job Cost: $ 5 00 Permit Fee: $ 132 0 lg-6 Plans Submitted: YES NO fr Plans Reviewed: YES NO Business License # 5333 Applicant License # Business Information: Property Owner / Job Location Information: Name: 4(/ame:� 4° Street: /'-1 Street: / L( 7 // els cidey S City /Town: (,)e 1-4. °L C City/Town: rerc.c ,,* 4 0(0 6 0� Telephone: gi 3 - 7 —1 c(/ 6 Telephone: ce'(( cil -Sad / 27,V Photo I.D. required / Copy of Photo I.D. attached: YES jVNO - Staff Initial J -1 / M- 1- unrestricted license J -2 / M- 2- restricted to dwellings 3- stories or less and commercial up to 10,000 sq. ft. / 2- stories or less Residential: 1 -2 family v Multi- family Condo / Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. over 10,000 sq. ft. Number of Stories: Sheet metal work to a completed: New Work: V Renovation: HVAC Metal Watershed Roofing Kitchen Exhaust System Metal Chimney / Vents _ Air Balancing Provide detailed description of work to be done: 1 5 , / / ( rc Fees with Building Permit: $25.00 Residential, $50.00 Commercial. Fees for jobs without a Building Permit $6.00 per $1000 Minimum fees for jobs without Building Permit $50.00 Residential, $100.00 Commercial File # SM- 2012 -0029 APPLICANT /CONTACT PERSON AARON MORIN ADDRESS /PHONE 140 WEST ST (413) 247 -0550 () PROPERTY LOCATION 142 MAPLEWOOD TER MAP 23D PARCEL 159 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out / Fee Paid 0 Typeof Construction: NEW DUCTWORK & USE EXISTING FURNACE New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 533 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER : § Intermediate Project : Site Plan AND /OR Special Permit with Site Plan Major Project: Site Plan AND /OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management e/" gv• 4 1 1*//a -' Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of Planning & Development for more information. 142 MAPLEWOOD TER SM- 2012 -0029 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON 1GIS #: 3315 ac r ti Map 23D Block_ 159 t O � SHEETMETAL PERMIT • Lot. 001— , , � ° Permit: SHEETMETAL s r4,R 'Category: Permit # SM -2012 -0029 PERMISSION IS HEREBY GRANTED TO: Project # JS- 2012 - 000983 Est. Cost: $4,500.00 Contractor: License: Expires: Fee Charged: $25.00 AARON MORIN Sheetmetal - 533 10/28/2013 'Balance Due: $.00 Owner: NORTHRUP SARAH # of Fixtures: Applicant: AARON MORIN DigSafe # AT: 142 MAPLEWOOD TER iUseGroup ConstClass ISSUED ON: 30- Apr -2012 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: NEW DUCTWORK & USE EXISTING FURNACE THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fixtures: Floor: Type: # of Fixtures Floor: Type: # of Fixtures Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC- 2012- 005699 25- Apr -12 1320 $25.00 212 Main Street, Phone:(413) 587 -1240, Fax:(413) 587 -1272, Email :lhasbrouck @northamptonma.gov GeoTMS® 2012 Des Lauriers Municipal Solutions, Inc. • RHVAC - Residential & Light Commercial HVAC Loads Program dilk Elite Software Development, Inc. Webb Air : IMP 142 MAPLEWOOD TERRACE Woburn, MA D18G1 .. 0 3 12 Page 15 Room Load Summary Reports - System; #1 ..Room Load - , Htg Htg Run Run Clg Clg Clg Zone Clg Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh CFM Fact CFM CFM - - -Zone 1 - -- 1 /Living Room 168 7,748 102 2 -6 452 3,864 366 178 1.00 1 178 178 2 Open Dining 238 8,222 108 2 -5 485 2,879 385 132 1.00 s 132 , 132 3 . Bedroom 144 5,716 75 2 -5 463 2,747 310 126 1.25 158. ; 126 4 Kitchen 169 6,262 82 2-4 694 2,636 691 121 1.00 121 1 121 5 Entry 42 3,041 40 1-4 458 337 197 15 1.00 15 ' 15 6 Bath 42 1,964 26 1-4 461 875 84 40 1.25 50 ; ` 40 Zone 1 Subtotal 803 32,953 433 13,338 2,033 613 - ' --613 - - -Zone 2 - -- n 7 Bedroom 154 3,360 44 1 -5 568 1,686 206 77 1.00 77 77 8 Bedroom2 182 2,843 37 1 -6 473 2,022 206 93 1.00 ; 93 93 9 Master Bed 216 7,268 95 2 -6 535 4,573 479 210 1.25 1 263 210 And Bath 10 Hall 80 1,602 21 1-4 485 920 84 42 1.00 " -42- 42 Zone 2 Subtotal 632 15,073 198 9,201 975 423 475 423 System 1 Totals 1435 48,026 631 22,539 3,008 1,036 1,130 1,036 Main Trunk Size: 16x12 in. System #1 Cooling System.Surxwmary Cooling Sensible /Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 2.129 88 %/12% 22,539 3,008 25,547 Recommended: 2.439 77 %/23% 22,539 6,732 29,271 1 Monday, April 23, 2012 ' RHVAC . Residendataughtcommerciat H1/AC Loads Pragr n Elite Software Development, Inc. 142 MAPLEWOOD TERRACE Wobum;�AA 0fi 4 r Page 3 Miscellaneous Project Data . . Project File Name: MORIN -142 MAPLEWOOD System Input Data , Outdoor Outdoor Indoor Indoor Grains - -- System 1 - -- Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter: 0 N/A N/A 72 N/A Summer: 86 75.22 50% 75 51 External Overhangs No Projection Offset No Projection Offset 1 3 1 6 0 0 2 5 0 7 0 0 3 4 0.5 8 0 0 4 0 0 9 0 0 5 0 0 10 0 0 Duct Sizing tilppts Runouts Main Trunk Duct Material: Flexible Duct Galvanized Steel Roughness Factor: 0.010000 0.000300 Pressure Drop: 0.1000 In.wg /100 Ft. 0.1000 In.wg /100 Ft. Minimum Velocity: 450.0 Ft. /Minute 650.0 Ft. /Minute Maximum Velocity: 750.0 Ft. /Minute 900.0 Ft. /Minute Minimum Height: 0 Inches 0 Inches Maximum Height: 0 Inches 0 Inches Outside Air Data -- f , Winter Summer Infiltration: 0.900 AC /Hr 0.400 AC /Hr Volume of Conditioned Space: X 11480 Cu.Ft. X 11480 Cu.Ft. 10,332 Cu.Ft. /Hr 4,592 Cu.Ft. /Hr X 0.0167 X 0.0167 Total Building Infiltration: 172 CFM 77 CFM Total Building Ventilation: 0 CFM 0 CFM - -- System 1 - -- Infiltration & Ventilation Sensible Gain Multiplier: 11.97 = (1.10 X 0.989 X 11.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 34.08 = (0.68 X 0.989 X 50.68 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 78.32 = (1.10 X 0.989 X 72.00 Winter Temp. Difference) Monday, April 23, 2012 • ftHVAC - ltssidentiai it Light Commercial "mac Loads Programs Elite Software Development, Inc. Webb A�' - 142 MAPLEWOOD TERRACE WObum,: IVA 01801 04-23 -201 Page 2 Project Surrary . Project: 142 MAPLEWOOD TERRACE Company: ASM SHEETMETAL Client: Representative: Address: Address: City: City: Phone: Phone: Fax: Fax: II Comment: Design Data — Project Name: 142 MAPLEWOOD TERRACE Reference City: Westover AFB, Massachusetts Daily Temperature Range: Medium Latitude: 40 Degrees Elevation: 308 Feet Altitude Factor: 0.989 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter: 0 N/A N/A 72 N/A Summer: 86 75.22 50% 75 51 Check Figures Total Building Supply CFM: 1,036 CFM per square foot: 0.722 Square feet of room area: 1,435 Square feet per ton: 588.287 Buildirg'Load S - u, - . Total heating required with outside air: 48,026 Btuh 48.026 MBH Total sensible gain: 22,539 Btuh 88 Total latent gain: 3,008 Btuh 12 % Total cooling required with outside air: 25,547 Btuh 2.129 Tons (based on sensible + latent) 2.439 Tons (based on 77 % sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Monday, April 23, 2012 P3D _ e M 2 2012 142 MAPLEWOOD TERRACE HVAC LOAD ANALYSIS for a ' � k 4 � Prepared By: ASM SHEETMETAL i 04 -23 -2012