Loading...
06-064 (12) o Stamped certification from a Massachusetts registered engineer that the water system was constructed and tested in accordance with the approved plans. • Utility Ties - At least two swing ties to fixed and easily identifiable objects for: o Sewer wyes, cleanouts and stubs o Water gates, service boxes, corporations, directional and reduction fittings, tapping sleeves, etc. o Each location is to be clearly drawn on a separate sheet (need not be 4x6 cards). Please contact me if you have any questions or need more information. Thank you, David David Veleta, P.E. Department of Public Works 125 Locust Street Northampton, MA 01060 T: 413- 587 -1570 ext.4310 C: 413- 326 -0649 F: 413- 587 -1576 E: dveleta @no'r.odpw. orq W: www.northamptonma.gov /dpw 2 Louis Hasbrouck From: David Veleta [dveleta @nohodpw.org] Sent: Thursday, March 29, 2012 11:52 AM To: Carolyn Misch; Louis Hasbrouck Subject: Fwd: Beaver Brook Estates Carolyn and Louis - see below, fyi. David Original Message Subject:Beaver Brook Estates Date:Thu, 29 Mar 2012 11:47:06 -0400 From:David Veleta <dveletacu,;nohodpw.org> To:Patrick Melnik <patmelnik @2rnai1.com> CC:Mark Reed <mark(u;heritagesurveys.com >, Ned Huntley <nhunt1ey�r nohodpw.org>, Gene Tacy <genetacy(a)comcast.net> Dear Patrick, On February 1, 2012, the DPW received a transmittal of As -Built construction plans for Beaver Brook Estates. The transmittal consisted of a cover letter, three plan plan sheets prepared by Heritage Surveys, Inc. dated January 11, 2012, stamped and signed by Richard P. Weisse, P.E. and Bruce A. Coombs, P.L.S., and a CD with unsealed plan sheets in AutoCad and PDF formats. The DPW considers these to be a preliminary submission and will review them for accuracy and completeness when staff time allows. A request for revisions and /or clarifications may be required before the plans are finalized. DPW is aware that the existing 4 -unit condo has been connected to the new water and sewer utilities and that a trench permit for these utility connections was issued in the fall of 2010 for a new house on Lot #8. Typically, project closeout testing, certification and record information are required to be submitted before utility connections are allowed. The approval of the connection permits for the exiting 4 -unit condo was necessary to provide continuity, but the approval for Lot #8 was an oversight on the part of DPW. Prior to the issuance of any new utility connection trench permits, the following testing, certification and documentation are required for the completed project utilities. • Sewer System - All tests to be witnessed by the Engineer of Record or his/her field representative and results to be submitted to DPW for review and approval. o Mandrel (Go- No -Go) test o Video inspection with a copy of the DVD provided to the DPW o Vacuum or exfiltration testing of all manholes o Gravity system leakage testing (pressure or exfiltration). (If leakage testing is not feasible for sewer pipe runs that are already connected and in service, then only video and mandrel testing are required.) o Stamped certification from a Massachusetts registered engineer that the sewer system was constructed and tested in accordance with the approved plans. • Water System 1 Louis Hasbrouck From: David Veleta [dveleta @nohodpw.orgj Sent: Wednesday, April 18, 2012 8:02 AM To: Louis Hasbrouck Subject: Re: Beaver Brook Estates Louis - Working this out with Ned. Hope to have an answer for you by the end of this week. Thanks for your patience. David On 4/11/2012 3:31 PM, Louis Hasbrouck wrote: Dave, Are we OK to issue the certificate of occupancy for Beaver Brook Estates lot 8? Let me know one way or the other. Thanks. Louis Hasbrouck Building Commissioner City of Northampton Town of Williamsburg 212 Main Street Northampton, MA 01060 (413) 587 -1240 City of Northampton email messages are public records except when they fall under one of the specific statutory exemptions. i * The Commonwealth of Massachusetts r` ,,-: ja .• ) i e ° , City of Northampton` �- � - � � C rti icate of Occupancy f f In accordance with 780 CMR, Section 5120.0 The Eight Edition of the Massachusetts State Building Code for Single and Two Family Dwellings With the 2009 IECC Energy Code this Certificate of Occupancy is issued to the premise or structure or part thereof as herein identified. Identify Name of Building of Space Within Certificate No. Issued to Ed Jazab BP- 2011 -0458 Identify property address including street number, name, city or town and county Located at 28 Evergreen Street, 62 Chestnut Avenue Unit #8 Florence, Hampshire, Massachusetts Use Group Classification(s) Single Family `Residential (5B R3) This Certificate of Occupancy is hereby issued by the undersigned to certify that the premise, structure or portion thereof as herein specified has been inspected for general fire and life safety features. This certificate shall allow fox the use as herein described and in conformance with any and all conditions as identified below. It shall be posted in a conspicuous place within the space as directed by the undersigned. Failure to post the certificate, failure to comply with conditions or, tampering with the contents of the certificate is strictly prohibited. Conditions of Use Single Family Residential - Structural and Safety Systems Must Be Maintained Name of Municipal Date of Final Map /Plot: Buildin• Official Charles Miller Inspection 04/05/12 Signature of Municipal �/ D ate of f � Building Official i O6-O6n� Issuance 04/20/12 y 1 1