Loading...
24A-042 M - 85 Series Elevations 0 0 0 o � ® o o P � o 0 0 0 0 0 X 0 0 X 0 Single Vent Center Vent 12 10 0 0 0 O O 0 13 O 0 0 11 X 0 X Single Hung End Vent 14 14 16 18 16 O O 16 17 16 0 15 15 Fixed Two Lite Fixed Two Lite Fixed Picture Picture Picture Window Window Window WINDOW & DOOR CORPORATION 4. Type: Low -E, tinted, obscure, tempered, 3.02 Installation laminated, argon - filled and spandrel. A. Install windows using only skilled mechanics with experience in this trade, in accordance C. Fixed sash with manufacturer's recommendations and 1. The fixed lite shall be factory glazed with approved shop drawings. a marine (wrap- around) reusable vinyl B. Provide required support and securely glazing channel. fasten frames. Units shall be installed 2. Tint: clear or tinted (specify color) plumb, level and square without twist or 3. Type: Low -E, tinted, obscure, tempered, bow. laminated, argon - filled and spandrel. C. Provide thermal isolation where components 4. Coating: none /pyrolytic low E on #3 penetrate or disrupt building insulation. Pack surface. fibrous insulation in shim spaces at assembly D. Performance perimeter to maintain continuity of the thermal 1. Seal durability: conformance to ASTM E barrier. 774 -88; visible permanent IGCC D. A non - hardening sealant compatible with certification label for CBA rating level. aluminum shall be provided by the installer 2. Annealed glass lites: conformance to and applied in sufficient quantity at joints ASTM C 1036 -91 and intersections to provide a weathertight 3. Tempered glass lites: conformance to seal between the window and surrounding ASTM C 1048 -91 construction. Wipe off excess and leave exposed sealant surfaces clean and 2.05 Finish smooth. A. Application: on clean extrusions free from E. Remove and legally dispose of existing significant surface blemishes or scratches on windows and other materials generated by exposed surfaces visible when the installed the installation of the new windows. window's operating sash is closed. B. Coatings shall meet the requirements of 3.03 Field Testing AAMA 2603 -02 for Pigmented Organic A. Conduct on -site tests of installed units in Coating on Extruded Aluminum, AAMA 2604 - conformance with AAMA 502 -90 for air and 02 for High Performance Organic Coatings, water infiltration with representatives from AAMA 2605 -02 for Superior Performing the window manufacturer, contractor and Organic Coatings; and AAMA 611 -98 for owner or architect present. Anodized Architectural Aluminum. B. Select test units as directed by the owner's C. Color: Standard colors available are Bronze, or architect's representative. White, Sand -Beige and Hartford Green - C. Conduct tests with an AAMA- accredited electrostatically - applied baked -on polyester laboratory provided by the owner, architect meet or exceed AAMA 2603. White (70% or contractor. Kynar ), Bronze (70% Kynar ® ) - high - performance fluoropolymer meet or exceed 3.04 Adjusting and Cleaning AAMA 2605. Clear and Bronze Anodized A. Adjust frames, sash and hardware after (anodic coatings) meet or exceed AAMA 611. installation, as necessary, to ensure smooth D. Custom colors and finishes conforming to and watertight operation. AAMA 2603 -02, 2604 -02, 2605 -02 or 611 -98 B. Leave windows clean and free of labels and are available with required minimum order dirt. quantities. III. EXECUTION 3.01 Examination A. Verify that openings are within tolerance, plumb, level, clean, and provide a solid anchoring surface, and are in accordance with approved shop drawings. B. Correct defective openings as required before installation. Page 4 of 4 M -85 Specs — Rev. 6/08 -- WINDOW 6 DOOR CORPORATION 2.02 Materials 1. Fabricate and shop assemble frame and A. Aluminum Windows and Components sash members into complete windows 1. Aluminum shall be of proper alloy for under responsibility of one commercial window construction. All manufacturer. extruded sections shall be of 6063 -T5 2. No bolts, screws or fastenings to bridge aluminum alloy. thermal barriers or impair independent 2. Main frame and sash members shall be frame movement. a nominal thickness as required by 3. Fabricate to allow for thermal movement AAMA/WDMA/CSA 101/I.S.2/A440 -05. of materials when subjected to a Mainframe shall be 2.6875" in depth. temperature differential from —30 degrees F to +180degrees F. B. Hardware B. Frame: Mainframe shall be a mechanically 1. Locks shall consist of a cam latch at the .joined construction. Corner joints should be interlocking meeting rail. "seam sealed" with a quality grade of 2. Balances (single and double hung): sealant meeting the requirements of AAMA Sash will be balanced by block -and- 803.3. The sash shall be assembled with tackle type sash balances attached to two screws at each corner. All screws at the main frame by pivot sash shoes of joints of sash and mainframe shall be nylon. Balances shall hold the sash secured into integral screw ports. stationary in any position along the full C. Sash: tubular horizontal sash rails coped range of sash travel. Balances shall and fastened to vertical sash stiles with a meet the requirements of AAMA 902.2. telescopic- design joint secured with one 3. Rollers (horizontal sliding): Operable stainless steel screw per sash corner; sash will be supported by two steel ball- corners factory- sealed with sealant bearing rollers mounted in each of two conforming to AAMA 800 -92. polycarbonate wheel housings per sash. D. Sash design: Hung windows: Lift rail on C. Thermal Break bottom sash interior; mechanical meeting 1. Main frames and sash members are to rail interlock; weep holes for drainage. be extruded aluminum with a structural Sliding windows: Continuous extruded pull thermal barrier of high- density low rail on operable sash interior; mechanical thermal conductivity polyurethane, meeting rail interlock; weep holes for poured and debridged. drainage D. Weatherstripping 1. Shall be 250 polypile with mylar fins 2.04 Glass and Glazing Materials conforming to AAMA 701.2, A. Construction Specification for pile weatherstrip. 1. Insulating glass units shall be 3/4" overall Weatherstripping shall be doubled at all thickness (1" for fixed windows) with two points of contact of the sash and main panes of SS, DS, or 3/16" glass, frames and at the interlocking meeting separated by an air space for insulation. rail. Air space: aluminum spacer with corner E. Screens keys and desiccant. Perimeter sealant: 1. Screen frame shall be of hollow polyurethane. aluminum extrusions. Finish shall 2. All insulating glass units shall meet the match the main frames and sash. requirements of the ASTM E 774 2. Insect screening shall be fiberglass or specification, Class A. aluminum wire secured with a vinyl B. Operable sash spline. 1. Glass in the operable sash shall be 3. Screens for single -hung and horizontal factory glazed with a marine (wrap - sliding windows shall be half length around) reusable vinyl glazing channel. (operable sash only). Screens for 2. The operable sash shall be equipped for double -hung windows shall be full side take -out (hung units) or vertical length. take -out (sliding units) for cleaning and is removable from the inside for ease of 2.03 Fabrication maintenance. A. General 3. Tint: clear or tinted (specify color) Page 3 of 4 M -85 Specs — Rev. 6/08 A f, • WINDOW 8 DOOR CORPORATION C. Configuration: single hung /double hung; C. Furnish written documentation that the horizontal sliding- single vent/end vent/center windows for the project conform to vent; fixed. AAMA/WDMA/CSA 101 /1.S.2/A440 -05. D. Glazing: Factory-glazed with '/" insulating D. Furnish visible, permanent IGCC glass (1" insulating glass in fixed units). certification labels for the CBA rating level on double insulating glass units. 1.07 Performance Requirements A. Conformance to HS -C30, HS -C35, HS -050 E. Manufacturer's warranties (Horizontal Slider); H -C35, H -C40, H -050 1. Windows: warrant for one year against 52x81 (Single Hung); F -HC50 (Fixed) defects in material or workmanship specifications in AAMANVDMA/CSA under normal use. 101/I.S.2/A440 -05 when tests are performed 2. Sealed insulated glass (IGU): warrant on the minimum test size set forth therein. seal for ten years against obstruction of B. Thermal testing per AAMA 1502.7 -81 at the vision resulting from failure of the prescribed 4'0" X 6'0" test size. hermetic seal, excluding that caused by (Manufacturer to provide test results on breakage or abuse. Warrant units request). containing muntin bars and/or capillary C. Sound: testing per ASTM E 90 -90 with '/." tubes for three years, and laminated insulating glass. (Manufacturer to provide glass for five years. test results on request). 3. Limited warranty on aluminum finishes D. Forced Entry Resistance: Shall meet the to meet AAMA specifications. (AAMA requirements for AAMA 1302.5 -76 and 2605 - 15 year limited, and AAMA 2604 ASTM F588 Load Identification Level 30. - 10 year limited) warrant against chipping, peeling cracking, blistering, 1.08 Submittals fading or chalking. (AAMA 2603 - 5 A. Shop Drawings: The window manufacturer year limited) warrant against chipping, shall submit elevations, floor plans or peeling, cracking or blistering. window location chart; typical window elevations; full size details of composite 1.10 Delivery, Storage and Handling members, hardware and components not in A. Handle windows and accessories in manufacturer's data; glazing details for accordance with AAMA CW -10. factory- glazed units, and complete B. Protect the windows from the elements, anchorage and installation details for the construction activities and other hazards architect's approval. until project completion. B. Product data: manufacturer's specifications, test reports from an AAMA- accredited II. PRODUCTS: laboratory, and standard details verifying conformance with specifications. 2.01 Acceptable Window Manufacturers C. Samples: one sample of specified finish for aluminum and other samples as requested A. Windows shall be the "M85 Series" as by the architect. manufactured by Wojan Window and Door Corporation, Charlevoix, Michigan. The 1.09 Quality Assurance "M85 Series" is a (single hung consisting of A. Submit for pre -bid qualification approval ten an operable lower sash and a fixed upper days prior to the bid opening: lite, double hung consisting of operable 1. One sample window representing the upper and lower sash, single -vent horizontal window being bid with color being the sliding with one operable and one fixed only exception. sash, end vent with two operable sash and 2. Valid test reports from an AAMA one fixed center lite, center vent with one accredited laboratory- confirming operable center sash and two fixed end lites, fixed picture) with thermally improved conformance to Paragraph 1.07 test confos. frame and sash. The specifications and materials for the "M85 Series" are as B. Submit bids based only on pre - qualified follows: "equal" as confirmed in a pre -bid written addendum. Page 2 of 4 M -85 Specs — Rev. 6/08 At A WINDOW 8 DOOR CORPORATION M -85 Series Specifications (Section 08520) I. GENERAL: 6. AAMA 611 -98, 'Voluntary Specification 1.01 Scope of Work for Anodized Architectural Aluminum." A. Furnish all necessary materials, labor, and 7. AAMA 701 -92, "Voluntary Specification equipment for the complete installation of for Pile Weatherstripping" 8. aluminum windows for this project as shown AAMA 800 -92, 'Voluntary Specifications and Test Methods for Sealants" on the drawings and herein specified. 9. AAMA 902.9, 'Voluntary Specifications for Sash Balances" 1.02 Products Furnished but not Installed under this 10. AAMA 1502.7 -81, "Voluntary Test Method Section — for Condensation Resistance of Windows, List products, which are only supplied under this Doors and Glazed Wall Sections" section, but may be installed "by others" or "by 11. AAMA CW -10 -, "Care and Handling of owner." (Examples: extra sets of glazed sash, Architectural Aluminum from Shop to Site" extra screens, position lock, etc.). B. ASTM — American Society for Testing and Materials 1.03 Products Installed but not Furnished under this 1. ASTM C 1036 -91, "Standard Specification Section — for Flat Glass" List products that are to be installed under this 2. ASTM C 1048 -91, "Standard Specification section, but may be supplied "by others" or "by for Heat - Treated Flat Glass" owner" (Examples: HVAC louvers, A/C units, 3. ASTM E 90-90, "Standard Test Method etc.). for Laboratory Measurement of Airborne Sound Transmission Loss of Building 1.04 Related Sections Partitions" A. Section 07190 — Vapor and Air Barriers 4. ASTM E 283 -91, "Standard Test Method B. Section 07900 — Sealants for Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors" 1.05 References 5. ASTM E 330 -90, "Standard Test Method A. AAMA — American Architectural for Structural Performance of Exterior Manufacturers Association Windows, Curtain Walls and Doors by 1. AAMANVDMA/CSA 101/I.S.2/A440 -05, Uniform Static Air Pressure Difference" "Standards /Specification for windows, 6. ASTM E 331 -86, "Standard Test Method doors, and unit skylights ". for Water Penetration of Exterior 2. AAMA 502 -90, "Voluntary Specification Windows, Curtain Walls and Doors by for Field Testing of Windows and Sliding Uniform Static Air Pressure Difference" Glass Doors" 7. ASTM E 547 -86, "Standard Test Method 3. AAMA 2603 -02, 'Voluntary Specification, for Water Penetration of Exterior Performance Requirements and Test Windows, Curtain Walls and Doors by Procedures for Pigmented Organic Cyclic Static Air Pressure Differential" Coatings on Aluminum Extrusions and 8. ASTM E 774 -88, "Specification for Sealed Panels." Insulating Glass Units" 4. AAMA 2604 -02, "Voluntary Specification, Performance Requirements and Test 1.06 System description Procedures for High Performance A. AAMA designation: M -85: HS -C30, HS -C35, Organic Coatings on Aluminum HS -050 (Horizontal Slider); H -C35, H -C40, H- Extrusions and Panels." C50 52x81 (Single Hung); F -HC50 (Fixed). 5. AAMA 2605 -02, "Voluntary Specification, B. Windows: 2.6875" frame depth; extruded Performance Requirements and Test aluminum with integral structural polyurethane Procedures for Superior Performing thermal break in frame and sash members; Organic Coatings on Aluminum integral nailing fin (equal -leg frame optional); Extrusions and Panels." finish factory- applied; frames and sash factory- assembled. Page 1 of 4 M -85 Specs — Rev. 6/08 f . iF , A+, rK t1 Y , t Today's Aluminum Windows The Smart Choice for Long - lasting Beauty and Efficiency central insulating core (thermal barrier) between interior and exterior frame and sash members make modern aluminum windows a head -to -head competitor with wood or vinyl for energy efficiency and coidensation resistance. In addition, aluminum windows offer long -term durability, stability and freedom from structural deterioration. S trength and rigidity. Unlike wood, aluminum cannot absorb oisture, so there is no swelling, shrinking, warping, cracking or rotting. Unlike vinyl, luminum will not become brittle at low temperatures or pliable at high temperature. Aluminum is 23.2 times more rigid than vinyl and 7.2 times more rigid than soft wod, so it's much less likely to bend or twist due to building settling or from expansion nd contraction caused by temperature extremes. Unaffected by weather and tim , aluminum windows maintain their integrity against air and water leakage, while staying easy to open and close, for many years. Verified by independent laboratory II testing, Wojan aluminum windows and ? ' - doors routinely exceed national performance standards set by the American Architectural Manufacturers , ti Association. D urable and attractive in appearance , , , - with modern baked on enamel finishes, 1 ? : & r t M ,, L �'° L �>> aluminum windows are available in �` �� ' F • d ' � �� ' e A virtuall any color and add beauty for ° . • � �' .. " 4 t t-i " Y Y Y ; , 'i years to come. , ''gTAZ'.'-:.„-:: ''. - ;r: 0 0) :, 4 r ' 104:40340&:* :p1416•411G-ANy , ' t ,, - w + )',Y,-..,- , . . "" ? ' ,nr -, F es . . cgi • C Ota ,. f 3 11 25rd re gtur e nitents K ALUMI�N It's here to stay L - a1:'SYa: 0 Energy- efficient 3/4 -inch insulating glass (1" in fixed window) - Low -E or tinted glazing also available for maximum thermal performance •® Polyurethane thermal barrier in frame and sash t s © Highly efficient fin seal weather - stripping 0 — 5 •L 11 x Commercial grade extrusion offer s trength with a 0 ? .: 0-7-=.-: tea^ t sa ' .r .-,r S� yk ,� :ai .: solid, attractive appearance .1 "" , 5 • vt .i .i'kY .7�L .'_-- 1 . r -Iftig - - - 1 - - - , . :,.,, © ' ' ,;F Cope (non- mitered) corners resist flexing and a ; r ,• , ti . . . •` ,, ` stop racking damaging to water ensure structural leakage. integrity, reduce air infiltration and a; ,11! 8 O Glazed inserts with marine-type wra around glazing -;: ` f3 • P 9 9 --��, • system for easy field replacement of glass compared 6 _�..... _ s:' = , , Y to direct -set glazing i m ,, ' a : i':1 i - 0 Ball- bearing easy -glide rollers provide smooth, quiet ; �, ; .. "` g� .;..':.7::'1 ,. 2 .' operation of sliding windows. '. ,„ , x , ;` `l 1 E ' ft� rt EY E r E z - ! r ?' 4 a y : 4 . 4 r r f �1ri a a ..,;i ,: g r i , y E Spt � N p (I idEEi • i - : ,f d „R,L ., d -EJ, c ..s y ./, 4 .. { i S.J •::., :E�4i le ,ry3,'3 P #. Y , - .r }1 k ,,����� A ii Ee e 4 � 7' f { ;1.r� x J � 1 0 i k .''r">"" - ae " s Block &tackle balances, readily accessible �f ;: � ' y 31 r � j , } : through side take-outs, offer positive, safe operation E i f - u f x �f y r, „ .,yT,i. 13 of hung windows and greater reliability compared to E ` ' i `} q4. •z' t f �” i lii , R ,%, *41 torsion springs. `� _ . _ , " ' '� K # ® 41 c S `J , �i a to J ' 12 € . - , . i n =f Heavy die cast aluminum hardware with positive E p , 1 P. .,;:;,--t•: _ E, f v —_— a cam - action latch enhances E r – � E t , ", " 4 security. E H i r r , :,k � R . /iii ' al'� x .. , --'1,s • 'T-7,5; . ` ' " r ® Durable, low- maintenance electrostatically - applied • baked -on enamel finish �` `' x .. 2 3 „, , ® Integral nailing fins or finless configuration offers easy, flexible installation. O Spring - loaded screens install and remove easily. Side take -out sash for easy cleaning Iy ' jj t • � � Energy - efficient 1 - inch insulating glass - Low - E or tinted glazing also available for maximum thermal performance. `' • I. 7 t- t s..;'.. .,..,:..: _ -..,,, ,.. ..... .. - .,. 6::S 3.a s. •n sa.n •.,.. -. {:. xrtime :", '• ., ...ir ,.....»,,,,Irv.+3aatM.k :e' .4,„...,„,. t::.i5. ss`av,,,,, The M...85 S erie s The Cost - effective Choice for New Construction and Renovation -;34 _ ice,,., -1' •'� - " G "' ,... / ; J, - l-0 Fr, � _- )1 1- N ' . M 7 - 1.]hhui .. ,is^ .ice 1 ..,.. &.'k.1'�.xs>`..i:� . *.^° .-. *~' " a i'''f " � rl�y 1�1;`n � ,1 q ; ."� p ,,, = ,rte— __ Ilt1 1 II ° lit I fil 1 '1 - ._ i 1 _ 77, ft -T �� � q •' ' ti; �- e 9 !d �'• ?' � _ il{ I 4 t 0 �h 3,, Ig { _ m 1! I �i� �I {i , ' u� Custom Appeal, x + Custom Service, _ _ , :.. Maximum Value S ince 1952, Wojan products have been bringing comfortable environments to multi - family housing, hotels, homes, offices and classrooms. Whatever the performance requirement, for residential or commercial new construction or remodeling, Wojan provides economical window and door products while offering the design flexibility of special styles, shapes, sizes and custom colors. . " ' z' P.O, Box 95 - 217 Stover Road - , : , + . ,r % x ' 4 c Charlevoix, MI 49720 -" WINDOW & DOOR ---. Phone: (231) 547-2931 " ' CORPORATION 1 (800) 632 -9827 Fax (231) 547-4237 PPG Industries Performance Glass Calculator Calculated Center -af Mass Thermal and Optical Properties Based on NFRC 100.2001 Environmental Design Conditions Detaile tarOoehle Glaaitlp as Specified cameo/ Glass Um i "(3ntm)Ct(w Gee Cesny Dicenslan 112- (13n n) Gee Fill AK Indoor Glace yle va* (amen) Sakaban 40 on Clear (Surface 403) , Caihufctical Than: at end Optical Prepen as h smiting coefficient 0.53 SoIaeHeat Caahr Coefficient 0A8 U Yaiues {tic aJueO) Metric Metric to8llsh (Kcaltbeteft :) Mole) (pTlSfhrAt� winter 14gtsiima 1.45 1.611 0,34 summer Daytime 155 149 0.28 Relative Heat Gain Metste &a/thrive') meals (KW) E696ers tSTWlxle) 296 344 106 LSO (Light to Solar Gam+Ratio) 148 Tranaartkaanco (94) ' Visibia 72 tktrawioketi Ktoe'hman Darner) We hle 21/33 Total Solar E fter9y 95 Reflectance (1$) mate (OJL) 14 Visible (Iri) 11 idol Solar Energy (Out) 37 GWQrPrsprrp*s L' a` it Tra lrl[I13;sCe 88.04 .4.1 1.97 R.e'te ranee 4220 -2.60 128 While PPG kteliieWts this calculated peTforrr1anCe data to be reasonably accurate, it may not precisely agree with similar performance data calculated using tha LEL Window 5.2 program. PPG% published data is based on die LBL Window 9.2 program. u I ,, , 4 t 4v a n r r "� �rr;a 7,1ri 8� �ti ; i n t a w ")r . x t rr $- �, i x . L , r ,.' aG j V+kp it+n -Y R! w v pia :. ' i fs to '^ �r��' T'�a`' s�� T g �7? .. 1 � � '` u"1r ' a ' v"' i s ' . C r r r' IS t. ' m ' . 'r ... I 'i'' � . y t p 7 � qY 4 1 s` �3 x t..wlx e � a`� ff�. `� qt}� N, k. ' r3 s r.. n � th' ° $` l ,,.4.4r0)175" r h' . + r I jlist V.1. "ar t z x J 4 , rot hek5 nccdtj! r °',Wits i t r �[ 7 '; : '' : sit " , zd va x .ax �� "�"F.`k %.`�L�o i .a"'� 7!'� C , �fw'�a y � ���.�, 4; F, t� � «�z a.��tV{5,� "n � ,..n . bb kvka �t .�.'n ' 8. - z t d N,v v ):. � -S , . r, t PPG Industry) lieedtluartera • One PPG Pita Pittsburgh, PA 15272 USA I tM2001-2048 PPG tnaustrles . AO Rights Reserved 1161i'alRehire 44 Priyary . r. p dl t i n,. w+ni+n � r M1).1 ' drfnt.t0 E l8 'OW fghtll7.eportl.asp s INdZ.:/ l l 0z 'trl in(' \ 1 IMPORTANT If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). DISCLAIMER This Certificate of Insurance does not constitute a contract between the issuing insurer(s), authorized representative or producer, and the certificate holder, nor does it affirmatively or negatively amend, extend or alter the coverage afforded by the policies listed thereon. ACORD 25 (2009/01) ACORD CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) TM 01/19/2011 PRODUCER 860.482.5591 FAX 860.496.9713 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION Burns, Brooks & McNeil ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR www.burnsbrooksmcneil.com ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. 69 Water Street P.O. Box 717 Torrington, CT 06790 INSURERS AFFORDING COVERAGE NAIC # INSURED 385 Central Glass & Mirror Inc. INSURERA: Peerless Insurance Company 24198 DBA New England Glass & Mirror Co., Inc INSURERS: Excelsior Insurance Co. 11045 31 Connecticut Avenue INSURERC: The Netherlands Insurance Co. 24171 Norwich, CT 06360 INSURER D: INSURER E: COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADD'L TYPE OF INSURANCE POLICY NUMBER POLICY EFFECTIVE POLICY EXPIRATION LIMITS LTR INSRC DATE (MM /DD/YYYY) DATE (MM /DD/YYYY) GENERALLIABILITY CBP8567494 01/01/2011 01/01/2012 EACHOCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY PREM SES Ea occurrence) $ 100,000 CLAIMS MADE X OCCUR MED EXP (Any one person) $ 5,000 A PERSONAL & ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP /OP AGG $ 1,000,000 — 1 POLICY TO JECT fl LOC AUTOMOBILE LIABILITY BA8829778 01/01/2011 01/01/2012 COMBINED SINGLE LIMIT X ANY AUTO (Ea accident) $ 1,000,000 ALL OWNED AUTOS BODILY INJURY B SCHEDULED AUTOS (Per person) HIRED AUTOS BODILY INJURY NON-OWNED AUTOS (Per accident) $ PROPERTY DAMAGE (Per accident) GARAGE LIABILITY AUTO ONLY - EA ACCIDENT $ ANY AUTO OTHER THAN EA ACC $ AUTO ONLY: AGG $ EXCESS / UMBRELLA LIABILITY CU9505453 01/01/2011 01/01/2012 EACHOCCURRENCE $ 10, 000, 000 X OCCUR CLAIMS MADE AGGREGATE $ 10,000,000 A $ DEDUCTIBLE $ X RETENTION $ 10,000 $ WORKERS COMPENSATION WC9549793 01/01/2011 01/01/2012 X ToRrunnl�TS ER AND EMPLOYERS' LIABILITY C ANYI EMBER EXCLUDED? /EXECUTIVE Y I ! N Y E.L. EACH ACCIDENT $ 1,000,000 (Mandatory In NH) E.L. DISEASE - EA EMPLOYEE $ 1,000,000 If yes, describe under SPECIAL PROVISIONS below E.L. DISEASE - POLICY LIMIT $ 1,000,000 OTHER DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES / EXCLUSIONS ADDED BY ENDORSEMENT / SPECIAL PROVISIONS Re: Northampton. ConEdison Solutions and the Property Owner are included as an additional insured if required by Nritten contract or agreement, subject to the terms and conditions of the insurance policy. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 10 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL Consolidated Edison Solutions, Inc. IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR 100 Summit Lake Drive, Ste 410 REPRESENTATIVES. Valhalla, NY 10595 AUTHORIZED REPRESENTATIVE Patricia Tedesco, CIC ACORD 25 (2009101) ©1988 -2009 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD The Commonwealth 'of Massachusetts �- Department of Industrial Accidents rli 47,1 Office of Investigations I i � = 600 Washington Street s Boston, MA 02111 www,mass.gov /ilia Workers' Compensation Insurance Affidavit: Builders/ Contractors /Electricians /Plumbers Applicant Information Please Print Letribly Name (B usiness /Organization /Individual): Nife ,b/Or 4 6 qS5 Address: f J j irxe -7 --4 L City /State /Zip: r, /Z#t,f,J7 r i C c 3t Phone ft: ' f'7 /c d Are you an employer? Cheek the appropriate box: Type of project (required): 1.54 I am a employer with /6 4. 0 i am a general contractor and 1 employees (full and /or part-time).* have hired the sub-contractors 6 • ❑ New construction listed on the attached sheet. 7. El Remodeling 2. ❑ I am a sale proprietor or partner- ship and have no employees 'these sub- contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. 171 Building addition [No workers' comp. insurance comp. insurance.+ required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.0 1 am a homeowner doing all work officers have exercised their 11. 0 Plumbing repairs or additions ' myself. [No workers' comp. right of exemption per MGL y ] p 12.0 Roof repairs insurance required.] t c. 152, § 1(4), and we have no employees. [No workers' 13.0 Other comp. insurance required.] *Any applicant that checks box di must also fill out the section below shooing them workers' compensation policy information. t I tomeowners who submit this affidavit indicating they are doing all work and therl hire outside contractors must submit a new affidavit indicating such. iContractors that check this box must attached an additional sheet shoving the namo of the sub- contractors and state whether or not those entities have employees. It'the sub - contractors have employees, they must provide their workers' comp. policy number. I am an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: 0 l.^,EI.` `XJtr - Policy # or Self -ins. Lie. #: J 7 9 Expiration 1///20 2. �1 } � E x tration Taate: / Job Site Address: (5 / 5% r City/ State / Zip: /U O.i"t 14 C..)/C)C'D Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and /or one -year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify' and he pains I p s of perjury that the infornurtion provided above is true and correct. Signature: ('" r- ' y Date: . .23 . rJ /,1� e Phone #: 5T are '' 167j Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit /License # Issuing Authority (circle one): 1. Board of Health 2. Building Department 3. City /Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone #: 1 tic OPERATING :` =r � FIXED t SILL ( r SILL 2 1/2' 2 1/2' !_ i Mit i i��_ • :,:f -{ ] 7/I6' r— - 3/16', I - _...�_ I 1' 7/16' ]. --{ 1 3/16'1 ry _...i .... I j H , M. ■;< ;, v 1 7/16' r....i 2 11/16' I t'_ }_ / /I_ f ` L v t i„..J J r - � .I t 3/16 i 11 r 1 -----2 1/8"---j 1 - 2 3 / 4 "- - ----I 1-1 1 / 2' 1' 1 -----SCREEN © OPERATING JAMB ® MEETING STILES 0 FIXED JAMB 1 I - 3 1 /B' H © MEETING STILE H-32-1 I- 48 H F 76 j F 70 H ► 1 74 74 106 - 106 1 1 1 " A B C D Notes: US NEW ENGLAND GLASS 8 MIRROR CO. xsaarma. 0 71im. *187 -1019 Ntaidi.CT06360 0 Fat mamma - Window to be Wojan Series M85 Single Hung. Notlhamplon - Finish to be Standard White Painted. Window Replacement - Glass to be insulated with low E coating, tempered safety. kthlect -1 Sill flashing to match window frame GC: ConEdisca Solutions - Window type A is 1st floor office area, quantity 12 BurIngton, MA - Window type B is 1st and 2nd floor, quantity 76 Jackson Skeet School Window Elevations - Window type C is in the Library , quantity 8 ors: Scale: Pepe: - Window type D is in the Stairwell, quantity 2 05112111 His 1 of t I , Versionl .7 Commercial Building Permit May 15. 2000 SECTION 10- STRUCTURAL PEER REVIEW (780 CMR 110.11) 1 Independent Structural Engineering Structural Peer Review Required Yes Ca No 0 SECTION 11 - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT David Pomerantz I . as Owner of the subject property here authorize Torn Haling of New England Glass to act o , 1. • :If.' .. matter relative to work authorized by this building permit application. AWL ()IAN Signal lc ()WA Date I Tom Malin of NL % I n gland Glass as Owner /Authorized Now Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Toni Haling of New England Glass Print Name Signature of Owner /A. - Date SECTION 12 - CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: Not Applicable d Name of License Holder : _ License Number Address Expiration Dale Signature Telephone SECTION 13 - WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes 0 No 0 • Version1.7 Commercial Building Permit May 15. 2000 SECTION 9- PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES - FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116 (CONTAINING MORE THAN 35,000 C.F. OF ENCLOSED SPACE) 9.1 Registered Architect: Robert 1 laveies Not Applicable ❑ Name (Registrant): — 8039 3 Converse Street Registration Number s >'j I,. yt ter, S H I. - 08/31/2011 S. Haveles ActertS H !ec Ex iration Date Lut.. LI1 (413) 283 -2553 p Da.! ]J 1107 2307 ?49 ..' lQ Signature Telephone — 9.2 Registered Professional Engineer(s): Name Area of Responsibility 38130 Address - Registration Number 06/30/2012 Signature Telephone Expiration Date Name - Area of Responsibility Address Registration Number Signature Telephone - Expiration Date Name - Area of Responsibility Address - Registration Number Signature Telephone - Expiration Date Name Area of Responsibility Address - Registration Number Signature Telephone Expiration Date 9.3 General Contractor New England Glass Not Applicable ❑ Company Name: Tim I laling Responsible In Charge of Construction 31 Connecticut Ave Norwich CT 06360 Address 410 (860) 887 -1640 S ignature Telephone Version1.7 Commercial Building Permit May 15, 2000 8. NORTHAMPTON ZONING Existing Proposed Required by Zonin •Ibis column to be tilled in by Building Dcpartmcnt Lot Sue Frontage Setbacks Front Side L R: L: R: Rear Building I )eight Bldg. Square Footage Open Space Footage — ° o ( Lot area minty bldg & pared parking.) of Parking Spaces Fill: IN ohmic t I.o,atir 1) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO 0 DON'T KNOW Q YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO Q DONT KNOW Q YES Q IF YES: enter Book Page and/or Document #t B. Does the site contain a brook, body of water or wetlands? NO Q DON'T KNOW Q YES Q IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Q Obtained Q , Date Issued: C. Do any signs exist on the property? YES Q NO (2) IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES O NO Q IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO Q IF YES, then a Northampton Storm Water Management Permit from the DPW is required. Version I.7 Commercial Building Permit May 15. 2000 SECTION 4- CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations ❑ Existing Wall Signs ❑ Demolition ❑ Repairs ❑ Additions ❑ Accessory Building ❑ Exterior Alteration ❑ Existing Ground Sign ❑ New Signs ❑ Roofing ❑ Change of Use ❑ Other ❑ Brief Description Remove existing windows and install new energy efficient ones. Of Proposed Work: SECTION 5 - USE GROUP AND CONSTRUCTION TYPE USE GROUP (Check as applicable) CONSTRUCTION TYPE A Assembly ❑ A -1 ❑ A -2 D A -3 0 1A � ❑ A -4 ❑ A -5 ❑ 1B ❑ B Business ❑ — 2A 0 E Educational ❑ 2B ❑ F Factory ❑ F-1 ❑ F-2 ❑ 2C ❑ H Hi9h Hazard ❑ 3A ❑ I Institutional ❑ I-1 p 1 -2 ❑ 1 -3 ❑ 3B ❑ M Mercantile ❑ 4 ❑ _ R Residential ❑ R -1 ❑ R -2 ❑ R -3 ❑ 5A ❑ S Storage ❑ S -1 0 S -2 ❑ 5B ❑ U Utility ❑ Specify: M Mixed Use ❑ Specify: S Special Use ❑ Specify. COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS, ADDITIONS AND /OR CHANGE IN USE Existing Use Group: Proposed Use Group: Existing Hazard Index 780 CMR 34) Proposed Hazard Index 780 CMR 34): SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor (sf) 15 , 1 St 2 °d 2nd 3rd 3rd 4 t" 4 15 Total Area (sf) Total Proposed New Construction (sf) Total Height (ft) Total Height ft 7. Water Supply (M.G.L. c. 40, § 54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System: Public ❑ Private 0 Zone Outside Flood Zone❑ Municipal ❑ On site disposal system❑ Version 1.7 Commercial f3uildint Permit May 15, 2000 Department use only City of Northampton Status of Permit: Building Department Curb Cut/Driveway Permit 212 Main Street Sewer /Septic Availability Room 100 Water/Well Availability Northampton, MA 01060 Two Sets of Structural Plans phone 413 -587 -1240 Fax 413 -587 -1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT, REPAIR, RENOVATE, CHANGE THE USE OR OCCUPANCY OF, OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE INFORMATION 1 1.1 Property Address: This section to be completed by office Jackson Street School Map Lot Unit 120 Jackson Sired Zone Overlay District Northampton, MA 0 1060 Elm St. District CB District SECTION 2 - PROPERTY OWNERSHIPIAUTHORIZED AGENT 2.1 Owner of Record: City of Northampton 210 Main Street, Northampton MA Name (Print) Current Mailing Address: (413) 587 -1261) Signature _ _ Telephone 2.2 Authorized A! ent: David 'omcrantz 240 Main Street Northampton MA Name (Print) Current Mailing Address: (413) 587 -1260 Signature Telephone SECTION 3 TED + ' TRUCTION COSTS Item l Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building S131,000.00 (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of Construction from (6) 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total - (1 + 2 + 3 + 4 + 5) Check Number This Section For Official Use Only Building Permit Number Date ( — 1 Issued Ulf / Signature: 7/ il Building Commissioner /Inspector of Buildings Date 120 JACKSON ST BP- 2012 -0071 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 24A - 042 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: windows replaced BUILDING PERMIT Permit # BP- 2012 -0071 Project # JS- 2012- 000108 Est. Cost: $131000.00 Fee: PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: NEW ENGLAND GLASS & MIRROR CO INC Lot Size(sq. ft.): 278784.00 Owner: NORTHAMPTON CITY OF JACKSON STREET SCHOOL Zoning: URB(100)/ Applicant: NEW ENGLAND GLASS & MIRROR CO INC AT: 120 JACKSON ST Applicant Address: Phone: Insurance: 385 CENTRAL AVE Norwich CT06360 ISSUED ON:7/20/2011 0:00:00 TO PERFORM THE FOLLOWING WORK: Replace Windows POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 7/20/2011 0:00:00 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner