06-064 (4) 27. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note: ThruLoks are engineered for post attachment supporting a railing. 28. Smoke and CO detectors as required. 780 CMR R314 and R315. 29. Closets beneath stair which have doors must be drywalled with %2 ". 780 CMR R302.7 Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. My email address is: cmiller(cnorthamptonma.gov Thank you +r your cooperation on these matters. . 'Z huck Miller City of Northampton Assistant Commissioner and Zoning Enforcement 14. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape. 780 CMR R310 b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft at 1 floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 3/4" from the top of the threshold and only in- swinging doors. 780 CMR R311.3 15. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ", maximum riser 83/4", maximum overall variance for the run is 3/8 ", 4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception, 4 3/8" on balustrade, 6" in the triangle. Graspable rail 1 %" minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 16. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36 ", 4" sphere rule. 780 CMR R312.1. 17. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In interior non - bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1%2" 16ga. strap must extend a minimum of 6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom. Notches are different. 18. Dryer duct transition is limited to 8' of aluminum flex and must be exposed. 780 CMR M1502.4.3 19. Dryer duct maximum equivalent length is 25' or per manufacturer's specs. 780 CMR M1502.4.4.1, no screwed connections. 20. Markup air is required for any exhaust hood of 400 CFM or more. 780 CMR M1503.4 21. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5' from the duct outlet for all fireplaces 22. Fire and draft stopping shall be completed before rough inspection. 780 CMR R302. 23. Ignition barriers in place before final. 780 CMR R316. 24. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA and 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. Energy information including mechanical equipment posted on the electric panel. d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Building Option Package. 25. Vapor retarders. Although these are still in the code there are exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer (diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99% of the moisture in a structure. This is evident every time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 26. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. City of Northampton °' , r, Massachusetts ) -- w A DEPARTMENT OF BUILDING INSPECTIONS , „ + - ' ” 212 Main Street • Municipal Building ' r Z °' Northampton, MA 01060 h- INSPECTOR Matt Murphy March 20, 2012 329 Southampton Road Westhampton, MA 01027 Subject Location: 126 Emerson Drive unit #11 Map Block: 06 -064 Mr. Murphy, These are some additional items that are needed: 1. Truss, LVL and I -joist engineering 2. Thermal Bypass Checklist, Initial HERS and final HERS ratings, Energy and equipment info posted on the electric panel. 3. Heat loss calculations, room by room with equipment sizing 4. Final electronic or hard copy plan showing field changes. Footings, foundation, beams, ECT. As of August 4 2011 the 8 Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8 Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I soils (table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. 5. Ceiling joist are intended to prevent spread, once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8 -16nd common are required at each connection. 780 CMR R802.3.1. 6. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1 /3rd 780 CMR R802.3.1 7. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 8. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and number of jack studs required. 9. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss 10. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 11. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basements, 6'4" at beams /ducts. 780 CMR R305.1. MA amended 12. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4 13. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. Order restrictors. 780 CMR R612.2 MUNICIPAL SEWER/ AVAILABILITY APPLICATION Northampton Streets Department 125 Locust Street Northampton, MA 01060 587 -1570 A Department of Public Works Trench Permit and Sewer Entry Permit shall be required prior to any construction or connection activity associated with this application. Location: 28 Evergreen Road, Beaver Brook Estates, Lot 11 Inquiry Made By: Joseph Wayne 413 - 575 -2586 Date of Inquiry: 2/21/12 Reason for Hook into City Water & Sewer Request: Municipal Sewer Main in Front of Location: Yes No Municipal Storm Drain Available: 5'/2 deep Yes yL No Size of Sewer Main: ' Material: ' v C , Age: Depth of Sewer Main: Size of Service Connection: Type of Service Connection: Tie -in to Sanitary Main Tie -in to Sanitary Stub Comments: t v , j Note: If this availibility is for new construction, this form must be hand delivered to Building Inspector. A corresponding "sewer entrance fee" shall be paid prior to making any connection to the municipal sewer system. Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department specifications. 7/Q John Hall Sewer Department cc: Ned Huntley, Director DPW / j Louis Hasbrouck, Building Commissioner / a 7 s r 9 1► • MUNICIPAL WATER AVAILABILITY APPLICATION Northampton Water Department 237 Prospect St. Northampton, MA 01060 587 -1097 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: 28 Evergreen Road, Beaver Brook Estates, Lot 11 Inquiry Made By: Joseph Wayne 413 -575 -2586 Date of Inquiry: 2/21/12 Number of Type of Single Family X Type of Condo X Units: 1 Unit(s): Accessory Apart. Ownership: Rental Multi- family (Annlicant to fill out the above) Municipal Water Main in Existing service to Front of Location? Yes: X No site? Yes: X No Size of Water Main: 8" Material: Ductile Iron Age: 2006 Approximate Static Street Flow Test Conducted: Yes: No: X Pressure: 40 If done attach results Size of Service Connection 1" Suggested Meter Size: 3/4" Comments: The Water Department cannot guarantee adequate water pressure during peak demand times at elevations above 320 feet. • A corresponding water entranc- - - • all be paid prior to making any connection to the municipal water em. • Arrang: ents of ch n• talla ' • i hall b made with the Northampton Water Department with a minimum of 5 -orki da not' ication. • ` Al £rk . 11 o f to No ,.ms o a Department specifications. David W. Sparks, Superintendent of Water Entry $200.00 Meter Radio $150.00 $Radio Read $100.00 cc: Ned Huntley, Director cc: Louis Hasbrouck, Building Commissioner Note: If this availability is for a new construction, it must be hand delivered to the Building Inspector. :rn;) I tdii1 :11 of cr .Apphcatiotl`.G ", aic,.' ; i' !1 itl S i'ti' doc � 1 e .SItA ij.7 . o . $ -� l g �'I, ;... !■— ` ems= ? _ c_7---a• DEPARTMENT OF BUILDING INSPECTIONS • _° 212 Main Street 0 - Municipal Building ,INSPECTOR `, - Northampton, ALA • 01060 ' ~ wf ri • LOCATION - _SQUARE FOOTAGE AMOUNT BASEMENT @ .20 • P 39 5 -- 1 FLOOR @ .50 / 5 3 / 2 FLR @.3o • �� 7 5 3 b FLOORS, F.INIISIT ATTIC, GARAGE @ .20 ■57rY //// r C - DECK/PORCI ES @ :20 - /: 5 A ir-z) • TOTA L.. �-+ /) / 3) . cif) • • • The Commonwealth of Massachusetts -.. Department of Industrial Accidents ... Office of Investigations . 600 Washington Street b ; 14 7411 Boston, MA 02111 t www.mass.gov /dia Workers' Compensation Insurance Affidavit: Builders / Contractors /Electricians /Plumbers Applicant Information / Please Print Legibly Name (Business /Organization/Individual): / ( - , /, f/ f _(e_c !' ®.ice_ _ ____ Address: *3 -- j 5O v 7 1 . ra(i g1: City /State /Zip: /: � Phone #: . `" 3 / V , / - 5 . Are you an employer? Check the appropriate box: Type of project (required): 1. El I am a employer with 4 ❑ I am a general contractor and I 6. New construction employees (full and/or part- time). * have hired the sub contractors — 2. am a sole proprietor or partner- These sub-contractors listed on the attached sheet. 7. [ Remodeling Thbt have ship and have no employees 8. [ Demolition working for me in any capacity. employees and have workers' 9. n Building addition [No workers' comp. insurance comp. insurance.$ required.] 5. n We are a corporation and its 10.n Electrical repairs or additions officers have exercised their 11.❑ Plumbing repairs or addinons 3. ❑ I am a homeowner doing all work myself. [No workers' comp. right of exemption per MGL 12.1 I Roof repairs insurance required.] t c. 152, § 1(4), and we have no employees. [No workers' 13.! Other comp. insurance required.] *Any applicant that checks box #1 must also fill out the section below showing their workers' compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such, *Contractors that check this box must attached an additional sheet showing the name of the sub - contractors and state whether or not those entities have employees. If the sub-contractors have employees, they must provide their workers' comp. policy number. Iam an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site .information. Insurance Company Name: Policy # or Self -ins. Lic. #: Expiration Date: - Job Site Address: City/State /Zip: Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one -year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify nder the pains and penalties ofperjury that the information provided above is true and correct. tgnature: Date: G9" r / ;?-- Phone #: 57'.- 7r7 -- - - - - - -- - - - -- - -- Official use only. Do not write - this-area, to be completed by city or town official City or Town: Permit /License # Issuing Authority (circle one): 1. Board of Health 2. Building Department 3. City /Town Clerk 4. Electrical Inspector 5: Plumbing Inspector 6. Other Contact Person: Phone #: i $-tw7`iert SEGTIO{,a" y �?OIty& ad�r'�tµY' R. CZFw o v{ f k k� ��,A"4 Nt�B CONRUCTION U�SE t w x � k V'm,!v�ir?F'HS � "'�; ^ �'��..f. 315 � `.�d�+ tr , d• �hb,^r'�+k _,. V .a, �' �v" d - .�- p 8.1 Licensed Construction Supervisor: � Not Applicable ❑ /' ! Name of License Holder: n1/ /( /9" t y ' . 9 /6 License Number - 302 �4 i ef M R / / Address Expiration Date Signature /I' phone 9I . Re is ere - . ome mprbuemen ton ractor< "Ati i" "' : , tx;a t. ; ,,. k w`" } : v a}v, Not Applicable ❑ Company Name Registration Numb v A / , 5�v4 � 41 0 ` 7/3 Address Expiration Dat 7 Off /t / b Telephone v75J_5/7"/S•_ e" t�k�s�`",u o f .°� A .��; ?�'��t"�Za•'b'�C'+nv'�� �^�1 ° F -. *� a ax t1 � r 4�'.� 1 �y`nt t � g y y a. SEC IQN OieRF$K - V 'C:; MpEN g)9:N INSU, ANCE AFFIDAVIT1(NI G L 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes ❑ No ❑ pp �� On The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -year period shall not be considered a homeowner Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature a � { 'E�w t kP�' '} t7 } �`�° �'�.`t, - 7'41 is'h�` i '��k'xi5t i � ":�� J w t .� ? ;, °r�7 � .sM1a^'r'�''S ?S'v""�' �. irii5`ir..c.a i.M4ytl1 Yd 't' „(x� i.. SECTION 5R DESCRIPTI ®N 1 O' PROPOSED WORK c heck all"a. :licable)4 y �m r,�p .d � `M � 34 st tL a' k 1 u t " ky ,'' 1`i +v �k r irK #°'i �` r.�' kb+ w ';. �` xz �,, 'r,x * yr'' §.;�i . i ,, ' ,yts. M `i s s„� � rc 3 ,. . ' rk''GdW'�,�' r4. '-p y ��.'r`an ' r"ka,. - .�, > New House Addition U Replacement Windows Alteration(s) n Roofing L___ Or Doors D Accessory Bldg. ❑ Demolition F F New Signs [D] Decy [C] Siding [D] Other [D] ,7 4 i� t , i 50../(A'5,0 Brief Description of Proposed io ,, o� Work: A• 1 Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll - Sheet S ''If ;t , , o. s •r n.® or :a ddttict o.:eztstit g4hous.irag,3ieompl #e . ,6 follow= nci a. Use of building : One Family V Two Family Other rr�� b. Number of rooms in each family unit:_ Number of Bathrooms 2. c. Is there a garage attached? Cle d. Proposed Square footage of new construction. ?,5 2 Dimensions t 'x 59 1 e. Number of stories? s , f. Method of heating? Ole- - t Fir e places or Woodstoves Number of each l' g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of constructionQ i1i. P &I i. Is construction within 100 ft. of wetlands? Yes 1 No. Is construction within 100 yr. floodplain Yes ✓ No t j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations'? 7- Yes No . I. Septic Tank City Sewer 7 Private well City water Supply f/ 11SE I N PAIRRfZATIf MA TO �BE CPNI ETED WHEW t ' eni QWENk2 t R etiaTR'ACTOR APPLIE „ F, OR SI ILbING PERMIT,�,� ` I. V J e ' ay//e. , as Owner of the subject property /� hereby authorize A >I T L/ i-p it y to act o my be alf, in all matters relative to work authcirized by this building permit application. Sign of O X 46 Owner 7 Date I, , as Owner /Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signe.d_.under the pains and penalties of perjury. Print Name Signature of Owner /Agent Date . a Section 4. ZONING Alt Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information b Existing Proposed Required by'ioning This column to be filled in by Building Department [ it35 _� Lot Size ___J _R —_ TT 0 Frontage S 3__.._.s — '!._____ __ ____I__� =.._ Setbacks Front ! _____ 1 , Side L "i R:. L: I R:r Rear L �_' Building Height ____{'I 1 ( Bldg Square Footage - Open Space Footage % _ (Lot area minus bldg & paved I 3Z72 !.......—j L I { I parking) # of Parking Spaces 1 �._ Fill: i--1To �,._ �_.. �.. .._.___.__....__..._,__._.__... (volume &Location) r V I I — A. Has a Special Permit /Variance /Finding ever been issued for/ the site? NO Q DON'T KNOW 0 YES IF YES, date issued:] I IF YES: Was the permit recorded at the Registry of Deeds? NO Q DONT KNOW Q YES IF YES: enter Book F-7 ` Pagel 3 1 and /or Document #' `O f 7 , I 5 B. Does the site contain a brook, body of water or wetlands? NO gr DON'T KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained Q , Date Issued: C. Do any signs exist on the property? YES Q NO a IF YES, describe size, type and location: - - ' D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, exc ation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES Q NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. (��` \ r r City of Northampton 5 �Er � i � t Building Department , . : Ott r � p - ' w i4y -� ¢ °' 441 0. ' / 1/. 01 .. 212 Main Street , F b , ;�; I ,,, q , 4 Room 100 a' "�a� orthampton, MA 01060 �I ® ,m � w p , �4 -4 g � , e ���� N > ` . "one 413- 587 -1240 Fax 413-587-1272 a ; � � ', , �' � ; z I ,, !},' XL - ."6 '' ak F ,w�Y:� "", t�.„,«w, -s .. �4 t`r. APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SEC�IQf�` .IN e FOR MAIdt T -� t s *h, '1 , r'This secti on to b e I c om pleted 3 b ,officesa 1.1 Pro a Address: v ' ? y� x ` �' y r x .SIB � JO � /� f '� • xik , Yrk y ' 'l"4' i� y ! ,. , � hl i tga x wF z V, ' y _ ,yf. 4 � ' 3k . J' i ! .6 �"' i y Si "Zo ' ' m 4 5 y k%� r `VZ dverlay District' $ ,'� + '?�? ','v r`a'h S 4 �N'Y. 'VV y K ,iii k ta7 M 3` w ' r 4 , r 4 p �,.. 'o-;� � � k �r .�,,3 3 'L U r � y 1 i • �.. ,. k. k''a. �}c 4YY£M j4� ; ...iii t . ... ` f . � ' EImS�' ct�. 'r � +? * .. �rw. s.�.: CB r , w';5f a r s . f d ' a 4'•, " a ' ' , s�' ,. C ,; : d VV x: S n r 'V -$W m y , -4. a v x {: : c....�, . , ... ....... ..... . V SE CTION'2''V'PROF?ER{T ( W .NE R SHIP /AUTi ORIZE IAGENT ga Y ;g "" sa, .. , g* „.n`. ” `�h ; r 2.1 Owner of Record: josep 14-t G ' f ir i Name Print) Current Mailing Address: ,X • . .. ' ��:e + (' .�" Telephone//[[ r ,, ^ "� ca Sig.. ure �^"! !' (� $ 2.2 Authorized Agent: Name (Print Current Mailing Address: Via — ...2 37 _% S ff3 '_ , r/ V Signature Telephone #. , ?a r 'Atti i.*1.43 :10"i ...*P i k ti s ' .mss,.* "SECTION 3 . ESTIMATE CONSTRUC COSTS {{4 Item Estimated Cost (Dollars) to be 1 Offi cial • Use.Only completed bypermit applicant ..'• '' '- 1. Building ( y (a) Buil P e rr i i t Fee' h 1 2. Electrical ( b) E ti sm ate d 'Totai Cost ofh3:, I ea. 00 a ;ileConstri ction from (6) 4,.x t44. r 3. Plumbing Building Permit F Y 4. Mechanical (HVAC) G7 � . i : r 1 p v "� ' ' ,,8 ,, ,,. ��yy�yypp x ! k ¢ e 5. Fire Protection '1', 00 w e 4 . 4 4 , 414°.° , 1 , N , , ,, , rt 3 r = 6 Total = (1 + 2 3 + 4 + 5) r+b.� CheckY Number s E > . r �C l v l �� Th i s Section Fo r Official Use Only r 1 :4:i4 ' 4 : - . 4 4 4757:1 .!;4`,...d:' 4 ;; .1 .7 .7 ,/ t ,. ) � t '7 h I 1 7 {� 4 Lt x D ate Building : PerrT u f' l um be r � t F y *4, ''ti `tom , �.t w I ss uetl x.' .+ .eLaF n , x^w' 1 r�"w z�� c � r ,? h, i s ,, h''¢(, y eaY•4:i4� a , ki t+" Yt 'YAr .,, +,- �``"� d I t S 1 t..n F do #+,'''r- kAV K s , r"k h, : h , i gna t ure, 4 , � t n w t x y,i, rr 4',,dv to r� w uti i4"" at's' rra,fw Building Commissioner /Inspector of Buildings „. Date , s s opr OK— fci) E v t 0A) File # BP- 2012 -0749 APPLICANT /CONTACT PERSON MATT MURPHY I") Yc 16 1 ? . f ADDRESS/PHONE 329 SOUTHAMPTON RD WESTHAMPTON (413) 237 -4415 O ' `= rov Ai‘ 1A PROPERTY LOCATION UNIT 11 - 62 CHESTNUT AVE EXT - 28 EVERGREEN RD _ 4!)_ MAP 06 PARCEL 064 001 ZONE URA THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out 6 9 301 9e Fee Paid ��/ Typeof Construction: CONSTRUCT 2 STORY SFH W /ATT GARAGE /DECK/PORCH New Construction Non Structural interior renovations Addition to Existing_ Accessory Structure Building Plans Included: Owner/ Statement or License 066916 3 sets of Plans / Plot Plan THE OLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON ORMATION PRESENTED: Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management Si . ` re of Building 0 icial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. UNIT 11 - 62 CHESTNUT AVE EXT - 28 EVERGREEN RD BP- 2012 -0749 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 06 - 064 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: New Single Family House BUILDING PERMIT Permit # BP- 2012 -0749 Project # JS- 2012- 001323 Est. Cost: $258800.00 Fee: $1932.90 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: MATT MURPHY 066916 Lot Size(sq. ft.): Owner: WAYNE JOSEPH M & LINDA L Zoning: URA Applicant: MATT MURPHY AT: UNIT 11 - 62 CHESTNUT AVE EXT - 28 EVERGREEN RD Applicant Address: Phone: Insurance: 329 SOUTHAMPTON RD (413) 237 -4415 () WESTHAMPTONMA01027 ISSUED ON:3/22/2012 0:00:00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT 2 STORY SFH W /ATT GARAGE /DECK/PORCH POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 3/22/2012 0:00:00 $1932.90 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner