Loading...
38A-065 (7) 12. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. See 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 13. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basement without habitable space, 6'4" at beams /ducts. 780 CMR R305.1. 14. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. See 780 CMR R308.4 15. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. See 780 CMR R612.2 16. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ", maximum riser 8 % ", maximum overall variance for the run is 3/8 ", 4" sphere rule on risers, 4 3/8" on balustrade, 6" in the triangle. Graspable rail 1 minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 17. Gaurds 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36 ", 4" sphere rule. See 780 CMR R312.1. 18. Educate the plumber and electrician about maximum notch and hole sizes and placement. See 780 CMR R502.8 and R602.6. In studs hole not lager than 40% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1 1/4" 16ga. strap must extend a minimum of 6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom. Notches are different. 19. Fire and draft stopping shall be completed before rough inspection. See 780 CMR R302. 20. Ignition barriers in place before final. See 780 CMR R316. 21. Energy aspects shall comply with the stretch energy code. See 780 CMR Appendix 115AA and 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. Energy information including mechanical equipment posted on the electric panel. d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Building Option Package. 22. Deck ledgers and post must be appropriately attached. Note: TimberLoks are not engineered for rail post attachment. See 780 CMR R502.2.2.1 Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. My email address is: cmiller(a�northamptonma.gov Thank you for your cooperation in this matter. Chuc it City of Northampton City of Northampton Massachusetts e 4 { p DEPARTMENT OF BUILDING INSPECTIONS � ' 212 Main Street • Municipal Building ,; Northampton, MA 01060 :P d'iy '6 \ � s INSPECTOR Richard Ruth 15 Maple Street Turners Falls, MA 01376 August 5, 2011 Subject Location: 188 Earle Street Map Block: 38A -065 Mr. Ruth As of August 4 2011 the 8th Addition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic as well as some specific requirements related to your project. This is not a substitute for purchasing and reading the MA codes. Specific Issues: 1. Unit separation walls shall be 1 hour walls and shall be continuous to the exterior sheathing. See 780 CMR R302.3. 2. Smoke and CO detectors as required. A smoke in every bedroom, a CO /smoke within 10' of every bedroom door, a CO /smoke at the bottom of every floor leading to another finished floor, a CO /smoke on each level, a CO /smoke for each 1200 sqft or part thereof. See 780 CMR R314 and R315. 3. The thermal envelope must be complete, insulation shall be enclosed within, and substantially in contact with an air barrier, the hatch shall be insulated and gasketed, all shall meet the requirements of the 2009 IECC. 4. Landing can't be tapered unless one door is fixed shut. Egress and emergency escape requirements shall be strictly met. a. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft at 1 floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 b. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 c. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 3/4" from the top of the threshold and only in- swinging doors. 780 CMR R311.3 5. Structures shall conform to 780 CMR 8 addition 1 and 2 family building codes with MA amendments. 6. Grading plan for structures being constructed required. See 780 CMR R401.3 for drainage requirements. 7. Where ceiling joist are not directly connected to the rafters, rafter ties are required. See 780 CMR R802.3.1. Minimum 2x4 16" OC nailed per 780 CMR Table R802.5.1(9) 4" slope 8 -16nd common at each connection. 8. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1/3' 1 780 CMR R802.3.1 9. Ridge boards must be the full depth of the cut 780 CMR R802.3. 10. A complete window and header schedule is required. See 780 CMR Table R502.5 for header sizing and number of jack studs required. 11. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss Door 3: Solid 21 0.350 7 Floor 1: All -Wood Joist/Truss:Over Unconditioned Space 758 31.0 0.0 24 Compliance ', : tem-nt: • •posed building design described here is consistent with the building plans, specifications, and other calculation- • ' ' ed ' . ►- permit application. The propo : • uilding h been designed eet - 2009 IECC requirements in RESche. - '. 4.4. d •mp with the mandatory •rre r ents ed i e RESc ec Ins i. hecklist. 1 /1 f‘ 65 • / a' e - T itle ' ' Signature Date Project Title: Yourga/Parker Report date: 07/28/11 Data filename: C: \Documents and Settings\beth \My Documents\REScheck\parker IV.rck Page 2 of 2 • CI REScheck Software Version 4.4.1 Compliance Certificate Project Title: Yourga /Parker Energy Code: 2009 1ECC Location: Northampton, Massachusetts Construction Type: Single Family Project Type: Addition /Alteration Heating Degree Days: 6404 Climate Zone: 5 Construction Site; Owner /Agent: Designer /Contractor: 188 Earle Street Jonathan Yourga/ Pauline Parker Richard R. Ruth Northampton, MA 01060 188 Earle Street 15 Maple Street Northampton, MA 01060 Tumers Falls, MA 01376 413 -824 -7346 angelas.hammer@yahoo.com Compliance: Passes Compliance: 10.7% Better Than Code Maximum UA: 272 Your UA: 243 The % Better or Worse Than Code index reflects how close to compliance the house is based on code trade-off rules. ft DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Gross Cavity Cont. Glazing UA Assembly Area or R -Value R -Value or Door Perimeter U- Factor Ceiling 1: Flat Ceiling or Scissor Truss 758 38.0 0.0 23 Wall 1: Wood Frame, 16" o.c. 410 26.0 0.0 21 Wall 2: Wood Frame, 16" o.c. 650 26.0 0.0 34 Wall 3: Wood Frame, 16" o.c. 90 26.0 0.0 5 Wall 4: Wood Frame, 16" o.c. 530 26.0 0.0 • 5 Window: Pella: Vinyl Frame, Triple Pane with Low -E 14 0.240 3 Window: Pella: Vinyl Frame, Triple Pane with Low -E 14 0.240 3 Window: Pella: Vinyl Frame, Triple Pane with Low -E 14 0.240 3 Window: Pella: Vinyl Frame, Triple Pane with Low -E 14 0.240 3 Window: Pella: Vinyl Frame, Triple Pane with Low -E 14 0.240 3 Window: Pella: Vinyl Frame, Triple Pane with Low -E 14 0.240 3 Window: Pella bath: Vinyl Frame, Triple Pane with Low -E 9 0.240 2 Window: Pella bath: Vinyl Frame:Triple Pane with Low -E 9 0.240 2 Window: Pella: Vinyl Frame:Double Pane with Low -E 14 0.300 4 Window: Pella: Vinyl Frame:Double Pane with Low -E 14 0.300 4 Window: Pella: Vinyl Frame:Double Pane with Low -E 14 0.300 4 Window: Pella: Vinyl Frame:Double Pane with Low -E 14 0.300 4 Window: Pella: Vinyl Frame:Double Pane with Low -E 14 0.300 4 Window: Pella: Vinyl Frame:Double Pane with Low -E 14 0.300 4 Window: Pella: Vinyl Frame:Double Pane with Low -E 14 0.300 4 Window: Pella: Vinyl Frame:Double Pane with Low-E 13 0.300 4 Window: Pella: Vinyl Frame:Double Pane with Low -E 13 0.300 4 Window: Pella: Wood Frame:Double Pane with Low-E 25 0.300 8 Window: Pella: Wood Frame:Double Pane with Low -E 25 0.300 8 Window: Pella copy 1: Wood Frame:Double Pane with Low -E 25 0.300 8 Window: Pella copy 2: Wood Frame:Double Pane with Low-E 18 0.300 5 Window: Pella copy 3: Vinyl Frame:Double Pane with Low -E 18 0.300 5 Window: Pella copy 4: Vinyl Frame:Double Pane with Low -E 13 0.300 4 Door 1: Glass 41 0.500 21 Door 2: Solid 21 0.350 7 Project Title: Yourga /Parker Report date: 07/28/11 Data filename: C: \Documents and Settings \beth\My Documents \REScheck\parker IV.rck Page 1 of 2 s: rtimf„. i . grit of Nortilantritan .1. --4.74 a. .igassarVirsttts • , c...0 ..e..,-.2--,- \--' ---11.1. ...p . , -,.— DEPARTMENT OF BUILDING INSPECTIONS k ...) 212 Main Street * Mimicipal Building .... --- ..., INSPECTOR ,. Northampton, MA 01060 .........-- A A LOCATION IVO C.,)./PC-1...t (Sriede 7 . - • ' . SQUARE FOOTAGE AMOUNT - BASEMENT ® 20 • 1 @ .50 • 3 cq. • • 2ND FLR @ lib . . . 4 FLOORS, FINISH ATTIC, GARAGE @ .20 DECK/F'ORCRES @ :20 . 6/ L2 TOT ... • . . • . . . . - • Hearing No.: ZBA - 2010 - 0032 Date: June 16, 2010 APPLICATION TYPE: SUBMISSION DATE: Residential Finding 5/10/2010 Applicant's Name: Owner's Name: NAME: NAME: YOURGA JONATHAN & PAULINE PARKER YOURGA JONATHAN & PAULINE PARKER ADDRESS: ADDRESS: 188 EARLE ST 188 EARLE ST TOWN: STATE: ZIP CODE: TOWN: STATE: ZIP CODE: NORTHAMPTON MA 01060 NORTHAMPTON MA 01060 PHONE NO.: FAX NO.: PHONE NO.: FAX NO.: (413) 584 -3027 0 (413) 584 -3027 0 EMAIL ADDRESS: EMAIL ADDRESS: Site Information: Surveyor's Name: STREET NO.: SITE ZONING: I COMPANY NAME: 188 EARLE ST SI(97) /URC(3)/ TOWN: ACTION TAKEN: ADDRESS: NORTHAMPTON MA 01060 Grant MAP: BLOCK: LOT: I MAP DATE: SECTION OF BYLAW: 38A 065 001 I Chpt 350- 9.3: Pre - existing Nonconforming TOWN: STATE: ZIP CODE: Book: Page: Structures or Uses May be Changed, 1484 672 Extended or Altered. PHONE NO.: FAX NO.: EMAIL ADDRESS: NATURE OF PROPOSED WORK: ZPA - ADDITION & ACCESSORY APT HARDSHIP: CONDITION OF APPROVAL: • FINDINGS: The designated Zoning Administrator granted the Finding based on the materials and graphics submitted with the application. The Findings of the Board Administrator under Section 9.3 for the addition of an accessory apartment as part of a single family house related to the pre- existing non - conforming residential use in an Si district. 1. The Administrator found that the change would not be substantially more detrimental to the neighborhood than the existing nonconforming use The property abuts residential uses and is the only lot in the SI district on that portion of Earle Street. 2. The Administrator found that the home would not extend any closer to any front, side, or rear property boundary than the current zoning allows and that the pre - existing structure already extends. 3. The Administrator also determined that the new construction would not create any new violation of other zoning provisions; and does not involve a sign. COULD NOT DEROGATE BECAUSE: FILING DEADLINE: MAILING DATE: HEARING CONTINUED DATE: DECISION DRAFT BY: APPEAL DATE: 5/11/2010 6/5/2010 6/24/2010 REFERRALS IN DATE: HEARING DEADLINE DATE: HEARING CLOSE DATE: FINAL SIGNING BY: APPEAL DEADLINE: 5/29/2010 7/14/2010 6/10/2010 6/24/2010 7/16/2010 FIRST ADVERTISING DATE: HEARING DATE: VOTING DATE: DECISION DATE: 5/27/2010 6/10/2010 6/10/2010 6/16/2010 SECOND ADVERTISING DATE: HEARING TIME: VOTING DEADLINE: DECISION DEADLINE: 6/3/2010 1 4:00 PM 9/8/2010 9/8/2010 MEMBERS PRESENT: VOTE: Malcolm B.E. Smith votes to Grant MOTION MADE BY: SECONDED BY: VOTE COUNT: DECISION: Malcolm B.E. Smith 1 Approved MINUTES OF MEETING: Available in the Office of Planning & Development. GeoTMS® 2010 Des Lauriers Municipal Solutions, Inc. J HOME OWNER EXEMPTION ACKNOWLEDGEMENT The State of Massachusetts allows the homeowner the right under 780CMR 108.3.4 to act as his/her construction supervisor. The state defines "Homeowner" as, " Person(s) who owns a parcel on which he/she resides or intends to be, a one or two family dwelling, attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two -year period shall not be considered a home owner." The building department for the City of Northampton wants person(s) who seek to use the home owner exemption, act as their own constriction supervisor, to be aware that by doing so you become responsible for compliance with state building codes and regulations. The inspection process requires that the building department be called to inspect work at various stages, which include foundation /footings (before backfill), sonotube holes (before pour), a rough building inspection (before work is concealed), insulation inspection (if required) and a final building inspection. The building department requires these inspections before the work is concealed, failure to secure these inspections can result in failure to obtain a certificate of occupancy until the work can be inspected. If the homeowner hires other trades to perform. work (electrical, plumbing & gas) the homeowner will be responsible to make sure that the trades hired secure their proper ermits in conjunction to the building permit issued, and that they get their required inspections. Failure of the individual trades to secure the permits and inspections as required can DELAY the project until such time as the proper permits and inspections are made I, understand the above. (Home owner /resident's signature requesting exemption) I will call to schedule all required building inspections necessary for the building permit issued to Date Address of work location .,, , . . • The Commonwealth of Massachusetts Department ofIndustrial ACcidents . ,... Office of InVestigation:s' 600 Washington Street . Boston, MA 02111 - . www.mass.gov/dia , •:,,,:' • ,.. -Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information - i, Please Print Legibly Name (BusinesS/Organiiation/Indivichino: ( 1 . , - - Address: i 5 ,/v1pt 9 ,.. • City/State/Zip: 1 , , y 4 ji . 1 Phone.#: ii 5 Are you an employer? Check the appropriatebox: • •Type Of project (required): , 1. E] I am a employer with 4. p I am a general contractor and I 6. 0 New coristraCtion have hired the sub-contractors oyees (fall and/or part-time).* listed on the•attached sheet. 7. 0 •• Ulla: -. ° 2. I ani a Sole pi or partner- ship and have no employees These sub-contractors have. .8. 0 D .....lidon • r_miloyec.s andhave workers' : . , - -....— -- . • working for me in any capacity. 9 :ie t;' tiEding a&litieki [No workep" comp-. insurance • 10.0 Electrical repairs or additions , • . 5. 0 We are a corporation and its 3 0 I am a homeowner dciing ill work officers baVeCcereise4 their - 11.0 Plumbing repairs or acklitiOns • . . I myself [No workers' comp. right of exemption per MGL 12E Roof repairs . • insurance required.] t • c. 152, § 1(4), and We have nci • einployees: [No workers' 13-n- Other 1 - . • . • . C911113 insurance reqUired.j. Any applicant Mat checks box ik roust also fill out the section below showing theirWorkers compensation policy information. ' '':: • t Homeownera who subtnit this affidivitimgdatini they are doing all work and then hire outside conttaCtora must submit anew affidavit indicating such. :contractors that rbi•e this box must attached an adtStional sheet showing the name of the sub-contractors and snit e whether-or nottbose-entities have ' • employees. 'lithe sub-contraCtorsbaVe employeeS, they must provide their wciikeis corop policy number. • .1 am an employer that isproviding workers' compensation insurance for my employees Below is tlze policy and job site information . . Insurance Company Name: - • . • . Policy # or Self-ins. Lic. # . Expiration Date . . Job Site Address: . : • .• City/Siale/Zip:' - . . - • - . Attach a copy of the workers' compensation, poliey declaration page (showing the policy number and_expiration date). . . . , Failure to secure coverage aS reqUired Ira Senti6ii.'25A 152 can lead to the iPciiiii"nri Of niinxiiril Penalties of a fine up to S1,500.00 and/or one-year impris' onmenc' as well as civil Penalties m the form of a STOP wolgco.pDER. anda fine of up to S250.00 a day against the yiolatOr. Be advised 'that a copy of thi.'s statement may be forwarded to ilie-Okfine - -Effii i iiii-i;ii - s --- oftii - t, '# o - t -- ,",7; . 6iiiiiiiW - - .:- -- ' .---' 777 _ I i l c i h e r e b y c e r t i n u , .. , ' p . . , d pen ," s o l p e r j u r y t h a t the inforntationprovideilabove and correct ' .,.. Sienature: ife - . Date: . • - , Phone #: , .-1, -- ,,, - __ . , _ _ ; . ' • . • • 9 r.' • . - • . . - Official use only. Do not write in this area, Id be completed by city or toWn'officiaL I . , . . • City or Town: '• Permit/License Lsuing Authority (circle one): .1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other . F- . . . . II I Contact Person: Phone #: SECTION 8 - CONSTRUCTION SERVICES 8.1 Licensed Construction S pervisor: ( / Not Applica ❑ Name of License Holder : A ( ( K w) /' ( / h 7 7 76 2- License Number / �ad a ! j / Addres Expiration Date Si. 'ature T: ephone 9. Registered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number Address Expiration Date Telephone SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the buildin ermit. Signed Affidavit Attached Yes No ❑ 11. - Home Owner Exemption The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he/she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two - year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) New House ❑ Addition Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [p Siding ID] Other 101 Brief Description of Prop d 5 k l o � �4 f 1 Oil jf Work: � � Q�l.>fe � > .�.� G��GI�K" Alteration of existing b droom Yel No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll - Sheet 6a. If New house and or addition to existing housin complete the following: a. Use of building : One Family T Family Other b. Number of rooms in each family unit: Number of Bathrooms 3 c. Is there a garage attached? / 1 / � i}( l d. Proposed Square footage of new construction. Zf G0 Dimensions �t/ (0 /` 3 7 e. Number of stories? f. Method of heating? 9iT 5 Fireplaces or Woodstoves W./1 Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? W � ,/ h. Type of construction i. Is construction within 100 ft. of wetlands? Yes ..../lo. Is construction within 100 yr. floodplain Yes No t ( j. Depth of basement or cellar floor below finished grade 6 f k. Will building conform to the Building and Z ning regulations? Yes No,"" I. Septic Tank City Sewer f, Private well City water Supply t SECTION 7a - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT JO / */1C i (/o 'A.. �'° LI � 4/,- /�i / i , as Owner of the subject property J ij/ hereby authorize A ( f-t -.t(,) P' to act on my behalf, in all matters relative to walk au • :. - • d b this application. .j , ature of Ow.. j�`! / Date I LC ( , /Q_ '� as Owner /Authorized Agent hereby declare that the statements and informa on on the fo?egoing application are true and acc - ate, to the best of my knowledge and belief. Signed under the pains and penalties of p- 'ury. il V . , A.) Ld , , ,- Print Name , 4. /'LIB tr Signature . 1" ner gent / Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size G ► Z5Q" S Frontage 100 1 Setbacks Front 20 t I I Side L:56 R:3J L: R: Rear la i Building Height 1 i � Q . Bldg. Square Footage % '' jam; Open Space Footage % (Lot area minus bldg & paved parking) # of Parking Spaces 6 Fill: (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /o a site? NO 0 DONT KNOW 0 YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW ® YES 0 IF YES: enter Book , 4 g Page (c, i Z and /or Document # B. Does the site contain a brook, body of water or wetlands? NO �ONT KNOW ® YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained ® Obtained , Date Issued: C. Do any signs exist on the property? YES 0 NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO V IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, ex ation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. 1 -..". 1 , i , lel 4 0 SOli ', i 1.- .4 Department use only RE EIVED City of Northampton Status of Permit: Building Department Curb Cut/Driveway Permit 2 q 2.011 212 Main Street Sewer /Septic Availability Room 100 Water/Well Availability Northampton, MA 01060 Two Sets of Structural Plans �r°F "moo 413- 587 -1240 Fax 413 - 587 -1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE INFORMATION 1.1 Properly Address: This section to be completed by office t ::, 7LGe— Map Lot Unit r Zone _ Overlay District ` 4 _ ,q" (Am 6'V � G Elm St District CB District SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: � j�A.44.'f'ht4.,/ 7€ Cir 1 44. 1 4/. /4 �C� se� /g8" eiA -v ', S I , v 4-Ap bt"/ d/ Name (Print) ,�� Cu�rrent ailin d s: i�i , Telephone / ,� i ` » 7 4" 3 3 7 73 %S Signature 2.2 Authorized Agent: / / � 'as � 1 t �4 _ � ik p Name (Print) / ,/, Current Mailing Addre / /.� A. � - q',, — � � ,,r,/ Signatu Telephone u SECTI / 3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building 1 CO . rye (a) Building Permit Fee 2. Electrical arG (b) Estimated Total Cost of Construction from (6) 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection ea ciC 6. Total = (1 + 2 + 3 + 4 + 5) ' ij / 51 r a,Z. (IC) Check Number /g6i $3�9i 10 U ' This Section For Official Use Only Building Permit Ntkmber: ‘ IIsssued. Signature: Building Commissioner /Inspector of Buildings Date File # BP- 2012 -0122 APPLICANT /CONTACT PERSON RICHARD R RUTH ADDRESS/PHONE 15 MAPLE ST TURNERS FALLS (413) 863 -9334 PROPERTY LOCATION 188 EARLE ST MAP 38A PARCEL 065 001 ZONE SI(97)/URC(3)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out *5// c) Fee Paid J f Typeof Construction: CONSTRUCT 20 X 37 2 STORY ADDITION New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: _ Owner/ Statement or License 07762 3 sets of Plans / Plot Plan THE F OWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF ATION PRESENTED: Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management olitio D y 47 Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. 188 EARLE ST BP- 2011 -0976 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38A - 065 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: vinyl siding BUILDING PERMIT Permit # BP- 2011 -0976 Project # JS- 2011- 001599 Est. Cost: $800.00 Fee: $35.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: Homeowner as Contractor Lot Size(sq, f1,1:_10802..88 Owner: YOURGA JONA. 'H?N& PAUL.INE PARKER Zoning: SI(97)/URC(3)/ Applicant: YOURGA JONATHAN & PAULINE PARKER AT: 188 EARLE ST Applicant Address: Phone: Insurance: 188 EARLE ST (413) 584 - 3027 0 NORTHAMPTONMAO1060 ISSUED ON :5/27/2011 0 :00 :00 TO PERFORM THE FOLLOWING WORK: REMOVE SIDING FOR PREP OF ADDITION POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: I .°uiation: Final: Smoke: Final: 0k THIS PERMIT MAY BE REVOKED BY THE CITY • ' NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND RE I S. / 1 6444 / 4 ,0440 6, Certificate of Occupan Signature: FeeTyp Date Paid: Amount: Building 5/27/2011 0:00:00 $35.00 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner