23A-281 (15) c2 — ) • RYAN S. HELLWIG PE • STRUCTURAL ENGINEER • September 12, 1996 ;‘H OF Anthony Patillo � ` Building Commissioner ?E h � , City of Northampton Na app Re: Roof /Wall Framing ES S10NAl EN 225 Nonotuck Street Florence MA I made an inspection of this building today. Based on my experience with older residential buildings, I concur with you that this is a unique method of construction. 3" x 4 -1/2" rafters, spaced at about 30" centers, span about 20' across the width of the building. Collar ties (also functioning as ceiling joists) are located at about the rafter midheight. At the eaves, the rafters bear on a 7" x 7" beam which runs along the length of the building (about 28' - 6 "). This beam is located on the outside of the building, attached directly to the outside face of the studs. In what is the most unusual feature of this house, the studs are set on the flat and spaced tightly together. Because the house has sloped ceilings in the second floor, these studs are only about 4' high there. The aluminum siding and older clapboards behind it appear to be attached directly to these studs, without a sheathing layer. The second floor joists span in a direction perpendicular to the rafters. The outermost joist is tight against these flat studs. Although the connection is not visible, this joist is probably nailed to the studs, with the second floor subfloor tying the two eave walls together. The eave beam on the south side had been exposed by local demolition of the roofing and siding. The condition of this beam, as you know, is not good. There is considerable insect damage and rot, particularly near the center of the span. Considering the unconventional construction and the decayed condition of the eave beam, the lines of the building are surprisingly good. The ridge and the walls are straight on both sides of the house. Because of the unusual framing here, in order to determine the level of code compliance I would have to create a full three - dimensional computerized structural model. Furthermore, I would require considerable probing to determine nailing schedules and other connection and framing details that are currently not visible. I think that this is beyond the financial capacity of the owners of this building. Furthermore, they are planning to remove the existing slate and wood shingle roof, and to install plywood sheathing and asphalt shingles. This will reduce the dead load slightly and stiffen the roof diaphragm considerably. They will also have to replace the eave beam with a built -up section of similar dimensions. This will have to be lag screwed from the outside, and the individual plies should be thoroughly glued together. However, in my opinion, the main structure which is resisting the thrust of the rafters is the cantilever action of both the rafters past the collar ties and the flat studs above the second floor. A continuous row of flat studs is actually stronger and stiffer than 2x4's on edge at 16" centers. A 28' -6" long 7x7 is much more flexible than flat studs cantilevering only 4'. Also, the almost total loss of section at midspan (without noticeable wall spread or ridge sag) leads me to believe that the eave beam does not span between the gable end walls. Therefore I feel that this repair, although it might not bring the structure up to current code, should restore it to better than its original capacity. Sincerely, Ryan ellwig • 28 ALDRICH STREET • NORTHAMPTON, MA 01060 • • VOICE 413 - 584 -HLWG (4594) • FAX 413 - 584 - HLWFax (4593) • der a 'v > ? 7j '0 I T r► z 3 a :.l - Z n _ 7l 7 - c' "n cn O -1 n ' O 70 _ ry O 1 Zoning Miscellaneous Additions, Repairs, Alterations, etc. Tel. No. Alterations �'r NORTHAMPTON, MASS. �'+� 1 9 Additions t' ti,: Repair .. APPLICATION FOR PERMIT TO ALTER = Garage 1. Location - Lot No. 2. Owner's name /'' i'' - Address - `, - 3. Builder's name t - r Address Mass. Construction Supervisor's License No. `� ' ' „. Expiration Date - - ; s. 4. Addition 5. Alteration 6. New Porch 7. Is existing building to be demolished? , ' 8. Repair after the fire 9. Garage No. of cars Size 10. Method of heating 11. Distance to lot lines 12. Type of roof r A ' M ' .. 13. Siding house i 14. Estimated cost:- " ), The undersigned certifies that the above statements are true to the best of his, her knowledge and belief. !Signature of responsible appucant Remarks 10. Do any signs exist on the property? YES NO / IF YES, describe size, type and location: Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: 11. ALL INFORMATION MUST BE COMPLETED, or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION. This column to be filled in by the Building Department Required Existing Proposed By Zoning Lot size Frontage Setbacks - front - side L: R: L: R: - rear • Building height Bldg Square footage %Open Space: (Lot area minus bldg &paved parking) # of Parking Spaces #' of Loading Docks Fill: (volume - -& location) 13. Certification: I hereby certify that the information contained herein c is true and accurate to the best of my knowledge. _3 DATE: 9 APPLICANT 's SIGNATURE r; NOTE: Issu n e of a zoning permit does not relieve an applio f /t rden to comply with all ..> zoning requirements and obtain all required permits from the Board of Health, Conservation Commission, Department of Publio Works and other applicable permit granting authorities. '';r FILE # • 6 • File No. ( 26/ 4 i3 ZONING PERMIT APPLICATION ( §10.2) PLEASE TYPE OR PRINT ALL INFORMATION 1. Name of Applicant: Address: 1 ,., Telephone: 2. Owner of Property: Address: x �, . , .. > Telephone: - .. , 3. Status of Applicant: Owner Contract Purchaser Lessee Other (explain): 4. Job Location: Parcel Id: Zoning Map# Parcel# 8 District(s): C 2 (TO BE FILLED IN BY THE BUILDING DEPARTMENT) 5. Existing Use of Structure/Property 6. Description of Proposed Use/Work/Project/Occupation: (Use additional sheets if necessary): 7. Attached Plans: Sketch Plan Site Plan Engineered /Surveyed Plans Answers to the following 2 questions may be obtained by checking with the Building Dept or Planning Department Files. 8. Has a Special PermitNariance/Finding ever been issued for /on the site? NO DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DONT KNOW YES IF YES: enter Book Page and /or Document # F 9. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW ;" YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , date issued: (FORM CONTINUES ON OTHER SIDE) FILE # ) $ qqt7 SE, `' 6 ' APPLICANT /CONTACT PERSON: Lf '! 6 _ ic___ : �X'' - .5/7 ADDRESS/PHONE: /// /r la: .' 7. w e , e / &' 3 PROPERTY LOCATION: V3 /�i/e‘�'' , ' / m n . - 2 ' ,� a a .f er - .... MAP e )9 PARCEL: 6?7/ ZONE , 'r. s THIS SECTION FOR - OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLET) OTTT Fee Paid Building Permit Filled nut Fee Paid (/ /9/ ,�D � 4) V' Tyre of Cnnctr•nrtinn• New C'nnstrnrtinn --- I, .„a Y.1.' Remndeling Tnterinr Z 2? ( lit it -Q,. Addition to FYisting ./V ___ 4e- it Sh - p A ccessory Strnrtnre c Q�0e� i Building Plans Tnrinded• - / Owner /Occupant Statement n T.irenc t!- C ` 4 (, L 'CP 1.--- 3 Sets of Plans / Pint Plan THIEFriOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION: , Approved as presented/based on information presented Denied as presented: Special Permit and/or Site Plan Required under: § PLANNING BOARD ZONING BOARD Received & Recorded at Registry of Deeds Proof Enclosed Finding Required under: § w /ZONING BOARD OF APPEALS Received & Recorded at Registry of Deeds Proof Enclosed Variance Required under: § w /ZONING BOARD OF APPEALS Received & Recorded at Registry of Deeds Proof Enclosed __ Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval -Bd of Health Well Water Potability -Bd Health Permit from Conservation Co ISM ission _ /...'... // �, A0 , Signature of Bui 11 f L e o ' Da NOTE: Issuanoe of a zoning permit does not relieve an applicant's burden to oompty with all zoning requirements and obtain all required permits from the Board of Health, Conservation Commission, Department of Public* Works and other applioable permit granting authorities. ° � " � 'o, • City of Northampton REQUIRED INSPECTIONS Mc••- 1'e 1. Footings and Walls BUILDING DEPARTMENT 2. Structural Components in Place* 3. Complete Building* No. 797 Office of the Building Inspector Zoning Form No. 961423 Date9 /10/96 Fee $40.00 Check # 191 Page, 23A Parcel 281 , Zone GI Section 127 ❑ Yes 0 No BUILDING PERMIT * Plumbing and Electrical Inspections required THIS CERTIFIES THAT Larry Yentsch before Building Inspections has permission tcetrip slate, install plywood, reshingle, repair soffitt, fasc aspection on Site — Foundations & rake boards as needed. Inspection of Plumbing situated on 97 5 Nonotiick St - Robert & Sally Lampron spec provided that the person accepting this permit shall in every respect Inspection of Plumbing — Finish conform to the terms of the application on file in this office, and to the Gas Inspection provisions of the Statutes and the Ordinances relating to the Construction, Inspection of Wiring —Rough Maintenance and Inspection of Buildings in the City of Northampton. Any violation of any of the terms above noted is an immediate revocation Inspection of Wiring — Finish of this permit. Expires six months from date of issuance, if not started. Building Inspection — Rough Note: A certificate of occupancy will be issued by this office upon return Insulation Inspection of this card signed by the Plumbing, Wiring and Building Inspectors. Building Inspection— Finish Smoke Detectors (Fire Department) Other THIS CARD MUST BE DISPLAYED IN A CONSPICUOUS PLACE ON ' ',�> ISES Certificate of Occupancy Inspector cothi 1:jiJf r ►iM;