36-331 (5) TEMPERATURE CONTROLS: [ ) Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and /or cooling input to each zone or floor shall be provided. HVAC EQUIPMENT SIZING: [ ] Rated output capacity of the heating /cooling system is not greater than 1250 of the design load as specified in sections 780CMR 1310 and J4.4. MISC REQUIREMENTS: [ ] Refer to 780 CMR, Appendix J for requirements relating to swimming pools, HVAC piping conveying fluids above 120 F or chilled fluids below 55 F, and circulating hot water systems. - -- -NOTES TO FIELD (Building Department Use Only) 4AScheck INSPECTION CHECKLIST Massachusetts Energy Code MAScheck Software Version 2.0 DATE: 2 -10 -2003 Bldg. Dept. Use CEILINGS: [ ] 1. R -38 Comments /Location WALLS: [ ] 1. Wood Frame, 16" O.C., R -15 + R -3 Comments /Location WINDOWS AND GLASS DOORS: [ ] 1. U- value: 0.40 For windows without labeled U- values, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments /Location DOORS: [ ] 1. U- value: 0.35 Comments /Location FLOORS: [ ] 1. Over Unconditioned Space, R -19 Comments /Location AIR LEAKAGE: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. VAPOR RETARDER: [ ] Required on the warm -in- winter side of all non - vented framed ceilings, walls, and floors. MATERIALS IDENTIFICATION: [ ] Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R- values and glazing U- values must be clearly marked on the building plans or specifications. DUCT INSULATION: [ ] Ducts in unconditioned spaces must be insulated to R -5. Ducts outside the building must be insulated to R -8.0. DUCT CONSTRUCTION: [ ] All ducts must be sealed with mastic and fibrous backing tape. Pressure- sensitive tape may be used for fibrous ducts. The HVAC system must provide a means for balancing air and water systems. MAScheck COMPLIANCE REPORT Massachusetts Energy Code Permit # MAScheck Software Version 2.0 Checked by /Date CITY: Springfield STATE: Massachusetts HDD: 5955 CONSTRUCTION TYPE: 1 or 2 family, detached HEATING SYSTEM TYPE: Other (Non- Electric Resistance) DATE: 2 -10 -2003 DATE OF PLANS : 2�E' /2-z' T TITLE: /67"---(3 7 .77e / % COMPLIANCE: PASSES Required UA = 728 Your Home = 522 Area or Insul Sheath Glazing /Door Perimeter R -Value R -Value U -Value UA CEILINGS 1150 38.0 0.0 34 WALLS: Wood Frame, 16" O.C. 4789 15.0 3.0 320 GLAZING: Windows or Doors 239 0.400 96 DOORS 49 0.350 17 FLOORS: Over Unconditioned Space 1150 19.0 55 COMPLIANCE STATEMENT: The proposed building design represented in these documents is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the requirements of the Massachusetts Energy Code. The heating load for this building, and the cooling load if appropriate has been determined using the applicable Standard Design Conditions found in the Code. The HVAC equipment selected to heat or cool the building shall be no greater than 1250 of the design load as specified in sections 780CMR 1310 and J4.4. Builder /Designer Date • 1 � CITY OF NORTHAMPTON, MASSACHUSETTS a" • ._TOti �, DEPARTMENT OF PUBLIC WORKS tr' , r) 125 Locust Street Northampton, MA 01060 413- 587 -1570 Fax 413 - 587 -1576 Samuel B. Brindis, P.E. Director, City Engineer Guilford B. Mooring, P.E. Assistant Director of Public Works BOARD OF PUBLIC WORKS DRIVEWAY PERMIT • GENERAL INSTRUCTIONS AND REGULATIONS 1. A "Driveway Permit" is required in all cases where a new curb cut or an alteration to an existing curb cut is proposed on a City public way. 2. Driveway permits issued by the Board of Public Works (BPW) shall be attached to and become part of the "Building Permit" issued by the Building Inspector. 3. Prior to the issuance of a "Building Permit" the owner of any lot to be serviced by a new driveway shall apply to the BPW for a "Driveway Permit" by completing the pertinent portions of the permit (see attached). Once the location of the driveway is approved by the BPW, a building permit may be issued. 4. The Building Inspector shall not issue an "Occupancy Permit" unless the driveway to the lot has been approved by the BPW. 5. By the issuance of a driveway permit for the stated location, neither the City of Northampton • nor the Department of Public Works imply that no drainage problems will result with the driveway when constructed. Properties situated or driveways installed in low lying areas in the path of the natural drainage will be subject to water problems. These problems may include water sheeting across roadways adjacent to the driveway. The City and the DPW assume no responsibility for any such drainage problems. The owner of the property is responsible for constructing and maintaining the driveway with adequate provision for natural water runoff situations. Wgnuel B Brindis, P.E. Director of Public Works CAMyFiles \Lyn \Drivewav Permit General Instructions y Permit No. D25 -03 Conditions: Driveway Permit In lieu of plan approved by City Engineer I agree to the following added conditions: 1. I will contact the Department of Public Works and have an inspector check and approve the graded gravel base prior to paving to insure compliance with slope and location; 2. I further agree that if in the inspections any of the permit conditions are not met that I will at no expense to the City remove and replace the driveway as directed by the City Engineer. By P e ,eoner Thomas Boyle, Autumn Properties Construction P.O. Box 628, Easthampton, MA 01027 413 - 527 -1580 Note: The Public Works Department recommends that you provide a plan showing the proposed driveway with grades and location in the future to avoid possible expense which you will incur by not getting approval of actual plans in advance. cc: Building Inspector Permit No. D25 -03 1 y CITY OF NORTHAMPTON, MA DRIVEWAY PERMIT Date: 10 -29 -02 FEE: $25.00 CHECK #: 1408 THE BOARD OF PUBLIC WORKS The undersigned respectfully petitions your honorable body for: Permission to install a driveway at 140 Cardinal Way Lot # 27 Fifteen (15) foot maximum width at the street line. Gutter drainage not to be disturbed. All drainage shall be directed off the driveway surface to adjacent land and not on the existing roadway. Driveway surface to be paved if the grade of the proposed driveway exceeds 3% or more. By: , ii 7'21? Thomas Boyle, Autumn roperties Construction P.O. Box 628, Easthampton, MA 01027 Telephone #: 413- 527 -1580 Proposed Location Inspected By: �-.. � /0/3//a -2 Gravel Base Grade Inspected By: Final Approval THE BOARD OF PUBLIC WORKS voted that petition be granted. George Andrikidis Director of Public Works (SUBJECT TO ATTACHED CONDITION I & 2) cc: Building Inspector MtNNICIPAL WATER AVAILABILITY Northampton Water Department 237 Prospect St. Northampton, MA 01060 587 -1098 Location: 140 Cardinal Way Lot # 27 Inquiry Made By: Thomas Boyle 413 - 527 -1580 Autumn Properties Construction Date of Inquiry: 10 -29 -02 Municipal Water Main in Front of Location: Yes x No Size of Water Main: 12" Material: DI Age: 2002 Approximate Street Pressure: 72 PSI Size of Service Connection: 1" copper Comments: The Water Department cannot guarantee adequate water pressure during peak demand times at elevations above 320 feet. The City of Northampton has not accepted responsibility for the maintenance of the water main and service connections as of this date of inquiry. A corresponding "water entrance fee" shall be paid prior to making any connection to the municipal water system. Arrangements of such installation shall be made with the Northampton Water Department with a minimum of 5 working days notification. All work shall conform to Northampton Water Department specifications. Y bsti,c_ Charles Borowski, Superintendent of Water cc: Ned I luntlev, As ('itv l:n1ineer Anili l,uildine lnspoci n W16 -03 Water Entry Application DATE: cc r,79q SIGNED: A li i s Name : le h ne No. can e o Thomas oyle, Aut r operties)Construction P.O. Box 628, Easthampton, MA 01027 (Address of Applicant) 413- 527 -1580 $ 200.00 entry fee paid. Check No.: 1406 $ 200.00 meter fee paid. Check No.: 1406 Application approved and permit issued: DATE: (O r O' a iv SIGNED: ? t 014 4 7( - - C-7 (Director of Public Works) FEE SCHEDULE: Water Entry. Permit Fee = $200 Water Meter Fees: 5/8" Meter = $100 3/4" Meter = $150 1" Meter = $200 ( I'L `,`, inu, W16 -03 RESIDENTIAL OR COMMERCIAL BUILDING WATER APPLICATION To the City of NORTHAMPTON, MASSACHUSETTS: The undersigned, being the Owner of the Owner, Owner's Agent property located at 140 Cardinal Way Lot #27 a does (Number) (Street) hereby request a permit to install and connect a 1 " Water (Size) Service to the Residence at said location. (Residence, Commercial Bldg., etc.) 1. "Owner shall mean the person holding title to the property served or to be served by the water service. 2. The name and address of person or firm who will perform the proposed work is Dietz Construction 527 -2695 134 Lovefield Street, Easthampton, MA 01027 3. Plan /Sketch and specification for the proposed water service shall be attached to permit. In consideration of the granting of this permit, the undersigned agrees: 1. The Water Department shall make all taps to the water main. 2. WATER ENTRY PERMIT fee is $200.00. 3. Additional work performed by City forces from the water main to streetline shall be paid at the prevailing labor rates and cost of material. Water Meters 5/8" $100.00 3/4" $150.00 1" $200.00 Water Meters 1 1/2" and above shall be purchased by the owners - using city specs. 4. The Water Superintendent shall be notifed for water line inspection prior to backfill of trench. 4. '11TUNICIPAL SEWER AVAILABILITY Northampton Streets Department DEC 1 125 Locust Street Northampton, MA 01060 587 -1570 Location: 140 Cardinal Way Lot 1! 27 Inquiry Made By: Thomas Boyle 413 - 527 -1580 Autumn Properties Construction Date of Inquiry: 10 -29 -02 Municipal Sewer Main in Front of Location: Yes g No Size of Sewer Main: 2 " Material: PVC Age: 2002 • Depth of Sewer Main: 5 Size of Service Connection: 1 -1 PVC Comments: The City of Northampton has not accepted responsibility for the maintenance of he sewer main and service connections as of this date of inquiry_ A corresponding "sewer entrance fee" shall be paid prior to making any connection to the municipal sewer system. Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department specifications. Joseph Thomas, Superintendent Streets Department cc: Ned Huntley, Asst. City Engineer Anthony Paid In, Building Inspector Page 2 R.C.B.S.A. 4. The City shall not be held liable for and open plumbing fixtures below street level. 5. The applicant and /or owner hereby agrees to pay to the City any sewer use assessments or charges as may be established under city ordinance. DATE: �( aei BOoL SIGNED: /r / (Appli ant) Thomas Boyle, Autumn Properties Construction P.O. Box 628, Easthampton, MA 01027 (Address of Applicant) 413- 527 -1580 $ 200.00 Check No. 1407 inspection fee paid. Appl i :cat ion approved and permit isued: DATE:/�.3/ SIGNED: V Superintenden Attachments: Code of Ordinances, Section 22 -41 through 22 -46. Tie -in to sanitary main $200.00 X Tie -in to sanitary service at street line $500.00 Tie -in to storm drain $100.00 • S23 -03 FORM 79 - RESIDENTIAL OR COMMERCIAL BUILDING SEWER APPLICATION To the City of NORTHAMPTON, MASSACHUSETTS: The undersigned, being the Owner of the (Owner, Owner's Agent) property located a t 140 Cardinal Way Lot #27 ,does (Number) (Street) hereby request a permit to install and connect a building sewer to serve the Residence at said location. (Residence,Commercial Bldg., etc.) 1. The applicant and /or owner shall furnish upon request of the Superintendent the estimated quantity and characteristics of waste to be discharged to the public sewer. 2. "Owner" shall mean the person holding title to the property served or to be served by the building sewer. 3. The name and addre v i et o z f Co n s tr u o c t ion f 4 r 1 r 3 m 5 2 WW7h 11 perform the proposed work i s 134 Lovefield Street, Easthampton , MA 01027 • 4. Plans and specifications for the proposed building sewer are attached hereunto as Exhibit "A ". In Consideration of the granting of this permit, the under- signed agrees: 1. To accept and abide by all provisions of the Code of Ordinances, City of Northampton, Massachusetts, Sections 22 -41 through 22 -46, and all other pertinant ordinances or regulations that may be adopted in the future. 2. To maintain the building sewer at no expense to the city. 3. To notify the Superintendent when the building sewer is ready for inspection and connection to the public sewer, but before any portion of the work is covered. F ° . oYa3o- O �(tlAlf plQ 1 ti B �iL_� Ate , (rxt of azt.f 1ttt #utt ' _ # °� 4I " B � i " 1 • assnchnsctte I2 = = . ciy. -DEPARTMENTi OF BUILDING INSPECTIONS ( , i _ INSPECTOR _ Main Street • Municipal Building \ c , , Northampton, Mass. 01060 Square Footage Amount Basement @ .10 g' 0 /6i2' O 1st Floor @ .40 it:), i 2nd Floor @ .20 7 67 /� y 1'717 1/2 Floors, Attic, Garage .10 4/4-4 4 � Deck, Porches - /, ><%'i r% fi // � • , TOTAL / Yo. _ - -j--/ I t....A ,K - . 1 ( & / ' V/ / - / 7 7 i did,L) - 7 - 4 , 7i0,, i / ----- e -- e , „., t (ltf)? ref Nr7x tIt&inpfrltt _ t1 c6 f3iasaxcflttrrtis }� : • DEPARTMENT OF BUILDING INSPECTIONS j1 E3 212 Main Street Municipal Building Northampton, Mass. 01060 ttr' WORKER'S COMPENSATION INSURANCE AFFIDAVIT (li censcr/perrni (tee) with a principal place of b>_i_sb ess/residence at (strer ty /staieJni p) do hereby certify, under the pains and penalties of perjury, that ( an an employer providing the following workers compensation coverage for my employees working on this job: ✓ sT Zri.:5t.41VV L LVelliozni 06 6 6 — y� 50e6 - (In_su Company) (Polio Number) (Expiration Date) ( ) I am a sole proprietor, general contractor or homeowner (circle one) and have hired the contractors listed below who have the followil. workers compensation policies: (Name of Contractor) (Insurance Company /PoGef Number) (Expiration Date) (Name of Contractor) (Insurance Com any/Po!icy Number) (Expiration Date) (Name of Contractor) (Insurance Companyi olicy Number) (Expiration Date) (Name of Contractor) (Insurance Comnany/Folicy Number) (Expiration Date) (attach additional sleet ifncccaury to inoluc. information pctaioi_5:n ( ) I an a sole proprietor and have no one working for me. ( ) I am a home owner performing all the work myself. NOTE: ptc ac be awarr that Wlulc bOCIKOwIY_T3 w') employ T.a;t:tc- nancc, a r ^ im c repair work on a dwciling of not met than thmo units in wivdt the botnGOSVOCC trsidcs cr co Ltic ua'_s z u c: f thcrcto tot oc( generally cxJidcral to be carployrra ucdcr the workcrt axnpcsatico Act (GL152 n1(5)), application by a hotnonwncr for license cc pct may c.idcmc the legal etatirc of an omptoyer under tho Wockees Compmvlion Act I undczittnd th.: z copy of thin ctatcizerrt may ho forwoudo<i to rho Dcpa,t:rrnm of Industrial Acci&n ? Offioa of ln:ur.nco for the coverage verification and that failure to :xtue eovcsago und;s section 25A of MGI, 152 can lead to the imposition of criminal penalties oomisting of a hoc of up to S1.500.00 ontt'cc imprisoarnaL of up to one }tar and civil penalties in the form of a Step Work Otdc and a firm of S100.00 a thy agzintt Fcr dcputmaCal uao colt' d _ l I Permit Number t ..4) M.ap # ht# Signature of LiccnscsJ rm.itt + Fete r-k SECTION 8 - CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable 0 Name of License Holder : �1iJ MCL S _s� —Ti - -- - - - -- '�! License Number Ad ess Expira Date Signature Telephone : 9 Registered Haire improvertier f Contractor =rtr ,,,. , , ,, Not Applicable p. Company Name Registration Number Address Expiration Date Telephone SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G "L" c" 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance f the building permit. Signed Affidavit Attached Yes No ❑ 11 ® omen mOttoli The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work fe- which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) - New House Ye' Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors ❑ Accessory Bldg. ❑ Demolition❑ New S:gns [ ] Decks Siding [ ] Other [ ] J 7 : i`j"I / ■-R . ti../Eg gtom Brief Description of Proposed Work: i t—� lcrj / if Alteration of existing bedroom Yes //No Adding new bedroom Yes No Attached Narrative ❑ Renovating unfinished basement Yes No Plans Attached Roll [1.- U 6a. If "New.:house_antl or- 'addition tto existing housing, complete the following: a Use of building : One Family C/ Two Family Other b Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? y 7 5 d Proposed Square footage of new construction. .23.2-07 D ifi i r'ldr•- e. Number of stories? 02. f. Method of heating? J !replaces or Woodstoves f/ Number of each 4 g. Energy Conservation Compliance. Mascheck Energy Compliance form attached? h. Type of construction 4,/��77, Is construction within 100 ft. of wetlands? 2,/"Yes _ No. Is construction within 100 yr. floodplain Yes _No j. Depth of basement or cellar floor below finished grade C i k. Will building conform to the Building and Zoning regulations? /1 Yes No .. I Septic Tank City Sewer // Private well City water Supply SECTION 7a; OWNER- AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR "CONTRACTOR APPLIES FOR BUILDING PERMIT , as Owner of the subject property hereby authorize _ _ to ac; or my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date '"71/rll - 14S r" 6 as Owner/Authorized Agent hereby declare that the staternente and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name — — �_ -- — —_ — del ( a, . L i - — - — -- - Signature of •w er /Agent / Date • Section 4. ALL INFORMATION MUST BE COMPLETED, or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION Existing Proposed Required by Zoning This column to be filled in by �J Building Department Lot Size / / / - S , r � � j 5 5 - . : — Frontage J //5- 5 Setbacks Front i Side L: R: 0' L: /7 R: Rear C. 0• :' Building Height a I � 25 " Bldg. Square Footage °i°` .2 8 ` o6 Open Space Footage % / S5 y 4 ,. - (Lot (Loki e minus bldg & paved 0 6 /-5l0 ( Q ) � 3.),4 4-7 1 � ti of Parking Spaces _ 7 Fill: volume & Location) L. y � /5✓ /A� L� ^ /� d A. Has a Special Permit /Variance /Finding ever been issued for/on the site? NO g, DON'T KNOW YES C� IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES G''' IF YES: enter Book 7 3 Page /'7 - 1 and /or Document # 9 4/6"S' B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commis ion? Needs to be obtained Obtained �/ , Date Issued: Y4,2376`.. C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ?YES No IF YES, describe size, type and location:_ . % ___ •__ r arty of Northampton Status o f ' Permit 3 t1 '; , . - Building Department CurbGut /D�euvay ° ° - ga. �,, 212 Main Street S /S at labt a � �o ,. ` f . Room 100 Water /Well A� ,''0 a F' . i _: rn Northampton, MA 01060 Two Sets ' c ural ° ans " � C 1 f hon - e 413- 587 -1240 Fax 413- 587 -1 -=? Plot /Site Pla s : g- K a t Other ecify P APPLICATIONTO CONSTRUCT, ALTER. REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING ' f SECTION 1 - SITE INFORMATION This section to be completed by office 1 . 1 Property Address: //61 L: - iv / Map 3 "` Lot 33 � Unit f r5,v / ( 4 D ( 4 , / . i / Zone Se......, Overlay District 1,6 I Elm St. District CB District SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2_1 Owner of Record: 1 73? ! rr�Arne�5 L . 1, ( t ,C c=A �� /1 -�/`?� Name Print) . ,. rent Mailing Addres L ,12 1 ,6/KkPt° / i t 0' - r eptinne Signature 2.2 Authorized Agent: f b ), M - 75 - 0,/,--e a .3e) a% /).-P , ,r Name (Print) „r urrent Mailing ) g Address: X J27/if Cpl( 02 /Z2 5 J Signature Telephone SECTION 3- ESTIMATED CONSTRUCTION COSTS hem Estimated Cost (Dollars) to be Official Use Only completed by permit applicant ). Building (a) Building Permit Fee I 2. Electrical � _ - (b) stimated Total Cost of _I__ r� Construction from (6) 3. Plumbing 1 n,---e:, Building Permit Fee 4 Mechanical (HVAC) I /� - __--_- 1 5. Fire Protection /,/� 6. Total = (1 + 2 + 3 + 4 + 5) 2/:,,2� S' _ Check Number f This Section For Official Use Only Building Permit Number: — I Date Issued: c'o -- Signature: -- - — — -- - -- Building Commissioner /Inspector of Buildings Date • • File # BP- 2003 -0566 APPLICANT /CONTACT PERSON AUTUMN PROPERTIES LLC ADDRESS /PHONE P 0 Box 628 (413) 527 -1580 THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Peimut Filled out / ,�/ 3 fit/ p ! o Fee Paid / � y/� l b 'T Typeof Construction:_CONSTRUCT 2 STORY SFH W /ATT GARAGE /DECK New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 04443 � 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF ATION PRESENTED: A pproved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Stre9I;Commission O O'" Signature of Buildin Offi 1 Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. e(r' /mac t 4 A, SrG e S Y .f.72- d i s 6d4-4r vt r .�:/� �o des p./4 s p Plumbing ❑ Building Electrical ❑ • City of Northampton BUILDING INSPECTION LABEL PP OVED z I n spector ! "' Date 1'1 - 140 CARDINA WAY - LOT #2� BP- 2003 -0566 GIs #: COMMONWE OF MA SSAC HU SETT S Map:1 36 - 331 CITY OF NORT Lot: -001 Permit: Building Category: BU Il DING PE�;M BP- 2003 -0566 Permit # Project # JS- 2003 -0929 Est. Cost: $212000.00 Fee: $1008.40 PERMISSION IS HEREBY GRANTED TO: Const. Class: 5B Contractor: Li cense r Use Group: R4 AUTUMN PR OPERTIES LLC 044431 Lot Size(sq. ft.): Owner: AU T UMN PROPERI LLC zoning: SR Applicant: AUTUMN PROPERTIES LLC AT: 1 40 CARDINAL WAY LOT #2 Applicant Address: Phone: Insurance P ® 628 (413) 527 -1580 Workers Compensat EASTHAMPTONMA01027 IS SUED ON:3/6/ 0:00:00 TO PERF ORM THE FOLLOWI WORK CONSTRU 2 STORY SFH • W /ATT GARAGE /DEC . POST THIS CA SO IT I VI SIBLE FROM THE STREET e Inspector of Plumb Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: / Footings: Rough:.��_ �, Rough: House # Foundation: 7 = Driveway F inal: - _ Final: J �*° `ice jtr ,; Final: f/)Y 1 l 91 iO3� t -�'' S U� Rough Frame: (,k 7 3 — Gas?/37, Fire Department Firep /Chunne or TM �6 Rough: Oil: Insulation d S O 3 �� _ F " _ _ 1 Smoke: Fii►al -tg �� 1 THIS PERMIT MAY B ' —I r i ' r ° ' ' `Iti C ITY OF N ORTHAMPTO N , UPON V OF ANY OF ITS RULES AND REGULATIONS.. Certific of Occupa _ ��, Sig nature: FType: Receipt No: Date Paid: Check No: Amount: Building 3/6/03 0:00:00 1458 $1008.40 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Building Commissioner - Anthony Patillo