Loading...
36-399 a. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft at 1st floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 b. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 c. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 %" from the top of the threshold and only in- swinging doors. 780 CMR R311.3 13. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ", maximum riser 83/4", maximum overall variance for the run is 3/8 ", 4" sphere rule on risers, 4 3/8" on balustrade, 6" in the triangle. Graspable rail 1 %" minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 14. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36 ", 4" sphere rule. See 780 CMR R312.1. 15. Educate the plumber and electrician about maximum notch and hole sizes, and placement. See 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In interior non- bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1 16ga. strap must extend a minimum of 6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom. Notches are different. 16. Fire and draft stopping shall be completed before rough inspection. See 780 CMR R302. 17. Ignition barriers in place before final. See 780 CMR R316. 18. Energy aspects shall comply with the stretch energy code. See 780 CMR Appendix 115AA and 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. Energy information including mechanical equipment posted on the electric panel. d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Building Option Package. 19. Vapor retarders. Although these are still in the code there are exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer (diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99% of the moisture in a structure. This is evident every time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. See 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 20. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements See 780 CMR R806.4. 21. Deck ledgers and post must be appropriately attached, bolts or lags. See 780 CMR R502.2.2.1 Note: ThruLoks are engineered for post attachment supporting a railing. 22. Smoke and CO detectors as required. See 780 CMR R314 and R315. Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. Thank y. or •ur operation on these matters. uck it er - City of Northampton Assistant Commissioner and Zoning Enforcement cmiller a(� northamptonma.gov City of Northampton Massachusetts 4„, * c, DEPARTMENT OF BUILDING INSPECTIONS ` t*r ` 212 Main Street • Municipal Building Northampton, MA 01060 'Skk { INSPECTOR Kohl Construction November 29, 2011 31 Campus Plaza Road Hadley, MA 01035 Subject Property: 80 Emerson Way — Lot #55 Florence, MA 01062 Mr. Llyod Your plans dated 10 -28 -11 have been approved as noted. Please provide additional information noted. 1. HVAC Manual J calculations are required as well as sizing of ducts and equipment type /sizing. 2. Garage portal wall systems require specific criteria (straps & nailing) see 780CMR Figure 602.10.3.3. 3. Make sure all final riser heights are correct or they will need to be corrected, review finishes with framer. 4. If the basement ceiling is the bottom of the thermal envelope the insulation must be enclosed within, and substantially in contact with an air barrier. (covered both sides) 5. The shed dormer requires collar ties every 4' or strap ties over the ridge. The low pitch roof requires Ice and Water barrier over the entire roof section. As of August 4 2011 the 8 Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8 edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. See 780 CMR R401.3 for drainage requirements. 3. Where ceiling joists are not directly connected to the rafters, rafter ties are required and must be in the bottom 1/3` See 780 CMR R802.3.1. Minimum 2x4 16" OC nailed per 780 CMR Table R802.5.1(9) 4" slope 8 -16nd common at each connection. 4. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1/3` 780 CMR R802.3.1 5. Ridge boards must be the full depth of the cut 780 CMR R802.3. 6. A complete window and header schedule is required. See 780 CMR Table R502.5 for header sizing and number of jack studs required. 7. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss 8. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. See 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 9. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basement without habitable space, 6'4" at beams /ducts. 780 CMR R305.1. 10. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. See 780 CMR R308.4 11. Windows over 72" above grade with the opening Tess than 24 above the finished floor shall meet the 4" sphere rule. See 780 CMR R612.2 12. Egress and emergency escape requirements shall be strictly met. ` ( ! ' l '' +�..� � �~~~~~_.^_�-_� _-- _ _-�' QUICK ANALYSIS REPORT Date: November 18, 2011 Rating No.: 11 -428 Building Name: ‘ 90 Emerson Rating Org.: Center for EcoTechnology Owner's Name: Phone No.: 413 - 586 -7350 Property: g0 Emerson Way Raters Name: Romney Biddulp RECEIVED Address: Northampton, MA 01060 Raters No.: Builder's Name: Richard Lloyd NOV 2 1 2011 Weather Site: Northampton, MA Rating Type: Projected Rating File Name: 11-428 30 Emerson based on plans.blg Rating Date: 11 -18 -11 DEPT. OF BUILDING INSPECTIONS NORTHAMPTON. MA (N _ns Codes Programs IECC 2009 Performance: Fails EPA ENERGY STAR 2.0 Fails IECC 2006 Performance: Fails EPA ENERGY STAR 2.5 Fails IECC 2004 Performance: Fails , EPA ENERGY STAR 3.0 Fails IECC 2003 Performance: Fails j Tax Credit Fails �— IECC 20Q1 Performance: Passes ! HERS Index 70 IECC 2000 Performance: Passes IECC 1998 Performance: Passes ECC of NY Performance: Passes ECC of NV Performance: Fails MEC 1995 Performance: Passes MEC 1993 Performance: Passes MEC 1992 Performance: Passes ASHRAE 90.2 Performance: Passes REM /Rate - Residential Energy Analysis and Rating Software v12.96 This information does not constitute any warranty of energy cost or savings. © 1985 -2011 Architectural Energy Corporation, Boulder, Colorado. PLOT FILE CREATED: 10/25/2011 11:53:55 AM REVISIONS ^ , �� # Revision /Issue Mit Date , j 4;111/ 3 \ ` �r ,/!1/ f ; �y / — cij ,' , 1 'cP- L , /6 - ., I � I 86.5 „_ I ! 7 , I 1 3g. I I I J I 11• > ' I ' C p CO / i -N / / IV I // ' I a , i 1 �o / I 1 i / , � ' 4 , w o w / I ti I i / O , Q / I / / ` / 1 i / 1 .--. ti / ' /7 / 1 ' ' ., .,\ 59 4� s,� ; / 2/ '•iii - ..,...............( N 0 20' 40' Kohl Construction JOBNAM DATE HARP - SWEENEY RES. [lot# 55] 10.25.2011 SP-1 TITLE SCALE 31 Campus Plaza Road, Hadley, MA01035 Emerson Way, Northampton, MA 1" = 20' 1 OF 1 ph (413) 256 -0321 fx (413) 256 -0130 COPYRIGHT 0 KOHL CONSTRUCTION, INC Kohl Construction www.KohlConstruction.com 31 Campus Plaza Road, Hadley, MA 01035 ph (413) 256 -0321 fx (413) 256 -0130 #80 Emerson Way, Sweeney -Sharp Window Schedule Window Spec's: Pella Proline Series, double hung, casement and awning windows, white, Low E glazing, argon, screens, no grilles WINDOWS KEY # MFGR & TYPE MODEL # Pella Proline DH C, E2, 12 DH 2541 D2 DH 3347 C2 DH 3347 B2, F2, H2 DH 3353 G2 DH 3353 B, D, F DH 3359 G CSMT 2541 -2 LR J, 1 AWN 3529 -2 A2, J2 DH 3353 -2 A, H DH 3359 -2 E DH 3359 -3 I • • *=-- 1lassachusetts - Department of Puh ie Safety Board of Building Regulations and Standards Construction Supervisor License License: CS 96576 RICHARD LLOYD g 8 FOURTH AVENUE NORTHAMPTON, MA 01060 �-�— ---- y Expiration: 8/17/2012 ('omm issioner Tr#: 6249 11/10/2011 07:03 413- 256 -0130 KOHL CONSTRUCTION PAGE 03 gam. € r ∎ - ; rrf1E - - r �� i 0 � =`- f? _ DEPARTMENT OF DEG ,INSPECTOR 212Ivlthn Street • •MumagaI B ungling Nor, Ito 01060 LOCATION SQUARE FOOTAGB AMOUNT BASEMENT ® i c. • I "FLOOR ®SO • OS 1 I ` sS o FLOORS, FINISH ATTIC, GARAGE 20 __ - . • I3 fJECIE/iORCIES .20 _. . -! -: . TOTAL.. ..rt 4, • 11/10/2011 07:03 413- 256 -0130 KOHL CONSTRUCTION PAGE 02 The Commonwealth ofMaccaghuse {,"_ :� Department of Industrial Accidents s iii Office of Investigations — 600 Washington Street Boston, MA 02111 "' �� �' www.mass.govldia Workers' Compensation Insurance Affidavit: Builders/ Contractors /Electricians/Plumbers Applicant Information Please Print Legibly Name ( susinessfOrgnizationrindivdual): Kohl Construction, Inc. Address: 31 Campus Plaza Road, Suite 3 City /State/Zip: Hadley, MA 01035 Phone #: 256 -0321 Are you an employer? Check -the appropriate box: Type of project (required): 1. Si I am a employer with 1 4. ❑ I am a general contractor and 1 6. o New construction employees (full and/or part- time). * have hired the sub - contractors I 2. ❑ I am a sole proprietor or partner- listed on the attached sheet. t . 7 . 0 Remodeling ship and have no employees These sub - contractors have 8. [] Demolition . working for me in any capacity. workers' comp. insurance. 9_ [] .Building addition [No workers' comp. insurance 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions required.] officers have exercised their 3. ❑ I am a homeowner doing all work right of exemption per MGL 11.[] Plumbing repairs or additions myself. [No workers' comp. c. 152, §1(4), and we have no. 121 Roof repairs insurance required.] t employees. [No workers' i comp. insurance required.] t 13.0 Other •Any applicant that checks box #1 must also fill out the section below showing their workers' compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub - contractors and their wodrers' comp. policy information I am an employer that is providingworkers' compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: AIM Mutual Insurance Company Pdicv,## Silt' s.?.ic. R WMZ80i1.?A72Q1- 20 1.f) r x pration a , 021 Job Site Address: #80 Emerson Way, (Lot 55) Oak Ridge LLC City/State/Zip: Nottharnpton, MA, 01062 Attach a. copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the impoei ion of criminal penalties nfa fine up to $1,500.00 and/or one -year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do her c ' under the pains arc Haloes of perjury that the information provided above is true and correct Signature: : � Date: 11/10111 phone #: 413 256 -0321 , Official use only. Do not write in this area, to be completed by city or town official City or Town: Permit/License # Issuing Authority (circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical inspector 5. Plumbing Inspector 6. Other Contact Person: Phone 11: i SECTION 8 - CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: ^ Not Applicable ❑ Name of License Holder : R IC SR D `✓ (�(.0 - `�1' '✓ CS QC: ✓ 4-. j License Number 8 Rout P_Ti -1- ,PVC , 'WoR-TN,CIvI� OK) WA' $ / t'�- 2-012. Address Expiration Date ii �, � (i#.r:) S ) 2-3 ({- • Signature Telephone 9. Registered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number Address Expiration Date Telephone SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affiday must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the build' g permit. Signed Affidavit Attached Yes No ❑ 11. — Home Owner Exemption The current exemption for "homeowners" was extended to include Owner- occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) New House [A Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [D] Decks [Q Siding [D] Other [0] Brief Description of Proposed 5 W (/ 1, i � A 'jc ' ,� / 13 6 4. Work: Construct new house with attached garage, deck, and covered porch Alteration of existing bedroom Yes K. No Adding new bedroom Yes )C No Attached Narrative Renovating unfinished basement Yes ?EC No Plans Attached Roll - Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family x Two Family Other b. Number of rooms in each family unit: 10 Number of Bathrooms 2.5 c. Is there a garage attached? YES d. Proposed Square footage of new construction. 2 Dimensions 37'-6"x 29'; 2 1 X 21 e. Number of stories? 2 f. Method of heating? Nat Gas; Forced Hot Air Fireplaces or Woodstoves NO Number of each g. Energy Conservation Compliance. YES Masscheck Energy Compliance form attached? No h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No No. Is construction within 100 yr. floodplain Yes NO No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and oning regulations? YES Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES PAL BUILDING PERMIT - T t-} Eo t a R,E E . r A _ AL t R- , as Owner of the subject property / hereby authorize "�.1Gbl-s0 q. LA 1 E C) to act on my behalf, in all matters relative to work authorized by this building permit application. 0 o - NO v 2 Signature of Owner Date I - LG t--k-A 2 f C. t' , as Owner /Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. 1 A (LC> lb C).N Print Name i ,, 1 • Signature of Owner /Agent Date r Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size , .... Frontage '116.71' Setbacks Front 25' I _ Side L:20_ R: 21 .•.7 L :...._.... R: . ....; Rear 54.8 Building Height 29' Bldg. Square Footage % " ` °° _ 23 50 [2,3 119_... Open Space F (Lot area minus bldg & paved j 9,5 ;76,3 I parking) i # of Parking Spaces 2 _a ( ° ' Fill: (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO 0 DON'T KNOW 0 YES 0 IF YES, date issued:`,`, IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW Q YES IF YES: enter Book Page, 1 and /or Document # B. Does the site contain a brook, body of water or wetlands? NO 0 DON'T KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained ® , Date Issued: I I C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. t.; : Department use only City of Northampton Status of Permit: Building Department C urb cut/Driveway ermit 9 p � r /Septic y �Uy 1 2011 212 Main Street Sewe Availabi[ity Room 100 Water/Wetl Avai ab l "Ity ors rthampton, MA 01060 Tweets of Structural Plans u k roF 'u''" N :• • - .587 Fax 413 - 587 - 1272 Plot/Site Plans Other Specafy, APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE INFORMATION 1.1 Property Address: This section to be complete y office 5 8 a �W►�RSo� W4'( M a 3(42 Lot Unit 1 5 . / p OAK RI o ��pp Zone Sr`- Overlay District WORTHY .-P a►.3 , A..4 , 014 62- Elm St. District CB District SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: Oak Ridge Road LLC, Theodore E. Parker 31 Campus Plaza Road, Hadley, MA, 01035 Name (Print) Current Mailing Address: 413- 256 -0321 Telephone Signature 2.2 Authorized Agent: '12 tcbi -4,20 ' . l.l.c 1) 3 i (' 4VVIP (AS Pt,A A Dt.EY Name (Print) Current Mailing Address: VtA.4. / p l a -56 • <�r oifiiFA (t t3) 256 0 321 - ,c-r ( Signature Telephone SECTION 3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building 120,000 (a) Building Permit Fee 2. Electrical 11,000 (b) Estimated of Construction from (6) 3. Plumbing 12,000 Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 10,000 �( n 6. Total = (1 +2 +3+4 + 5) 153,000 Check Number (34',01 D(0 XY 60157 fO This Section For Official Use Only Date Building Permit Number: Issued: Signature: Building Commissioner /Inspector of Buildings Date File # BP- 2012 -0475 0 _ 1 A APPLICANT /CONTACT PERSON KOHL CONSTRUCTION ADDRESS/PHONE 31 Campus Plaza Rd HADLEY (413) 256 -0321 PROPERTY LCATION MAP 36 PARC 399 0g10ZONERSORN 00 )Y - LOT #55 W Uz -keke;S ed( E e.c7por' C — 1)2�w` / THIS SECTION FOR OFFICIAL USE ONLY: J PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out 3! n /, 9. / Fee Paid (0 q7 Typeof Construction: CONSTRUCT 2 STORY SFH W /ATT GARAGE/DECK/PORCH New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 96576 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFQRMATION PRESENTED: V Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management olition Delay Si: ature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. 80 EMERSON WAY - LOT #55 BP- 2012 -0475 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 36 - 399 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: New Single Family House BUILDING PERMIT Permit # BP- 2012 -0475 Project # JS- 2012 - 000787 Est. Cost: $153000.00 Fee: $1257.10 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: KOHL CONSTRUCTION 96576 Lot Size(sq. ft.): 12501.72 Owner: OAK RIDGE ROAD LLC CIO DOUGLAS KOHL Zoning: SR(100)/ Applicant: KOHL CONSTRUCTION AT: 80 EMERSON WAY - LOT #55 Applicant Address: Phone: Insurance: 31 Campus Plaza Rd (413) 256 - 0321 Workers Compensation HADLEYMA01035 ISSUED ON:11/29/2011 0:00:00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT 2 STORY SFH W /ATT GARAGE /DECK/PORCH POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 11/29/2011 0:00:00 $1257.10 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner