Loading...
38D-025 i I �, �, il�� b. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 c. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 3/4" from the top of the threshold and only in- swinging doors. 780 CMR R311.3 13. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ", maximum riser 8 % ", maximum overall variance for the run is 3/8 ", 4" sphere rule on risers, 4 3/8" on balustrade, 6" in the triangle. Graspable rail 13/4" minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 14. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36 ", 4" sphere rule. See 780 CMR R312.1. 15. Educate the plumber and electrician about maximum notch and hole sizes, and placement. See 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In interior non- bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1 Y2 16ga. strap must extend a minimum of 6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom. Notches are different. 16. Fire and draft stopping shall be completed before rough inspection. See 780 CMR R302. 17. Ignition barriers in place before final. See 780 CMR R316. 18. Energy aspects shall comply with the stretch energy code. See 780 CMR Appendix 115AA and 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. Energy information including mechanical equipment posted on the electric panel. d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Building Option Package. 19. Vapor retarders. Although these are still in the code there are exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer (diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99% of the moisture in a structure. This is evident every time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. See 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 20. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements See 780 CMR R806.4. 21. Deck ledgers and post must be appropriately attached, bolts or Zags. See 780 CMR R502.2.2.1 Note: ThruLoks are engineered for post attachment supporting a railing. 22. Smoke and CO detectors as required. See 780 CMR R314 and R315. Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. Thank you for your cooperation on these ma - s. Chuck Miller - City of Northampton Assistant Commissioner and Zoning Enforcement cmiller(a�northamptonma.gov City of Northampton 40 ro sr Massachusetts ' >'d ® .A �+ 7, 74' DEPARTMENT OF BUILDING INSPECTIONS I 212 Main Street • Municipal Building ` � Northampton, MA 01060t a jti '�` INSPECTOR Stephen Ferrari October 27, 2011 103 Ryan Road Florence, MA 01062 Subject Location: 24 Hampden Street Map Block: 38D - 025 Mr. Ferrari Your plans dated 07 -09 -11 have been approved as noted. 1. Full set of completed electronic plans be emailed to cmiller@northamptonma.gov 2. Engineering data for all non prescriptive materials. 3. CO detectors at each floor as noted, five total. 4. Metal strap ties over the ridge of the addition at 48" OC. 5. Window and header /jack schedule. As of August 4 2011 the 8th Addition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8 addition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. See 780 CMR R401.3 for drainage requirements. 3. Where ceiling joist are not directly connected to the rafters, rafter ties are required and must be in the bottom 1/3 . See 780 CMR R802.3.1. Minimum 2x4 16" OC nailed per 780 CMR Table R802.5.1(9) 4" slope 8 -16nd common at each connection. 4. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1 /3 780 CMR R802.3.1 5. Ridge boards must be the full depth of the cut 780 CMR R802.3. 6. A complete window and header schedule is required. See 780 CMR Table R502.5 for header sizing and number of jack studs required. 7. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss 8. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. See 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 9. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basement without habitable space, 6'4" at beams /ducts. 780 CMR R305.1. 10. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. See 780 CMR R308.4 11. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. See 780 CMR R612.2 12. Egress and emergency escape requirements shall be strictly met. a. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft at 1 floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 ,� Ef t., 2009 IECC. Energy Efficiency Certificate Insulation Rating R -Value Ceiling / Roof 63.00 Wall 43.15 Floor / Foundation 20.00 Ductwork (unconditioned spaces): Glass & Door Rating U Factor SHGC Window 0.20 Door 0.25 NA Heating & Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments: . Covers are not required when 60% of the heating energy is from site- recovered energy or solar energy source. Lighting Requirements: A minimum of 50 percent of the lamps in permanently installed lighting fixtures can be categorized as one of the following: (a) Compact fluorescent (b) T -8 or smaller diameter linear fluorescent (c) 40 lumens per watt for lamp wattage <= 15 (d) 50 lumens per watt for lamp wattage > 15 and <= 40 (e) 60 lumens per watt for lamp wattage > 40 Other Requirements: Snow- and ice - melting systems with energy supplied from the service to a building shall include automatic controls capable of shutting off the system when a) the pavement temperature is above 50 degrees F, b) no precipitation is falling, and c) the outdoor temperature is above 40 degrees F (a manual shutoff control is also permitted to satisfy requirement 'c'). Certificate: A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R- values; window U- factors; type and efficiency of space- conditioning and water heating equipment. The certificate does not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. NOTES TO FIELD: (Building Department Use Only) Project Title: Von Goeler Slough Residence Report date: 09/07/11 Data filename: Untitled.rck Page 4 of 4 (c) Above -grade walls: Insulation is installed in substantial contact and continuous alignment with the building envelope air barrier. (d) Floors: Air barrier is installed at any exposed edge of insulation. (e) Plumbing and wiring: Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed /blown insulation extends behind piping and wiring. (f) Comers, headers, narrow framing cavities, and rim joists are insulated. (9) Shower /tub on exterior wall: Insulation exists between showers /tubs and exterior wall. Sunrooms: • Sunrooms that are thermally isolated from the building envelope have a maximum fenestration U- factor of 0.50 and the maximum skylight U- factor of 0.75. New windows and doors separating the sunroom from conditioned space meet the building thermal envelope requirements. Materials Identification and Installation: D Materials and equipment are installed in accordance with the manufacturer's installation instructions. ▪ Insulation is installed in substantial contact with the surface being insulated and in a manner that achieves the rated R- value. u Materials and equipment are identified so that compliance can be determined. • Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. D Insulation R- values and glazing U- factors are clearly marked on the building plans or specifications. Duct Insulation: • Supply ducts in attics are insulated to a minimum of R -8. All other ducts in unconditioned spaces or outside the building envelope are insulated to at least R -6. Duct Construction and Testing: D Building framing cavities are not used as supply ducts. • All joints and seams of air ducts, air handlers, filter boxes, and building cavities used as return ducts are substantially airtight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Tapes, mastics, and fasteners are rated UL 181A or UL 181B and are labeled according to the duct construction. Metal duct connections with equipment and /or fittings are mechanically fastened. Crimp joints for round metal ducts have a contact lap of at least 1 1/2 inches and are fastened with a minimum of three equally spaced sheet -metal screws. Exceptions: Joint and seams covered with spray polyurethane foam. Where a partially inaccessible duct connection exists, mechanical fasteners can be equally spaced on the exposed portion of the joint so as to prevent a hinge effect. Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Li All ducts and air handlers are located within conditioned space. Heating and Cooling Equipment Sizing: ▪ Additional requirements for equipment sizing are included by an inspection for compliance with the International Residential Code. • For systems serving multiple dwelling units documentation has been submitted demonstrating compliance with 2009 IECC Commercial Building Mechanical and /or Service Water Heating (Sections 503 and 504). Circulating Service Hot Water Systems: ▪ Circulating service hot water pipes are insulated to R -2. • Circulating service hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the system is not in use. Heating and Cooling Piping Insulation: • HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R - 3. Swimming Pools: • Heated swimming pools have an on /off heater switch. • Pool heaters operating on natural gas or LPG have an electronic pilot light. • Timer switches on pool heaters and pumps are present. Exceptions: Where public health standards require continuous pump operation. Where pumps operate within solar- and /or waste- heat - recovery systems. ❑ Heated swimming pools have a cover on or at the water surface. For pools heated over 90 degrees F (32 degrees C) the cover has a minimum insulation value of R -12. Exceptions: Project Title: Von Goeler Slough Residence Report date: 09/07/11 Data filename: Untitled.rck Page 3 of 4 REScheck c t i on Software Version 4.4.1 Inspe Checkl Ceilings: ❑ Ceiling 2: Flat Ceiling or Scissor Truss Exemption: Framing cavity filled with insulation. Comments: ❑ Ceiling 1: Cathedral Ceiling (no attic), R -38.0 cavity + R -25.0 continuous insulation Comments: Above - Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c. Exemption: Framing cavity filled with insulation. Comments: ❑ Wall 2: Wood Frame, 16" o.c., R -18.1 cavity + R -25.0 continuous insulation Continuous insulation specified for this above -grade wall has consistent R -value rating across full area of the wall. Comments: Basement Walls: ❑ Basement Wall 1: Solid Concrete or Masonry, 9.0' ht / 7.5' bg / 8.0' insul, R -20.0 continuous insulation Comments: Windows: ❑ Window 1: Vinyl Frame:Triple Pane with Low -E, U- factor: 0.200 For windows without labeled U- factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1: Glass, U- factor: 0.250 Comments: Air Leakage: ❑ Joints (including rim joist junctions), attic access openings, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed with caulk, gasketed, weatherstripped or otherwise sealed with an air barrier material, suitable film or solid material. ❑ Air barrier and sealing exists on common walls between dwelling units, on exterior walls behind tubs /showers, and in openings between window /door jambs and framing. ❑ Wood - buming fireplaces have gasketed doors and outdoor combustion air. ❑ Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. ❑ Recessed lights in the building thermal envelope are 1) type IC rated and ASTM E283 labeled and 2) sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ Access doors separating conditioned from unconditioned space are weather- stripped and insulated (without insulation compression or damage) to at least the level of insulation on the surrounding surfaces. Where loose fill insulation exists, a baffle or retainer is installed to maintain insulation application. Air Sealing and Insulation: ❑ Building envelope air tightness and insulation installation complies by either 1) a post rough -in blower door test result of less than 7 ACH at 33.5 psf OR 2) the following items have been satisfied: (a) Air barriers and thermal barrier: Installed on outside of air - permeable insulation and breaks or joints in the air barrier are filled or repaired. (b) Ceiling /attic: Air barrier in any dropped ceiling /soffit is substantially aligned with insulation and any gaps are sealed. Project Title: Von Goeler Slough Residence Report date: 09/07/11 Data filename: Untitied.rck Page 2 of 4 r • • C REScheck Software Version 4.4.1 RECEIVED Compliance Certificate 3 0 201 DEPT. OF BUILDING INSPECTIONS NORTHAMPTON MA 01060 Project Title: Von Goeler Slough Residence Energy Code: 2009 IECC Location: Northampton, Massachusetts Construction Type: Single Family Project Type: Addition /Alteration Heating Degree Days: 6404 Climate Zone: 5 Construction Site: Owner /Agent: Designer /Contractor: 24 Hampden Street Northampton, MA 01060 Compliance: Passes Compliance: 41.4% Better Than Code Maximum UA: 232 Your UA: 136 The % Better or Worse Than Code index reflects how close to compliance the house is based on code trade -off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Gross Cavity Cont. Glazing UA Assembly Area or R- Value ` R -Value or Door Perimeter U- Factor Ceiling 2: Flat Ceiling or Scissor Truss -- - -- -_ -_ _ Exemption: Framing cavity filled with insulation. Ceiling 1: Cathedral Ceiling (no attic) 574 38.0 25.0 9 Wall 1: Wood Frame, 16" o.c. - -- - -- - -- - -- - -- Exemption: Framing cavity filled with insulation. Wall 2: Wood Frame, 16" o.c. 1026 18.1 25.0 18 Basement Wall 1: Solid Concrete or Masonry 1231 0.0 20.0 50 Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 8.0' Window 1: Vinyl Frame:Triple Pane with Low -E 242 0.200 48 Door 1: Glass 42 0.250 11 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.4.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Project Title: Von Goeler Slough Residence Report date: 09/07/11 Data filename: Untitled.rck Page 1 of 4 ;`, • Thp r'omiionwealth of Massachusetts RECEIVE « tm 'nt of Industrial Accidents Pk = Iriiii el ,, Office of Investigations ; v 1 4 =7 4, wool r SP 3 00 609 Washington Street -- 3oston, MA 02111 , wwwoa , wor,,in o,oso °" � vww.mass.gov /dia Workers' Compensation Insurance Affidavit: Builders / Contractors /Electricians/Plumbers Applicant Information Please Print Legibly _ Name ( Business /Organization/Individual): e N S/4 ' jf (// L7) STEVE Elk X 4 R Address: / )\Y M N R OA ' City /State /Zip: FI-0){ EP C E 1'1 at 0 /0 6a-- Phone #: y13 - 588 — Vi 7,5" Are you an employer? Check the appropriate box: Type of project (required): 1. El I am a employer with 4. ❑ I am a general contractor and I ___ smployees (full and /or part- time).* have hired the sub - contractors 6. ❑ New construction 2. V 1 am a sole proprietor or partner- listed on the attached sheet. 7. 1Kmodeling ship and have no employees These sub- contractors have 8. ❑ Demolition working ca employees and have workers' g for me in any capacity. y . 9. ❑ Building addition [No workers' comp. insurance comp. insurance. required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3. ❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, § 1(4), and we have no employees. [No workers' 13.0 Other comp. insurance required.] *Any applicant that checks box #1 must also fill out the section below showing their workers' compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. *Contractors that check this box must attached an additional sheet showing the name of the sub - contractors and state whether or not those entities have employees. If the sub - contractors have employees, they must provide their workers' comp. policy number. I am an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy # or Self -ins. Lic. #: Expiration Date: Job Site Address: City /State /Zip: Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and /or one -year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and enalties of perjury that the information provided above is true and correct. Si l nature: -MA ii4.1. I s Date: 9 a" 0 Phone #: y13 s'p8 — P 9 7 S Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit /License # Issuing Authority (circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone #: SECTION 8 - CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: '( Not Applicable ❑ Name of License Holder : > / & Y' C) FA ) I , d if -L- ` " g License Number 1 fy44 j l Ft- ENC6 clo 6.2, Add - Expiration Date A ire i wAt 1/) A --,ce s- V 7 7 S S'• atu Telephone 9. Registered Home Improvement Contractor: Not Applicable ❑ 'C/ <SMi+ 13 of L)) Nc- Company Name Registration Number &Y4' ;\b Address Expiration Date FLO C /lt" C/ 14 4 0I 6 vZ- Telephone 4 1/3 _,S$ SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes No ❑ 1. Home Owner Exemption The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature r • SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) New House ❑ Addition Replacement ndows Alteration(s) g Roofing Or Doors Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [E] Siding Other [0] Brief Description of Proposed / �� � ��� /�� Work: �G . i l /--4". L ' U r ' /C/N /1'2cz �� l <y( �'.Yt ir!-- / , r eb ',r (i - jr �'`� Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes bX Nok41A4/1/1.^1- Plans Attached Roll - Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family `X Two Family Other b. Number of rooms in each family unit: _ S Number of Bathrooms X c. Is there a garage attached? AO d. Proposed Square footage of new construction. Dimensions e. Number of stories? ,-- /' {.�, Y '� p f. Method of heating? Gtf 1 G t S'e tw414d Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? YE S h. Type of construction WO ° D rig q Al E" i. Is construction within 100 ft. of wetlands? Yes K No. Is construction within 100 yr. floodplain Yes kNo i j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? X Yes No . I. Septic Tank City Sewer K Private well City water Supply fk SECTION 7a - OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I Ni -'g-Ip4 k? �` y y S e: v i , as Owner of the subject property 6) hereby authorize to act my behalf, ' II matters relative to work authorized by this building permit application. Signature of Date 1, 57 !4 E» Ft-TA 14 A ►4 1 , as Owner /Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed unde he pains and penalties of perjury. Te effr7V FE A 8 4 RT Print Name Signature . 4iwn- ' Agent Date 44 Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size i3/ G 25 / i , J i c -L. g Frontage Setbacks Front n A / � ' ! Cr V Side L: I q , R: - $'� L: J , ,, R: S` C�R Rear Building Height -r m . Bldg. Square Footage + o Open Space Footage o7 (Lot area minus bldg & paved 1 S 9 i »_� !e parking) # of Parking Spaces e Fill: /d (volume & Location) r T A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO 0 DON'T KNOW 0 4,4 YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO (,) DONT KNOW 0 YES IF YES: enter Book Page and /or Document # B. Does the site contain a brook, body of water or wetlands? NO to® DON'T KNOW 0 YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES Q NO fik. IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO .., 40 w IF YES, then a Northampton Storm Water Management Permit from the DPW is required. Se! •_ Department use onty 4 -ty of Northampton Status cif Permit , , RECEIT wilding Department Curb�Cut/R�iyeway Permit 212 Main Street Sewer/Septic Availability SEP 3 0 Room 100 Water/ ell Availability hampton, MA 01060 Two Sets of StruoturaI. Plans • L OF BUILpINGINsp ' ,4 . 41 : 587 - 12 4 0 Fax 413 - 587 - 1272 Piot/Site Plans , 'AMPTO MA01i:, Other Specify' ' ; APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE INFORMATION 1.1 Property Address: t This section to be completed by office � � / )4 °'t; e L4 5 C Map Lot Unit P e 4 1 /e/ H r 1 c ', e 6 0 Zone Overlay District Elm St. District CB District SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: I v iZil GO deWN - fre4e 5/0 co 1- ..`1f /7 ��I� 5T �t0O>r14a r, j e27 d 4 Name ( tint) Current Mailing Ad s' "G (, t i,4•a Telephone Signature 2.2 Authorized Agent: t 1 P wr / - ✓` ea r ) r c� 3 A)-a .. t R� iF // I"e 4 eE, o c Na' - ' t Current Mailing Address: .ii 9 �� „„, A1.611 , iii L il3 s 9?• -f3 7 (atur: Telephone SECTION 3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building 2_50 000 A. (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of �� ��' 0 Construction from (6) 3. Plumbing c, S ©0 Building Permit Fee 4. Mechanical (HVAC) t 00 0 5. Fire Protection 6. Total = (1 + 2 + 3 + 4 + 5) -7 000.. ',') Check Number pzc j 3 This Section For Official Use Only Building Permit Number: Date Issued: Signature: Building Commissioner /Inspector of Buildings Date File # BP- 2012 -0326 Id , • ��� � D ti APPLICANT /CONTACT PERSON STEPHEN FERRARI ADDRESS/PHONE 103 RYAN RD FLORENCE (413) 588 -8975 0 K J 'D PROPERTY LOCATION 24 HAMPDEN ST f f l ` MAP 38D PARCEL 025 001 ZONE URB(100)/ pL- ' 0 kfV (E w THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out / Fee Paid �� Typeof Construction °.DON'T KNOW New Construction A _ ■ � L �, Non Structur. TERM / 1 Addition to E 7 1 " . Ili .4,��/Yr Accessory Structure Building Plans Included: 4 � Owner/ Statement or License 98877 3 sets of Plans / Plot Plan 4 /f THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF PRESENTED: Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management a - molition Delay ignature o kith . g • ficial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. 24 HAMPDEN ST BP -2012 -0326 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38D - 025 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: ADDITION BUILDING PERMIT Permit # BP- 2012 -0326 Project # JS- 2012- 000531 Est. Cost: $274000.00 Fee: $1644.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: STEPHEN FERRARI 98877 Lot Size(sq. ft.): 6882.48 Owner: SLOUGH KELLY & RUTH VON GOELER Zoning: URB(100)/ Applicant: STEPHEN FERRARI AT: 24 HAMPDEN ST Applicant Address: Phone: Insurance: 103 RYAN RD (413) 588 -8975 0 FLORENCEMA01062 ISSUED ON:11/2/2011 0:00:00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT 2 STORY ADDITION (MSTR BEDRM /LIVING RM & BASEMENT FAMILY ROOM, RENOVATIONS & DEEP ENERGY RETROFIT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 11/2/2011 0:00:00 $1644.00 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner !i