Loading...
17D-088 b. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 c. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 3/4" from the top of the threshold and only in- swinging doors. 780 CMR R311.3 13. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ", maximum riser 8 % ", maximum overall variance for the run is 3/8 ", 4" sphere rule on risers, 4 3/8" on balustrade, 6" in the triangle. Graspable rail 1 %" minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 14. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36 ", 4" sphere rule. See 780 CMR R312.1. 15. Educate the plumber and electrician about maximum notch and hole sizes, and placement. See 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In interior non - bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1 %2 16ga. strap must extend a minimum of 6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom. Notches are different. 16. Fire and draft stopping shall be completed before rough inspection. See 780 CMR R302. 17. Ignition barriers in place before final. See 780 CMR R316. 18. Energy aspects shall comply with energy code. See 780 CMR and 2009 IECC. a. Energy information including mechanical equipment posted on the electric panel. 19. Deck ledgers and post must be appropriately attached. Note: ThruLoks are engineered for post attachment supporting a railing. See 780 CMR R502.2.2.1 20. Smoke and CO detectors as required. See 780 CMR R314 and R315. Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. My email address is: cmiller Thankyqu for AI ur cooperation on these matters. Chuck MI ler City of Northampton Assistant Commissioner and Zoning Enforcement cmillerna northamptonma.gov • City of Northampton Massachusetts * _�� IT- DEPARTMENT OF BUILDING INSPECTIONS �- 212 Main Street • Municipal Building Northampton, MA 01060 INSPECTOR Larry Rideout 1209 Springfield Street Feeding Hills 01030 October 19, 2011 Subject Location: 111 Straw Avenue Map Block: 17D - 088 Mr. Rideout Your electronic plans dated 9 -08 -11 have been approved as noted. 1. Smokes and Cos per code and fire department. 2. Energy criteria must meet the stretch code requirements. 3. Engineering data for all non prescriptive materials. As of August 4 2011 the 8th Addition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8 addition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. See 780 CMR R401.3 for drainage requirements. 3. Where ceiling joist are not directly connected to the rafters, rafter ties are required. See 780 CMR R802.3.1. Minimum 2x4 16" OC nailed per 780 CMR Table R802.5.1(9) 4" slope 8 -16nd common at each connection. 4. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1 /3 780 CMR R802.3.1 5. Ridge boards must be the full depth of the cut 780 CMR R802.3. 6. A complete window and header schedule is required. See 780 CMR Table R502.5 for header sizing and number of jack studs required. 7. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss 8. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. See 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 9. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basement without habitable space, 6'4" at beams /ducts. 780 CMR R305.1. 10. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. See 780 CMR R308.4 11. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. See 780 CMR R612.2 12. Egress and emergency escape requirements shall be strictly met. a. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft at 15t floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 • • Bk: 10194 Pg: 81 Planning - Decision City of Northampton Hearing No.: PLN -2010 -0029 Date: April 8, 2010 (5) The requested use meets any special regulations set forth in this chapter (6.3 -B)= (1) The new dimensional requirements must be at least as stringent as the median of that dimension for al! lots where any portion of those lots Is within 300 feet of the subject parcel and within the same zoning district as the subject parcel; and (2) The requested special permit will provide inn!! development, and (3) A list of all applicable dimensional measurements for lots within 300 was filed with the special permit application as described in the Planning Board's bylaws; and. Complies with other criteria for zero lot line lots. • (6) The requested use bears a positive relationship to the public convenience or welfare. The use will not unduly impair the Integrity of character of the district or adjoining zones, nor be detrimental to the health, morals, or general welfare. The use shall be in harmony with the general purpose and intent of the ordinance; and (7) If applicable, the requested use will promote City planning objectives to the extent possible and will not adversely affect those objectives, as defined in City master or study plans adopted under MGL c. 41, § 81C and 81D. The plan calls for creation of a mix of residential types and infil! within this portion of the city. COULD NOT DEROGATE BECAUSE: FILING DEADLINE: MAILING DATE: HEARING CONTINUED DATE: DECISION DRAFT BY: APPEAL DATE 3/4/2010 3/18/2010 4/8/2010 REFERRALS IN DATE' HEARING DEADLINE DATE: HEARING CLOSE DATE FINAL SIGNING BY: APPEAL DEADLINE: 3/11/ 2010 5/9/2010 3/25/2010 4/8/2010 4/28/2010 FIRST ADVERTISING DATE: HEARING DATE: VOTING DATE: DECISION DATE: 3/11/2010 3/25/2010 3/25/2010 4/8/2010 SECOND ADVERTISING DATE, HEARING TIME: VOTING DEADLINE: DECISION DEADLINE: 3/18/2010 9:15 PM 6/23/2010 6/23/2010 MEMBERS PRESENT: VOTE: Marilyn Richards votes to Grant D [ II V_ Q ' Katharine G. Baker votes to Grant L! Stephen Gilson votes to Gran APR - 8 2010 ,..J Mark Sullivan votes to Grant ., Francis Johnson votes to Grant CITY CLERKS OFFICE George Kohout votes to Grant NORTHAMPTON, MA 01060 MOTION MADE 8Y: SECONDED BY: VOTE COUNT: DECISION: Mark Sullivan Francis Johnson 6 Approved with Conditions MINUTES OF MEETING: Available In the Office of Planning 8 Development. 1, Carolyn Misch, as agent to the Planning Board, certify that this is a true and accurate decision made by the Planning Board and certify that a copy of this and all plans have been filed with the Board and the City Clerk on the date shown above. 1 ce • that a copy of t • de� has been mailed to the Owner and Applicant Notice of Appeal An appeal from the decision of the Planning Board may be made by any person aggrieved pursuant to MGL Chapt 40A, Section 17 as amended within twenty (20) days after the date of the filing of the notice of the decision with the City Clerk. The date is listed above. Such appeal may be made to the Hampshire Superior Court with a certified copy of the appeal sent to the City Clerk of the City of Northampton. April 29, 2010 I, Wendy Mazza, City Clerk of the City of Northampton, hereby certify that the above Decision of the Northampton Planning Board was filed in the Office of the City Clerk on April 8, 2010 that twenty days have elapsed since such filing and tha no appeal has been filed on this matter Attest: 1 _� ��� . City Clerk / d City of Northampton GeoTMS® 2010 Des Lauriers Municipal Solutions, Inc. A'J &T: HAMPSHIRE, ✓ V t k , Hl4Cl T8'!'BR MARIANNE L. DONOVIE -~~- - • • Bk: 10194 Pg: 80 EC ENED Planning - Decision City of Northampton SEP 2 02011 Hearing No.: PLN- 2010 -0029 Date: April 8, 2010 & T. OF BUILDING INSPECTIONS APPLICATION TYPE: SUBMISSION DATE: NORTHAMPTON MA 01060 PB Special Permit with intermediate 3/5/2010 N APP 4 !1 �+ licant s Name: Owners Name: � NAME: I 1 I.11 , Q. GREENFIELDS INC GREENFIELDS INC Au ADDRESS: ADDRESS: Bk: 10194Pg: 80 Page: 1 of 2 P 0 BOX 11 P 0 BOX 11 Recorded: 08/04/2010 11:18 AM IA. N TOWN: STATE: ZIP CODE: TOWN: STATE: ZIP CODE: N e' LUDLOW MA 01056 LUDLOW MA , 01056 = PHONE NO.: F AX NO: PHONE NO.: FAX NO: ' 03 (413) 547 - 8988 p (413) 547 - 8988 0 EMAIL ADDRESS: EMAIL ADDRESS: Site information: Surveyor's Name: STREET NO.: SITE ZONING: COMPANY NAME: 117 STRAW AVE URB(100)/ TOWN: ACTION TAKEN: ADDRESS: FLORENCE MA 01062 Approved With Conditions MAP: BLOCK: LOT: MAP DATE: SECTION OF BYLAW: 17D 019 001 Chpt. 350 -6.3: Reduction of Dimensional TOWN: STATE ZIP CODE: Book: Page: and Density Regulations _ 9836 1 221 PHONE NO.: FAX NO.: EMAIL ADDRESS: NATURE OF PROPOSED WORK: Frontage reduction through dimensional averaging, HARDSHIP: CONDITION OF APPROVAL: 1) Two shade trees of 3' caliper upon planting shall be planted along the frontage between the new driveway and the southern property boundary. The species shall be selected by the applicant from the Northampton Tree Committee approved list of street trees . These trees shall be maintained in perpetuity and If necessary replaced if damaged. 2. The existing shade tree along the street frontage in front of the existing house shall be maintained. 3. The sidewalk along the street frontage shall be repaired and if It is necessary be replaced with cement concrete in accordance with DPW sidewalk construction standards. 4. As offered by the applicant and prior to the issuance of a certificate of occupancy, a payment of $1,000 shall be made to mitigate traffic Impacts for the new unit. FINDINGS: The Planning Board approved the application for a special permit for frontage reduction for a zero lot line single family home for the existing single family home as well as the new single family home based on the plans submitted with the application. The single family house lot frontage was reduced from 65' to 62' and the new single family house lot was reduced from 65" to 62 ". In granting the permit, the Board found that the following required elements had been met: (1) The requested use protects adjoining premises against seriously detrimental uses in relation to surface water drainage, sound and sight buffers and preservation of views, light and air; The proposed is a single family unit on a lot within a neighborhood that contains a mix of lot sizes and densities close to downtown Florence. (2) The requested use will promote the convenience and safety of vehicular and pedestrian movement within the site and on adjacent streets, minimize traffic impacts on the streets and roads in the area. if applicable, this shall include considering the location of driveway openings In relation to traffic and adjacent streets, access by emergency vehicles, the arrangement of parking and loading spaces, and provisions for persons with disabilities; and. Single family home would not significantly add to traffic concerns. The applicant has offered to make a payment in -lieu of worth ;1,000 to meet the mitigation. (3) The requested use will promote a harmonious relationship of structures and open spaces to the natural landscape, existing buildings and other community assets in the area; The total lot area will remain conforming and (4) The requested use will not overload, and will mitigate adverse impacts on, the City's resources including the effect on the City's water supply and distribution system, sanitary and storm sewage collection and treatment systems, fire protection, streets and schools. There is capacity In the system; and GeoTMS® 2010 Des Lauriers Municipal Solutions, Inc. • File # MP- 2010 -0039 APPLICANT /CONTACT PERSON PIETRAS MICHAEL ADDRESS/PHONE P 0 BOX 11 (413) 547 -8988 0 PROPERTY LOCATION 117 STRAW AVE MAP 17D PARCEL 019 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ONING FORM " ILLED OUT - e Building Permit Filled out Fee Paid Typeof Construction: ZPA - DIVIDE PARCEL New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER : § Intermediate Project : Site Plan AND /OR Special Permit with Site Plan Major Project: Site Plan AND /OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed LS Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of Planning & Development for more information. • • • • • NO wAN O I•M MINIM 1 GUM i \ VI NM aukMAL MA 1.. MAN i VERONA STREET $'Inver a av _ ei ■ J . 1 1 PARSE! Z. wa"�.rMS A wfA r NOilla I2 q R. am:. ruw�iar arkwou KW PUP MAO KAI r • ' Mir , Iraq i - —cidieiritzeiii— ! USW M I PARCF1 ar ...noel. I2 a0. R. fik 1a uu • N A a "Tarr � M y N • � • Q �r MINIS • /ON• 111111111111111, 111111111111111, 111111111111111, • •011 RAN ILO NM OOti t 1NN mr 11. 10. MAI AK •111114111 L A a l• UUN4 /Mall 111/11•111 *AMA M lit N IN DIMI N• N1111 1110 • A f w OM ° SUBDI SION APPROVAL NOT REQUIRED" IN 1R NM /I• Aa1vII�a• a 11S IMAM aaw PLAN OF LAND OIuNM�I __ t W:NE 1112 %V AMP FLORENCE ONORIHAMPT�ON), MA • NOT 110111® GREEN MELDS INC. NORTH*PTON PLANNING BOARD PARCEL 170-019 . ON IC IINNUMIN 2% !01O !CALL 1' • PALS. S. SUM LAW SURVEYING Le ar .o' le XS IIW NOM LMT LOM tADOR NA — 11111 — - - _ (4131 ��)� 025.-4700 / ti • ' MUNICIPAL SEWER/ AVAILABILITY APPLICATION Northampton Streets Department 125 Locust Street Northampton, MA 01060 587 -1570 A Department of Public Works Trench Permit and Sewer Entry Permit shall be required prior to any construction or connection activity associated with this application. Location: 111 Straw Avenue, Florence Inquiry Made By: Larry Rideout/Rideout Builders 413- 885 -2876 Date of Inquiry: 9/9/11 • Reason for Hook new construction into City Sewer Service Request: Municipal Sewer Main in Front of Location: Yes No Municipal Storm Drain Available: 5 '/2 deep Yes No Age: A Size of Sewer Main: 1 Material: � L AV g � ,23 Depth of Sewer Main: — 5 f' Size of Service Connection: rJ / Al c • Type of Service Connection: Tie -in to Sanitary Main Tie -in to Sanitary Stub Comments: Note: If this availibilitv is for new construction, this form must be hand delivered to Building Inspector. A corresponding "sewer entrance fee" shall be paid prior to making any connection to the municipal sewer system. Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department specifications. John Hall Sewer Department cc: Ned Huntley, Director DPW Louis Hasbrouck, Building Commissioner 5oo- • • • MUNICIPAL WATER AVAILABILITY APPLICATION Northampton Water Department 237 Prospect St. Northampton, MA 01060 587 -1097 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: 111 Straw Avenue, Florence Inquiry Made By: Larry Rideout/Rideout Builders 413 - 885 -2876 Date of Inquiry: 9/9/11 Number of Type of Single Family Type of Private Units: Unit(s): Accessory Apart. Ownership: Condo Multi- family Rental (Applicant to fill out the above) Municipal Water Main in Existing service to Front of Location? Yes: X No: site? Yes: No X Size of Water Main: 6" Material: Cast Iron Age: 1927 Approximate Static Street Flow Test Conducted: Yes: No: Pressure: 75 If done attach results Size of Service Connection 1" Suggested Meter Size: 5/8" Comments: The Water Department cannot guarantee adequate water pressure during peak demand times at elevations above 320 feet. • A corresponding water entrance fee shall be paid prior to making any connection to the municipal water system. • ange ents of such i I : at s n shall be made with the Northampton Water Depai intent with a minimum of 5 w ing day .tificati • All ork hall o' i rtham on Water Department specifications. r 1 David W. Sparks, Superintendent of Water Water Entry $200.00 Meter $100.00 Radio $100.00 cc: Ned Huntley, Director cc: Louis Hasbrouck, Building Commissioner Note: If this availability is for a new construction it must be hand delivered to the Building Inspector. e1 TKA}1p 2q . o ya s:L� 'y; 4Qi yts DEPARTMENT OF BUILDING - INSPECTIONS °�' ,INSPECTOR 212 Main Street 0 .Municipal Bunking z7 Northampton, MA 01060 • All LOCATION / A.l,,,!: ,- SQUARE FOOTAGE AMOUNT BASEMENT @ :..20 ©O 0 / a v 1 @ .50 1 1 30 2 FL.R @ 30' - ‘ 13 0 0 / 0 % FLOORS, FINISH ATTIC, GARAGE @ .20 3 3. 0 " Y • DECK/PORCHES @ :20 C X 0 TOTAL. F..?.0 . • , . . . • . . ________.__.. . _.. __________. _____._ .... . PENDING APPROVAL 111 STRAW AVENUE CITY OF NORTHAMPTON Permit No. 6456 .. DEPARTMENT OF PUBLIC WORKS DISAPPROVED ` 125 Locust Street Date Issued 9/15/2011 m ' ' ' ' Northampton, MA 01060 By a �;t Phone 413 -587 -1570 (Department of Public Works) c?. FAX 413 - 587 1576 No work to start until signed TRENCH PERMIT Pursuant to G.L. c. 82A § 1 and 520 CMR 7.00 et seq. (as amended) THIS PERMIT MUST BE FULLY COMPLETED PRIOR TO CONSIDERATION This permit (License for excavating on any public way and private property) is issued under the provisions of M.G.L. c. 82A § 1 and 520 CMR 14.00 and Section 285 -21 of the Revised Ordinances of the City of Northampton subject to the "Specifications for Care of Street Cuts" approved and adopted by the Department of Public Works on September 21, 1991. The applicant hereby agrees to protect all cuts with barricades and lights, and to save the City of Northampton harmless from all claims for damages whatsoever arising from the occupation of all properties affected by this permit, until such time as the work has been approved and accepted by the Department of Public Works as provided for below, and in the case of private utility, to pay all charges for resurfacing. Fee: $250.00 Check # 1122 Valid for 30 days from date of approval. Expiration Date: Name of Applicant Phone Cell JACQUES CONSTRUCTION, INC. 413 -539 -9331 JOHN ST J _ Street..Address_- 2 INDUSTRIAL DRIVE City/Town STATE ZIP • SOUTHHADLEY MA 01075 Name of Excavator (if different from applicant) Phone Cell SAME Street Address City/Town STATE ZIP Name of Owner(s) of Property Phone Cell LARRY RIDEOUT 413 -885 -2876 Street Address City/Town STATE ZIP Location of proposed trench: 111 STRAW AVENUE Description and purpose of proposed trench: please describe the exact location of the proposed trench and its purpose. Include a description of what is (or is intended) to be laid in proposed trench (eg; pipes /cable lines etc...) NEW CONSTRUCTION HOOK INTO WATER, SEWER, DRIVEWAY INSTALLATION Estimated dates of occupation of street: PENDING APPROVAL Insurance Certificate #: ON FILE Name and Contact Information of Insurer: ON FILE Policy Expiration Date: ON FILE . Dig Safe #: . 2011 -380 -1379 ALL PERMITS ISSUED PURSUANT TO 520 CMR 14.00 SHALL BE POSTED IN PLAIN VIEW ON THE SITE OF THE TRENCH Note- Contractors will be charged for Inspections requested outside of regular working hours (7:00 a.m. - 3:00 p.m. M -F) Contractor to notify DPW when job is in progress. NOTE: Engineers need ties to this service for our records. TEMPORARY INFRA -RED SHALL BE REQUIRED AF 1'1.R TRENCH CUT IS MADE PATCH REQUIRED 1/0 0 ,F —1)-----' D oq-0-- so-/-- . . . Contractor: Rideout Builders Larry Rideout CSL 11635 HIC 129465 1209 Springfield St. Feeding Hills, Ma. 01030 Tel. 413 -585 -2876 Sub- Contractor List for 111 Straw Avenue Residence Construction. Mechanical and Plumbing — M.J. Moran Inc. 4 South Main St. P.O. Box 278 Haydenville MA 01039 Electrical- Blanchard & Daly Electric Inc. P.O. 413 Southampton, MA 01073 Excavation - Jaques Construction, Inc. 2 Industrial Drive S. Hadley, MA 01075 Roofing- A&J Home Improvement -60 Washington Ave, South Hadley, MA 01075 Framing- Landry Construction, 116 Burnett St., Granby, MA. 01033 Concrete- Western Mass Concrete Service Inc. 46 East Carew St Unit 7 S. Hadley, MA 01075 ENERGY STAR VERSION 2.5 HOME VERIFICATION SUMMARY Date: September 02, 2011 Rating No.: Property: 111 Straw Ave. Rating Org.: Center for EcoTechnology Northampton, MA Rater's Name: Josy Raycroft Builder's Name: Larry Rideout Rater's ID: 8272678 Building Name: 111 Straw Ave. Rating Date: 9/1/11 Building Information Ratings Conditioned Area (sq ft): 2016 HERS Index: 51 Conditioned Volume (cubic ft): 18648 HERS Index w/o PV: 51 Insulated Shell Area (sq ft): 5228 HERS Index Target (SAF Adjusted): 70 Number of Bedrooms: 3 HERS Index of Reference Design Home: 70 Housing Type: Single- family detached Size Adjustment Factor: 1.00 Foundation Type: More than one type Building Shell Ceiling w /Attic: None Window/Wall Ratio: 0.18 Vaulted Ceiling: R41,CE,10- 16, +7,C U =0.023 Window Type: U:0.29, SHGC:0.28 Above Grade Walls: R19,CE1,6- 16, +7.5 U =0.040 Window U- Value: 0.290 Found. Walls (Cond): R71 R =7.0 Window SHGC: 0.280 Found. Walls (Uncond): None Infiltration: Htg: 2.50 Clg: 2.50 ACHSO Frame Floors: None Measured Duct Leakage: 0.00 CFM25 Slab Floors: R7.5P,R1OU,24W U =0.049 Leakage to Outside: 0.00 CFM Mechanical Systems Heating: Fuel -fired hydronic distribution, 39.0 kBtuh, 93.0 AFUE. Water Heating: Integrated, Gas, 0.85 EF. Programmable Thermostat: Heat =No; Cool =No Ventilation System: Balanced: ERV, 50 cfm, 121.0 watts. Note: Where feature level varies in home, the dominant value is shown. This home MEETS OR EXCEEDS the EPA's requirements for an ENERGY STAR Home. HERS Index w/o PV <= HERS Index of Reference Design Home AND HERS Index <= HERS Index Target to comply. REM /Rate - Residential Energy Analysis and Rating Software v12.93 This information does not constitute any warranty of energy cost or savings. © 1985 -2011 Architectural Energy Corporation, Boulder, Colorado. • • SECTION 8 - CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder : S c— IP (1 O /off License Number 0 N. I �� r�eec) 1-1( Cs /r6 3 -3 Address Expiration Date Signatur Telephone F 9C/ Fs ..'76 9. Registered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number Address Expiration Date Telephone SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes C No ❑ 11. - Home Owner Exemption The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two - year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature I WORKERS' COMPENSATION AND EMPLOYERS LIABILITY INSURANCE POLICY Information Page WC 00 00 01 Atlantic Charter Insurance Company VDAC NCCI Co. No.: 29211 Policy Number: WCV00859401 1. INSURED: Prior Policy Number: WCV00859400 Larry Rideout Producer: 1209 Springfield Street James J. Dowd & Sons Insurance Agency, Inc. Federal ID Number:203749046 Feeding Hills, MA 01030 Risk ID Number: PO Box 10300 Holyoke, MA 01041 Business Type. Individual SIC:9999 NONCLASSIFIABLE ESTABLISHMENTS Other Named Insured: See WCE106 Other Work Places: See WCE107 2. POLICY PERIOD: The Policy Period Is From: 10/15/2010 To 10/15/2011 12:01 A.M. Standard Time at The Insured Mailing Address 3. COVERAGES: A. Workers Compensation Insurance: Part One of the policy applies to the Workers Compensation Law of the states listed here: MA B. Employers Liability Insurance: Part Two of the policy applies to work in each state listed in item 3A. The limits of our liability under Part Two are: Bodily Injury by Accident $ 100,000 each accident Bodily Injury by Disease $ 500,000 policy limit Bodily Injury by Disease $ 100,000 each employee C. Other States Insured: Part Three of the policy applies to the states, if any, listed here: COVERAGE REPLACED BY ENDORSEMENT WC 20 03 06A All states except Monopolistic State Fund States D. This policy includes these endorsements and schedules: See WCE105 4. COVERAGES: The premium for this policy will be determined by our Manual of Rules, Classifications, Rates & Rating Plans. All information required below is subject to verification and change by audit. Code Premium Basis Total Rate Per Estimated Classifications Estimated Annual $100 of Annual No. Remuneration Remuneration Premium See WC 00 00 01 Minimum Premium: Deposit Premium: 1$500 $500 Interim Adjustment: Annually Servicing Office: Estimated Premium (Minimum Premium) $500 25 New Chardon Street Boston, MA 02114 -4721 / / Issue Date 10/05/2010 Countersigned By: Copyright 1987 National Council on Compensation Insurance Form 100m w The Commonwealth of Massachusetts Department of Industrial Accidents r # - _ Office of Investigations 600 Washington Street Boston, MA 02111 ° www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders / Contractors /Electricians/Plumbers Applicant Information Please Print Legibly Name ( Business /Organization/Individual): _ e 1T .0 [? A t --- t.,11/ 1') ( l Address: lc? © 9 k) C 19 ELD S T i City /State /Zip: I" ei Dt tt/ ' -4114 M 1/- Oio ♦' hone #: / / 3 5 ' 7,6 Are you an employer? Check the appropriate box: Type of project (required): 1. ❑ I am a employer with 4. XI am a general contractor and I employees (full and/or part-time).* have hired the sub - contractors 6. New construction listed on the attached sheet. 7. ❑Remodeling 2. El I am a sole proprietor or partner- ship and have no employees These sub - contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑Building addition [No workers' comp. insurance comp. insurance.: required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3. ❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12. ❑ Roof repairs insurance required.] t c. 152, § 1(4), and we have no employees. [No workers' 13. ❑ Other comp. insurance required.] *Any applicant that checks box #1 must also fill out the section below showing their workers' compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. 1 Contractors that check this box must attached an additional sheet showing the name of the sub - contractors and state whether or not those entities have employees. If the sub - contractors have employees, they must provide their workers' comp. policy number. I am an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: /4T iv77 C C./f4R RP e4c- - ) ntlici ('c6 Policy # or Self -ins. Lic. #: WC cag3 ' c / Expiration Date: /0 / I5 /X / / Job Site Address: 1 / 1 5T/Qi1 C) FL4/c04 City /State /Zip: m /9- Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one -year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjug that the information provided above is true and correct. Signature: Date: , /2 C / Phone 7.6 Official use only. Do not write in this area, to be completed by city or town official City or Town: Permit/License # Issuing Authority (circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone #: Y ' ' ` i • 4 i 1 • • • • . Y • SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) New House In Addition ❑ Replacement Windows Alteration(s) I I Roofing ❑ Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [Q Siding [0] Other [o] Brief Description of Proposed Work: 17 hl (s* L. E t rid ' 3 BE PgooM geSiaeWce Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll - Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family !t Two Family Other b. Number of rooms in each family unit: 7 Number of Bathrooms 2 y 2 c. Is there a garage attached? Cte5 � t x d. Proposed Square footage of new construction. l D 10 S f Dimensions p �' e. Number of stories? I `/ Z. /AMT. 645 f Soc-M 1 S. Al f. Method of heating? 13A6E. Q j7. 144'1 ill We' rt. Fireplaces or Woodstoves 1 Number of each '5"17X. g. Energy Conservation Compliance: Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes x No. Is construction within 100 yr. floodplain Yes )c No A ` j. Depth of basement or cellar floor below finished grade / k. Will building conform to the Building and Zoning regulations? A Yes No . I. Septic Tank City Sewer X Private well City water Supply A SECTION 7a - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 'r i, DAL) t ol ` r „ , as Owner of the subject property - ,,���,,,,,JJJJJ hereby authorize c9 1."cd M i . t iv ('e I A u I I) to act on my ehalf, in all matte relae t work authorized by this building permit application. X * CLL cuvi i • L-(, 7 2‘) 0 Signature of wner Date I, L i-'"(; M i 1, l , as Owner /Authorized 1 Lin r that th statements and information on tFteor� going application are true and accurate, to the best of my knowledge Agent hereby declare 9 9 PP Y e 9 and belief. Signed under the pains d penalties of perjury. I, /A kv. Print Name � ( M CI ( ' P (( � ( - zD 1 X J �-'Y `l ,p T I Signature of Owner /Agent Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size I G go SF 1. 5 � Frontage 2 t Setbacks Front 'La' 20 t ! r f Side L: 7 R: �� L: R: Rear 40 2 0 Building Height )(21-518 Bldg. Square Footage j33 o I r Open Space Footage 1 Z1 S2 rOi (Lot area minus bldg & paved 17 parking) # of Parking Spaces 2: Fill: (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO 0 DON'T KNOW 0 YES IF YES, date issued: 4-1. g , 2416 IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW 0 YES 0 IF YES: enter Book 2- Page eCj and /or Document # B. Does the site contain a brook, body of water or wetlands? NO ® DON'T KNOW 0 YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained ® Obtained ® , Date Issued: C. Do any signs exist on the property? YES Q NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES ® NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. .r. • • • a ■ f r‘ • • +' • • • 11 •,. • • • - __..r-T=1r � , ` u City of Northampton &#. „ 2 4i1 Building Department II fie Ii 2. 0 212 Main Street t Room 100 ny ti'" o ,,. , Northampton, MA 01060 ." phone 413 -587 -1240 Fax 413 -587 -1272 p APP LICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELUNG SECTION 1 - SITE INFORMATION 1.1 Property Address: This section to be completed office 111 5 1 Aw A'e Map 17 P Lot Unit FL o ReN ce, M q Zone ()Re (100) Overlay District aIo(ot. Elm St. District CB District SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: Ol 065 VAN/1V FAYTeLl f 9AHI pees Fa JI 21 144ssQisoil i iJ•6,lt,piotf,M4. Name (Print) / �: Current Mailing Address : ^ 2 ,,,,, , 61 GL Vo ' • ie Telephone Signature 7 2.2 Authorized Agent: Simrt.d MAC,' gill IV (2q 0 Sowrti E-451 Sf N (punt) �// Current Mailing Address: �4 -MHeQs r- / r l r f f en oO- pi ( �' Ile l�— 113'54i 9 2 00 ? (ogf '.4.) Signature Telephone SECTION 3 - ESTIMATED CONSTRUCTION COSTS I Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building g Z75, oac ^ (a) Building Permit Fee 2. Electrical g 30 Q el O — (b) Estimated Total from 6 of 3. Plumbing hr ,2 01 O 60 Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 7 � C 6. Total = (1 + 3 + 4 + 5) i �j SO / 0 0 d Check Number / /G / if 96 U / ��( ' / his Section For Official Use Only d Building Permit Number: / Y(/ I Signature: Building Commissioner /Inspector of Buildings • pate „ ,. eLfoi • .) File # BP- 2012 -0280 G j APPLICANT /CONTACT PERSON LARRY RIDEOUT ADDRESS/PHONE 1209 SPRINGFIELD ST FEEDING HILLS (413) 885 -2876 Fe ! Ly PROPERTY LOCATION 111 STRAW AVE CSI 'VI ' ” ° tj3_C MAP 17D PARCEL 088 001 ZONE URB THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT n Fee Paid D ( SS ki C7 Building Permit Filled out J (�(^ � Coo Fee Paid ` f �,j `✓� 6 �� Typeof Construction: CONSTRUCT 1 1/2 STORY SFH W /ATT GARAGE /DECK � ` G New Construction Non Structural interior renovations P LI p ` -7 Addition to Existing Accessory Structure Building Plans Included: ` " Owner/ Statement or License 11635 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED O INF ATION PRESENTED: 11� �� 454.7._ �. A pproved Additional permits required (see below) ` / 1 .,, /� r o l ■ l PLANNING BOARD PERMIT REQUIRED UNDER:§ r Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management ee 1• 4# A O / ? - - / W S : .ture of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. .e 762/2-g' ' � 111 STRAW AVE BP- 2012 -0280 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 17D - 088 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: New Single Family House BUILDING PERMIT Permit # BP- 2012 -0280 Project # JS- 2012- 000448 Est. Cost: $350000.00 Fee: $960.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: LARRY RIDEOUT 11635 Lot Size(sq. ft.): Owner: FAYTELL DAVID & DANI Zoning: URB Applicant: LARRY RIDEOUT AT: 111 STRAW AVE Applicant Address: Phone: Insurance: 1209 SPRINGFIELD ST (413) 885 -2876 WC FEEDING H I LLSMA01030 ISSUED ON:10/24/2011 0:00:00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT 1 1/2 STORY SFH W /ATT GARAGE /DECK POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 10/24/2011 0:00:00 $960.00 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner • ?5