SOV CONDOR ROOF 24090806BR-Condo Project-R-R.K. Miles-Hatfield Quote-093024 SELL roofOVERHANG INFO HEEL HEIGHT
GABLE STUDS
00-00-00
24 IN. OC
END CUT RETURN
PLUMB
REQ. ENGINEERING
JOBSITE
REQ. LAYOUTS
JOBSITE 1 1
QUOTE
LAYOUT
CUTTING
GG1
GG1
DATEBY
SHIP
TO
24 West St
Hatfield, MA 01038
R.K. Miles-HatfieldSOLD
TO (413) 247-8300
SALES REP
ORDER DATE
REQ. QUOTE DATE
DELIVERY DATE
/ /
/ /
09/26/24 ORDER #
QUOTE #
TERMS
SALES AREA
CUSTOMER PO #
CUSTOMER ACCT #
INVOICE #
LMCWRKMI
ORDERED BY
SUPERINTENDENT
JOBSITE PHONE #
DATE OF INVOICE
24090806BR
Tyler Pohl
Massachusetts /
/ /
Ryan Thompson
(413) 247-8300
PAGE 1
SPECIAL INSTRUCTIONS:
DELIVERY INSTRUCTIONS:
JOB NAME:
MODEL: TAG:Roof Trusses
Condo Project-R
BUILDING DEPARTMENT
Roof Trusses
JOB CATEGORY:Single Family Custom
LOT # SUBDIV:
DATE09/30/24
152-154 South Main Street
Northhampton, MA 01062
Ryan Thompson
09/30/24
09/30/24
/ /
DESIGNER Gerson Garcia
QTY TYPE
SPAN LUMBER
TOP BOT
OVERHANG
LEFT RIGHT
CANTILEVER
LEFT RIGHT
PITCH
TOP BOT
ID
TOTALPRICEPRICEUNITPROFILE
ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL
35.0,10.0,0.0,10.0
STRESS INCR.
1.00INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.)ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL
35.0,10.0,0.0,10.0
STRESS INCR.
INFORMATION
PLY LEFT RIGHT
STUBO/ABASE
SPAN
G01
2
8.00 0.00 24-04-00 04-04-002 X 4 2 X 10
COMMON
2 Ply 24-04-00
G02
2
5.00 0.00 50-00-00 01-00-002 X 6 2 X 6
COMMON
2 Ply 50-00-00
G03
2
5.00 0.00 50-00-00 01-00-002 X 6 2 X 6
COMMON
2 Ply 50-00-00
G04
4
5.00 0.00 50-00-00 01-00-00 01-00-002 X 6 2 X 6
COMMON
2 Ply 50-00-00
J01 5.00 0.00 04-10-09 01-00-002 X 4 2 X 4
JACK-CLOSED
4 04-10-09
T01 5.00 0.00 50-00-00 01-00-002 X 6 2 X 6
COMMON
16 50-00-00
T010 8.00 0.00 24-04-00 04-04-0001-00-00 01-00-002 X 4 2 X 4
COMMON
2 24-04-00
T01G 5.00 0.00 50-00-00 01-00-002 X 6 2 X 6
COMMON
2 50-00-00
T02 5.00 0.00 50-00-00 01-00-002 X 6 2 X 6
COMMON
2 50-00-00
T02G 8.00 0.00 20-00-00 01-00-00 01-00-002 X 4 2 X 4
COMMON
2 20-00-00
T03 5.00 0.00 50-00-00 01-00-00 01-00-002 X 6 2 X 6
COMMON
8 50-00-00
T05 8.00 0.00 24-04-00 01-00-00 01-00-002 X 4 2 X 4
COMMON
2 24-04-00
T06 0.00 0.00 03-03-08 2 X 4 2 X 6
FLAT GIRDER
4 03-03-08
T07
4
0.00 0.00 03-03-08 2 X 6 2 X 6
FLAT GIRDER
2 Ply 03-03-08
T08 5.00 0.00 35-07-13 2 X 4 2 X 4
COMMON
2 14-04-0350-00-00
T09 5.00 0.00 35-07-13 01-00-002 X 4 2 X 4
COMMON
2 14-04-0350-00-00
V01 8.00 0.00 22-08-02 2 X 4 2 X 4
VALLEY
2 22-08-02
V02 8.00 0.00 20-02-02 2 X 4 2 X 4
VALLEY
2 20-02-02
V03 8.00 0.00 17-08-02 2 X 4 2 X 4
VALLEY
2 17-08-02
V04 8.00 0.00 15-02-02 2 X 4 2 X 4
VALLEY
2 15-02-02
OVERHANG INFO HEEL HEIGHT
GABLE STUDS
00-00-00
24 IN. OC
END CUT RETURN
PLUMB
REQ. ENGINEERING
JOBSITE
REQ. LAYOUTS
JOBSITE 1 1
QUOTE
LAYOUT
CUTTING
GG1
GG1
DATEBY
SHIP
TO
24 West St
Hatfield, MA 01038
R.K. Miles-HatfieldSOLD
TO (413) 247-8300
SALES REP
ORDER DATE
REQ. QUOTE DATE
DELIVERY DATE
/ /
/ /
09/26/24 ORDER #
QUOTE #
TERMS
SALES AREA
CUSTOMER PO #
CUSTOMER ACCT #
INVOICE #
LMCWRKMI
ORDERED BY
SUPERINTENDENT
JOBSITE PHONE #
DATE OF INVOICE
24090806BR
Tyler Pohl
Massachusetts /
/ /
Ryan Thompson
(413) 247-8300
PAGE 2
SPECIAL INSTRUCTIONS:
DELIVERY INSTRUCTIONS:
JOB NAME:
MODEL: TAG:Roof Trusses
Condo Project-R
BUILDING DEPARTMENT
Roof Trusses
JOB CATEGORY:Single Family Custom
LOT # SUBDIV:
DATE09/30/24
152-154 South Main Street
Northhampton, MA 01062
Ryan Thompson
09/30/24
09/30/24
/ /
DESIGNER Gerson Garcia
QTY TYPE
SPAN LUMBER
TOP BOT
OVERHANG
LEFT RIGHT
CANTILEVER
LEFT RIGHT
PITCH
TOP BOT
ID
TOTALPRICEPRICEUNITPROFILE
ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL
35.0,10.0,0.0,10.0
STRESS INCR.
1.00INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.)ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL
35.0,10.0,0.0,10.0
STRESS INCR.
INFORMATION
PLY LEFT RIGHT
STUBO/ABASE
SPAN
V05 8.00 0.00 12-08-02 2 X 4 2 X 4
VALLEY
2 12-08-02
V06 8.00 0.00 10-02-02 2 X 4 2 X 4
VALLEY
2 10-02-02
V07 8.00 0.00 07-08-02 2 X 4 2 X 4
VALLEY
2 07-08-02
V08 8.00 0.00 05-02-02 2 X 4 2 X 4
VALLEY
2 05-02-02
ROOF SUB-TOTAL:
FT-IN-16
ITEM TYPEQTY SIZE LENGTH PART NUMBER NOTES PRICEUNIT TOTALPRICE
ITEMS
HGUS210-2Hanger 4
HUS210Hanger 18
HUS26-2Hanger 8
LUS24Hanger 12
ITEMS SUB-TOTAL:
ACCEPTED BY BUYER
PURCHASER:
BY:TITLE:
JOB ADDRESS:
PHONE:DATE:
ACCEPTED BY SELLER
BY:
TITLE:
DATE OF ACCEPTANCE:
SUB-TOTAL
GRAND TOTAL
Quote is based on current design values at the time of quote (lumber, EWP, hardware, etc).
Should any of these values change prior to completion of this project,
reserves the right to adjust the sell price accordingly.
QUOTE POLICY: QUOTE VALID FOR 7 DAYS. AFTER 7 DAYS, UFP RESERVES THE RIGHT TO REVIEW / ADJUST ALL PRICING.
Sealed individual truss drawings are included in the pricing.
Sealed layouts, stamped bracing diagrams are NOT included.
Full payment made on net 30 day terms. No pay-if paid terms. UFP reserves the right to hold shipments if we are not paid within the
agreed upon payment terms
PURCHASE ORDER POLICY: Purchase orders are valid for a period of 30 days. Orders moved past a 30 day period are subject
to price review to current market conditions.
$23,480.00
Truss Connector Total ListManuf Product QtySimpson HGUS210-2 4Simpson HUS210 18Simpson HUS26-2 8Simpson LUS24 12
Confirm Skylight Dimensions
Before Order.
Party Wall All the Way to The Top,
Per Plan.
24" Louver Space For
Window At center of truss,
Confirm Before Order.
Do not flip truss backward.Notes1) 5/12 & 8/12 Roof Pitch.2) 12" Overhang Dimension.3) 18" & 19" Heel Height Dimension.
Cantilever Trusses, Confirm
Otherwise Before Order.BBO1BBO2 BBO3BBO4
G01 G01T01GT01T01T01T01T01T01T01T01G02G03T02T03G04G04G03G04T03T03T03T03G04T03T02G02 T01T01T01T01T01T01T01T01T01GT02G
T05
T02G
T05
T06 T06 T06 T06J01J01J01J01
T07 T07 T07 T07
T08T08T09T09T010 T010T03T03V01
V02
V03
V04
V05
V06
V07
V08
V01
V02
V03
V04
V05
V06
V07
V08HUS26-2LUS24HGUS210-2HUS26-2LUS24HGUS210-2LUS24HUS26-2LUS24HUS26-2HUS210HUS210HUS210HUS210HUS210HUS210HUS210HUS210LUS24HUS210LUS24HUS210HUS210HUS210HUS210HUS210HUS210HUS210HUS210HGUS210-2LUS24HUS26-2LUS24HGUS210-2HUS26-2LUS24HUS210LUS24LUS24LUS24HUS26-2HUS26-22' 4"4' 4"9' 4 1/8"9' 4 1/8"9' 4 1/8"9' 4 1/8"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0"1' 7 1/2"2' 0"1' 6 1/2"2' 0" 2' 0"1' 0" 2' 0"1' 6 1/2"2' 0" 2' 0" 2' 0"1' 10 1/2"1' 8"1' 10 1/2"1' 1 1/2"2' 0"1' 10 1/2"1' 8"1' 10 1/2"1' 9" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0"
20' 0" 3' 10"
17' 7 1/2" 3' 6 1/2" 5' 0" 3' 6 1/2" 10' 4" 3' 6 1/2" 5' 0" 3' 6 1/2" 17' 10 1/2"
5' 7" 5' 7" 5' 7" 5' 7" 3' 10" 20' 0"3' 9" 50' 3"54' 0" 1' 0"1' 0" 1' 0" 3' 9" 50' 3"1' 8"1' 0"
1' 1"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 1' 8"1' 0"
1' 1"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 3' 3 1/2"1' 8"20' 0" 30' 0" 20' 0"
70' 0"
9"11 1/2"9"
9"6' 0" 3' 3 1/2" 3' 3 1/2" 3' 3 1/2"TrussTrax.ufpi.comLEFT END OF TRUSS IS NOTED AS (TYPICAL)
Roof Truss @ 24" O.C. U.N.O.
ROOF TRUSS NOTES:This drawing is property of UFP Site Built, LLC.Any unauthorized use of this document withoutwritten permission is prohibited. UFP relinquishesownership of delivered product upon delivery.Owner of product must obtain UFP's authorizationprior to any alteration or modification of product;UFP will not be held responsible for anyunauthorized modifications done or costs incurredwithout prior written authorization from UFP.152-154 South Main StreetNorthampton, MA, 01062Condo Project-RREVISIONSDATE DESCRIPTION DSN- - -- - -- - -- - -- - -- - -- - -- - -
24090806BR
STRUC DATE
JOB #:
DESIGNER GJVG
ARCH DATE
LAYOUT DATE
09/26/2024
09/27/2024
SCALE:N.T.S.THIS IS A TRUSS/COMPONENT PLACEMENT DIAGRAM (TPD) ONLY; NOT AN ENGINEERED DOCUMENT. Trusses are designed as individual buildingcomponents tobe incorporated into the building design at the specification of thebuilding designer. See individual truss design drawings (TDD's) foreach truss designidentified on the TPD. The building designer is responsible for temporaryand permanent bracing of the roof and floor system and for the overall structure. The design of the support structure including but not limited to headers, beams, walls, and columns is also the responsibility of the building designer. For general guidanceregarding installation and bracing, consult "Building Component Safety Information" (BCSI) available from the SBC Association (www.sbcacomponents.com). It is the responsibility of the General Contractor to verify that the provided component layout matches the final intended construction plans, loading conditions, and use. Ifthey do not, it is the responsibility of the General Contractor to notify UFP and provide plans containing the latest specifications and designs. UFP will not be responsible for plan changes by others after final approval of shop drawings, or for errors or modifications made on-site during construction. DO NOT CUT, NOTCH,DRILL, OR OTHERWISE "REPAIR" MANUFACTURED TRUSSES IN ANY WAY WITHOUT PRIOR WRITTEN AUTHORIZATION BY A LICENSED PROFESSIONAL DESIGNATED BY UFP. The Framer is responsible to verify all dimensions, including adjusting member spacing within tolerances to allow for the drop and rise ofplumbing/HVAC, unless noted otherwise. Truss-to-wall connections, if shown, are for uplift only and do not consider lateral loads. All connectors on this project are to be installed per the connector manufacturer's specifications. All connectors shown that are not truss-to-truss are suggestions only and are to be verified by theBuilding Designer or Engineer of Record for suitability to this particular project. UFP accepts no responsibility for the specific application or suitability of any connector that is not truss-to-truss as they apply to this specific structure.
ROOF TRUSS PLACEMENT PLAN (315) 253-2758(413) 213-3722(856) 767-0043(800) 488-2811(800) 333-2092(800) 828-2906(607) 563-1556(603) 824-9690UFP AuburnUFP ChicopeeUFP BerlinUFP GordonUFP HudsonUFP New WindsorUFP SidneyUFP Wilton
Scale = 1:85.1
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF 2100F 1.8E
BOT CHORD 2x10 SP 2400F 2.0E
WEBS 2x4 SPF No.2 *Except*
15-5,11-9,3-18,7-13:2x4 SPF 2100F 1.8E,
10-9:2x8 SP 2400F 2.0E, 21-1:2x6 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
4-2-1 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
bracing, Except:
6-0-0 oc bracing: 20-21,19-20.
WEBS 1 Row at midpt 6-15, 4-18
REACTIONS (size)10=5-08, (min. 1-15), 19=5-08,
(min. 3-10)
Max Horiz 19=267 (LC 7)
Max Uplift 10=-1980 (LC 11), 19=-2494 (LC
10)
Max Grav 10=13201 (LC 17), 19=13677 (LC
1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 5-6=-9096/1443, 6-7=-13054/2030,
7-8=-13229/2010, 8-9=-11137/1672,
2-3=-1092/17, 3-4=-5448/773,
4-5=-9028/1457, 9-10=-11991/1806
BOT CHORD 18-19=-180/883, 17-18=-930/6238,
16-17=-930/6238, 16-22=-930/6238,
15-22=-930/6238, 15-23=-1386/9919,
14-23=-1386/9919, 14-24=-1386/9919,
13-24=-1386/9919, 13-25=-1608/10991,
12-25=-1608/10991, 12-26=-1372/9168,
11-26=-1372/9168, 10-11=-180/1105
WEBS 5-15=-1505/9550, 4-15=-491/2549,
6-15=-5009/919, 3-19=-10787/1748,
7-12=-91/280, 4-17=-287/1988,
6-14=-447/3036, 2-20=-1837/114,
8-11=-3402/511, 2-19=-83/1383,
8-12=-393/2831, 9-11=-1457/9854,
3-18=-1396/8836, 7-13=-473/187,
4-18=-6676/1114, 6-13=-575/3292
NOTES
1)2-ply truss to be connected together with 10d
(0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 4-00 oc,
2x8 - 2 rows staggered at 9-00 oc, 2x6 - 2 rows
staggered at 9-00 oc.
Bottom chords connected as follows: 2x10 - 5 rows
staggered at 4-00 oc.
Web connected as follows: 2x4 - 1 row at 9-00 oc,
Except member 5-15 2x4 - 1 row at 7-00 oc, member
4-17 2x4 - 2 rows staggered at 9-00 oc, member 8-11
2x4 - 2 rows staggered at 2-00 oc.
2)All loads are considered equally applied to all plies,
except if noted as front (F) or back (B) face in the LOAD
CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B),
unless otherwise indicated.
3)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone;
cantilever left and right exposed ; end vertical left and
right exposed; Lumber DOL=1.60 plate grip DOL=1.60
4)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
5)Unbalanced snow loads have been considered for this
design.
6)All plates are MT20 plates unless otherwise indicated.
7)The Fabrication Tolerance at joint 15 = 16%
8)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
9)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members.
10)Bearing at joint(s) 19, 10 considers parallel to grain
value using ANSI/TPI 1 angle to grain formula. Building
designer should verify capacity of bearing surface.
11)Provide metal plate or equivalent at bearing(s) 19 to
support reaction shown.
12)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 2494 lb uplift at
joint 19 and 1980 lb uplift at joint 10.
13)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
14)Use Simpson Strong-Tie LUS24 (4-SD9112 Girder, 2-
SD9212 Truss, Single Ply Girder) or equivalent at 1-1-4
from the left end to connect truss(es) to back face of
bottom chord.
15)Use Simpson Strong-Tie HUS26-2 (4-10d Girder, 4-10d
Truss, Single Ply Girder) or equivalent at 3-0-8 from the
left end to connect truss(es) to back face of bottom
chord.
16)Use Simpson Strong-Tie HGUS210-2 (46-10d Girder,
16-10d Truss) or equivalent at 6-7-0 from the left end to
connect truss(es) to back face of bottom chord.
17)Use Simpson Strong-Tie HUS210 (30-10d Girder,
10-10d Truss) or equivalent spaced at 2-0-0 oc max.
starting at 8-3-4 from the left end to 22-3-4 to connect
truss(es) to back face of bottom chord.
18)Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1)Dead + Snow (balanced): Lumber Increase=1.15, Plate
Increase=1.15
Uniform Loads (lb/ft)
Vert: 5-9=-90, 1-5=-90, 10-28=-20, 21-28=-20
Concentrated Loads (lb)
Vert: 15=-2695 (B), 17=-2695 (B), 11=-2695 (B),
18=-3004 (B), 22=-2695 (B), 23=-2695 (B), 24=-2695
(B), 25=-2695 (B), 26=-2695 (B), 27=137 (B),
28=192 (B)
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
G01 Common Girder 2 224090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:44 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:uqZRaI38BRhiBjdvXxn7mLyZR0r-_BSTDXRzykQcbVN?cELXysxkZKXDZap3ElNJfGyZO7j
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
812
=3x6 =3x8
=5x6
=3x6
=12x12
=8x8
=12x12 =M18AHS 3x12=6x10
=MT20HS 7x14 =8x8
=M18AHS 12x18 =3x8
=6x10
=10x12
=3x6
=10x12
=5x6
=12x12
=8x12
=6x8LUS24
HUS26-2
HGUS210-2
HUS210
HUS210
HUS210
HUS210
HUS210
HUS210
HUS210
HUS210
132127202819181716221523142425 1226 11 10
1 9
2 8
3 7
64
5
T1 T1
W13 W1
B3 B1 B2
W10
W9 W9
W5 W11
W8 W8
W3 W3 W4 W4
W2 W12
W6 W6
W7 W7
3-00-08 3-06-08
2-03-06
2-03-06
2-03-06
22-00-10
2-03-06
4-06-12
2-03-06
24-04-00
3-09-10
19-09-04
3-09-10
8-04-06
3-09-10
12-02-00
3-09-10
15-11-10
2-12
4-06-12
3-10
24-04-00
1-08-15
19-09-04
1-08-15
6-03-11
1-11-12
24-00-06
2-00-11
18-00-05
2-00-11
8-04-06
2-00-10
4-04-00
2-03-06
22-00-10
2-03-06
2-03-06
3-09-10
12-02-00
3-09-10
15-11-101-09-009-10-05Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.50 Vert(LL)-0.14 14-15 >999 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.34 Vert(CT)-0.21 14-15 >999 240 MT20HS 187/143
TCDL 10.0 Rep Stress Incr NO WB 0.99 Horz(CT)0.03 10 n/a n/a M18AHS 142/136
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS Wind(LL)0.07 14-15 >999 240
BCDL 10.0 Weight: 447 lb FT = 20%
Scale = 1:85.6
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x6 SPF No.2 *Except* 21-24:2x6 SPF
2100F 1.8E
WEBS 2x4 SPF No.2 *Except* 24-2,13-12:2x6 SPF
No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (size)13= Mechanical, (min. 1-08),
24=5-08, (min. 2-06)
Max Horiz 24=166 (LC 10)
Max Uplift 13=-476 (LC 11), 24=-711 (LC 10)
Max Grav 13=3024 (LC 1), 24=3771 (LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-3=-5772/1067, 3-4=-6276/1105,
4-5=-5379/904, 5-25=-5263/907,
6-25=-5161/921, 6-7=-4049/715,
7-8=-4049/714, 8-26=-4578/787,
9-26=-4679/773, 9-10=-4796/770,
10-11=-5205/838, 11-12=-4806/753,
2-24=-3570/698, 12-13=-2911/489
BOT CHORD 24-27=-311/690, 23-27=-311/690,
22-23=-1089/5212, 22-28=-1039/5740,
21-28=-1039/5740, 20-21=-1039/5740,
20-29=-756/4858, 19-29=-756/4858,
18-19=-484/4319, 17-18=-484/4319,
16-17=-643/4730, 15-16=-643/4730,
14-15=-657/4339, 13-14=-83/423
WEBS 3-23=-882/134, 6-20=-261/1363,
7-19=-385/2422, 4-22=-96/498,
6-19=-2201/539, 8-17=-68/496,
11-14=-811/191, 10-17=-526/236,
4-20=-1130/363, 8-19=-1369/356,
3-22=-19/661, 11-15=-65/509,
2-23=-795/4622, 12-14=-586/4003
NOTES
1)2-ply truss to be connected together with 10d
(0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows
staggered at 9-00 oc.
Bottom chords connected as follows: 2x6 - 2 rows
staggered at 9-00 oc.
Web connected as follows: 2x4 - 1 row at 9-00 oc.
2)All loads are considered equally applied to all plies,
except if noted as front (F) or back (B) face in the LOAD
CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B),
unless otherwise indicated.
3)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone;
cantilever left and right exposed ; end vertical left and
right exposed; Lumber DOL=1.60 plate grip DOL=1.60
4)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
5)Unbalanced snow loads have been considered for this
design.
6)This truss has been designed for greater of min roof live
load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on
overhangs non-concurrent with other live loads.
7)All plates are 4x4 MT20 unless otherwise indicated.
8)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
9)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members, with BCDL = 10.0psf.
10)Refer to girder(s) for truss to truss connections.
11)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 476 lb uplift at joint
13 and 711 lb uplift at joint 24.
12)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
13)Use Simpson Strong-Tie LUS24 (4-10d Girder, 2-10d
Truss) or equivalent at 4-11-5 from the left end to
connect truss(es) to front face of bottom chord.
14)Use Simpson Strong-Tie HUS26-2 (4-16d Girder, 4-16d
Truss) or equivalent at 14-5-11 from the left end to
connect truss(es) to front face of bottom chord.
15)Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1)Dead + Snow (balanced): Lumber Increase=1.15, Plate
Increase=1.15
Uniform Loads (lb/ft)
Vert: 1-2=-90, 2-7=-90, 7-12=-90, 13-24=-20
Concentrated Loads (lb)
Vert: 27=-282 (F), 28=-953 (F)
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
G02 Common Girder 2 224090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:45 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:J7gb_frUHxo1Ks1df2wB_ayZRYh-SN0rRtSbj2YTDfyBAxsmV3TyOkm_I1DDTP7tBiyZO7i
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
512
=5x8
=5x6
=4x6
=5x6 =5x6
=4x8 =4x6
=4x6
=4x6 =5x6
=5x8
=3x4
LUS24 HUS26-2
24
2723 22 28 21 20 29 19 18 17 16 15 14
13
1 122
113
104
5 9
262586
7
T2
T1
T2
T3
W1 W1 B2 B3 B2 B1
W3
W7
W9
W5 W5
W8 W7
W3
W6 W6
W8
W4 W4
W2 W2
1-00-00
-1-00-00
5-06-00
44-06-00
5-06-00
10-11-15
5-06-00
50-00-00
5-06-00
5-06-00
7-00-00
18-00-00
7-00-00
39-00-01
7-00-00
25-00-00
7-00-00
32-00-00
5-06-00
44-06-00
5-06-00
10-11-15
5-06-00
50-00-00
5-06-00
5-06-00
7-00-00
32-00-00
7-00-00
18-00-00
7-00-00
25-00-00
7-00-00
39-00-011-06-0011-11-00Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.30 Vert(LL)-0.23 20-22 >999 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.82 Vert(CT)-0.37 20-22 >999 240
TCDL 10.0 Rep Stress Incr NO WB 0.98 Horz(CT)0.09 13 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS Wind(LL)0.13 20-22 >999 240
BCDL 10.0 Weight: 619 lb FT = 20%
Scale = 1:85.6
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x6 SPF No.2 *Except* 21-24:2x6 SPF
2100F 1.8E
WEBS 2x4 SPF No.2 *Except* 24-2,13-12:2x6 SPF
No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
bracing, Except:
6-0-0 oc bracing: 14-15,13-14.
REACTIONS (size)13= Mechanical, (min. 1-08),
14=5-08, (min. 3-02), 24=5-08,
(min. 2-02)
Max Horiz 24=166 (LC 10)
Max Uplift 13=-555 (LC 17), 14=-603 (LC 11),
24=-654 (LC 10)
Max Grav 13=116 (LC 10), 14=3949 (LC 1),
24=3305 (LC 17)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-3=-4984/970, 3-4=-5302/987,
4-5=-4335/775, 5-25=-4186/778,
6-25=-4113/792, 6-7=-2926/558,
7-8=-2926/580, 8-26=-2648/492,
9-26=-2755/477, 9-10=-2866/475,
10-11=-1649/297, 11-12=-212/1349,
2-24=-3116/643, 12-13=-83/576
BOT CHORD 24-27=-302/614, 23-27=-302/614,
22-23=-1000/4490, 22-28=-929/4836,
21-28=-929/4836, 20-21=-929/4836,
20-29=-637/3905, 19-29=-637/3905,
18-19=-245/2543, 17-18=-245/2543,
16-17=-134/1432, 15-16=-134/1432,
14-15=-1134/235
WEBS 7-19=-283/1569, 3-23=-729/115,
6-20=-268/1428, 4-22=-108/579,
10-15=-1864/310, 6-19=-2259/548,
8-17=-743/202, 10-17=-215/1463,
4-20=-1226/374, 8-19=-262/438, 3-22=0/466,
11-14=-3539/605, 2-23=-713/3963,
12-14=-1186/219, 11-15=-403/3182
NOTES
1)2-ply truss to be connected together with 10d
(0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows
staggered at 9-00 oc.
Bottom chords connected as follows: 2x6 - 2 rows
staggered at 9-00 oc.
Web connected as follows: 2x4 - 1 row at 9-00 oc.
2)All loads are considered equally applied to all plies,
except if noted as front (F) or back (B) face in the LOAD
CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B),
unless otherwise indicated.
3)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone;
cantilever left and right exposed ; end vertical left and
right exposed; porch right exposed; Lumber DOL=1.60
plate grip DOL=1.60
4)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
5)Unbalanced snow loads have been considered for this
design.
6)This truss has been designed for greater of min roof live
load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on
overhangs non-concurrent with other live loads.
7)All plates are 4x4 MT20 unless otherwise indicated.
8)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
9)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members, with BCDL = 10.0psf.
10)Refer to girder(s) for truss to truss connections.
11)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 555 lb uplift at joint
13, 654 lb uplift at joint 24 and 603 lb uplift at joint 14.
12)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
13)Use Simpson Strong-Tie LUS24 (4-10d Girder, 2-10d
Truss) or equivalent at 4-11-5 from the left end to
connect truss(es) to front face of bottom chord.
14)Use Simpson Strong-Tie HUS26-2 (4-16d Girder, 4-16d
Truss) or equivalent at 14-5-11 from the left end to
connect truss(es) to front face of bottom chord.
15)Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1)Dead + Snow (balanced): Lumber Increase=1.15, Plate
Increase=1.15
Uniform Loads (lb/ft)
Vert: 1-2=-90, 2-7=-90, 7-12=-90, 13-24=-20
Concentrated Loads (lb)
Vert: 27=-282 (F), 28=-953 (F)
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
G03 Common Girder 2 224090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:45 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:7Cx9_T5btu_quKIi00pfTWyZRZf-SN0rRtSbj2YTDfyBAxsmV3TyZknJI1pDTP7tBiyZO7i
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
512
=5x8
=5x6
=4x6
=5x6 =5x6
=4x8 =4x6
=4x6
=4x6
=4x6
=4x6
=5x8
=3x4
LUS24 HUS26-2
24
2723 22 28 21 20 29 19 18 17 16 15 14
13
1 122
3 11
104
5 9
262586
7
T2
T1
T2
T3
W1 W1 B2 B3 B2 B1
W9
W3
W7
W5 W5
W8 W7
W6 W6
W8
W4 W11
W2 W12
W10
1-00-00
-1-00-00
4-09-03
43-09-04
5-06-00
10-11-15
5-06-00
5-06-00
6-02-12
50-00-00
7-00-00
18-00-00
7-00-00
39-00-01
7-00-00
25-00-00
7-00-00
32-00-00
2-12
44-00-00
4-09-03
43-09-04
5-06-00
10-11-15
5-06-00
5-06-00
6-00-00
50-00-00
7-00-00
32-00-00
7-00-00
18-00-00
7-00-00
25-00-00
7-00-00
39-00-011-06-0011-11-00Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.29 Vert(LL)-0.18 20-22 >999 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.74 Vert(CT)-0.29 20-22 >999 240
TCDL 10.0 Rep Stress Incr NO WB 1.00 Horz(CT)0.05 13 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS Wind(LL)0.11 20-22 >999 240
BCDL 10.0 Weight: 620 lb FT = 20%
Scale = 1:86.6
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x6 SPF No.2 *Except* 22-25:2x6 SPF
2100F 1.8E
WEBS 2x4 SPF No.2 *Except* 25-2,14-12:2x6 SPF
No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (size)14=5-08, (min. 2-07), 25=5-08,
(min. 2-06)
Max Horiz 25=-157 (LC 11)
Max Uplift 14=-508 (LC 11), 25=-712 (LC 10)
Max Grav 14=3136 (LC 1), 25=3770 (LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-3=-5770/1067, 3-4=-6273/1105,
4-5=-5376/904, 5-26=-5260/907,
6-26=-5158/921, 6-7=-4046/714,
7-8=-4046/714, 8-27=-4571/786,
9-27=-4675/772, 9-10=-4790/770,
10-11=-5155/841, 11-12=-4933/772,
2-25=-3569/698, 12-14=-3021/527
BOT CHORD 25-28=-303/690, 24-28=-303/690,
23-24=-1080/5209, 23-29=-1030/5737,
22-29=-1030/5737, 21-22=-1030/5737,
21-30=-747/4855, 20-30=-747/4855,
19-20=-466/4315, 18-19=-466/4315,
17-18=-622/4715, 16-17=-622/4715,
15-16=-643/4429, 14-15=-123/598
WEBS 7-20=-385/2421, 3-24=-882/134,
6-21=-261/1363, 4-23=-96/495,
6-20=-2217/539, 8-18=-65/490,
10-18=-512/233, 4-21=-1130/363,
8-20=-1367/357, 3-23=-19/660,
11-15=-692/165, 11-16=-54/428,
2-24=-795/4620, 12-15=-529/3897
NOTES
1)2-ply truss to be connected together with 10d
(0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows
staggered at 9-00 oc.
Bottom chords connected as follows: 2x6 - 2 rows
staggered at 9-00 oc.
Web connected as follows: 2x4 - 1 row at 9-00 oc.
2)All loads are considered equally applied to all plies,
except if noted as front (F) or back (B) face in the LOAD
CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B),
unless otherwise indicated.
3)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone;
cantilever left and right exposed ; end vertical left and
right exposed; Lumber DOL=1.60 plate grip DOL=1.60
4)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
5)Unbalanced snow loads have been considered for this
design.
6)This truss has been designed for greater of min roof live
load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on
overhangs non-concurrent with other live loads.
7)All plates are 4x4 MT20 unless otherwise indicated.
8)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
9)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members, with BCDL = 10.0psf.
10)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 508 lb uplift at joint
14 and 712 lb uplift at joint 25.
11)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
12)Use Simpson Strong-Tie LUS24 (4-10d Girder, 2-10d
Truss) or equivalent at 4-11-5 from the left end to
connect truss(es) to front face of bottom chord.
13)Use Simpson Strong-Tie HUS26-2 (4-16d Girder, 4-16d
Truss) or equivalent at 14-5-11 from the left end to
connect truss(es) to front face of bottom chord.
14)Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1)Dead + Snow (balanced): Lumber Increase=1.15, Plate
Increase=1.15
Uniform Loads (lb/ft)
Vert: 1-2=-90, 2-7=-90, 7-12=-90, 12-13=-90,
14-25=-20
Concentrated Loads (lb)
Vert: 28=-282 (F), 29=-953 (F)
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
G04 Common Girder 4 224090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:46 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:C4Dx2kgJB7uP1?DONkyJ4cyZRJQ-waaDeDTDUMgKrpXOjfN?1H07676D1ULMh3sQk8yZO7h
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
512
=5x8
=5x6
=4x6
=5x6 =5x6
=4x8 =4x6
=4x6
=4x6 =5x6
=6x8
=3x4
LUS24 HUS26-2
25
2824 23 29 22 21 30 20 19 18 17 16 15
14
131122
3 11
104
95
272686
7
T2
T1
T2
T1
W1 W1 B2 B2 B1 B3
W9
W3
W7
W5 W5
W8 W7
W6 W6
W8
W4 W11 W10
W2 W12
1-00-00
51-00-00
1-00-00
-1-00-00
4-09-03
43-09-04
5-06-00
10-11-15
5-06-00
5-06-00
6-02-12
50-00-00
7-00-00
18-00-00
7-00-00
39-00-01
7-00-00
25-00-00
7-00-00
32-00-00
4-09-03
43-09-04
5-06-00
10-11-15
5-06-00
5-06-00
6-02-12
50-00-00
7-00-00
32-00-00
7-00-00
18-00-00
7-00-00
25-00-00
7-00-00
39-00-011-06-0011-11-00Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.31 Vert(LL)-0.23 21-23 >999 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.82 Vert(CT)-0.37 21-23 >999 240
TCDL 10.0 Rep Stress Incr NO WB 0.98 Horz(CT)0.09 14 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS Wind(LL)0.13 21-23 >999 240
BCDL 10.0 Weight: 624 lb FT = 20%
Scale = 1:31.9
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
4-10-9 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (size)4= Mechanical, (min. 1-08), 5=5-08,
(min. 1-08)
Max Horiz 5=145 (LC 9)
Max Uplift 4=-66 (LC 9), 5=-66 (LC 12)
Max Grav 4=267 (LC 19), 5=379 (LC 19)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-5=-333/177
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for
members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)This truss has been designed for greater of min roof live
load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on
overhangs non-concurrent with other live loads.
5)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
6)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members.
7)All bearings are assumed to be User Defined crushing
capacity of 425 psi.
8)Refer to girder(s) for truss to truss connections.
9)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 66 lb uplift at joint
5 and 66 lb uplift at joint 4.
10)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
J01 Jack-Closed 4 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:46 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:Asx8PYuZSCEsD0R7uUCbG2yZoCX-waaDeDTDUMgKrpXOjfN?1H04_7Fg1jOMh3sQk8yZO7h
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
512
=2x4
=3x4
=4x4 =2x4
5 4
1
2
6
3
W1
T1
W3
B1
W2
1-00-00
-1-00-00
4-10-09
4-10-09
4-10-093-06-061-06-003-06-06Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.51 Vert(LL)-0.03 4-5 >999 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.22 Vert(CT)-0.05 4-5 >999 240
TCDL 10.0 Rep Stress Incr YES WB 0.02 Horz(CT)0.00 4 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MP
BCDL 10.0 Weight: 22 lb FT = 20%
Scale = 1:85.6
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF No.2 *Except* 24-2,13-12:2x8 SP
2400F 2.0E
BRACING
TOP CHORD Structural wood sheathing directly applied or
3-2-9 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
bracing, Except:
8-11-9 oc bracing: 22-23
9-2-1 oc bracing: 20-22.
WEBS 1 Row at midpt 6-19, 10-17, 4-20, 8-19
REACTIONS (size)13= Mechanical, (min. 1-08),
24=5-08, (min. 4-07)
Max Horiz 24=166 (LC 12)
Max Uplift 13=-405 (LC 13), 24=-439 (LC 12)
Max Grav 13=2715 (LC 1), 24=2836 (LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-25=-4212/650, 3-25=-4084/668,
3-4=-4514/755, 4-5=-4086/735,
5-26=-3970/748, 6-26=-3868/751,
6-27=-3334/686, 7-27=-3205/711,
7-28=-3205/711, 8-28=-3334/686,
8-29=-3870/756, 9-29=-3973/741,
9-10=-4088/739, 10-11=-4543/771,
11-12=-4228/695, 2-24=-2730/535,
12-13=-2607/465
BOT CHORD 23-24=-252/494, 22-23=-682/3777,
21-22=-652/4112, 20-21=-652/4112,
20-30=-483/3664, 19-30=-483/3664,
18-19=-428/3667, 17-18=-428/3667,
16-17=-527/4118, 15-16=-527/4118,
14-15=-544/3808, 13-14=-77/399
WEBS 3-23=-698/160, 6-20=-61/499,
7-19=-303/1878, 6-19=-1361/348,
8-17=-61/504, 11-14=-729/174,
10-17=-578/216, 4-20=-574/216,
8-19=-1383/349, 3-22=-40/426,
11-15=-38/405, 2-23=-440/3362,
12-14=-495/3492
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) -1-0-0 to 4-0-0, Interior (1) 4-0-0 to
20-0-0, Exterior (2) 20-0-0 to 30-0-0, Interior (1) 30-0-0
to 44-6-0, Exterior (2) 44-6-0 to 49-8-6 zone; cantilever
left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)This truss has been designed for greater of min roof live
load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on
overhangs non-concurrent with other live loads.
5)All plates are 4x4 MT20 unless otherwise indicated.
6)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
7)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members, with BCDL = 10.0psf.
8)Refer to girder(s) for truss to truss connections.
9)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 439 lb uplift at joint
24 and 405 lb uplift at joint 13.
10)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
T01 Common 16 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:46 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:9mvKO51fuhoD61b_sw?MXByZSTr-waaDeDTDUMgKrpXOjfN?1H03577J1WKMh3sQk8yZO7h
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
512
=3x8
=6x10
=8x8
=4x6
=5x6 =5x6
=5x8 =5x6
=4x6
=5x6 =8x8
=6x10
=3x8
24
23 22 21 20 30 19 18 17 16 15 14
13
1 122
25 113
104
95
292686
2827
7
T2
T1
T2
T3
W1 W1 B2 B3 B2 B1
W3
W7
W9
W5 W5
W8 W7
W3
W6 W6
W8
W4 W4
W2 W2
1-00-00
-1-00-00
5-06-00
44-06-00
5-06-00
10-11-15
5-06-00
50-00-00
5-06-00
5-06-00
7-00-00
18-00-00
7-00-00
39-00-01
7-00-00
25-00-00
7-00-00
32-00-00
5-06-00
44-06-00
5-06-00
10-11-15
5-06-00
50-00-00
5-06-00
5-06-00
7-00-00
32-00-00
7-00-00
18-00-00
7-00-00
25-00-00
7-00-00
39-00-011-06-0011-11-00Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.56 Vert(LL)-0.29 17-19 >999 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.75 Vert(CT)-0.46 17-19 >999 240
TCDL 10.0 Rep Stress Incr YES WB 0.86 Horz(CT)0.16 13 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS Wind(LL)0.15 19-20 >999 240
BCDL 10.0 Weight: 312 lb FT = 20%
Scale = 1:85.6
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x8 SP 2400F 2.0E
OTHERS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
WEBS 1 Row at midpt 16-46, 15-47, 14-48,
13-49, 17-44, 18-43,
19-42
REACTIONS All bearings 50-00-00.
(lb) -Max Horiz 60=166 (LC 12)
Max Uplift All uplift 100 (lb) or less at joint(s)
31, 33, 34, 35, 36, 37, 39, 40, 41,
42, 43, 44, 47, 48, 49, 50, 52, 53,
54, 55, 56, 57, 58 except 32=-294
(LC 13), 59=-369 (LC 12), 60=-105
(LC 17)
Max Grav All reactions 250 (lb) or less at joint
(s) 32, 33, 34, 35, 36, 37, 39, 40,
46, 52, 53, 54, 55, 56, 57, 58, 59
except 31=301 (LC 13), 41=272
(LC 20), 42=323 (LC 20), 43=329
(LC 20), 44=328 (LC 20), 47=325
(LC 19), 48=325 (LC 19), 49=320
(LC 19), 50=270 (LC 19), 60=412
(LC 24)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-60=-333/60, 2-3=-260/85, 11-12=-100/265,
12-13=-114/305, 13-62=-129/344,
14-62=-121/351, 14-15=-145/419,
15-16=-154/467, 16-17=-154/467,
17-18=-145/419, 18-63=-121/351,
19-63=-129/344, 19-20=-114/305,
20-21=-100/265
WEBS 15-47=-284/104, 14-48=-285/157,
13-49=-280/100, 17-44=-287/104,
18-43=-288/157, 19-42=-283/100
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Corner (3) -1-0-0 to 4-0-0, Exterior (2) 4-0-0 to
20-0-0, Corner (3) 20-0-0 to 30-0-0, Exterior (2) 30-0-0
to 44-8-6, Corner (3) 44-8-6 to 49-8-6 zone; cantilever
left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Truss designed for wind loads in the plane of the truss
only. For studs exposed to wind (normal to the face),
see Standard Industry Gable End Details as applicable,
or consult qualified building designer as per ANSI/TPI 1.
3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
4)Unbalanced snow loads have been considered for this
design.
5)This truss has been designed for greater of min roof live
load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on
overhangs non-concurrent with other live loads.
6)All plates are 2x4 MT20 unless otherwise indicated.
7)Gable requires continuous bottom chord bearing.
8)Truss to be fully sheathed from one face or securely
braced against lateral movement (i.e. diagonal web).
9)Gable studs spaced at 2-0-0 oc.
10)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
11)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members.
12)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 100 lb uplift at joint
(s) 31, 47, 48, 49, 50, 52, 53, 54, 55, 56, 57, 58, 44, 43,
42, 41, 40, 39, 37, 36, 35, 34, 33 except (jt=lb) 60=105,
59=369, 32=294.
13)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
T01G Common Supported Gable 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:47 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:X?6mwmhmY4bpcnZ08bmfwnyZSDV-Om8brZUrFfoBSz5aHMuEaUZLiXc7m6yVwjczGayZO7g
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
512
=3x4 =3x4
=4x6
=4x6 =5x6
=4x6
=4x6
=4x6 =3x4
=3x4
60
59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32
31
1 302293
2846127564
266
257
248
23922102111
2012
191363621814
1715
16
W1
T2
T1
T2
T3
W1 B1 B3 B3 B2
ST13 ST12 ST11 ST10 ST9 ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1
ST12 ST11 ST10 ST9 ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1
1-00-00
-1-00-00
25-00-00
50-00-00
25-00-00
25-00-00
50-00-001-06-0011-11-00Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.12 Vert(LL)n/a -n/a 999 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.07 Vert(CT)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.26 Horz(CT)0.01 31 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MR
BCDL 10.0 Weight: 360 lb FT = 20%
Scale = 1:85.8
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF No.2 *Except* 24-2,13-12:2x8 SP
2400F 2.0E
BRACING
TOP CHORD Structural wood sheathing directly applied or
3-7-4 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
WEBS 1 Row at midpt 6-19, 8-17, 4-20, 8-19
REACTIONS (size)13= Mechanical, (min. 1-08),
14=5-08, (min. 5-06), 24=5-08,
(min. 3-13)
Max Horiz 24=166 (LC 12)
Max Uplift 13=-392 (LC 19), 14=-472 (LC 13),
24=-398 (LC 12)
Max Grav 13=74 (LC 12), 14=3410 (LC 1),
24=2437 (LC 19)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-25=-3548/544, 3-25=-3420/562,
3-4=-3707/624, 4-5=-3200/591,
5-26=-3052/605, 6-26=-2977/608,
6-27=-2376/537, 7-27=-2245/561,
7-28=-2245/561, 8-28=-2377/537,
8-29=-2223/499, 9-29=-2330/484,
9-10=-2441/483, 10-11=-1513/296,
11-30=-117/1052, 12-30=-137/935,
2-24=-2340/472, 12-13=-42/420
BOT CHORD 23-24=-245/434, 22-23=-618/3170,
21-22=-573/3345, 20-21=-573/3345,
20-31=-398/2856, 19-31=-398/2856,
18-19=-194/2151, 17-18=-194/2151,
16-17=-112/1310, 15-16=-112/1310,
14-15=-863/171
WEBS 7-19=-190/1150, 3-23=-566/146,
6-20=-67/550, 10-15=-1548/278,
6-19=-1410/354, 8-17=-555/159,
10-17=-144/1123, 4-20=-658/225,
8-19=-446/255, 3-22=-16/257,
11-15=-317/2684, 2-23=-382/2807,
12-14=-937/242, 11-14=-3053/504
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) -1-0-0 to 4-0-0, Interior (1) 4-0-0 to
20-0-0, Exterior (2) 20-0-0 to 30-0-0, Interior (1) 30-0-0
to 44-8-6, Exterior (2) 44-8-6 to 49-8-6 zone; cantilever
left and right exposed ; end vertical left and right
exposed; porch right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)This truss has been designed for greater of min roof live
load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on
overhangs non-concurrent with other live loads.
5)All plates are 4x4 MT20 unless otherwise indicated.
6)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
7)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members, with BCDL = 10.0psf.
8)Refer to girder(s) for truss to truss connections.
9)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 392 lb uplift at joint
13, 398 lb uplift at joint 24 and 472 lb uplift at joint 14.
10)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
T02 Common 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:47 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:vDHJS4FlXU2pMcZnyydJ7fyZRec-Om8brZUrFfoBSz5aHMuEaUZEWXUbm_NVwjczGayZO7g
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
512
=4x8
=6x8
=6x6
=4x4
=4x4
=4x4
=4x6
=4x6
=4x4
=4x4 =5x6
=4x8 =4x6
=4x4
=4x4
=4x6
=4x6
=4x4
=6x6
=6x8
=4x6
=5x8
=4x10
24
23 22 21 20 31 19 18 17 16 15 14
13
1 122
25 30311
104
5 9
292686
2827
7
T2
T1
T2
T3
W1 W1 B2 B3 B2 B1
W9
W3
W7
W5 W5
W8 W7
W6 W6
W8
W4 W10
W2 W12
W11
1-00-00
-1-00-00
4-09-03
43-09-04
5-06-00
10-11-15
5-06-00
5-06-00
6-02-12
50-00-00
7-00-00
18-00-00
7-00-00
39-00-01
7-00-00
25-00-00
7-00-00
32-00-00
2-12
44-00-00
4-09-03
43-09-04
5-06-00
10-11-15
5-06-00
5-06-00
6-00-00
50-00-00
7-00-00
32-00-00
7-00-00
18-00-00
7-00-00
25-00-00
7-00-00
39-00-011-06-0011-11-00Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.52 Vert(LL)-0.18 20-22 >999 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.62 Vert(CT)-0.30 20-22 >999 240
TCDL 10.0 Rep Stress Incr YES WB 0.81 Horz(CT)0.09 13 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS Wind(LL)0.10 20-22 >999 240
BCDL 10.0 Weight: 312 lb FT = 20%
Scale = 1:56.7
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
REACTIONS All bearings 20-00-00.
(lb) -Max Horiz 28=256 (LC 11)
Max Uplift All uplift 100 (lb) or less at joint(s)
18, 19, 25, 26 except 16=-260 (LC
9), 17=-296 (LC 8), 21=-123 (LC
13), 24=-122 (LC 12), 27=-322 (LC
9), 28=-291 (LC 8)
Max Grav All reactions 250 (lb) or less at joint
(s) 18, 19, 25, 26 except 16=353
(LC 22), 17=339 (LC 11), 21=271
(LC 20), 22=301 (LC 20), 23=301
(LC 19), 24=271 (LC 19), 27=367
(LC 10), 28=378 (LC 23)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-28=-289/172, 6-7=-200/284,
9-10=-200/284, 14-16=-289/153
WEBS 7-23=-257/13, 9-22=-257/13
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Corner (3) -1-0-0 to 2-0-0, Exterior (2) 2-0-0 to
6-10-4, Corner (3) 6-10-4 to 13-1-12, Exterior (2)
13-1-12 to 18-0-0, Corner (3) 18-0-0 to 21-0-0 zone;
cantilever left and right exposed ; end vertical left and
right exposed;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Truss designed for wind loads in the plane of the truss
only. For studs exposed to wind (normal to the face),
see Standard Industry Gable End Details as applicable,
or consult qualified building designer as per ANSI/TPI 1.
3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
4)Unbalanced snow loads have been considered for this
design.
5)This truss has been designed for greater of min roof live
load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on
overhangs non-concurrent with other live loads.
6)All plates are 2x4 MT20 unless otherwise indicated.
7)Gable requires continuous bottom chord bearing.
8)Truss to be fully sheathed from one face or securely
braced against lateral movement (i.e. diagonal web).
9)Gable studs spaced at 2-0-0 oc.
10)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
11)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members, with BCDL = 10.0psf.
12)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 100 lb uplift at joint
(s) 25, 26, 19, 18 except (jt=lb) 28=290, 16=259,
24=122, 27=321, 21=123, 17=296.
13)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
T02G Common Supported Gable 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:48 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:6RW2zxnv8JfTfxKJ?lkEkeyZS0T-Om8brZUrFfoBSz5aHMuEaUZJPXb8m7BVwjczGayZO7g
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
812
=3x4 =3x4 =3x6
=3x4 =3x4
=3x4
28
27 26 25 24 23 22 21 20 19 18 17
16
1 15
2 14
3 13
4 12
115
29 30106
97
8
W1
T1 T1
W1
B1 B2
ST5 ST5
ST4
ST3
ST2
ST1
ST4
ST3
ST2
ST1
2-00-00
1-00-00
-1-00-00
1-00-00
21-00-00
10-00-00
10-00-00
10-00-00
20-00-00
20-00-001-09-008-05-00Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.21 Vert(LL)n/a -n/a 999 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.14 Vert(CT)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.24 Horz(CT)0.00 16 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MR
BCDL 10.0 Weight: 107 lb FT = 20%
Scale = 1:86.6
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF No.2 *Except* 25-2,14-12:2x8 SP
2400F 2.0E
BRACING
TOP CHORD Structural wood sheathing directly applied or
3-2-9 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 9-0-6 oc
bracing.
WEBS 1 Row at midpt 6-20, 10-18, 4-21, 8-20
REACTIONS (size)14=5-08, (min. 4-07), 25=5-08,
(min. 4-07)
Max Horiz 25=-156 (LC 13)
Max Uplift 14=-439 (LC 13), 25=-439 (LC 12)
Max Grav 14=2834 (LC 1), 25=2834 (LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-26=-4210/646, 3-26=-4082/664,
3-4=-4510/750, 4-5=-4083/729,
5-27=-3966/730, 6-27=-3864/745,
6-28=-3330/680, 7-28=-3201/704,
7-29=-3201/704, 8-29=-3330/680,
8-30=-3864/745, 9-30=-3966/730,
9-10=-4083/729, 10-11=-4510/750,
11-31=-4082/664, 12-31=-4210/646,
2-25=-2728/532, 12-14=-2728/532
BOT CHORD 24-25=-243/495, 23-24=-672/3775,
22-23=-642/4109, 21-22=-642/4109,
21-32=-474/3661, 20-32=-474/3661,
19-20=-387/3661, 18-19=-387/3661,
17-18=-487/4109, 16-17=-487/4109,
15-16=-516/3775, 14-15=-94/494
WEBS 3-24=-698/160, 6-21=-61/499,
7-20=-298/1875, 6-20=-1378/348,
8-18=-62/503, 11-15=-698/159,
10-18=-574/216, 4-21=-574/216,
8-20=-1378/348, 3-23=-40/425,
11-16=-40/425, 2-24=-440/3360,
12-15=-432/3360
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) -1-0-0 to 4-0-0, Interior (1) 4-0-0 to
20-0-0, Exterior (2) 20-0-0 to 30-0-0, Interior (1) 30-0-0
to 46-0-0, Exterior (2) 46-0-0 to 51-0-0 zone; cantilever
left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)This truss has been designed for greater of min roof live
load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on
overhangs non-concurrent with other live loads.
5)All plates are 4x4 MT20 unless otherwise indicated.
6)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
7)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members, with BCDL = 10.0psf.
8)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 439 lb uplift at joint
14 and 439 lb uplift at joint 25.
9)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
T03 Common 8 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:48 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:DDMxw1BcHkatRG7gp?twAnyZRUN-syi_3vUU0zw247gmr4QT7i5PYxooVRKf9NLXo1yZO7f
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
512
=3x8
=5x10
=6x8
=4x6
=5x6 =5x6
=5x8 =5x6
=4x6
=5x6 =6x8
=5x10
=3x8
25
24 23 22 21 32 20 19 18 17 16 15
14
131122
3126113
104
95
302786
2928
7
T2
T1
T2
T1
W1 W1 B2 B3 B2 B1
W3
W7
W9
W5 W5
W8 W7
W3
W6 W6
W8
W4 W4
W2 W2
1-00-00
51-00-00
1-00-00
-1-00-00
5-06-00
44-06-00
5-06-00
10-11-15
5-06-00
50-00-00
5-06-00
5-06-00
7-00-00
18-00-00
7-00-00
39-00-01
7-00-00
25-00-00
7-00-00
32-00-00
5-06-00
44-06-00
5-06-00
10-11-15
5-06-00
50-00-00
5-06-00
5-06-00
7-00-00
32-00-00
7-00-00
18-00-00
7-00-00
25-00-00
7-00-00
39-00-011-06-0011-11-00Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.57 Vert(LL)-0.29 20-21 >999 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.75 Vert(CT)-0.46 20-21 >999 240
TCDL 10.0 Rep Stress Incr YES WB 0.82 Horz(CT)0.16 14 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS Wind(LL)0.15 20-21 >999 240
BCDL 10.0 Weight: 313 lb FT = 20%
Scale = 1:70.1
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF 2100F 1.8E *Except* 23-22:2x4
SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
WEBS 1 Row at midpt 12-25
JOINTS 1 Brace at Jt(s): 16,
14, 10, 8
REACTIONS (size)22=5-08, (min. 1-12), 25=5-08,
(min. 2-04)
Max Horiz 25=295 (LC 11)
Max Uplift 22=-174 (LC 13), 25=-254 (LC 12)
Max Grav 22=1097 (LC 1), 25=1754 (LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 17-18=-608/181, 18-19=-831/168,
20-28=-286/139, 20-22=-401/200,
5-6=-58/993, 6-8=-237/764, 8-10=-181/823,
10-12=-118/924, 12-14=-899/271,
14-16=-766/228, 16-17=-713/242
BOT CHORD 25-26=-770/236, 24-25=-93/629,
23-24=-77/742, 22-23=-77/742
WEBS 3-26=-349/36, 6-25=-443/222,
17-24=-83/419, 12-25=-1859/304,
19-22=-869/87, 5-26=-129/772, 3-5=-177/259
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) -1-0-0 to 2-2-0, Interior (1) 2-2-0 to
9-2-0, Exterior (2) 9-2-0 to 15-2-0, Interior (1) 15-2-0 to
22-4-0, Exterior (2) 22-4-0 to 25-4-0 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-
C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss
only. For studs exposed to wind (normal to the face),
see Standard Industry Gable End Details as applicable,
or consult qualified building designer as per ANSI/TPI 1.
3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
4)Unbalanced snow loads have been considered for this
design.
5)This truss has been designed for greater of min roof live
load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on
overhangs non-concurrent with other live loads.
6)All plates are 2x4 MT20 unless otherwise indicated.
7)Truss to be fully sheathed from one face or securely
braced against lateral movement (i.e. diagonal web).
8)Gable studs spaced at 2-0-0 oc.
9)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
10)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members.
11)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 174 lb uplift at joint
22 and 254 lb uplift at joint 25.
12)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
13)Graphical purlin representation does not depict the size
or the orientation of the purlin along the top and/or
bottom chord.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
T05 Common Structural Gable 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:48 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:McHycpiFVKtZXeFm4PKFJxyZR7m-syi_3vUU0zw247gmr4QT7i5PaxsDVS5f9NLXo1yZO7f
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
812
=3x4 =3x6
=3x4 =3x6
=5x12
=4x10
=3x4
=5x6 =4x4
=4x6
=3x8
=3x4
=3x4
=4x4
=3x8 =4x4
27
26 25 24 23
22
1 21
5 2026
8 283
104
1912147
16911 18
1713
15
T3
T1
T3
T1
W1 W1
T2
B1 B2
ST3
W6
W5 W5 W4 W7
W3
W2
ST5
ST4
ST4
ST4
ST2
ST1
1-00-00
25-04-00
1-00-00
-1-00-00
2-01-12
4-03-12
8-00
9-05-14
2-02-00
2-02-00
3-04-02
15-06-02
3-08-00
19-02-02
2-08-02
12-02-00
5-01-14
24-04-00
4-06-02
8-09-14
2-03
4-06-03
2-02-00
4-04-00
2-02-00
2-02-00
9-09-13
14-04-00
10-00-00
24-04-009-10-051-09-007-055-10-121-08-131-08-136-06-018-02-141-07-079-10-05Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.56 Vert(LL)-0.20 22-24 >999 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.47 Vert(CT)-0.40 22-24 >592 240
TCDL 10.0 Rep Stress Incr YES WB 0.71 Horz(CT)0.02 22 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS Wind(LL)0.01 24-25 >999 240
BCDL 10.0 Weight: 146 lb FT = 20%
Scale = 1:33.9
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF No.2
BRACING
TOP CHORD 2-0-0 oc purlins: 1-2, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (size)3= Mechanical, (min. 1-08), 4=
Mechanical, (min. 1-08)
Max Horiz 4=-124 (LC 6)
Max Uplift 3=-140 (LC 7), 4=-132 (LC 6)
Max Grav 3=302 (LC 1), 4=275 (LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone;
cantilever left and right exposed ; end vertical left and
right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)Provide adequate drainage to prevent water ponding.
5)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
6)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members.
7)Refer to girder(s) for truss to truss connections.
8)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 132 lb uplift at joint
4 and 140 lb uplift at joint 3.
9)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
10)Graphical purlin representation does not depict the size
or the orientation of the purlin along the top and/or
bottom chord.
11)Use Simpson Strong-Tie LUS24 (4-10dx1 1/2 Girder,
2-10d Truss, Single Ply Girder) or equivalent at 1-9-12
from the left end to connect truss(es) to back face of
bottom chord.
12)Fill all nail holes where hanger is in contact with lumber.
13)In the LOAD CASE(S) section, loads applied to the face
of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1)Dead + Snow (balanced): Lumber Increase=1.15, Plate
Increase=1.15
Uniform Loads (lb/ft)
Vert: 1-2=-90, 3-4=-20
Concentrated Loads (lb)
Vert: 5=-247 (B)
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
T06 Flat Girder 4 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:49 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:g3P3NAnbDJz4W?QjvJ?5G8yZRlh-K9GMGFV6nH2viHFzPnxifvefTLFgE41oN154KTyZO7e
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.=2x4
=3x4
=4x4 =2x4
LUS24
4
5
3
1 2
W1
T1
W1
B1
W2
3-03-08
3-03-083-06-06Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.23 Vert(LL)-0.01 3-4 >999 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.26 Vert(CT)-0.01 3-4 >999 240
TCDL 10.0 Rep Stress Incr NO WB 0.03 Horz(CT)0.00 3 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MP Wind(LL)0.00 3-4 >999 240
BCDL 10.0 Weight: 20 lb FT = 20%
Scale = 1:29.1
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF No.2
BRACING
TOP CHORD 2-0-0 oc purlins: 1-2, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS (size)3= Mechanical, (min. 1-08), 4=
Mechanical, (min. 1-08)
Max Horiz 4=-120 (LC 6)
Max Uplift 3=-182 (LC 7), 4=-165 (LC 6)
Max Grav 3=973 (LC 1), 4=811 (LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 1-4=-781/180, 2-3=-943/135
NOTES
1)2-ply truss to be connected together with 10d
(0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 9-00 oc,
2x6 - 2 rows staggered at 9-00 oc.
Bottom chords connected as follows: 2x6 - 2 rows
staggered at 9-00 oc.
Web connected as follows: 2x4 - 1 row at 9-00 oc.
2)All loads are considered equally applied to all plies,
except if noted as front (F) or back (B) face in the LOAD
CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B),
unless otherwise indicated.
3)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone;
cantilever left and right exposed ; end vertical left and
right exposed; Lumber DOL=1.60 plate grip DOL=1.60
4)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
5)Unbalanced snow loads have been considered for this
design.
6)Provide adequate drainage to prevent water ponding.
7)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
8)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members.
9)Refer to girder(s) for truss to truss connections.
10)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 165 lb uplift at joint
4 and 182 lb uplift at joint 3.
11)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
12)Graphical purlin representation does not depict the size
or the orientation of the purlin along the top and/or
bottom chord.
13)Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 1524
lb down and 158 lb up at 1-9-12 on top chord. The
design/selection of such connection device(s) is the
responsibility of others.
LOAD CASE(S) Standard
1)Dead + Snow (balanced): Lumber Increase=1.15, Plate
Increase=1.15
Uniform Loads (lb/ft)
Vert: 1-2=-90, 3-4=-20
Concentrated Loads (lb)
Vert: 5=-1454
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
T07 Flat Girder 4 224090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:49 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:9t7?_O0CyyyTMqoWRRLExsyZRk4-K9GMGFV6nH2viHFzPnxifveXhLJRE4LoN154KTyZO7e
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.=2x4
=4x4
=4x6 =2x4
4 3
1 5 2
W1
T1
W1
B1
W2
3-03-08
3-03-083-06-06Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.73 Vert(LL)0.00 3-4 >999 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.02 Vert(CT)0.00 3-4 >999 240
TCDL 10.0 Rep Stress Incr NO WB 0.01 Horz(CT)0.00 3 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MP
BCDL 10.0 Weight: 44 lb FT = 20%
Scale = 1:81
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2 *Except* 1-3:2x4 SPF 2100F
1.8E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
2-2-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
bracing, Except:
6-0-0 oc bracing: 10-11.
WEBS 1 Row at midpt 2-16, 4-13, 4-15
REACTIONS (size)9=6-05-08, (min. 3-11),
10=6-05-08, (min. 3-11), 19=3-00,
(min. 1-08)
Max Horiz 19=-245 (LC 13)
Max Uplift 9=-56 (LC 13), 10=-337 (LC 13),
19=-190 (LC 13)
Max Grav 9=114 (LC 19), 10=2241 (LC 1),
19=1544 (LC 18)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 1-20=-660/227, 2-20=-552/237,
2-21=-1114/320, 21-22=-1102/334,
3-22=-985/347, 3-23=-985/349,
23-24=-1000/336, 4-24=-1119/325,
4-5=-1355/339, 5-6=-1466/322,
6-7=-1086/270, 7-25=0/443, 8-25=-10/334
BOT CHORD 16-26=-25/628, 15-26=-25/628,
14-15=-68/1251, 13-14=-68/1251,
13-27=-110/925, 12-27=-110/925,
11-12=-110/925, 10-11=-309/66
WEBS 2-16=-1205/214, 3-15=-80/285,
6-11=-897/162, 2-15=-56/571, 6-13=-2/423,
1-16=-213/1416, 4-15=-618/259,
7-11=-164/1586, 8-10=-448/86,
7-10=-2030/379, 1-19=-1548/293
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) 14-9-7 to 18-4-4, Interior (1) 18-4-4
to 21-5-4, Exterior (2) 21-5-4 to 28-6-12, Interior (1)
28-6-12 to 46-3-8, Exterior (2) 46-3-8 to 49-10-4 zone;
cantilever left and right exposed ; end vertical left and
right exposed;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
5)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members, with BCDL = 10.0psf.
6)Bearing at joint(s) 19 considers parallel to grain value
using ANSI/TPI 1 angle to grain formula. Building
designer should verify capacity of bearing surface.
7)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 56 lb uplift at joint
9, 337 lb uplift at joint 10 and 190 lb uplift at joint 19.
8)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
T08 Common 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:49 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:464DtxUIClO318X13drSiIyZS4j-K9GMGFV6nH2viHFzPnxifveUlLBBEytoN154KTyZO7e
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
512
=3x6
=4x4
=4x10
=5x6
=3x4 =5x6
=3x8 =3x6
=3x4
=3x4
=3x8
=3x6
=3x4
=4x6
=5x6
=4x4
=5x6
=3x4
17
16 26 15 14 13 27 12 11 10
9
8
25
19
18 7
6
51
20 2 421
242322
3
T1 T2
T3
W1
W11
B3 B2 B1
W3
W5
W7
W4 W3
W6
W2
W4
W8
W10
W9
BL1
3-07-13
3-07-13
4-08-03
29-04-01
6-03-12
35-07-13
7-00-00
24-07-14
7-00-00
17-07-13
7-00-00
10-07-13
1-00-01
24-07-14
3-00-00
13-07-13
3-04-05
3-07-13
3-08
3-08
4-00-00
17-07-13
4-08-03
29-04-01
6-00-00
23-07-13
6-03-12
35-07-13
7-00-00
10-07-1311-11-003-11-061-06-008-04-103-06-06Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.92 Vert(LL)-0.10 13-15 >999 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.55 Vert(CT)-0.16 13-15 >999 240
TCDL 10.0 Rep Stress Incr YES WB 0.55 Horz(CT)0.29 10 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS Wind(LL)0.03 13-15 >999 240
BCDL 10.0 Weight: 197 lb FT = 20%
Scale = 1:80.8
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2 *Except* 1-3:2x4 SPF 2100F
1.8E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF No.2 *Except* 10-8:2x6 SPF No.2
OTHERS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
2-2-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 9-3-9 oc
bracing.
WEBS 1 Row at midpt 2-17, 6-14, 4-16
REACTIONS (size)10=5-08, (min. 3-04), 20=3-00,
(min. 1-08)
Max Horiz 20=-262 (LC 13)
Max Uplift 10=-366 (LC 13), 20=-246 (LC 13)
Max Grav 10=2054 (LC 1), 20=1905 (LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 1-21=-814/259, 2-21=-719/269,
2-22=-1491/373, 22-23=-1479/386,
3-23=-1363/400, 3-24=-1363/402,
24-25=-1377/388, 4-25=-1496/378,
4-5=-2086/463, 5-6=-2304/447,
6-7=-2848/537, 7-26=-2799/506,
8-26=-2914/485, 8-10=-1986/393
BOT CHORD 17-27=-28/751, 16-27=-28/751,
15-16=-171/2024, 14-15=-171/2024,
14-28=-343/2560, 13-28=-343/2560,
12-13=-343/2560, 11-12=-402/2584,
10-11=-81/256
WEBS 3-16=-126/521, 2-17=-1450/238,
2-16=-99/870, 4-14=-72/635, 6-14=-695/223,
1-17=-246/1673, 4-16=-1274/360,
7-11=-409/126, 8-11=-328/2381,
1-20=-1911/337
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) 14-9-7 to 18-4-4, Interior (1) 18-4-4
to 21-5-4, Exterior (2) 21-5-4 to 28-6-12, Interior (1)
28-6-12 to 47-5-4, Exterior (2) 47-5-4 to 51-0-0 zone;
cantilever left and right exposed ; end vertical left and
right exposed;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)This truss has been designed for greater of min roof live
load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on
overhangs non-concurrent with other live loads.
5)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
6)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members, with BCDL = 10.0psf.
7)Bearing at joint(s) 20 considers parallel to grain value
using ANSI/TPI 1 angle to grain formula. Building
designer should verify capacity of bearing surface.
8)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 366 lb uplift at joint
10 and 246 lb uplift at joint 20.
9)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
T09 Common 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:49 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:qyBeSWztOo7QdKxIddwEstyZRLd-K9GMGFV6nH2viHFzPnxifveUgL7aEv3oN154KTyZO7e
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
512
=3x6
=4x4
=4x10
=6x6
=4x4
=5x6
=4x8 =3x6
=3x4
=3x4
=3x8
=3x6
=3x4
=3x4
=3x4
=6x6
=6x8
=3x4
18
17 27 16 15 14 28 13 12 11
10
98
2620
19 7
6
51
21 4222
252423
3
T1 T2
T3
W1
W11
B3 B2 B1
W5
W3
W7
W4 W3
W6
W2
W4
W9
W10
W8
BL1
1-00-00
36-07-13
3-07-13
3-07-13
4-09-03
29-05-01
6-02-12
35-07-13
7-00-00
24-07-14
7-00-00
10-07-13
7-00-00
17-07-13
1-00-01
24-07-14
3-00-00
13-07-13
3-04-05
3-07-13
3-08
3-08
4-00-00
17-07-13
4-09-03
29-05-01
6-00-00
23-07-13
6-02-12
35-07-13
7-00-00
10-07-1311-11-003-11-061-06-008-04-103-06-06Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.93 Vert(LL)-0.17 14-16 >999 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.78 Vert(CT)-0.30 12-14 >999 240
TCDL 10.0 Rep Stress Incr YES WB 0.73 Horz(CT)0.29 10 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS Wind(LL)0.08 12-14 >999 240
BCDL 10.0 Weight: 199 lb FT = 20%
Scale = 1:65.3
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF 2100F 1.8E *Except* 12-14:2x4
SPF No.2
WEBS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
5-1-1 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
WEBS 1 Row at midpt 7-11, 7-10
REACTIONS (size)10=5-08, (min. 1-08), 13=5-08,
(min. 2-12)
Max Horiz 13=-295 (LC 10)
Max Uplift 10=-175 (LC 13), 13=-253 (LC 12)
Max Grav 10=1156 (LC 20), 13=1746 (LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 5-6=-587/186, 6-15=-633/167,
7-15=-793/155, 7-16=-267/167,
8-16=-443/145, 2-17=-191/375,
3-17=-162/581, 3-18=-722/178,
4-18=-597/190, 4-5=-578/208, 8-10=-507/213
BOT CHORD 13-19=-187/276, 19-20=-187/276,
12-20=-187/276, 11-12=-187/276,
11-21=-72/812, 21-22=-72/812,
10-22=-72/812
WEBS 7-11=-437/280, 5-11=-72/302, 3-11=-42/563,
7-10=-874/93, 2-13=-475/357,
3-13=-1546/367
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) -1-0-0 to 2-0-0, Interior (1) 2-0-0 to
9-2-0, Exterior (2) 9-2-0 to 15-2-0, Interior (1) 15-2-0 to
22-4-0, Exterior (2) 22-4-0 to 25-4-0 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-
C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)This truss has been designed for greater of min roof live
load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on
overhangs non-concurrent with other live loads.
5)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
6)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members, with BCDL = 10.0psf.
7)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 175 lb uplift at joint
10 and 253 lb uplift at joint 13.
8)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
T010 Common 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:50 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:5sKZoF685zPYM_pzcdONkPyZR3M-pLpkUbWkYaAmJQq9yVSxC7Bh1lWHzKsychqdtvyZO7d
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
812
=2x4
=6x6
=4x4
=3x4
=3x4
=4x8 =4x4
=3x8
=4x8
=4x4
=5x8 =3x8
14
13 19 2012 11 21 22
10
91
82
1617
73
1518
64
5
T2
T1
T2
T1
W1 W1
B2 B1
W4
W5
W4 W6
W2
W3
1-00-00
25-04-00
1-00-00
-1-00-00
5-11-04
12-02-00
5-11-04
18-01-04
6-02-12
6-02-12
6-02-12
24-04-00
2-12
4-06-12
4-04-00
4-04-00
7-07-04
12-02-00
12-02-00
24-04-001-09-009-10-05Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.82 Vert(LL)-0.41 10-11 >578 360 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.62 Vert(CT)-0.82 10-11 >288 240
TCDL 10.0 Rep Stress Incr YES WB 0.89 Horz(CT)0.01 10 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS Wind(LL)-0.02 11-13 >999 240
BCDL 10.0 Weight: 116 lb FT = 20%
Scale = 1:53.5
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
10-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
REACTIONS All bearings 22-08-02.
(lb) -Max Horiz 1=-198 (LC 8)
Max Uplift All uplift 100 (lb) or less at joint(s)
1, 7, 18 except 8=-143 (LC 13),
10=-183 (LC 13), 12=-180 (LC 12),
13=-151 (LC 12)
Max Grav All reactions 250 (lb) or less at joint
(s) 1 except 8=452 (LC 1), 10=526
(LC 19), 11=779 (LC 21), 12=550
(LC 18), 13=414 (LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 1-19=-151/407, 2-19=-141/420, 2-3=-90/406,
4-20=-28/394, 4-21=-27/391, 5-6=0/375,
6-22=-53/354, 7-22=-64/337
WEBS 4-11=-611/0, 3-12=-473/222, 2-13=-321/177,
5-10=-461/223, 6-8=-339/174
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) 0-5-12 to 3-4-7, Interior (1) 3-4-7 to
8-4-7, Exterior (2) 8-4-7 to 14-4-7, Interior (1) 14-4-7 to
19-8-8, Exterior (2) 19-8-8 to 22-8-8 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-
C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)All plates are 2x4 MT20 unless otherwise indicated.
5)Gable requires continuous bottom chord bearing.
6)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
7)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members, with BCDL = 10.0psf.
8)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 100 lb uplift at joint
(s) 1 except (jt=lb) 12=179, 13=151, 10=183, 8=142.
9)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
V01 Valley 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:50 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:oSTJVKxC41T?JCjhb0OGuDyZSVF-pLpkUbWkYaAmJQq9yVSxC7BovldWzPuychqdtvyZO7d
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
812
=3x4 =4x4
=3x4 =3x4
71
13 12 11 10 9 8
19 2262
5323242120
4
T1 T1
B1 B2
ST3
ST2
ST1
ST2
ST1
5-03
22-08-02
10-10-14
22-02-15
11-04-01
11-04-01
22-08-027-06-150-047-03-04Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.38 Vert(LL)n/a -n/a 999 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.16 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.56 Horiz(TL)-0.01 7 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS
BCDL 10.0 Weight: 78 lb FT = 20%
Scale = 1:49.9
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
REACTIONS All bearings 20-02-02.
(lb) -Max Horiz 1=-176 (LC 8)
Max Uplift All uplift 100 (lb) or less at joint(s)
1, 7, 18 except 8=-104 (LC 13),
9=-192 (LC 13), 12=-183 (LC 12),
13=-130 (LC 12)
Max Grav All reactions 250 (lb) or less at joint
(s) 1 except 8=404 (LC 1), 9=524
(LC 19), 11=619 (LC 24), 12=546
(LC 18), 13=359 (LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 1-2=-168/265, 3-25=-98/261, 4-21=-114/258
WEBS 4-11=-414/6, 3-12=-463/223, 2-13=-301/171,
5-9=-452/227, 6-8=-316/158
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) 0-5-12 to 3-5-12, Interior (1) 3-5-12
to 7-1-7, Exterior (2) 7-1-7 to 13-1-7, Interior (1) 13-1-7
to 17-2-8, Exterior (2) 17-2-8 to 20-2-8 zone; cantilever
left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)All plates are 2x4 MT20 unless otherwise indicated.
5)Gable requires continuous bottom chord bearing.
6)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
7)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members, with BCDL = 10.0psf.
8)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 100 lb uplift at joint
(s) 1 except (jt=lb) 12=183, 13=129, 9=192, 8=103.
9)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
V02 Valley 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:50 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:RlCr0Q4kFjzIl2e?IXb4NlyZSV3-pLpkUbWkYaAmJQq9yVSxC7BoZldYzT2ychqdtvyZO7d
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
812
=3x4 =4x4
=3x4 =3x4
71
13 12 11 10 9 8
62
19 242526
53
20 232122
4
T1 T1
B1 B2
ST3
ST2
ST1
ST2
ST1
5-03
20-02-02
9-07-14
19-08-15
10-01-01
10-01-01
20-02-026-08-150-046-05-04Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.34 Vert(LL)n/a -n/a 999 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.16 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.30 Horiz(TL)0.00 7 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS
BCDL 10.0 Weight: 66 lb FT = 20%
Scale = 1:47.1
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
10-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
REACTIONS All bearings 17-08-02.
(lb) -Max Horiz 1=-153 (LC 8)
Max Uplift All uplift 100 (lb) or less at joint(s)
5, 14 except 1=-125 (LC 19),
6=-208 (LC 13), 9=-210 (LC 12)
Max Grav All reactions 250 (lb) or less at joint
(s) 1, 5, 14 except 6=612 (LC 19),
8=824 (LC 21), 9=602 (LC 18)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 1-15=-108/423, 15-22=-96/451,
2-22=-88/543, 2-16=0/374, 3-16=0/507,
3-17=0/522, 4-17=0/325, 4-21=-64/545,
18-21=-72/453, 5-18=-83/423
BOT CHORD 1-9=-352/126, 9-19=-352/126,
8-19=-352/126, 8-20=-352/126,
7-20=-352/126, 6-7=-352/126, 5-6=-352/126
WEBS 3-8=-768/28, 2-9=-474/232, 4-6=-480/233
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) 0-5-12 to 3-5-12, Interior (1) 3-5-12
to 5-10-7, Exterior (2) 5-10-7 to 11-10-7, Interior (1)
11-10-7 to 14-8-8, Exterior (2) 14-8-8 to 17-8-8 zone;
cantilever left and right exposed ; end vertical left and
right exposed;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)Gable requires continuous bottom chord bearing.
5)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
6)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members, with BCDL = 10.0psf.
7)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 124 lb uplift at joint
1, 209 lb uplift at joint 9 and 208 lb uplift at joint 6.
8)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
V03 Valley 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:51 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:GB5XrIM9rot10auQ8sWTpbyZSUi-HXN6hxXMJuIdxaPLWCzAkKjx88zEiuO5rLaBPMyZO7c
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
812
=3x4 =2x4 =2x4 =4x4
=2x4 =3x4
=2x4 =2x4
=3x4
51
9 19 8 20 7 6
15 182221
42
1716
3
T1 T1
B1 B2
ST2
ST1 ST1
5-03
17-08-02
8-04-14
17-02-15
8-10-01
8-10-01
17-08-025-10-150-045-07-04Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.48 Vert(LL)n/a -n/a 999 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.19 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.42 Horiz(TL)-0.01 14 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS
BCDL 10.0 Weight: 55 lb FT = 20%
Scale = 1:40.9
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
REACTIONS All bearings 15-02-02.
(lb) -Max Horiz 1=-131 (LC 8)
Max Uplift All uplift 100 (lb) or less at joint(s)
1, 5 except 6=-176 (LC 13), 8=-178
(LC 12)
Max Grav All reactions 250 (lb) or less at joint
(s) 1, 5 except 6=522 (LC 19),
7=402 (LC 1), 8=498 (LC 18)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
WEBS 3-7=-330/19, 2-8=-407/204, 4-6=-417/203
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) 0-5-12 to 3-7-7, Interior (1) 3-7-7 to
4-7-7, Exterior (2) 4-7-7 to 10-7-7, Interior (1) 10-7-7 to
12-2-8, Exterior (2) 12-2-8 to 15-2-8 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-
C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)Gable requires continuous bottom chord bearing.
5)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
6)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members.
7)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 100 lb uplift at joint
(s) 1, 5 except (jt=lb) 8=177, 6=176.
8)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
V04 Valley 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:51 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:Vv7xkNTojZ?lby48AFAagVyZSUZ-HXN6hxXMJuIdxaPLWCzAkKj_38_Liyu5rLaBPMyZO7c
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
812
=3x4 =2x4 =2x4 =4x4
=2x4 =2x4 =2x4
=3x4
51
8 7 6
13 18
42
17141615
3
T1 T1
B1
ST2
ST1 ST1
5-03
15-02-02
7-01-14
14-08-15
7-07-01
7-07-01
15-02-025-00-150-044-09-04Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.29 Vert(LL)n/a -n/a 999 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.12 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.13 Horiz(TL)0.00 5 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS
BCDL 10.0 Weight: 46 lb FT = 20%
Scale = 1:37.5
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
REACTIONS All bearings 12-08-02.
(lb) -Max Horiz 1=-109 (LC 8)
Max Uplift All uplift 100 (lb) or less at joint(s) 1
except 6=-152 (LC 13), 8=-159 (LC
12)
Max Grav All reactions 250 (lb) or less at joint
(s) 1, 5 except 6=448 (LC 19),
7=365 (LC 1), 8=433 (LC 18)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
WEBS 3-7=-278/31, 2-8=-384/200, 4-6=-389/197
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) 0-5-12 to 9-4-7, Interior (1) 9-4-7 to
9-8-8, Exterior (2) 9-8-8 to 12-8-8 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-
C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)Gable requires continuous bottom chord bearing.
5)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
6)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members.
7)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 100 lb uplift at joint
(s) 1 except (jt=lb) 8=158, 6=152.
8)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
V05 Valley 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:51 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:Dqkjqob4MdGKoVr3lMMw4cyZSUP-HXN6hxXMJuIdxaPLWCzAkKj?e8_eizk5rLaBPMyZO7c
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
812
=3x4 =2x4 =2x4
=2x4 =4x4
=2x4
=2x4 =3x4
51
8 7 6
42
13 181714
1615
3
T1 T1
B1
ST2
ST1 ST1
5-03
12-08-02
5-10-14
12-02-15
6-04-01
6-04-01
12-08-024-02-150-043-11-04Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.26 Vert(LL)n/a -n/a 999 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.10 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.08 Horiz(TL)0.00 5 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS
BCDL 10.0 Weight: 37 lb FT = 20%
Scale = 1:33.8
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
10-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
REACTIONS (size)1=10-02-02, (min. 1-11),
3=10-02-02, (min. 1-11),
4=10-02-02, (min. 1-11)
Max Horiz 1=-86 (LC 8)
Max Uplift 1=-47 (LC 19), 3=-8 (LC 12),
4=-150 (LC 13)
Max Grav 1=177 (LC 18), 3=123 (LC 1),
4=863 (LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 1-9=-79/263, 2-9=-43/328, 2-10=-68/384,
3-10=-82/263
WEBS 2-4=-649/191
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for
members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)Gable requires continuous bottom chord bearing.
5)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
6)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members.
7)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 47 lb uplift at joint
1, 8 lb uplift at joint 3 and 150 lb uplift at joint 4.
8)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
V06 Valley 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:51 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:_NDlWXh5U5HCljScD1VoPIyZSUH-HXN6hxXMJuIdxaPLWCzAkKjzk8wkiz_5rLaBPMyZO7c
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
812
=3x4 =4x6
=2x4 =3x4
31
4
109
2
T1 T1
B1
ST1
5-03
10-02-02
4-07-14
9-08-15
5-01-01
5-01-01
10-02-023-04-150-043-01-04Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.38 Vert(LL)n/a -n/a 999 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.35 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.13 Horiz(TL)0.00 3 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS
BCDL 10.0 Weight: 28 lb FT = 20%
Scale = 1:31.4
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
7-8-2 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
REACTIONS (size)1=7-08-02, (min. 1-08), 3=7-08-02,
(min. 1-08), 4=7-08-02, (min. 1-08)
Max Horiz 1=-64 (LC 8)
Max Uplift 1=-21 (LC 12), 3=-13 (LC 13),
4=-97 (LC 13)
Max Grav 1=128 (LC 18), 3=111 (LC 1),
4=612 (LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
WEBS 2-4=-421/122
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for
members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)Gable requires continuous bottom chord bearing.
5)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
6)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members.
7)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 21 lb uplift at joint
1, 13 lb uplift at joint 3 and 97 lb uplift at joint 4.
8)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
V07 Valley 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:51 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:oXa0nams3x1LTewlaIcCeZyZSUB-HXN6hxXMJuIdxaPLWCzAkKj?48yci__5rLaBPMyZO7c
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
812
=3x4 =4x4
=2x4 =3x4
31
4
109
2
T1 T1
B1
ST1
5-03
7-08-02
3-04-14
7-02-15
3-10-01
3-10-01
7-08-022-06-150-042-03-04Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.23 Vert(LL)n/a -n/a 999 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.23 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.06 Horiz(TL)0.00 3 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MP
BCDL 10.0 Weight: 20 lb FT = 20%
Scale = 1:29.9
PRELI
MI
N
A
R
Y
LUMBER
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
OTHERS 2x4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or
5-2-2 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
bracing.
REACTIONS (size)1=5-02-02, (min. 1-08), 3=5-02-02,
(min. 1-08), 4=5-02-02, (min. 1-08)
Max Horiz 1=-42 (LC 8)
Max Uplift 1=-15 (LC 12), 3=-17 (LC 13),
4=-49 (LC 13)
Max Grav 1=85 (LC 18), 3=94 (LC 1), 4=366
(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
NOTES
1)Wind: ASCE 7-10; Vult=117mph (3-second gust)
Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.
II; Exp C; Enclosed; MWFRS (envelope) exterior zone
and C-C Exterior (2) zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for
members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category
II; Exp C; Partially Exp.; Ct=1.10
3)Unbalanced snow loads have been considered for this
design.
4)Gable requires continuous bottom chord bearing.
5)This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
6)* This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members.
7)Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 15 lb uplift at joint
1, 17 lb uplift at joint 3 and 49 lb uplift at joint 4.
8)This truss is designed in accordance with the 2015
International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply 152-154 South Main Street, Northampton
V08 Valley 2 124090806BR Job Reference (optional)
UFP Site Built, LLC, UFP SE Engineering Run: 8.73 S Jul 24 2024 Print: 8.730 S Jul 24 2024 MiTek Industries, Inc. Fri Sep 27 16:39:52 Page: 1
This is a PRELIMINARY drawing; web configuration
and lumber could change at the time of production.
ID:5tVfFzrFQ4vMpjy6UGErQ1yZSU4-lkxUvGX_4CQTZk_Y4vUPHYGC5YKuRRkF4?JkxoyZO7b
This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component
is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing
codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is
fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for
general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute.
8 12
=2x4 =4x4
=2x4 =2x4
3
1
4
9 10
2
T1 T1
B1
ST1
5-03
5-02-02
2-01-14
4-08-15
2-07-01
2-07-01
5-02-021-08-150-041-05-04Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 35.0 Plate Grip DOL 1.15 TC 0.08 Vert(LL)n/a -n/a 999 MT20 197/144
(Roof Snow = 35.0)Lumber DOL 1.15 BC 0.10 Vert(TL)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.03 Horiz(TL)0.00 3 n/a n/a
BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MP
BCDL 10.0 Weight: 13 lb FT = 20%