Loading...
42-035 (7) BP-2024-1278 735 WESTHAMPTON RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 42-035-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2024-1278 PERMISSION IS HEREBY GRANTED TO: Project# 2024 SOLAR Contractor: License: SUNRUN INSTALLATION SERVICES Est.Cost: 27748 INC CS-090170 Const.Class: Exp.Date:05/09/2026 TIETJEN,CARL DOUGLAS &WEAVER, JASON Use Group: Owner: TROY Lot Size (sq.ft.) Zoning: WSP Applicant: SUNRUN INSTALLATION SERVICES INC Applicant Address Phone: Insurance: 240A CHERRY ST 413-259-8044 WC614287603 SHREWSBURY, MA 01545 ISSUED ON: 10/02/2024 TO PERFORM THE FOLLOWING WORK: INSTALL 36 PANEL 14.76 KW ROOF MOUNT SOLAR SYSTEM (RAFTER ATTACHED, NO STRUCTURAL UPGRADES OR BATTERY) POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: / aP Fees Paid: $125.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner The Commonwealth of Masstchusletts FOR 'k'. Board of Building Regulations and Standaaer 1 ` MU ICIPALITY Massachusetts State Building Code, 780 CMR 2024 USE Building ermit Application To Construct, R air;}fteti : - • Demolish a Re ised Mar 2011 aor-l-nctrn One-or Two-Family ,., / ,,m•C:7tnro9 This Sec ion For Official Use Only ' Building Permit Number: 9 r%.4 q' /a7 5 Date Applied: Building Official(Print Name) Si re Date SECTION 1: SITE INFORMATION TOOhaYV kOn 1- , 1.2 Assessors Map& Parcel Numbers l.la Is this an accepted street. yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40.§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: _ Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' Nyr)vynei2.1.4,et�e,) OorThmp+on, Name(Print) City,State,ZIP & ho f on Qd_ oil-697-7U No.and Street Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg. ❑ Number of Units Other liY Specify: Solar Installation • f Description of Propo ed Work`: p -it ; • is odul are CL -pi oneerJQ ef4e,,nrti rUosc2v1 SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1. Building $5S fi,76 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $/41 J9 0 Standard City/Town Application Fee 2.Electrical $005 / 0 Total Project Cost3(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All FFe0 Check N Check Amount: LX Cash Amount: 6.Total Project Cost: $a7 J 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-090170 05/09/2026 Robert J Decker IV. IV License Number Expiration Date Name of CSL Holder List CSL Type(see below) U 240a Cherry St, Shrewsbury, MA 01545 • No.and Street Type Description . - U Unrestricted(Buildings up to 35,000 cu.ft.) Chicopee, MA 01022 R - Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC , Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 413-259-8044 pioneervalleypermits©sunrun.com I Insulation Telephone Email address D i Demolition 5.2 Registered Home Improvement Contractor(HIC) t 180120 ; 10/13/2026 Sunrun Installation Services Inc HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 225 Bush St Suite 1400 pioneervalleypermits©sunrun.com No.and Street Email address San Francisco,CA 94104 413-259-8044 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ' No 0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby autho •ze Sunrun Installation Services Inc . 1 to act on my behalf',,in all matters relative fo'wdrk aullioriied by this building permit application. • • 4 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information co •ned in this application is true and accurate to the best of my knowledge and understanding. • " - 9 ail • Pr Owner's or Authorized gent's ame(Electronic Signature) Date' NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be-found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: . . ' ' Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Costa' ,\ The Commonwealth of Massachusetts Department of Industrial Accidents 9 to, ° Office of Investigations !' ate= �, Lafayette City Center _=1�=-4111.rj,(-� 2 Avenue de Lafayette, Boston, MA 02111-1750 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Solar Installation Address: 225 Bush St Suite 1400 City/State/Zip:San Francisco, CA 94104 Phone #: 978-872-4294 Are you an employer? Check the appropriate box: Type of project (required): 1.❑ I am a employer with 4. ❑ I am a general contractor and 1 employees (full and/or part-time).* have hired the sub-contractors 6. El New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. 0 Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition workingfor me in anycapacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance. required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.0 I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' I3.2 Other Solar Installation comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: American Zurich Insurance Company Policy #or Self in�s Lic. #:WC614287603 Expiration Date: 10/1/2025 Job Site Address: /c�J tDebOxn 1 l City/State/Zip: %FA-11).mi)*P� tof Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby c tifh under the pains and penalties of perjury that the information provided above is true and correct. Signature: ���- -�--M` Date: 9/27/2024 Phone#: 559-240-9 70 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(check one): 11:1Board of Health 20 Building Department 3ECity/Town Clerk 4.0 Electrical Inspector 50Plumbing Inspector 6.❑Other Contact Person: Phone#: ® Commonwealth of Massachusetts Construction Supervisor Division of Occupational Licensure Unrestricted-Buildings of any use group which contain less than Board of Building Regulations and Standards 35,000 cubic feet(991 cubic meters)of enclosed space. Constr Rio if ttplrvisor CS-090170 _ i I tpires:05/09/2026 ROBERT J DECKER IV,IV y, 77 FEDERALST MONTAGUE OA 01349 i, _ 1111. OO 1 - ? fit LvO, , Failure to possess a current edition of the Massachusetts State Building Code is cause for revocation of this license. Commissioners : ContactOPSI:(617)727-3200orvisitwww.mass.gov/dpl/opsi Phone Number: 559-240-9370 THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration (4.x V Type: Supplement Card SUNRUN INSTALLATION SERVICES INC. Registration: 180120 27:7 Expiration: 10/13/2026 1 WORLDS FAIR DR SOMERSET, NJ 08873 === 7r Update Address and Return Card. THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs&Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE:Supplement Card Office of Consumer Affairs and Business Regulation Registration Expiration 1000 Washington Street -Suite 710 180120 10/13/2026 Boston,MA 02118 SUNRUN INSTALLATION SERVICES INC. ROBERT J DECKER IV 600 CALIFORNIA ST SUITE 1800 SAN FRANCISCO.CA 94108 Undersecretary Not vali ithout signature �...411 SUNRINC-02 TWANG ACORU CERTIFICATE OF LIABILITY INSURANCE DATE(MMroo/rWY) ` ---- 9/9/2024 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#0C36861 CONTACT NAME: Walter Tanner Alliant Insurance Services,Inc. PHONE I FAX 560 Mission St 6th Fl (A/C,No,Eat): (A/C,No): San Francisco,CA 94105 FjoAriless:Walter.Tanner@alllant.com AD INSURER(S)AFFORDING COVERAGE NAIC N INSURER A:Evanston Insurance Company 35378 INSURED INSURER B:Zurich American Insurance Company 16535 . Sunrun Installation Services,Inc INSURER C:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURERD: San Luis Obispo,CA 93401 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. IISR AWL SUBR POUCY EFF POUCY EXP LTR TYPE OF INSURANCE NISD NMI POLICY NUMBER IMM/DD/YYYYI IMMIDD/YYM UNITS A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE X OCCUR MKLV5ENV104843 10/1/2024 10/1/2025 PREM ES MMACgE TO NEa RENTED ) $ 1,000,000 ocwrrertce MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMITR APPLIES PER: GENERAL AGGREGATE $ 2,000,000 Al POLICY X JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 X I OTHER:Retention:$200,000 Per Project Agg $ 5,000,000 B AUTOMOBILE UABIUTY [[EaMac cide nISINGLE LIMIT $ 2,000,000 X ANY AA�U��TO _ 'BAP614287703 10/1/2024 10/1/2025 BODILY INJURY(Per person) $ AUTOSUT ONLY AAUUTNOSSWyytL�E�Dp BODILY INJURY(Per accident) $ A ONLY ^ AUTOS ONLY PRO pR�rn?AMAGE $ X 'Fip - X Cal Naeovefed Liability Ded.: $ 1,000,000 UMBRELLA UAB OCCUR EACH OCCURRENCE $ EXCESS LIAB ~CLAIMS-MADE AGGREGATE $ DEO RETENTIONS $ - C WORKERS COMPENSATIONOT AND EMPLOYERS'LIABILITYX MUTE ERµ Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE WC814287803 10l1/2024 10/1/2025E.L.EACH ACCIDENT $ 1,000,000i ICEitopyr5n B5Rj EXCLUDED N N/A 1,000,000 E L.DISEASE-EA EMPLOYEE $ If yyes descnbe under 1,000.000 DESG�RIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS!LOCATIONS!VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Workers'Compensation Policy WC614287603 Deductible:$1,000,000. Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE City of Northampton THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN tYP ACCORDANCE WITH THE POLICY PROVISIONS. 212 Main St Northampton,MA 01060 - AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD =' EV projects@evengineersnet.com 276-220-0064 lii, ENGINEERS http://www.evengineersnet.com 9/28/2024 RE:Structural Certification for Installation of Residential Solar CARL TIETJEN:735 WESTHAMPTON RD, NORTHAMPTON, MA,01062 Attn:To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report,the roof is made of Composite shingle roofing over roof plywood supported by SPF#2 2X6 Rafters at 16 inches with a 13.3 feet max span. The slope of the roof was approximated to be 17, 18, 26, and 41 degrees. After review and based on our structural capacity calculation,the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades.Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies,a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. Design Criteria Code 2015 IRC (ASCE 7-10)-CMR 780 9th Ed Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 117 mph PV Dead Load DPV 3 psf Exposure B Roof Live Load Lr 20 psf Ground Snow S 40 psf If you have any questions on the above, please do not hesitate to call. STRUCT ;.. Sincerely, ��FA�tH OFMQSSgc o 4, �4- VINCENT Gr Vincent Mwumvaneza, P.E. MWUMVANEZA N Signed:9/28/2024 EV Engineering, LLC N,CIVIL 2 proiects@evengineersnet.com di y/ ago sQ http://www.evengineersnet.com �•�. pNA�EN�\� 1/1 . EV projects@evengineersnet.com 276-220-0064 won ENGINEERS http://www.evengineersnet.com Structural Letter for PV Installation 9/28/2024 Job Address: 735 WESTHAMPTON RD NORTHAMPTON, MA,01062 Job Name: CARL TIETJEN Job Number: 240928CT Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing.All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet 1 Cover 2 Attachment checks 3 Snow and Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 40 psf Wind Load (component and Cladding) V 117 mph Exposure B References NDS for Wood Construction STRUCT � . ONL oN OF MAssgo Sincerely, �4' VINCENT szP 0 MWUMVANEZA CIVIL Vincent Mwumvaneza, P.E. i q- EV Engineering, LLC •:�•; • Eat' ��a`�`` proiects@evengineersnet.com '� ONAlE�6 http://www.evengineersnet.com 1/1 MOM 'E projects@evengineersnet.com 276-220-0064 MIMI ENGINEERS http://www.evengineersnet.com Wind Load Cont. Risk Category= II ASCE 7-10 Table 1.5-1 Wind Speed (3s gust),V= 117 mph ASCE 7-10 Figure 26.5-1A Roughness= B ASCE 7-10 Sec 26.7.2 Exposure= B ASCE 7-10 Sec 26.7.3 Topographic Factor, Kzu= 1.00 ASCE 7-10 Sec 26.8.2 Pitch = 26.0 Degrees Adjustment Factor, A= 1 ASCE 7-10 Figure 30.5-1 a = 3.60 ft ASCE 7-10 Figure 30.5-1 Where a:10%of least horizontal dimension or 0.4h,whichever is smaller,but not less than 4%of least horizontal dimension or 3ft(0.9m) Uplift(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= -20.5 -28.8 -45.5 Figure 30.5-1 Pnet=0.6 x A x KZT x Pnet30)= 12.29 17.31 27.29 Equation 30.5-1 Downoressure(0.6W1 Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= 11.0 11.0 11.0 Figure 30.5-1 Pnet=0.6 x A x KZT x Pnet30)= 6.58 6.58 6.58 Equation 30.5-1 Rafter Attachments:0.6D+0.6W(CD=1.6) Connection Check Attachment max. spacing= 5.3 ft 266 Ibs/in Manufacturer Test Lag Screw Penetration 2.5 in Prying Coefficient 1.4 Allowable Capacity= 512 Ibs 0.6D+0.6W Dpv+0.6W Zone Trib Width Area(ft) Uplift(Ibs) Down(Ibs) 1 5.3 17.2 180.6 165.1 2 5.3 8.6 133.6 82.5 3 2 3.3 82.8 31.1 Max= 180.6 < 512 CONNECTION IS OK 1. Pv seismic dead weight is negligible to result in significant seismic uplift,therefore the wind uplift governs 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. 1/1 =V EV projects@evengineersnet.com 276-220-0064 lima ENGINEERS http://www.evengineersnet.com Vertical Load Resisting System Design Roof Framing Pg= 40 psf ASCE 7-10,Section 7.2 pf= 28 psf Ce= 0.9 ASCE 7-10,Table 7-2 Pfmin.= 35.0 psf Ct= 1.1 ASCE 7-10,Table 7-3 ps= 35 psf 34.2 plf Is= 1.0 ASCE 7-10,Table 1.5-1 CS 0.733 Max Length,L= 13.3 ft Tributary Width,WT= 16 in Dr= 10 psf 13.33 plf PvDL= 3 psf 4 plf Load Case:DL+0.6W Pnet+Ppvcos(8)+PDt= 26.1 plf Max Moment, Mu= 411 lb-ft Conservatively Pv max Shear 82.5 lbs Max Shear,V„=wL/2+Pv Point Load = 197 lbs Load Case:DL+0.75(0.6W+S)) 0.75(Pnet+Ps)+PpVcos(0)+PDT= 49 plf Mdown= 775 lb-ft Mallowable=Sx x Fb'(wind)= 1319 lb-ft > 775 lb-ft OK Load Case:DL+S Ps+Ppvcos(0)+Ppt= 51 plf Mdown= 806 lb-ft Mallowable=Sx x Fb'(wind)= 948 lb-ft > 806 lb-ft OK Max Shear,V„=wL/2+Pv Point Load = 339 lbs Member Capacity SPF#1/#2 2X6 Design Value CL CF C, Cr Adjusted Value Fb= 875 psi 1.0 1.3 1.0 1.15 1308 psi F„= 135 psi N/A N/A 1.0 N/A 135 psi E= 1400000 psi N/A N/A 1.0 N/A 1400000 psi Depth,d = 5.5 in Width, b= 1.5 in Cross-Sectonal Area,A= 8.25 in2 Moment of Inertia, IXX= 20.7969 in4 Section Modulus,S.= 7.5625 in3 Allowable Moment, Mail= Fb'SXX= 824.4 lb-ft DCR=M„/Mai,= 0.81 <1 Satisfactory Allowable Shear,Vali=2/3Fv'A= 742.5 lb DCR=V„/Vail= 0.30 < 1 Satisfactory 1/1 projects@evengineersnet.com 276-220-0064 mom ENGINEERS http://www.evengineersnet.com Siesmic Loads Check Roof Dead Load 10 psf %or Roof with Pv 18.2% Dpv and Racking 3 psf Averarage Total Dead Load 10.5 psf Increase in Dead Load 2.2% OK The increase in seismic Dead weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scoae of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans -CARL TIETJEN.The analysis was according to applicable building codes,professional engineering and design experience,opinions and judgments.The calculations produced for this structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. 1/1 SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE a DESCRIPTION roil •SYSTEM SIZE 14760W DC 10000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC4BC/IEBC).7.10 PV-1.0 COVER SHEET SERVICE ENTRANCE •MODULES(38)HANWHA Q•CELLS 0 PEAK DUO BLK ASCE&2015 NDS,2023 NEC AND 2023 MA ELECTRICAL CODE 527 CMR 12.00(2023 PV-2.0 SITE PLAN � � ML-G10+410 NFPA 70 WTN MA AMENDMENTS),MUNICIPAL CODE AND ALL MANUFACTURERS �, MAIN PANEL •INVERTERS:(1)SOLAREDGE TECHNOLOGIES LISTINGS AND INSTALLATION INSTRUCTIONS. PV-3.0 LAYOUT SE10000H-USMN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP TO PV•4.0 ELECTRICAL SP SUB-PANEL FRAMING,SEE DETAIL SNR•DC-00438 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WTH NEC 2023. PV•50 SIGNAGE •PHOTOVOLTAIC SYSTEM IS UNGROUNDED NO CONDUCTORS ARE SOLIDLY LC PV LOAD CENTER GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 890 35 SM SUNRUN METER •MODULES CONFORM TO AND ARE USTED UNDER UL 81730 1 •INVERTER CONFORMS TO AND IS USTED UNDER UL 1741 PM DEDICATED PV METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. iNV INVERTER(S) •SNAPNRACK RACKING SYSTEMS.IN COMBINATION WITH TYPE, OR TYPE,, MODULES.ARE CLASS A FIRE RATED Li. AC DISCONNECT(S) •RAPID SHUTDOWN REQUIREMENTS NET WHEN INVERTERS ANO ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 63012(1) I►1l DC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 890 31(D) •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. CB IQ COMBINER BOX •11 2 AMPS MODULE SHORT CIRCUIT CURRENT. INTERIOR EQUIPMENT •14 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)] ABBREVIATIONS L J SHOWN AS DASHEC •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690 12(B)(2)(2) CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE CHIMNEY LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION = su n r u n ' _ � ATTIC VENT O FLUSH ATTIC VENT . o PVC PIPE VENT -. -- 4i METAL PIPE VENT VICINITY MAP ' ® I-VENT o 1) SATELLITE DISH CUSTOMER RESIDENCE CARL TIETJEN FIRE SETBACKS 735 WESTHAMPTON RD, NORTHAMPTON,MA,01062 HARDSCAPE TEL.(413)834-5535 :' - APN.NHAM-000042-000035.000001 -PL- PROPERTY LINE PROJECT NUMBER: °` SCALE.NTS • 224R•735TIET DESIGNER: (415)580-6920 ex3 SOLAR MODULES FLORIEN NIYONKURU �MI� T,r SHEET REV NAME DATE COMMENTS COVER SHEET _ MI h i REV.A 9/27/2024 «,::.:::-E SNR_MOUNT n;: r-' A r SNR MOUNT&SKIRT PAGE PV-1.O ARRAY TRUE MAG PV AREA SITE PLAN-SCALE=1/16"=1'4' PITCH AZIM AZIM (SOFT) AR-01 26• 351- 365- 126.8 ICI AR•02 41 81' 95' 1268— (N)ARRAY AR-05 AR-03 41' 261' 275' 169.1 AR-04 18 205- 219 126 8 7 — tt AR-05 17 170' 184` 63 4 _ _ P. AR-06 18 25 39- 147.9 \------- (N)ARRAY AR-06 ROOF PATHWAYS-- % (3'TYP) (N)ARRAY AR-05 (E)RESIDENCE .7,1 r , - i. 4t- , FIRE SETBACKS 11S _, , , _ (18°TYP) , - •..4 (N)ARRAY AR-01 - wiraga (N)ARRAY AR•04 ROOF PATHWAYS I1��I �' (3'TYP) ��`t'� ---- (t.)ARRAY AR-02 (N)ARRAY AR-03 1,t, � ' =t, � _ ` 01 sunrun :c. ., IllipsW - #180120 w. Oh .\:... (E)DRIVEWAY ,,,,`' • CUSTOMER RESIDENCE CARL TIETJEN 735 WESTHAMPTON RD, • NORTHAMPTON.MA,01062 ?,.. TEL(413)8345535 APP.!'NHAM-000042-000035-000001 NOTES: • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE r'. WE MpTO----ii:.....• N RD PROJECT NUMBER SPRINKLERS STHA 224R-735TIET DESIGNER' 1415)580-6920 ex3 ARRAY DETAILS: • TOTAL ROOF SURFACE AREA.4190 SOFT. FLORIEN NIYONKURU • TOTAL PV ARRAY AREA 760.8 SQ FT. SHEET • PERCENTAGE PV COVERAGE' SITE PLAN (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA)•100=18.296 REV A 9/27/2024 PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF 9 SNOW LOAD:40 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang WIND SPEED: RL UNIVERSAL SPEEDSEAL TRACK ON COMP TO 117 MPH 3-SEC GUST. AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 13'-3" 16" FRAMING,SEE DETAIL SNR-DC-00436 5-4" 2-1" 4'-0" 1'-8" STAGGERED S.S.LAG SCREW 5r16'k5.5":2.5"MIN.EMBEDMENT AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS T-7' 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP TO 5•4" 2-1" 4'-0" 2-0' STAGGERED FRAMING,SEE DETAIL SNR-DC-00436 AR-03 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS T-T• 16' RL UNIVERSAL SPEEDSEAL TRACK ON COMP TO 5-4" 2-1" 4.-0" 2-0' STAGGERED FRAMING,SEE DETAIL SNR-DC-00436 STRUCT,; AR-04 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10.-5" 16" RL UNIVERSAL,FRAMINGSSEE DETAIL SNR DPEEDSEAL TRACK o-0OOMPTO 5'-4" 2-1" NA NA STAGGERED OML a�w}1NOF4yI4 VINCENT c RL UNIVERSAL SPEEDSEAL TRACK ON COMP TO 1 AR-05 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-6' 16" FRAMING,SEE DETAIL SNR-DC 00436 5'-4" 2-1" NA NA STAGGERED MWUMVANQA CIVIL RL UNIVERSAL SPEEDSEAL TRACK ON COMP TO AR-06 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10.6' 16" FRAMING,SEE DETAIL SNR•DC-DC B-4" 2-1" NA NA STAGGERED .,Eik.0 e`e '.4? ONAIEl'G` D1-AR-01-SCALE:1/8"=1'-0" D2-AR-02-SCALE:3/32"=1'-0 D3-AR-03-SCALE:3132'=1'-0" AZIM:351` AZIM:81' A: 261' Signed 928f2024PITCHfi2@"-11'$" -6-2'- 3- 1"{- PITCH'41° 24'-10" -.-T-9"-I �1'-T {' 14'S" (�ul// PITCH:41' tT ---o = 1'8" 3 � ` / 611" } 1 T 4" 24'10" 15'11" 8 8• 5'-4"TYPT-1 J 5-4"TYP 3'-11"Jl \ ( _ n // II ���� ° Air IIIII 13-11 I / STRUCTURAL NOTES. ..•4'6 — 12'-9'- 4'-T'{ 2 T INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES A/ I 8-11 - - OBSERVED PRIOR TO PROCEEDING W/INSTALLATION. • IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" -T-9"-1 BOUNDARY REGION OF ANY ROOF s u n r u n 6.17 NEEDPLANE EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS TO BE ADDEDAND 2.5" ••OVERHANG REDUCED WITHIN THE 12"ALLOWAB E ATTACHMENT SPACING INDICATERY REGION ONLY AS D ON PLANS TO BE REDUCED BY 2-2' -5'-5" _ 125' 6 1 r' 5096. •• ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE #180120 ATTACHMENT SPACING INDICATED ON PLANS. 'C PAEKYTIE STUNT.0*COPEE.MA_01012.Ia5 D4-AR-04-SCALE:1/8"=1'-0" D5-AR-05-SCALE:1/8"=1'-0" D6-AR-06-SCALE:1/8"=1'-0" 4,4° AZIM:205' AZIM:170` AZIM:25` PITCH.18' -T-1" -- 15-8" .3'-2' PITCH:1T }3'-10 17-5" -5-2'-� PITCH:18° CUSTOMER RESIDENCE: CARL TIETJEN 4'-4"1 5,-4"TYP 6-_ 18•$" —T { 735 VVESTHAMPTON RD, WA1rarAlinA 1'`6" / " I NORTHAMPTON,MA,01062 I i _ 3'-6" 3'T-8_5• I I� / TEE.(413)834.5535 3' I -T 'i -. : 3'-5"6.11" I/ T " 1 /T, 224R.735TIET 3$. ---,- 1. ... DESIGNER: (415)580-6920ez3 I ' FLORIEN NIYONKURU �A I SHEET 5"-,r- 1'-2"-i -6-2"-'-4'-8"-} LAYOUT 24%10" -4'-11"-I REV:A 9/27/2024 1'-8"- PAGE PV-3.0 C POINT OF INTERCONNECTION 705.I I(A)(2) J HANWHA Q-CELLS SUPPLY SIDE TAP Q.PEAK DUO BLK �METERNUMBER 9590198 ML-G10+410 J {N) • LOCKABLE EQUIPMENT CHARACTERISTICS BL STRING 3 OF 9 MODULES ADE TYPE FUSED INCLUDED IN SPEC SHEETS (WITH S440 OPTIMIZERS) AC DISCONNECT NOTE:TOTAL PV BACKFEED EXISTING 200A I =52.5A USED FOR INTERCONNECTION CALCULATIONS 1 — — MAIN BREAKER db HANWHA Q CELLS END FED Q.PEAK DUO BLK EXISTING 200A _ ML-G10+410 MAIN PANEL SOLAREDGE I STRING 2 OF 13 MODULES 200A BUS SE10000H-USMN - (WITH$440 OPTIMIZERS) 10000 WATT 111 INVERTER T _ { HANWHA Q-CELLS Q PEAK DUO BLK _ J ML-G10+410 o—f o _ STRING 1 OF 14 MODULES 0 0 1. ' /v o�'0 — (WITH S440 OPTIMIZERS) SQUARE D LOAD RATED DC JUNCTION D222NRB, DISCONNECT WITH BOX 3R,60A,2P AFC]RAPID 120/240VAC SHUTDOWN 60A FUSES COMPLIANT CONDUIT SCHEDULE GENERAL NOTES: $u n ru n • TAP DEVICE MUST BE MARKED"SUITABLE FOR USE ON THE LINE SIDE OF TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT THE SERVICE EQUIPMENT"OR EQUIVALENT 1 Inverter Input (2)10 AW G (PV WIRE) N/A 10 AWG(BARE) Open Air 2 Inverter Input (6)10 AWG N/A 10 AWG THHN/THWN-2 3/4 EMT #180120 THHN/THWN-2 3 Inverter Output (2)6 AWG (1)10 AVVG 8 AWG THHN/THWN-2 3/4 EMT v" THHN/THWN-2 THHNITHWN-2 4 Inverter Output ER RE (2)6 AWG (1)8 AWG 8 AVtG THHN/THVVN-2 1 EMT CCARLOTIETJENSIDE E THHN/THWN-2 THHN/THWN-2 735 WESTHAMPTON RD, NORTHAMPTON,MA,01062 MODULE CHARACTERISTICS TEL.(413)834-5535 HANWHA Q-CELLS:Q.PEAK DUO BLK APN:NHAM•000042-000035-000001 ML-G10+410: 410 W PROJECT NUMBER OPEN CIRCUIT VOLTAGE 45 37 V 224R•735TIET MAX POWER VOLTAGE 37.64 V SHORT CIRCUIT CURRENT: 11.2 A DESIGNER (415)580.6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 FLORIEN NIYONKURU SYSTEM SIZE: 14760 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE 14 V ELECTRICAL MAX ALLOWABLE DC VOLTAGE 48C V SYSTEM SHORT CIRCUIT CURRENT: 36 A REV:A 9/27/2024 PAGE PV-4.0 A, . ARNIN INVERTER I NOTES AND SPECIFICATIONS' •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B).UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690.OR ELECTRICAL SHOCK HAZARD - IF REQUESTED BY THE LOCAL AHJ- MAXIMUM SYSTEM VOLTAGE CM VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS.COLORS AND SYMBOLS. SIDES MAYBE ENERC�+I7FD IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING l ABEL LOCATION. METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(5).DC DISCONNECT($). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(5)NEC 2023.690.7(0) INVOLVED. LABEL LOCATION •SKINS AND LABELS SHALL COMPLY WITH ANSI Z535 4.2011,PRODUCT SAFETY INVERTER(S).ACIDC DISCONNECT(S). SIGNS AND LABELS.UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE) •DO NOT COVER EXISTING MANUFACTURER LABELS PER CODE(S)NEC 2023'690 13(B). 705 20(7),706.15(C) A ,'ARNIN DUAL POWER SUPPLY SOURCES:UTILITY GRID WARNING: PHOTOVOLTAIC AND PV SOLAR ELECTRIC POWER SOURCE SYSTEM LABEL LOCATION LABDC CONDUIT EVERY 10 FT. UTIL LITY SERVICE METER AND MAN AT EACH TURN.ATION. INTERIOR AND EXTBOVE AND BELOW PENETRATIONS, CAUTION . SERVICE PANEL ON EVERY JBIPULL BOX CONTAIN NG DC CIRCUITS. PER CODE(S).NEC 2023 705 3C,C'' PER CODE(S)NEC 2023.690 3110X21 ■ - ! ARN1NG RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS SOLAR PANELS \ OVERCURRENT DEVICE PON ROOF LABEL LOCATION "1 `/ LOCATION ON INSTALLED WITHIN I OF RAPID .SHUT DOWN sunrun ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE15).NEC 2023.690.12(DX21.IFC �OCPD(IF APPLICABLE). :018 120453 LIT{-1 PER CODE(S).NEC 2023.705.12(B)(2) Mk Irk • r SERVICE 1 +2<�,,-.. SOLAR PV SYSTEM EQUIPPED 01`L 1.833.607.6937 ext. 0 WITH RAPID SHUTDOWN ENTRANCE® 1.855 478 6786 CUSTOMER RESIDENCE 911 �, ,,� CARL TIETJEN 735 VVESTHAMPTON RD, ,�r. a waegOM: �� NORTHAMPTON.MA,01082 s V n ru n TURN RAPID SHUTDOWN *, • SWITCH TO THE'OFF" 50••.,.,. TEL (413)834-5535 .-. LOCATION .�. POSIONTOSHUTDOWN INVERTER (EXT) APN•NHAM-000042-000035-000001 MAN SERVICE DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER- SHOCK HAZARD IN THE —AC DISCONNECT 224R-735TIET ARRAY. INVERTER (EXT) DESIGNER (415)580.8920ex3 735 WESTHAMPTON RD, NORTHAMPTON, MA. 01062 FLORIENNIYONKURU 1--` SHEET LABEL LOCATION. SIGNAGE ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICL PER CODE(S)NEC 2023.705.10(21 DISCONNECTING MEANS TO WHCH THE PV SYSTEMS ARE CONNECTED. REV-A 9/27/2024 PER CODE(S)NEC 2023.800.12(D) PAGE PV-5.0 sZ6Lb53Hns90 10:LaN ateldwal SZ:Jap=o aieldwal)VUOe71£0000009wbe auawaa.av gNyn0000000980e:pi lesodwd worunauns@ewea laapue eweJ !aJpuy anneluasaJda8 sales JnoA 41111111111.110, I IMF III VII 11°1 0 t IN I ., li i 111 W II II It MI I` MOM 7 " _ ..,. . . . . . . . . . . . . . . . . . . . Z90 LO'VW . • 'uoldweyLioN 'p2{ uoldweylsaM SEL . N31-1311121VJ uns aril Act uru iauEId 1 o4 @IITODI@M unJuns 9dO£V3d9A0a6-9068-b834-0111A-A8840£AZ:a Gd IeA 3 upsncioci Docusign Envelope ID:2F3ODB8F-FB4C-4EB4-8908-9DOFBFEA3CF6 IP Your signature below indicates that (a) you're 18 years of age or older, (b) you're the owner of legal title to the Home and that every person or entity with an ownership interest in the Home has agreed to be bound by the terms of the Agreement, (c) that you have been advised on your rights to cancel this agreement,and(d)that you have read,understood,and accepted the provisions set forth in this contract. You also understand that if you do not give us a written request on which end of term option you choose 30 days before your Agreement terminates,we will automatically renew this Agreement for 5 years. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO THE DATE WE COMMENCE CONSTRUCTION AT YOUR HOME. PLEASE REVIEW THE ATTACHED NOTICES OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. Do not sign this contract if there are any blank spaces. Signed by: Agreed and accepted by: —,VC2Agreed and accepted by \---E7F8EABE86C8422 _ (Second Signer,optional): Print Name: Carl Tietjen Print Name (Second signer,optional): Date: 9/11/2024 Signed by: $caned by: Sales Co>rt<t t . � � Corp orati vnatu Signature; Signature: 1A4C7D8A4F6648A... '-CD261E4F15914F0 Print Name: Andrei Grama Print Name: Alexa Marsh Sunrun ID Number: 1873978073 Date: 9/11/2024 Title: Project Operations Contract Version 1.0 Proposal:PKVNK1VZCNRC-H Version 2021Q4V1 Proposal Id:a086Q00000ovAKB Agreement:a4m6Q000003Tza0QAC Template Order:320 Template Key:OT_213EAI437705 City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111 , S 150A. Address of the work: 735 Westhampton Rd, Northampton The debris will be transported by: Casella Waste Systems Casella Waste Systems The debris will be received by: 686 Main St, Holyoke, MA 01040 Building permit number: Name of Permit Applicant Robert Decker IV 10/2/2024 ea,49 7 ti Date Signature of Permit Applicant