Loading...
Plans_Berube, Stephen_REV A1_StampedCOVER SHEET SCOPE OF WORK GENERAL NOTES REV NAME DATE COMMENTS PAGE REV: A1 9/23/2024 150 PADGETTE ST UNIT A, CHICOPEE, MA, 01022-1333 PHONE 0 FAX 0 STEPHEN BERUBE 450 ROCKY HILL RD, NORTHAMPTON, MA, 01062 PROJECT NUMBER: 224R-450BERU SHEET DESIGNER: FLORIEN NIYONKURU CUSTOMER RESIDENCE: TEL. (413) 324-3465 APN: NHAM-000044-000094-000001 #180120 (415) 580-6920 ex3 PV-1.0 VICINITY MAP • SYSTEM SIZE: 3690W DC, 3800W AC • MODULES: (9) HANWHA Q-CELLS: Q.PEAK DUO BLK ML-G10+ 410 • INVERTERS: (1) GROWATT NEW ENERGY TECHNOLOGY CO LTD: MIN 3800TL-XH-US • RACKING: TOPSPEED, ATTACHMENT DETAIL, MOUNT TO WOOD DECK: SNR-DC-30004 • ALL WORK SHALL GENERALLY CONFORM WITH MA 9TH ED. CMR 780 (2015 IBC/IEBC), 2023 NEC AND 2023 MA ELECTRICAL CODE 527 CMR 12.00 (2023 NFPA 70 WITH MA AMENDMENTS), MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 11.2 AMPS MODULE SHORT CIRCUIT CURRENT. • 17.5 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (A) & 690.8 (B)]. • PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM EXT EXTERIOR INT INTERIOR MSP MAIN SERVICE PANEL (N)NEW NTS NOT TO SCALE OC ON CENTER PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS TYP TYPICAL V VOLTS W WATTS LAN LANDSCAPE POR PORTRAIT SOLAR MODULES TOPSPEED MOUNT LEGEND SCALE: NTS MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) PV LOAD CENTER SUB-PANEL CB ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS SUNRUN METER METAL PIPE VENT DEDICATED PV METER SERVICE ENTRANCE IQ COMBINER BOX HARDSCAPE PROPERTY LINE INTERIOR EQUIPMENT SHOWN AS DASHED PL SE MP SP LC SM PM INV AC DC Template_version_4.0.95 SHEET INDEX • RAPID SHUTDOWN: (9) TIGO ENERGY, INC TS4-A-F ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE PAGE #DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-4.0 ELECTRICAL PV-5.0 SIGNAGE • ADD 200AMP MAIN BREAKER KIT PLPLPLPLPLPLPL PL PL PLPLPLPLPLPLPLPL PL PL PL PAGE REV: A1 9/23/2024 150 PADGETTE ST UNIT A, CHICOPEE, MA, 01022-1333 PHONE 0 FAX 0 STEPHEN BERUBE 450 ROCKY HILL RD, NORTHAMPTON, MA, 01062 PROJECT NUMBER: 224R-450BERU SHEET DESIGNER: FLORIEN NIYONKURU CUSTOMER RESIDENCE: TEL. (413) 324-3465 APN: NHAM-000044-000094-000001 #180120 (415) 580-6920 ex3 SITE PLAN #SSTAMPSP #ESTAMPSP SITE PLAN - SCALE = 3/32" = 1'-0" Template_version_4.0.95 PV-2.0 NOTES: ·RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS: ·TOTAL ROOF SURFACE AREA: 1835 SQFT. ·TOTAL PV ARRAY AREA: 190.2 SQ FT. ·PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA) * 100 = 10.4% (E) RESIDENCE (N) ARRAY AR-01 FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) SE MP ACINV ROCKY HIL L R D (E) DRIVEWAY (E) DECK ARRAY PITCH TRUE AZIM PV AREA (SQFT) AR-01 28°170°253.6 ROOF PATHWAYS (3' TYP) (E) DETACHED STRUCTURE NOTE: ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE INSTALLED ON EACH MODULE PER NEC 690.12 PAGE REV: A1 9/23/2024 150 PADGETTE ST UNIT A, CHICOPEE, MA, 01022-1333 PHONE 0 FAX 0 STEPHEN BERUBE 450 ROCKY HILL RD, NORTHAMPTON, MA, 01062 PROJECT NUMBER: 224R-450BERU SHEET DESIGNER: FLORIEN NIYONKURU CUSTOMER RESIDENCE: TEL. (413) 324-3465 APN: NHAM-000044-000094-000001 #180120 (415) 580-6920 ex3 D1 - AR-01 - SCALE: 3/16" = 1'-0" AZIM:170° PITCH: 28° PV-3.0 LAYOUT #SSTAMP Template_version_4.0.95 DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 40 PSF WIND SPEED: 117 MPH 3-SEC GUST. S.S. LAG SCREW (4) #14 X 2.25" SS SEALING WASHER WOOD SCREWS FULLY PENETRATING THROUGH WOOD DECK STRUCTURAL NOTES ·EXISTING STRUCTURE IS ASSUMED TO BE A LIGHT-FRAME WOOD ROOF AND FREE FROM DAMAGE, DETERIORATION, OR MODIFICATION THAT WOULD COMPROMISE ITS ORIGINAL DESIGN INTEGRITY. CONTACT ENGINEER OF RECORD IF FOLLOWING MINIMUM REQUIREMENTS ARE NOT SATISFIED IN COMPLIANCE WITH THE STATED RACKING DESIGN: ··2X WOOD FRAMING (NOMINAL) ··FRAMING SPACING AT 24" O.C. MAX ··3/8"MIN SHEATHING (OSB/PLY) ·INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. ·MOUNT NUMBER FOR LEADING DOWNSLOPE EDGE SHALL MATCH REQUIREMENTS LISTED ABOVE ·IF A MODULE (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGE (EXCEPT VALLEYS), ADDITIONAL MOUNTS WILL BE REQUIRED IN THE FOLLOWING CONFIGURATIONS: ··EAVE & RIDGE - 3 TOPSPEED ATTACHMENTS MUST BE USED ON THE MODULE EDGE. ··GABLE & HIP - 3RD TOPSPEED ATTACHMENT MUST BE ADDED ON THE MODULE CORNER NEAREST TO THE ROOF EDGE. ROOF INFO ATTACHMENT INFORMATION Name Type Height Detail Minimum Number of Mounts per Up-Slope Edge (Landscape/Portrait) Max Landscape Overhang Max Portrait Overhang AR-01 COMP SHINGLE - TOPSPEED 2-Story TOPSPEED, ATTACHMENT DETAIL, MOUNT TO WOOD DECK: SNR-DC-30004 2 / 2 1'-6"0'-10" 18'-8" 10'-5" 41'-4"1'-4" 1'-7" 1'-3" 4'-3"PRREOEFE NIS GSNIOE N LA OF M H ATLSASEA CWHNUOSMETMTOSCVINCENT MWUMVANEZA CIVIL NO. 54772 STRUCTURAL ONLY Signed 9/23/2024 NEW 200A MAIN BREAKER END FED EXISTING 225A MAIN PANEL 225A BUS M GROWATT MIN 3800TL-XH-US 3800 WATT INVERTER 3 LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT 1 2 J-BOX ·POINT OF INTERCONNECTION:705.12(B)(2), LOAD SITE TAP ·METER NUMBER: 05088032 ·EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS ·NOTE: TOTAL PV BACKFEED = 20A USED FOR INTERCONNECTION CALCULATIONS EXISTING MAIN 200 A SERVICE BRAKER 3 (N) LOCKABLE BLADE TYPE FUSED AC DISCONNECT SQUARE D D 222NRB, 120/240VAC 20A FUSES HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 410 STRING 1 OF 9 MODULES 9 TIGO TS4-A-F MODULE LEVEL RAPID SHUTDOWN DEVICES CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (2) 10 AWG (PV WIRE)N/A 10 AWG (BARE)Open Air 2 Inverter Input (4) 8 AWG THHN/THWN-2 N/A 10 AWG THHN/THWN-2 3/4 EMT 3 Inverter Output (2) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT PAGE REV: A1 9/23/2024 150 PADGETTE ST UNIT A, CHICOPEE, MA, 01022-1333 PHONE 0 FAX 0 STEPHEN BERUBE 450 ROCKY HILL RD, NORTHAMPTON, MA, 01062 PROJECT NUMBER: 224R-450BERU SHEET DESIGNER: FLORIEN NIYONKURU CUSTOMER RESIDENCE: TEL. (413) 324-3465 APN: NHAM-000044-000094-000001 #180120 (415) 580-6920 ex3 PV-4.0 ELECTRICAL #ESTAMP SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: SYSTEM OPEN CIRCUIT VOLTAGE: MAX ALLOWABLE DC VOLTAGE: SYSTEM SHORT CIRCUIT CURRENT: 3690 W 458 V 600 V 28 A MODULE CHARACTERISTICS HANWHA Q-CELLS: Q.PEAK DUO BLK ML-G10+ 410: OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 410 W 45.37 V 37.64 V 11.2 A Template_version_4.0.95 ·INSTALLER MUST CHECK THE CONDITION, INSTALLABILITY AND CODE COMPLIANCE OF EXISTING EQUIPMENT. PAGE REV: A1 9/23/2024 150 PADGETTE ST UNIT A, CHICOPEE, MA, 01022-1333 PHONE 0 FAX 0 STEPHEN BERUBE 450 ROCKY HILL RD, NORTHAMPTON, MA, 01062 PROJECT NUMBER: 224R-450BERU SHEET DESIGNER: FLORIEN NIYONKURU CUSTOMER RESIDENCE: TEL. (413) 324-3465 APN: NHAM-000044-000094-000001 #180120 (415) 580-6920 ex3 SIGNAGE PV-5.0 #ESTAMP NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. CAUTION: 450 ROCKY HILL RD, NORTHAMPTON, MA, 01062 MULTIPLE SOURCES OF POWERWARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2023: 705.12(B)(2) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. 4" 3" LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2023: 690.12(D) ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2023: 690.13(B), 705.20(7), 706.15(C) PER CODE(S): NEC 2023 : 705.10(2) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH PER CODE(S): NEC 2023: 690.12(D)(2), IFC 2018: 1204.5.3 INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC600 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2023: 690.7(D) WARNING: PHOTOVOLTAIC POWER SOURCE WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2023: 690.31(D)(2) WARNING! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2023: 705.30(C) LABEL LOCATION: MAIN SERVICE DISCONNECT For customer questions or service issues, call our Customer Care team at: 1.833.607.6937 ext. 0 *Prior authorization from Sunrun is required for any maintenance/service activity.HIC 180120 Emergency responders, for 24 hour emergency service call: 1.855.478.6786 911 For customers in case of emergency, call: This solar PV system is owned and operated by: Template_version_4.0.95 SOLAR PANELS ON ROOF INVERTER (EXT) SERVICE ENTRANCE AC DISCONNECT MAIN PANEL RAIL STANDOFFS & FOOTINGS SOLAR MODULES