Loading...
Leblanc Solar Permit AppThe Commonwealth of Massachusetts Board of Building Regulations and Standards Massachusetts State Building Code, 780 CMR Building Permit Application To Construct, Repair, Renovate Or Demolish a One- or Two-Family Dwelling FOR MUNICIPALITY USE Revised Mar 2011 This Section For Official Use Only Building Permit Number: _____________________ Date Applied: ______________________________ ___________________________________ ____________________________________________ ___________ Building Official (Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: ____________________________________________ 1.1a Is this an accepted street? yes_____ no_____ 1.2 Assessors Map & Parcel Numbers _____________________ ____________________ Map Number Parcel Number 1.3 Zoning Information: _______________ ___________________ Zoning District Proposed Use 1.4 Property Dimensions: _____________________ ____________________ Lot Area (sq ft) Frontage (ft) 1.5 Building Setbacks (ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c. 40, § 54) Public † Private † 1.7 Flood Zone Information: Zone: ___ Outside Flood Zone? Check if yes† 1.8 Sewage Disposal System: Municipal †On site disposal system † SECTION 2: PROPERTY OWNERSHIP1 2.1 Owner 1 of Record: ________________________________________ _________________________________________________ Name (Print) City, State, ZIP _____________________________________________ _________________ ___________________________________ No. and Street Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK2 (check all that apply) New Construction †Existing Building †Owner-Occupied †Repairs(s) †Alteration(s) †Addition † Demolition †Accessory Bldg. †Number of Units_____ Other †Specify:________________________ Brief Description of Proposed Work2:_________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: (Labor and Materials)Official Use Only 1. Building $1. Building Permit Fee: $_______ Indicate how fee is determined: †Standard City/Town Application Fee †Total Project Cost3 (Item 6) x multiplier _______ x _______ 2. Other Fees: $_________ List:_________________________________________________ ____________________________________________________ Total All Fees: $_______________ Check No. ______Check Amount: _______Cash Amount:______ †Paid in Full †Outstanding Balance Due:__________ 2. Electrical $ 3. Plumbing $ 4. Mechanical (HVAC) $ 5. Mechanical (Fire Suppression) $ 6. Total Project Cost:$ SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License (CSL) ________________________________________________________ Name of CSL Holder _________________________________________________________ No. and Street _________________________________________________________ City/Town, State, ZIP _________________________________________________________ __________________ ______________________________________ Telephone Email address _____________________ ______________ License Number Expiration Date List CSL Type (see below) _______________ Type Description U Unrestricted (Buildings up to 35,000 cu. ft.) R Restricted 1&2 Family Dwelling M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances I Insulation D Demolition 5.2 Registered Home Improvement Contractor (HIC) ______________________________________________________________ HIC Company Name or HIC Registrant Name ______________________________________________________________ No. and Street ________________________________________ ____________________ City/Town, State, ZIP Telephone _____________________ ______________ HIC Registration Number Expiration Date _______________________________________ Email address SECTION 6: WORKERS’ COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152. § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ……….  No ………..  SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER’S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, as Owner of the subject property, hereby authorize_____________________________________________________ to act on my behalf, in all matters relative to work authorized by this building permit application. ______________________________________________________ ______________________ Print Owner’s Name (Electronic Signature) Date SECTION 7b: OWNER1 OR AUTHORIZED AGENT DECLARATION By entering my name below, I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. _____________________________________________________________ ______________________ Print Owner’s or Authorized Agent’s Name (Electronic Signature) Date NOTES: 1.An Owner who obtains a building permit to do his/her own work, or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor (HIC) Program), will not have access to the arbitration program or guaranty fund under M.G.L. c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2.When substantial work is planned, provide the information below: Total floor area (sq. ft.) _________________________ (including garage, finished basement/attics, decks or porch) Gross living area (sq. ft.) __________________ Habitable room count ______________________ Number of fireplaces______________________ Number of bedrooms _____________________ Number of bathrooms ____________________ Number of half/baths ______________________ Type of heating system ___________________ Number of decks/ porches __________________ Type of cooling system_____________________ Enclosed ______________Open _____________ 3.“Total Project Square Footage” may be substituted for “Total Project Cost” Phil SmithSean G O'BrikisMichael S Blanchard 6 Torrey St1434 14th Ave142 Nelson Street Dorothy, NJ 08317West Springfield, MA 01089 413-203-9088 applications.westma@trinity-solar.com CS CS-116655CS-088684 9/10/2025 UU Trinity Solar Inc DBA Trinity Solar 20 Patterson Brook Road - Unit 10 West Wareham MA 02576 413-203-9088 170355 10/11/20210/11/2023 applications.westma@trinity-solar.com Please See Attached X X X x x City of Northampton Massachusetts DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street ● Municipal Building Northampton, MA 01060 CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40, S54, a condition of Building Permit Number ________________ is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A. The debris will be disposed of in: Location of Facility: ___________________________________________________ The debris will be transported by: Name of Hauler: ______________________________________________________ Signature of Applicant: __________________________________Date: ___________ NJ, Electrical Contractor business permit number 34EB00839200 NJ, HIC reg. # 13VH12957000 For other jurisdictions, please visit: http://www.trinity-solar.com/about-us/locations-and-licenses HOMEOWNERS AUTHORIZATION FORM I, , (print name) am the owner of the property located at address: . (print address) I hereby authorize Trinity Solar LLC (“Trinity Solar”) and its employees, agents, and subcontractors, including without limitation, , to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System, Battery System, roofing or other Trinity Solar offerings located on my property, applying and obtaining permission and approval for interconnection with the electric utility company, and registration with any state and/or local incentive program(s). This authorization includes the transfer/re-administering, and/or cancellation of any existing permits on file for the purpose of updating/applying with an alternate subcontractor. Without limitation to the generality of the foregoing I specifically authorize Trinity Solar et al. to populate technical details, fill-in, edit, compile, attach drawings, plans, data sheets and other documentation to, date, submit, re-submit, revise, amend and modify application, submission and certification documents (“Approvals Paperwork”), including those for which signature pages are included herewith for my signature, in furtherance of the related transaction, and I am providing any signatures to Approvals Paperwork for purposes of the foregoing. Trinity Solar will provide copies of Approvals Paperwork when submitted. My authorizations memorialized herein shall remain in full force and effect until revoked. I acknowledge that these authorizations are not required to proceed with the transaction and are not a condition of the related agreement included herewith but are being given for my own convenience and benefit in order to expedite the approvals processes. Electric Utility Company: __________________________ Electric Utility Account No.: ________________________ Electric Meter No.: _______________________________ Name on Electric Utility Account: ___________________ Customer Signature Print Name Date Corporate Headquarters 1-877-SUN-SAVES 2211 Allenwood Road Ph: 732-780-3779 Wall, New Jersey 07719 Fax: 732-780-6671 www.trinity-solar.com FOR INFORMATION ABOUT CONTRACTORS AND THE CONTRACTORS’ REGISTRATION ACT, CONTACT THE NEW JERSEY DEPARTMENT OF LAW AND PUBLIC SAFETY, DIVISION OF CONSUMERS AFFAIRS AT 1-888-656-6225. Matthew Leblanc 160 AcreBrook Dr Florence MA Lon Goodman National Grid 1407438029 ROSALYN DEVINCENTIS Matthew Leblanc 83047322 WESTSHORE DESIGN ENGINEERS, P.C. 6279 JOHNSTON RD. ALBANY Ϳ NEW YORK Ϳ 12203 WestShore Design Engineers ۅ 6279 Johnston Rd. ۅ Albany, NY 12203 Subject: Leblanc Residence 160 AcreBrook Dr. Florence, MA Dear Trinity Solar, The following references the Leblanc Residence in Florence, MA: 1. Existing roof framing: Pre-fabricated/engineered wood truss is 2x4 at 24”o.c. This existing structure is capable to support all the loads that are indicated below for this photovoltaic project. 2. Roof Loading: - 3psf dead load (modules plus mounting hardware) - 40psf ground snow load - 5psf roof materials - Exposure Category B, 117mph wind (3 sec.) This installation design will be in general conformance to the manufacturer’s specifications, and complies with all applicable laws, codes, and ordinances, specifically the International Building Code/IBC 2015 and International Residential Code/IRC 2015 including all MA regulations and amendments. The spacing and fastening of the mounting brackets is to have a maximum of 48”o.c. span between mounting brackets and secured using 5/16” diameter corrosive resistant steel lag bolts. To evenly distribute the load across the roof rafters, there shall be a minimum of 2 mounting brackets per rafter & min. 3” penetration of lag bolt per bracket, which is adequate to resist all 117mph wind live loads including wind shear. Ecofasten Smartfeet or industry similar for deck attachments installed per manufacturer recommendations and specifications. Thank you. Westshore Design Engineers 9/11/2024 John Eibert Nicolas Nitti, PE Project Coordinator President To: Trinity Solar 4 Open Square Way #410 Holyoke, MA 01040 Date: September 11, 2024 Ref.: 24090504 GENERAL NOTES1.All electrical materials shall be new and listed by recognizedelectrical testing laboratory Custom made equipment shall have complete test data submittedby the manufacturer attesting to its safety2.Outdoor equipment shall be NEMA 3R rated or equivalent3.All metallic equipment shall be grounded4.Contractor shall obtain electrical permits prior to installation andshall coordinate all inspections, testing commissioning andacceptance with the client, utility co. and city inspectors as needed.5.The electrical contractor shall verify the exact locations of servicepoints and service sizes with the serving utility company andcomply with all utility companies requirements.6.Drawings are diagrammatic only, routing of raceways shall beoption of the contractor unless otherwise noted and shall becoordinated with other trades.7.If the roof material or the roof structure not adequate for PVinstallation, call the engineer of record prior to installation. Thecontractor is responsible to verify that the roof is capable ofwithstanding the extra weight.8.If the distances for cable runs are different than shown, thecontractor shall notify the electrical engineer to validate the wiresize. Final drawings will be red-lined and updated as appropriate.9.Whenever a discrepancy in quality of equipment arises on thedrawing or specifications, the contractor shall be responsible forproviding and installing all materials and services required by thestrictest conditions noted on the drawings or in the specificationsto ensure complete compliance and longevity of the operablesystem required by the engineer of record.PHOTOVOLTAIC NOTES:1.Rooftop mounted photovoltaic panels and modules shall be tested,listed and identified by recognized testing laboratory2.Solar system shall not cover any plumbing or mechanical vents3.Modules and support structures shall be grounded unless racking has integrated ground.4.Removal of an interactive inverter or other equipment shall notdisconnect the bonding connection between the groundingelectrode conductor and the photovoltaic source and/or outputcircuit grounded conductors.5.All PV modules and associated equipment and wiring shall beprotected from physical damage.6.Live parts of PV source circuits and PV output circuits over 150v toground shall not be accessible to other than qualified persons while energized.7.Inverter is equipped with integrated DC disconnect, thus providingground fault protection8.All conductors shall be copper and 75 deg rated9.A single conductor shall be permitted to be used to perform themultiple functions of dc grounding, AC grounding and bondingbetween AC and DC systems.10.Non-current carrying metal parts of equipment shall be effectivelybonded together. Bond both ends of raceways.COVER PAGECP 0.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938NEWECOFASTENSITE MAP & PV LAYOUTELECTRICAL 1-LINE DIAGRAMSYSTEM LABELING DETAILPOWER OPTIMIZER DATA SHEETINVERTER DATA SHEETSHEET INDEXMODULE DATA SHEETRACKING DATA SHEETATTACHMENT DATA SHEETPV 1.0SYSTEM RATINGEQUIPMENT SUMMARYELECTRICAL INFORMATIONMAIN SERVICE PANEL BUS SIZE:MAIN SERVICE BREAKER SIZE:MOUNTING SYSTEM:BUILDING INFORMATIONCONSTRUCTION TYPE: V-BOCCUPANCY: R3ROOF:VICINITY MAP (SCALE: NTS)SATELLITE VIEW (SCALE: NTS)200A200A HANWHA 410 WATT MODULES WITHS500B POWER OPTIMIZERS, SOLAREDGEHD WAVE 6.0 KW INVERTERGOVERNING CODESDC 5.740 KW STCAC 6.000 KW STC14PV 2.0PV 3.0PV 4.0D 5.0D 6.0D 7.0D 8.0COVER PAGECP 0.0ASPHALT SHINGLEAC DISCONNECT DATA SHEETD 9.0PROPERTY PLANThese drawings are protected by copyright under US law. Any form ofreproduction is strictly prohibited without prior written approval fromEngineerinc.D 10.0THE INSTALLATION OF SOLAR ARRAYS ANDPHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITHTHE FOLLOWING CODES:·2023 National Electrical Code·2021 NFPA 1 - 527 CMR 1.00·2018 International Energy Conservation Code·2015 International Residential Code·2015 International Building Code·2015 International Mechanical CodeAS ADOPTED BY THE STATE OF MASSACHUSETTSALL OTHER ORDINANCE ADOPTED BY THELOCAL GOVERNING AGENCIES SITE MAP & PVLAYOUTPV 1.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938.................................................................................................MSP(N) Main Service PanelINDEXAC............(N) 60A AC Disconnect(N) Optimizer(E) Main MeterMM.....................................SOLAR MODULES___ Hanwha 410 WattModel #Q.PEAK DUO BLK ML-G10+INVERTERINVERTER TYPE: Central:Solar Edge Single Phase HD Wave6.0 kW InverterModel #SE6000H-USSNBBL14(240V)JB(N) Junction Box(N) Solar ModuleConduitFire Setback Line14TOTAL ROOF AREA: 1198TOTAL MODULE AREA: 30825.7% OF COVERAGEIN................................(N) InverterNOTE: PV ARRAY(S) SHALL NOT EXCEED EXISTING BUILDING HEIGHTNOTE: PV DISCONNECT TO BE LOCATED WITHIN 10 FEET OF UTILITY METERUtility Company: National GridUtility Account #: 1407438029Utility Meter #: 83047322200AECOFASTEN CLAMP(REFER TO SPEC SHEET FOR DETAILS)ECOFASTEN ''L'' FOOT6''SOLAR MODULE(REFER TO SPEC SHEET FOR DETAILS)ECOFASTEN RAILSOLAR MODULE(REFER TO SPEC SHEET FOR DETAILS)(REFER TO SPEC SHEET FOR DETAILS)ECOFASTEN FLASHINGEXISTING ASPHALT SHINGLES(REFER TO ENGINEERS LETTER FOR SPECS)(REFER TO ENGINEERS LETTER FOR SPECS)(REFER TO ENGINEERS LETTER FOR SPECS)EXISTING RAFTERSCALE: NOT TO SCALEPV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOFS.S.LAG BOLTAPOC SELANTMAXSCALE: NOT TO SCALEATTACHMENT & CLIP DETAILNOTES: * REFER TO MODULE SPECS FOR MODULE DIMENSIONS * DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPENEW PV SOLAR MODULE, TYPICAL(REFER TO EQUIPMENT SCHEDULEFOR SPECS AND QUANTITIES)NEW MID CLIP. TYPICAL(REFER TO ECOFASTEN SPECIFICATION/DATASHEET FOR DETAILS)NEW END CLIP. TYPICAL(REFER TO ECOFASTEN SPECIFICATION/DATASHEET FOR DETAILS)NEW ECOFASTEN RAIL TYPICALTO BE MOUNTED PERPINDICULAR TOSTRUCTURE (REFER TO ECOFASTENSPECIFICATION / DATA SHEET FORDETAILS)NEW MOUNTING FOOT / ATTACHMENTPOINTS, TYPICAL ( REFER TOENGINEERING LETTER FOR SPACINGAND DETALIS)NOTE: PV DISCONNECT 24/7 ACCESSIBLE AND LOCKABLERoof R114 - Hanwha 410W Modules14 - S500B OptimizersPitch: 24 DegOrientation: 159 DegACINMMMSPFront of building Back o f bu i ld ing Acrebrook DrJB18' ' f ire se tback18' ' f ire se tback3' fire pathway3' fire pathway<10'aaaaaaabbbbbbbSCALE:3/32" = 1'-0" 180° 90° 270°0°SWNE PROPERTY PLANPV 2.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938......................MSP Main Service PanelINDEXAC.........................AC DisconnectMain MeterMM...............................Solar ModuleIN.......................................Inverter.................Utility Company: National GridUtility Account #: 1407438029Utility Meter #: 83047322ACINMMMSPFront o f bu i ld ing Back o f bu i ld ing Acrebrook DrPROPERTY LINE86'-7"87'-10"86'-7"86'-10"24'-7"19'-8"30'-1"55'-2"SCALE:1/16" = 1'-0" 180° 90° 270°0°SWNE INVERTERSOLAR EDGE HD WAVE 6.0 kWMODEL #SE6000H-USSNBBL14(240V)Solar Edge single phaseHD Wave 6.0 kWInverter have IntegratedDC Disconnect safety switchand Arc Fault ProtectionAtticWall DU222RBELECTRICAL ONELINE DIAGRAMPV 3.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-09381STRING: A J BOXNEMA3R27NEWNON CENTER _____MAIN C/BNOTE: Service Panel does not contain center fed Main Breaker:NEW______ MAINSERVICEPANEL120/240V,1P, 3WGEC(N) GROUNDINGELECTRODE SYSTEM200A200AHANWHA 410 WATT MODULESS500B POWER OPTIMIZERS1414(2) #10 AWG PV WIRE,(1) #6 AWG EGCFREE IN THE AIR(4) #10 AWG THWN/THWN-2(1) #10 AWG GND3/4" Conduit, 15 FEET(2) #8AWG THWN/THWN-2(1) #10 AWG THWN/THWN-2(1) #10 AWG GND3/4" Conduit, 5 FEET(4) #10 AWG THWN/THWN-2(1) #10 AWG GND3/4" Conduit, 5 FEETNOTE: CONDUIT TYPE SHALL BE CHOSEN BY THEINSTALLATION CONTRACTOR TO MEET OR EXCEEDNEC AND LOCAL AHJD REQUIREMENTSUtility Company: National GridUtility Account #: 1407438029Utility Meter #: 83047322127SolarEdge Power Optimizer S500BRated DC Input Power - 500 WattsMaximum Input Voltage - 125 VdcMPPT Range - 12.5 to 105 VdcMaximum Input Current - 15 AdcMaximum Output Current - 15 AdcString Limitations - 6 to 25 Optimizers,5700 watts STC per string maximum.Solaredge optimizers have integratedrapid shut down60A NON-FUSED AC DISCONNECT,LOCKABLE,BLADE TYPE,NEMA3R 120 / 240V(UTILITY REQUIRED)INSTALL 40A 2P CB(PV)INSTALL AT OPPOSITEEND OF BUS FROMMAIN FEEDER CBPV ARRAY RATINGWIRE SIZE CALCULATIONPV ARRAYFROM JUNCTION BOX TO INVERTERNumber Modules14Q.PEAK DUO BLK ML-G10+ 410Hanwha 410 WattMaximum Current (A)7 * 410 / 380 = 7.55Number Inverters1Solar Edge 6kW InverterSE6000H-USSNBBL14(240V)Considers Continuous (A)7.55 * 1.25 = 9.44Total DC Wattage (Watts)Watts STC, (Watts/Module) 14 * 410 = 5740Short Circuit Current (A)9.44 * 1.25 = 11.8Array CurrentsI-SC11.2AI-MP10.89ARaceway Height From Roof (Temp 39+22=61C)3 1/2"Module VoltageV-OC45.37VV-MP37.64VTemp. Derate Factor (A)11.8 / 0.71 = 16.62SYSTEM POWER#of wire(#of Strings*2)4Number Of Strings2Max Number of Modules Per String7More Than 3 CCC Adjust. Factor0.8Max DC Wattage In Strings7 * 410 = 2870 < 5700 (Watts)Max AC Voltage 120/240VAdjusted Conductor Ampacity(A)16.62 / 0.8 = 20.77FROM INVERTER TO MAIN PANELWire Size from NEC Table 310.15(b)1610 AWGTotal Current (A)25Ambient Temp Factor Per NEC Table 310.15(b)(2)(a)0.71Total AC Wattage (Watts)6000Consider Continuous (A)25 * 1.25 = 31.25Temperature Adjustment31.25 / 0.91 = 34.34Conductor Size From NEC Table 310.168 AWGMAIN PANELPV Backfeed Breaker Size (A)40Main Breaker (A)200Main Bus Rating (A)200Total Amps On Bus (120%)40 + 200 = 240 <= 240 (A)<10'(E)MAIN METERNATIONAL GRID NOTES:ANY NEW METERING AND DISCONNECT EQUIPMENT SHALL BE GROUPED, LOCATED OUTSIDE, AND 24/7 LOCKABLE ANDACCESSIBLE, IN ACCORDANCE WITH ESB 7.1.1. ALL EQUIPMENT LOCATIONS SHALL BE APPROVED BY NATIONAL GRIDMETERING DEPARTMENT PRIOR TO INSTALLATION.ALL CONSTRUCTION SHALL COMPLY WITH ESB 750 & ESB 756. INSTALLATIONS CANNOT INCLUDE ANY KIND OF TAPS,METER COLLARS OR ADAPTERS INSIDE NATIONAL GRID OWNED AND MAINTAINED EQUIPMENT, METER SOCKETS,METER CABINETS OR ANYWHERE THERE ARE UN-METERED CONDUCTORS(2) #8AWG THWN/THWN-2(1) #10 AWG THWN/THWN-2(1) #10 AWG GND3/4" Conduit, 5 FEETSTRING: B SYSTEM LABELINGDETAILSPV 4.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938(STICKER TO BE LOCATED ONCONDUIT WITH DC CURRENTEVERY 4' HORIZONTALLY OR10' VERTICALLY AND 1' FROMEACH SIDE OF A BEND)(TO BE LOCATED ONSUB-PANEL ONLYWHEN SUB-PANEL ISDEDICATED FOR PV ONLY)(STICKER LOCATEDINSIDE PANELNEXT TO SOLAR BREAKER)(STICKER LOCATEDINSIDE PANELBELOW PV BREAKER)PV ARRAYJ BOXINVERTERINTEGRATEDDC DISCONNECTPV SUB-PANEL* if applicableSUB-PANEL* if applicableACDISCONNECT* if applicableMETERMAIN SERVICEPANEL*if applicable(STICKER LOCATEDON THE PV SUB PANEL)CAUTIONAUTHORIZED SOLARPERSONNAL ONLY!CAUTIONSOLAR DC CURRENT PRESENTDURING DAYLIGHT HOURSWARNING!ELECTRIC SHOCK HAZARD.IF GROUND FAULT IS INDICATED,NORMALLY GROUNDEDCONDUCTORS MAY BE UNGROUNDED AND ENERGIZED.DC DISCONNECTDC PHOTOVOLTAIC POWER SOURCERATED MAX POWER POINT CURRENT- AMPSRATED MAX POWER POINT VOLTAGE- VOLTSMAXIMUM SYSTEM VOLTAGE- VOLTSSHORT CIRCUIT CURRENT- AMPSWARNING!ELECTRIC SHOCK HAZARD.DO NOT TOUCH THE TERMINALS.TERMINALS ON BOTH THE LINE ANDLOAD SIDES MAY BE ENERGIZED INTHE OPEN POSITION.PV LOAD CENTER SIZED FOR PVBREAKERS ONLY OR RENDERED UNABLETO ACCEPT ANY ADDITIONAL LOADS.PV SUB-PANEL ONLYAC DISCONNECTAC PHOTOVOLTAIC POWER SOURCERATED AC OUTPUT CURRENT: A MAXNOMINAL AC OPERATING VOLTAGE: 240 VacTHIS PANEL FED BYMULTIPLE SOURCES(UTILITY & SOLAR)SOLARWARNING!INVERTER OUTPUT CONNECTION. DO NOTRELOCATE THIS OVERCURRENT DEVICEPermanent directory or plaque providing location of service disconnecting means and photovoltaic systemdisconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved ormachine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanentlyattached to the equipmenq or in the required location using an approved method that is suitable to withstand theenvironment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesionrequirements of Underwriters Laboratories marking and labeling system 969(UL969).31.25LABEL 1LABEL 2LABEL 3LABEL 4LABEL 5LABEL 6LABEL 7LABEL 8LABEL 9LABEL 10LABEL 11LABEL 1287109127798107798101174512DIRECTORYMARKINGS, LABELS AND WIRING SIGNSA. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system.This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removalB. Main Service Disconnect.1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed outside cover if the main service disconnect is operable with the service panel closed.2. Commercial buildings - Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated3. Markings: Verbiage, Format and Type of Material. a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED b. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable adhesive materials meet thisrequirement.C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: 1. Markings: Verbiage, Format and Type of Material. a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies,at turns, above and for below penetrations, all DC combiners and junction boxes b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to "V. V-3b, c" of this requirement. c. Inverters are not required to have caution markings1.Marking is required on all interior and exterior DC conduit raceways,enclosures,cable assemblies,and junction boxes,combiner boxes and disconnects.2.The materials used for marking shall be reflective,weather resistant material suitable for the environment.Minimum 3/8 "letter height; all upper case letters Arial or similar font; Red background with white lettering.3.Marcking shall contain the words: WARNING : PHOTOVOLTAIC POWER SOURCE.4.Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operatedSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR ELECTRICPV PANELS10.8938048011.8 Commonwealth of Massachusetts Division of Occupational Licensure Board of Building Regulations and Standards Construction Supervisor CS-088684 Expires: 07/06/2026 MICHAEL S BLANCHARD 142 NELSON STREET WEST SPRINGFIELD MA 01089 Commissioner Construction Supervisor Unrestricted - Buildings of any use group which contain less than 35,000 cubic feet (991 cubic meters) of enclosed space. Failure to possess a current edition of the Massachusetts State Building Code is cause for revocation of this license. Contact OPSI: (617) 727-3200 or visit www.mass.gov/dpl/opsi SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. INSURER(S) AFFORDING COVERAGE INSURER F : INSURER E : INSURER D : INSURER C : INSURER B : INSURER A : NAIC # NAME:CONTACT (A/C, No):FAX E-MAILADDRESS: PRODUCER (A/C, No, Ext):PHONE INSURED REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. OTHER: (Per accident) (Ea accident) $ $ N / A SUBR WVD ADDL INSD THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. $ $ $ $PROPERTY DAMAGE BODILY INJURY (Per accident) BODILY INJURY (Per person) COMBINED SINGLE LIMIT AUTOS ONLY AUTOSAUTOS ONLY NON-OWNED SCHEDULEDOWNED ANY AUTO AUTOMOBILE LIABILITY Y / N WORKERS COMPENSATION AND EMPLOYERS' LIABILITY OFFICER/MEMBER EXCLUDED? (Mandatory in NH) DESCRIPTION OF OPERATIONS below If yes, describe under ANY PROPRIETOR/PARTNER/EXECUTIVE $ $ $ E.L. DISEASE - POLICY LIMIT E.L. DISEASE - EA EMPLOYEE E.L. EACH ACCIDENT EROTH-STATUTEPER LIMITS(MM/DD/YYYY)POLICY EXP(MM/DD/YYYY)POLICY EFFPOLICY NUMBERTYPE OF INSURANCELTRINSR DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) EXCESS LIAB UMBRELLA LIAB $EACH OCCURRENCE $AGGREGATE $ OCCUR CLAIMS-MADE DED RETENTION $ $PRODUCTS - COMP/OP AGG $GENERAL AGGREGATE $PERSONAL & ADV INJURY $MED EXP (Any one person) $EACH OCCURRENCE DAMAGE TO RENTED $PREMISES (Ea occurrence) COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: POLICY PRO-JECT LOC CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) CANCELLATION AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) © 1988-2015 ACORD CORPORATION. All rights reserved. CERTIFICATE HOLDER The ACORD name and logo are registered marks of ACORD HIRED AUTOS ONLY 5/29/2024 Arthur J.Gallagher Risk Management Services,LLC 300 Fellowship Road Suite 200 Mount Laurel NJ 08054 Alexander Gillikin 856-482-9900 856-482-1888 CherryHill.BSD.CertM@AJG.com Gotham Insurance Company 25569 TRINHEA-03 National Union Fire Insurance Company of Pittsburg 19445TrinitySolar,LLC 4 Open Square Way,Suite 410 Holyoke,MA 01040 Endurance American Specialty Ins Co 41718 Liberty Insurance Underwriters Inc 19917 Columbia Casualty Company 31127 1145849548 A X 2,000,000 X 100,000 5,000 1,000,000 2,000,000 X GL202100013378 6/1/2023 6/1/2025 2,000,000 B 2,000,000 X CA 2960145 6/1/2024 6/1/2025 A C D E X 5,000,000 X EX202300001871 ELD30006989102 1000231834-08 7039650582 6/1/2023 6/1/2024 6/1/2024 6/1/2024 6/1/2025 6/1/2025 6/1/2025 6/1/2025 5,000,000 Limit x of $5,000,000 19,000,000 B X N WC 013588107 6/1/2024 6/1/2025 1,000,000 1,000,000 1,000,000 B Automobile Comp/Collusion Ded.CA 2960145 6/1/2024 6/1/2025 All Other Units Truck-Tractors and Semi-Trailers $250/$500 $250/$500 Evidence of insurance. Evidence of Insurance INVERTERDATA SHEETD 5.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938 POWER OPTIMIZERDATA SHEETD 6.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938 MODULEDATA SHEETD 7.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938 RACKINGDATA SHEETD 8.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938 ATTACHMENTDATA SHEETD 9.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938 AC DISCONNECTDATA SHEETD 10.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938 APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC), 527 CMR 12.00 City or Town of: __________________________________ Date: ___________________ To the Inspector of Wires: By this application, the undersigned gives notices of his or her intention to perform the electrical work described below. Location (Street & Number): ____________________________________________ Unit No.: ________________________ Owner or Tenant: __________________________________________ Email: ____________________________________ Owner’s Address: ____________________________________________________ Phone No.: ______________________ Is this permit in conjunction with a building permit? (Check appropriate box) Yes No Permit No.:_________________ Purpose of Building: _____________________________________ Utility Authorization No.: ___________________ Existing Service: _____________ Amps _____/_____ Volts Overhead Underground No. of Meters: _____ New Service: _____________ Amps _____/_____ Volts Overhead Underground No. of Meters: _____ Description of Proposed Electrical Installation: _____________________________________________________________ ______________________________________________________________________________________________________ Completion of the following table may be waived by the Inspector of Wires. No. of Receptable Outlets: No. of Switches: Generator KW Rating: Type: No. Luminaires: No. of Recessed Luminaires: No. Wind Generators: Wind KW Rating: No. Appliances: KW: No. Water Heaters: KW: No. Transformers: Total KVA: Space Heating KW: Heating Equipment KW: No. Motors: Total HP: Total KW: No. Heat Pumps: Total KW: Total Tons: Fire Alarm System No. of Devices: Swimming Pool: In-Grnd. Above-Grnd. Hot-Tub No. of Self-Contained Detection/Alerting Devices: No. Oil Burners: No. Gas Burners: Video System No. of Devices: No. Air Conditioners: Total Tons: Telecom System No. of Outlets: No. Energy Storage Systems: KWH Storage Rating: Security System No. of Devices: Solar PV KW DC Rating: Solar PV KW AC Rating: No. of Modules: Roof-Mount Ground-Mount No. of Electric Vehicle Supply Equipment: Level 1 Level 2 Level 3 Rating: OTHER: Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: _________________________________ (When required by municipal policy) Date Work to Start: _________________ Inspections to be requested in accordance with MEC Rule 10, and upon completion. or C-1 Master/Systems Licensee: __________________________________________ LIC. No.: __________________________ Journeyman Licensee: _____________________________________________ LIC. No.: __________________________ Security System Business requires a Division of Occupational Licensure “S” LIC. S-LIC. No.: __________________________ Address: ______________________________________________________________________________________________ I certify, under the pains and penalties of perjury, that the information on this application is true and complete. Licensee: ____________________________Print Name: ________________________________Cell. No.: _______________ INSURANCE COVERAGE: Unless waived by the owner, no permit for the performance of electrical work may issue unless the licensee provides proof of liability including “completed operation” coverage or its substantial equivalent. The undersigned certifies that such coverage is in force and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE BOND OTHER Specify: _____________________________________ OWNER’S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the: (Check one) Owner Owner’s agent Owner / Agent: _______________________________________________ Tel. No.: ________________________________ Signature: ____________________________________________________ Email.: _________________________________ Commonwealth of Massachusetts Department of Fire Services BOARD OF FIRE PREVENTION REGULATIONS Official Use Only Permit No.: __________________________ Occupancy and Fee Checked: ____________ [Rev. 1/2023] Residential X TBD Brian K. Macpherson Brian K. Macpherson 21233 A Email: _________________________________________________________ Telephone No.: __41______3-203-9088________________ 508-577-3391Brian Macpherson X FIRM NAME: __________________________________________________ A-1 X LIC. No.: __________ 12525 B Install kW solar on roof. () panels GENERAL NOTES1.All electrical materials shall be new and listed by recognizedelectrical testing laboratory Custom made equipment shall have complete test data submittedby the manufacturer attesting to its safety2.Outdoor equipment shall be NEMA 3R rated or equivalent3.All metallic equipment shall be grounded4.Contractor shall obtain electrical permits prior to installation andshall coordinate all inspections, testing commissioning andacceptance with the client, utility co. and city inspectors as needed.5.The electrical contractor shall verify the exact locations of servicepoints and service sizes with the serving utility company andcomply with all utility companies requirements.6.Drawings are diagrammatic only, routing of raceways shall beoption of the contractor unless otherwise noted and shall becoordinated with other trades.7.If the roof material or the roof structure not adequate for PVinstallation, call the engineer of record prior to installation. Thecontractor is responsible to verify that the roof is capable ofwithstanding the extra weight.8.If the distances for cable runs are different than shown, thecontractor shall notify the electrical engineer to validate the wiresize. Final drawings will be red-lined and updated as appropriate.9.Whenever a discrepancy in quality of equipment arises on thedrawing or specifications, the contractor shall be responsible forproviding and installing all materials and services required by thestrictest conditions noted on the drawings or in the specificationsto ensure complete compliance and longevity of the operablesystem required by the engineer of record.PHOTOVOLTAIC NOTES:1.Rooftop mounted photovoltaic panels and modules shall be tested,listed and identified by recognized testing laboratory2.Solar system shall not cover any plumbing or mechanical vents3.Modules and support structures shall be grounded unless racking has integrated ground.4.Removal of an interactive inverter or other equipment shall notdisconnect the bonding connection between the groundingelectrode conductor and the photovoltaic source and/or outputcircuit grounded conductors.5.All PV modules and associated equipment and wiring shall beprotected from physical damage.6.Live parts of PV source circuits and PV output circuits over 150v toground shall not be accessible to other than qualified persons while energized.7.Inverter is equipped with integrated DC disconnect, thus providingground fault protection8.All conductors shall be copper and 75 deg rated9.A single conductor shall be permitted to be used to perform themultiple functions of dc grounding, AC grounding and bondingbetween AC and DC systems.10.Non-current carrying metal parts of equipment shall be effectivelybonded together. Bond both ends of raceways.COVER PAGECP 0.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938NEWECOFASTENSITE MAP & PV LAYOUTELECTRICAL 1-LINE DIAGRAMSYSTEM LABELING DETAILPOWER OPTIMIZER DATA SHEETINVERTER DATA SHEETSHEET INDEXMODULE DATA SHEETRACKING DATA SHEETATTACHMENT DATA SHEETPV 1.0SYSTEM RATINGEQUIPMENT SUMMARYELECTRICAL INFORMATIONMAIN SERVICE PANEL BUS SIZE:MAIN SERVICE BREAKER SIZE:MOUNTING SYSTEM:BUILDING INFORMATIONCONSTRUCTION TYPE: V-BOCCUPANCY: R3ROOF:VICINITY MAP (SCALE: NTS)SATELLITE VIEW (SCALE: NTS)200A200A HANWHA 410 WATT MODULES WITHS500B POWER OPTIMIZERS, SOLAREDGEHD WAVE 6.0 KW INVERTERGOVERNING CODESDC 5.740 KW STCAC 6.000 KW STC14PV 2.0PV 3.0PV 4.0D 5.0D 6.0D 7.0D 8.0COVER PAGECP 0.0ASPHALT SHINGLEAC DISCONNECT DATA SHEETD 9.0PROPERTY PLANThese drawings are protected by copyright under US law. Any form ofreproduction is strictly prohibited without prior written approval fromEngineerinc.D 10.0THE INSTALLATION OF SOLAR ARRAYS ANDPHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITHTHE FOLLOWING CODES:·2023 National Electrical Code·2021 NFPA 1 - 527 CMR 1.00·2018 International Energy Conservation Code·2015 International Residential Code·2015 International Building Code·2015 International Mechanical CodeAS ADOPTED BY THE STATE OF MASSACHUSETTSALL OTHER ORDINANCE ADOPTED BY THELOCAL GOVERNING AGENCIES SITE MAP & PVLAYOUTPV 1.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938.................................................................................................MSP(N) Main Service PanelINDEXAC............(N) 60A AC Disconnect(N) Optimizer(E) Main MeterMM.....................................SOLAR MODULES___ Hanwha 410 WattModel #Q.PEAK DUO BLK ML-G10+INVERTERINVERTER TYPE: Central:Solar Edge Single Phase HD Wave6.0 kW InverterModel #SE6000H-USSNBBL14(240V)JB(N) Junction Box(N) Solar ModuleConduitFire Setback Line14TOTAL ROOF AREA: 1198TOTAL MODULE AREA: 30825.7% OF COVERAGEIN................................(N) InverterNOTE: PV ARRAY(S) SHALL NOT EXCEED EXISTING BUILDING HEIGHTNOTE: PV DISCONNECT TO BE LOCATED WITHIN 10 FEET OF UTILITY METERUtility Company: National GridUtility Account #: 1407438029Utility Meter #: 83047322200AECOFASTEN CLAMP(REFER TO SPEC SHEET FOR DETAILS)ECOFASTEN ''L'' FOOT6''SOLAR MODULE(REFER TO SPEC SHEET FOR DETAILS)ECOFASTEN RAILSOLAR MODULE(REFER TO SPEC SHEET FOR DETAILS)(REFER TO SPEC SHEET FOR DETAILS)ECOFASTEN FLASHINGEXISTING ASPHALT SHINGLES(REFER TO ENGINEERS LETTER FOR SPECS)(REFER TO ENGINEERS LETTER FOR SPECS)(REFER TO ENGINEERS LETTER FOR SPECS)EXISTING RAFTERSCALE: NOT TO SCALEPV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOFS.S.LAG BOLTAPOC SELANTMAXSCALE: NOT TO SCALEATTACHMENT & CLIP DETAILNOTES: * REFER TO MODULE SPECS FOR MODULE DIMENSIONS * DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPENEW PV SOLAR MODULE, TYPICAL(REFER TO EQUIPMENT SCHEDULEFOR SPECS AND QUANTITIES)NEW MID CLIP. TYPICAL(REFER TO ECOFASTEN SPECIFICATION/DATASHEET FOR DETAILS)NEW END CLIP. TYPICAL(REFER TO ECOFASTEN SPECIFICATION/DATASHEET FOR DETAILS)NEW ECOFASTEN RAIL TYPICALTO BE MOUNTED PERPINDICULAR TOSTRUCTURE (REFER TO ECOFASTENSPECIFICATION / DATA SHEET FORDETAILS)NEW MOUNTING FOOT / ATTACHMENTPOINTS, TYPICAL ( REFER TOENGINEERING LETTER FOR SPACINGAND DETALIS)NOTE: PV DISCONNECT 24/7 ACCESSIBLE AND LOCKABLERoof R114 - Hanwha 410W Modules14 - S500B OptimizersPitch: 24 DegOrientation: 159 DegACINMMMSPFront of building Back o f bu i ld ing Acrebrook DrJB18' ' f ire se tback18' ' f ire se tback3' fire pathway3' fire pathway<10'aaaaaaabbbbbbbSCALE:3/32" = 1'-0" 180° 90° 270°0°SWNE PROPERTY PLANPV 2.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938......................MSP Main Service PanelINDEXAC.........................AC DisconnectMain MeterMM...............................Solar ModuleIN.......................................Inverter.................Utility Company: National GridUtility Account #: 1407438029Utility Meter #: 83047322ACINMMMSPFront o f bu i ld ing Back o f bu i ld ing Acrebrook DrPROPERTY LINE86'-7"87'-10"86'-7"86'-10"24'-7"19'-8"30'-1"55'-2"SCALE:1/16" = 1'-0" 180° 90° 270°0°SWNE INVERTERSOLAR EDGE HD WAVE 6.0 kWMODEL #SE6000H-USSNBBL14(240V)Solar Edge single phaseHD Wave 6.0 kWInverter have IntegratedDC Disconnect safety switchand Arc Fault ProtectionAtticWall DU222RBELECTRICAL ONELINE DIAGRAMPV 3.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-09381STRING: A J BOXNEMA3R27NEWNON CENTER _____MAIN C/BNOTE: Service Panel does not contain center fed Main Breaker:NEW______ MAINSERVICEPANEL120/240V,1P, 3WGEC(N) GROUNDINGELECTRODE SYSTEM200A200AHANWHA 410 WATT MODULESS500B POWER OPTIMIZERS1414(2) #10 AWG PV WIRE,(1) #6 AWG EGCFREE IN THE AIR(4) #10 AWG THWN/THWN-2(1) #10 AWG GND3/4" Conduit, 15 FEET(2) #8AWG THWN/THWN-2(1) #10 AWG THWN/THWN-2(1) #10 AWG GND3/4" Conduit, 5 FEET(4) #10 AWG THWN/THWN-2(1) #10 AWG GND3/4" Conduit, 5 FEETNOTE: CONDUIT TYPE SHALL BE CHOSEN BY THEINSTALLATION CONTRACTOR TO MEET OR EXCEEDNEC AND LOCAL AHJD REQUIREMENTSUtility Company: National GridUtility Account #: 1407438029Utility Meter #: 83047322127SolarEdge Power Optimizer S500BRated DC Input Power - 500 WattsMaximum Input Voltage - 125 VdcMPPT Range - 12.5 to 105 VdcMaximum Input Current - 15 AdcMaximum Output Current - 15 AdcString Limitations - 6 to 25 Optimizers,5700 watts STC per string maximum.Solaredge optimizers have integratedrapid shut down60A NON-FUSED AC DISCONNECT,LOCKABLE,BLADE TYPE,NEMA3R 120 / 240V(UTILITY REQUIRED)INSTALL 40A 2P CB(PV)INSTALL AT OPPOSITEEND OF BUS FROMMAIN FEEDER CBPV ARRAY RATINGWIRE SIZE CALCULATIONPV ARRAYFROM JUNCTION BOX TO INVERTERNumber Modules14Q.PEAK DUO BLK ML-G10+ 410Hanwha 410 WattMaximum Current (A)7 * 410 / 380 = 7.55Number Inverters1Solar Edge 6kW InverterSE6000H-USSNBBL14(240V)Considers Continuous (A)7.55 * 1.25 = 9.44Total DC Wattage (Watts)Watts STC, (Watts/Module) 14 * 410 = 5740Short Circuit Current (A)9.44 * 1.25 = 11.8Array CurrentsI-SC11.2AI-MP10.89ARaceway Height From Roof (Temp 39+22=61C)3 1/2"Module VoltageV-OC45.37VV-MP37.64VTemp. Derate Factor (A)11.8 / 0.71 = 16.62SYSTEM POWER#of wire(#of Strings*2)4Number Of Strings2Max Number of Modules Per String7More Than 3 CCC Adjust. Factor0.8Max DC Wattage In Strings7 * 410 = 2870 < 5700 (Watts)Max AC Voltage 120/240VAdjusted Conductor Ampacity(A)16.62 / 0.8 = 20.77FROM INVERTER TO MAIN PANELWire Size from NEC Table 310.15(b)1610 AWGTotal Current (A)25Ambient Temp Factor Per NEC Table 310.15(b)(2)(a)0.71Total AC Wattage (Watts)6000Consider Continuous (A)25 * 1.25 = 31.25Temperature Adjustment31.25 / 0.91 = 34.34Conductor Size From NEC Table 310.168 AWGMAIN PANELPV Backfeed Breaker Size (A)40Main Breaker (A)200Main Bus Rating (A)200Total Amps On Bus (120%)40 + 200 = 240 <= 240 (A)<10'(E)MAIN METERNATIONAL GRID NOTES:ANY NEW METERING AND DISCONNECT EQUIPMENT SHALL BE GROUPED, LOCATED OUTSIDE, AND 24/7 LOCKABLE ANDACCESSIBLE, IN ACCORDANCE WITH ESB 7.1.1. ALL EQUIPMENT LOCATIONS SHALL BE APPROVED BY NATIONAL GRIDMETERING DEPARTMENT PRIOR TO INSTALLATION.ALL CONSTRUCTION SHALL COMPLY WITH ESB 750 & ESB 756. INSTALLATIONS CANNOT INCLUDE ANY KIND OF TAPS,METER COLLARS OR ADAPTERS INSIDE NATIONAL GRID OWNED AND MAINTAINED EQUIPMENT, METER SOCKETS,METER CABINETS OR ANYWHERE THERE ARE UN-METERED CONDUCTORS(2) #8AWG THWN/THWN-2(1) #10 AWG THWN/THWN-2(1) #10 AWG GND3/4" Conduit, 5 FEETSTRING: B SYSTEM LABELINGDETAILSPV 4.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938(STICKER TO BE LOCATED ONCONDUIT WITH DC CURRENTEVERY 4' HORIZONTALLY OR10' VERTICALLY AND 1' FROMEACH SIDE OF A BEND)(TO BE LOCATED ONSUB-PANEL ONLYWHEN SUB-PANEL ISDEDICATED FOR PV ONLY)(STICKER LOCATEDINSIDE PANELNEXT TO SOLAR BREAKER)(STICKER LOCATEDINSIDE PANELBELOW PV BREAKER)PV ARRAYJ BOXINVERTERINTEGRATEDDC DISCONNECTPV SUB-PANEL* if applicableSUB-PANEL* if applicableACDISCONNECT* if applicableMETERMAIN SERVICEPANEL*if applicable(STICKER LOCATEDON THE PV SUB PANEL)CAUTIONAUTHORIZED SOLARPERSONNAL ONLY!CAUTIONSOLAR DC CURRENT PRESENTDURING DAYLIGHT HOURSWARNING!ELECTRIC SHOCK HAZARD.IF GROUND FAULT IS INDICATED,NORMALLY GROUNDEDCONDUCTORS MAY BE UNGROUNDED AND ENERGIZED.DC DISCONNECTDC PHOTOVOLTAIC POWER SOURCERATED MAX POWER POINT CURRENT- AMPSRATED MAX POWER POINT VOLTAGE- VOLTSMAXIMUM SYSTEM VOLTAGE- VOLTSSHORT CIRCUIT CURRENT- AMPSWARNING!ELECTRIC SHOCK HAZARD.DO NOT TOUCH THE TERMINALS.TERMINALS ON BOTH THE LINE ANDLOAD SIDES MAY BE ENERGIZED INTHE OPEN POSITION.PV LOAD CENTER SIZED FOR PVBREAKERS ONLY OR RENDERED UNABLETO ACCEPT ANY ADDITIONAL LOADS.PV SUB-PANEL ONLYAC DISCONNECTAC PHOTOVOLTAIC POWER SOURCERATED AC OUTPUT CURRENT: A MAXNOMINAL AC OPERATING VOLTAGE: 240 VacTHIS PANEL FED BYMULTIPLE SOURCES(UTILITY & SOLAR)SOLARWARNING!INVERTER OUTPUT CONNECTION. DO NOTRELOCATE THIS OVERCURRENT DEVICEPermanent directory or plaque providing location of service disconnecting means and photovoltaic systemdisconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved ormachine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanentlyattached to the equipmenq or in the required location using an approved method that is suitable to withstand theenvironment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesionrequirements of Underwriters Laboratories marking and labeling system 969(UL969).31.25LABEL 1LABEL 2LABEL 3LABEL 4LABEL 5LABEL 6LABEL 7LABEL 8LABEL 9LABEL 10LABEL 11LABEL 1287109127798107798101174512DIRECTORYMARKINGS, LABELS AND WIRING SIGNSA. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system.This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removalB. Main Service Disconnect.1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed outside cover if the main service disconnect is operable with the service panel closed.2. Commercial buildings - Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated3. Markings: Verbiage, Format and Type of Material. a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED b. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable adhesive materials meet thisrequirement.C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: 1. Markings: Verbiage, Format and Type of Material. a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies,at turns, above and for below penetrations, all DC combiners and junction boxes b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to "V. V-3b, c" of this requirement. c. Inverters are not required to have caution markings1.Marking is required on all interior and exterior DC conduit raceways,enclosures,cable assemblies,and junction boxes,combiner boxes and disconnects.2.The materials used for marking shall be reflective,weather resistant material suitable for the environment.Minimum 3/8 "letter height; all upper case letters Arial or similar font; Red background with white lettering.3.Marcking shall contain the words: WARNING : PHOTOVOLTAIC POWER SOURCE.4.Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operatedSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR ELECTRICPV PANELS10.8938048011.8 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. INSURER(S) AFFORDING COVERAGE INSURER F : INSURER E : INSURER D : INSURER C : INSURER B : INSURER A : NAIC # NAME:CONTACT (A/C, No):FAX E-MAILADDRESS: PRODUCER (A/C, No, Ext):PHONE INSURED REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. OTHER: (Per accident) (Ea accident) $ $ N / A SUBR WVD ADDL INSD THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. $ $ $ $PROPERTY DAMAGE BODILY INJURY (Per accident) BODILY INJURY (Per person) COMBINED SINGLE LIMIT AUTOS ONLY AUTOSAUTOS ONLY NON-OWNED SCHEDULEDOWNED ANY AUTO AUTOMOBILE LIABILITY Y / N WORKERS COMPENSATION AND EMPLOYERS' LIABILITY OFFICER/MEMBER EXCLUDED? (Mandatory in NH) DESCRIPTION OF OPERATIONS below If yes, describe under ANY PROPRIETOR/PARTNER/EXECUTIVE $ $ $ E.L. DISEASE - POLICY LIMIT E.L. DISEASE - EA EMPLOYEE E.L. EACH ACCIDENT EROTH-STATUTEPER LIMITS(MM/DD/YYYY)POLICY EXP(MM/DD/YYYY)POLICY EFFPOLICY NUMBERTYPE OF INSURANCELTRINSR DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) EXCESS LIAB UMBRELLA LIAB $EACH OCCURRENCE $AGGREGATE $ OCCUR CLAIMS-MADE DED RETENTION $ $PRODUCTS - COMP/OP AGG $GENERAL AGGREGATE $PERSONAL & ADV INJURY $MED EXP (Any one person) $EACH OCCURRENCE DAMAGE TO RENTED $PREMISES (Ea occurrence) COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: POLICY PRO-JECT LOC CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) CANCELLATION AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) © 1988-2015 ACORD CORPORATION. All rights reserved. CERTIFICATE HOLDER The ACORD name and logo are registered marks of ACORD HIRED AUTOS ONLY 5/29/2024 Arthur J.Gallagher Risk Management Services,LLC 300 Fellowship Road Suite 200 Mount Laurel NJ 08054 Alexander Gillikin 856-482-9900 856-482-1888 CherryHill.BSD.CertM@AJG.com Gotham Insurance Company 25569 TRINHEA-03 National Union Fire Insurance Company of Pittsburg 19445TrinitySolar,LLC 4 Open Square Way,Suite 410 Holyoke,MA 01040 Endurance American Specialty Ins Co 41718 Liberty Insurance Underwriters Inc 19917 Columbia Casualty Company 31127 1145849548 A X 2,000,000 X 100,000 5,000 1,000,000 2,000,000 X GL202100013378 6/1/2023 6/1/2025 2,000,000 B 2,000,000 X CA 2960145 6/1/2024 6/1/2025 A C D E X 5,000,000 X EX202300001871 ELD30006989102 1000231834-08 7039650582 6/1/2023 6/1/2024 6/1/2024 6/1/2024 6/1/2025 6/1/2025 6/1/2025 6/1/2025 5,000,000 Limit x of $5,000,000 19,000,000 B X N WC 013588107 6/1/2024 6/1/2025 1,000,000 1,000,000 1,000,000 B Automobile Comp/Collusion Ded.CA 2960145 6/1/2024 6/1/2025 All Other Units Truck-Tractors and Semi-Trailers $250/$500 $250/$500 Evidence of insurance. Evidence of Insurance INVERTERDATA SHEETD 5.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938 POWER OPTIMIZERDATA SHEETD 6.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938 MODULEDATA SHEETD 7.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938 RACKINGDATA SHEETD 8.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938 ATTACHMENTDATA SHEETD 9.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938 AC DISCONNECTDATA SHEETD 10.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioProject Name:Property Address:09/11/2024Rosalyn Devincentis160 Acrebrook Dr,Florence, MA 01062DATE:CONTRACTORTrinity SolarAddress: 2211 Allenwood Road WallTownship, NJ 07719Phone number: 888-865-7300Phone Number:(310) 928-0938