Loading...
optimizersPOWER OPTIMIZERSolarEdge Power Optimizer Module Add-On For North America P320 / P370 / P400 / P405 Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Compliant with arc fault protection and rapid shutdown NEC requirements (when installed as part of the SolarEdge system) Module-level voltage shutdown for installer and firefighter safety PV power optimization at the module-level www.solaredge.usUSA ͳ CANADA ͳ 'ERMANY ͳ ITALY ͳ FRANCE ͳ :APAN ͳ CHINA ͳ AUSTRALIA ͳ THE NETHERLANDS ͳ U< ͳ ISRAEL ͳ TUR<EY ͳ SOUTH AFRICA ͳ BUL'ARIA ͳ INDIA OPTIMIZER MODEL (typical module compatibility) P320 (for high-power 60-cell modules) P370 (for higher-power 60 and 72-cell modules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) INPUT Rated Input DC Power(1)320 370 400 405 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 125 Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 12.5 - 105 Vdc Maximum Short Circuit Current (Isc) 11 10.1 Adc Maximum DC Input Current 13.75 12.63 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H)128 x 152 x 28 / 5 x 5.97 x 1.1 128 x 152 x 36 / 5 x 5.97 x 1.42 128 x 152 x 50 / 5 x 5.97 x 1.96 mm / in Weight (including cables)630 / 1.4 750 / 1.7 845 / 1.9 gr / lb Input Connector MC4 Compatible MC4 / Amphenol AH4 MC4 Compatible Output Wire Type / Connector Double Insulated; MC4 Compatible Double Insulated; MC4 / Amphenol AH4 Double Insulated; MC4 Compatible Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. SolarEdge Power Optimizer Module Add-On for North America P320 / P370 / P400 / P405 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(2)(3) SINGLE PHASE HD-WAVE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power Optimizers) P320, P370, P400 8 10 18 P405 6 8 14 Maximum String Length (Power Optimizers)25 25 50(4) Maximum Power per String 5700 (6000 with SE7600H-US)5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 10/2017 V.02. Subject to change without notice. (2) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf. (3) It is not allowed to mix P405 with P320/P370/P400/P600/P700/P800 in one string. (4) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement