Loading...
Schumacher - Structural LetterWESTSHORE DESIGN ENGINEERS, P.C. 6279 JOHNSTON RD. ALBANY Ϳ NEW YORK Ϳ 12203 WestShore Design Engineers ۅ 6279 Johnston Rd. ۅ Albany, NY 12203 Subject: Schumacher Residence 21 West Parsons Lane Northampton, MA To Whom It May Concern, The following references the Schumacher Residence in Northampton, MA: 1. Existing roof framing: Conventional framing is 2x8 at 16”o.c. with collar ties a`nd a 15’ span (horizontal rafter projection). This existing structure is capable to support all the loads that are indicated below for this photovoltaic project. 2. Roof Loading: - 4psf dead load (modules plus mounting hardware) - 40psf ground snow load - 6.2psf roof materials (2.2psf 2x8, 1.5psf sheathing, 2.5psf asphalt shingles) - Exposure Category B, 125mph wind (3 sec.) This installation design will be in general conformance to the manufacturer’s specifications, and complies with all applicable laws, codes, and ordinances, specifically the International Building Code/IBC 2015 and International Residential Code/IRC 2015 including all MA regulations and amendments. The spacing and fastening of the mounting brackets is to have a maximum of 48”o.c. span between mounting brackets, staggered, and secured using 5/16” diameter corrosive resistant steel lag bolts. Thank you. Westshore Design Engineers June 18, 2024 John Eibert Nicolas Nitti, PE Director of Solar Operations. President To: Insight Solar 59C North St. Hatfield, MA 01038 Date: June 18, 2024 Ref.: 24060273