04-M-SCI02.Conformed Plumbing- Prospect Place-100% CD Building_Permit_SetACAIR CONDITIONING UNITAFFABOVE FINISH FLOORAFCABOVE FINISH CEILINGAHUAIR HANDLING UNITBODBOTTOM OF DUCTBOTBOTTOMCACOMBUSTION AIRCBVCIRCUIT BALANCING VALVECOCLEAN OUTCPCONDENSATE PUMPCUCONDENSING UNITCHCABINET HEATERDCWSDOMESTIC COLD WATER SUPPLYDHWSDOMESTIC HOT WATER SUPPLYDHWRDOMESTIC HOT WATER RETURNDNDOWNEAEXHAUST AIREDHELECTRIC DUCT HEATEREERENERGY EFFICIENCY RATIOEFEXHAUST FANERVENERGY RECOVERY VENTILATORETEXPANSION TANKEUHELECTRIC UNIT HEATEREXIST.EXISTING.FC.FLEXIBLE CONNECTIONFCUFAN COIL UNITFLFLOORFDFIRE DAMPERFTRFIN TUBE RADIATIONHCHEATING COILHPHORSEPOWERHVHEATING AND VENTILATING UNITHTWHIGH TEMPERATURE WATERHTWSHIGH TEMPERATURE WATER SUPPLYHTWRHIGH TEMPERATURE WATER RETURNLDLINEAR CEILING DIFFUSERLBS/HRPOUNDS PER HOURMWMAKE-UP WATERMAX.MAXIMUMMIN.MINIMUMNOM.NOMINALOAOUTDOOR AIRPPUMPPRVPRESSURE REDUCING VALVERARETURN AIRRFRETURN FANRHRELATIVE HUMIDITYS&RSUPPLY AND RETURNSASUPPLY AIRSDSMOKE DAMPERSPSTATIC PRESSURESUSP. CLG.SUSPENDED CEILINGUHUNIT HEATERUVUNIT VENTILATORVDVOLUME DAMPERVFDVARIABLE FREQUENCY DRIVES.G. SUCTION GUIDET.D.V.TRIPLE DUTY VALVEN.C.NORMALLY CLOSEDN.O.NORMALLY OPENPLUMBING LEGENDGENERAL PLUMBING NOTESKEYED EQUIPMENT LEGENDTYPICAL ABBREVIATIONS1.CONTRACTOR(S) SHALL PROVIDE ALL ITEMS, ARTICLES, EQUIPMENT, TOOLS, APPLIANCES, MATERIALS AND METHODS REQUIRED FOR COMPLETED SYSTEMS.2.PROVIDE ALL LABOR, SCAFFOLDING SUPPORTS, SUPERVISION AND INCIDENTALS REQUIRED TO MODIFY AND/OR INSTALL THE SYSTEMS COMPLETE.3.CONTRACTOR(S) SHALL LOCATE AND PROTECT THE OWNER'S EQUIPMENT, PIPING AND UTILITIES SCHEDULED TO REMAIN FROM DAMAGE DURING CONSTRUCTION ASCOORDINATED BY THE CM AND TRADE CONTRACTORS.4.ALL WORK SHALL BE EXECUTED BY SKILLED MECHANICS IN THE APPLICABLE TRADES INVOLVED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND APPROVEDMANUFACTURER'S INSTALLATION REQUIREMENTS FOR INSTALLING, CONNECTING AND ADJUSTING ALL EQUIPMENT.5.CONTRACTOR(S) SHALL FIELD VERIFY ALL DIMENSIONS OF EXISTING ELEMENTS, EQUIPMENT, AND OTHER CONDITIONS HAVING A BEARING ON THE WORK. CONTRACTOR(S)SHALL COORDINATE WITH OTHER TRADES TO ELIMINATE ANY INTERFERENCES WITH LIGHTING FIXTURES, DUCTWORK, PIPING, ETC. SEE COORDINATION DRAWINGSPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.6.CONTRACTOR(S) SHALL PERFORM ALL VERIFICATIONS, OBSERVATIONS, TESTS, AND EXAMINATIONS OF THE WORK PRIOR TO THE ORDERING OF ANY EQUIPMENT AND THEACTUAL CONSTRUCTION.7.8.CONTRACTOR(S) SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALLPORTIONS OF THE WORK UNDER CONTRACT, UNLESS OTHERWISE NOTED.9.CONTRACTOR(S) SHALL FURNISH AND INSTALL ALL MATERIALS AS REQUIRED FOR COMPLETE SYSTEMS, INCLUDING ALL PARTS OBVIOUSLY OR REASONABLY INCIDENTAL TO ACOMPLETE INSTALLATION, WHETHER SPECIFICALLY INDICATED OR NOT.10.FOLLOW MANUFACTURERS' INSTRUCTIONS FOR INSTALLING, CONNECTING AND ADJUSTING ALL EQUIPMENT.11.DRAWINGS ARE NOT TO BE SCALED. DRAWINGS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED.12.DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELDVERIFY DIMENSIONS. SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS AND/OR DESIGN INTENT, THE CONTRACTOR SHALLBE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE OWNER PRIOR TO PROCEEDING WITH THE WORK.13.DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONSSHALL BE INCLUDED AS PART OF THE WORK.14.A HOSE BIB SHALL BE INSTALLED IN EACH TOILET ROOM EQUIPPED WITH TWO OR MORE TOILETS OR URINALS OR ANY COMBINATION THEREOF.15.ALL FLOOR DRAINS SHALL BE EQUIPPED WITH AN AUTOMATIC TRAP PRIMING DEVICE.16.REFER TO ARCHITECTURAL DRAWINGS FOR FIXTURE MOUNTING HEIGHTS. COORDINATE FLUSH VALVE HEIGHT WITH APPLICABLE FIXTURE MOUNTING HEIGHT PRIOR TOSUBMITTING SHOP DRAWINGS.17.ALL EXPOSED WASTE AND POTABLE WATER PIPING AT ADA FIXTURES SHALL BE COVERED/INSULATED WITH UNDERSINK PIPING COVER SYSTEM, AS MANUFACTURED BYTRUEBRO, OR EQUAL.18.CONTRACTORS SHALL PREPARE AND SUBMIT COORDINATED SHOP DRAWINGS FOR OWNER'S, ARCHITECT'S AND ENGINEER'S REVIEW. NOTE THAT CONTRACT DRAWINGS ARESCHEMATIC ONLY, AND CONTRACTOR SHALL NOT SCALE DRAWINGS OR BUILD FROM AS SHOWN.a.CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL FIELD CONDITIONS AND INSTALL EQUIPMENT AND SYSTEMS TO MEET ALL REQUIRED CLEARANCES AND PROVIDESALL NECESSARY ACCESS. CONTRACTOR SHALL FIELD DETERMINE FINAL LOCATIONS AND ELEVATIONS THAT BEST SUITS THE NEEDS OF THE PROJECT.b.COORDINATED SHOP DRAWINGS SHALL BE DRAWN TO A SCALE NOT SMALLER THAN 3/8 INCH EQUALS 1 FOOT. DRAWING SHEETS SHALL BE SAME SIZE AS THE CONTRACTDRAWINGS. COORDINATED SHOP DRAWINGS SHALL DEPICT FABRICATION, ASSEMBLY, AND INSTALLATION DETAILS. DRAWINGS SHALL SHOW EQUIPMENT/SYSTEM PLANS,ELEVATIONS AND SECTIONS. DETAILS OF COMPONENTS, AND ATTACHMENTS TO OTHER WORK SHALL ALSO BE INCLUDED.c.THE MC SHALL PREPARE A FIRST SUBMISSION OF DUCTWORK SHOP DRAWINGS TO 3/8" SCALE. THESE DRAWINGS ARE TO INCORPORATE ALL DUCTWORK (INCLUDINGBOTTOM OF DUCT ELEVATIONS), EQUIPMENT AND ACCESSORIES AS SPECIFIED AND SHOWN ON THE CONTRACT DRAWINGS. ALL EXISTING AND PROPOSED PENETRATIONSTHROUGH WALLS, FLOOR AND DECKS MUST BE SHOWN ON THE DRAWINGS.d.ALL CONFLICTS WITH BUILDINGS' CONSTRUCTION WILL BE RESOLVED BY THE GC/CM. THE MC WILL THEN FORWARD THE DUCTWORK SHOP DRAWINGS TO THE GC/CM. THEGC/CM WILL FORWARD THE DUCTWORK SHOP DRAWINGS TO THE PC.e.THE PC WILL INCORPORATE HIS/HER SCOPE OF WORK ON THE 3/8" DUCTWORK SHOP DRAWINGS ILLUSTRATING ALL PLUMBING EQUIPMENT, PIPING, HANGERS, ETC. THEGC/CM WILL FORWARD THE FINAL DUCTWORK/PLUMBING/ MC SHOP DRAWING TO THE EC.f.THE EC WILL INCORPORATE ALL ELECTRICAL EQUIPMENT INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, SWITCHGEAR, CONDUIT & HANGERS. THE GC/CM WILLFORWARD THE FINAL DUCTWORK/PLUMBING/MC/EC SHOP DRAWINGS TO THE FIRE PROTECTION CONTRACTOR (FP).g.THE FP WILL INCORPORATE ALL SPRINKLER EQUIPMENT, PIPING, HANGERS AND SPRINKLER HEADS AS REQUIRED BY CODE. GC/CM SHALL THEN, AND ONLY THEN,DISBURSE TO THE DESIGN TEAM FOR REVIEW.19.ANY PIPING, DUCTS OR CONDUIT THAT PENETRATE RATED WALL, CEILING OR FLOOR ASSEMBLIES SHALL BE SEALED WITH APPROVED FIRESTOPPING MATERIAL TO MAINTAINFIRE RATING AS REQUIRED BY CODE. PENETRATIONS THROUGH NON-RATED ASSEMBLIES MAY BE SEALED WITH SILICONE CAULK. ALL PLUMBING, ELECTRICAL AND HVACPENETRATIONS MUST BE SEALED BY THE RESPECTIVE TRADE CONTRACTOR.20.PROVIDE WATER HAMMER ARRESTOR AT END OF DCWS & DHWS BRANCH PIPING TO EACH SINK OR GROUPS OF SINKS EQUIPPED WITH ELECTRONIC FAUCETS & EACH GROUPOF WATER CLOSETSFIXTURE MINIMUM PIPE SIZE SCHEDULELV-xWC-xTAG1/2"DCWSSEE NOTES 1 & 3 DHWS-REMARKSWATER PIPING1/2"1/2"HB-x3/4"-MS-13/4"3/4"FD-xVENTWASTESOILDRAINAGE PIPING2"-NOTE 21-1/2"1-1/4"1-1/2"1-1/2"3"NOTE 4--FIXTURELAVATORYHOSE BIBWATER CLOSETMOP SINKFLOOR DRAINKS-xKITCHEN SINK1/2"-----1/2"1/2"1-1/4"1-1/2"-4. 3. 2. PROVIDE ISOLATION VALVE OR SUPPLY/STOPS IN WATER PIPING TO EACH FIXTURE.SOIL PIPING SIZE SHALL BE CONSISTENT WITH THE FIXTURE OUTLET SIZE.SIZES SHOWN ARE FOR PIPING CONNECTIONS TO INDIVIDUAL FIXTURES ONLY. SEE PLANS FORBRANCH/RISER SIZING FOR MULTIPLE FIXTURES.SEE PLUMBING SCHEDULES FOR FLOOR DRAIN PIPE SIZES.NOTES:1. HPWHXKSXLVXWCXFDXSHXDOMESTIC HOT WATER RETURN PIPING (DHWR)DOMESTIC COLD WATER SUPPLY PIPING (DCWS)DOMESTIC HOT WATER SUPPLY PIPING (DHWS)VENT PIPINGSOIL/WASTE PIPING (BELOW SLAB OR FIN FLOOR)SOIL/WASTE PIPING (ABOVE SLAB)FLOOR CLEANOUT (C.O.)WALL OR PIPE CLEANOUT (C.O.)FLOOR DRAINBALL VALVECHECK VALVEPIPE CAPUNIONTHERMOMETERPRESSURE GAUGESTRAINER W/ BLOWDOWN VALVE & CAPWATER HAMMER ARRESTORGAS COCKFLEXIBLE CONNECTORHEAT PUMP WATER HEATERLAVATORYWATER CLOSETFLOOR DRAINKITCHEN SINKSHOWERC.O.C.O.ETP1EXPANSION TANKRCP1RECIRCULATION PUMPTMV1THERMOSTATIC MIXING VALVEPUMPCONDENSATE PIPINGSH-xSHOWER-1/2"1/2"1-1/4"2"CIRCUIT BALANCING VALVEWATER HAMMER ARRESTOR (DHWS)WATER HAMMER ARRESTOR (DCWS)WHA-1WHA-2HB1HOSE BIBB- EXTERIOR, FREEZE-PROOFFDDWSTXDOMESTIC WATER STORAGE TANKSTXSWING TANKSPXSUMP PUMPOSXOIL-WATER SEPARATORTYPE:FGFIBROUS GLASS INSULATIONTYPEPIPE AND EQUIPMENT INSULATION SCHEDULELOCATIONTEMP. RANGE (°F)SERVICEPIPE SIZETHICKNESSSUPPLEMENTALPVC JACKETREMARKSDHWS/RDCWS105°-140°±ALL45°±FGNOTES:1.INSULATE ROOF DRAIN SUMP WITH 12" THICK CLOSED-CELL INSULATION1/2" - 1-1/4"1"1-1/2" & LARGER1-1/2"1/2" - 1-1/4"1/2"1-1/2" & LARGER1"NONO--CONDENSATE-NO-ALL1/2"PROSPECT PLACE737 BRIDGE ROADPARCEL 18C-048-001737 BRIDGE ROADJANUARY 9, 2023M-SCI02LBMTSCALE:REVISIONS:No.DATESEAL:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:SCALE:REVISIONS:No.DATEDESCRIPTIONSEAL:2A RIVER STREETADAMS, MA 01220P: (413) 743.9500F: (413) 743.3313www.HESNOR.comTHESE DRAWINGS (INSTRUMENTS OF SERVICE) WERE PREPARED IN A
DESIGN-BUILD FASHION WITH A COLLABORATION BETWEEN HESNOR
ENGINEERING ASSOCIATES, PLLC AND SALOOMEY CONSTRUCTION.
THESE INSTRUMENTS OF SERVICE ARE FOR USE SOLELY BY SALOOMEY
CONSTRUCTION. ANY UNAUTHORIZED USE OF THE INSTRUMENTS OF
SERVICE SHALL BE AT THE OWNER'S SOLE RISK AND WITHOUT LIABILITY
TO HESNOR ENGINEERING ASSOCIATES, PLLC OR SALOOMEY
CONSTRUCTION.CITY OF NORTHAMPTONHAMPSHIRE COUNTYMASSACHUSETTSM-SCI02.A02/14/24PRIOR REVISIONSB02/14/24CONFORMED SETREVISIONS02/24/24100% CD PERMIT SET-P0.00PLUMBING NOTES &LEGENDSN.T.S.P0.00
1413MLKJHGF10EDCB14985431A13121176ABCDE5FGHJK10965LM1211875431KS1LV1SH1WC1SEE ENLARGED MECHANICALPLAN ON SHEET P5.021-1/4" DCWS1-1/4" DHWS3/4" DHWR1-1/2" DCWS1-1/2" DHWS3/4" DHWR2-1/2" DCWS2-1/2" DHWS1-1/4" DHWR1-1/2" DCWS1-1/2" DHWS3/4" DHWR1-1/4" DCWS1-1/4" DHWS3/4" DHWR2-1/2" DCWS2-1/2" DHWS1-1/4" DHWR1-1/4" DCWS1-1/4" DHWS3/4" DHWR3" DCWS3" DHWS1-1/2" DHWR2-1/2" DCWS2-1/2" DHWS3/4" DHWR4" DCWS4" DHWS2" DHWR4" DCWS4" DHWS2" DHWR1-1/4" DCWS1-1/4" DHWS3/4" DHWRSHEET KEYED NOTES3/4" DCWS, 3/4" DHWS & 1/2" DHWR PIPING UP- PROVIDE DCWS, DHWS & DHWR ISOLATION VALVES IN CORRIDOR CEILINGPRIOR TO RISER3/4" DCWS & 3/4" DHWS PIPING UPOMITTED1/2" DHWS TO WASHING MACHINE(S)- SEE DETAIL ON SHEET P5.011/2" DCWS & 1/2" DHWS UPPROVIDE 1/2" DCWS FOR TRAP PRIMER AT FLOOR DRAIN- ROUTE TRAP PRIMER PIPING BELOW FIN FL- SIOUX CHIEF, MODEL No. 695 OR EQUALLV1SH1WC1LV2WC1LV1SH1WC1KS10.5GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM0.5GPM 0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM 0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM 3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR1/2" DCWS1/2" DHWS1/2" DHWR0.5 GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5 GPM3/4" DCWS3/4" DHWS1/2" DHWR2-1/2" DCWS2-1/2" DHWS1-1/4" DHWR1-1/4" DCWS1-1/4" DHWS3/4" DHWR1-1/2" DCWS1-1/2" DHWS3/4" DHWR2-1/2" DCWS2-1/2" DHWS1-1/4" DHWR0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5
GPM
0.5
GPM 0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5
GPM
3/4" DCWS3/4" DHWS1/2" DHWR0.5
GPM0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR0.5
GPM
3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS1/2" DHWS1/2" DHWR0.5GPM0.5 GPM2-1/2" DCWS2-1/2" DHWS1-1/4" DHWR3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR0.5
GPM0.5GPMROUTE PIPING TO AVOIDCROSSING SKYLIGHTS- OFFSET FOR CLARITY0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR1-1/2" DCWS1-1/2" DHWS3/4" DHWR3/4" DCWS1/2" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR1/2" DCWS1/2" DHWS1/2" DHWRINSTALL CIRCUIT BALANCING VALVE &CHECK VALVES IN CORRIDOR (TYP. ALLLOCATIONS)- OFFSET FOR CLARITY3/4"HB13/4"HB13/4"HB13/4"HB1HB13/4"HB13/4"HB13/4"HB13/4"HB13/4"HB13/4"HB1HB13/4"HB13/4"3/4"HB1HB13/4"FD1FD1PROSPECT PLACE737 BRIDGE ROADPARCEL 18C-048-001737 BRIDGE ROADJANUARY 9, 2023M-SCI02LBMTSCALE:REVISIONS:No.DATESEAL:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:SCALE:REVISIONS:No.DATEDESCRIPTIONSEAL:2A RIVER STREETADAMS, MA 01220P: (413) 743.9500F: (413) 743.3313www.HESNOR.comTHESE DRAWINGS (INSTRUMENTS OF SERVICE) WERE PREPARED IN A
DESIGN-BUILD FASHION WITH A COLLABORATION BETWEEN HESNOR
ENGINEERING ASSOCIATES, PLLC AND SALOOMEY CONSTRUCTION.
THESE INSTRUMENTS OF SERVICE ARE FOR USE SOLELY BY SALOOMEY
CONSTRUCTION. ANY UNAUTHORIZED USE OF THE INSTRUMENTS OF
SERVICE SHALL BE AT THE OWNER'S SOLE RISK AND WITHOUT LIABILITY
TO HESNOR ENGINEERING ASSOCIATES, PLLC OR SALOOMEY
CONSTRUCTION.CITY OF NORTHAMPTONHAMPSHIRE COUNTYMASSACHUSETTSM-SCI02.A02/14/24PRIOR REVISIONSB02/14/24CONFORMED SETREVISIONS02/24/24100% CD PERMIT SET-P1.10FIRST FLOORDOMESTIC WATERPLUMBING PLAN1/8" = 1'-0"P1.10
1413ML10KKJHGF10EDCB14984321AA13121176BCDE5FGHJ965M1211874321LSKYLIGHTSKYLIGHTSKYLIGHTSKYLIGHTSKYLIGHTSKYLIGHTSHEET KEYED NOTES3/4" DCWS, 3/4" DHWS & 1/2" DHWR PIPING FROM BELOW3/4" DCWS, 3/4" DHWS PIPING FROM BELOWCIRCUIT BALANCING & CHECK VALVE- PROVIDE 16"x16", STAINLESS STEEL, HINGED, LOCKABLE ACCESS DOOR1/2" DHWS TO WASHING MACHINE(S)- SEE DETAIL ON SHEET P5.011/2" DCWS & 1/2" DHWS FROM BELOWLV1SH1WC1LV1SH1WC1KS1KS1SEE WASHINGMACHINE HOOKUPDETAIL ON SHEET P5.013/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR1/2" DCWS1/2" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWRALL VALVES TO BE LOCATED ABOVECLOSET SPACE/BATHROOM CEILINGAS APPLICABLE (TYP. THIS FLOOR)- PIPING & VALVES OFFSET FORCLARITY0.5GPM0.5GPM0.5GPM0.5 GPM0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5
GPM 0.5 GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5 GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5 GPM0.5 GPM3/4" DCWS3/4" DHWS1/2" DHWR0.5 GPM
3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM0.5 GPM0.5GPM0.5GPM0.5GPM0.5
GPM
0.5
GPM
0.5GPM0.5 GPM0.5 GPM0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR1/2" DCWS1/2" DHWS1/2" DHWR0.5
GPM 3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR0.5GPM0.5GPM0.5GPM3/4" DCWS3/4" DHWS1/2" DHWR3/4" DCWS3/4" DHWS1/2" DHWR0.5
GPM 3/4" DCWS3/4" DHWS1/2" DHWRPROSPECT PLACE737 BRIDGE ROADPARCEL 18C-048-001737 BRIDGE ROADJANUARY 9, 2023M-SCI02LBMTSCALE:REVISIONS:No.DATESEAL:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:SCALE:REVISIONS:No.DATEDESCRIPTIONSEAL:2A RIVER STREETADAMS, MA 01220P: (413) 743.9500F: (413) 743.3313www.HESNOR.comTHESE DRAWINGS (INSTRUMENTS OF SERVICE) WERE PREPARED IN A
DESIGN-BUILD FASHION WITH A COLLABORATION BETWEEN HESNOR
ENGINEERING ASSOCIATES, PLLC AND SALOOMEY CONSTRUCTION.
THESE INSTRUMENTS OF SERVICE ARE FOR USE SOLELY BY SALOOMEY
CONSTRUCTION. ANY UNAUTHORIZED USE OF THE INSTRUMENTS OF
SERVICE SHALL BE AT THE OWNER'S SOLE RISK AND WITHOUT LIABILITY
TO HESNOR ENGINEERING ASSOCIATES, PLLC OR SALOOMEY
CONSTRUCTION.CITY OF NORTHAMPTONHAMPSHIRE COUNTYMASSACHUSETTSM-SCI02.A02/14/24PRIOR REVISIONSB02/14/24CONFORMED SETREVISIONS02/24/24100% CD PERMIT SET-P1.20SECOND FLOORDOMESTIC WATERPLUMBING PLAN1/8" = 1'-0"P1.20
1413MLKJHGF10EDCB14985431A13121176ABCDE5FGHJK10965LM1211875431KEYED NOTES:1-1/2" WASTE PIPING FROM ABOVE2" WASTE PIPING FROM ABOVE4" SOIL PIPING FROM ABOVE3" WASTE PIPING FROM ABOVE3/4" CONDENSATE FROM 2ND FLOOR ABOVE1" CONDENSATE FROM ABOVEROUTE CONDENSATE TO SPILL AT EXTERIORROUTE CONDENSATE TO SPILL AT MOP SINKLINT INTERCEPTOR-ZURN, MODEL NO. Z1185 WITH 3" INLET/OUTLET-FIELD VERIFY EXACT LOCATIONTHIS SHEETFD24"C.O.FD12"2"2"4"4"2"
4"4"4"4"4"2"4"4"2"2"4"4"4"4"SP1OS1OIL SEPARATOR (TYP.)- SEE DETAIL ON SHEET P5.02- APPROX. LOCATION SHOWN.VERIFY EXACT LOCATION INFIELDSP1OS1NOTES:SEE DOMESTIC WATER PLANS FOR ADDITIONAL FIXTURE TAGSEXISTING BELOW SLAB PIPING SHOWN ON DRAWINGS IS BASEDON PIPE TRACING/SCOPING PERFORMED BY OTHERS. NOT ALLEXISTING BRANCH LINES AND ASSOCIATED INVERTS HAVEBEEN VERIFIED. CONTRACTOR TO FIELD VERIFY PRIOR TOINSTALLATION.THIS SHEET4"2"2"4"FD1FD24"4"4
"
2"
2"
2"
4"FD12
"
2
"C.O.4"2"
4"
4"2"2"2"2
"
3"
4"4"1
"1-1/4"1-1/4"1-1/4"1"1"1"1"1-1/4"1-1/4"1"1-1/4"1-1/4"1"1"1"ROUTE CONDENSATEPIPING TO FLOOR DRAIN1"1-1/4"1-1/4"1
"1-1/4"1-1/4"1"1"1-1/4"1-1/4"1"
OSAPOSAPOIL SEPARATOR ALARMPANELS-FIELD COORDINATEEXACT LOCATION WITHOWNER'S REP. & ECSUMP PUMP ALARMPANELS (TYP. OF 2)-FIELD COORDINATEEXACT LOCATION1-1/4"1"1-1/4"1"1"1-1/4"1"1"1"1-1/4"1"1-1/4"1"1"1"4"4"4"
2"
4"C.O.C.O.C.O.4"4"C.O.C.O.C.O.C.O.4"4"4"4"4"2"C.O.C.O.C.O.C.O.C.O.3"C.O.4"2"4"4"C.O.4"4"4"C.O.2"C.O.2"C.O.C.O.C.O.1-1/4"3/4"CHASE BY GCC.O.3"C.O.C.O.C.O.C.O.C.O.C.O.C.O.C.O.C.O.C.O.C.O.C.O.C.O.C.O.C.O.C.O.CHASE BY GCEXISTING BELOW SLABSANITARY PIPING (TYP.)- SEE NOTE 21.2.4"C.O.3"4"4"4"
2"2"2"2"
4"4"2
"4"2"4"2"4"2"2"2"3"3"PROSPECT PLACE737 BRIDGE ROADPARCEL 18C-048-001737 BRIDGE ROADJANUARY 9, 2023M-SCI02LBMTSCALE:REVISIONS:No.DATESEAL:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:SCALE:REVISIONS:No.DATEDESCRIPTIONSEAL:2A RIVER STREETADAMS, MA 01220P: (413) 743.9500F: (413) 743.3313www.HESNOR.comTHESE DRAWINGS (INSTRUMENTS OF SERVICE) WERE PREPARED IN A
DESIGN-BUILD FASHION WITH A COLLABORATION BETWEEN HESNOR
ENGINEERING ASSOCIATES, PLLC AND SALOOMEY CONSTRUCTION.
THESE INSTRUMENTS OF SERVICE ARE FOR USE SOLELY BY SALOOMEY
CONSTRUCTION. ANY UNAUTHORIZED USE OF THE INSTRUMENTS OF
SERVICE SHALL BE AT THE OWNER'S SOLE RISK AND WITHOUT LIABILITY
TO HESNOR ENGINEERING ASSOCIATES, PLLC OR SALOOMEY
CONSTRUCTION.CITY OF NORTHAMPTONHAMPSHIRE COUNTYMASSACHUSETTSM-SCI02.A02/14/24PRIOR REVISIONSB02/14/24CONFORMED SETREVISIONS02/24/24100% CD PERMIT SET-P2.10FIRST FLOORDRAIN PIPINGPLUMBING PLAN1/8" = 1'-0"P2.10N.F.C - FOR REVIEW ONLY
1413ML10KKJHGF10EDCB14984321AA13121176BCDE5FGHJ965M1211874321LSKYLIGHTSKYLIGHTSKYLIGHTSKYLIGHTSKYLIGHTSKYLIGHTKEYED NOTES:1-1/2" WASTE PIPING DOWN2" WASTE PIPING DOWN4" SOIL PIPING DOWN3" WASTE PIPING DOWN3/4" CONDENSATE PIPING DOWNROUTE 3/4" CONDENSATE TO SPILL AT MOP SINK1" CONDENSATE PIPING DOWNTHIS SHEETFD1FD1NOTES:SEE DOMESTIC WATER PLANS FOR ADDITIONAL FIXTURE TAGSTHIS SHEETLINT INTERCEPTOR- ZURN, MODEL No. Z1185 WITH3" INLET/OUTLET- FIELD VERIFY EXACTLOCATIONLINT INTERCEPTOR- ZURN, MODEL No. Z1185 WITH3" INLET/OUTLET- FIELD VERIFY EXACTLOCATIONHEAT PUMP BYMC (TYP.)4"4"4"2"PROSPECT PLACE737 BRIDGE ROADPARCEL 18C-048-001737 BRIDGE ROADJANUARY 9, 2023M-SCI02LBMTSCALE:REVISIONS:No.DATESEAL:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:SCALE:REVISIONS:No.DATEDESCRIPTIONSEAL:2A RIVER STREETADAMS, MA 01220P: (413) 743.9500F: (413) 743.3313www.HESNOR.comTHESE DRAWINGS (INSTRUMENTS OF SERVICE) WERE PREPARED IN A
DESIGN-BUILD FASHION WITH A COLLABORATION BETWEEN HESNOR
ENGINEERING ASSOCIATES, PLLC AND SALOOMEY CONSTRUCTION.
THESE INSTRUMENTS OF SERVICE ARE FOR USE SOLELY BY SALOOMEY
CONSTRUCTION. ANY UNAUTHORIZED USE OF THE INSTRUMENTS OF
SERVICE SHALL BE AT THE OWNER'S SOLE RISK AND WITHOUT LIABILITY
TO HESNOR ENGINEERING ASSOCIATES, PLLC OR SALOOMEY
CONSTRUCTION.CITY OF NORTHAMPTONHAMPSHIRE COUNTYMASSACHUSETTSM-SCI02.A02/14/24PRIOR REVISIONSB02/14/24CONFORMED SETREVISIONS02/24/24100% CD PERMIT SET-P2.20SECOND FLOORDRAIN PIPINGPLUMBING PLAN1/8" = 1'-0"P2.20
1413MLKJHGF10EDCB14985431A13121176ABCDE5FGHJK10965LM1211875431KEYED NOTES:CONNECT VENT STACK TO BUILDING SANITARY SOIL/WASTE PIPING2" VENT PIPING UP2-1/2" VENT PIPING UPTHIS SHEET2" VTR2"2"1-1/4"2"2"2"2"
2"
1-1/4"1-1/2"1-1/4"2"1-1/4"1-1/4"2"1-1/4"1-1/4"1-1/4"1-1/4"2"1-1/4"1-1/4"1-1/4"1-1/4"1-1/4"2"1-1/4"1-1/4"1-1/4"1-1/2"2"2"OIL SEPARATOR (TYP. OF 2)- SEE DETAIL ON SHEET P5.02NOTES:1.SEE DOMESTIC WATER PLANS FOR ADDITIONAL FIXTURE TAGSTHIS SHEET2"1-1/4"2"2"1-1/4"1-1/4"1-1/4"1-1/2"1-1/2"2-1/2"2"2" VTR2"
1-1/4"1-1/4"
2"
2"1-1/4"1-1/4"
2"
1-1/2"
2"2"2"1-1/4"1-1/4"1-1/4"
1-1/4"2"2"2"1-1/2"1-1/4"2"1-1/4"2"1-1/2"2"2"2"2"2"1-1/4"1-1/2"1-1/4"
1-1/4"2"1-1/2"
1-1/2"
2"2" VTR2"PROSPECT PLACE737 BRIDGE ROADPARCEL 18C-048-001737 BRIDGE ROADJANUARY 9, 2023M-SCI02LBMTSCALE:REVISIONS:No.DATESEAL:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:SCALE:REVISIONS:No.DATEDESCRIPTIONSEAL:2A RIVER STREETADAMS, MA 01220P: (413) 743.9500F: (413) 743.3313www.HESNOR.comTHESE DRAWINGS (INSTRUMENTS OF SERVICE) WERE PREPARED IN A
DESIGN-BUILD FASHION WITH A COLLABORATION BETWEEN HESNOR
ENGINEERING ASSOCIATES, PLLC AND SALOOMEY CONSTRUCTION.
THESE INSTRUMENTS OF SERVICE ARE FOR USE SOLELY BY SALOOMEY
CONSTRUCTION. ANY UNAUTHORIZED USE OF THE INSTRUMENTS OF
SERVICE SHALL BE AT THE OWNER'S SOLE RISK AND WITHOUT LIABILITY
TO HESNOR ENGINEERING ASSOCIATES, PLLC OR SALOOMEY
CONSTRUCTION.CITY OF NORTHAMPTONHAMPSHIRE COUNTYMASSACHUSETTSM-SCI02.A02/14/24PRIOR REVISIONSB02/14/24CONFORMED SETREVISIONS02/24/24100% CD PERMIT SET-P3.10FIRST FLOORVENT PIPINGPLUMBING PLAN1/8" = 1'-0"P3.10
1413ML10KKJHGF10EDCB14984321AA13121176BCDE5FGHJ965M1211874321LSKYLIGHTSKYLIGHTSKYLIGHTSKYLIGHTSKYLIGHTSKYLIGHTKEYED NOTES:2" VENT PIPING FROM BELOW2-1/2" VENT PIPING FROM BELOWTHIS SHEET4" VTR4" VTR4" VTR4" VTR2"2"1-1/4"1-1/4"2"2" VTR2" VTRNOTES:SEE DOMESTIC WATER PLANS FOR ADDITIONAL FIXTURE TAGSTHIS SHEET1-1/4"1-1/4"1-1/2"2"2"1-1/4"1-1/4"2"1-1/4"2"1-1/4"1-1/4"1-1/2"1-1/2"4" VTR2"1-1/4"1-1/4"1-1/2"4" VTR2-1/2"2"2-1/2"2"4" VTR4" VTR2"2"2"
2"1-1/2"
2"2"2"4" VTR1-1/4"2"1-1/4"4" VTR1-1/4"2"2"2"1-1/2"4" VTR2"1-1/4"1-1/4"1-1/4"1-1/4"2"1-1/4"1-1/4"1-1/4"2"1-1/4"4" VTR4" VTR4" VTR1-1/4"
1-1/4"1-1/4"1-1/4"2"1-1/4"2"2"2"2"2"1-1/4"1-1/2"1-1/2"
1-1/4"4" VTR1-1/4"4" VTR1-1/2"1PROSPECT PLACE737 BRIDGE ROADPARCEL 18C-048-001737 BRIDGE ROADJANUARY 9, 2023M-SCI02LBMTSCALE:REVISIONS:No.DATESEAL:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:SCALE:REVISIONS:No.DATEDESCRIPTIONSEAL:2A RIVER STREETADAMS, MA 01220P: (413) 743.9500F: (413) 743.3313www.HESNOR.comTHESE DRAWINGS (INSTRUMENTS OF SERVICE) WERE PREPARED IN A
DESIGN-BUILD FASHION WITH A COLLABORATION BETWEEN HESNOR
ENGINEERING ASSOCIATES, PLLC AND SALOOMEY CONSTRUCTION.
THESE INSTRUMENTS OF SERVICE ARE FOR USE SOLELY BY SALOOMEY
CONSTRUCTION. ANY UNAUTHORIZED USE OF THE INSTRUMENTS OF
SERVICE SHALL BE AT THE OWNER'S SOLE RISK AND WITHOUT LIABILITY
TO HESNOR ENGINEERING ASSOCIATES, PLLC OR SALOOMEY
CONSTRUCTION.CITY OF NORTHAMPTONHAMPSHIRE COUNTYMASSACHUSETTSM-SCI02.A02/14/24PRIOR REVISIONSB02/14/24CONFORMED SETREVISIONS02/24/24100% CD PERMIT SET-P3.20SECOND FLOORVENT PIPINGPLUMBING PLAN1/8" = 1'-0"P3.20
HatchHatchHatchElevatorElevatorDOA2DOA14" VTR4" VTR4" VTR4" VTR4" VTR4" VTR4" VTR4" VTR4" VTR4" VTR4" VTR4" VTR4" VTR4" VTR4" VTR4" VTR2" VTR2" VTR2" VTR4" VTR4" VTR2" VTR2" VTR2" VTROA INTAKE 25-FEET FROMPLUMBING VENTSOA INTAKE 25-FEET FROM
PLUMBING VENTS
PROSPECT PLACE737 BRIDGE ROADPARCEL 18C-048-001737 BRIDGE ROADJANUARY 9, 2023M-SCI02LBMTSCALE:REVISIONS:No.DATESEAL:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:SCALE:REVISIONS:No.DATEDESCRIPTIONSEAL:2A RIVER STREETADAMS, MA 01220P: (413) 743.9500F: (413) 743.3313www.HESNOR.comTHESE DRAWINGS (INSTRUMENTS OF SERVICE) WERE PREPARED IN A
DESIGN-BUILD FASHION WITH A COLLABORATION BETWEEN HESNOR
ENGINEERING ASSOCIATES, PLLC AND SALOOMEY CONSTRUCTION.
THESE INSTRUMENTS OF SERVICE ARE FOR USE SOLELY BY SALOOMEY
CONSTRUCTION. ANY UNAUTHORIZED USE OF THE INSTRUMENTS OF
SERVICE SHALL BE AT THE OWNER'S SOLE RISK AND WITHOUT LIABILITY
TO HESNOR ENGINEERING ASSOCIATES, PLLC OR SALOOMEY
CONSTRUCTION.CITY OF NORTHAMPTONHAMPSHIRE COUNTYMASSACHUSETTSM-SCI02.A02/14/24PRIOR REVISIONSB02/14/24CONFORMED SETREVISIONS02/24/24100% CD PERMIT SET-P4.10ROOF PLUMBINGPLAN1/8" = 1'-0"P4.10
LINK-SEAL MODULAR SEAL DETAILWALL/FOUNDATION- PIPE -SEAL ALL AROUND AS REQ'DTO MAKE WATER-TIGHT- PIPE -BOLTPRESSURE PLATEELASTOMERIC SEALELEMENTTO EXTEND 1" BEYOND EITHEROUTSIDE PIPE DIAMETER. SLEEVE1/2" DIAMETER GREATER THANWITH INSIDE DIAMETER AT LEASTSIDE OF WALL.SCHEDULE 40 STEEL SLEEVENOTE:1.MODULAR SEAL SHALL BE AS MANUF. BY LINK-SEAL OR EQUAL.DETAIL REQ'D AT ALL LOCATIONS WHERE PIPING PENETRATES FOUNDATION WALLINTO THE BUILDING ENVELOPE (CRAWL SPACES, BASEMENT, ETC.)2.LAVATORY INSTALLATION DETAILFLOOR CLEANOUT DETAILBRONZE SCORIATEDCLEANOUT PLUGFLOOR CLEANOUTFLOWCOUNTERSUNKSCREWCLEANOUT COVERAS REQ'DPIPE LENGTHWALL CLEANOUT DETAILWASTE, SOIL, STORM OR VENTSTACK AS APPLICABLEWALLPROVIDE POLISHED S.S.ACCESS COVER IN FINISHED CLEANOUT TEECLEANOUTPLUGCOUNTERSUNKSCREWFLOWWALL CLEANOUTAS REQ'DPIPE LENGTHAREASNOTES:1.LOCATE CLEANOUTS SO THAT C.O. IS ACCESSIBLE AND LOCATED ON CENTER(LEFT/RIGHT & TOP/BOTTOM) WITH THE PIPING COMPONENT SERVED.IDENTIFY ALL CLEANOUTS LOCATIONS ON "AS-BUILT" DRAWINGS.2.NOTES:1.LOCATE CLEANOUTS SO THAT C.O. IS ACCESSIBLE AND LOCATED ON CENTER(LEFT/RIGHT & TOP/BOTTOM) WITH THE PIPING COMPONENT SERVED.IDENTIFY ALL CLEANOUTS LOCATIONS ON "AS-BUILT" DRAWINGS.2.TYPICAL PIPE SUPPORT DETAILSSTEEL OFFSETWALL BRACKETWELDED STEELWALL BRACKETU-BOLTS(TYP.)PROVIDE A SECTION OF HIGHINSULATION AT EACH HANGERPOINT. INSULATION MAY BEHALF ROUND OR FULL ROUNDPIPE (TYP.)INSULATION (TYP.)GALVANIZED IRON SHEET SHIELDSINGLE PIPE RUNSCLEVIS HANGER FORCOMPRESSION STRENGTHAND INSULATION SHALL EXTEND 2" BEYOND GALV. SHIELD EACH WAY.HANGER RODUNISTRUT CHANNELANGLEFOR PIPES UNDER 2" IN SIZE USE1-1/2"x1-1/2"x1/4" ANGLE. ALL PIPES2" & LARGER USE 3"x3"x1/4" ANGLESHEET SHIELDGALVANIZED IRON FLOOR MOUNTED WATER CLOSET DETAILFLOWWASHING MACHINE HOOK-UP DETAILCOUNTERTOPLAVATORYFAUCETESCUTCHEON (TYP.)CHROME PLATEDTYPICAL DRAIN PIPING DETAIL 2" WASTE (MIN.)2" x 1-1/4" (FOR LAVS)2" X 1-1/2" (FOR SINKS)1-1/2" VENT (MIN.)POLISHED CHROME PLATED CASTBRASS ESCUTCHEON WITH SETSCREWWALL1-1/4" (LAVS) 1-1/2" (SINKS)POLISHED CHROME PLATEDP-TRAPPIPE ESCUTCHEON DETAILWALLESCUTCHEON TO BE PROVIDEDIN FINISHED AREASFINISHED AREA1/4" MIN. SPACEALL AROUNDPENETRATION. PROVIDE FIRE BACK STOP MATERIALTHOROUGHLY CAULK & SEALCONTINUOUS INSULATION (WHERE APPLICABLE) THRU SLEEVE. PROVIDE AL. JACKET 2" BEYOND CAULKING ORESCUTCHEON.SEALANT WHERE REQ'D.-PIPE-UNFINISHED AREAAS REQ'D (TYP.)NOTES:1.ALL FIRE STOPPING SHALL BE FURNISHED AND INSTALLED BY THE PC'S INSULATING SUB-CONTRACTOR.SUB-CONTRACTOR SHALL BE CERTIFIED BY FIRE STOPPING MANUFACTURER (HILTI OR EQUAL).DETAIL FOR GENERAL INFORMATION ONLY AND APPLICABLE TO MEMBRANE PENETRATIONS. COORDINATE FIRESTOPPING REQUIREMENTS WITH APPLICABLE UL REQUIREMENT FOR PARTICULAR WALL ASSEMBLY.ONLY COPPER/FERROUS PIPING SHALL PENETRATE FIRE PARTITIONS - REFER TO TYPICAL FIRE-RATED WALLPENETRATION.2.3.PIPING - RATED FIRESTOP THRU GYPSUM WALLSRATED GYPSUMWALL BOARDASSEMBLYSTEEL ORIRON PIPERATED GYPSUMWALL BOARDASSEMBLYSTEEL, IRON ORCOPPER PIPE UPTO 4" TRADE SIZEINSULATED METALLIC PIPINGMETALLIC PIPINGNOTES:1.PIPE MAY BE IN CONTINUOUS POINT CONTACTWITH WALL BOARD (360 DEG.) INSTALL 1/2"CROWN AT POINT CONTACT AREAS.TYPICAL PIPE THRU ROOF DETAILSCALE: N.T.S.SCALE: N.T.S.SCALE: N.T.S.SCALE: N.T.S.FIN. FL.SCALE: N.T.S.FIN. FL.1-1/2" P-TRAPWITH CLEANOUTSCALE: N.T.S.FIN. FL.1-1/2" DRAIN TO STACKDHWS SUPPLY STOP(DCWS SUPPLY STOPBEYOND)1-1/4" VENTTOILET FLANGESCALE: N.T.S.& WAX RINGFIN. FL.WATER CLOSET1/2" DCWS2" VENTSCALE: N.T.S.SCALE: N.T.S.FIBERGLASS OR MINERALWOOL INSULATION UP TO2" THICKSEALANT INSTALLED TO A 5/8" DEPTH WITH A 1/4"CROWN APPLIED TO THE PERIMETER OF THEPIPE. ANNULAR SPACE RANGING FROM POINTCONTACT TO 3/4" MAXIMUMSEALANT. PRODUCT DEPTH:- ONE HOUR RATED ASSEMBLIES, 5/8" DEPTH WITH 1/4" CROWN.- TWO HOUR RATED ASSEMBLIES, 1" DEPTH WITH 1/4" CROWN.- ANNULUS RANGING FROM POINT CONTACT TO 1/4" MAXIMUMDRAWBANDPLUMBING VENT/WH EXHAUST- NOTE 2PRE-MOLDED PIPE BOOTS.S. CLAMP/SEALANT - NOTE 1ROOF SURFACESEALANT - NOTE 1ROOFING ASSEMBLY- NOTE 3BASE FLASHINGSCALE: N.T.S.INSTALL SEALANT AS RECOMMENDED BY THE ROOFINGMANUFACTURER.PC SHALL FURNISH PRE-MOLDED PIPE BOOT FOR INSTALLATION BY THEROOFING CONTRACTOR.BASE FLASHING SHALL BE INSTALLED BY THE ROOFING CONTRACTOR.3.2.1.NOTES:SEAL PENETRATIONS TIGHTEXACT ROUTING OF DOMESTICWATER & D.W.V. PIPING SHALLBE FIELD COORDINATEDEXTERIOR WALL3/4" DCWS PIPING INSTALLEDCONCEALED IN WALLFREEZE-PROOF WALL FAUCET DETAILPROVIDE ISOLATION VALVE INACCESSIBLE LOCATION(ABOVE CEILING OR IN WALL)- PROVIDE ACCESS DOORFOR INSTALLATION BY GC INGYPSUM WALLS/CEILINGSWALL FAUCETVACUUM BREAKERSCALE: N.T.S.SCALE: N.T.S.FLOOR DRAIN DETAILFIN. FL.WALL CAVITYPIPE SLEEVESLOPE FLOOR TO DRAINDCWSNOTES:1.TRAP PRIMER SHALL BE INSTALLED IN 1/2" DCWS PIPING TO PLUMBING FIXTURE IN RESPECTIVE SPACE ORNEAREST LOCATION.2.INSTALL TRAP PRIMER PIPING IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.3.TRAP PRIMER VALVE SHALL BE INSTALLED VERTICALLY AT LEAST 12" ABOVE THE GRID OF THE FLOOR DRAIN.4.ALL REQUIRED TRAP PRIMERS & ASSOCIATED PIPING HAVE NOT BEEN SHOWN ON PLUMBING PLANS.5.INSTALL TRAP PRIMER & PIPING WITHIN WALL OR CEILING CAVITY. PROVIDE ACCESS DOOR AT EACH LOCATIONFOR INSTALLATION BY GC.DCWS TO LOCAL LAV, SINK ORSIMILAR FIXTURE1/2"1/2"1/2"SEE NOTE 5TRAPVENT - SEE PLAN VIEW FORLOCATION OF VENT STACKEXTENDED RIM STRAINERWHERE APPLICABLEPROVIDE DRAFTSTOPPING/FIRE CAULK AS APPLICABLE SCALE: N.T.S.MOP SINK DETAILAND PAILHOOKSPOUT WITH HOSE ENDSERVICE FAUCET36"TRAPSPOUT BRACE(WHERE APPLICABLE)WALLMOP SINKFIN. FL.STRAINERSEE PLAN VIEWFOR CONTINUATIONVENTSEE PLAN FOR LOCATIONOF VENT STACKPIPE SLEEVE (TYP.)NOTES:1.MODIFY DETAIL TO SUIT MOP SINKS WITH TRAPINSTALLED ABOVE FINISHED FLOOR WHERE APPLICABLE.2.PROVIDE ALL ACCESSORIES INDICATED.S.S. SPLASH GUARD (2 SIDES)WITH VACUUMBREAKERHOSE BRACKETMOP RACKHEAVY DUTY, 5/8"FLEXIBLE RUBBER HOSESCALE: N.T.S.FIN FL.1.SEE PLUMBING PLANS FOR CONTINUATION OF DHWS AND WASTE PIPING.NOTES:1/2" DHWSDISHWASHER2.CONNECT DHWS AND WASTE PIPING TO HOSES SUPPLIED W/ DISHWASHER.3. HOSE CONNECTION TO WASTE PIPING SHALL BE 16" ABOVE FIN. FL. MAX.4.PROVIDE APPROVED BACKFLOW PREVENTER IN POTABLE WATER PIPING IFNOT INTEGRAL TO APPLIANCE.5. ALL PIPING SHALL BE INSTALLED CONCEALED IN BASE CABINET, WALL, ETC.SINKTHRU FLOOROR WALL ASAPPLICABLEBALL VALVE& STRAINERMINI WATER HAMMERARRESTOR WATTS MODELNO. O5H OR EQUALCONNECT TODISHWASHER SUPPLYHOSE.UNDER-COUNTERDISHWASHER-PC TO MAKE ALL SUPPLY/DRAIN CONNECTIONSPUMPEDWASTEHOSEVENTDISHWASHER DETAILSCALE: N.T.S.P-TRAP W/CLEANOUT PLUGDHWSFIN FL.BOX-OUT AND FRAMING BY GCDCWS2" WASTE
2" WASTE1-1/2" VENTSEE PLAN FOR CONTINUATIONSEE PLAN FOR CONTINUATIONFIN. WALLALL PIPING TO BE INSTALLEDCONCEALED WITHIN WALLWATER-TITE DU-ALL, MODEL No. W2700HA WASHINGMACHINE SHUT-OFF VALVE ASSEMBLY W/ WATERHAMMER ARRESTORS OR EQUAL- NOTE 112" x 12" ACCESS PANELFURNISHED BY PC FORINSTALLATION BY GCAPPROX. 60" AFF
MIN 36"STANDPIPE1.COORDINATE EXACT MODEL No. WITH PIPECONNECTION TYPE.2.FIELD VERIFY EXACT MOUNTING HEIGHTWITH APPROVED WASHING MACHINESUBMITTAL.NOTES:WATER HAMMERARRESTOR(TYP.)- NOTE 2
PROSPECT PLACE737 BRIDGE ROADPARCEL 18C-048-001737 BRIDGE ROADJANUARY 9, 2023M-SCI02LBMTSCALE:REVISIONS:No.DATESEAL:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:SCALE:REVISIONS:No.DATEDESCRIPTIONSEAL:2A RIVER STREETADAMS, MA 01220P: (413) 743.9500F: (413) 743.3313www.HESNOR.comTHESE DRAWINGS (INSTRUMENTS OF SERVICE) WERE PREPARED IN A
DESIGN-BUILD FASHION WITH A COLLABORATION BETWEEN HESNOR
ENGINEERING ASSOCIATES, PLLC AND SALOOMEY CONSTRUCTION.
THESE INSTRUMENTS OF SERVICE ARE FOR USE SOLELY BY SALOOMEY
CONSTRUCTION. ANY UNAUTHORIZED USE OF THE INSTRUMENTS OF
SERVICE SHALL BE AT THE OWNER'S SOLE RISK AND WITHOUT LIABILITY
TO HESNOR ENGINEERING ASSOCIATES, PLLC OR SALOOMEY
CONSTRUCTION.CITY OF NORTHAMPTONHAMPSHIRE COUNTYMASSACHUSETTSM-SCI02.A02/14/24PRIOR REVISIONSB02/14/24CONFORMED SETREVISIONS02/24/24100% CD PERMIT SET-P5.01PLUMBINGDETAILSN.T.S.P5.01
WATER SERVICE ENTRANCE DETAILSCALE: N.T.S.NOTES:1.WATER METER SHALL BE PROVIDED IN ACCORDANCEWITH NORTHAMPTON WATER DEPARTMENTREQUIREMENTS.2.4" PRESSURE REDUCING VALVE, WATTS MODEL No. XXXOR EQUAL.3.4" REDUCED PRESSURE ZONE ASSEMBLY, WATTS MODELNo. XXX WITH AIR GAP & ELBOW OR EQUAL.FIN. FL.DRAIN4" DCWS4" BRONZE STRAINERSEE NOTE 14"Ø4"Ø
FROM STREETDCWS TOBUILDINGPRVMECHANICAL ROOM3/4" BALL VALVE W/HOSE THREAD,VACUUM BREAKER &CAPBALL VALVE (TYP.)3/4" GALVANIZED STANCHION(TYPICAL)WATER METER- NOTE 14" LEAD-FREEPRESSUREREDUCING VALVEEXTERIOR WALLLINK SEAL- SEE DETAIL ONSHEET P-501SLEEVEELEVATOR SUMP PUMP DETAILBALL VALVELEGEND:UNIONCHECK VALVEBY E.C.TYPE RECEPTACLE 120 VOLT G.F.I.ELEVATORSHAFTSUMP PUMPTO OIL SEPARATORANNULAR SPACE AND GROUTSTEEL WALL SLEEVE, PACK SP-XC.O.RELAY2" MIN.PUMP ON LEVELPUMP OFF LEVELHIGH WATER LEVELABOVE WATER LINEPIGGYBACK PLUGSIMPLEX ALARM PANELSCALE: N.T.S.OIL SEPARATOR DETAILOIL SEPARATOR2" VENTPLAN VIEWSIDE VIEWINTEGRAL FLOWCONTROL FITTINGFIN. FL.OIL STORAGETANKBULKHEAD3" WASTE TOBUILDING DRAIN2" VENT (TYP. OF 3)- SEE PLANS FORCONTINUATION OF PIPING3" WASTE PIPING TO BUILDING DRAIN- SEE PLANS FOR CONTINUATION OF PIPING3" WASTE PIPING FROM SUMPPUMP- SEE PLANS FORCONTINUATION OF PIPING2"2"3"
3"COVER2"SEE FLOOR PLANS THISSHEET FOR CONTINUATION OFPIPINGOIL SEPARATOR/STORAGETANK6" LAYERS OF SANDPLACED AND COMPACTED95% MIN.POWER BY ECALARM WIRING TOOIL SENSOR BY ECPROVIDE DEDICATEDINLET & OUTLET VENTSOIL HIGH LEVEL ALARM PANELWITH AUDIBLE ALARM- LOCATE IN ROOM B204ASCALE: N.T.S.IN-LINE PUMP DETAIL SPRING HANGERPRESSURE GAGE1/2"PUMP1. SUPPORT PUMP FROM PIPING ONLY. DO NOT SUPPORT PUMP FROM MOTOR. NOTES:CBVTHREADED RODPROVIDE UNION IF PUMPNOT EQUIPPED WITHFLANGESPROVIDE TWIN-SPHERENEOPRENE FLEXIBLECONNECTIONSSCALE: N.T.S.ENLARGED MECHANICAL ROOM PLANSCALE: 1/4" = 1'-0"HEAT PUMP WATER HEATER ONE-LINE DIAGRAMSCALE: N.T.S.MASTERCONTROLPANELHPWH1AHPWH1BTANK THERMOSTAT (TYP.)PIPE T&P TO FLOORDRAIN (TYP.)DOMESTIC HOT WATER RETURN PIPING (DHWR)DOMESTIC COLD WATER SUPPLY PIPING (DCWS)DOMESTIC HOT WATER SUPPLY PIPING (DHWS)SOURCEWATER OUTSOURCEWATER INTMV1HPWH1ADOMESTIC WATER SERVICEENTRANCE EQUIPMENT- SEE DETAIL THIS SHEETETP1DWST2DWST1RCP1ST1HPWH1BDWST1ADWST1BST1NOTES:1.EXACT LOCATION & QUANTITY OF VACUUM BREAKERS SHALL BE PERMA PLUMBING CODE.PIPING SHALL BE INSTALLED IN STRICT ACCORDANCE WITHMANUFACTURER'S GUIDELINES/INSTRUCTIONS OF APPROVED TMV.2.BALL VALVELEGEND:THERMOMETERUNIONCHECK VALVECIRCUIT BALANCINGVALVEVACUUM BREAKERCIRCULATING PUMPPRESSURE RELIEF VALVETEMPERATURE & DRAINAQAQUASTATSTRAINERTXTANK OR LINE TEMPERATURE CONTROL4"4"T2T2T14"FIN. FL.DRAIN VALVE (TYP.)ETP14"HEAT PUMP LOOPPIPING BY MCCONDENSATE PIPING TOSPILL AT FLOOR DRAIN(TYP.)4"4"FLUSH VALVE(TYP.)CONTROLWIRINGDHWRAQRECIRCULATINGPUMPRCP1DHWS TOBUILDINGHEAT TRAP(MIN. 24")4"4"
4"TMV1NOTE 2FD2FD2FD1SHEET KEYED NOTESPROVIDE 1/2" DCWS FOR TRAP PRIMER AT FLOOR DRAIN. CONNECT TOCLOSET PLUMBING FIXTURE- ROUTE TRAP PRIMER PIPING BELOW FIN FL- SIOUX CHIEF, MODEL No. 695 OR EQUALSEE HEAT PUMP WATER HEATER ONE-LINE DIAGRAM THIS SHEET FORCONTINUATION OF PIPINGSEQUENCE OF OPERATIONS:A. SLAVE SEQUENCE OF OPERATION:1.POWER IS TURNED ON2.SYSTEM IS PUT INTO CYCLE (START IS PRESSED)3.COMPRESSOR TIME DELAY COUNTS DOWN4.TANK TEMP. PROBE SEES CUT-IN TEMP., TURNS ON PUMP(S)5.WATER FLOW IS VERIFIED, LIQUID LINE SOLENOID VALVE OPENS, COMPRESSOR TURNS ON, FANS TURN ON (ASHP)6.TANK TEMP. PROBE SEES CUT-OUT TEMP., CLOSES LIQUID LINE SOLENOID VALVE, COMPRESSOR PUMPS DOWN7.PUMP(S) AND FANS (ASHP) TURN OFFB. ALARMS:1.LOW PRESSURE (10 PSIG)2.HIGH PRESSURE (410 PSIG)3.HEATED WATER FLOW4.DEFROST5.EVAPORATOR FLOW (WSHP) / BLOWER FAULT (ASHP)6.MOTOR PROTECTION (ON MODELS EQUIPPED WITH A MOTOR PROTECTION MODULE)7.PHASE PROTECTION (ON MODELS EQUIPPED WITH A PHASE PROTECTION MODULE)C. HEAT PUMP MASTER/SLAVE SEQUENCE OF OPERATIONS:1.HOT WATER STORAGE TANK:a. MASTER CONTROL WILL MONITOR THE HOT WATER STORAGE TANK TEMPERATURE AT A CERTAIN VERTICAL DISTANCE FROM THE TANK OUTLET.b. WHEN TANK TEMPERATURE REACHES 10°F (ADJUSTABLE VARIABLE BASED UPON TANK CHARACTERISTICS AND MEASUREMENT LOCATION) BELOW TANKTEMPERATURE SET POINT (DIFFERENCE WILL BE “STORAGE DELTA SET POINT”), THE MASTER WILL CALL THE FIRST UNIT TO RUN.c. IF AFTER 3 MINUTES THE TANK TEMPERATURE DOES NOT INCREASE, ANOTHER UNIT WILL BE CALLED TO RUN, THE MASTER WILL CONTINUE TO CALL UNITSIN ORDER UNTIL THE TANK TEMPERATURE DOES START TO INCREASE BY 1°F.d. THE MASTER WILL CONTINUE TO CHECK TANK TEMPERATURE EVERY 2 MINUTES TO ENSURE IT IS STILL RISING AND WILL CALL ADDITIONAL UNITS ASREQUIRED TO MAINTAIN AN INCREASE IN TANK TEMPERATURE.2.HEAT PUMPS:a. MASTER CONTROL WILL DETERMINE A RUN ORDER FOR THE HEAT PUMPS TO BE CALLED BASED UPON COMPRESSOR RUN TIME COMPARISONS, ALARMSTATUS, AND UNIT NUMBER.b. IF A CALLED SLAVE UNIT SHOWS AN ALARM CONDITION THE MASTER CONTROL WILL SELECT THE NEXT UNIT IN THE RUN ORDER. IN AN INSTANCE WHERETHE COMPRESSOR RUN TIME HOURS ARE EQUAL BETWEEN TWO UNITS THE UNIT NUMBER WILL DETERMINE THE RUN ORDER.3.EVAPORATOR COILS:a. IF THE EVAPORATOR TEMPERATURE IS EQUAL TO OR BELOW 45°F, THE HEATING ELEMENTS WILL BE ENERGIZED WARMING THE AIR FLOWING ACROSS THECOILS, MAINTAINING THE 45° +/- THRESHOLD ALLOWING FOR THE HP TO CONTINUE TO RUN AND HEAT WATER AS OPPOSED TO SHUTTING DOWN AND GOINGINTO DEFROST.b. ONCE THE EVAPORATOR TEMPERATURE RISES AND REACHES 52°F THE HEATING ELEMENTS WILL BE DE-ENERGIZED. THE MASTER CONTROL WILLCONTINUE NORMAL OPERATION AND CALL ON INDIVIDUAL UNITS REGARDLESS OF WHETHER THE EVAPORATOR TEMPERATURE IS BELOW OR ABOVE 45°F.4.PUMPS:a. THE PUMPS SERVICING THE BUILDING LOOP SHOULD BE CONSTANTLY CIRCULATING. THE PUMPS CIRCULATING WATER TO/FROM OUR UNITS AND STORAGESHOULD BE SET UP TO OPERATE ONLY WHEN OUR UNITS RECEIVE A CALL.b. ONCE THE TANK TEMPERATURE SETPOINT HAS BEEN REACHED THE MASTER CONTROL PANEL WILL SEND THE SIGNAL TO ALL UNITS AT THE SAME TIME TOSHUT DOWN. EACH RUNNING UNIT WILL SHUT THE SOLENOID VALVE AND ENTER A PUMP DOWN CYCLE AND THEN SHUT OFF THE COMPRESSOR. ONCE THERUNNING UNITS RECEIVE THE CALL TO SHUT DOWN, THEY WILL CONTINUE TO RUN THE CONDENSER PUMPS FOR 2 MINUTES.PROSPECT PLACE737 BRIDGE ROADPARCEL 18C-048-001737 BRIDGE ROADJANUARY 9, 2023M-SCI02LBMTSCALE:REVISIONS:No.DATESEAL:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:SCALE:REVISIONS:No.DATEDESCRIPTIONSEAL:2A RIVER STREETADAMS, MA 01220P: (413) 743.9500F: (413) 743.3313www.HESNOR.comTHESE DRAWINGS (INSTRUMENTS OF SERVICE) WERE PREPARED IN A
DESIGN-BUILD FASHION WITH A COLLABORATION BETWEEN HESNOR
ENGINEERING ASSOCIATES, PLLC AND SALOOMEY CONSTRUCTION.
THESE INSTRUMENTS OF SERVICE ARE FOR USE SOLELY BY SALOOMEY
CONSTRUCTION. ANY UNAUTHORIZED USE OF THE INSTRUMENTS OF
SERVICE SHALL BE AT THE OWNER'S SOLE RISK AND WITHOUT LIABILITY
TO HESNOR ENGINEERING ASSOCIATES, PLLC OR SALOOMEY
CONSTRUCTION.CITY OF NORTHAMPTONHAMPSHIRE COUNTYMASSACHUSETTSM-SCI02.A02/14/24PRIOR REVISIONSB02/14/24CONFORMED SETREVISIONS02/24/24100% CD PERMIT SET-P5.02PLUMBINGDETAILSAS SHOWNP5.02
PLUMBING FIXTURE SCHEDULETAGREMARKSMANUF.MODEL No.FINISHKS1STAINLESSSTEELELKAYSINK (ADA):- 25"x22", 22 GAUGE STAINLESS STEEL TOP MOUNT SINK W/ REAR RIGHT DRAIN- SINGLE BOWL, (3) HOLES, 5-3/8" DEPTH- DECK MOUNTED, SINGLE HANDLE GOOSENECK SPOUT, 1.5GPM, ELKAY MODEL No. LK100CR WITH DECK PLATE.- 1/2" CHROME SUPPLY WITH KEY STOP AND CAST BRASS CHROME PLATED ESCUTCHEON- 1-1/2" CAST BRASS CHROME PLATED "P" TRAP WITH CLEANOUT PLUG & SINK STRAINER W/ TAILPIECEGE12522LV1765AA104VITREOUSCHINAAMERICANSTANDARDWATER CLOSET (ADA):- TANK TYPE, FLOOR MOUNT, BOTTOM OUTLET, ELONGATED BOWL WITH OPEN FRONT SEAT- 1.28 GALLONS PER FLUSH- POWER WASH RIM- PROVIDE W/ WAX RING & FLANGEADJUSTABLE FLOOR DRAIN:- PROVIDE WITH 6" Ø ROUND FLOOR DRAIN- EPOXY COATED CAST-IRON FLOOR DRAIN WITH ANCHOR FLANGE, CLAMPING COLLAR- PROVIDE FOR CONNECTION TO 3" CAST IRON PIPING- PROVIDE P-TRAP W/ 1/2 " TAP FOR TRAP PRIMER CONNECTION & FLOW ACTIVATED TRAP SEALPRIMER WITH INTEGRAL VACUUM BREAKERREMARKSSANITARY WASTE PIPING SPECIALTIES SCHEDULESP-1TAGSUMP PUMP SCHEDULEGPMHEAD (FT)REMARKSHPMANUF.MODEL No.N15352ZOELLER20ELECTRIC120/1/601/2SYSTEMSEE NOTESNOTES:1.PROVIDE WITH PIGGYBACK VARIABLE LEVEL FLOAT SWITCH.2.REFER TO SUMP PUMP DETAIL FOR TYPICAL INSTALLATION.3.PROVIDE WITH SINGLE-PHASE SIMPLEX PLUG-IN CONTROL PANEL WITH NEMA 4X ENCLOSURE,RECEPTACLE FOR USE WITH PIGGYBACK PUMP SWITCH, ALARM HORN & TERMINAL STRIP.MODEL No.MANUF.TAGFD-100-A-7WATTSHIGHLANDTANKFD1OS1ADJUSTABLE FLOOR DRAIN:- PROVIDE WITH 6" Ø SQUARE FLOOR DRAIN W/ HINGED GRATE- EPOXY COATED CAST-IRON FLOOR DRAIN WITH ANCHOR FLANGE, CLAMPING COLLAR- PROVIDE FOR CONNECTION TO 4" CAST IRON PIPING- PROVIDE P-TRAP W/ 1/2 " TAP FOR TRAP PRIMER CONNECTION & FLOW ACTIVATED TRAP SEALPRIMER WITH INTEGRAL VACUUM BREAKER30000-6T-ZJOSAMFD2SH1TAGTYPEPUMP SCHEDULEFLUIDGPMHEADMAX.SERVICE(FT.)RPMELECTRICHPSYSTEMREMARKSMANUF.MODEL No.ALL BRONZE OR STAINLESS STEEL CIRCULATING PUMP SUITABLE FOR DOMESTIC HOT WATER SERVICE1.RCP-1GRUNDFOSMAGNA3 32-120FS. STEELDHWRWATER3020--120/1/60NOTES 1 & 2PROVIDE WITH TEMPERATURE SENSOR2.XST-6232-TR.75FIBERGLASSCOMFORTDESIGNSSHOWER (ADA):-SINGLE PIECE, ROLL-IN MAAB CODE COMPLIANT SHOWER W/ CENTER DRAIN, 3/4" THRESHOLD & CENTER DRAIN-PROVIDE W/ GRAB BARS, SOAP DISH, SHOWER CURTAIN W/ S.S. HOOKS, CURTAIN ROD & FOLDING SEAT.-PROVIDE W/ HAND SHOWER SYSTEM, SYMMONS MODEL No. S-9603-PLR-1.5 W/ TEMPROL PRESSURE BALANCINGVALVE, 36" SLIDE BAR, IN-LINE VACUUM BREAKER, 60" HOSE, ADA HAND SHOWER & 1.5 GPM FLOW RESTRICTOR.MOI-50-SOSTEEL OIL SEPARATOR:- W/ INTEGRAL SIDE OIL STORAGE TANK, THREADED CONNECTIONS, SEDIMENT BUCKET,CHECK VALVE & FLOW CONTROL FITTING- 50 GPM W/ 100 GAL STORAGE TANK AND ADJUSTABLE OIL SKIMMER- CARBON STEEL DECK PLATE COVER, HIGH OIL LEVEL SENSOR & HTAP-1 ALARM PANELWC1NOTES:JR. SMITH5609QTWALL FAUCET:- EXPOSED, NON-FREEZE ANTI-SIPHON, AUTOMATIC DRAINING, WALL FAUCET WITH INTEGRAL BACKFLOW PREVENTER, 3/4"THREADED INLET, FREE-FLOATING COMPRESSION CLOSURE VALVE, 3/4" MALE ANGLED HOSE CONNECTION- COORDINATE REQ'D PIPE LENGTH WITH WALL THICKNESS AT EACH LOCATIONEXTERIORCHROME-SWANSTONE-LAVATORY (ADA):-SOLID SURFACE VANITY TOP BY GC. PC SHALL PROVIDE THE FOLLOWING:-PROVIDE (2 HOLES MOUNTED FAUCET, LEVER HANDLE, 1.2 GPM, AMERICAN STANDARD MODEL No. 7075.200-1/2" CHROME SUPPLY W/ KEY STOP & CAST BRASS CHROME PLATED ESCUTCHEON-1-1/4" x 1-1/2" CAST BRASS CHROME PLATED P-TRAP W/ CLEANOUT PLUG & POP-UP DRAINHB1ET-P1TAGMOUNTINGPOTABLE WATER EXPANSION TANK SCHEDULE/TANK VOLUMEREMARKSMANUF.MODEL No.WHV-165FLOOR17.7/44.0FLEXCONWORKING PRESS150(GAL.)ACCEPTABLE MANUFACTURERS: LOCHINVAR, RINNAI, VIESSMANN OR EQUALHPWH-1TAGMODEL No.C185WTYPECOMPRESSORSCROLLHEAT PUMP WATER HEATER SCHEDULERECOVERYCONDENSER18.5146SYSTEM30(GPM)208/3/60REMARKSEWT (°F)(GPH)SOURCEAMPSELECTRIC78NOTES:1.PROVIDE WITH CONDENSATE TRAP & NEUTRALIZER KIT, HIGH LIMIT W/ MANUAL RESET, COMBINATION PRESSURE/TEMPERATURE GAUGE,FLOW SWITCH, TEMPERATURE & PRESSURE RELIEF VALVE & DIRECT VENT KIT.MANUF.NYLESEE NOTESSINGLE PASSHPWH-2SCROLLSEE NOTESSIZEDIA (IN.)HEIGHT (IN.)21"36.2"208/3/60DIGITALLY CONTROLLED MIXING VALVE:- W/ 2" INLET ANGLED CHECK STOPS, 2" OUTLET AND INTEGRAL RTD SENSOR- 2" NPT INLETS, 2" NPT OUTLET- AUTOMATIC HOT/COLD WATER SHUT-OFF UPON COLD/HOT WATER INLET SUPPLY FAILURE- PROGRAMMABLE SET POINT RANGE BETWEEN 65° AND 180°F, CONTROL WITHIN ±2°F FROM SET POINT- UL LISTED CONTROL BOX AND 120V PLUG IN POWER SUPPLY WITH 6' CORD- STANDARD CONTROL BOX- SELF BALANCING, SELF CLEANINGPNV-200-LFACCEPTANCEMAX. TAGREMARKSMANUF.MODEL No.THERMOSTATIC MIXING VALVE SCHEDULEFINISHLEONARDBRASSTMV1MANUFACTURERS: LEONARD, BRADLEY, TACO OR EQUALNOTES:1. PROVIDE MANUFACTURER'S "START-UP"/INSPECTION OF THERMOSTATIC MIXING VALVE INSTALLATIONS. COORDINATE SETTING WITHMA PLUMBING CODE.PIPING INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH MANUFACTURER'S GUIDELINES/INSTRUCTIONS OF APPROVED TMV.2. C185W18.51463078NYLESINGLE PASSWATERDIMENSIONS49" x 31-1/4" x 38-1/4"(L x W x H)49" x 31-1/4" x 38-1/4"EVAP.30(GPM)30WATERCAPACITY121.6(MBH)121.6LV2PUBLIC LAVATORY (ADA):-SOLID SURFACE VANITY TOP BY GC. PC SHALL PROVIDE THE FOLLOWING:-PROVIDE (2 HOLES MOUNTED FAUCET, LEVER HANDLE, 0.5 GPM AERATOR, AMERICAN STANDARD MODEL No. 7075.200-1/2" CHROME SUPPLY W/ KEY STOP & CAST BRASS CHROME PLATED ESCUTCHEON-1-1/4" x 1-1/2" CAST BRASS CHROME PLATED P-TRAP W/ CLEANOUT PLUG & POP-UP DRAINSWANSTONE--L-BAR-1NOTES:STORAGE TANK SHALL BE EQUIPPED WITH BAFFLE CHAMBER DESIGN TO ENSURE THAT 80% OF STORED VOLUME OF WATERMAY BE DRAWN FROM THE TANK WITHOUT A DROP IN THE PRE-SET OUTLET TEMPERATURE.STORAGE TANK SHALL BE PROVIDED WITH INLETS/OUTLETS, MAN WAY AND TRIP RELIEF VALVE.1.2.DWST-1ATAGMODEL No.WHSSG-COMPRESSORXPOTABLE HOT WATER STORAGE TANK SCHEDULEVERTICALSEE NOTESX(PSI)MANUF.NYLE318REMARKSGLASS LINEDXXASME0318HNADWST-1BNWHSSG-XSEE NOTESXNYLE432XX0432HNACAPACITY(GAL)PRESSUREINSULATEDW/ JACKETTAGMODEL No.GALELEMENTELECTRIC WATER STORAGE TANK SCHEDULEELECTRICREMARKSSYSTEMNOTES:1.PROVIDE WITH WIRING FOR SIMULTANEOUS OPERATIONMANUF.RECOVERYAMPS∆T(°F)(GPH)WATTAGEST-1NWHSSG-6000/6000SEE NOTES240/3/60NYLE1196143.3/25.00119MNA80PROSPECT PLACE737 BRIDGE ROADPARCEL 18C-048-001737 BRIDGE ROADJANUARY 9, 2023M-SCI02LBMTSCALE:REVISIONS:No.DATESEAL:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:DATE:DRAWN BY:CHECKED BY:PROJECT No:FILE:SCALE:REVISIONS:No.DATEDESCRIPTIONSEAL:2A RIVER STREETADAMS, MA 01220P: (413) 743.9500F: (413) 743.3313www.HESNOR.comTHESE DRAWINGS (INSTRUMENTS OF SERVICE) WERE PREPARED IN A
DESIGN-BUILD FASHION WITH A COLLABORATION BETWEEN HESNOR
ENGINEERING ASSOCIATES, PLLC AND SALOOMEY CONSTRUCTION.
THESE INSTRUMENTS OF SERVICE ARE FOR USE SOLELY BY SALOOMEY
CONSTRUCTION. ANY UNAUTHORIZED USE OF THE INSTRUMENTS OF
SERVICE SHALL BE AT THE OWNER'S SOLE RISK AND WITHOUT LIABILITY
TO HESNOR ENGINEERING ASSOCIATES, PLLC OR SALOOMEY
CONSTRUCTION.CITY OF NORTHAMPTONHAMPSHIRE COUNTYMASSACHUSETTSM-SCI02.A02/14/24PRIOR REVISIONSB02/14/24CONFORMED SETREVISIONS02/24/24100% CD PERMIT SET-P7.01PLUMBINGSCHEDULESN.T.S.P7.01