Loading...
IECCUA15_5__0178_Matt C 5 Pomeroy Ter. Unit 5 Nhton 3rd Fl LEFT_REPORT2015 IECC Building UA Compliance Property Matthew Campagnari 5 Pomeroy Ter Unit 5 Northampton, MA 01060 Weather:Chicopee, MA Shaw Hotel 3rd floor Left Unit 5 0073-0173-C6R1_Campagnari_Con struction_LLC_5_Pomeroy_Ter_Un Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Campagnari Construction LLC HERS Confirmed 2019-08-09 Rating No:0073_0178 Rater ID:8776762 REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. Elements Insulation Levels 2015 IECC As Designed Shell UA Check Ceilings:23.1 20.7 Above-Grade Walls:17.8 19.8 Windows and Doors:25.5 20.1 Overall UA (Design must be equal or lower):66.3 60.5 Mandatory Requirements Shell UA Check PASSES Duct Insulation R-Value Check (per Section 403.3.1)PASSES Window U-Value and SHGC Check (per Section 402.5)PASSES Home Infiltration (Section 402.4.1.2)PASSES Duct Testing (Section 403.3.3)PASSES Mechanical Ventilation (Section 403.6)PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1)PASSES Mandatory Requirements Check Box (2015 IECC)PASSES This home MEETS the overall thermal performance requirements and verifications of the International Energy Conservation Code based on a climate zone of 5A. (Section 402, International Energy Conservation Code, 2015 edition.) In fact, this home surpasses the requirements by 8.8%. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 14 August 2019 HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2015 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 5 Pomeroy Ter Unit 5, Northampton, MA by Campagnari Construction LLC exceeds the minimum requirements for the 2015 International Energy Conservation Code The 2015 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Building Features Ceiling Flat R-49.0 Duct Uninsulated Sealed Attic:NA Duct Leakage to Outside:11.00 CFM @ 25 Pascals Vaulted Ceiling R-49.0 Total Duct Leakage:32.00 CFM @ 25 Pascals Above Grade Walls R-21.0 Infiltration:Htg: 342 Clg: 342 CFM50 Foundation Walls NA Window U-Value: 0.270, SHGC: 0.330 Exposed Floor NA Air-Source HP Electric, Htg: 8.5 HSPF. Clg: 14.0 SEER. Slab None Water Heating Heat pump, Electric, 3.53 EF, 50.0 Gal. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 14 August 2019 2015 IECC Certificate 5 Pomeroy Ter Unit 5, Northampton, MA 01060 Building Envelope Insulation Ceiling R-49.0 Above Grade Walls R-21.0 Foundation Walls NA Exposed Floor NA Slab None Infiltration Htg: 342 Clg: 342 CFM50 Duct Uninsulated Total Duct Leakage 32.00 CFM @ 25 Pascals Window Data U-Factor SHGC Window 0.270 0.330 Mechanical Equipment ASHP: Electric, Htg: 8.5 HSPF. Clg: 14.0 SEER. DHW: Heat pump, Electric, 3.53 EF, 50.0 Gal. Builder or Design Professional Signature REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 Home Energy Rating Certificate HERS Index: 62 REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. General Information Conditioned Area 882 sq. ft.House Type Apartment, end unit Mechanical Systems Features Air-source heat pump:Electric, Htg: 8.5 HSPF. Clg: 14.0 SEER. Building Shell Features Ceiling Flat R-49.0 Slab None Lights and Appliance Features Interior Fluor Lighting (%)0.0 Range/Oven Fuel Electric TITLE Estimated Annual Energy Cost Use MMBtu Cost Percent Heating 6.1 $261 27% Conditioned Volume 6936 cubic ft.Foundation Apartment above cond. space Water Heating:Heat pump, Electric, 3.53 EF, 50.0 Gal. Sealed Attic NA Exposed Floor NA Interior LED Lighting (%)100.0 Clothes Dryer Fuel Electric Company Cooling 1.1 $46 5% Bedrooms 1 Duct Leakage to Outside 11.00 CFM25. Vaulted Ceiling R-49.0 Window Type U-Value: 0.270, SHGC: 0.330 Refrigerator (kWh/yr)750 Clothes Dryer CEF 2.62 Address Hot Water 2.2 $95 10% Ventilation System Exhaust Only: 42 cfm, 10.0 watts. Above Grade Walls R-21.0 Infiltration Rate Htg: 342 Clg: 342 CFM50 Dishwasher Energy Factor 0.46 Ceiling Fan (cfm/Watt)0.00 City, State, Zip Lights/Appliances 12.5 $536 55% Programmable Thermostat Heat=Yes; Cool=Yes Foundation Walls NA Method Blower door Phone # Photovoltaics -0.0 $-0 -0% Fax # Service Charges $33 3% Total 21.8 $971 100% Property HERS Matthew Campagnari Rating Type:Confirmed Certified Energy Rater:Paul J. DellaTorre 5 Pomeroy Ter Unit 5 Rating Date:2019-08-09 Rating Number:0073_0178 Northampton, MA 01060 Registry ID:462943927 Criteria This home meets or exceeds the minimum criteria for the following: This home has been inspected and performance tested in accordance with Chapter 3 of the RESNET standards. TITLE Company Address City, State, Zip Phone # 5 Pomeroy Ter Unit 5 Northampton, MA 01060 Rater: Paul J. DellaTorre Registry ID: 462943927Annual Estimates*: Elec(kWh): 6401 C02 emissions(Tons): 4 Energy Savings ($)**: 1002 *Based on standard operating conditions **Based on U.S. DOE designation of a HERS Index of 130 as the 'Typical Existing Home' 62