Loading...
14 lasell 1 MAY 24 A1 DETTHESE DOCUMENTS ARE THE PROPERTY OF JEFFREY SCOTT PENN, ARCHITECT, TEL. 413-531-1868, AND MAY ONLY BE USED FOR THE SCOPE AND DURATION OF THIS PROJECT OFD1 CANOPY TUBES SCALE: 1/2" = 1'-0" REVISIONS: RENOVATIONS NORTHAMPTON MA 14-16 LASELL STREET SCALE 0 1'2'3'4'5'10'20' 3 12 9'-2 1/4" 9'-3" 7" 8" 19'-8 1/4" (8 3/4) 12 TYPICAL SECTION EXT. CHANNEL WITH CANOPY SUPPORT PREFAB 8"x8" LINTEL EXISTING WOOD BEAM ALL DIMENSIONS VIF TIE RODS TIE RODS TIE RODS 2'-10 1/4" (1'-9")GRADE TIE RODS NEW BEARING BEAM 3'-3 3/4" 5 1/2" WALL RAFTERS PARALLEL TO BUILDING TUBE AT CANOPY - HSS 6x2x5/16 3 12FLASHING PLATE MIN. 1" ABOVE 1.5"x4.5"x1/4" RAFTER BEARING PLATES WELDED VERTICAL @ 12"oc 6 HOLES EACH 5/16" - RAFTERS MAY BE NOTCHED AT ANGLE TO BEAR - DRILL FOR 5 SIMPSON JOIST HANGER SCREWS END/JUNCTION PLATE VERTICAL TUBE/CHANNEL ANGLED TUBES (1'-4 1/2") THIS TIE ROD NEAR THE CANOPY MAY BE WELDED TO THE INTERIOR FACE AND COUPLED WITH INTERIOR JOIST TIES ANGLED TUBES AT CANOPY -TU 2.5x1.5x1/4 TOPS OF 2x8 RAFTERS MAY BE TAPERED FOR SHEATHING - 5/8" CDX MIN.. FLASHING PLATE TUBE AT CANOPY - HSS 6x2x5/16 WELD FLASHING TO TUBE MIN. 1" ABOVE EXISTING FLASHING - APPROX. 1/4" GAP FOR COUNTER FLASHING EXISTING FLASHING HEIGHT EXISTING FLASHING HEIGHT - CUT AROUND TUBE AND COUNTER FLASH ALL NEW INSTALLATIONS WELD ALL JOINTS ALL AROUND WITH 100% BUTT OR 1/4" FILLET - GRIND SMOOTH BEFORE GALVANIZING FASCIA/LADDER ATTACHED TO END RAFTER TIE ROD WELDED TO INTERIOR OF TUBE; MEET PRE DRILLED HOLES VIF AND COUPLE TO ATTACHMENT DATE: 1 MAY 2024 1'-6 3/16" 2 9/16" THIS PROPOSAL SETS TOP OF ROOF/CANOPY ROOFING AT APPROX. 7" BELOW EXISTING FLASHING LINE 7'-9 1/2"