Loading...
CS Beam D CalcCS Beam 2021.5.0.8 kmBeamEngine 2018.9.0.1 Materials Database 1587 D'Amour 272 Old Wilson Rd 7-21-22 1:24pm 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Member Data Description: Beam d Member Type: Beam Application: Floor 2nd floor stairwell beam Top Lateral Bracing: Continuous Bottom Lateral Bracing: 0.00 Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 7.3 PLF Filename: 16ft 2in sta Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PSF) Top 0' 0.00" 10' 6.00" 6' 6.00" 40 10 Live Replacement Uniform (PSF) Top 10' 6.00" 11' 10.00" 8' 6.00" 40 10 Live 1 2 3 10 6 0 1 4 0 11 10 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall Steel 3.500" 1.500" 1323# -- 2 10' 6.000" Wall Steel 8.000" 3.910" 5895# -- 3 11' 10.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) 3.500" 1.500" -- -3503# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 1035# 288# 2 4613# 1282# 3 -2780# -722# Design spans 10' 3.375" 1' 1.375" Product: Spruce-Pine-Fir (S) #2 2 x 10 3 ply PASSES DESIGN CHECKS Connect members with 2 rows of 16d common nails at 12.0" oc NOTE: Nails must be applied from both sides Design assumes continuous lateral bracing along the top chord. Design assumes maximum unbraced length of 0.00' along the bottom chord. Review gravity uplift reaction force of 3503lbs at bearing 3 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2630.'# 5243.'# 50% 4.33' Odd Spans D+L Negative Moment 3968.'# 5243.'# 75% 10.5' Total Load D+L Negative Unbrcd 3968.'# 5243.'# 75% 10.5' Total Load D+L Shear 1838.# 3746.# 49% 9.99' Total Load D+L Max. Reaction 5895.# 12060.# 48% 10.5' Total Load D+L LL Deflection 0.0941" 0.3427" L/999+ 4.85' Odd Spans L TL Deflection 0.1202" 0.5141" L/999+ 4.85' Odd Spans D+L Control: Negative Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 15 % This member has been designed in accordance with NDS 2012