Loading...
CS 11.87 I Joist CalcCS Structureâ„¢ 2018.9 [Build 16] kmBeamEngine 2018.9.0.1 Materials Database 1572 DadmunTomZoll - Level 8 6- 4-19 4:52pm 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcA1 Member Type: Joist Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PSF Deck Connection: Glued & Nailed Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Other Start End Dead Start End Category Replacement Uniform (PSF) Top 0' 0.00" 20' 0.00" 30 10 Live Point (PLF) Top 0' 4.63" 1 205 Live Point (PLF) Top 0' 4.63" 385 0 Snow Point (PLF) Top 19' 7.38" 1 205 Live Point (PLF) Top 19' 7.38" 385 0 Snow 1 2 20 0 0 20 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 807# -- 2 20' 0.000" Wall SPF Plate (425psi) N/A 1.500" 807# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 290#(290plf) 385#(385plf) 301#(301plf) 2 290#(290plf) 385#(385plf) 301#(301plf) Design spans 19' 2.750" Product: 11-7/8" AJS 20 12.0" O.C.PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1849.'# 4400.'# 42% 10' Total Load D+L Shear 385.# 1490.# 25% 0' Total Load D+L End Reaction 385.# 1215.# 31% 0' Total Load D+L TL Deflection 0.2965" 0.9615" L/778 10' Total Load D+L LL Deflection 0.2224" 0.6410" L/999+ 10' Total Load L Control: Pos. Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table