Loading...
CS 2nd floor girder CalcsCS Structure™ 2018.9 [Build 16] kmBeamEngine 2018.9.0.1 Materials Database 1572 DadmunTomZoll - Level 8 6- 4-19 4:53pm 1 of 3 All product names are trademarks of their respective owners Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG3 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 10.50" 263 66 Live Replacement Uniform (PLF) Top 4' 10.50" 5' 10.50" 263 66 Live Replacement Uniform (PLF) Top 5' 10.50" 7' 10.50" 263 66 Live Replacement Uniform (PLF) Top 7' 10.50" 8' 10.50" 263 66 Live 1 2 8 10 8 8 10 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1403# -- 2 8' 10.500" Girder SPF Plate (425psi) N/A N/A 1403# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 1103# 299# 2 1103# 299# Design spans 8' 4.875" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2948.'# 3431.'# 85% 4.38' Total Load D+L Shear 1145.# 2498.# 45% 7.87' Total Load D+L LL Deflection 0.1065" 0.2802" L/947 4.38' Total Load L TL Deflection 0.1354" 0.4203" L/745 4.38' Total Load D+L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2012 Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2018.9 [Build 16] kmBeamEngine 2018.9.0.1 Materials Database 1572 DadmunTomZoll - Level 8 6- 4-19 4:53pm 2 of 3 All product names are trademarks of their respective owners Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG4 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 2.75" 263 66 Live Replacement Uniform (PLF) Top 1' 2.75" 3' 2.75" 263 66 Live Replacement Uniform (PLF) Top 3' 2.75" 4' 0.00" 263 66 Live Replacement Uniform (PLF) Top 4' 0.00" 9' 3.50" 263 66 Live Point (LBS) Top 0' 4.63" 0 69 Live Point (LBS) Top 0' 4.63" 1 126 Live Point (LBS) Top 0' 4.63" 389 0 Snow 1 2 9 3 8 9 3 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1658# -- 2 9' 3.500" Wall SPF Plate (425psi) N/A 1.500" 1457# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1147# 389# 506# 2 1146# 0# 311# Design spans 8' 8.750" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 3179.'# 3431.'# 92% 4.75' Total Load D+L Shear 1199.# 2498.# 48% 8.68' Total Load D+L LL Deflection 0.1238" 0.2910" L/846 4.75' Total Load L TL Deflection 0.1574" 0.4365" L/665 4.75' Total Load D+L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2012 CS Structure™ 2018.9 [Build 16] kmBeamEngine 2018.9.0.1 Materials Database 1572 DadmunTomZoll - Level 8 6- 4-19 4:53pm 3 of 3 All product names are trademarks of their respective owners Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG5 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 18.1 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 6' 10.50" 188 63 Live Replacement Uniform (PLF) Top 6' 10.50" 17' 0.00" 27 7 Live Replacement Uniform (PLF) Top 6' 10.50" 17' 0.00" 27 7 Live Point (LBS) Top 7' 0.25" 1132 343 Live Point (LBS) Top 16' 7.38" 1 175 Live Point (LBS) Top 16' 7.38" 329 0 Snow 1 2 17 0 0 17 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 2536# -- 2 17' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1737# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1815# 0# 721# 2 1094# 329# 644# Design spans 16' 5.250" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 11076.'# 33189.'# 33% 7.02' Total Load D+L Shear 2270.# 11845.# 19% 0.19' Total Load D+L TL Deflection 0.3224" 0.8219" L/611 8.4' Total Load D+L LL Deflection 0.2317" 0.5479" L/851 8.4' Total Load L Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives