PDF File May 3_latest,5
3'-0" x 5'-0"
35,-O"
3'-0" x 5'-0" 3'-0" x 5'-0" 3'-0" x 5'-0"
3,-0" x 5,-0"
0
0
0 0
m CA
PLE46E NOTE:
ALL DIMENSIONS ARE TO BE FIELD YER/F/ED 8/NCE
EXACT OVERALL D/MFNSIONS M,4Y NOT BE EXACT
,4N0 THE FACT THAT EXISTING BU/LD/N65 .41?E NE/TNER
PLUMB NOR SQU,4RF. ADUlST ALL DIMENSIONS ,46
NEEDED TO FIT FOR THE NEW GONSTRUGTION,
All
244
I INCH = 4 FEET
10 FEET
z
o
N
00
�
d
L
z
Li
_^
-/
LU
LU
L1
F
Ld
V
�
cs
cl
O_
O
Z
10
I
L
Z
LU
O
�
U
z
O
N
~
V
z
U
z
�
A
Ld
L
0
c�
LZI.I
�
U
0
�
0
a
w
�
z~
o
wM
Q�
�Q
(Y N
0
4J
TAM
PIZA\VN eY:
TAN
SCALE:,{
1�411 = 11.011
STAMP
DATE
NOV 2023
511LI=T
M0
RED/ 5
9'-41I V 51-0II
14'-C"
CRI71C,41- NOTS:
T,LIE OVERALL 14El61-17' MUST BE VERIFIED ON S/TE
SINCE 1-IE/61-17" OF BU/LD/NCS /5 CONTROLLED
B'r T,-IE C/T'r OF NOR71LIA I=710N ZON/NC /T 6kALL
BE TILIE OF T,-IE CONTRACTOR TO
VER/F'r 71-IE TOTAL qjS/CNT WILL NOT V101-ATE T,-IE
ZONINI kEI6NT. ,AFTER T 4E CE/L /N6 JO/S TS ,ARE SET
DIMEN8/ON6 614ALL BE CHECKED AND VERIFIED
PR/OR TO THE R06E BEING SET. TkE ROOF PITCH
MA)' BE AOX67ED /N ORDER FOR FULL COMPLIANCE
TO ZON/N6 /5 TO BE AC141EYED,
N
_
C\
\
�
r
N
Oj
c�
-
AR
— -m
OF
4TER
i
N
r
m
�
N
�
m
- CEILING
N
m
0
r
0
FINISHED FLOOR -
N
m
r
O �
r O
m
O
FINISHED FLOOR
CEILING
FINISHED FLOOR
111
N
REAR ELEVATION
I,
I INCH = 4 FEET
IN
10 FEET
W e} V tY
p n L1 ib
�
O Q
Q Z3
Z
w U
4
U
Q
�LU
� O
� O
'www
U
ui
DO
��
�O
CLIECICED by,
T�VN
D2A\VN by;
TAN
.SCALE:
1/4II o V-oil
'5TAMP
DATE
DEC 2024
51LLT
MLS
REV C
BEAM ABOVE
ro'-54" x 5'-4-ha"
0I-OII
I12'-0"
FIELD VERIFY
ADDITION - SECOND FLOOR PLAN
BEAM ABOVE
v
TYPICAL 2x6 SIDING EXTERIOR WALL:
VINYL HORIZONTAL SIDING
1-1/32" ZIPWALL SHEATHING
2x6 STUDS a 24" o.c.
CLOSED CELL SPRAY INSULATION
1/2" DRYWALL
TAPED 8 SANDED
NOTE:
FINAL WINDOW SIZES AND MANUFACTURER
SHALL BE DECIDED 5Y OWNER * CONTRACTOR
PLF45F NOT�-
,4LL D/ jFNS/ONS ARE TO BF F/FL17 VERIFIED S/NCF
EXACT OVERALL ZNMEN5/ON5 MA r NOT BF EXACT
AND TIkE FACT rkA T FX/5 T/NO BU/1-D/N66 ARE NF/T,NFR
PWMa NOR SQUARE ,4DJU57.ALL D1MEN5/ON5 ,45
NEEDED TO F/T FOR 7'11IE NEW CONS 7"RUCT/ON,
INSURE THIS DURING CONSTRUCTION.
THE NEW WALL SHALL BE CONSTRUCTED SO
THE NEW DRYWALL ALIGNS WITH EXISTING WALL
REMOVE ALL SIDING 4 TRIM
TRIPLE 2x10 JOISTS
TYPICAL 2x6 SIDING EXTERIOR WALL:
VINYL HORIZONTAL SIDING
I71/32 ZIPWALL SHEATHING
2x6 STUDS e 24" o.c. MID SPAN BLOCKIN
CLOSED CELL SPRAY INSULATION
1/2" DRYWALL
TAPED 6 SANDED
6'-Bia" x
12'-OII
FIELD VERIFY
ADDITION - F-llR5T FLOOR PLAN
a P
o a
as
EXISTING FOUNDATION o
a ao a ao as
D
0
15" GRAVEL BED
Oi � DDP
O [l �— POST UP TO FLOOR JOISTS
6x6 P.T. POST
a _ �
TRIPLE P.T. 2x12 BEAM 12 FT. LONG
EZ-PIER - 4 REQUIRED
WEIGHT -150 IBS HEIGHT 54" 8" x 8" TOP
BASE SIZE IS 2 FOOT SQUARE
LOAD CAPACITY 115,000 LBS,
POST UP w/ 6x6 P.T. POST
611 6 CHECK THIS DIMENSION.
12'-0" THE NEW DRYWALL ONTO THE NEW
FIELD VERIFY 2x6 STUD WALL SHOULD ALIGN WITH
THE EXISTING DRYWALL, SEE ABOVE
FIRST FLOOR NOTES. VERIFY BY SOME
FOUNDATION PLAN DISTRUCTIVE HOLE BORING INTO WALL
AFTER ADDITION IS CONSTRUCTED
REMOVE SLIDER INSTALL DOUBLE 11 -1/&" LVL BEAM
AND REMOVE WALL THEN PATCH
REMOVE SIDING
DECK
REMOVE DECK # STAIRS
11'-4!/:2"
FOUNDATION TO FOUNDATION
EXISTING CONDITIONS 4 DEMOLITION
,AND JOIST
ISTING FOUNDATION
FLOOR JOISTS a 16" o.c.
rRIPLE 2xIO JOISTS
13/41
2%4"
12'-OII
lo
FIELD VERIFY
ADDITION - SECOND FLOOR FRAMING I=L4N
TRIPLE 2x10 JOISTS
MID SPAN BLOCKING
12'-0"
FIELD VERIFY
FIRST FLOOR FRAMING PLAN
BAND JOIST
KISTING FOUNDATION
> FLOOR JOISTS a 16" o.c.
TRIPLE 2x10 JOISTS
2,
1 INCH = 4 FEET
10 FEET
z
Q c)-'
N
00
3
z a
w Ld
o
O Z
w
z w
� v
elf u
Ld w V1
ci Q
w O
to
z
L U
F 0
s
HzA
Q Q C4
cl]Lcvs-p E'y
T\VN
w—A\VN e'y;
TLN
SCALE:
I/4" - II-0"
STAMP
DATI=.
J,4N 2024
siLLT
M=T
REV 1/15/24
1 1/4" RIMJOIST
ALL SIDES
2 x 12 RIDGE BOARD
12 TOTAL HEIGHT
CRITICAL - PLEASE SEE CAUTION NOTE
ELOW
(o
ASPHALT ROOF _
MC4
FULL COVERAGE ROOF UNDERLAYMENT
a)
Ole
01
Ole
5/0" PLYWOOD T8G ROOFING SHEATHING
�i
N
N
ASPHALT SHINGLED ROOF
I
2x10 RAFTERS w 16" o.c.
SEE NOTE-
-
m le
CENTERLINE OF ROOF m
2x4 x S FT, LONG COLLAR TIE
r
=�
ZIP SYSTEM 5/5" T8G ROOFING SHEATHING
INSTALL ON EVERY OTHER RAFTER SET
PROPER VENT
r
2x6 RAFTERS a 16"
o.c.
R60 BLOWN -IN INSULATION 2x8 CEILING JOISTS
2x8 RAISED PLATE 0R60
BLOWN -IN INSULATION
I
N
/
9 1/2" DEEP SERIES 40 I -JOISTS a 16" o.c.
1/2" CEILING SHEETROGK
TAPED 8 SANDED
DOUBLE 2x10 WINDOW HEADER
w/ 2 1/2" THICK RIGID INSULATI
(X
O �
I
_
O
LL LU
O
�
_
r
�
\fj
W
z
EXISTING FLOOR ASSEMBLY
FINSTALL NEW 3/4" THK, HARDWOOD FLOORING
cal PROPER VENT
Q RAISED 2x8 PLATE
EXISTING CEILING
z
_ _
W
Y_
LU
AAlu
ctl
EXISTING SECOND FLOOR
t—
W
\1
O
I
N
FINISHED FLOOR
I
FINISHED CEILING
�
w
T_
W
4
�
w
EXISTING FIRST FLOOR
I
(�
W
N
z
I
O
FINISHED FLOOR
4rW
4
4
-
— Z
N
} N
D°Q
D°Q
EXISTING GRADE
D4,
EXISTING BASEMENT
D4,
a;
a
.o
a;
a
.o
D
I
D
TOP OF FOOTING
0
I
14'-0"
14 -O"
21"
I INCH = 4 FEET
10 FEET
FIELD VERIFY
HOUSE GROSS SECTION
w/ NEW THIRD FLOOR
PLEASE NOTE:
.ALL ZNMENS/ONO ARE TO BE FIELD VERIFIED SINCE
OVERALL Z701MEN6/ON6 MA r NOT BE EXACT
AND THE FACT TNA T EX/O T/N6 BU/LD/N66 ARE NF/714ER
PLUMB NOR SQUARE. ADJUST ALL DIMENO/ONO AO
NEEDED 70 FITFOR TIE NEW CONSTRUCT/ON.
SOFFIT -
TOP OF WALL PLATE
TYPICAL 2x6 SIDING EXTERIOR WALL:
VINYL HORIZONTAL SIDING
mom
Il/32" ZIP SYSTEM WALL SHEATHING
al
2x6 STUDS a 24" o.c.
R19 CELLULOSE BLOWN -IN INSULATION
c
1/2" DRYWALL
TAPED 8 SANDED
CLOSED CELL INSULATION ON ALL
BAND JOISTS TO R-30
TOP OF WALL PLATE
DOUBLE 2x10 WINDOW HEADER
w/ 2 1/2" THK RIGID INSULATION
2x6 SIDING EXTERIOR WALL:
VINYL HORIZONTAL SIDING
1-T/32" ZIP SYSTEM WALL SHEATHING
TAPE ALL SHEATHING JOINTS
2x6 STUDS a 24" o.c.
RIS CELLULOSE BLOWN -IN INSULATION
1/2" DRYWALL
TAPED 8 SANDED
TRIPLE 2x10
BAND JOIST
FINISHED
CRITICAL NOrjE,-
TNF OVERALL 14EICil4T MUST BE VERIFIED ON O/TE
SINCE TIE 140CW4T OF BU/LD/NCi6 /S CONTROLLED
B r T14E C/Ti' OF N0R7'14AMP7'0N ZON/NCs. lT 614ALL
BE ryE REOPONO/B/L /T i' OF rNE CONTRAC rOR TO
VERIFr rNE rOTAL kE16147'u/lLL NOT VIOLATE 7'14E
ZON/NCs 14SC,4 r, AFTER THE CF/L/NCs JOTS TS ARE SET
DINENO/ONO 614AL1- BE CNECKEO ,AND VER/F/EO
PR/OR TO 714E R/DC=E BE/N6 SET. 714E ROOF P/TC14
MA )' BE ADJUO MP /N ORDER FOR FULL COMPL /ANCE
TO ZONING lO TO BE AC1IIEVS5).
N
m
m
v
ro
—RIDGE VENT
2x12 RIDGE BOARD
2x4 COLLAR TIE - 4 FT. LONG
r INSTALL ON EVERY OTHER SET
DOUBLE 2XIO WINDOW HEADER
w/ 2 1/2" THK RIGID INSULATION
ro
2x8 CEILING JOISTS a 16" o.c.
p 1/2" DRYWALL
O
Q
z
S,
FLOOR SYSTEM:
Z MATCH EXISTING FINISHED FLOORING
5/8' THICK SUBFLOORING
W 2x10 FLOOR JOISTS a 16" o,c,
U
F
BEAM
FLOOR SYSTEM:
MATCH EXISTING FINISHED FLOORING
5/8' THICK SUBFLOORING
U 2x10 FLOOR JOISTS a 16" o.c.
`m
z CLOSED CELL INSULATION ALL BAYS
�j 1/2" P.T. PLYWOOD BELOW
r
W
U
Q
P.T. 6" x 6" POST w/ TOP 8 BOTTOM POST CAPS
GRAVEL/ STONE
EZ PIER by EZ CRETE LLC.
12'-0"
2'
I FT,
I INCH = 4 FEET
10 FEET
REAR WALL CfROSS SECTION
FIN CEILING
EXISTING
FOUNDATION
Z "I
O U
L(1
00
L(1
3
N� �c
iF L
O �
Z Q
w
f�
10 l�
Z to .0
O
Z
L U
L
SO
V �
J U
z
tu
O`
(F
d)
z
� U
H O
Ld N m
~ N Q Q
p I
O W
LL O OQ
N z m
W J
N Nz
4 W w W z O 4
In O OZO QQm
Q D~ Q Q w
Wz w= W(X�
QW QW
LLLLYYYY Q U 4* 4 (K Q
CLIECa-D 5Y:
T\VN
PZA\VN aY
TLN
SCALE
JAN 2024
0 4
REV C
._1'-4" ._1'-4" ._1'-4" ._1'-4" ._1'-4" ._1'-4" ._1'-4" ._1'-4" ._1'-4" ._1'-4" ._1'-4" ._1'-4" ._1'-4" ._1'-4" .L
2x/o SUB FASCIA
BOARD ow
PLEASE NOTE:
ALL ZNMENSIONS ARE TO BE FIELD VERIFIED SINCE
EXACT OVERALL ZNMEN5/ON5 MBA r NOT BE EXACT
AND THE FAC T THA T EX/6 TINE 5U/LD/N66 ARE NEITHER
PWMa NOR SQUARE ADJUST ALL ZNMEN8/ON6 AS
NEEOEO TO F/T FOR 74E NEW CONSTRUCTION,
MEN
0
N
D ROOF RAFTERS,@ 16" o.c.
1', = 30 EACH SIDE
2x(o SUB FASCIA BOARD
2x12 RIDGE BOARD
2x4 x 8 FT, LONG COLLOR TIE
INSTALL ON EVERY OTHER RAFTER SET
ROOF FRAMING
SCALE: 1/4" = 1'-0"
1 1/4" THICK RIMBOARD
ALL SIDES
CEILING JOISTS
9 1/2" DP, I -JOISTS SERIES 40
I(o" o,C. QTY, = 28
1 1/4" THICK RIMBOARD
ALL SIDES
2x8 RAISED PLATE
TO SECURE RAFTERS TO
CEILINGS FRAMING
SCALE: 1/4" = 1'-0"
z
O
N
ON
N
00
�
d
0
z
L
Lv
d
z
U
7
Ld
>
u-
k T
Z�
L
Z
U
L
.J
1__IJ
V
v
�
z
N
r..�
�
U
�
L
L`—
�l
O
O
z
w
U
- F
N.
11111111
citcKEP B'Y:
TAM
DRAWN aY:
TAN
SCALE:
1/4" = 1'-O"
STAMP
DATE
JAN 2024
51ALF T
M=T
FIELD VERIFY
ASPHALT SHINGLES
2 X 10 ROOF RAFTER
ROOF SHEATHING --- 7
SIMPSON GBC CONNECTOR CLIP
EACH SIDE OF RAFTER I
2 X S PLATE FOR RAFTER
USE 2 TRUSSLOK AT EACH
JOISTS. 2 -1/S" LONG
PRE -FINISHED ALUMINUM GUTTER 4
EAVE FLASHING
2X6 FASCIA
PRE -FINISHED VINYL SOFFIT W/
EQUALLY SPACED VENTS
G-P FIBERSTRONG RIMBOARD
WALL SHEA7
S 1/2" DP. I -JOISTS
R-49 BLOWN -IN INSULATION
1/2" DRYWALL ON
TYPICAL 2X6 EXTERIOR WALL:
VINYL SIDING
Il/32" ZIP WALL SHEATHING
2X6 STUD S 6 24 " ors.
DOUBLE TOP PLATE
SINGLE BOTTOM PLATE
CLOSED CELL SPRAY INSULATION
1/2" SHEETROCK
SIDING EAYE
TYPICAL 2X6 EXTERIOR WALL:
VINYL SIDING
Il/32" ZIP WALL SHEATHING
2X6 STUDS m 24 " or —
DOUBLE TOP PLATE
SINGLE BOTTOM PLATE
CLOSED CELL SPRAY INSULATION
1/2" SHEETROCK
SEALANT AND BACKER ROD
METAL FLASHING
SEALANT AND BACKER ROD
TYPICAL 2X6 EXTERIOR WALL:
VINYL SIDING
Il/32" ZIP WALL SHEATHING
2X6 STUDS Q 24 " or-,
DOUBLE TOP PLATE
SINGLE BOTTOM PLATE
CLOSED CELL SPRAY INSULATION
1/2" SHEETROCK
MATC14 EX/67/N6 rRI ` UJORK
BUILT-UP HEADER
INTERIOR CASING
SHIMS AND INSULATION
WINDOW UNIT
WINDOW UNIT
INTERIOR CASING
2X6 SILL PLATE
SIDING WEAD AND SILL
FINISH WALL AND MOISTURE
BARRIER TO LAP FLASHING
AT WALL -- MAINTAIN GAP
BETWEEN WALL FINISH AND
ROOFING TO AVOID SOAKING
SIDEWALL FLASHING
PROVIDE HEMMED EDGE AT
FLASHING TO FORM CHANNEL
SO AS TO MAINTAIN AIR
GAP TO PREVENT CAPILLARY
ACTION
KEEP ROOFING NAILS OUT
OF FLASHING
ROOFING LAPS BASE
FLASHING 4 INCHES
BASE FLASHING WRAPS CORNERS,
EXTENDS UNDER SHINGLES AT
SIDES 4 INCHES AND LAPS
SHINGLES AT BASE MIN, 4 INCHES
FLASHING DETAILS i NOTES
CEILING JOIST or ROOF TRUSS
2-2X6 ATTIC HATCH
FRAME
3 LAYERS 1 1/2"
RIGID INSULATION
GLUED TOGETHER
1X2 STOP
1/2" DRESSED ONE SIDE
PLYWOOD ATTIC HATCH
INSULATION
1/2" DRYWALL ON
POLY VAPOR BARRIER
ATTIC HATCH
z NZZI
O �
N
00
111
� d
O Ld
Q
Ld
t
_O
Z ',Q
Lu
U
t
� U
Ld N
U
z
A
w Q
cA
Lu
Ld U
� L
�r
N �
W W
oQ
�o
aQ
W 3
O
>O
z
�o
CLIECICED SY:
TAN
I DRAWN aY:
TAN
SCALE:
1/4" = V-0"
STAMP
DATE:
JAN 2024