STEPHEN GOODENOUGH _ GOODNOUGH Cad 04-26-24 -CEPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 1PROJECT SUMMARYSCOPE OF WORKTHIS PROJECT INVOLVES THE INSTALLATION OF SOLAR PANELS. THESOLAR PANELS WILL BE RACKED USING A PRE- ENGINEERED RACKINGTHE RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DCTO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCALUTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULESENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION.DOCUMENT DESCRIPTIONTHIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OFDESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWERSYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITHAPPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOTBE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURERINSTALLATION INSTRUCTIONS. CONTRACTOR SHALL INSTALLEQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONSAND NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAYTHAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FORVERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THISDOCUMENT.1AERIAL VIEWNOT TO SCALESTREET VIEWNOT TO SCALE2PLOT MAPNOT TO SCALE3NEW PV SYSTEM: STEPHEN GOODENOUGH / GOODNOUGH16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA(42.321472, -72.676209)PV SYSTEM RATING (DC): 12.600 KWSITE DETAILSASHRAE 2% HIGH100.0°F(37.8°C)ASHRAE EXTREME LOW-21.3°F(-29.6°C)CLIMATE DATASOURCEWESTOVER AFB, MA, USA(WMO: 744910)WIND SPEED117 MPH (ASCE 7-10)RISK CATEGORYIIWIND EXPOSURECATEGORYCGROUND SNOW LOAD40 PSFDESIGN ENGINEERSIDDHARTH TEMBURNINABCEP PVIP CERTIFIEDSID@SUMMIT.SOLARPROFESSIONAL ENGINEERSCOTT WYSSLINGW CONSULTINGP.E. STRUCTURAL, PP, CME(O): (201) 874-3483ESC REQUIREDSEE PV7 NOTESFOR DETAILSINTERCONNECTION DETAILSPOINT OF CONNECTIONNEW SUPPLY SIDE ACCONNECTION PER NECARTICLE 705.12(B)(2)UTILITY SERVICE120/240V 1ɸELECTRICAL PANEL200A MAIN BREAKER,200A PANEL/BUSMODE OF INTERCONNECTIONBTM, LINE SIDE TAPSERVICE ENTRANCEOVERHEADSYSTEM INFORMATIONDC SYSTEM SIZE12.600 KWAC SYSTEM SIZE315W X 30 = 9.45 KWDC/AC RATIO1.33MODULEREC SOLAR ALPHA PURE-RSERIES 420WMLPE/INVERTERENPHASE MICROINVERTERSIQ7X-96-2-USRACKINGUNIRACATTACHMENTSSTRONGHOLD BUTYLTOTAL ARRAY AREA624.5 SQ.FT.NO. OF MODULES30ARRAY 1 AZIMUTH348°ARRAY 1 PITCH23°ARRAY 2 AZIMUTH168°ARRAY 2 PITCH23°ARRAY 3 AZIMUTH348°ARRAY 3 PITCH18°ARRAY 4 AZIMUTH-°ARRAY 4 PITCH-°ARRAY 5 AZIMUTH-°ARRAY 5 PITCH-°ARRAY 6 AZIMUTH-°ARRAY 6 PITCH-°FINANCE TYPELIGHTREACH FINANCEUTILITY NAMENATIONAL GRIDROOF TYPEASPHALT SHINGLENUMBER OF LAYER1REMOTEMONITORINGYESDIRECTORYPV1PROJECT SUMMARYPV2NOTESPV3PLOT PLANPV4SITE PLANPV5ATTACHMENT DIAGRAMPV6ATTACHMENT DETAILS & ELEVATIONPV7THREE LINE DIAGRAMPV8BILL OF MATERIALSPV8AU-BUILDER BOMPV9WARNING LABELSPV9APLACARDPV10 - PV15DATA SHEETSAPPLICABLE CODES & STANDARDBUILDINGMASSACHUSETTS: INTERNATIONALRESIDENTIAL CODE (2015 IRC)ELECTRICALMASSACHUSETTS ELECTRICALCODE (527 CMR 12.00) NFPA 70ENEC2023FIRE2021 NFPA 1, FIRE CODE ASAMENDED BY MASigned 4/26/2024 EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 2PROJECT NOTES2.1.1 SITE NOTES:2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHAREGULATIONS.2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AUTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, ORBUILDING ROOF VENTS.2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSEDELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26.2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED INACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'SINSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THEBUILDING OR STRUCTURE.2.2.1 EQUIPMENT LOCATIONS2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26.2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTEDOPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES310.15 (B)(2)(A) AND 310.15 (B)(3)(C).2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULESACCORDING TO NEC 690.34.2.2.4 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOTWITHIN SIGHT OF THE AC SERVICING DISCONNECT.2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNELACCORDING TO NEC APPLICABLE CODES.2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOORUSAGE WHEN APPROPRIATE.2.3.1 STRUCTURAL NOTES:2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TOCODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE ADESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND AMINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY,ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS.2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS.IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCALREQUIREMENTS.2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED ANDSEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSEDCONTRACTOR.2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THESPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER.2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BESTAGGERED AMONGST THE ROOF FRAMING MEMBERS.2.4.1 GROUNDING NOTES:2.4.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, ANDGROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCHUSE.2.4.3 AS IN CONVENTIONAL PV SYSTEMS, UNGROUNDED PV SYSTEMS REQUIRE ANEQUIPMENT GROUNDING CONDUCTOR. ALL METAL ELECTRICAL EQUIPMENT ANDSTRUCTURAL COMPONENTS BONDED TO GROUND, IN ACCORDANCE WITH 250.134 OR250.136(A). ONLY THE DC CONDUCTORS ARE UNGROUNDED.2.4.4 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUMNEC TABLE 250.122.2.4.5 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURECONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A).2.4.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN INMANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARENOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIEDGROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATIONREQUIREMENTS.2.4.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THATTHE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TOANOTHER MODULE.2.4.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOREDGREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119]2.4.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, AGROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47AND AHJ.2.4.10 ACCORDING TO NEC 690.47 (C)(3), UNGROUNDED SYSTEMS INVERTER MAY SIZE DCGEC ACCORDING TO EGC REQUIREMENTS OF NEC 250.122. HOWEVER, DC GEC TO BEUNSPLICED OR IRREVERSIBLY SPLICED.2.4.11 IN UNGROUNDED INVERTERS, GROUND FAULT PROTECTION IS PROVIDEDBY "ISOLATION MONITOR INTERRUPTER,” AND GROUND FAULT DETECTIONPERFORMED BY “RESIDUAL-CURRENT DETECTOR.”2.5.1 INTERCONNECTION NOTES:2.5.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 690.64(B)]2.5.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS INPUT MAY NOTEXCEED 120% OF BUSBAR RATING [NEC 705.12(D)(2)(3)].2.5.4 WHEN SUM OF THE PV SOURCES EQUALS >100% OF BUSBAR RATING, PVDEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THEBUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(D)(2)(3)].2.5.5 AT MULTIPLE INVERTERS OUTPUT COMBINER PANEL, TOTAL RATING OF ALLOVERCURRENT DEVICES SHALL NOT EXCEED AMPERAGE OF BUSBAR.HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDEDACCORDING TO NEC 705.12 (D)(2)(3)(C).2.5.6 FEEDER TAP INTERCONNECTION (LOAD SIDE) ACCORDING TO NEC 705.12(D)(2)(1)2.5.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITHSERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.422.5.8 BACKFEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT ISEXEMPT FROM ADDITIONAL FASTENING [NEC 705.12 (D)(5)].2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES:2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCHIS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TOTHE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS).2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BELOCKABLE, AND BE A VISIBLE-BREAK SWITCH.2.6.4 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED.THEREFORE BOTH MUST OPEN WHERE A DISCONNECT IS REQUIRED,ACCORDING TO NEC 690.13.2.6.5 DC DISCONNECT INTEGRATED INTO ROOFTOP DC COMBINER OR INSTALLEDWITHIN 6 FT, ACCORDING TO NEC 690.15 (C).2.6.6 RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 10 FT OF PV ARRAYOR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLEDCONDUCTORS ≤30V AND ≤240VA [NEC 690.12]. LOCATION OF LABELACCORDING TO AHJ.2.6.7 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9,AND 240.2.6.8 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED,THEREFORE BOTH REQUIRE OVER-CURRENT PROTECTION, ACCORDING TONEC 240.21. (SEE EXCEPTION IN NEC 690.9)2.6.9 IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTIONACCORDING TO NEC 690.11 AND UL1699B.2.7.1 WIRING & CONDUIT NOTES:2.7.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODEREQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING.2.7.3 ALL CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7.2.7.4 EXPOSED UNGROUNDED PV SOURCE AND OUTPUT CIRCUITS SHALL USE WIRELISTED AND IDENTIFIED AS PHOTOVOLTAIC (PV) WIRE [690.35 (D)]. PVMODULES WIRE LEADS SHALL BE LISTED FOR USE WITH UNGROUNDEDSYSTEMS, ACCORDING TO NEC 690.35 (D)(3).2.7.5 PV WIRE BLACK WIRE MAY BE FIELD-MARKED WHITE [NEC 200.6 (A)(6)].2.7.6 MODULE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY.2.7.7 ACCORDING TO NEC 200.7, UNGROUNDED SYSTEMS DC CONDUCTORSCOLORED OR MARKED AS FOLLOWS:DC POSITIVE- RED, OR OTHER COLOR EXCLUDING WHITE, GRAY ANDGREENDC NEGATIVE- BLACK, OR OTHER COLOR EXCLUDING WHITE, GRAYAND GREEN2.7.8 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS:PHASE A OR L1- BLACKPHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASEPHASE C OR L3- BLUE, YELLOW, ORANGE*, OR OTHER CONVENTIONNEUTRAL- WHITE OR GRAY* IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGETO BE MARKED ORANGE [NEC 110.15].+-NGGLOADLINEGLOADLINEGPV INVERTERMNON FUSIBLEAC DISCONNECTFUSIBLEAC DISCONNECTUTILITY/NET METERBIDIRECTIONALUTILITY ELECTRICGRIDMNGUTILITY/NET METERBIDIRECTIONALWITH METER MAIN12-+-+SOLAR MODULESON THEROOF/GROUNDLEGENDSFIRE SETBACKSTRINGSBLACK RAILBACK FEEDBREAKERELECTRICWIRE TAPSFLASHINGATTACHMENTEGC & GCBONDED ANDGROUNDEDGLOADLINENSMART/PRODUCTIONMETER-+DC/DC POWEROPTIMIZERSTESLAGENERACRESIDENTIALBATTERY OPTIONJUNCTION BOXSigned 4/26/2024 36.9'13.9'36.9'12.9'13.9'25.28'17.67'2.84'10.63'EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 3PLOT PLAN1SCALE: 1' 0'' = 1' 0''PLOT PLANNOTE: THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBINGTHE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGHDETAIL TO DEMONSTRATE COMPLIANCE WITH ALL APPLICABLE CODES ANDREGULATIONS. THE DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTEFOR FOLLOWING MANUFACTURER INSTALLATION MANUALS. INSTALLER SHALLINSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTALLATIONMANUALS. NOTHING IN THIS DOCUMENT SHOULD BE INTERPRETED IN A WAY THATOVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS.ARRAY 1#18, REC 420AA PURE-R#18, IQ7X-96-2-USTILT 23°ARRAY 2#10, REC 420AA PURE-R#10, IQ7X-96-2-USTILT 23°ARRAY 3#2, REC 420AA PURE-R#2, IQ7X-96-2-USTILT 18°MAIN SERVICE PANEL (INSIDE)PROPERTY LINEIQ COMBINER 5AC DISCONNECTUTILITY/NET METERNOTE: 3/4" OR GREATER EMT CONDUIT RUN INSIDE ATTICBROOKWOOD DRDRIVEWAYDETACHED STRUCTURE348°AZIMUTH168°AZIMUTHAZIMUTH348°Signed 4/26/2024 36.9'13.9'36.9'12.9' 13.9'JBACD MSP CPM EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 4SITE PLAN1SITE PLANSCALE: 1' 0'' = 1' 0''NOTE: THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBINGTHE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGHDETAIL TO DEMONSTRATE COMPLIANCE WITH ALL APPLICABLE CODES ANDREGULATIONS. THIS DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTEFOR FOLLOWING MANUFACTURER INSTALLATION MANUALS. INSTALLER SHALLINSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTALLATIONMANUALS. NOTHING IN THIS DOCUMENT SHOULD BE INTERPRETED IN A WAY THATOVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS.348°AZIMUTH168°AZIMUTHAZIMUTHARRAY 1#18, REC 420AA PURE-R#18, IQ7X-96-2-USTILT 23°ARRAY 2#10, REC 420AA PURE-R#10, IQ7X-96-2-USTILT 23°ARRAY 3#2, REC 420AA PURE-R#2, IQ7X-96-2-USTILT 18°348°SYSTEM INFORMATIONDC SYSTEM SIZE12.600 KWAC SYSTEM SIZE315W X 30 = 9.45 KWDC/AC RATIO1.33MODULEREC SOLAR ALPHA PURE-RSERIES 420WMLPE/INVERTERENPHASE MICROINVERTERIQ7X-96-2-USTOTAL ARRAY AREA624.5 SQ.FT.NO. OF MODULES30ARRAY 1 AZIMUTH348°ARRAY 1 PITCH23°ARRAY 2 AZIMUTH168°ARRAY 2 PITCH23°ARRAY 3 AZIMUTH348°ARRAY 3 PITCH18°UTILITY NAMENATIONAL GRIDREC 420AA PURE-R1" MODULE CLEARANCELEGENDS:MAIN SERVICE PANELAC DISCONNECTACDMSPCPIQ COMBINER 5MUTILITY/NET METERENPHASE STRINGSWITH IQ CABLEJBJUNCTION BOXCONDUIT RUNREC SOLAR ALPHAPURE-R SERIES 420W5.67'3.67'NOTE 1: EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZEDSHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUMWORKING CLEARANCES PER NEC 110.26.NOTE 2: CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY ANATIONALLY RECOGNIZED TESTING LABORATORY FOR THEINTENDED USE..NOTE 3: CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL RELATEDEQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES,RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR ACOMPLETE AND OPERATIONAL PV SYSTEM.NOTE 4: THE SYSTEM SHALL COMPLY WITH NEC ARTICLE 690, ALLMANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITYHAVING JURISDICTION'S (AHJ) APPLICABLE CODES.NOTE 5: WHERE DC PV SOURCE OR DC PV OUTPUT CIRCUITS ARE RUNINSIDE THE BUILDING, THEY SHALL BE CONTAINED IN METALRACEWAYS, TYPE MC METALCLAD CABLE, OR METALENCLOSURES FROM THE POINT OF PENETRATION INTO THEBUILDING TO THE FIRST READILY ACCESSIBLE DISCONNECTINGMEANS, PER NEC 690.31(G)NOTE 6: ABOVE DIMENSIONS ARE FOR THE RESPECTIVE ROOF PLANESMEASURED BETWEEN THE ROOF RIDGE TO THE EVE AND RAKE TO RAKENOTE: 3/4" OR GREATER EMT CONDUIT RUN INSIDE ATTICSigned 4/26/2024 11' 12'12'EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 5ATTACHMENT DIAGRAMNOTE 1: DIMENSIONS IN RED INK MEASURES THE HORIZONTAL DISTANCEBETWEEN RIDGE AND THE SIDE WALLNOTE 2: MOUNTS/ATTACHMENTS SHOULD BE INSTALLED AS PERMANUFACTURER'S INSTRUCTIONSNOTE 3: FLASHINGS ONCE INSTALLED SHOULD BE SEALED TO WATER TIGHTNOTE 4: IF THE ROOF IS DETERMINED TO BE WEAK AT THE INSTALL, STOPTHE WORK AND NOTIFY THE PROJECT ENGINEER1ATTACHMENT PLANSCALE: 1' 0'' = 1' 0''UNIRAC NXT U-MOUNT RAILSTRONGHOLD BUTYLLEGENDSARRAY 1#18, REC 420AA PURE-R#18, IQ7X-96-2-USTILT 23°ARRAY 2#10, REC 420AA PURE-R#10, IQ7X-96-2-USTILT 23°ARRAY 3#2, REC 420AA PURE-R#2, IQ7X-96-2-USTILT 18°2"X4" TRUSSES @ 24"O.C.48" MAX MOUNTSPACINGDEAD LOAD CALCULATIONSLOADQTY.LBS.TOTAL LBSMODULES3047.41422MICROINVERTER302.3871LINEAR FEET OF RAIL (ft.)2210.40189STRONGHOLD BUTYL700.3021UNIVERSAL CLAMPS720.096GROUND WEEBS170.102MISC. HARDWARE0TOTAL ARRAY WEIGHT1611AREA NAMEQTY.SQ.FT.TOTAL SQ. FT.MODULES3020.818624.54TOTAL ROOF AREA--1531.05% OF ROOF AREA COVERED BY SOLAR PV (-/-)40.79%POINT LOAD (TOTAL ARRAY WT./ATTACHMENTS), Lbs/Sq. ft.23DIST. LOAD (TOTAL ARRAY WT./TOTAL SQ.FT.), Lbs/Sq. ft.2.582"X4" TRUSS @ 24"O.C.2"X4" TRUSSES @ 24"O.C.Signed 4/26/2024 EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 6ATTACHMENT DETAILSSTRONGHOLD W/BUTYL ATTACHMENT1PART # TABLEP/NDESCRIPTIONSHBUTYLM2STRONGHOLD BUTYL ATT KIT #14S MILLSHBUTYLD2STRONGHOLD BUTYL ATT KIT #14S DARK2 1/2"3"4 1/2"1/8"BUTYL2 5/8"2X #14-14 TYPE AB SCREW,HWH, SS W/ #14 EPDM WASHERRAIL CLAMP ASSYDTD BUTYL ATT ASSY1 1/16"ADJUSTMENTUNIRAC RAIL: NXT UMOUNT2NXT COMBO CLAMP AND RL & CLMP CAP KIT3114"2"30MM TO 40MMMODULE FRAME11516"1516"11516"Signed 4/26/2024 EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 7ELECTRIC DIAGRAMNOTE 1: ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES250 & 690NOTE 2: PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKINGINTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METALPARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS.NOTE 3: GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSENOTE 4: AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWGWHEN INSULATED, #6AWG IF BARE WIRE.NOTE 5: EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45,AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHENEXPOSED TO DAMAGENOTE 6: GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, ORMARKED GREEN IF #4AWG OR LARGERNOTE 7: DISCONNECTING MEANS SHOULD BE ACCESSIBLE WITHIN 10' OF THE SUPPLY SIDECONNECTION, IT CAN BE A FUSED DISCONNECT OR A MANUALLY OPERATED CIRCUIT BREAKERNOTE 8: INSTALLATION SHOULD BE NEC 2023 CODE COMPLIANTNOTE 9: EQUIPMENT SHOULD BE SERVICE RATEDNOTE 10: WIRE SIZING SHOULD BE AS PER 690.31 (NEC 2023)NOTE 11: NEUTRAL AND GROUND SHOULD BE BONDED ONLY ONCENOTE 12: A SEPARATE GROUND ROD MUST BE INSTALLED FOR SOLAR PV AS PER 250.52 A(1) THROUGHA(8) TO MEET NEC 2023 REQUIREMENTS. THE ADDITIONAL GROUND ROD IS NOT REQUIRED AS PER250.53 A(2) EXCEPTION WHICH READS IF A SINGLE ROD, PIPE, OR PLATE GROUND ELECTRODE HAS ARESISTANCE TO EARTH OF 25 OHMS OR LESS.NOTE 13 : REPLACE THE EXISTING 200A PANEL WITH A NEW 200 A MAIN SERVICE PANEL.MICROINVERTER SYSTEMWWWENPHASEGATEWAYENPHASEPORTALENLIGHTENMULTIPLEMICROINVERTERSCOMMUNICATION DIAGRAM200A MAIN SERVICE PANEL200A MAIN BREAKER120/240VEATONNL2L1L1L2MAIN BONDING JUMPERMGRIDNEBIDIRECTIONALUTILITY METER120/240VMETER# 15822816SUPPLY SIDEINTERCONNECTIONAS PER 705.12 (B)(2)200AAEGC BURIEDOUTSIDEGLOADLINEND60A, 240V AC FUSIBLEDISCONNECT(2),50A FUSESLOCKABLE, NEMA 3R,UL LISTEDGANG OPERATED,OPEN BLADEREADILY ACCESSIBLEWITHIN 10' OF THE TAP200A MAIN BREAKERWIRE SIZING SCHEDULEWIRE IDGAUGEDESCRIPTIONA8 AWG THWN-2 COPPEREGC WIRE FROM JUNCTION BOX - GEC. #6 BARE CU WIRE ON THE ROOF BETWEEN THE RAILSB & C 10 AWG PV WIRE COPPERMODULES - MICROINVERTERS - JUNCTION BOX - IQ COMBINER 5D8 AWG THWN-2 COPPERIQ COMBINER 5 - AC DISCONNECTE6 AWG THWN-2 COPPERAC DISCONNECT - LINE SIDE TAP IN MAIN SERVICE PANEL - HOUSE/GRIDSYSTEM SUMMARYBRANCH 1BRANCH 2BRANCH 3MICROINV. MAXIMUM OUTPUT CURRENT13.10A13.10A13.10AMICROS IN SERIES101010NOMINAL STRING VOLTAGE240VTOTAL AC CURRENT39.30ATOTAL ARRAY STC POWER12600Wdc | 9450WacMAX MICROINVERTERS IN A STRING12ALLOWABLE OCPD IN ONE STRING20A123910-+-+-+-+-+123-+-+-+-+-+123-+-+-+-+-+910910#30 REC 420AA PURE-R#30 IQ7X-96-2-USNGMOBILECONNECT20A20A20A15ABCL2GATEWAYL1ENPHASE IQ CABLEENPHASE IQ CABLEENPHASE IQ CABLEJUNCTION BOX600V,UL LISTEDCT CABLEIQ COMBINER 5X-IQ-AM1-240-5(IEEE 1547:2018)#3, 20A BREAKERS#1, 15A GATEWAYNEMA 3RWIREDCOMMSNOTE: 3/4" OR GREATER EMT CONDUIT RUN INSIDE ATTICREFER NOTE 13 EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 8BILL OF MATERIALSBILL OF MATERIALSPRODUCTPART #, DESCRIPTIONQTY.MODULEREC SOLAR ALPHA PURE-R SERIES 420W SOLAR PANEL30MICROINVERTERENPHASE IQ7X-96-2-US MICROINVERTER COMPATIBLE WITH 96-CELL PV MODULES 320VA PEAK POWER MC4 DC CONNECTORS30PORTRAIT TRUNKENPHASE Q-12-10-240 EP IQ PORTRAIT TRUNK30LANDSCAPE TRUNKENPHASE Q-12-10-240 EP IQ LANDSCAPE TRUNK0TERMINAL CAPENPHASE Q-TERM-10 EP IQ TERM CAP FOR Q CABLE8SEALING CAPENPHASE Q-SEAL-10 SEALING CAP FOR Q CABLE8FEMALE FIELD CONNECTORSENPHASE Q-CONN-10F FEMALE FIELD WIREABLE CONNECTORS9MALE FIELD CONNECTORSENPHASE Q-CONN-10M MALE FIELD WIREABLE CONNECTORS9IQ COMBINER PANELENPHASE X-IQ-AM1-240-5 (IEEE 1547:2018) IQ COMBINER 5-2 80A 240V COMPLIANT IQ GATEWAY INCLUDES 2 CT-200 SPLIT1ENPHASE 20A BREAKERSCH BR220 20A 2P PLUG-IN 120/240 10 KIC CIRCUIT BREAKER3AC FUSIBLE DISCONNECTEATON DG222NRB, 60A 240V 2P 3W FUSED GENERAL DUTY NEMA3R SAFETY SWITCH DISCONNECT1DC NON FUSIBLE DISCONNECT60A IMO DC DISCONNECT-AC NON FUSIBLE DISCONNECTEATON DG222URB, 60A 240V 2P 3W FUSED GENERAL DUTY NEMA3R SAFETY SWITCH DISCONNECT-JUNCTION BOXEZSOLAR JB-1.2ROOFTOP PV J-BOX FOR ASPHALT SHINGLE W/ DIN RAIL AND FROUND BAR1CELL MODEMENPHASE CELLMODEM-M1-06-AT-05 ENPHASE MOBILE CONNECT LTE CAT M1 CELLULAR MODEM WITH 5-YEAR DATA PLAN FROMAT&T SIM FOR US PUERTO RICO US VIRGIN ISLANDS CANADA AND MEXICO FOR SYSTEM UP TO 60 MICROINVERTERS1FUSES50A, 250V BUSS FRN-R 250V FUSETRON2BACK FEED BREAKER50A EATON-PRODUCTION METERSQUARE D OVERHEAD OR UNDERGROUND METER SOCKET-CONDUIT MOUNTIRONRIDGE FM-CM-001-B KIT 4PCS CONDUIT MOUNT BLK 4PK3MAIN BREAKER 200A EATON-RAILUNIRAC 168RLD1 NXT U-MOUNT RAIL ~168'' DARK17RAIL SPLICEUNIRAC RLSPLCM2 NXT UMOUNT RAIL SPLICE10UNIVERSAL CLAMPUNIRAC CCLAMPD1 NXT UMOUNT COMBO CLAMP - DARK72ATTACHMENTSUNIRAC SHBUTYLD2 STRONGHOLD BUTYL ATT KIT COMP DRK70ACCESSORIESUNIRAC ENDCAPD1 NXT UMOUNT RL & CLMP CAP KIT24MLPE & GROUNDING LUGUNIRAC NULGMLP1 NXT UMOUNT MLPE & LUG CLAMP47 PV 8AU-BUILDER BOMEPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024 EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 9WARNING LABELSRATED FREQUENCY: ___PHASES:___RATING (kW/ kVA):___AVAILABLE FAULT CURRENT(AT OUTPUT TERMINALS):___MAXIMUM OUTPUT AND INPUT CURRENT(AT OUTPUT TERMINALS):___MAXIMUM OUTPUT AND INPUT VOLTAGE(AT OUTPUT TERMINALS):___UTILITY-INTERACTIVE CAPABLE:___ESSSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSNEC 690.56(C)(1)(a)TURN RAPIDSHUTDOWN SWITCHTO THE "OFF"POSITION TO SHUTDOWN PV SYSTEM ANDREDUCE SHOCKHAZARD IN THEARRAY.ON ALL CONDUITS, EVERY 10'ON AC DISCONNECT INSIDE AND OUTSIDENEXT TO METERON SMART METER SOCKETON INVERTERON MAIN SERVICE PANELON UTILITY METER, MAIN SERVICE PANELON MAIN SERVICE PANEL WHEN USINGBACK FEEDON INVERTERON JUNCTION BOX ON ROOFON ALL AC DISCONNECTSON ESS DISCONNECTON ATS, INVERTER, BATTERY CABINETON METERS, SERVICE PANELS, CONDUITSINVERTER, AC DISCONNECTSESSON THE NET METERUTILITY GRID, ESS AND PV SOLAR ELECTRICSYSTEMWARNING: PHOTOVOLTAICPOWER SOURCEDC JUNCTION BOXPHOTOVOLTAICSYSTEM kWh METERWARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELWARNINGSOURCES: UTILITY GRID ANDPV SOLAR ELECTRIC SYSTEMWARNINGDO NOT RELOCATETHIS OVERCURRENT DEVICEWARNINGELECTRIC SHOCK HAZARDIF GROUND FAULT IS INDICATEDALL NORMALLY GROUNDEDCONDUCTORS MAY BEUNGROUNDED AND ENERGIZEDPHOTOVOLTAIC SYSTEMEQUIPPED WITHRAPID SHUTDOWNPHOTOVOLTAIC SYSTEMAC DISCONNECTWARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEMOPERATING VOLTAGE VOLTSOPERATING CURRENT AMPSENERGY STORAGESYSTEM DISCONNECTNOMINAL ESS AC VOLTAGE: ___MAXIMUM ESS DC VOLTAGE:___WARNINGSOURCES: 1.UTILITY GRID 2.PV SOLAR 3.BATTERYWARNINGELECTRIC SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITION!PHOTOVOLTAIC SYSTEMDC DISCONNECTDUAL POWER SUPPLYSOLAR CIRCUITBREAKER IS BACKFEED!!!OPERATING VOLTAGE VDCOPERATING CURRENT AMPSMAX SYSTEM VOLTAGE VDCSHORT CIRCUIT CURRENT AMPSON SMART METER SOCKETELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH THE LINE AND LOAD SIDESMAY BE ENERGIZED IN THE OPEN POSITIONTRI POWER SUPPLYRAPID SHUTDOWNDISCONNECT 1/2RAPID SHUTDOWNDISCONNECT 2/2NOTE: PLACARD FORMAT IS PROVIDED FOR REFERENCE. INFORMATION FROMPV7, THE SINGLE LINE DIAGRAM WILL BE ADDED AND INSTALLED ON ALLAPPLICABLE UTILITY, STATE AND LOCAL REQUIRED PLACARDS USED FOR THISINSTALLATION BEFORE PROJECT INSPECTION AND COMPLETION!!ON ESS DISCONNECTON INTERACTIVE SYSTEM DISCONNECTUTILITY KWh NET METERON UTILITY METERFOR SOLAR PV SERVICING:SUMMIT ENERGY GROUP781-760-1331ON ALL AC DISCONNECTS EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 9APLACARDDIRECTORYPERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THESERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM.(ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC690.56(B) & (C), [NEC 705.10])THE REQUIREMENTS FOR THE PLACARD ARE:- MADE OF METAL OR HARD PLASTIC- HAVE A RED BACKGROUND WITH WHITE ENGRAVING- LETTERS SHOULD BE 9MM (1/4”) TALL (COMPARABLE TO 25 POINT ARIAL FONT)CAUTIONPOWER TO THIS BUILDING IS SUPPLIED FROMTHE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWNSOLAR ARRAY ONROOFTOPHOUSEDRIVEWAYBROOKWOOD DRMAIN SERVICE PANEL (INSIDE)UTILITY/NET METERAC DISCONNECTIQ COMBINER 5 EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 10MODULE DATA SHEET EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 11MICROINVERTERDATA SHEET EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 12COMBINER DATA SHEET EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 13IQ CABLE DATA SHEET EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 14ATTACHMENT DATA SHEET EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 15NXT UMOUNT DATA SHEET EPC COMPANY:SUMMIT ENERGY GROUP293 LIBBEY INDUSTRIAL PKWY,UNIT 250, WEYMOUTH,MA 02189, USA888-578-6648www.summitsolarenergy.comCUSTOMER DETAILSPAGE DESCRIPTIONPROJECT ID: MANG12.6-3826DRAWN BY:CHECKED BY:STAMPED BY:UTILITY: NATIONAL GRIDPE STAMP WITH SIGNATURESTEPHEN GOODENOUGH / GOODNOUGH RESIDENCE UNIRACS.T.S.W.16 BROOKWOOD DR, NORTHAMPTON, MA 01062, USA PHONE: (413) 374-8126 DC NAMEPLATE RATING: 12600 WPREPARED ON:4/26/2024PV 16CONNECTOR DATA SHEET