Loading...
22B-029 BP-2024-0441 11 CORTICELLI ST COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 22B-029-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2024-0441 PERMISSION IS HEREBY GRANTED TO: Project# 2024 SOLAR Contractor: License: SUNRUN INSTALLATION SERVICES Est. Cost: 8272 INC CS-090170 Const.Class: Exp.Date: 05/09/2024 Use Group: Owner: MCGUINNESS LISE A&ANDREA C HOLLAND Lot Size (sq.ft.) Zoning: URB Applicant: SUNRUN INSTALLATION SERVICES INC Applicant Address Phone: Insurance: 150 PADGETTE ST UNIT A (978)793-8584 WC614287602 CHICOPEE, MA 01022 ISSUED ON: 04/17/2024 TO PERFORM THE FOLLOWING WORK: INSTALL 1 1 PANEL 4.4 KW ROOF MOUNT SOLAR SYSTEM (NO STRUCTURAL OR BATTERY) POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: 1.72. Fees Paid: S75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner The Commonwealth of Massac use t l PR 1 6 �O24 MUNICIPALITY Massachusetts State Building Code, 780 MIA _,f USE • Building Permit Application To Construct,Repair, eno at_e Demulisl}-a— vise Mar 2011 c One-or Two-Family Dwelli DEPT.OF t3UILDING IMSPEGTiDr . This Section For Official U eOnly— —_. r` BuildinkL it Nuummbber: ����` �" gel/ Date Applied: l Ko�S ///Z 9-17-zoz Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION ilreortswea "� ' 1.2 Assessors Map&Parcel Numbers 1.1a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: _ Outside Flood Zone? Municipal ❑ On site disposal system ❑ Check if yes❑ SECTION 2: PROPERTY OW ERSHIP' 2. 5w t iii t ��i 1 /i Ma- — ' e(P e• to ZP r- - , al i No.and reet Telephone Mail Address SECTION 3: DESCRIPTION OF PROPOSED WORK' (check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units Other Ki Specify: Solar lnstalla'. •ef'ir s •.ti, • P •.os-• i . '• WINE? . SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Lab•ran at rtals 1. Building S C . di . Building Permit Fee: $ Indicate how fee is determined: 2. Electrical " . /�' Standard City/Town Application Fee • Total Project Cost3(Item 6)x multiplier x 3. Plumbing $ • 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5. Mechanical (Fire $ Suppression) Total All Fees: heck Nog) Check Amount. Cash Amount: 6.Total Project Cost: it-4 2. /' Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-090170 05/09/2024 Robert J Decker IV, IV License Number Expiration Date Name of CSL Holder List CSL Type(see below) U - 240A Cherry St,Shrewsberry, MA 01545 No.and Street Type Description U Unrestricted(Buildings up to 35,000 cu.ft.) - Chicopee,MA 01022 R • Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 413-259-8044 pioneervalleypermits@sunrun.com I Insulation _Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 180120 10/13/2024 Sunrun Installation Services Inc HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 225 Bush St Suite 1400 pioneervalleypermits@sunrun.com No.and Street Email address San Francisco,CA 94104 413-259-8044 City/Town, State,ZIP Telephone SECTION 6:WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes Ise No 0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Sunrun Installation Services Inc to act on my behalf,in all matters relative to work authorized by this building permit application. SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION B entering my name below,I hereby attest under the pains and penalties of perjury that all of the information o taine_ i this a p 'catt n s true and accurate to the best of my knowledge and unders n i g. � 11I 2/. I rint 0 is or Authorized Agent's Name(Elec roni ignature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq. ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms _ Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" Commonwealth of Massachusetts Division of.Occupational Licensure Board of Building R ulations and Standards Cons tonrS*visor 'CS-090170 z Kkplres:05/0912024 ROBERT J CKERIV N. A 77 FEDERAL�T MONTAGUE•^A 01 f 6 44-01%l Vfil'a� o .� CoMmisSioncr v aa�r ri. 'ir•.nzitA- Phone Number: 559-240-9370 THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washington SSreet- Suite 710 Boston, Massachusetts 02118 Home Impro opt n', tractor Registration I' S " Type. Supplement Card M 449t Registration: 180120 SUNRUN INSTALLATION SERVICES INC. �• _ r: Expiration: 10/13/2024 21 WORLDS FAIR DR -'z ' a _ SOMERSET,NJ 08873 =ems ro kci `," ---7::._: "N.(t 14: . Update Address and Return Card. THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs&Business Regulation Registration valid for Individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE:Sup"pfetnent Card Office of Consumer Affairs and Business Regulation Registration Expiration 1000 Washington Street -Suite 710 180120 - 10/13/2024 Boston,MA 02118 SUNRUN INSTALLATION SIEtVICErS INC. r _ ROBERT J.DECKER 11P" ,--r /1 225 BUSH STREET • '�"' ;"!sGlsM/r L SUITE 1400 . SAN FRANCISCO,CA 94104 - ' Undersecretary Not Yalid without signature The Commonwealth of Massachusetts it Department of Industrial Accidents } a 1 ;, NW 7T Office of Investigations Lafayette City Center . _ F 2 Avenue de Lafayette, Boston,MA 02111-1750 :. •y`•V www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print LeEibly Name (Business/Organization/Individual): Sunrun Installation Services Address:225 Bush St Ste 1400 City/State/Zip: San Francisco CA 94104 Phone #:415-946-7500 Are you an employer? Check the appropriate box: Type of project(required): I.U■ I am a employer with 50 4. 0 I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. ❑New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. El Building addition [No workers' comp. insurance comp. insurance.: required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no Solar Installation employees. [No workers' 13.ill Other comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.police number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: American Zurich Insurance Company Policy#or Self-ins. Lic. #:WC614287602 Expiration Date: 10/1/2024 Job Site Address:\\ CJTSS4. l .2 —a—City/State/Zip. A., Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify un r the pains and penalties of perjury that the information provided above is true and correct. Signature: i tom' Date: 9/28/2023 Phone#: Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(check one): 1DBoard of Health 20 Building Department 3.DCity/Town Clerk 4.0 Electrical Inspector 5 FI'lumbing Inspector 6.0Other Contact Person: Phone#: SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION rift? •SYSTEM SIZE 4400W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC),7-10 -)SERVICE ENTRANCE •MODULES:(11)HANWA Q-CELLS:Q.PEAK DUO BLK ASCE&2015 NDS,2023 NEC AND 2023 MA ELECTRICAL CODE 527 CMR 12.00(2023 PV-1.0 COVER SHEET L ML-G10+/T 400 NFPA 70 WTH MA AMENDMENTS),MUNICIPAL CODE,AND ALL MANUFACTURERS' PV-2.0 SITE PLAN •INVERTERS(1)SOLAREDGE TECHNOLOGIES: LISTINGS AND INSTALLATION INSTRUCTIONS. MP MAIN PANEL SE3800H-USMN •PHOTOVOLTAIC SYSTEM WILL COMPLY WTH NEC 2023. PV-3.0 LAYOUT •RACKING:TOPSPEED,ATTACHMENT DETAIL,MOUNT TO •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-4.0 ELECTRICAL WOOD DECK:SNR-DC-30004 •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOUDLY SP SUB-PANEL GROUNDED IN THE INVERTER.SYSTEM COMPLIES WTH 690.35. PV-5-0 SIGNAGE •MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. LC PV LOAD CENTER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. SM SUNRUN METER •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D). ICI DEDICATED PV METER •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. •12.18 AMPS MODULE SHORT CIRCUIT CURRENT. •15.23 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)). INV INVERTERS) •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE AC LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION O AC DISCONNECT(S) LC I DC DISCONNECT(S) CB 10 COMBINER BOX ABBREVIATIONS 17 INTERIOR EQUIPMENT L J SHOWN AS DASHED ..RC FAULT RP ENT S u n r u n - • - AGC FAULT i'�i�rUIT INTEPUPTEF ® CHIMNEY -OEM AZIMUTH Q ATTIC VENT -OMP COMPOSITION FLUSH ATTIC VENT DIRECT CURRENT #180126 o PVC PIPE VENT EXISTING VICINITY MAP CND PAC,5FTlE cT'MIT A.CHICOPEE.MA 010:^-11.S3 EHeacr sTcuArE SYSTEM 0 METAL PIPE VENT PK*.F n FOS FA%0 E,:T EATERIOR ® T-VENT 4 _ P CUSTOMER RESIDENCE: INT INTERIOR _: USE MCGUINNESS MOP MAIN SERVICE PAWL Q SATELLITE DISH •'I "N® 11 CORTICELLI ST, (IV) NEW ,,.nA,, , NORTHAMPTON,MA,01062 NTS. Nor TO SCALE FIRE SETBACKS ww TEL.(412)650-9140 oC CNJ,,MNITER "if. APN:NHAM•0000228-000029-000001 PREFAB PREFABRICATED ,..�-, HARDSCAPE ♦ PROJECT NUMBER: PSF POUNDS PER SUGARS'FOOT 224R-011MCGU —PL— PROPERTY LINE FL, PHOTOVOLTAIC. 9r«ct }'"a, - 9 DESIGNER: (415)580-6920 ex3 ROD R ARE/SHUTDOWN DEVICE SOLAR MODULES C - JANSALAMATIN TL TRANSFORMERLESS 0 SHEET TIP TOPICAL ,a 0 REV NAME DATE COMMENTS COVER SHEET VOLTS ..r ..•'''''''-' WATTS is, N41,011%( NN;es r • °4'p • REV:A 4/12/2024 —LANDSCAPE TOPSPEED �'. `',.,,,a.. 7 G 0 PAGE PV O MOUNT SCALE:NTSy„_ _ SITE PLAN-SCALE=1/16•'=1'-0" 1V / ROOF PATHWAYS • (N)ARRAY AR-02 e` (3 TYP rM�_C� ` (E)RESIDENCE FIRE SETBACKS ECM OS (18"TYP) 0 .#.. 1- Ve Yes Ami,11111111111111% ,.* 0$000' \ \ ilib* fk ,,,.. sunrun .----' .,80120 'p •• I50 PK.E P IP.TTE ST UNIT A.CNIC EE...O , A pT. PNMEO ° CUSTOMER RESIDENCE: • ° (N)ARRAY AR-01 LISE MCGUINNESS 11 CORTICELLI ST, ° ! NORTHAMPTON,MA,01062 .0 .° (E)DRIVEWAY 0 '° ROOF PATHWAYS TEL.(412)650-9140 • • ARRAY TRUE PV AREA APN:NHAM-000022&000029-000001 *PA :A (3'TYP) PITCH AZIM (SOFT) PROJECT NUMBER: NOTES: l • AR-01 30T 151' 169.1 224R-011MCGU • RESIDENCE DOES NOT CONTAIN ACTIVE FIRE is, AAR-02 31' 331" 83.4 SPRINKLERS. DESIGNER: (415)580.6920 ex JAN SALAMATIN ARRAY DETAILS: • TOTAL ROOF SURFACE AREA:857 SOFT. SHEET • TOTAL PV ARRAY AREA:232.5 SO FT. SITE PLAN • PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE REV:A 4/12/2024 AREA)'100=27.1% PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height TypeMAX DISTRIBUTED LOAD:3 PSF Max OC Minimum Number of Mounts per Max Landscape Max Portrait Span Spacing Detail Up-Slope Overhang Overhang SNOW LOAD:40 PSF WIND SPEED: COMP SHINGLE- TOPSPEED,ATTACHMENT DETAIL,MOUNT TO 117 MPH 3-SEC GUST. AR-01 TOPSPEED 1-Story TRUE CUT 2X4 RAFTERS 8'-4" 16" WOOD DECK:SNR-DC-30004 2/2 1 -5 0-10" S.S.LAG SCREW COMP SHINE- TOPSPEED,ATTACHMENT DETAIL,MOUNT TO (4)#14 X 2.25"SS SEALING SHINGLE AR-02 TOPSPEED 1-Story TRUE CUT 2X4 RAFTERS 8'-0" 16" WOOD DECK:SNR-DC-30004 2/21'-6" 0'-10" WASHER WOOD SCREWS FULLY PENETRATING THROUGH WOOD D1-AR-01-SCALE:118"=1'-0" DECK AZIM:151' ,1H OF Wg PITCH:30° tT s�� it MANOUCHEHO 4 t HAKHANANESIN ^ _ 3'— 24'-10" yI CNIL _ I " No.55892 �' F W rOj �""g 2''8„ VON A, /IIIIIIIIIIIIIIIIII I STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY ENGINEER OF ANY 5-11 POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ • MOUNT NUMBER FOR LEADINGTALLATION.DOWNSLOPEEDGE Digitally signed I SHALL MATCH REQUIREMENTS LISTED ABOVE 3' 0" • INSTALL PER TOPSPEED.'INSTALLATION MANUAL. by Man O u c h e h r • CONTRACTOR MAY SUBSTITUTE SNAPNRACK DECKTRACK MOUNTS(SNR DETAIL SNR-DC-00453) H a k h a m a n e s h i WITH A MAX OVERHANG OF 6" Date: 2024.04.12 09:55:56 -04'00' D2-AR-02-SCALE:1/8"=1'-0" AZIM:331' s u n r u n PITCH:31' e 20'-11" #180120 III PADCFTTE 51-MIT A CHIC F.E M._ITT:.I.,a, NONE FAX 0 ' ��ir r ,i '6 I"" " CUSTOMER RESIDENCE: LI�`'/� 11 MCGUINNESS, 11 CORTICELLI ST, NORTHAMPTON,MA,01062 NMI mow 10 S TEL.(412)650-9140 APN:NHAM-000022B-000029-000001 Mill PROJECT NUMBER: 224R-011MCGU DESIGNER: (415)580-6920 ex3 I JAN SALAMATIN SHEET LAYOUT REV:A 4/12/2024 PAGE PV-3.0 Template_vemen_d.?0.1 120/240 VAC SINGLE PHASE SERVICE < OMETER# NATIONAL GRID 67063281 UTILITY GRID SUPPLY SIDE TAP NOTE TOTAL PV =20A USED FOR INTERCONNECTION ON CALCULATIONS (NC1 EXISTING 100A BLADE TYPE MAIN BREAKER FUSED AC (N)LOCKABLE SOLAREDGE TECHNOLOGIES: 125A DISCONNECT BLADE TYPE SE3800H-USMN 1 AC DISCONNECT 3800 WATT INVERTER JUNCTION BOX PV MODULES MAIN BUS OR EQUIVALENT i1 1 HANWHA Q-CELLS:Q.PEAK DUO B Tr EXISTING / ML-G10+/T400 -N 125A MAIN 1m. o� • 7/. ,_,., + "/ (11)MODULES PANEL v OPTIMIZERS WIRED IN: FACILITY 20A FUSES I i 1 (1)SERIES OF(11)OPTIMIZERS LOADS—� `IUN SQUARE D SQUARE D LOAD RATED DC DISCONNECT D222NRB DU221RB WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A 3R,30A,2P COMPLIANT S440 120/240VAC 120/240VAC CONDUIT SCHEDULE TAP DEVICE MUST BE MARKED"SUITABLE FOR USE ON THE LINE SIDE OF THE SERVICE EQUIPMENT"OR EQUIVALENT # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE / (1)10 AWG THHN/THWN-2 S u n r u n 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8AWGTHHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 100PHOCETTE 7.1 UNIT A CHICFEE.A1A,Ole_;_ PHONED FA,0 CUSTOMER RESIDENCE: LISE MCGUINNESS 11 CORTICELLI ST, NORTHAMPTON,MA,01062 MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: TEL.(412)650-9140 HANWHA Q-CELLS:Q.PEAK DUO BLK MIN INPUT VOLTAGE: 8 VDC APN:NHAM-0000226-000029-000001 ML-G10+/T 400: 400 W MAX INPUT VOLTAGE 60 VDC OPEN CIRCUIT VOLTAGE 45.55 V MAX INPUT ISC: 14.5 ADC PROJECT NUMBER: MAX POWER VOLTAGE: 38.09 V MAX OUTPUT CURRENT. 15 ADC 224R-011MCGU SHORT CIRCUIT CURRENT: 12.18 A DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 JAN SALAMATIN SYSTEM SIZE: 4400 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 11 V ELECTRICAL MAX ALLOWABLE DC VOLTAGE 480 V SYSTEM SHORT CIRCUIT CURRENT: 15 A REV:A 4/12/2024 PAGE PV-4.0 re,Vate.ye,:an_a 0 La INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC NSTRUCTIONS ARE REQUIRED BY SECTION 690.OR ELECTRICAL SHOCK HAZARD IF REQUESTED BYTHE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: MI VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS.COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN LABEL LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING LOCAL ION METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S).DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2023.690.7(0) INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2023:690.13(B). 705.20(7),706.15(C) DUAL POWER SUPPLY SOURCES:UTILITY GRID WARNING: PHOTOVOLTAIC AND PV SOLAR ELECTRIC POWER SOURCE SYSTEM LABEL LOCATION: LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, UTILITY SERVICE METER AND MAN AT EACH TURN.ABOVE AND BELOW PENETRATIONS, CAUTION . SERVICE PANEL. ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. PER CODE(S):NEC 2023:705.30(C) PER CODE(S):NEC 2023:690.31(0)(2) ■ RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTKIN FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION. —SOLAR PANELS ON ROOF kI LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NEC 2023:690.12(0)(2),IFC s u n r u n OCPD(IF APPLICABLE). 2018:1204.5.3 PER CODE(S):NEC 2023:705.12(BX2) /\ — #16012C LA PV Y. A EQUIPPED ,wP,...UTE,T„",r^" .MAO,Q WITH RAPID SHUTDOWN v- MAIN PANEL(INT) Fa OE0 1.833.607.6937 ext. 0 I CUSTOMER RESIDENCE: LISE MCGUINNESS Ca, "°'"" I—SERVICE ENTRANCE 11 CORTICELLI ST, 1.855.478.3786 NORTHAMPTON,MA,01062 TURN RAPID SHUTDOWN `AC DISCONNECT 911 SWITCH TO THE"OFF' 7 TEL.(412)650-9140 POSITION TO SHUT DOWN -INVERTER (EXT) APN:NHAM•000022&000029-000001 s un ru n PV SYSTEM AND REDUCE PROJECT NUMBER: SHOCK HAZARD IN THE —AC DISCONNECT 224R-011MCGU LABEL LOCATION: ARRAY. MAN SERVICE DISCONNECT DESIGNER: (415)580-6920 ex3 • 11 CORTICELLI ST, NORTHAMPTON, MA, 01062 JAN SALAMATIN ` _LABEL LOCATION. ' SHEET ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2023:705.10(2) SIGNAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 4/12/2024 PER CODE(S):NEC 2023:690.12(D) PAGE PV-5.O Tempbte_varson_4094 A .MIGHTY N ENGINEERING CO. April 12,2024 RE: CERTIFICATION LETTER Project Address: LISE MCGUINNESS RESIDENCE 11 CORTICELLI ST NORTHAMPTON,MA,01062 Design Criteria: -Applicable Codes=2015 IRC/IBC/IEBC W/(780 CMR)MA 9th Edition,ASCE 7-10 and 2015 NDS -Risk Category=II -Wind Speed=117 mph,Exposure Category B,Partially/Fully Enclosed Method -Ground Snow Load=40 psf -ROOF AR-01:TRUE CUT 2 x 4 @ 16"OC,Roof DL=7 psf,Roof LL/SL=35 psf(Non-PV),Roof LL/SL=23.3 psf(PV) -ROOF AR-02:TRUE CUT 2 x 4 @ 16"OC,Roof DL=7 psf,Roof LL/SL=35 psf(Non-PV),Roof LL/SL=22.8 psf(PV) To Whom It May Concern, A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Existing roof structural framing has been reviewed for additional loading due to installation of PV Solar System on the roof.The structural review applies to the sections of roof that is directly supporting the solar PV system. Based on this evaluation, I certify that the alteration to the existing structure by installation of the PV system meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally,the PV module assembly including attachment hardware has been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed the requirements set forth by the referenced codes. Sincerely, =��\,ZNCF�S99cti Digitally signed by o NANWCHESH Manouchehr = HAKHANANESHI y u CIVIL*,„/"- No. 55892 Hakhamaneshi �AI p""` Date: 2024.04.12 9i*- 09:55:42 -04'00' Mighty Engineering Co 11708 Roxborough Rd Charlotte,NC 28211 I (980)689.9776 I info@mightyengineeringco.com pg 1 of 6 E/I' MIGHTY RESULTS SUMMARY • ENGINEERING CO. USE MCGUINNESS RESIDENCE, 11 CORTICELLI ST, NORTHAMPTON, MA,01062 MOUNTING PLANE STRUCTURAL EVALUATION MOUNTING PLANE ROOF PITCH RESULT GOVERNING ANALYSIS eg.) ROOF AR-01 30° IEBC IMPACT CHECK ROOF AR-02 31° IEBC IMPACT CHECK Limits of Scope of Work and Liability: The existing structure has been reviewed based on the assumption that it has been originally designed and constructed per appropriate codes. The structural analysis of the subject property is based on the provided site survey data. The calculations produced for this structure's assessment are only for the roof framing supporting the proposed PV installation referenced in the stamped plonset and were made according to generally recognized structural analysis standards and procedures.All PV modules, racking and attachment components shall be designed and installed per manufacturer's approved guidelines and specifications. These plans are not stamped for water leakage or existing damage to the structural component that was not accessed during the site survey.Prior to commencement of work, the PV system installer should verify that the existing roof and connections are in suitable condition and inspect framing noted on the certification letter and inform the Engineer of Record of any discrepancies prior to installation. The installer should also check for any damages such as water damage, cracked framing, etc. and inform the Engineer of Record of existing deficiencies which are unknown and/or were not observable during the time of survey and have not been included in this scope of work. Any change in the scope of the work shall not be accepted unless such change, addition, or deletion is approved in advance and in writing by the Engineer of Record. Mighty Engineering Co 11708 Roxborough Rd Charlotte,NC 28211 I (980)689.9776 I info@mightyengineeringco.com pg 2 of 6 NEMIGHTY LOAD CALCULATION ENGINEERING CO. ROOF AR-01 LISE MCGUINNESS RESIDENCE,11 CORTICELLI ST,NORTHAMPTON,MA,01062 PV SYSTEM DEAD LOAD(PV-DL) PV Module Weight = 2.50 psf Hardware Assembly Weight = 0.50 psf Total PV System Dead Load PV-DL= 3.00 psf ROOF DEAD LOAD(R-DL) Existing Roofing Material Weight Composite Shingle Roof 1 Layer(s) = 2.50 psf Underlayment Weight = 0.50 psf Plywood/OSB Sheathing Weight = 1.50 psf Framing Weight TRUE CUT 2 x 4 @ 16 in.O.C. = 1.09 psf No Vaulted Ceiling = 0.00 psf Miscellaneous = 1.50 psf Total Roof Dead Load R-DL= 7.10 psf REDUCED ROOF LIVE LOAD(Lr) Roof Live Load Lo= 20.00 psf Member Tributary Area At <200 ft2 ROOF AR-Ol Pitch 30°or 7/12 Tributary Area Reduction Factor R1= 1.00 Roof Slope Reduction Factor R2= 0.85 Reduced Roof Live Load,Lr=Lo(Rl)(R2) Lr= 17.00 psf SNOW LOAD Ground Snow Load pg= 40.00 psf Effective Roof Slope 30° Snow Importance Factor I,= 1.00 Snow Exposure Factor Ce= 1.00 Snow Thermal Factor Ct= 1.10 Minimum Flat Roof Snow Load pf = 35.00 psf Flat Roof Snow Load pf= 35.00 psf SLOPED ROOF SNOW LOAD ON ROOF(Non-Slippery Surfaces) Roof Slope Factor Cs-roof= 1.00 Sloped Roof Snow Load on Roof Ps-roof= 35.00 psf SLOPED ROOF SNOW LOAD ON PV PANEL(Unobstructed Slippery Surfaces) Roof Slope Factor co„= 0.67 Sloped Roof Snow Load on PV Panel == 23.30 psf Mighty Engineering Co 11708 Roxborough Rd Charlotte,NC 28211 I (980)689.9776 I info@mightyengineeringco.com pg 3 of 6 � A'MIGHTY IEBC IMPACT CHECK • ENGINEERING CO. ROOF AR-01 LISE MCGUINNESS RESIDENCE,11 CORTICELLI ST,NORTHAMPTON,MA,01062 EXISTING WITH PV PANEL Roof Dead Load(DL)= 7.10 10.10 psf Roof Live Load(Lr)= 17.00 0.00 psf Roof Snow Load(SL)= 35.00 23.30 psf EXISTING WITH PV PANEL (DL+Lr)/Cd= 19.28 11.22 psf (DL+SL)/Cd= 36.61 29.04 psf Maximum Gravity Load= 36.61 29.04 psf Load Increase(%)= -20.67% OK IEBC Provision: 2015 The requirements of section 807.4 of 2015 IEBC are met and the structure is permitted to remain unaltered. Mighty Engineering Co 11708 Roxborough Rd Charlotte,NC 28211 I (980)689.9776 I info@mightyengineeringco.com pg 4 of 6 IA.MIGHTY LOAD CALCULATION • ENGINEERING CO. ROOF AR-02 LISE MCGUINNESS RESIDENCE,11 CORTICELLI ST,NORTHAMPTON,MA,01062 PV SYSTEM DEAD LOAD(PV-DL) PV Module Weight = 2.50 psf Hardware Assembly Weight = 0.50 psf Total PV System Dead Load PV-DL= 3.00 psf ROOF DEAD LOAD(R-DL) Existing Roofing Material Weight Composite Shingle Roof 1 Layer(s) = 2.50 psf Underlayment Weight = 0.50 psf Plywood/OSB Sheathing Weight = 1.50 psf Framing Weight TRUE CUT 2 x 4 @ 16 in.O.C. = 1.09 psf No Vaulted Ceiling = 0.00 psf Miscellaneous = 1.50 psf Total Roof Dead Load R-DL= 7.10 psf REDUCED ROOF LIVE LOAD(Lr) Roof Live Load Le= 20.00 psf Member Tributary Area At <200 ft2 ROOF AR-02 Pitch 31°or 7/12 Tributary Area Reduction Factor Rl= 1.00 Roof Slope Reduction Factor R2= 0.85 Reduced Roof Live Load,Lr=Lo(Rd(R2) L,= 17.00 psf SNOW LOAD Ground Snow Load pg= 40.00 psf Effective Roof Slope 31° Snow Importance Factor I,= 1.00 Snow Exposure Factor Ce= 1.00 Snow Thermal Factor Ct= 1.10 Minimum Flat Roof Snow Load pf_m;,,= 35.00 psf Flat Roof Snow Load pf= 35.00 psf SLOPED ROOF SNOW LOAD ON ROOF(Non-Slippery Surfaces) Roof Slope Factor Cs-roof= 1.00 Sloped Roof Snow Load on Roof Ps-rod= 35.00 psf SLOPED ROOF SNOW LOAD ON PV PANEL(Unobstructed Slippery Surfaces) Roof Slope Factor cgs,= 0.65 Sloped Roof Snow Load on PV Panel Ps-pv= 22.80 psf Mighty Engineering Co 11708 Roxborough Rd Charlotte,NC 28211 I (980)689.9776 I info@mightyengineeringco.com pg 5 of 6 IA.MIGHTY IEBC IMPACT CHECK r • ENGINEERING CO. ROOF AR-02 LISE MCGUINNESS RESIDENCE,11 CORTICELLI ST,NORTHAMPTON,MA,01062 EXISTING WITH PV PANEL Roof Dead Load(DL)= 7.10 10.10 psf Roof Live Load(Lr)= 17.00 0.00 psf Roof Snow Load(SL)= 35.00 22.80 psf EXISTING WITH PV PANEL (DL+Lr)/Cd= 19.28 11.22 psf (DL+SL)/Cd= 36.61 28.61 psf Maximum Gravity Load= 36.61 28.61 psf Load Increase(%)_ -21.85% OK IEBC Provision: 2015 The requirements of section 807.4 of 2015 IEBC are met and the structure is permitted to remain unaltered. Mighty Engineering Co 11708 Roxborough Rd Charlotte,NC 28211 I (980)689.9776 I info@mightyengineeringco.com pg 6 of 6 ___,........N SUNRINC-02 TWANG .4�oR0 CERTIFICATE OF LIABILITY INSURANCE DATE9/1/2 DIYYYY) /1/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. -IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER License#0C36861 cAcr Walter Tanner Alliant Insurance Services, Inc. PHONE FAX 560 Mission St 6th Fl (A/c.No,Eat): (A/C,No): San Francisco,CA 94105 Miss,Walter.Tanner@alliant.com INSURER(S)AFFORDING COVERAGE NAIC a INSURER A:Evanston Insurance Company 35378 INSURED INSURER B:Zurich American Insurance Company 16535 Sunrun Installation Services,Inc INSURERc:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURERD: San Luis Obispo, CA 93401 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADM SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD MND POLICY NUMBER (MMIDD/YYY)) IMM/DD/YYYY) LIMITS A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE 1 XJ OCCUR MKLV5ENV104332 10/1/2023 10/1/2024 DAMAGETORENTED 1,000,000 PREMISES(Ee occurrence) $ MED EXP(Any one person) $ 5'000 PERSONAL&ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPUES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY X Fj'a LOC PRODUCTS-COMP/OP AGG $ 2,000,000 X OTHER:Retention: $200,000 Per Project Agg $ 5,000,000 B AUTOMOBILE LIABILITY (Ea MBINEeD,SINGLE LIMIT $ 2,000,000 X ANY AUTO BAP614287702 10/1/2023 10/1/2024 BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOSIRE� ONLY AUTOS D R pAMq HIRED ONLY AUTO ONLY (rannaE nt) GE $ X is3'8o°ed.: X Coll.:Not Covered Liability Ded.: $ 1,000,000 UMBRELLA LIAB _ OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ _ DED RETENTION$ $ C WORKERS COMPENSATIONX MUTE ED MLLOYS'LIABILITY R�/N ANY PROPRIETOR/PARTNER/EXECUTIVE WC614287602 10/1/2023 10/1/2024 E.L EACH ACCIDENT $ 1'000'000 (OMandatory in NHj EXCLUDED? N N/A 1,000,000 E.L DISEASE-EA EMPLOYEE $ If yea,describe under 1 000 000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ ' ' DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Workers'Compensation Policy WC614287601 Deductible:$1,000,000. Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN City of Northampton City Main St ACCORDANCE WITH THE POLICY PROVISIONS. 212Northampton,MA 01060 AUTHORIZED REPRESENTATIVE C ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD uuuu iyuI CIIvumpe IU.olof IJ I J-Do/C-wrw -orLu-C., aru IVl�OCV SEASONALITY 11 Solar production typically peaks in the summer and dips in the winter lila I This chart is for demonstration purposes only.Your solar system production will differ. 11 System overview Spring Summer Fall Winter Produces approximately 2,939 kWh/yr This chart is for demonstration purposes only.Your production may differ. Equipment Solar Panels & inverters BILLING The solar energy system and your local grid work together to power your home Service coverage SOLAR SYSTEM 90% Performance guarantee 25 years The system will produce 90%of ou- Sunrunor we pay you for the difference. Your Sunrun bill stays the same each month,even if you produce more solar energy than expected. Parts, Labor&Workmanship Three ways to pay your bill: i'any pdCt of the Syslunt U:ed" 1. Auto pay we'll repair or replace it. 25 years P y If there's an issue with the 2. MySunrun.com !nstallatiee we'll fix t 3. Over the phone at 1 (855)478-6786 Solar Roof Fasteners 10years For the first 12 months.Does not include taxes,if applicable,or$7.50 discount for auto-pay enrollment. If you violate the terms and conditions of our agreement,including but not limited to tampering with the system,we may choose to revoke warranty coverage. Our service cost and terms You can choose to stop receiving prescreened offers of credit from us and other companies by calling toll-free 888-561-8688.See prescreen notice We own the system and provide you with its electricity. I,.,!, f^ ,,.-.,., ^formation. Year 1 solar rate $0.280/kWh UTILITY GRID Year 1 total monthly payment Your local utility Includes$ ;;H discount $68.58/month Your utility bill will vary based on how much utility energy you use,when you use it,and how much surplus solar Annual payment escalator 3.50% energy you sell to the grid Deposit due today $0.00 UUGUJn311 CIIVtlIUpe IU.D IOJ IJ IJ-DD/C-.+r4J-or GU-CIJCJrU IUI.00I, lb • Your signature below indicates that (a) you're 18 years of age or older, (b) you're the owner of legal title to the Home and that every person or entity with an ownership interest in the Home has agreed to be bound by the terms of the Agreement, (c) that you have been advised on your rights to cancel this agreement,and(d)that you have read,understood,and accepted the provisions set forth in this contract. You also understand that if you do not give us a written request on which end of term option you choose 30 days before your Agreement terminates, we will automatically renew this Agreement for 5 years. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO THE DATE WE COMMENCE CONSTRUCTION AT YOUR HOME. PLEASE REVIEW THE ATTACHED NOTICES OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. Do not sign this contract if there are any blank spaces. DocuSigned by: Agreed and accepted by: vk, kti,v.itAIALss Agreed and accepted by 94A0ED078B3048E_. (Second Signer, optional): Print Name: Lise Mcguinness Print Name (Second signer, optional): Date: 4/3/2024 by: pocuSi nedby: Sales CofOtcrSigned• y Corporates na urc7 Signature Signature; 1A4C7D8A4F6648A '-D3DCA9DEB5644D6_. Print Name: Andrei Grama Print Name: Lauren Pool e Sunrun ID Number: 1873978073 Date: 4/3/2024 Title: Project Operations Contract Version 1.0 Proposal:PKV4ZV7ZR3NZ-H Version 2021 Q4V1 Proposal Id:a086000000oNDHv Agreement:a4m6Q000000hBuyQAE Template Order:320 Template Key: OT_213EA1437705 26 UUL u. iguI CIIVthUpb IU.D IOJ IJ IJ-DDl C-44r40-orLU-1 l.CurU IUL.0 L. Exhibit A ' As we detailed above, we guarantee that the System will produce at least 90% of the Estimated Production over its lifetime. Here is the Estimated Solar Output and Performance Guarantee Refund Rate, by year Estimated Solar Output and Performance Guarantee Refund Rate, by year Year Total Guarantee Output to Performance Guarantee Refund Date (kWh) Rate ($/kWh) 1 2,645 $0.281 2 5,277 $0.281 3 7,896 $0.304 4 10,501 $0.304 5 13,094 $0.329 6 15,674 $0.329 7 18,240 $0.356 8 20,794 $0.356 9 23,335 $0.385 10 25,864 $0.385 11 28,380 $0.416 12 30,883 $0.416 13 33,373 $0.450 Contract Version 1.0 Proposal:PKV4ZV7ZR3NZ-H Version 2021 Q4V1 Proposal Id:a086Q00000oNDHv Agreement:a4m6Q000000hBuyQAE Template Order:32 Template Key:0T_048UAE792318 27 uuI:uollyll CIIVCIUNtl IU.D IOJ I:)IJ-DDI C-4r4J-Or LU-Cl.CurL)IUL,OCI+ 14 35,852 $0.450 15 38,317 $0.487 16 40,771 $0.487 17 43,212 $0.527 18 45,641 $0.527 19 48,058 $0.571 20 50,463 $0.571 21 52,856 $0.617 22 55,237 $0.617 23 57,605 $0.668 24 59,963 $0.668 25 62,308 $0.721 Contract Version 1.0 Proposal:PKV4ZV7ZR3NZ-H Version 2021 Q4V1 Proposal Id:a086Q00000oNDHv Agreement:a4m6Q000000hBuyQAE Template Order:32 Template Key:0T_048UAE792318 28