78 Maynard HVAC 3-6-20SUBMITTAL
Project
78 Maynard Street
Date
Friday, March 6, 2020
Table Of Contents
Project: 78 Maynard Street 03/06/2020
Prepared By:
Residential Carrier Products Bldr 1.29n Page 2 of 13
Split System Furnace...........................................................................................................................................................3
Unit Report............................................................................................................................................................................................... 4
Performance Summary............................................................................................................................................................................. 6
System Parameters.................................................................................................................................................................................. 6
Electrical Data.......................................................................................................................................................................................... 6
Acoustic Summary ................................................................................................................................................................................... 7
Certified Drawing...................................................................................................................................................................................... 8
Unit Feature Sheet................................................................................................................................................................................. 11
Infinity Controls....................................................................................................................................................................................... 14
ERV........................................................................................................................................................................................................ 20
Note: Please confirm damper sizes.
Split System Furnace
Project: 78 Maynard Street 03/06/2020
Prepared By:
Residential Carrier Products Bldr 1.29n Page 3 of 13
Split System Furnace
Split System Furnace
Submittal Cover Sheet
Unit Report
Performance Summary Report
Acoustic Summary
Certified Drawings
Feature Sheet
Unit Report For Split System Furnace
Project: 78 Maynard Street 03/06/2020
Prepared By:
Residential Carrier Products Bldr 1.29n Page 4 of 13
Unit Report
Outdoor Unit Parameters
Unit Model:.............................................24ANB
Unit Size:................................3 Tons (Size 36)
Voltage:........................................208/230-1-60 V-Ph-Hz
Indoor Coil Parameters
Unit Model:..............................................CNPV
Unit Size:................................3 Tons (Size 36)
Cabinet Finish:.....................................Painted
Cabinet Width:.......................................17 inch
Refrigerant Type: ....................................Puron
Outdoor Unit Dimensions and Weight
Unit Length:..........................................31.1875 in
Unit Width: ...........................................31.1875 in
Unit Height: ...................................................36 in
Unit Shipping Weight:.................................275.lb
Indoor Coil Dimensions and Weight
Unit Length:...................................................21 in
Unit Width:..................................................17.5 in
Unit Height: ...................................................17 in
Unit Shipping Weight:.................................48.5 lb
RESIDENTIAL APPLICATIONS
This warranty is to the original purchasing owner and subsequent owners only to the extent and as stated in the Warranty Conditions and
below. The limited warranty period in years, depending on the part and the claimant, is as shown in the table below.
Limited Warranty (Years)
Item Original Owner Subsequent Owner
Parts 10* (or 5)5
Compressor 10* (or 5)5
*If properly registered within 90 days of original installation, otherwise 5 years (except in California and Quebec and other jurisdictions that
prohibit warranty benefits conditioned on registration). See Warranty Conditions below.
OTHER APPLICATIONS
The warranty period is five (5) years on the compressor, and one (1) year on all other parts. The warranty is the original owner only and isnot available for subsequent owners.
Ordering Information
Part Number Description Quantity
Outdoor Unit
24ANB736A003 Infinity Series Two-Stage Air Conditioner w/ Puron 3 Tons Cooling 1
17 SEER @ ARI Conditions
Accessories
SYSTXCCITC01-B Infinity Touch Wi-Fi Control for Outdoor Unit 1
SYSTXCCSMS01-B Infinity Smart Sensor for Outdoor Unit 2
Indoor Coil
CNPVP3617ALA Cased Vertical N-Coil Evaporator Coil with Puron 1
Painted
17 inch
Aluminum
Furnace
59TN6B060C17--14 59TN6 Infinity +96 Two Stage Condensing Gas Furnace 1
+96 AFUE
60,000 Btuh (Size 060)
Unit Report For Split System Furnace
Project: 78 Maynard Street 03/06/2020
Prepared By:
Residential Carrier Products Bldr 1.29n Page 5 of 13
Up to 1400 Clg CFM on Evap Coil
Comm. Variable Speed
17.5 inches
Furnace Parameters and Dimensions and Weight
Furnace:SEER Enhancing Furnace
Furnace Model:59TN
Furnace Efficiency:+96 AFUE
Htg Capacity:60,000 Btuh (Size 060)
Airflow:Up to 1400 Clg CFM on Evap Coil
Unit Length:29.50 in
Unit Width:17.50 in
Unit Height:35.00 in
Unit Shipping Weight:151.lb
The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product
literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information.
Performance Summary For Split System Furnace
Project: 78 Maynard Street 03/06/2020
Prepared By:
Residential Carrier Products Bldr 1.29n Page 6 of 13
Performance Summary
System Performance
System:............................................24ANB/CNPV
System Quantity:.............................................1
Altitude:........................................................0.0 ft
Furnace Type:...................59TN6B060C17**14
Linear Pipe Length:....................................50.0 ft
SEER @ ARI Conditions:...........................15.0
EER @ ARI Conditions:.............................12.5
Actual Clg Airflow:..................................1200.0 CFM
Standard Clg Airflow: .............................1200.0 CFM
Total Net Clg Capacity:............................35.29 MBH
Net Sensible Clg Capacity: ......................26.10 MBH
Total System Power:..................................2.79 kW
System Parameters
System Parameters
Outdoor Unit Parameters
Unit Model:..............................24ANB736A003
Unit Size (Nominal):...............3 Tons (Size 36)
Voltage:........................................208/230-1-60 V-Ph-Hz
Clg Ent Air DB Ambient:.............................95.0 °F
Indoor Coil Parameters
Unit Model:.............................CNPVP3617ALA
Unit Size (Nominal):...............3 Tons (Size 36)
Ent Air DB: ...............................................80.00 °F
Ent Air WB:...............................................67.00 °F
Ent Enthalpy:............................................31.44 BTU/lb
Lvg Air DB:...............................................59.86 °F
Lvg Air WB:..............................................57.80 °F
Lvg Enthalpy: ...........................................24.90 BTU/lb
Total External Static Pressure:...................0.20 in wg
Furnace Ratings
Furnace:............................59TN6B060C17--14
Furnace Efficiency:...........................+96 AFUE
Furnace Efficiency ICS:..............................96.3 AFUE
Input Max Heat:......................................60,000 BTU/hr
Input Min Heat:.......................................39,000 BTU/hr
Output Max Heat:...................................58,000 BTU/hr
Output Min Heat:....................................38,000 BTU/hr
Furnace Performance
Certified Temp High Rise Range:.............35-65 F
Certified Temp Low Rise Range: .............30-60 F
The customer must ensure the specified airflow and static pressure are within furnace capabilities.
Electrical Data
Electrical Data
Outdoor Electrical Data
Unit Voltage: ................................208/230-1-60 V-Ph-Hz
Fan Motor FLA:..........................................0.70 Amps
MCA:..........................................................19.8 Amps
Max Fuse:.....................................................35 Amps
Operating Range Min:.................................197 V
Operating Range Max:................................253 V
Compressor RLA:.......................................15.3 Amps
Compressor LRA:.......................................83.0 Amps
Furnace Electrical Data
Unit Voltage:........................................115-1-60 V-Ph-Hz
Unit MCA:.....................................................9.3 Amps
Unit MOCP:...................................................15 Amps
The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product
literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information.
Acoustic Summary For Split System Furnace
Project: 78 Maynard Street 03/06/2020
Prepared By:
Residential Carrier Products Bldr 1.29n Page 7 of 13
Acoustic Summary
Outdoor Unit Parameters:
Unit Model:...................................................................................................................................................................24ANB
Unit Size:.......................................................................................................................................................3 Tons (Size 36)
Variations:................................................................................................................................................................Standard
Octave Band Center Frequency, Hz 125 250 500 1k 2k 4k 8k dBA
Sound Power,dB 53.0 59.0 64.5 64.5 61.5 59.5 52.5
A-Weighted Sound Power, dBA 70.0
Indoor Coil Parameters:
Unit Model:CNPV
Unit Size:3 Tons (Size 36)
Cabinet Finish:Painted
Cabinet Width:17 inch
No Indoor sound data available.
The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product
literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information.
Certified Drawing For Split System Furnace
Project: 78 Maynard Street 03/06/2020
Prepared By:
Residential Carrier Products Bldr 1.29n Page 8 of 13
CertifiedDrawing
Outdoor Model
Unit Model:.............................................24ANB
Unit Size:................................3 Tons (Size 36)
Voltage:........................................208/230-1-60 V-Ph-Hz
SEER: ...........................................................17
PartNumber:............................24ANB736A003
Shipping Dimensions and Weights Outdoor Unit
Height 43.38 in
Width 33.31 in
Length 33.31 in
Operating Weight 236. lb
Shipping Weight 275. lb
Dimensions
A B C D E F G H I J K
31.19 in 36.00 in 0.88 in 6.56 in 24.69 in 9.13 in 0.31 in 3.00 in 16.00 in 15.50 in 17.50 in
The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at
www.ahridirectory.org for the most up-to-date information.
Certified Drawing For Split System Furnace
Project: 78 Maynard Street 03/06/2020
Prepared By:
Residential Carrier Products Bldr 1.29n Page 9 of 13
Indoor Coil
Unit Model:CNPV
Unit Size:3 Tons (Size 36)
Cabinet Finish:Painted
Cabinet Width:17 inch
PartNumber:CNPVP3617ALA
Dimensions and Weights Indoor Coil
Height 17.00 in
Width 17.50 in
Length 21.00 in
Shipping Weight 48.5 lb
Dimensions
A B C D E F
17.00 in 13.88 in 3.56 in 15.75 in 17.50 in 0.75 in
The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at
www.ahridirectory.org for the most up-to-date information.
Certified Drawing For Split System Furnace
Project: 78 Maynard Street 03/06/2020
Prepared By:
Residential Carrier Products Bldr 1.29n Page 10 of 13
Furnace Model:..........................................59TN
Furnace Efficiency:...........................+96 AFUE
Htg Capacity: ............60,000 Btuh (Size 060)
Airflow:.......Up to 1400 Clg CFM on Evap Coil
PartNumber:......................59TN6B060C17--14
Dimensions
A B C D Shipping Wgt
17.50 in 15.88 in 16.00 in 8.75 in 151.00 in
The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at
www.ahridirectory.org for the most up-to-date information.
Residential Carrier Products Bldr 1.29n Page 11 of 13
Unit Feature Sheet
Residential Carrier Products Bldr 1.29n Page 12 of 13
Residential Carrier Products Bldr 1.29n Page 13 of 13
SYSTXCCITC01---B, SYSTXCCWIC01---B,SYSTXCCICF01---B, SYSTXCCWIF01---BInfinityrSystem Control
Product Data
A170203 A180218C
NOTE: Infinityr System Control compatible with Infinityr rated
indoor equipment only.
US Patents: Carrierr U.S. Pat No. 7,243,004, Carrierr U.S. Pat No. 7,775,452,
pointSETt U.S. Pat No. 7,415,102
INFINITYR SYSTEM CONTROL
Carrier specializes in creating a customized home comfort system
tailored to your needs with our broad selection of residential
heating and cooling products. The Infinityr System Control is the
ultimate control center for all of your system components. When
you add an Infinityr System Control to a compatible variable
speed furnace, fan coil, Infinityr System split or package unit, or
small packaged product, you will enjoy longer heating and cooling
cycles at lower fan speeds for a more consistent temperature
throughout your home. By adding a variable speed, multi--stage, or
2--stage outdoor unit, you will enjoy extra benefits which include
better humidity and temperature control as well as a more energy
efficient comfort system. When paired with Infinityr Zoning
controls, the Infinityr System Control allows you to create up to 8
zones of customized comfort.
The Infinityr Zoning system does not require a bypass damper,
leaving air temperature (LAT) sensor, or field--installed power
transformer.
Always install the latest version of software to enable all features of
the system.
Over--the--Air software updates for Wi--Fi models connected to the
Infinity server are automatically downloaded. Software updates
via MicroSD are available on HVACpartners, or at
www.MyInfinityTouch.com.
Wi --- Fir is a registered trademark of Wi---Fi Alliance Corporation.Amazon Alexa is a trademark of Amazon, Inc. or its affiliates.
INDUSTRY LEADING FEATURES/BENEFITS
Carrier’s revolutionary Infinityr System Control is the smart
control of the future. Its unique system self--configuration and
diagnostics capabilities make installation and service fast and
accurate, helping to avoid costly call--backs. The Infinityr System
Control features a high resolution display, making it easier to read.
Intuitive prompts let you program everything from humidity levels
to fan speeds, giving you the ultimate control over your home
comfort. Other features include:
— 4--wire installation from each major component in the
system
— 2--wire connection to Infinityr System two or more stage
outdoor equipment (including geothermal split units)
— Infinityr Zoning System compatibility
— Occupancy sensing to provide comfort when spaces are
occupied and energy savings when they’re not
— Intuitive on screen prompts for ease of installation and
service
—Ideal Humidity Systemt settings are the default; no
longer requiring increased system setup
— Complete integration of the temperature, humidity and
ventilation in every season
— For Zoned Systems, auto mode selection to satisfy
simultaneous heating and cooling demands in different
zones via more aggressive Auto Changeover
algorithm----installer must enable
— 7--day programmability with Lifestyle Comfort Profiles
and Touch--N--Gor features; complies with California
Title 24 programmability requirements
— Easy timed--override schedule
— Simplified vacation schedules
— Day--at--a--glance programming for simplified ease of use
— Programmable fan by period
— TrueSenset Dirty Filter Detection
— Indoor Air Quality pop up service reminders
— General maintenance reminder messaging
—Wi--Firremote access capability
— Upload photo, dealer info, and software updates locally via
MicroSD card. Software updates available automatically
when connected to the Infinity web server
— Compatible with home automation through the
SYSTXCCRCT01 or SYSTXCCRWF01 system access
modules, or via the Côr Home Automation app or
Amazon ™Alexa ™interface.
— Compatible with Infinityr System geothermal products
(GC and GZ models). Energy Tracking feature for
geothermal systems is available with Entering Water
Temperature sensor installed in heat pump.
2
MODEL NUMBER NOMENCLATURE
1 2 3 4 5 6 7 8 9 10 11 12 13 14
SYSTXCCITC01--B
Product Type Version
Infinityr System B
Packaged Quantity
Brand / Product 01
CC = Carrier
XX or NN = No Brand Model Type
ITC --- Black Infinityr System Control with Wi --- Fi
WIC--- White Infinityr System Control with Wi --- FiICF --- Black Infinityr System Control with Wi---Fi (withFrench Literature)WIF--- White Infinityr System Control with Wi---Fi (with
French Literature)
A170101
Fig. 1 -- Unit Dimensions
3
PRODUCT DATA INFORMATION
Compatible Communicating Products
Compatible with most Infinityr System indoor and outdoor
equipment built since 2004; see equipment specifications for
details.
Home Automation System Interface
A cloud--to--cloud Open API (Application Program Interface) is
available for the ITC and ITW model Infinity Touch and Infinity
System Controls. See the Infinity Systems Open API Getting
Started Guide available on www.HVACpartners.com or contact
InfinityOpenAPI@carrier.utc.com for more information. The
Infinityr System control may also connect to a variety of Home
Automation systems using SAM modules. Note that not all Home
Automation systems may be compatible. Reference the latest
version of the Application Specification titled “SAM Remote
Access Application Specification,” available on
HVACpartners.com to learn more about the latest Home
Automation interfaces to the Infinityr systems. Work with the
home automation supplier to see if the systems are compatible. If
not, you may provide the “Infinity System Open API Getting
Started Guide” or the “SAM Remote Access Application
Specification” to the home automation supplier to develop an
interface with the Infinityr System. Always be sure to obtain the
latest version of the application specification from HVACpartners,
as we continually update and add home automation interfaces.
NOTE: The ability to remotely access and adjust the settings of
the Infinityr System Control with the MyInfinity web and mobile
applications is dependent on the compatibility of the user’s
computer, home network and/or mobile device, the Infinityr
System Control, and/or the MyInfinity web server or other system
interfaces with, and the availability of, the user’s internet service
provider or mobile device carrier service. Carrier Corporation
makes no representations or warranties, express or implied,
including, to the extent permitted by applicable law, any implied
warranty of merchantability or fitness for a particular purpose or
use, about the compatibility of the user’s computer, home network,
and/or mobile device, with the Infinityr System Control, and/or
the MyInfinity web server or other system interfaces, with, and the
availability of, the user’s internet service provider or mobile device
carrier service, or that the ability to remotely access and adjust the
settings of the Infinityr System Control will not be negatively
affected by the network--related modifications, upgrades, or similar
activity of the user’s internet service provider or mobile device
carrier service.
Physical Characteristics
Dimensions:See drawing
Appearance:Black glass front, silver plastic body
Electrical Characteristics/Communication
Input Volts/Amps 24VAC
Each device in the Infinityr System has a four--pin connector
labeled ABCD. It is recommended that the following color
code be used when wiring each device:
A — Green = Data A+
B — Yellow = Data B--
C — White = 24VAC (Com)
D — Red = 24VAC (Hot)
Always verify that the IDU and ODU are well--grounded,
and that there are less than 10 volts AC/DC as measured
between the cabinets of the IDU and ODU, while the
equipment is operating at full capacity. If there is a larger
voltage difference between the cabinets of the IDU and
ODU, recheck the equipment grounding.
Environmental Requirements:
Operating Temperature/Relative Humidity:
User interface and all sensors: 32_F to 104_F/0_Cto40_C,
95% RH non--condensing
Feature Specifications:
Temperature set point range: 50_Fto90_F / 10.0_C to 32.0_C
Separate heat and cool setpoints
Programming days: 7 day
Programming periods: Up to 5 periods per day
Advanced Smart Setback (with programming)
Touch--N--Gor feature
Occupancy Sensing
Non--Programmable (installer selectable)
Auto Changeover* (may be disabled)
Simultaneous Heat Cool Demand Algorithm for zoned systems
Programmable fan (installer selectable)
Humidity Sensor Offsets
Auto Changeover Timer (installer adjustable)
Smart Recovery (in heating and cooling)
Hold function
Copy functions: copy day of week; copy zones
Permanent memory
Humidity display and control
Temperature sensor offsets (indoor and outdoor)
TrueSenset Dirty Filter Detection with compatible indoor
equipment
* See Installation Instructions for details on Auto Changeover and
Simultaneous Heat/Cool Demand Algorithm operation.
Wiring Requirements:
Power supply:24VAC, 40 VA (minimum), 60 Hz, via indoor
equipment ABCD Connector. Zoning systems with a large
number of dampers, especially multiple dampers per zone, may
require a separate, dedicated, field--installed 24VAC power
supply. The SAM module requires an independent, isolated,
field--supplied 24VAC power supply.
Wiring material:Standard thermostat wire 18 to 22 gauge.
Use 18 AWG wiring for wire lengths over 25 feet. Shielded,
twisted pair cable for te ABCD communication bus is optional,
and may be helpful in electrically noisy environments, or for
zoning systems with Smart Sensors.
NIM Requirements:
IDU NON---COMMUNICATINGODU NIMREQUIRED?
Furnace 1 --- stage A/C No
Furnace 2 --- stage A/C Yes
Furnace 1 --- stage HP Yes
Furnace 2 --- stage HP Yes
Fan Coil 1 --- stage A/C No
Fan Coil 2 --- stage A/C Yes
Fan Coil 1 --- stage HP No
Fan Coil 2 --- stage HP Yes
4
CONTROLS
DESCRIPTION PART NO.
Infinityr System Control with Wi --- Fi r Remote Access Capability (Black)SYSTXCCITC01---B
Infinityr System Control with Wi --- Fi r Remote Access Capability (White)SYSTXCCWIC01---B
Infinityr System Control with Wi --- Fi r Remote Access Capability (Black with French Literature)SYSTXCCICF01---B
Infinityr System Control with Wi --- Fi r Remote Access Capability (White with French Literature)SYSTXCCWIF01---B
Infinityr Network Interface Module (NIM)SYSTXCCNIM01*
* Required for ventilator control* Required for Hybrid Heat applications with non---communicating heat pumps* Required for use with 2---stage (non---communicating) AC or HP
ZONING CONTROLS
DESCRIPTION PART NO.
Infinityr Damper Control Module (4 Zone)SYSTXCC4ZC01†
Infinityr Smart Sensor SYSTXCCSMS01-B
* NOTE: Each piece of the zoning equipment is purchased separately allowing for customization of the zoning application.**Smart Sensor dimensions are 3.375 in. (85mm) side x 4 in. (101 mm) high
{One Damper Control Module for up to 4 zones. A second Damper Control Module is required for zones 5–8.
OPTIONAL ACCESSORIES
DESCRIPTION PART NO.
Infinityr Remote Room Sensor --- Wired (RRS)SYSTXCCRRS01*
Decorative Trim Plate --- Silver (six pack)SYSTXNNSBP06{
Decorative Trim Plate --- White (six pack)SYSTXNNWBP06{
Decorative Trim Plate --- Black (six pack)SYSTXNNBBP06{
Decorative Trim Plate --- Gray (six pack)SYSTXNNGBP06{
ABCD Equipment Communication Connector (Green Plug; 10 pack)SYSTXGRPLG10
Outdoor Air Temperature Sensor TSTATXXSEN01---B
Energy Tracking Kit (EWT) for GC and GZ Geothermal Heat Pumps KHAGT0101KIT**
Infinityr Remote Access Module, Broadband Cat---5 Wired (SAM)SYSTXCCRCT01
Accessory Power Transformer for SAM Modules**SYSTXNNXFM01**
* Not required, but may be used to remote sense indoor room temperature.
{Backplate dimensions 6.83 in. (173.5 mm) wide X 5.97 in. (151.7 mm) high
** Available from RC/Totaline.
DAMPER ACCESSORIES & REPLACEMENT PARTS
DESCRIPTION PART NO.
45º Actuator for round dampers DAMPACT45DEG-R
90º Actuator for rectangular dampers DAMPACT90DEG-R
Damper Control Module 1-amp Fuse ATO1*
*Available from RC.
ROUND & RECTANGULAR DAMPERS
DESCRIPTION PART NO.
Round Dampers
6in.DAMPRND06INC-B
8in.DAMPRND08INC-B
10 in.DAMPRND10INC-B
12 in.DAMPRND12INC-B
14 in.DAMPRND14INC-B
16 in.DAMPRND16INC-B
Rectangular Dampers
8in.X10in.DAMPREC08X10-B
8in.X14in.DAMPREC08X14-B
8in.X18in.DAMPREC08X18-B
8in.X24in.DAMPREC08X24-B
10 in. X 10 in.DAMPREC10X10-B
10 in. X 14 in.DAMPREC10X14-B
10 in. X 18 in.DAMPREC10X18-B
10 in. X 24 in.DAMPREC10X24-B
TBD
5
SLIP--IN DAMPERS
DESCRIPTION PART NO.
Slip-In Dampers
Side mount, 8 X 8 DAMPSLS08X08-B
Bottom mount, 8 X 8 DAMPSLB08X08-B
Side mount, 8 X 10 DAMPSLS08X10-B
Bottom mount, 8 X 10 DAMPSLB08X10-B
Side mount, 8 X 12 DAMPSLS08X12-B
Bottom mount, 8 X 12 DAMPSLB08X12-B
Side mount, 8 X 14 DAMPSLS08X14-B
Bottom mount, 8 X 14 DAMPSLB08X14-B
Side mount, 8 X 16 DAMPSLS08X16-B
Bottom mount, 8 X 16 DAMPSLB08X16-B
Side mount, 8 X 18 DAMPSLS08x18-B
Bottom mount, 8 X 18 DAMPSLB08X18-B
Side mount, 8 X 20 DAMPSLS08X20-B
Bottom mount, 8 X 20 DAMPSLB08X20-B
Side mount, 8 X 22 DAMPSLS08X22-B
Bottom mount, 8 X 22 DAMPSLB08X22-B
Side mount, 8 X 24 DAMPSLS08X24-B
Bottom mount, 8 X 24 DAMPSLB08X24-B
Side mount, 10 X 10 DAMPSLS10X10-B
Bottom mount, 10 X 10 DAMPSLB10X10-B
Side mount, 10 X 12 DAMPSLS10X12-B
Bottom mount, 10 X 12 DAMPSLB10X12-B
Side mount, 10 X 14 DAMPSLS10X14-B
Bottom mount, 10 X 14 DAMPSLB10X14-B
Side mount, 10 X 16 DAMPSLS10X16-B
Bottom mount, 10 X 16 DAMPSLB10X16-B
Side mount, 10 X 18 DAMPSLS10X18-B
Bottom mount, 10 X18 DAMPSLB10X18-B
Side mount, 10 X 20 DAMPSLS10X20-B
Bottom mount, 10 X 20 DAMPSLB10X20-B
Side mount, 10 X 22 DAMPSLS10X22-B
Bottom mount, 10 X 22 DAMPSLB10X22-B
Side mount, 10 X 24 DAMPSLS10X24-B
Bottom mount, 10 X 24 DAMPSLB10X24-B
Side mount, 12 X 12 DAMPSLS12X12-B
Bottom mount, 12 X 12 DAMPSLB12X12-B
Side mount, 12 X 14 DAMPSLS12X14-B
Bottom mount, 12 X 14 DAMPSLB12X14-B
Side mount, 12 X 16 DAMPSLS12X16-B
Bottom mount, 12 X 16 DAMPSLB12X16-B
Side mount, 12 X 18 DAMPSLS12X18-B
Bottom mount, 12 X 18 DAMPSLB12X18-B
Side mount, 12 X 20 DAMPSLS12X20-B
Bottom mount, 12 X 20 DAMPSLB12X20-B
Side mount, 14 X 14 DAMPSLS14X14-B
Bottom mount, 14 X 14 DAMPSLB14X14-B
Side mount, 14 X 16 DAMPSLS14X16-B
Bottom mount, 14 X 16 DAMPSLB14X16-B
Side mount, 14 X 20 DAMPSLS14X20-B
Bottom mount, 14 X 20 DAMPSLB14X20-B
Side mount, 16 X 16 DAMPSLS16X16-B
Bottom mount, 16 X 16 DAMPSLB16X16-B
Bottom mount, 16 X 20 DAMPSLB16X20-B
TBD
6
Copyright 2019 CarrierCorp.S 7310 W. Morris St.S Indianapolis, IN 46231 . Edition Date: 07/19
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Catalog No: SYSTXCCITC--05PD
Replaces: SYSTXCCITC--04PD
HRVCR
Heat Recovery Ventilators
ERVCR
Energy Recovery Ventilators
Product Data
A05229
ERVCRSVB1100, HRVCRSVB1100
A05330ERVCRSHB1100, HRVCRSHB1100
A12338
HRVCRSVU1157
A13212ERVCRNVA
A10299
ERVCRLHB1200, HRVCRLHB1150, HRVCRLHB1250
The Carrier Heat Recovery Ventilation (HRV) and Energy
Recovery Ventilator (ERV) systems are the finest on the market
today. These units provide efficient and cost effective heat recovery
during the heating season when needed most.
As temperatures drop below 23 F (−5 C), indoor air is recirculated
periodically through the heat exchanger core to prevent frost from
forming.* Competitors’ methods of supplementary electric defrost
waste energy. Unlike rotary wheel heat exchangers which mix air
streams, these cross−flow or counterflow heat exchangers ensure
that there is no mixing of the stale air stream with the fresh outdoor
air stream.
A filter installed on the incoming outdoor air stream removes large
airborne particles from the intake air stream before they enter the
heat exchanger and reduces the maintenance required. The units’
acoustically engineered design make Carrier ventilators the quieteston the market and ensures that comfort is felt, not heard.
Unlatching two (2) suitcase style latches allows easy removal of the
filters and core for cleaning on most units.
NOTE: The unit should not be installed in an attic or
unconditioned space unless provisions are made for drain line
freezing and condensation.
STANDARD FEATURES
HRV
Energy saving defrost cycle
Cross−flow, counterflow heat exchangers
One filter on incoming air; one filter on outgoing air to protect core
Acoustical design
Polypropylene heat exchanger core
ERV
Integrated airflow balancing points*
Integrated furnace interlock*
High pressure blowers
Onboard control for continuous high/low ventilator operation
Energy saving defrost cycle*
Cross−flow, counterflow heat exchangers
One filter incoming air; one filter outgoing to protect core
No−tools maintenance
Enthalpic heat exchanger core
ERVCRNVA model uses EAC terminals to interlock with furnace
blower for constant ventilation
*Except ERVCRNVA
2
MODEL NUMBER NOMENCLATURE
ERV CR LHB 1 150
PRODUCT TYPE CFM
ERV - Energy Recovery Ventilator
HRV - Heat Recovery Ventilator VOLTAGE
1 - 115/60/1
BRAND - Carrier STYLE
LHB - Large Horizontal, End Ports
HRV - 150, 250 cfm
ERV - 200 cfm
SVB - Small Horizontal, Top Vertical Ports
HRV & ERV - 100 cfm
SHB - Small Horizontal, End Ports
HRV & ERV - 100 cfm
SVU - Vertical, Top Ports
HRV - 157 cfm
NVA - Narrow Vertical, Top & Side Ports
ERV - 90 cfm
These products earned the
ENERGY STAR®by meeting strict
energy efficiency guidelines set by
Natural Resources Canada and
the US EPA. They meet ENERGY
STAR requirements only when
used in Canada.
Energy Star Canada:
All units in this document meet Energy Star Tier 2
requirements in Canada except HRVCRLVU1330,
ERVCRLHB1200 and ERVCRNVA1090.
Climate Map for Energy and Heat Recovery Ventilators
ERV Recommended w/HRV or ERV Wall Control
ERV Recommended
HRV Recommended
Honolulu
Sacramento Salt Lake
City
BoiseSalem
Vancouver
Helena
Edmonton
Calgary Regina Winnipeg
Bismark
TopekaDenver
Oklahoma City
Austin
Baton Rouge
Orlando
Atlanta Columbia
Raleigh
Washington D.C.
Nashville
IndianapolisSpringfield
ChicagoDes Moines
Minneapolis
Green Bay
Milwaukee
Detroit
Madison
Harrisburg
Hartford
Boston
Syracuse
Montreal
Ottawa
Timmins
A00099
NOTE: ERVCRNVA model can only be used in Climate Zones 1 through 5. Refer to IECC Climate Zone map on Pg. 11 for use of this
model.
5
ERVCRLHB1200, HRVCRLHB1150, HRVCRLHB1250
17”
(432 mm)
17¼” (438 mm)
6”
(152 mm)
30¼” (768 mm)
35” (891 mm)
17”
(432 mm)
17¼” (438 mm)
6”
(152 mm)
34” (864 mm)
39” (991 mm)
ERV
HRV
1
2
3
4
1
2
3
4
1. Fresh air to house.
2. Exhaust air from house.
3. Fresh air from outside.
4. Exhaust air to outside.
A12341
PHYSICAL & ELECTRICAL DATA
MODEL
CAPACITY (LO-HI)PORT
LOC.
CORE WEIGHT
LBS. [KG]VOLTAGE
MAX
POWER
WATTS
MAX
AMPSCFML/S TYPE AIR FLOW
ERVCRLHB1200 80 - 198 38 - 93 Ends Enthalpic
transfer media Cross flow 76 [35]120/60/1 200 2.1
HRVCRLHB1150 66 - 163 31 - 77 Ends Polypropylene Cross flow 65 [30]120/60/1 160 1.5
HRVCRLHB1250 82 - 204 39 - 96 Ends Polypropylene Cross flow 65 [30]120/60/1 195 2.1
DEFROST OPERATION
MODEL
OUTSIDE TEMPERATURE DEFROST CYCLE (MIN.)EXTENDED DEFROST CYCLES (MIN.)
C F Defrosting
Operation Time
Between Each
Defrost Cycle
Defrosting
Operation Time
Between Each
Defrost Cycle
ERVCRLHB1200
-5 23 10 60 10 30
-15 5 10 30 10 20
-27 -17 10 20 10 15
HRVCRLHB1150
-5 23 7 50 10 30
-15 5 7 25 10 20
-27 -17 10 20 10 15
HRVCRLHB1250
-5 23 6 50 10 30
-15 5 6 25 10 20
-27 -17 10 20 10 15
6
ERVCRLHB1200, HRVCRLHB1150, HRVCRLHB1250 (cont.)
HVI RATED ENERGY PERFORMANCE
MODEL MODE
SUPPLY
TEMP
NET AIR
FLOW POWER CON
SUMED
(WATTS)
SENSIBLE RE
COVERY EF
FICIENCY
APPARENT
SENSIBLE
EFFECTIVE
NESS
LATENT
RECOVERY
MOISTURE
TRANSFER
TOTAL
RECOVERY
EFFICIENCYCFL/S CFM
ERVCRLHB1200 Heat
0 32 39 80 84 60 72 0.60
0 32 54 114 113 58 69 0.53
0 32 79 167 169 56 66 0.45
-25 -13 31 65 116 41 86 0.47
Cool 35 95 39 82 81 52
HRVCRLHB1150 Heat
0 32 31 66 67 67 79 -0.01
0 32 40 86 74 65 75 -0.01
0 32 54 115 90 61 70 -0.01
-25 -13 38 81 87 60 76 0.02
HRVCRLHB1250 Heat
0 32 39 82 71 65 75 0.01
0 32 61 130 129 60 69 0.01
-25 -13 40 84 114 60 76 0.03
VENTILATION PERFORMANCE
MODEL
EXT. STATIC
PRESSURE
NET SUPPLY AIR
FLOW
GROSS AIR FLOW
SUPPLY EXHAUST
Pa In w.g.L/S CFM L/S CFM L/S CFM
ERVCRLHB1200
25 0.1 105 222 106 225 106 225
75 0.3 93 198 94 200 100 212
100 0.4 86 183 88 186 93 198
150 0.6 70 148 71 150 75 158
200 0.8 50 107 51 108 29 61
HRVCRLHB1150
25 0.1 85 180 86 182 92 194
75 0.3 77 163 77 164 81 171
100 0.4 71 150 71 151 71 151
150 0.6 60 128 61 130 40 85
175 0.7 51 108 52 110 27 57
HRVCRLHB1250
25 0.1 106 225 107 227 118 249
75 0.3 96 204 97 205 111 235
100 0.4 90 192 91 193 107 226
150 0.6 76 161 76 162 89 189
175 0.7 67 142 67 143 75 159
NOTE: For additional data points, refer to HVI Directory at www.hvi.org
11
HEATING AND COOLING LOAD CHARTS
Although the ventilators process the outside air before it enters the home, additional heating and cooling loads need to be considered.
HEATING LOAD BTUH (APPROXIMATE)
Outside
Temperature
Heating Load (btuh) @ Inside Design Temperature 72° F (21°C)
HRV ERV
Deg. C Deg. F SVB1100 SHB1100 SVU1157 LHB1150 LHB1250 SVB1100 SHB1100 LHB1200 NVA1090
-32 -25 4778 4778 7690 6636 10603 4071 4071 8143 4071
-29 -20 4531 4531 7090 6294 10057 3861 3861 7723 3861
-26 -15 4285 4285 6520 5952 9510 3983 3983 7967 3983
-23 -10 4039 4039 5970 5610 8964 3759 3759 7509 3759
-21 -5 3800 3800 5440 5268 8417 3525 3525 7051 3525
-18 0 3410 3410 4840 4925 7871 3297 3297 6594 3297
-15 5 3095 3095 4360 4583 7324 3323 3323 6647 3323
-12 10 2795 2795 3900 4241 6777 3215 3215 6430 3215
-9 15 2465 2465 3400 3899 6231 3107 3107 6214 3107
-7 20 2195 2195 3000 3557 5684 2834 2834 5669 2834
-4 25 1935 1935 2610 3215 5138 2562 2562 5124 2562
-1 30 1680 1680 2250 2873 4591 2289 2289 4579 2289
2 35 1425 1425 1880 2531 4045 2017 2017 4034 2017
4 40 1200 1200 1560 2189 3498 1744 1744 3489 1744
COOLING LOAD BTUH (APPROXIMATE)
Outside En
thalpy
Cooling Load (btuh) @ Inside Design Temperature
72°F (21°C) and 50% Relative Humidity
HRV ERV
Btu/lb SVB1100 SHB1100 SVU1157 LHB1150 LHB1250 SVB1100 SHB1100 LHB1200 NVA1090
30 482 482 990 670 1071 320 320 640 320
31 785 785 1650 1090 1741 520 520 1040 520
32 1086 1086 2310 1509 2411 720 720 1441 720
33 1388 1388 2970 1928 3080 920 920 1841 920
34 1690 1690 3630 2347 3750 1120 1120 2241 1120
35 1992 1992 4290 2766 4419 1320 1320 2641 1320
36 2293 2293 4950 3185 5089 1520 1520 3041 1520
37 2595 2595 5610 3604 5759 1720 1720 3441 1720
38 2897 2897 6270 4023 6428 1921 1921 3842 1921
39 3198 3198 6930 4442 7098 2121 2121 4242 2121
40 3478 3478 7590 4831 7767 2321 2321 4642 2321
41 3802 3802 8250 5280 8437 2521 2521 5042 2521
42 4103 4103 8910 5699 9107 2721 2721 5442 2721
HEATING LOAD BTUH
The heating load chart shows the heating loads in Btuh for a range
of winter design temperatures for each model of ventilator.
COOLING LOAD BTUH
The cooling load chart shows loads in Btuh as well. To use the
cooling load chart, first find the design enthalpy from apsychrometric chart using the design dry bulb and wet bulb
temperatures. The cooling load can then be found for a range of
enthalpies for each ventilator.
12
Ventilator installed with forced air system
A99297
Ventilator installed with independent air distribution
A99298