Loading...
78 Maynard HVAC 3-6-20SUBMITTAL Project 78 Maynard Street Date Friday, March 6, 2020 Table Of Contents Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 2 of 13 Split System Furnace...........................................................................................................................................................3 Unit Report............................................................................................................................................................................................... 4 Performance Summary............................................................................................................................................................................. 6 System Parameters.................................................................................................................................................................................. 6 Electrical Data.......................................................................................................................................................................................... 6 Acoustic Summary ................................................................................................................................................................................... 7 Certified Drawing...................................................................................................................................................................................... 8 Unit Feature Sheet................................................................................................................................................................................. 11 Infinity Controls....................................................................................................................................................................................... 14 ERV........................................................................................................................................................................................................ 20 Note: Please confirm damper sizes. Split System Furnace Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 3 of 13 Split System Furnace Split System Furnace Submittal Cover Sheet Unit Report Performance Summary Report Acoustic Summary Certified Drawings Feature Sheet Unit Report For Split System Furnace Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 4 of 13 Unit Report Outdoor Unit Parameters Unit Model:.............................................24ANB Unit Size:................................3 Tons (Size 36) Voltage:........................................208/230-1-60 V-Ph-Hz Indoor Coil Parameters Unit Model:..............................................CNPV Unit Size:................................3 Tons (Size 36) Cabinet Finish:.....................................Painted Cabinet Width:.......................................17 inch Refrigerant Type: ....................................Puron Outdoor Unit Dimensions and Weight Unit Length:..........................................31.1875 in Unit Width: ...........................................31.1875 in Unit Height: ...................................................36 in Unit Shipping Weight:.................................275.lb Indoor Coil Dimensions and Weight Unit Length:...................................................21 in Unit Width:..................................................17.5 in Unit Height: ...................................................17 in Unit Shipping Weight:.................................48.5 lb RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and subsequent owners only to the extent and as stated in the Warranty Conditions and below. The limited warranty period in years, depending on the part and the claimant, is as shown in the table below. Limited Warranty (Years) Item Original Owner Subsequent Owner Parts 10* (or 5)5 Compressor 10* (or 5)5 *If properly registered within 90 days of original installation, otherwise 5 years (except in California and Quebec and other jurisdictions that prohibit warranty benefits conditioned on registration). See Warranty Conditions below. OTHER APPLICATIONS The warranty period is five (5) years on the compressor, and one (1) year on all other parts. The warranty is the original owner only and isnot available for subsequent owners. Ordering Information Part Number Description Quantity Outdoor Unit 24ANB736A003 Infinity Series Two-Stage Air Conditioner w/ Puron 3 Tons Cooling 1 17 SEER @ ARI Conditions Accessories SYSTXCCITC01-B Infinity Touch Wi-Fi Control for Outdoor Unit 1 SYSTXCCSMS01-B Infinity Smart Sensor for Outdoor Unit 2 Indoor Coil CNPVP3617ALA Cased Vertical N-Coil Evaporator Coil with Puron 1 Painted 17 inch Aluminum Furnace 59TN6B060C17--14 59TN6 Infinity +96 Two Stage Condensing Gas Furnace 1 +96 AFUE 60,000 Btuh (Size 060) Unit Report For Split System Furnace Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 5 of 13 Up to 1400 Clg CFM on Evap Coil Comm. Variable Speed 17.5 inches Furnace Parameters and Dimensions and Weight Furnace:SEER Enhancing Furnace Furnace Model:59TN Furnace Efficiency:+96 AFUE Htg Capacity:60,000 Btuh (Size 060) Airflow:Up to 1400 Clg CFM on Evap Coil Unit Length:29.50 in Unit Width:17.50 in Unit Height:35.00 in Unit Shipping Weight:151.lb The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Performance Summary For Split System Furnace Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 6 of 13 Performance Summary System Performance System:............................................24ANB/CNPV System Quantity:.............................................1 Altitude:........................................................0.0 ft Furnace Type:...................59TN6B060C17**14 Linear Pipe Length:....................................50.0 ft SEER @ ARI Conditions:...........................15.0 EER @ ARI Conditions:.............................12.5 Actual Clg Airflow:..................................1200.0 CFM Standard Clg Airflow: .............................1200.0 CFM Total Net Clg Capacity:............................35.29 MBH Net Sensible Clg Capacity: ......................26.10 MBH Total System Power:..................................2.79 kW System Parameters System Parameters Outdoor Unit Parameters Unit Model:..............................24ANB736A003 Unit Size (Nominal):...............3 Tons (Size 36) Voltage:........................................208/230-1-60 V-Ph-Hz Clg Ent Air DB Ambient:.............................95.0 °F Indoor Coil Parameters Unit Model:.............................CNPVP3617ALA Unit Size (Nominal):...............3 Tons (Size 36) Ent Air DB: ...............................................80.00 °F Ent Air WB:...............................................67.00 °F Ent Enthalpy:............................................31.44 BTU/lb Lvg Air DB:...............................................59.86 °F Lvg Air WB:..............................................57.80 °F Lvg Enthalpy: ...........................................24.90 BTU/lb Total External Static Pressure:...................0.20 in wg Furnace Ratings Furnace:............................59TN6B060C17--14 Furnace Efficiency:...........................+96 AFUE Furnace Efficiency ICS:..............................96.3 AFUE Input Max Heat:......................................60,000 BTU/hr Input Min Heat:.......................................39,000 BTU/hr Output Max Heat:...................................58,000 BTU/hr Output Min Heat:....................................38,000 BTU/hr Furnace Performance Certified Temp High Rise Range:.............35-65 F Certified Temp Low Rise Range: .............30-60 F The customer must ensure the specified airflow and static pressure are within furnace capabilities. Electrical Data Electrical Data Outdoor Electrical Data Unit Voltage: ................................208/230-1-60 V-Ph-Hz Fan Motor FLA:..........................................0.70 Amps MCA:..........................................................19.8 Amps Max Fuse:.....................................................35 Amps Operating Range Min:.................................197 V Operating Range Max:................................253 V Compressor RLA:.......................................15.3 Amps Compressor LRA:.......................................83.0 Amps Furnace Electrical Data Unit Voltage:........................................115-1-60 V-Ph-Hz Unit MCA:.....................................................9.3 Amps Unit MOCP:...................................................15 Amps The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Acoustic Summary For Split System Furnace Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 7 of 13 Acoustic Summary Outdoor Unit Parameters: Unit Model:...................................................................................................................................................................24ANB Unit Size:.......................................................................................................................................................3 Tons (Size 36) Variations:................................................................................................................................................................Standard Octave Band Center Frequency, Hz 125 250 500 1k 2k 4k 8k dBA Sound Power,dB 53.0 59.0 64.5 64.5 61.5 59.5 52.5 A-Weighted Sound Power, dBA 70.0 Indoor Coil Parameters: Unit Model:CNPV Unit Size:3 Tons (Size 36) Cabinet Finish:Painted Cabinet Width:17 inch No Indoor sound data available. The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Certified Drawing For Split System Furnace Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 8 of 13 CertifiedDrawing Outdoor Model Unit Model:.............................................24ANB Unit Size:................................3 Tons (Size 36) Voltage:........................................208/230-1-60 V-Ph-Hz SEER: ...........................................................17 PartNumber:............................24ANB736A003 Shipping Dimensions and Weights Outdoor Unit Height 43.38 in Width 33.31 in Length 33.31 in Operating Weight 236. lb Shipping Weight 275. lb Dimensions A B C D E F G H I J K 31.19 in 36.00 in 0.88 in 6.56 in 24.69 in 9.13 in 0.31 in 3.00 in 16.00 in 15.50 in 17.50 in The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Certified Drawing For Split System Furnace Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 9 of 13 Indoor Coil Unit Model:CNPV Unit Size:3 Tons (Size 36) Cabinet Finish:Painted Cabinet Width:17 inch PartNumber:CNPVP3617ALA Dimensions and Weights Indoor Coil Height 17.00 in Width 17.50 in Length 21.00 in Shipping Weight 48.5 lb Dimensions A B C D E F 17.00 in 13.88 in 3.56 in 15.75 in 17.50 in 0.75 in The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Certified Drawing For Split System Furnace Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 10 of 13 Furnace Model:..........................................59TN Furnace Efficiency:...........................+96 AFUE Htg Capacity: ............60,000 Btuh (Size 060) Airflow:.......Up to 1400 Clg CFM on Evap Coil PartNumber:......................59TN6B060C17--14 Dimensions A B C D Shipping Wgt 17.50 in 15.88 in 16.00 in 8.75 in 151.00 in The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29n Page 11 of 13 Unit Feature Sheet Residential Carrier Products Bldr 1.29n Page 12 of 13 Residential Carrier Products Bldr 1.29n Page 13 of 13 SYSTXCCITC01---B, SYSTXCCWIC01---B,SYSTXCCICF01---B, SYSTXCCWIF01---BInfinityrSystem Control Product Data A170203 A180218C NOTE: Infinityr System Control compatible with Infinityr rated indoor equipment only. US Patents: Carrierr U.S. Pat No. 7,243,004, Carrierr U.S. Pat No. 7,775,452, pointSETt U.S. Pat No. 7,415,102 INFINITYR SYSTEM CONTROL Carrier specializes in creating a customized home comfort system tailored to your needs with our broad selection of residential heating and cooling products. The Infinityr System Control is the ultimate control center for all of your system components. When you add an Infinityr System Control to a compatible variable speed furnace, fan coil, Infinityr System split or package unit, or small packaged product, you will enjoy longer heating and cooling cycles at lower fan speeds for a more consistent temperature throughout your home. By adding a variable speed, multi--stage, or 2--stage outdoor unit, you will enjoy extra benefits which include better humidity and temperature control as well as a more energy efficient comfort system. When paired with Infinityr Zoning controls, the Infinityr System Control allows you to create up to 8 zones of customized comfort. The Infinityr Zoning system does not require a bypass damper, leaving air temperature (LAT) sensor, or field--installed power transformer. Always install the latest version of software to enable all features of the system. Over--the--Air software updates for Wi--Fi models connected to the Infinity server are automatically downloaded. Software updates via MicroSD are available on HVACpartners, or at www.MyInfinityTouch.com. Wi --- Fir is a registered trademark of Wi---Fi Alliance Corporation.Amazon Alexa is a trademark of Amazon, Inc. or its affiliates. INDUSTRY LEADING FEATURES/BENEFITS Carrier’s revolutionary Infinityr System Control is the smart control of the future. Its unique system self--configuration and diagnostics capabilities make installation and service fast and accurate, helping to avoid costly call--backs. The Infinityr System Control features a high resolution display, making it easier to read. Intuitive prompts let you program everything from humidity levels to fan speeds, giving you the ultimate control over your home comfort. Other features include: — 4--wire installation from each major component in the system — 2--wire connection to Infinityr System two or more stage outdoor equipment (including geothermal split units) — Infinityr Zoning System compatibility — Occupancy sensing to provide comfort when spaces are occupied and energy savings when they’re not — Intuitive on screen prompts for ease of installation and service —Ideal Humidity Systemt settings are the default; no longer requiring increased system setup — Complete integration of the temperature, humidity and ventilation in every season — For Zoned Systems, auto mode selection to satisfy simultaneous heating and cooling demands in different zones via more aggressive Auto Changeover algorithm----installer must enable — 7--day programmability with Lifestyle Comfort Profiles and Touch--N--Gor features; complies with California Title 24 programmability requirements — Easy timed--override schedule — Simplified vacation schedules — Day--at--a--glance programming for simplified ease of use — Programmable fan by period — TrueSenset Dirty Filter Detection — Indoor Air Quality pop up service reminders — General maintenance reminder messaging —Wi--Firremote access capability — Upload photo, dealer info, and software updates locally via MicroSD card. Software updates available automatically when connected to the Infinity web server — Compatible with home automation through the SYSTXCCRCT01 or SYSTXCCRWF01 system access modules, or via the Côr Home Automation app or Amazon ™Alexa ™interface. — Compatible with Infinityr System geothermal products (GC and GZ models). Energy Tracking feature for geothermal systems is available with Entering Water Temperature sensor installed in heat pump. 2 MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 SYSTXCCITC01--B Product Type Version Infinityr System B Packaged Quantity Brand / Product 01 CC = Carrier XX or NN = No Brand Model Type ITC --- Black Infinityr System Control with Wi --- Fi WIC--- White Infinityr System Control with Wi --- FiICF --- Black Infinityr System Control with Wi---Fi (withFrench Literature)WIF--- White Infinityr System Control with Wi---Fi (with French Literature) A170101 Fig. 1 -- Unit Dimensions 3 PRODUCT DATA INFORMATION Compatible Communicating Products Compatible with most Infinityr System indoor and outdoor equipment built since 2004; see equipment specifications for details. Home Automation System Interface A cloud--to--cloud Open API (Application Program Interface) is available for the ITC and ITW model Infinity Touch and Infinity System Controls. See the Infinity Systems Open API Getting Started Guide available on www.HVACpartners.com or contact InfinityOpenAPI@carrier.utc.com for more information. The Infinityr System control may also connect to a variety of Home Automation systems using SAM modules. Note that not all Home Automation systems may be compatible. Reference the latest version of the Application Specification titled “SAM Remote Access Application Specification,” available on HVACpartners.com to learn more about the latest Home Automation interfaces to the Infinityr systems. Work with the home automation supplier to see if the systems are compatible. If not, you may provide the “Infinity System Open API Getting Started Guide” or the “SAM Remote Access Application Specification” to the home automation supplier to develop an interface with the Infinityr System. Always be sure to obtain the latest version of the application specification from HVACpartners, as we continually update and add home automation interfaces. NOTE: The ability to remotely access and adjust the settings of the Infinityr System Control with the MyInfinity web and mobile applications is dependent on the compatibility of the user’s computer, home network and/or mobile device, the Infinityr System Control, and/or the MyInfinity web server or other system interfaces with, and the availability of, the user’s internet service provider or mobile device carrier service. Carrier Corporation makes no representations or warranties, express or implied, including, to the extent permitted by applicable law, any implied warranty of merchantability or fitness for a particular purpose or use, about the compatibility of the user’s computer, home network, and/or mobile device, with the Infinityr System Control, and/or the MyInfinity web server or other system interfaces, with, and the availability of, the user’s internet service provider or mobile device carrier service, or that the ability to remotely access and adjust the settings of the Infinityr System Control will not be negatively affected by the network--related modifications, upgrades, or similar activity of the user’s internet service provider or mobile device carrier service. Physical Characteristics Dimensions:See drawing Appearance:Black glass front, silver plastic body Electrical Characteristics/Communication Input Volts/Amps 24VAC Each device in the Infinityr System has a four--pin connector labeled ABCD. It is recommended that the following color code be used when wiring each device: A — Green = Data A+ B — Yellow = Data B-- C — White = 24VAC (Com) D — Red = 24VAC (Hot) Always verify that the IDU and ODU are well--grounded, and that there are less than 10 volts AC/DC as measured between the cabinets of the IDU and ODU, while the equipment is operating at full capacity. If there is a larger voltage difference between the cabinets of the IDU and ODU, recheck the equipment grounding. Environmental Requirements: Operating Temperature/Relative Humidity: User interface and all sensors: 32_F to 104_F/0_Cto40_C, 95% RH non--condensing Feature Specifications: Temperature set point range: 50_Fto90_F / 10.0_C to 32.0_C Separate heat and cool setpoints Programming days: 7 day Programming periods: Up to 5 periods per day Advanced Smart Setback (with programming) Touch--N--Gor feature Occupancy Sensing Non--Programmable (installer selectable) Auto Changeover* (may be disabled) Simultaneous Heat Cool Demand Algorithm for zoned systems Programmable fan (installer selectable) Humidity Sensor Offsets Auto Changeover Timer (installer adjustable) Smart Recovery (in heating and cooling) Hold function Copy functions: copy day of week; copy zones Permanent memory Humidity display and control Temperature sensor offsets (indoor and outdoor) TrueSenset Dirty Filter Detection with compatible indoor equipment * See Installation Instructions for details on Auto Changeover and Simultaneous Heat/Cool Demand Algorithm operation. Wiring Requirements: Power supply:24VAC, 40 VA (minimum), 60 Hz, via indoor equipment ABCD Connector. Zoning systems with a large number of dampers, especially multiple dampers per zone, may require a separate, dedicated, field--installed 24VAC power supply. The SAM module requires an independent, isolated, field--supplied 24VAC power supply. Wiring material:Standard thermostat wire 18 to 22 gauge. Use 18 AWG wiring for wire lengths over 25 feet. Shielded, twisted pair cable for te ABCD communication bus is optional, and may be helpful in electrically noisy environments, or for zoning systems with Smart Sensors. NIM Requirements: IDU NON---COMMUNICATINGODU NIMREQUIRED? Furnace 1 --- stage A/C No Furnace 2 --- stage A/C Yes Furnace 1 --- stage HP Yes Furnace 2 --- stage HP Yes Fan Coil 1 --- stage A/C No Fan Coil 2 --- stage A/C Yes Fan Coil 1 --- stage HP No Fan Coil 2 --- stage HP Yes 4 CONTROLS DESCRIPTION PART NO. Infinityr System Control with Wi --- Fi r Remote Access Capability (Black)SYSTXCCITC01---B Infinityr System Control with Wi --- Fi r Remote Access Capability (White)SYSTXCCWIC01---B Infinityr System Control with Wi --- Fi r Remote Access Capability (Black with French Literature)SYSTXCCICF01---B Infinityr System Control with Wi --- Fi r Remote Access Capability (White with French Literature)SYSTXCCWIF01---B Infinityr Network Interface Module (NIM)SYSTXCCNIM01* * Required for ventilator control* Required for Hybrid Heat applications with non---communicating heat pumps* Required for use with 2---stage (non---communicating) AC or HP ZONING CONTROLS DESCRIPTION PART NO. Infinityr Damper Control Module (4 Zone)SYSTXCC4ZC01† Infinityr Smart Sensor SYSTXCCSMS01-B * NOTE: Each piece of the zoning equipment is purchased separately allowing for customization of the zoning application.**Smart Sensor dimensions are 3.375 in. (85mm) side x 4 in. (101 mm) high {One Damper Control Module for up to 4 zones. A second Damper Control Module is required for zones 5–8. OPTIONAL ACCESSORIES DESCRIPTION PART NO. Infinityr Remote Room Sensor --- Wired (RRS)SYSTXCCRRS01* Decorative Trim Plate --- Silver (six pack)SYSTXNNSBP06{ Decorative Trim Plate --- White (six pack)SYSTXNNWBP06{ Decorative Trim Plate --- Black (six pack)SYSTXNNBBP06{ Decorative Trim Plate --- Gray (six pack)SYSTXNNGBP06{ ABCD Equipment Communication Connector (Green Plug; 10 pack)SYSTXGRPLG10 Outdoor Air Temperature Sensor TSTATXXSEN01---B Energy Tracking Kit (EWT) for GC and GZ Geothermal Heat Pumps KHAGT0101KIT** Infinityr Remote Access Module, Broadband Cat---5 Wired (SAM)SYSTXCCRCT01 Accessory Power Transformer for SAM Modules**SYSTXNNXFM01** * Not required, but may be used to remote sense indoor room temperature. {Backplate dimensions 6.83 in. (173.5 mm) wide X 5.97 in. (151.7 mm) high ** Available from RC/Totaline. DAMPER ACCESSORIES & REPLACEMENT PARTS DESCRIPTION PART NO. 45º Actuator for round dampers DAMPACT45DEG-R 90º Actuator for rectangular dampers DAMPACT90DEG-R Damper Control Module 1-amp Fuse ATO1* *Available from RC. ROUND & RECTANGULAR DAMPERS DESCRIPTION PART NO. Round Dampers 6in.DAMPRND06INC-B 8in.DAMPRND08INC-B 10 in.DAMPRND10INC-B 12 in.DAMPRND12INC-B 14 in.DAMPRND14INC-B 16 in.DAMPRND16INC-B Rectangular Dampers 8in.X10in.DAMPREC08X10-B 8in.X14in.DAMPREC08X14-B 8in.X18in.DAMPREC08X18-B 8in.X24in.DAMPREC08X24-B 10 in. X 10 in.DAMPREC10X10-B 10 in. X 14 in.DAMPREC10X14-B 10 in. X 18 in.DAMPREC10X18-B 10 in. X 24 in.DAMPREC10X24-B TBD 5 SLIP--IN DAMPERS DESCRIPTION PART NO. Slip-In Dampers Side mount, 8 X 8 DAMPSLS08X08-B Bottom mount, 8 X 8 DAMPSLB08X08-B Side mount, 8 X 10 DAMPSLS08X10-B Bottom mount, 8 X 10 DAMPSLB08X10-B Side mount, 8 X 12 DAMPSLS08X12-B Bottom mount, 8 X 12 DAMPSLB08X12-B Side mount, 8 X 14 DAMPSLS08X14-B Bottom mount, 8 X 14 DAMPSLB08X14-B Side mount, 8 X 16 DAMPSLS08X16-B Bottom mount, 8 X 16 DAMPSLB08X16-B Side mount, 8 X 18 DAMPSLS08x18-B Bottom mount, 8 X 18 DAMPSLB08X18-B Side mount, 8 X 20 DAMPSLS08X20-B Bottom mount, 8 X 20 DAMPSLB08X20-B Side mount, 8 X 22 DAMPSLS08X22-B Bottom mount, 8 X 22 DAMPSLB08X22-B Side mount, 8 X 24 DAMPSLS08X24-B Bottom mount, 8 X 24 DAMPSLB08X24-B Side mount, 10 X 10 DAMPSLS10X10-B Bottom mount, 10 X 10 DAMPSLB10X10-B Side mount, 10 X 12 DAMPSLS10X12-B Bottom mount, 10 X 12 DAMPSLB10X12-B Side mount, 10 X 14 DAMPSLS10X14-B Bottom mount, 10 X 14 DAMPSLB10X14-B Side mount, 10 X 16 DAMPSLS10X16-B Bottom mount, 10 X 16 DAMPSLB10X16-B Side mount, 10 X 18 DAMPSLS10X18-B Bottom mount, 10 X18 DAMPSLB10X18-B Side mount, 10 X 20 DAMPSLS10X20-B Bottom mount, 10 X 20 DAMPSLB10X20-B Side mount, 10 X 22 DAMPSLS10X22-B Bottom mount, 10 X 22 DAMPSLB10X22-B Side mount, 10 X 24 DAMPSLS10X24-B Bottom mount, 10 X 24 DAMPSLB10X24-B Side mount, 12 X 12 DAMPSLS12X12-B Bottom mount, 12 X 12 DAMPSLB12X12-B Side mount, 12 X 14 DAMPSLS12X14-B Bottom mount, 12 X 14 DAMPSLB12X14-B Side mount, 12 X 16 DAMPSLS12X16-B Bottom mount, 12 X 16 DAMPSLB12X16-B Side mount, 12 X 18 DAMPSLS12X18-B Bottom mount, 12 X 18 DAMPSLB12X18-B Side mount, 12 X 20 DAMPSLS12X20-B Bottom mount, 12 X 20 DAMPSLB12X20-B Side mount, 14 X 14 DAMPSLS14X14-B Bottom mount, 14 X 14 DAMPSLB14X14-B Side mount, 14 X 16 DAMPSLS14X16-B Bottom mount, 14 X 16 DAMPSLB14X16-B Side mount, 14 X 20 DAMPSLS14X20-B Bottom mount, 14 X 20 DAMPSLB14X20-B Side mount, 16 X 16 DAMPSLS16X16-B Bottom mount, 16 X 16 DAMPSLB16X16-B Bottom mount, 16 X 20 DAMPSLB16X20-B TBD 6 Copyright 2019 CarrierCorp.S 7310 W. Morris St.S Indianapolis, IN 46231 . Edition Date: 07/19 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: SYSTXCCITC--05PD Replaces: SYSTXCCITC--04PD HRVCR Heat Recovery Ventilators ERVCR Energy Recovery Ventilators Product Data A05229 ERVCRSVB1100, HRVCRSVB1100 A05330ERVCRSHB1100, HRVCRSHB1100 A12338 HRVCRSVU1157 A13212ERVCRNVA A10299 ERVCRLHB1200, HRVCRLHB1150, HRVCRLHB1250 The Carrier Heat Recovery Ventilation (HRV) and Energy Recovery Ventilator (ERV) systems are the finest on the market today. These units provide efficient and cost effective heat recovery during the heating season when needed most. As temperatures drop below 23 F (−5 C), indoor air is recirculated periodically through the heat exchanger core to prevent frost from forming.* Competitors’ methods of supplementary electric defrost waste energy. Unlike rotary wheel heat exchangers which mix air streams, these cross−flow or counterflow heat exchangers ensure that there is no mixing of the stale air stream with the fresh outdoor air stream. A filter installed on the incoming outdoor air stream removes large airborne particles from the intake air stream before they enter the heat exchanger and reduces the maintenance required. The units’ acoustically engineered design make Carrier ventilators the quieteston the market and ensures that comfort is felt, not heard. Unlatching two (2) suitcase style latches allows easy removal of the filters and core for cleaning on most units. NOTE: The unit should not be installed in an attic or unconditioned space unless provisions are made for drain line freezing and condensation. STANDARD FEATURES HRV Energy saving defrost cycle Cross−flow, counterflow heat exchangers One filter on incoming air; one filter on outgoing air to protect core Acoustical design Polypropylene heat exchanger core ERV Integrated airflow balancing points* Integrated furnace interlock* High pressure blowers Onboard control for continuous high/low ventilator operation Energy saving defrost cycle* Cross−flow, counterflow heat exchangers One filter incoming air; one filter outgoing to protect core No−tools maintenance Enthalpic heat exchanger core ERVCRNVA model uses EAC terminals to interlock with furnace blower for constant ventilation *Except ERVCRNVA 2 MODEL NUMBER NOMENCLATURE ERV CR LHB 1 150 PRODUCT TYPE CFM ERV - Energy Recovery Ventilator HRV - Heat Recovery Ventilator VOLTAGE 1 - 115/60/1 BRAND - Carrier STYLE LHB - Large Horizontal, End Ports HRV - 150, 250 cfm ERV - 200 cfm SVB - Small Horizontal, Top Vertical Ports HRV & ERV - 100 cfm SHB - Small Horizontal, End Ports HRV & ERV - 100 cfm SVU - Vertical, Top Ports HRV - 157 cfm NVA - Narrow Vertical, Top & Side Ports ERV - 90 cfm These products earned the ENERGY STAR®by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA. They meet ENERGY STAR requirements only when used in Canada. Energy Star Canada: All units in this document meet Energy Star Tier 2 requirements in Canada except HRVCRLVU1330, ERVCRLHB1200 and ERVCRNVA1090. Climate Map for Energy and Heat Recovery Ventilators ERV Recommended w/HRV or ERV Wall Control ERV Recommended HRV Recommended Honolulu Sacramento Salt Lake City BoiseSalem Vancouver Helena Edmonton Calgary Regina Winnipeg Bismark TopekaDenver Oklahoma City Austin Baton Rouge Orlando Atlanta Columbia Raleigh Washington D.C. Nashville IndianapolisSpringfield ChicagoDes Moines Minneapolis Green Bay Milwaukee Detroit Madison Harrisburg Hartford Boston Syracuse Montreal Ottawa Timmins A00099 NOTE: ERVCRNVA model can only be used in Climate Zones 1 through 5. Refer to IECC Climate Zone map on Pg. 11 for use of this model. 5 ERVCRLHB1200, HRVCRLHB1150, HRVCRLHB1250 17” (432 mm) 17¼” (438 mm) 6” (152 mm) 30¼” (768 mm) 35” (891 mm) 17” (432 mm) 17¼” (438 mm) 6” (152 mm) 34” (864 mm) 39” (991 mm) ERV HRV 1 2 3 4 1 2 3 4 1. Fresh air to house. 2. Exhaust air from house. 3. Fresh air from outside. 4. Exhaust air to outside. A12341 PHYSICAL & ELECTRICAL DATA MODEL CAPACITY (LO-HI)PORT LOC. CORE WEIGHT LBS. [KG]VOLTAGE MAX POWER WATTS MAX AMPSCFML/S TYPE AIR FLOW ERVCRLHB1200 80 - 198 38 - 93 Ends Enthalpic transfer media Cross flow 76 [35]120/60/1 200 2.1 HRVCRLHB1150 66 - 163 31 - 77 Ends Polypropylene Cross flow 65 [30]120/60/1 160 1.5 HRVCRLHB1250 82 - 204 39 - 96 Ends Polypropylene Cross flow 65 [30]120/60/1 195 2.1 DEFROST OPERATION MODEL OUTSIDE TEMPERATURE DEFROST CYCLE (MIN.)EXTENDED DEFROST CYCLES (MIN.) C F Defrosting Operation Time Between Each Defrost Cycle Defrosting Operation Time Between Each Defrost Cycle ERVCRLHB1200 -5 23 10 60 10 30 -15 5 10 30 10 20 -27 -17 10 20 10 15 HRVCRLHB1150 -5 23 7 50 10 30 -15 5 7 25 10 20 -27 -17 10 20 10 15 HRVCRLHB1250 -5 23 6 50 10 30 -15 5 6 25 10 20 -27 -17 10 20 10 15 6 ERVCRLHB1200, HRVCRLHB1150, HRVCRLHB1250 (cont.) HVI RATED ENERGY PERFORMANCE MODEL MODE SUPPLY TEMP NET AIR FLOW POWER CON­ SUMED (WATTS) SENSIBLE RE­ COVERY EF­ FICIENCY APPARENT SENSIBLE EFFECTIVE­ NESS LATENT RECOVERY MOISTURE TRANSFER TOTAL RECOVERY EFFICIENCYCFL/S CFM ERVCRLHB1200 Heat 0 32 39 80 84 60 72 0.60 0 32 54 114 113 58 69 0.53 0 32 79 167 169 56 66 0.45 -25 -13 31 65 116 41 86 0.47 Cool 35 95 39 82 81 52 HRVCRLHB1150 Heat 0 32 31 66 67 67 79 -0.01 0 32 40 86 74 65 75 -0.01 0 32 54 115 90 61 70 -0.01 -25 -13 38 81 87 60 76 0.02 HRVCRLHB1250 Heat 0 32 39 82 71 65 75 0.01 0 32 61 130 129 60 69 0.01 -25 -13 40 84 114 60 76 0.03 VENTILATION PERFORMANCE MODEL EXT. STATIC PRESSURE NET SUPPLY AIR FLOW GROSS AIR FLOW SUPPLY EXHAUST Pa In w.g.L/S CFM L/S CFM L/S CFM ERVCRLHB1200 25 0.1 105 222 106 225 106 225 75 0.3 93 198 94 200 100 212 100 0.4 86 183 88 186 93 198 150 0.6 70 148 71 150 75 158 200 0.8 50 107 51 108 29 61 HRVCRLHB1150 25 0.1 85 180 86 182 92 194 75 0.3 77 163 77 164 81 171 100 0.4 71 150 71 151 71 151 150 0.6 60 128 61 130 40 85 175 0.7 51 108 52 110 27 57 HRVCRLHB1250 25 0.1 106 225 107 227 118 249 75 0.3 96 204 97 205 111 235 100 0.4 90 192 91 193 107 226 150 0.6 76 161 76 162 89 189 175 0.7 67 142 67 143 75 159 NOTE: For additional data points, refer to HVI Directory at www.hvi.org 11 HEATING AND COOLING LOAD CHARTS Although the ventilators process the outside air before it enters the home, additional heating and cooling loads need to be considered. HEATING LOAD BTUH (APPROXIMATE) Outside Temperature Heating Load (btuh) @ Inside Design Temperature 72° F (21°C) HRV ERV Deg. C Deg. F SVB1100 SHB1100 SVU1157 LHB1150 LHB1250 SVB1100 SHB1100 LHB1200 NVA1090 -32 -25 4778 4778 7690 6636 10603 4071 4071 8143 4071 -29 -20 4531 4531 7090 6294 10057 3861 3861 7723 3861 -26 -15 4285 4285 6520 5952 9510 3983 3983 7967 3983 -23 -10 4039 4039 5970 5610 8964 3759 3759 7509 3759 -21 -5 3800 3800 5440 5268 8417 3525 3525 7051 3525 -18 0 3410 3410 4840 4925 7871 3297 3297 6594 3297 -15 5 3095 3095 4360 4583 7324 3323 3323 6647 3323 -12 10 2795 2795 3900 4241 6777 3215 3215 6430 3215 -9 15 2465 2465 3400 3899 6231 3107 3107 6214 3107 -7 20 2195 2195 3000 3557 5684 2834 2834 5669 2834 -4 25 1935 1935 2610 3215 5138 2562 2562 5124 2562 -1 30 1680 1680 2250 2873 4591 2289 2289 4579 2289 2 35 1425 1425 1880 2531 4045 2017 2017 4034 2017 4 40 1200 1200 1560 2189 3498 1744 1744 3489 1744 COOLING LOAD BTUH (APPROXIMATE) Outside En­ thalpy Cooling Load (btuh) @ Inside Design Temperature 72°F (21°C) and 50% Relative Humidity HRV ERV Btu/lb SVB1100 SHB1100 SVU1157 LHB1150 LHB1250 SVB1100 SHB1100 LHB1200 NVA1090 30 482 482 990 670 1071 320 320 640 320 31 785 785 1650 1090 1741 520 520 1040 520 32 1086 1086 2310 1509 2411 720 720 1441 720 33 1388 1388 2970 1928 3080 920 920 1841 920 34 1690 1690 3630 2347 3750 1120 1120 2241 1120 35 1992 1992 4290 2766 4419 1320 1320 2641 1320 36 2293 2293 4950 3185 5089 1520 1520 3041 1520 37 2595 2595 5610 3604 5759 1720 1720 3441 1720 38 2897 2897 6270 4023 6428 1921 1921 3842 1921 39 3198 3198 6930 4442 7098 2121 2121 4242 2121 40 3478 3478 7590 4831 7767 2321 2321 4642 2321 41 3802 3802 8250 5280 8437 2521 2521 5042 2521 42 4103 4103 8910 5699 9107 2721 2721 5442 2721 HEATING LOAD BTUH The heating load chart shows the heating loads in Btuh for a range of winter design temperatures for each model of ventilator. COOLING LOAD BTUH The cooling load chart shows loads in Btuh as well. To use the cooling load chart, first find the design enthalpy from apsychrometric chart using the design dry bulb and wet bulb temperatures. The cooling load can then be found for a range of enthalpies for each ventilator. 12 Ventilator installed with forced air system A99297 Ventilator installed with independent air distribution A99298