Loading...
78 Maynard HERS HVAC PO Box 272, Turners Falls, MA 01376 Phone (413) 863-8316; Fax (413) 863-9712 www.renbuild.net Louis Hasbrouck Building Commissioner City Of Northampton 78 Maynard Street- Proposed insulation values 1. All walls on first Floor to be gutted and receive Dry – Pac Cellulose full depth of stud bay 3-3/4” from the interior with netting and smart membrane 2. Existing house second floor walls which are not being gutted to receive Dry – Pac Cellulose full depth of stud bay 3-3/4” Drilled from the exterior 3. Existing windows opening on First and second floor on West side to receive replacement windows. Weight Pockets to be filled with foam 4. Both new and existing cellar walls to receive 2-1/2” Thermax - R-18 5. Under slab in new cellar to receive 2” XPS R -10 on top of 15 Mil vapor barrier 6. New addition walls to receive Dry – Pac Cellulose full depth of stud bay 5-1/2” from the interior with netting and smart membrane. 7. Hot Roof – Underside of all new and existing rafters to receive 8” Demilec Heatlok Closed Cell Foam - R-60 includes 1” over interior face of rafter to eliminate transfer 8. Rim Joists – Both floors rafters to receive 4” Demilec Heatlok Closed Cell Foam 9.1” Polyiso R -5 over all exterior sheathing 10. U value of windows 0.28 11. All sheathing on new addition to be Zip system with tape at all seams and corners. 12. Existing board sheathing on house that remains to receive Henry Blue Skin or equal 63 Pleasant Street, Suite 300, Watertown, MA 02472 | Tel (617) 926-9300 B o s t o n L o n d o n L o s A n g e l e s N e w Y o r k   March 5, 2020       Tim Stewart  Eck | MacNeely Architects Inc. 560 Harrison Avenue Suite 403 Boston, MA 02118   Re:  78 Maynard Rd, Northampton, MA 01060  Dear Tim,    This letter is to inform you that the roof framing at the above referenced project has been designed to  accommodate the additional loading from solar panels. An allowance of 5psf was included in the design  of all roof framing to account for the possibility of solar panels being added at a future date.       Yours truly,                            Richmond So, PE                         SUBMITTAL Project 78 Maynard Street Date Friday, March 6, 2020 Table Of Contents Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 2 of 13 Split System Furnace...........................................................................................................................................................3 Unit Report............................................................................................................................................................................................... 4 Performance Summary............................................................................................................................................................................. 6 System Parameters.................................................................................................................................................................................. 6 Electrical Data.......................................................................................................................................................................................... 6 Acoustic Summary ................................................................................................................................................................................... 7 Certified Drawing...................................................................................................................................................................................... 8 Unit Feature Sheet................................................................................................................................................................................. 11 Infinity Controls....................................................................................................................................................................................... 14 ERV........................................................................................................................................................................................................ 20 Note: Please confirm damper sizes. Split System Furnace Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 3 of 13 Split System Furnace Split System Furnace Submittal Cover Sheet Unit Report Performance Summary Report Acoustic Summary Certified Drawings Feature Sheet Unit Report For Split System Furnace Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 4 of 13 Unit Report Outdoor Unit Parameters Unit Model:.............................................24ANB Unit Size:................................3 Tons (Size 36) Voltage:........................................208/230-1-60 V-Ph-Hz Indoor Coil Parameters Unit Model:..............................................CNPV Unit Size:................................3 Tons (Size 36) Cabinet Finish:.....................................Painted Cabinet Width:.......................................17 inch Refrigerant Type: ....................................Puron Outdoor Unit Dimensions and Weight Unit Length:..........................................31.1875 in Unit Width: ...........................................31.1875 in Unit Height: ...................................................36 in Unit Shipping Weight:.................................275.lb Indoor Coil Dimensions and Weight Unit Length:...................................................21 in Unit Width:..................................................17.5 in Unit Height: ...................................................17 in Unit Shipping Weight:.................................48.5 lb RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and subsequent owners only to the extent and as stated in the Warranty Conditions and below. The limited warranty period in years, depending on the part and the claimant, is as shown in the table below. Limited Warranty (Years) Item Original Owner Subsequent Owner Parts 10* (or 5)5 Compressor 10* (or 5)5 *If properly registered within 90 days of original installation, otherwise 5 years (except in California and Quebec and other jurisdictions that prohibit warranty benefits conditioned on registration). See Warranty Conditions below. OTHER APPLICATIONS The warranty period is five (5) years on the compressor, and one (1) year on all other parts. The warranty is the original owner only and isnot available for subsequent owners. Ordering Information Part Number Description Quantity Outdoor Unit 24ANB736A003 Infinity Series Two-Stage Air Conditioner w/ Puron 3 Tons Cooling 1 17 SEER @ ARI Conditions Accessories SYSTXCCITC01-B Infinity Touch Wi-Fi Control for Outdoor Unit 1 SYSTXCCSMS01-B Infinity Smart Sensor for Outdoor Unit 2 Indoor Coil CNPVP3617ALA Cased Vertical N-Coil Evaporator Coil with Puron 1 Painted 17 inch Aluminum Furnace 59TN6B060C17--14 59TN6 Infinity +96 Two Stage Condensing Gas Furnace 1 +96 AFUE 60,000 Btuh (Size 060) Unit Report For Split System Furnace Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 5 of 13 Up to 1400 Clg CFM on Evap Coil Comm. Variable Speed 17.5 inches Furnace Parameters and Dimensions and Weight Furnace:SEER Enhancing Furnace Furnace Model:59TN Furnace Efficiency:+96 AFUE Htg Capacity:60,000 Btuh (Size 060) Airflow:Up to 1400 Clg CFM on Evap Coil Unit Length:29.50 in Unit Width:17.50 in Unit Height:35.00 in Unit Shipping Weight:151.lb The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Performance Summary For Split System Furnace Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 6 of 13 Performance Summary System Performance System:............................................24ANB/CNPV System Quantity:.............................................1 Altitude:........................................................0.0 ft Furnace Type:...................59TN6B060C17**14 Linear Pipe Length:....................................50.0 ft SEER @ ARI Conditions:...........................15.0 EER @ ARI Conditions:.............................12.5 Actual Clg Airflow:..................................1200.0 CFM Standard Clg Airflow: .............................1200.0 CFM Total Net Clg Capacity:............................35.29 MBH Net Sensible Clg Capacity: ......................26.10 MBH Total System Power:..................................2.79 kW System Parameters System Parameters Outdoor Unit Parameters Unit Model:..............................24ANB736A003 Unit Size (Nominal):...............3 Tons (Size 36) Voltage:........................................208/230-1-60 V-Ph-Hz Clg Ent Air DB Ambient:.............................95.0 °F Indoor Coil Parameters Unit Model:.............................CNPVP3617ALA Unit Size (Nominal):...............3 Tons (Size 36) Ent Air DB: ...............................................80.00 °F Ent Air WB:...............................................67.00 °F Ent Enthalpy:............................................31.44 BTU/lb Lvg Air DB:...............................................59.86 °F Lvg Air WB:..............................................57.80 °F Lvg Enthalpy: ...........................................24.90 BTU/lb Total External Static Pressure:...................0.20 in wg Furnace Ratings Furnace:............................59TN6B060C17--14 Furnace Efficiency:...........................+96 AFUE Furnace Efficiency ICS:..............................96.3 AFUE Input Max Heat:......................................60,000 BTU/hr Input Min Heat:.......................................39,000 BTU/hr Output Max Heat:...................................58,000 BTU/hr Output Min Heat:....................................38,000 BTU/hr Furnace Performance Certified Temp High Rise Range:.............35-65 F Certified Temp Low Rise Range: .............30-60 F The customer must ensure the specified airflow and static pressure are within furnace capabilities. Electrical Data Electrical Data Outdoor Electrical Data Unit Voltage: ................................208/230-1-60 V-Ph-Hz Fan Motor FLA:..........................................0.70 Amps MCA:..........................................................19.8 Amps Max Fuse:.....................................................35 Amps Operating Range Min:.................................197 V Operating Range Max:................................253 V Compressor RLA:.......................................15.3 Amps Compressor LRA:.......................................83.0 Amps Furnace Electrical Data Unit Voltage:........................................115-1-60 V-Ph-Hz Unit MCA:.....................................................9.3 Amps Unit MOCP:...................................................15 Amps The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Acoustic Summary For Split System Furnace Project: 78 Maynard Street 03/06/2020 Prepared By: Residential Carrier Products Bldr 1.29n Page 7 of 13 Acoustic Summary Outdoor Unit Parameters: Unit Model:...................................................................................................................................................................24ANB Unit Size:.......................................................................................................................................................3 Tons (Size 36) Variations:................................................................................................................................................................Standard Octave Band Center Frequency, Hz 125 250 500 1k 2k 4k 8k dBA Sound Power,dB 53.0 59.0 64.5 64.5 61.5 59.5 52.5 A-Weighted Sound Power, dBA 70.0 Indoor Coil Parameters: Unit Model:CNPV Unit Size:3 Tons (Size 36) Cabinet Finish:Painted Cabinet Width:17 inch No Indoor sound data available. The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information.