Loading...
signed - Deaconess_3-19_FP-1Light Hazard•0.10gpm/ft² for 952ft² 101 7'-4½4'-84'-9Existing IDTextContent AC_WIDO_ID AC_WIDO_ID AC_WIDO_IDAC_WIDO_ID AC_WIDO_ID AC_WIDO_ID AC_WIDO_ID AC_WIDO_ID AC_WIDO_ID AC_WIDO_ID EC A4 A4 108 115 116 119 120 121 122 123 125 1-1/2x1 MT 102 103 104 105 15 2½9'-4112'-0111'-1112'-22 13'-10½1¼2'-21 12'-11 1½ 8'-5 1 8'-5 7'-06'-0 11'-016'-219'-019'-5½112'-012'-119'-3112'-0109 110 112 110'-60'-48 61 2 3 4 2½45 Hydraulic Information OCCUPANCY CLASSIFICATION Light Hazard DENSITY (gpm/ft²)0.10 for 1500ft² (Actual 952ft²) QUICK RESPONSE REDUCTION 10'-0 Ceiling (40.0%) 900ft² TOTAL HOSE STREAMS 100.00 DRY CAPACITY 0.00gal TOTAL HEADS FLOWING 9 K-FACTOR 5.6 TOTAL WATER REQUIRED 275.98 TOTAL PRESSURE REQUIRED 59.906 BASE of RISER (gpm)175.98 BASE of RISER (psi)59.873 SAFETY MARGIN (psi)+25.852 (30.1%)Deaconess3-18.cad PRINTED ON 03/19/24 AT 14:30:161 FLOOR PLAN SCALE: 1/4" = 1'-0 Deaconess RockridgeNTS SITE MAP2 EXISTING SYSTEM RISER - DIAGRAMMATIC NTS3 FLEX HOSE TO BE VICTAULIC VICFLEX AH2 SERIES. HYDRAULIC CALCULATIONS ASSUME THAT ALL FLEX HOSES ARE 72" LENGTH, 1/2" OUTLET WITH EQUIVALENT LENGTH OF 55'-0". NTS4INSTALLATION DETAILS REVISIONSSheet 1 of 1 Seal North Sheet TitleNODATEProject Name and AddressDrawing Date: Scale: Drawn By: Contractor:PERMIT DRAWING1GENERAL NOTES SITE PLANS & DETAILS & FLOOR PLANNorthampton, MaFP-125-37 Coles Meadow Rd03-19-24413-589-0672Ludlow, MA 01056 MA. LICENSE NO: SC-148712 MA. EXP: 4-21-25 CT. LICENSE NO: FRP.0041560-F1 CT. EXP: 10-31-24 533 Center Street - PO Box 582 THESE CONSTRUCTION DOCUMENTS HAVE BEEN DESIGNED BY IMPACT FIRE SERVICES, INC. A MASSACHUSETTS LICENSED SPRINKLER CONTRACTOR (LIC. # SC-148712) FOR INSTALLATION BY IMPACT FIRE SERVICES, INC., AND ALTHOUGH STAMPED BY A PROFESSIONAL ENGINEER, OWNERSHIP AND USE OF THESE DRAWINGS AND DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND SHALL REMAIN PROPERTY OF IMPACT FIRE SERVICES, INC. THESE DOCUMENTS ARE NOT TO BE USED IN WHOLE OR PART FOR ANY OTHER PROJECTS, BUILDINGS, OR PURPOSES, OR BY ANY PARTIES OTHER THAN THOSE PROPERLY AUTHORIZED BY CONTRACT WITHOUT THE EXPRESS WRITTEN AUTHORIZATION OF IMPACT FIRE SERVICES, INC. 03-19-2024 CD Impact Fire 1/4" = 1'-0"IMPACT JOB #: 117-332808124' 2' 10'12'8' 6' 6'12'10'6' 4' 2'2' 1/4"=1'-0" GRAPHICAL SCALE REPRESENTATION 4'0' 0' 8'1/8"=1'-0" VICFLEX AH2 BAIDED HOSE EQUIVALENT LENGTH DESIGN GUIDE BRANCHLINE 1" ELL 1" NIPPLE ACT CEILING PENDENT W/ COVER PLATE 1" ELL 1" DROP TYP. RETURN BEND ASSEMBLY WITH VICTAULIC AH2 FLEXHOSE ALL FLEX HOSES ARE 72" LENGTH 1/2" OUTLET WITH AN EQUIVALENT LENGTH OF 55'-0"HYDRAULIC CALCULATIONS ASSUME MAXIMUM HYDRAULIC LOSS TOP BEAM CLAMP 1/2" A.T.R. FOR 6"-8" PIPE3/8" A.T.R. FOR 1"-4" PIPE HANGER RING PERMIT DRAWINGGAUGED HYDRANT +0 ELE FLOW HYDRANT +0 ELE 6" AREA OF SCOPE 1354 SQ FT +0 ELEV UNABLE TO GET UP TO DATE FLOW TEST DUE TO COLD SEASON 8" 4" 2.5" TO TENANT SPACE BASE OF RISER 4" DCVA 4" 4" 6" 0.10 GPM/FT² OVER 1500 FT² WITH A 100 GPM HOSE STREAM PER AREA / DENSITY METHOD PER NFPA 13 11.2.3.2. 40% QR REDUCTION TO 900 FT² APPLIES PER NFPA-13 SECTION 11.2.3.2.3. 952 ACTUAL FT² HYDRAULICALLY CALCULATED WITH REDUCTION. Sprinkler Legend Symbol Manufacturer SIN Model Quantity K-Factor Type Size Response Finish Temperature Note Generic 11 5.6 Pendent ½Quick Chrome 200°F DEMO Victaulic V2708 FL-QR 14 5.6 Pendent ½Quick Chrome 200°F New Recessed Pendent Total = 25 4" 3.DENSITY/AREA: CONDUCTED BY: 58 LOCATION: STATIC: IMPACT FIRE SERVICES COEFF: DPW 87 25 COLES MEADOW RD ORIFICE: 1:00 PM RESIDUAL: 0 PSI 0.9 ELEVATION: INCH NORTHAMPTON, MA WITNESSED BY: GPM PITOT: TEST DATE: FLOW:720 7/19/2016 52 2.5 PSI FT PSI WATER FLOW INFORMATION TEST TIME: 7. PENDENT SPRINKLERS ARE TO BE INSTALLED VISUALLY STRAIGHT AND ARE TO BE LOCATED IN THE CENTER OF THE CEILING 15. DENOTES HYDRAULIC REFERENCE POINTS. 4. OCCUPANCY: GENERAL NOTES: 17. SPRINKLER HEAD DEFLECTOR DISTANCE 1"-6" MAXIMUM BELOW STRUCTURAL MEMBER NOT TO EXCEED 22" BELOW THE DECK 4. PIPING TO BE SUPPORTED AS REQUIRED BY NFPA-13. HANGERS ARE TO BE FIELD LOCATED TO BEST SUPPORT THE PIPE. WELDED OUTLETS OR FIELD INSTALLED MECHANICAL TEES AND GROOVED ENDS AND FITTINGS. ALL NEW PIPING TO BE SIZED THE SPRINKLER SYSTEM FOR THIS RETROFIT PROJECT IS AN EXISTING WET SYSTEM. THE PIPE SIZING AND SPACING OF THE 5. STRUCTURAL LOAD BEARING ANALYSIS OF THE FIRE SPRINKLER SYSTEM AND IT'S RELATED COMPONENTS HAVE NOT BEEN 5. HYDRAULIC NOTE: EXISTING SYSTEM PIPE SIZING. EXISTING SPACE IS FED BY 1 ZONE TO FEED TENANT SPACE IN ENTIRETY 14. THERE IS TO BE NO STORAGE IN CORRIDORS. CORRIDORS ARE LIGHT HAZARD ONLY. PER THE EXISTING SYSTEM PIPE SIZING. 13. OWNER TO MAINTAIN 18" OF CLEARANCE FROM SPRINKLER DEFLECTOR TO TOP OF PENDENT LIGHT FIXTURES & STORAGE. WITH THE EXISTING BUILDING'S ESTABLISHED PIPE SIZING SCHEDULE. 3. BRANCHLINE PIPING: SECTION 6.2.1.1. 18. MANUFACTURER'S TECHNICAL DATA SHEET PARAMETERS WILL BE FOLLOWED. SYSTEM NOTES: TILES ± 1". 8. ALL SPRINKLERS RELOCATED FROM EXISTING OUTLETS TO HAVE NEW SPRINKLER HEADS INSTALLED PER NFPA-13 2013, NON-COMBUSTIBLE 9. ALL EXISTING PIPE AND HEAD LOCATIONS ARE APPROXIMATE. INSTALLER TO VERIFY LOCATION OF EXISTING OUTLETS IN FIELD. REUSE AND RAISE EXISTING MAIN TO CONFORM WITH TENANT VERTICAL CLEARANCE REQUIREMENTS 3.2. NEW AND EXISTING WET SYSTEM BRANCHLINE PIPING 1-1/4" & SMALLER, ARMOVERS, AND DROPS/SPRIGS TO NEW 2.1. NEW AND EXISTING WET SYSTEM MAIN PIPING 1-1/2" & LARGER TO BE SCHEDULE 10 BLACK PIPE WITH SHOP WELDED OTHER MECHANICAL TRADE INSTALLATIONS AND AS PART OF THE BUILDING EXPANSION, HAVE BEEN SIZED IN ACCORDANCE 6. OWNER IS REQUIRED TO PROVIDE HEAT THROUGHOUT THE ENTIRE BUILDING TO MAINTAIN A MINIMUM TEMPERATURE OF 40° OUTLETS OR FIELD INSTALLED MECHANICAL TEES AND GROOVED ENDS AND FITTINGS. ALL NEW PIPING TO BE SIZED PER THE NFPA-13 2013 CRITERIA FOR LIGHT HAZARD AND ORDINARY HAZARD SPACING RESPECTIVELY. FAHRENHEIT FOR ALL AREAS PROTECTED WITH A WET PIPE SPRINKLER SYSTEM. THE SYSTEM IS TO BE MAINTAINED BY THE SPRINKLERS TO BE SCHEDULE 40 BLACK PIPE WITH THREADED ENDS AND BLACK FITTINGS. ALL NEW PIPING TO BE SIZED PER THE OWNER AS REQUIRED BY NFPA-25. 2. MAIN PIPING: 1. SCOPE: 3.1. NEW AND EXISTING WET SYSTEM BRANCHLINE PIPING 1-1/2" & LARGER TO BE SCHEDULE 10 BLACK PIPE WITH SHOP 1. SYSTEM INSTALLATION TO CONFORM TO NFPA-13, 2013 EDITION. 2. BUILDING CONSTRUCTION: INCLUDED AS PART OF THIS CONTRACT. RELOCATED SPRINKLERS SHALL REMAIN CONSISTENT WITH THE EXISTING LAYOUT AND PIPE-SIZING SCHEDULE ALREADY 11. ALL NEW HEADS TO MATCH EXISTING. INSTALLER TO VERIFY IN FIELD. DETERMINED AND INSTALLED IN THE EXISTING BUILDING. SPRINKLER SPACING HAS BEEN MAINTAINED IN ACCORDANCE WITH FOR OBSTRUCTED CONSTRUCTION. 16. SPRINKLER HEAD DEFLECTOR DISTANCE 1"-12" MAXIMUM BELOW THE DECK FOR UNOBSTRUCTED CONSTRUCTION. PROVIDE PENDENT PROTECTION IN ALL FINISHED CEILING AREAS. CONNECT TO EXISTING LINES WITH FLEXIBLE BRAIDED HOSES. 12. SMALL ROOM RULE IN USE WHERE APPLICABLE. ANY NEW PIPING INSTALLED AS A RESULT OF PIPING RELOCATIONS TO ACCOMMODATE THE NEW ARCHITECTURAL LAYOUT OR 10. NEW PIPE DIMENSIONS ARE APPROXIMATE. INSTALLER TO VERIFY PIPE LENGTH IN FIELD. EXISTING SYSTEM PIPE SIZING. RESIDENTIAL ASSISTED LIVING AREA - OUT OF SCOPE ASSEMBLY - RECREATION AREA (LIGHT HAZARD) - IN SCOPE 4 1 2 3 4