Loading...
49-047 BP-2024-0135 773 PARK HILL RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 49-047-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit # BP-2024-0135 PERMISSION IS HEREBY GRANTED TO: Project# 2024 SOLAR Contractor: License: NORTHEAST SOLAR DESIGN Est. Cost: 37645 ASSOCIATES LLC 106113 Const.Class: Exp.Date: 06/07/2025 Use Group: Owner: SILLETTO, JOHN& RABSON, BARBRA Lot Size (sq.ft.) Zoning: WP/WSP Applicant: NORTHEAST SOLAR DESIGN ASSOCIATES LLC Applicant Address Phone: Insurance: 136 Elm St 4132476045 202300019843 HATFIELD, MA 01038 ISSUED ON: 02/09/2024 TO PERFORM THE FOLLOWING WORK: INSTALL 31 PANEL 12.555 KW ROOF MOUNT SOLAR SYSTEM (NO STRUCTURAL OR BATTERY) POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: (611,etkAk., . 551/ • Fees Paid: $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner DocuSign Envelope ID:249FBC5D-9359-424F-96F2-7DF611DD3329 l 1�d,�y V 1' The Commonwealth of Massachiiset i' GF�'� Board of Building Regulations and S tan , rd 'EB FOR 8 2024 MIJNICIPALITY Massachusetts State Building Code,/780 tMR',� USE Building Permit Application To Construct, Repair/Rei , h...a.....� Revised Mar 2011 '1ORTHAMn7 4'ItdSPECTIONS One- or Two-Family Dwelling — o, .MA0,c; This Section For Official Use Only Building Permit Number: .?9 / .A.. Date Applied: /4-VIO K beoss ///' 2- 8-z zy Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map & Parcel Numbers 773 Park Hill Rd 1.1a Is this an accepted street?yes X no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private CIZone: _ Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: John Silletto Northampton MA 01060 Name(Print) City, State,ZIP 773 Park Hill Rd 1-857-373-9464 John.G.Silletto@alum.mit.edu No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) ❑ Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units Other gi Specify: Solar Brief Description of Proposed Work'`: Install 31 solar panels on Roof SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1. Building $ 1. Building Permit Fee: $ Indicate how fee is determined: ❑ Standard City/Town Application Fee 2. Electrical $ . ❑ Total Project Cost3 (Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5. Mechanical (Fire $ Suppression) Total All Fees: Check No.9,3 Wed(Atnoun . 1 Cash Amount: 6. Total Project Cost: $ $37,645 0 Paid in Full 0 Outstanding Balance Due: DocuSign Envelope ID:249FBC5D-9359-424F-96F2-7DF611 DD3329 SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-106113 6/7/25 Phillip Baunsgard License Number Expiration Date Name of CSL Holder 41 Heath Rd List CSL Type(see below) U No. and Street Type Description Colrain, Ma 01340 U Unrestricted(Buildings up to 35,000 cu. ft.) R Restricted 1&2 Family Dwelling City/ n, State,ZIP/ M Masonry RC Roofing Covering • WS Window and Siding SF Solid Fuel Burning Appliances 413-247-6045 phil northeast-solar.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 169641 7/13/25 Northeast Solar HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 136 Elm St. Permitting@northeast-solar.com No.and Street Email address Hatfield, Ma. 01038 413-247-6045 City/Town, State,ZIP Telephone SECTION 6: WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L. c. 152. § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes No ❑ SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Northeast Solar to act on my behalf, in all matters relative to work authorized by this building permit application. '—°°`arled°' 10/24/2023 jotuA.Sado 411111111 Mink. -. Print Owner's Name Yec i nkc Signature) Date SECTION 7b: OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below, I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledg and understanding. 'gVSbG � � rod /tail Print Owner's or Authori Agent's Name(Ele tronic Signature Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L. c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq. ft.) (including garage, finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" DocuSign Envelope ID:249FBC5D-9359-424F-96F2-7DF611 DD3329 City of Northampton a�i o •' Massachusetts 4 � s 16 ,41A DEPARTMENT OF BUILDING INSPECTIONS M' 212 Main Street • Municipal Building „ a� Northampton, NA 01060 °'syw CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40, S54, a condition of Building Permit Number is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A. The debris will be disposed of in: Northeast Solar Dumpster 136 Elm St, Hatfield Ma 01038 Location of Facility: The debris will be transported by: Northeast Solar Crew Name of Hauler: USA Recycling Hauls NES Dumpster � ( /2 4 • 10/24/2023 Signature of Applicant: '' Date: __ The Commonwealth of Massachusetts . Il Department of Industrial Accidents `` _ i., y. Office of Investigations E- i''i^r 1 congress Street, Suite 100 Fr Boston, MA 02114-2017 T�:� f . v.mass.gov/dia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print Legibly Business/Organization Name: Northeast Solar Address:136 Elm St. City/State/Zip:Hatfield, Ma 01038 phone#:413-247-6045 Are you an employer? Check the app rop riate box: Business Type(requited): 1.0 I am a employer with 26 employees(full and/ 5. ❑Retail or part-time).* 6. ❑RestaurantiBar/EatingEstablishmant 2.0 I am a sole proprietor or partnership and have no 7. El Office arixi/orSales(incl. real estate, auto, etc.) employees working for m e in any capacity. [No workers' comp.insurance required] 8. El Non-profit 3.0 We are a corporation and its officers have exercised 9. ❑Entertainment their right of exemption per c. 152,§1(4), and we have 10.0 Manufacturing no employees. [No workers' comp. insurance requared]*4 4.0 We are a non-profit or ganiz ati on, staffed by volunteers, 11.0Healthcare with no employees. [No workers' comp. insurance req.] 12.123 Other Solar Panels *Any applicant that clacks box#1 nust also fill cut the sectionbelvv sharing their workers'compensation policy information. **If the curptaate officers have exempted themselves,but tie corforation has otherempio'es,awonkers'compensation pnliryis sequined and such an oaganization should check box#1. I am an employer that is providing'workers'compensation insurance for my employees. Below is the policy information. Insurance Company Name:National Casualty Company Insurer's Address: 773 Park Hill Rd CityYState/zip: Northampton MA 01060 P olicy# or S elf-ins.Lic... 20230019843 Expiration Date: 7/8/2024 Attach a copy of the workers' comp ensatio n p o licy declaration page(showing the p olicy number and exp iratio n date). Failure to secure coverage as required under Section25A ofMGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP 'MDRK ORDER and a fine of up to$250.00 a day ay,nst the vio - •r. B..advised that a copy of this statement may be forwarded to the Office of Investigations of the DI . o insur . er • verification. I do hereby ce ; y pa of perjury that the information provided above is true and correct. gn t Signature: � 0,i r D ate: 10/24/2023 Phone#:413-247-6045 Official use only. Do not write in this area, to be completed by city or town official City or Town: PermitiLicense # Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4.Licensing Board 5. Selectmen's Office 6. Other Contact Person: Phone#: wviw.may s gov/dia Client#: 169764 NORTSOL ACORD„ CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDIYYYY)7/10/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTNAME: Commercial Commercial Support Edgewood Partners Ins. Center PHONE 781 455-0700 FAX (NC,No,Ext): (ac,No): 144 Gould Street,Suite 100 E-MAIL NEcertificates a icbrokers.com ADDRESS: P Needham,MA 02494 INSURER(S)AFFORDING COVERAGE NAIC# 781 455-0700 INSURER A:Gotham Insurance Company 25569 INSURED INSURER B:National Casualty Company 11991 Northeast Solar Design Associates,LLC INSURER C:Safety First Insurance Company 11123 136 Elm Street INSURER D: Hatfield,MA 01038 INSURERE: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE INSRL SUBR WVD POLICY NUMBER POLICY EFF POLICY EXP UNITS _ {MMIDDIYYYY) (MMIDDIYYYY) A X COMMERCIAL GENERAL LIABILITY 202300025855 07/08/2023 07/08/2024 EACH OCCURRENCE $1,000,000 CLAIMS-MADE X OCCUR PREMISES(EaEnN'irrrrence) $500,000 X BI/PD Ded:5,000 MED EXP(Any one person) $5,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 PRO- POLICY X JECT LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ C AUTOMOBILE LIABILITY 5909629 07/08/2023 07/08/2024 Ea aEcccidenntSINGLE LIMIT $1,000,000 ANY AUTO BODILY INJURY(Per person) $ AUTOS ONLY X SCHEDULED AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE $ X AUTOS ONLY X AUTOS ONLY (Per accident) $ A UMBRELLA UAB X OCCUR XS22030004 07/08/2023 07/08/2024 EACH OCCURRENCE $1,000,000 X EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ _ $ B WORKERS COMPENSATION 20230019843 07/08/2023 07/08/2024 X STATUTE ERA AND EMPLOYERS'LIABILITY Y/N - ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N N I A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Issued as Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION Cityof Northampton SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE P THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 210 North Main Street ACCORDANCE WITH THE POLICY PROVISIONS. Northampton, MA 01060 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD #55765155/M5763194 RH002 Commonwealth of Massachusetts Division of Occupational Licensure Board of Building Reg44tations and Standards COftlta►WSg rvisor CS-106113 E1ltpires:06/07/2025 PHILL.IP BA r 41 HEATH COLRAIN MAtO1 f { 14, 1.3 Commissioner d ga THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washingtcll atrf t- Suite 710 Boston, Massachusetts 0118 Home Improvement Contractor Registration Type: LLC Registration: 169641 NORTHEAST SOLAR DESIGN ASSOCIATES,1te Ertpiration: 07/13/2025 136 ELM ST HATFIELD, MA 01038 Update Address and Return Card. THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs&Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE:LLC Office of Consumer Affairs and Business Regulation Reet5tratiop Emir/atop 1000 Washingtgn Street -Suite/710 169641 01/14/2025 Boston,MA 021141\ NORTHEAST SOLAR DESIGN ASSOCIATES LLC I GREGORY GARRISON 1 I 1 X�-- I36 ELM ST ' ,� ; aesoh J - HA'HELD MA 01038 , y. Undersecretary Not-valdout signature :I '�`;P. „� te a # r w T v , iqk - _ • ////ITT `Z } • • k .y , - 7 [ � •} A � x'lI'4 1sL., ..1 - 13ly! ss. l , , . Wye_y S: . " f 'i l .-rIF' F f _ II' `4j ; yk T W'S0 _7 _Y tO ., Roof mounted solar array with -°� 6 ' -, �, OP 31x REC modules and ' . .- 31 x Enphase IQ8Plus-72-2-US F t jf. �' - .•t,..� microinverters `, _ _ �q . , 1.;r i . y''•r'- 4110, ... A i } g , -' = st f ,Y , 417,41b‘ 7-* .. , . ft C r 4 , Y a (. 4... btle.! ti 6 ' iikiiitt: -' Silletto - 773 Park Hill Rd _ ' NORTHEAST Northampton SOL A R INDEPENDENCE Vreeland Design Associates An integrative approach to design engineering and site planning Date: February 5, 2024 To: Justin Annis Northeast Solar 136 Elm Street Hatfield, MA 01038 From: David Vreeland, P.E. Vreeland Design Associates Re: John Silletto, 773 Park Hill Road,Northampton, MA: Structural assessment of existing house and garage roofs to support proposed PV solar panel arrays. I have reviewed the house construction plans, the garage roof truss plans and investigated the roof framing for the proposed PV solar panel installations. The 1-1/2-story, 27'-8"x 48' cape style house with 24'x 24' garage was constructed in 2023.23 PV solar panels are to be installed on the front south facing roof of the house and 8 solar panels on the south facing roof of the garage. The house is a modular manufactured construction with the roof framed with 2x8 rafters installed 16" on-center, spanning 9'-6"with a 10/12 roof slope. Short 2x6 rafters are attached to the upper ends of the 2x8 rafters and span the 4' distance to the ridge.2x6 ceiling joists are nailed to the sides of the 2x8 rafters just below the connection to the short 2x6 rafters. 2x4 kneewalls, located 6' in from the exterior walls, are supported on the 2"d floor 2x10 floor joists that are installed 16"on-center and are support on a double 2x4 marriage wall or hung on the side of a 4—20"LVL beam that spans a 22' opening.The attached garage roof is framed with Attic Storage trusses, designed and manufactured by UFP Belchertown, LLC, installed 24"on-center, spanning 24' with a 10/12 roof pitch. The trusses have been designed for a 35 psf roof snow load, a 15 psf dead load on the top chord, and a 117 mph Vo basic wind speed. The roofing is composite asphalt shingles. I have reviewed the mounting details for the proposed PV solar panel array. Based on my calculations and a PV solar panel unit weight of 46± lbs, with the attachment points of the array placed at a maximum of 4' on center and staggered to minimize the load to any one rafter or roof truss,the existing house and garage roof framing are adequate to support the proposed PV solar panels and the 40 psf ground and 35 psf snow load and the 117 mph V„u basic wind speed requirements of the current 9th Edition of the MA State Building Code for the City of Northampton. Please contact me if you have any questions or need additional information. �HOFMA Sincerely, �P� ssq = DAVID A. y � c �} VREELAND o CIVIL " No. 46317 " David Vreeland, PE 1 ,ks-it% Vreeland Design Associates �Fess/ONALt-NG�� 116 River Road, Leyden, MA 01337 Phone: (413) 624-0126 Email: dvreeland@verizon.net Fax: (413) 624-3282 4 Roof Area N " Garage_ F House Roofs Sq Ft 1,240H______ ouse Roofs Sq Ft 1,900 Total Roof Sq Ft 3,140 GARAGE Array Area Solar Module Sq Ft 19.9 i8" Array Sq Ft 616.9 HOUSE Array Roof Coverage 19.6% 36" Required Ridge Setback 18" gigning. 36 System Details Ill II : System Size 31 panels El Street & Roof Pitch 40° i Driveway Access 1 Roofing Material i Asphalt Shingle Slllettoelf 773 Park Hill Rd Northampton NORTHEAST SOLAR INDEPENDENCE SOLAR'S MOST TRUSTED R EC FIRE ,41141: mem.) pR-iro 1T -,DEr-- f,•-; • , -• , • . EXPERIENCE REC. 405 WP 25 YEAR *4611' 20 3 /F-12 VvAkRAN LEAD-FREE ELIGIBLE ROHS COMPLIANT PERFORMANCE • • - - . • . 1 • • - ••• ' •L: • ; : 1 .. • REC PRODUCT SPECIFICATIONS SOLAR'S MOST TRUSTED REC ALPHA PURE SERIES>PK.:J:F SPECI-L". �"•li 1821±2.5(71.7±0.11 _, _-_ _„ CERTIFICATIONS_ '�28[t.1] 901[35.51 IEC61215:2016,1EC61730:2016,UL61730 460[78.1] A ", j # IEC62804 PID - 1 s3.7[6.os1 1- 1 IEC 61701 Salt Mist 1100[43.3] I� j IEC 62716 Ammonia Resistance , UL61730 Fire TypeClass2 6.o±0 2 1EC 62782 Dynamic Mechanical Load _ (0.24±0.01] +� IEC 61215-2:2016 Hailstone(35mm) 0 o m IEC 62321 Lead-freeacc.toRoHSEU863/2015 ,e1 3 __-� N 15014001:2004,ISO9001:2015,OH5A518001:20071EC62941 4.1 .11[0.43±0.01) .O - - Mxrtek Lead-cree =r.: WARRANTY 20.5±0.5 ' i ��s 1 zoo[47.z] - oi Standard REC ProTrust 153.7[6.05] Installed by an REC Certified y. t . t Solar Professional No Yes Yes ,t _. ,( -t--45[1.81 22.5[0.91 _ 671±3[26.4±0.121 System Size All 425 kW 25-500 kW I - - '30[1.21 Product Warranty(yrs) 20 25 25 Measurements in mm[in] A Power Warranty(yrs) 25 25 25 10 GENERAL DATA Labor Warranty(yrs) 0 25 10 132half-cutRECheterojunctioncells StaubliMC4PV-KBT4/KST4,12AWG(4mm°) Power in Year] 98% 98% 98% Cell type: withiead-free,gaplesstechnology Connectors: in accordance with IEC62852 Annual Degradation 0.25% 0.25% 0.25% 6stringsof22 cells inseries IP68 only when connected Power in Year 25 92% 92% 92% See warranty documents for details.Conditions apply 013in(3.2mm)solar glasswith 12AWG(4mm2)PV wire,43+47 in(1.1+1.2m) Glass: Cable:anti reflection surface treatment accordance with EN50618 "MAXIMUM RATINGS Backsheet: Highly resistantpolymer(black) Dimensions: 71.7 x 40 x1.2 in(1821 x1016 x 30 mm) Operational temperature: 40...+185°F(-40.., 85°C) P P +85°C) ., Frame: Anodized aluminum(black) Weight: 45 Ibs(20.S kg) Maximum system voltage: 1000 V .2 3 3-part 3bypassdiodes,IP68rated Maximum test toad(front): +7000Pa(1461bs/sgft)' Junction box: n accordance with lEC62790 Ongin: Made in Singapore Maximum test load(rear): -4000Pa(83.51bs/sgft)' m Max series fuse rating: 25 A ELECTRICAL DATA Product Code':RECxxxAA Pure g "" -,..`""" Max reverse current: 25 A Power Output-P.(Wp) 385 390 395 400 405 'See installation manual for mounting instructions. I Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+5 0/+5 Design load-Test load/1.5(safety factor) r. Nominal Power Voltage-VMPP(V) 41.2 41.5 41.8 42.1 42.4 TEMPERATURE RATINGS* _2 F Nominal Power Current 9.35 9.40 9.45 9.51 9.56 Nominal Module Operating Temperature: 44°C(±2°C) a cn Open Circuit Voltage-Vac(V) 48.5 48.6 48.7 48.8 48.9 Temperature coefficient ofPMAx: -0.26%/°C Short Circuit Current-Isc(A) 10.18 10.19 10.20 10.25 10.30 Temperature coefficient of Vac: -0.24%/°C Power Density(W/sq ft) 19.3 19.6 19.8 20.1 20.3 Temperature coefficient of lsc: 0.04%/°C Panel Efficiency(%) 20.8 21.1 21.3 21.6 21.9 'The temperature coefficients stated are]inearvalues LOW LIGHT BEHAVIOUR Power Output-PMA0(Wp) 293 297 301 305 309 Typical low Irradiance performance of module at STC: v F Nominal Power Voltage-VMPP(V) 38.8 39.1 39.4 39.7 40.0 g Nominal Power Currentt-IMPP(A) 7.55 7.59 7.63 7.68 7.72 e o Z N Open Circuit Voltage-Vac(V) 45.7 45,8 45.9 46.0 46.1 --- o Short Circuit Current Isc(A) 8.16 8.20 8.24 8.28 8.32 w ° it Valuesatstandardtestconditions(STC:airmassAMI.5,irradiance10.75W/sgit(1000W/m5,temperature77°F(25°C),basedonaproduction ce _ , spread with a tolerance of P„Ax,Va&lut3%withinonewattclass.Nominalmoduleoperatingtemperature(NMOT:airmassAMI.S.irradiance - Irradfance(W/m'). 800 W/m'.temperature 68°F(20°C),windspeed 3.3 ft/s(1 m/s).*Where xxx indicates the nominal power class(P,Ax)at STC above. Founded in 1996,REC Group is an international pioneering solar energy le) REC C company dedicated to empowering consumers with clean,affordable "` solar power.As Solar's Most Trusted,REC is committed to high quality, innovation,and a low carbon footprint in the solar materials and solar wwwrecgroup.com panels it manufactures. Headquartered in Norway with operational a' '.)] headquarters in Singapore,REC also has regional hubs in North America, ',...+ Europe.and Asia-Pacific. f. //r IRONRIDGE XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless f -' ,t extreme weather events. Not just the worst storms in years, �1 / .,2‘7 but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing `' , enough to buckle a panel frame. { 1t.":-*:, -.11,,s,,,,.:"fi XR Rails are the structural backbone preventing ,• .� - these results. They resist uplift, protect '� ' against buckling and safely and efficiently transfer loads into the building structure. ` . t Their superior spanning capability vslR requires fewer roof attachments, f reducing the number of roof penetrations and the amount + of installation time. 4. r Irv. 431 . i„ 5 °1,,,,,*".74:::tit::,4'.',*;',':',,,,,::,,,!-::''' y Force-Stabilizing Curve 2'°mo ° Sloped roofs generate both vertical and lateral ` k *t, r f w ,, , x forces on mounting rails which can cause them " ? . ' ,, to bend and twist.The curved shape of XR Rails „r � ' � e► " 1 is specially designed to increase strength in both t r �*r x directions while resistingthe twistin This unique 9- Q v -�,,, fin'.; feature ensures greater security during extreme r h a � r� weather and a longer system lifetime. 4 s . Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials XR Rails are IronRidge offers All XR Rails are made of 6000 series �, compatible with a range of tilt leg aluminum alloy,then protected with an FlashFoot and n options for fiat anodized finish.Anodizing prevents surface f ` other pitched roof f i roof mounting and structural corrosion,while also providing attachments. applications. a more attractive appearance. *, .. s ee^ryr :,v, ew u" �y,Y it; x e a"` "' y, � .S�rvr ' T as o. e-„ n+ ' 7 « aJ-, Tech Brief XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. • 6'spanning capability • 10'spanning capability • 12'spanning capability • Moderate load capability • Heavy load capability • Extreme load capability • Clear&black anodized finish • Clear&black anodized finish • Clear anodized finish • Internal splices available • Internal splices available • Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load Rail Span Snow(PSF) Wind(MPH) Mil 5'4" 6' 8' 10' 12' 90 4, 120 None 140 XR10 160 90 120 20 140 160 r ; 90 30 160 90 yy 40 f 160 80 160 120 160 in , reant to oe a simghttted span nart or ,I,n .e,;'ng ;er '. tr.), -apabrit;ies t,se ao...oved e,tificanoe i.viers for actua tiestqp 3wdance ©2020 IronRidge,Inc.Alt rights reserved.Visit www.ironridge.com or calf 1-800-227-9523 for more information.Version 1.20 // 0111111 . Airk. IRONRIDGE FlashFoot2° The Strongest Attachment in Sc.'- r IronRidge® FlashFoot2® raises the bar in solar roof protection. The unique water seal design is both �v elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist-on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. � ' " ti , ' Twist-On Cap 7 �" FlashFoot2®'s unique Cap design encapsulates the lag bolt and locks into place with a simple Three-Tier Water Seal twist.The Cap helps FlashFoot2®deliv_ FlashFoot2®'s seal architecture utilizes superior structural strength,by aligning three layers of protection.An elevated the rail and lag bolt in a concentric platform diverts water away,while a stack of load path. - -,may rugged components raises the seal an entire � r v inch.The seal is then fully-encapuslated by the Cap. FlashFoot2®is the first solar attachment to pass the TAS-100 Wind-Driven 4.311 40 t<, avM WRtdb Single Socket Size \■ A custom-design lag bolt allows you to install FlashFoot2®wit the same 7/16"socket size used on other Flush Mount Water-Shedding Design An elevated platform diverts water away from the water seal. s.t °r s., a^' '�ya.�z �wr.^-a. - �WP ,+�xrrxaav�a.ti i�:: µ s ,� �.a'.� � r,., +,awl} Tech Brief Installation Features B A Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. B` Rounded Corners Makes it easier to handle and insert under the roof shingles. C Reinforcement Ribs A�- «. 4.0 H.;`*„ ... ..� 4 5 Help to stiffen the flashing and prevent any bending or crinkling during installation. Benefits of Concentric Loading i= ' rxia Traditional solar attachments have a horizontal offset between the rail and lag a' au *"'"e"® ANON o cmrlwait bolt, which introduces leverage on the lag aFan bolt and decreases uplift capacity. - 5- M LawCaot a.mpollor FlashFoot2® is the only product to align _ the rail and lag bolt. This concentric loading design results in a stronger attachment for the system. Raie,to-►.ag Offset(in) Testing & Certification Structural Certification Designed and Certified for Compliance with the International Building Code &ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by lntertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. 2022 IronRidge,Inc.Ail rights reserved.Visit www.iroaridge.com or call t-880-2 7-8523.for more information.Version 1.01 f