Loading...
42-013 (2) BP-2023-1631 276 WEST FARMS RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 42-013-001 CITY OF NORTHAMPTON Permit: Solid Fuel Appliance PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2023-1631 PERMISSION IS HEREBY GRANTED TO: Project# PELLET STOVE 2023 Contractor: License: Est.Cost: DOUGLAS L'ABBEE CSL99401 Const.Class: Exp.Date: 01/06/2024 Use Group: Owner:- THOMPSON, WAYNE &LACEY, CANDY Lot Size (sq.ft.) Zoning: WSP Applicant: THE FIRE PLACE Applicant Address Phone: Insurance: 100 STATE RD (413)397-3463 WHATLEY, MA 01093 ISSUED ON: 11/20/2023 TO PERFORM THE FOLL O WING WORK: PELLET STOVE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: I iI , 3.- 'I ♦ Fees Paid: $40.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner ��CIV� - Hof Northampton THE �_. - J �to aSsachusetts .- rci' ik G r lit' w ti3 w, I ;, :, tie NOV 1 7 202PEP, `TME OF BUILDING INSPECTIONS y;� r ,c,' A. 212 Mai Street • Municipal Building 0 .. r�, orthampton, MA 01060 Nit a t cpT OF BUILDING INSPECTIONS NORTHAtvr TON.MA 01060 APPLICATION FOR SOLID FUEL APPLIANCE INSTALLATION Property Information Owners Name: 2ont a.S 5eA:7C ' Address: Zo3 Sy/vim fry g r 1/ors,7c� !r t d- (No.) (Street Address) Phone: i//3 6957•G sVV V Cell: Email: Owners Signature: Date:7/� �o�.� Contractor's Infor ation (If Applicable) emal/7<im ff k, /e/A r-p/t c.cna. eoni Name: "i)or /e,f L c.c Phone: //3 3 7-7 F/4 : Construction Supervisor's License #: 5-5'1.- a ''fial Expiration: /-6 ,7/' Home Impr. Contractor License #: /ea 1 77 Expiration: //--/f a54 Stove Information Type of Fuel (check all that apply): Wood V Pellet Coal Location: h Af«h#— Freestanding '( Insert Manufacturer: /// Model: AC cAtc/ /000-C Kc,,,uoinit dC-f) G✓coo 4.ri cc-- f isiet/i%7T /lecu moo.) e� 1«✓f / 5i 7�� FOR BUILDING DEPARTMENT USE ONLY C Permit# v51�' 4 .'/&3 Date Applied: • Total all Fees: $ `►0 L-�, z-. Building Official: / r-ul•-) 4,5 Date Issued: 11-20-2623 (Print) Signature of Building Official: • _ The Commonwealth of Massachusetts ----- Department of Industrial Accidents („iiii -1 i Office of Investigations motel ...., . , Lafayette City Center Y _�o: 2 Avenue de Lafayette, Boston, MA 02111-1750 c�yss� www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual):THE FIRE PLACE - Address:100 STATE ROAD , City/State/Zip:WHATELY, MA 01093 Phone #:413.397.3463 Are you an employer? Check the appropriate box: Type of project (required): 1.0 I am a employer with 10 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. ❑New construction listed on the attached sheet. 7. ❑ Remodeling 2.E I am a sole proprietor or partner ship and have no employees These sub-contractors have 8. ❑ Demolition employees and have workers' working for me in any capacity. 9, ❑ Building addition [No workers' comp. insurance comp, insurance.$ required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, §1(4), and we have no 13.❑ Other employees. [No workers' comp, insurance required.] *My applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: MA RETAIL MERCHANTS WC GROUP INC _ Policy#or Self-ins. Lic. #:01400503301116 Expiration Date:1-1-24 ' Job Site Address: Jai Sy/✓-sic" City/State/Zip: oreitc'� At r-+ Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify u r the pains and alties of perjury that the information provided above is true and correct. Signature: ai( Date: //•/7`'/•"23 Phone#: 413.397.3463 Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License # Issuing Authority (check one): 1❑Board of Health 20 Building Department 3.00ity/Town Clerk 4.1:Electrical Inspector 5FlPlumbing Inspector 6.❑Other Contact Person: Phone#: • General Information The Fire Chief 2020 EPA-Certified Furnace has been engineered to accommodate the heating requirements of the average sized home,even during winter's coldest months. It is constructed with high grade, heavy gauge steel and is continuously welded to assure the highest structural strength. In addition,the firebox is lined with insulated stainless steel panels to ensure many years of energy efficient service.The design of the secondary combustion chamber increases fuel efficiency by creating a"secondary burn" of smoke and wood gases before they are vented up the chimney.The cast iron doors are custom fitted to provide an airtight seal, greatly extending the burn time and ensuring maximum efficiency in fuel consumption. The heavy-gage cast iron grate allows for convenient ash removal and reduced maintenance. For total comfort and convenience, a thermostatically-controlled Draft Blower and fan-limit-controlled Circulation Blower are included. These fully automatic components provide heat disbursement throughout your home, minimizing recovery time when the wall thermostat demands heat. All of these features are standard,offering you the most efficient, durable, and affordable indoor wood burning furnace. Efficiency was determined using the higher heating value of the fuel per B415.1-10 testing requirements. Dry seasoned wood will develop greater BTU output.A well-insulated dwelling will always lead to better results and overall improved fuel usage efficiency. Your Fire Chief Furnace is designed to be either a supplemental or central heating source for your home. This wood burning furnace may be installed in parallel with a properly operating electric, gas or oil-fired central furnace, listed or certified in accordance with a nationally recognized safety standard, and within clearances specified on the nameplate. When in a parallel installation,the static pressure of the central furnace plenum may not exceed 0.15 water column inches, and the maximum setting on the central furnace limit switch is 182°F. With the Fire Chief Furnace in an"Interconnection Arrangement,"your furnace should be upstream of the central furnace. The Fire Chief Furnace warm air supply should never be connected to return air for the central furnace. A qualified installer should perform the installation. IMPORTANT: FOR TECHNICAL SUPPORT OR CUSTOMER SERVICE ISSUES, DO NOT RETURN TO THE STORE OR TO THE DEALER. CALL 1-800-875-4788. Forced Hot Air Circulation: The plenum size of your Fire Chief Furnace must not be reduced to less than 100 square inches, and must provide a minimum of 18 inches between the top of your Fire Chief Furnace and the main trunk connection. Do not modify the outer shell of the furnace at any time.The plenum attached to the furnace must be constructed of metal. The warm air supply duct system should be constructed of materials with a minimum temperature rating of 250°F. Clearances: Unit must be placed on a non-combustible floor. This floor must extend at least 16 inches in front of, and 8 inches on either side of, the fuel loading and ash removal doors; underneath the chimney connector; and 2 inches on either side of the chimney connector. The furnace must maintain the following clearances to combustibles: • Heat plenum=2 inches •Chimney connector= 18 inches • Front=48 inches • Rear= 12 inches •Sides=6 inches • Furnace= 12 inches These are minimum clearances and should be strictly followed. In the case of a power outage, a dangerous level of heat accumulation may develop. Do not store fuel or other combustible materials within installation clearances. 4 Location and Installation NOTE: Before beginning installation, consult proper local authorities regarding local codes governing all such applications and installations. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. Your furnace must be placed on a non- combustible floor. Position the furnace as close to the chimney as possible. Air for combustion must be provided into the room where the furnace is located. Allow air free access to the furnace for combustion and ventilation. The installation of a warm air furnace within an attached garage is prohibited by building codes and regulations. RECOMMENDATION: Smoke detectors and carbon monoxide detectors should be installed on all levels of your home. Having a fire extinguisher within close proximity is strongly recommended. This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual. Return Air Duct Supply Duct 1 440,, Back Draft Dampers '"'"%4414114.• .444041p.444 „7 ...4., , 4, 114040,044 141r, ,oise 5 • CHIMNEY HEIGHT REQUIREMENTS The chimney must extend at least three feet above the highest The termination cap should be designed to point where it passes through the roof surface and at least inhibit down-drafting without restricting two feet higher than any part of the building within a horizontal u) the exhaust discharge. distance of ten feet. 3' min.II 2' 3' min. 111_„04001012 •When installing into an unlined brick chimney,lining the entire chimney with stainless steel chimney liner is strongly recommended.The liner must be 6"for the FC1000E. •The diameter of the chimney stack should be consistent throughout the length of the chimney. 1 •The chimney size should be at least as large as the exhaust stack on the furnace,but not more than twice its size. •The chimney stack should have a built-in airtight clean-out. p C •Do not operate the furnace with the clean-out uncapped. r -1 WARNING- RISK OF FIRE: • Do not operate with flue draft exceeding .08 water column inches (19.9 Pa). • Do not operate with fuel loading or ash removal doors open. • Do not store fuel or other combustible materials within marked installation clearances. • Inspect and clean flues and chimney regularly. DANGER-Risk of Fire and Explosion: •Do not burn garbage,gasoline, naphtha,engine oil,or other flammable liquids/inappropriate materials. WARNING: • NEVER use galvanized pipe in your chimney connection, it produces poisonous gases when subjected to extreme temperatures. • USE only lined masonry or manufactured Class"A"HT2100 All Fuel Chimney for your furnace. •INSPECT chimney system periodically for structural integrity. •CLEAN the chimney system regularly to prevent creosote accumulation. •NEVER leave the ash pan in your furnace during operation. •DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. 9