Hubbard Line Diagram 11.14.23NOTE: READILY ACCESSIBLE OPEN BLADE ACSYSTEM DISCONNECT VISIBLE FROM APPROACHTO RESIDENCE 60A 240V LOCATED EXTERIOR ONWALL NEAR METER NEMA 3RUTILITY METERNUMBER: #93744919EQUIPMENT LEFTOF LINE IS (N) NEWUNLESS OTHERWISE NOTED.EQUIPMENT RIGHTOF LINE IS (E) EXISTINGUNLESS OTHERWISE NOTED.(E) GROUNDINGELECTRODEGROUNDRODTO UTILITYGRID (OH)L2NL1(UPGRADED)(N) MAIN ELECTRICAL PANEL240/120 V 1Ø, 3WMAIN BUSS: 200AMAX BREAKER SIZE:(200A X 1.2) - 200A = 40A(E)UTILITYMETERGNTO (E)LOADS(N) MAIN200AL2L1NL2L1N(N)40A/2PCB1PV SYSTEM EQUIPPED WITH RAPIDSHUTDOWN DISCONNECT PER NEC 690.12SYSTEM COMPLIANT WITH NEC 690.1345GSW1(N) AC DISCONNECT, 60AA9B9(N) (18) RECREC400NP3 BLACK400 WATTS(N) (6) TESLASOLAR SHUTDOWN DEVICE(N) SOLADECKJUNCTION BOX123L2NGGL1(N) TESLA7.6 KW(N) DC DISCONNECTCONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONSIDTYPICALCONDUCTORCONDUITCURRENT-CARRYINGCONDUCTORS IN CONDUITOCPDEGCTEMP. CORR.FACTORCONDUIT FILLFACTORCONT.CURRENTMAX. CURRENT(125%)BASE AMP.DERATEDAMP.TERM. TEMP.RATINGAMP. @TERMINALVOLTAGE DROP1210 AWG PV WIRE, COPPERFREE AIR2N/A6 AWG BARE, COPPER0.96 (32.7 °C)114.24A17.8A55A52.8A75°C50A2110 AWG THWN-2, COPPER0.75'' DIA EMT4N/A10 AWG THWN-2, COPPER0.96 (32.7 °C)0.814.24A17.8A40A30.72A75°C35A3110 AWG THWN-2, COPPER0.75'' DIA PVC-404N/A10 AWG THWN-2, COPPER0.96 (32.7 °C)0.814.24A17.8A40A30.72A75°C35A0.80%418 AWG THWN-2, COPPER0.75'' DIA EMT2N/A8 AWG THWN-2, COPPER0.96 (32.7 °C)132A40A55A52.8A75°C50A518 AWG THWN-2, COPPER0.75'' DIA EMT240A8 AWG THWN-2, COPPER0.96 (32.7 °C)132A40A55A52.8A75°C50ABFADE23DESIGN BY:ACDEGHBCFGH1456DATE:CHECKED BY:REVISIONS V.S.M.M.07.01.2023PAPER SIZE: 11" x 17" (ANSI B)V.2.7 CONTRACTORPHONE:LIC. NO.:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR, LLC.116 PLEASANT ST SUITE 321EASTHAMPTON, MA 01027664A1413-584-8844186338UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDUNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDUNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.ENGINEER OF RECORDNEW PV SYSTEM: 7.200 kWpJAMES BHUBBARDRESIDENCE26 VERNON STREETNORTHAMPTON, MA 01060APN: NHAMM031AB0118L0001E-601.00LINE DIAGRAM(SHEET 7)MODULE STRINGINGMODULE STRINGINGAB