Loading...
685 Bridge Rd Northampton - Electrical plan set w SSSCOPE OF WORK TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE LOCATED AT 685 BRIDGE RD, NORTHAMPTON, MA 01060, USA. THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. EQUIPMENT SUMMARY 30 Q CELLS Q.PEAK DUO BLK ML-G10+ 405 MODULES 1 SOLAREDGE SE10000H-US000BEI4 INVERTER 30 SOLAREDGE POWER OPTIMIZER S440 GENERAL NOTES THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE MODIFICATIONS • CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAIN ALL PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. • CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL COMPENSATION. • DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST. • THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND COMPLETION OF THE WORK WITH APPROVED MATERIALS. • CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDING PERMIT IS PROPERLY DISPLAYED. • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE WITH THE REQUIREMENTS OF THE NATIONAL BUILDING CODE, THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. • IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. • THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. • THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. • CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK.• ELECTRICAL NOTES ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.• ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. • WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. • WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. • WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. • ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.• MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. • MODULE SUPPORT RAIL SHALL BE BONDED TO THE MODULE• GOVERNING CODES 2023 NATIONAL ELECTRICAL CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL RESIDENTIAL CODE AHJ NAME : HAMPSHIRE COUNTY WIRING AND CONDUIT NOTES ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PURPOSE AND APPROVAL FOR THE SITE APPLICATIONS • ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PV WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED • ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE DERATED ACCORDING TO AS PER LATEST NEC CODE. • EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES • PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 1000V AS PER APPLICABLE NEC • 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS • ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION• VOLTAGE DROP LIMITED TO 2%• AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY • SYSTEM RATING 12.150 kWDC 10.000 kWAC PHOTOVOLTAIC SYSTEM FIRE CLASSIFICATION LISTING IN ACCORDANCE WITH UL 1703 STANDARD. SHEET INDEX PV1 COVER PAGE PV2 SITE PLAN PV3 ROOF PLAN PV4 DEAD LOAD CALCULATION PV5 STRING LAYOUT & BOM PV6-PV7 ATTACHMENT DETAILS PV8 ELECTRICAL LINE & CALCS. PV9 SPECIFICATIONS & NOTES PV10-PV11 SIGNAGE PV12-PV18 EQUIPMENT SPECIFICATIONS PROJECT SITE HOUSE PHOTO SCALE: NTS PROJECT SITE VICINITY MAP SCALE: NTS ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME COVER PAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-1 SITE NOTES A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS.• THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.• THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS.• PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110.26]• LEGEND JB (N) JUNCTION BOX UM (E) UTILITY METER MSP (E) MAIN SERVICE PANEL AC (N) FUSED AC DISCONNECT VENT, ATTIC FAN (ROOF OBSTRUCTION) ROOF ATTACHMENT -------CONDUIT S440 OPTIMIZER INV SOLAREDGE SE10000H-US000BEI4 INVERTER Q CELLS Q.PEAK DUO BLK ML-G10+ 405 MODULES IRONRIDGE BLACK XR-100 RAIL 168 TRENCH SCALE: 1/32"= 1'-0" ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME SITE PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-2 DESIGN SPECIFICATION RISK CATEGORY:II CONSTRUCTION:SFD ZONING:RESIDENTIAL SNOW LOAD (ASCE7-10): 35 PSF EXPOSURE CATEGORY: B WIND SPEED (ASCE7-10): 117 MPH MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES: 30 MODULES MODULE TYPE:Q CELLS Q.PEAK DUO BLK ML-G10+ 405 MODULE WEIGHT: 48.5 LBS MODULE DIMENSIONS: 74" X 41.1" = 21.12 SF UNIT WEIGHT OF AREA: 2.3 PSF ROOF DESCRIPTION ROOF ROOF TILT RAFTER SIZE RAFTER SPACING ROOF MATERIAL #1 43° 2" x 10" 16" o.c. Standing Seam Metal #2 19° 2" x 10" 16" o.c. Standing Seam Metal #3 27° 2" x 10" 16" o.c. Standing Seam Metal #4 27° 2" x 10" 16" o.c. Standing Seam Metal ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) #1 9 190.09 #2 7 147.85 #3 7 147.85 #4 7 147.85 (TOTAL ARRAY AREA/TOTAL ROOF AREA) X 100% = (633.63/1361) X 100% = 46.56% LEGEND JB (N) JUNCTION BOX UM (E) UTILITY METER MSP (E) MAIN SERVICE PANEL AC (N) FUSED AC DISCONNECT VENT, ATTIC FAN (ROOF OBSTRUCTION) ROOF ATTACHMENT -------CONDUIT S440 OPTIMIZER INV SOLAREDGE SE10000H-US000BEI4 INVERTER Q CELLS Q.PEAK DUO BLK ML-G10+ 405 MODULES IRONRIDGE BLACK XR-100 RAIL 168 TRENCH SCALE: 1/8"= 1'-0" ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME ROOF PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-3 DEAD LOAD CALCULATION EQUIPMENT'S DESCRIPTIONS QTY LBS/UNIT TOTAL WEIGHT MODULES 30 48.5 1455 MID CLAMP 38 0.3 11.4 END CLAMP 44 0.31 13.64 IRONRIDGE BLACK XR-100 RAIL 168 20 9.55 191.00 SPLICE BAR 4 0.65 2.6 S5!S-5-N CLAMP 83 0.1 8.30 S-5-N INSERT 83 0.1 8.30 M8-1.25 SS HEX FLANGE BOLT(13MM SOCKET) 166 0.1 16.60 3/8-24 SS ROUND POINT SETSCREW(3/16 HEX DRIVE) 166 0.1 16.60 L-FOOT KIT 83 0.1 8.30 TOTAL WEIGHT OF THE SYSTEM (LBS)1731.75 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)633.63 WEIGHT PER SQ. FT. (LBS)2.74 WEIGHT PER PENETRATION (LBS)2.99 ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME DEAD LOAD CALCULATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-4 SCALE: 3/16"= 1'-0"A B C - MODULE STRINGING ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME STRING LAYOUT & BOM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-5 No Preview Available ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME ATTACHMENT DETAILS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-6 ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME ATTACHMENT DETAILS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-7 ID TYPICAL INITIAL CONDUCTOR LOCATION FINAL CONDUCTOR LOCATION CONDUCTOR CONDUIT # OF PARALLEL CIRCUITS CURRENT-CARRYING CONDUCTORS IN CIRCUIT CONDUIT FILL PERCENT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT BASE AMP. DERATED AMP. LENGTH VOTAGE DROP 1 3 ARRAY JUNCTION BOX 10 AWG PV WIRE COPPER MIN 0.75" DIA EMT 1 2 31.71%N/A 6 AWG BARE COPPER 0.76 (54°C)N/A 15.00A 18.75A N/A N/A 45FT 0.73% 2 1 JUNCTION BOX INVERTER 10 AWG THWN 2 COPPER MIN 0.75" DIA EMT 3 6 29.27%N/A 8 AWG THWN-2 COPPER 0.96 (32°C)0.80 15.00A 18.75A 40.00A 30.72A 53FT 0.85% 3 1 INVERTER FUSED AC DISCONNECT 6 AWG THWN 2 COPPER MIN 0.75" DIA EMT 1 3 34.90%60A 8 AWG THWN-2 COPPER 0.96 (32°C)1.00 42.00A 52.50A 75.00A 72.00A 5FT 0.09% 4 1 FUSED AC DISCONNECT MSP 6 AWG THWN 2 COPPER MIN 0.75" DIA EMT 1 2 34.90%N/A N/A THWN-2 COPPER 0.96 (32°C)1.00 42.00A 52.50A 75.00A 72.00A 5FT 0.09% BRANCH 1 (10) Q CELLSQ.PEAK DUO BLK ML-G10+ 405 MODULES = = -+ -+ = = -+ -+ = = -+ -+ BRANCH 2 (10) Q CELLSQ.PEAK DUO BLK ML-G10+ 405 MODULES = = -+ -+ = = -+ -+ = = -+ -+ BRANCH 3 (10) Q CELLSQ.PEAK DUO BLK ML-G10+ 405 MODULES = = -+ -+ = = -+ -+ = = -+ -+ SOLAREDGE POWER OPTIMIZER S440 RATED DC INPUT POWER - 440 WATTS MAXIMUM INPUT VOLTAGE - 60 VDC MPPT RANGE - 8 TO 60 VDC MAXIMUM INPUT CURRENT - 14.50 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS,6000 WATTS STC PER STRING MAXIMUM 1 L2 L2 L1 L1 L2 L2 L1 L1 L2 L2 L1 L1 2 G G 600V NEMA 3R, UL LISTED JUNCTION BOX L1 L2 L1 L2 L1 L2 G G N L2 L1 NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT SOLAREDGE RAPID SHUTDOWN KIT IS INTEGRATED WITH INVERTER. 99% CEC WEIGHTED EFFICIENCY OUTPUT: 240 VAC, 42.00A SOLAREDGE SE10000H-US000BEI4 G ~ L1L2NGL1L2G = L1 3 L2 N G L1 L2 N G (2) 60A FUSES 60A FUSED, (2) 60A FUSES, 240V, NEMA 3R, UL LISTED AC DISCONNECT: L2 L2 L1 L1 L2 L2 L1 L1 L2 L2 L1 L1 L2 (E) MAIN BREAKER TO HOUSE 240V, 125A/2P (E) MAIN SERVICE PANEL, 200A RATED, 1-PH, 3-W, 240V L1 POINT OF INTERCONNECTION SUPPLY SIDE TAP 4 N L2L1 N TO UTILITY GRID (E) BI-DIRECTIONAL UTILITY 1-PH, 3-W, 120V/240V N EXISTING GROUND ELECTRODE CONDUCTOR G SCALE: NTS SERVICE INFO UTILITY PROVIDER:NATIONAL GRID AHJ NAME:HAMPSHIRE COUNTY MAIN SERVICE VOLTAGE:240V MAIN SERVICE PANEL:200 A MAIN BREAKER RATING:125 A SERVICE FEED SOURCE:UNDERGROUND SYSTEM RATING 12.150 kWDC 10.000 kWAC ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME ELECTRICAL LINE & CALCS. SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-8 SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL Q CELLS Q.PEAK DUO BLK ML-G10+ 405 VMP 37.39 V IMP 10.83 A VOC 45.34 V ISC 11.17 A TEMP. COEFF. VOC -0.27%/K PTC RATING 381.37 W MODULE DIMENSION 74"(L) x 41.1"(W) PANEL WATTAGE 405 W INVERTER SPECIFICATIONS MANUFACTURER / MODEL SOLAREDGE SE10000H-US000BEI4 NOMINAL AC POWER 10000 W NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 42 A POWER OPTIMIZER (SOLAREDGE S440) MAXIMUM INPUT POWER 440 W MAXIMUM INPUT VOLTAGE 60 VDC MAXIMUM INPUT ISC 14.5 ADC MAXIMUM OUTPUT CURRENT 15 ADC WEIGHTED EFFICIENCY 98.6% AMBIENT TEMPERATURE SPECS RECORD LOW TEMP -20°C AMBIENT TEMP (HIGH TEMP 2%)32°C CONDUIT HEIGHT 7/8" ROOF TOP TEMP 90°C CONDUCTOR TEMPERATURE RATE 54°C MODULE TEMPERATURE COEFFICIENT OF VOC -0.27%/K PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 0.80 4-6 0.70 7-9 0.50 10-20 ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME SPECIFICATIONS & NOTES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-9 1 WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: POINT OF INTERCONNECTION, MAIN SERVICE DISCONNECT, AC DISCONNECT, AC COMBINER, INVERTER PER CODE: NEC 705.20 2 CAUTION : SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION: POINT OF INTERCONNECTION & INVERTER PER CODE: NEC 690.15 & 705.20 3 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY LABEL LOCATION: MAIN SERVICE DISCONNECT IF MSD IS OUTSIDE PLACE IT THERE / IF MSD IS INSIDE PLACE ON THE AC DISCONNECT PER CODE: NEC 690.12(D) 4 PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT 42 AMPS NOMINAL OPERATING AC VOLTAGE 240 VOLTS LABEL LOCATION: INTERACTIVE SYSTEM POINT OF INTERCONNECTION PER CODE: NFPA 70, NEC 690.54 5 CAUTION CONTAINS MULTIPLE POWER SOURCES LABEL LOCATION: PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES PER CODE: NEC 705.30(C) and 690.59 6 WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: CONDUIT PER CODE: NEC 690.31(D)(2) 7 CAUTION : SOLAR CIRCUIT LABEL LOCATION: MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 1O FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES PER CODE: IFC 606.11.1.4 8 WARNING - Electric Shock Hazard No user serviceable parts inside Contact authorized service provider for assistance LABEL LOCATION: INVERTER & JUNCTION BOXES (ROOF) PER CODE: NEC 690.13 (G)(3) & 690.13 (G)(4) 9 PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.12(D)(2) 10 WARNING DUAL POWER SUPPLY SOURCES: UTILITY AND PV POWER SOURCE ELECTRIC SYSTEM LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 705.12(C) ADHESIVE FASTENED SIGNS THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNING AND MARKINGS SHOULD COMPLY WITH ANSI 2535.4 [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] • ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME SIGNAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-10 LABEL LOCATION: EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED (PER CODE: NEC 705.10) ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME SIGNAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-11 ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-12 ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-13 ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-14 ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-15 ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-16 ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-17 ISAKSEN SOLAR 18 POCASSET ST, FALL RIVER, MA 02721, USA PH# : (508) 717-3820 SYSTEM INFO (30) Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (1) SOLAREDGE SE10000H-US000BEI4 DC SYSTEM SIZE: 12.150 kWDC AC SYSTEM SIZE: 10.000 kWAC REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS ROBERT LANGSTON RESIDENCE685 BRIDGE RD, NORTHAMPTON, MA 01060, USAEMAIL ID: ROB.A.LANGSTON@GMAIL.COMPHONE NO. (413) 588-7414DATE: 10/17/2023 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-18