UFP Preliminary Drawings - 20230518Scale = 1:62.1 PRELI MI N A R Y LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 Right: 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-10, 4-6 REACTIONS (size)6=5-08, (min. 2-05), 10=5-08, (min. 2-05) Max Horiz 10=127 (LC 9) Max Uplift 6=-87 (LC 13), 10=-87 (LC 12) Max Grav 6=1493 (LC 1), 10=1493 (LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-17=-236/506, 2-18=-1656/136, 18-19=-1496/149, 3-19=-1490/164, 3-20=-1483/162, 20-21=-1489/148, 4-21=-1649/135 BOT CHORD 1-10=-97/377, 9-10=-137/1473, 9-23=-12/1048, 23-24=-12/1048, 8-24=-12/1048, 7-8=-12/1048, 6-7=-48/1473 WEBS 2-10=-1735/143, 4-6=-1733/145, 3-9=-76/585, 2-9=-423/172, 3-7=-74/579, 4-7=-424/171 NOTES 1)Wind: ASCE 7-10; Vult=117mph (3-second gust) Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-0-0 to 3-0-0, Interior (1) 3-0-0 to 9-5-4, Exterior (2) 9-5-4 to 15-5-4, Interior (1) 15-5-4 to 21-10-8, Exterior (2) 21-10-8 to 24-10-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 87 lb uplift at joint 10 and 87 lb uplift at joint 6. 7)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 0 Chesterfield Road Leeds, MA T01 Common 5 123051374BR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.62 S Sep 22 2022 Print: 8.620 S Sep 22 2022 MiTek Industries, Inc. Thu May 18 06:38:21 Page: 1 This is a PRELIMINARY drawing; web configuration and lumber could change at the time of production. ID:g9wfyHwT3Kky89lunWo_kMzFMZB-a2GHfbO6WCcGH7?g_Iuvnhjmd6zxT0djLsQOA7zFMPX This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 6.7512 =5x6 =3x4 =4x6 =3x4 =5x6 =5x10 =4x6 =3x4 =5x6 10 9 8 7 62324 1 5 17 22 2 4 18 21 19 20 3 T1 T1 B1 B2 W1W1 W3 W2 W4 W5 HW1 HW2 6-03-10 6-03-10 6-01-10 12-05-04 6-01-10 18-06-14 6-03-10 24-10-08 2-12 23-08-00 2-12 1-05-04 1-02-08 1-02-08 1-02-08 24-10-08 6-10-15 8-04-03 6-10-15 23-05-04 8-02-02 16-06-056-067-06-0522-05-08 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.94 Vert(LL)-0.19 7-9 >999 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.65 Vert(CT)-0.30 7-9 >884 180 TCDL 15.0 Rep Stress Incr YES WB 0.36 Horz(CT)0.05 6 n/a n/a BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 104 lb FT = 20% Scale = 1:54.6 PRELI MI N A R Y LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS All bearings 22-05-08. (lb) -Max Horiz 25=127 (LC 9) Max Uplift All uplift 100 (lb) or less at joint(s) 14, 15, 16, 17, 19, 21, 22, 23, 24, 25 Max Grav All reactions 250 (lb) or less at joint (s) 15, 24 except 14=426 (LC 19), 16=264 (LC 19), 17=276 (LC 19), 19=343 (LC 19), 20=382 (LC 1), 21=343 (LC 18), 22=276 (LC 18), 23=264 (LC 18), 25=426 (LC 18) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-57/253, 12-13=-54/250 WEBS 7-20=-342/0, 6-21=-302/60, 2-25=-291/65, 8-19=-302/60, 12-14=-291/65 NOTES 1)Wind: ASCE 7-10; Vult=117mph (3-second gust) Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) exterior zone and C-C Corner (3) 0-0-0 to 3-0-0, Exterior (2) 3-0-0 to 9-5-4, Corner (3) 9-5-4 to 15-5-4, Exterior (2) 15-5-4 to 21-10-8, Corner (3) 21-10-8 to 24-10-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)All plates are 2x4 MT20 unless otherwise indicated. 6)Gable studs spaced at 2-0-0 oc. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 21, 22, 23, 24, 25, 19, 17, 16, 15, 14. 10)Non Standard bearing condition. Review required. 11)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 0 Chesterfield Road Leeds, MA T01GE Common Supported Gable 1 123051374BR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.62 S Sep 22 2022 Print: 8.620 S Sep 22 2022 MiTek Industries, Inc. Thu May 18 06:38:21 Page: 1 This is a PRELIMINARY drawing; web configuration and lumber could change at the time of production. ID:KkAd2BGfEEOq7cTTz6qnPUzFMYk-a2GHfbO6WCcGH7?g_Iuvnhjx365tT1KjLsQOA7zFMPX This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 6.7512 =3x4 =4x4 =3x4 =3x4252423222120191817161514 1 13 122 3 11 4 10 32 3395 6 8 7 T1 T1 B1 B2 ST6 ST5 ST4 ST3 ST2 ST1 ST5 ST4 ST3 ST2 ST1 12-05-04 12-05-04 12-05-04 24-10-08 1-02-08 1-02-08 23-08-00 24-10-086-067-06-05Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.21 Vert(LL)n/a -n/a 999 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.15 Vert(TL)n/a -n/a 999 TCDL 15.0 Rep Stress Incr YES WB 0.31 Horiz(TL)0.00 14 n/a n/a BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 110 lb FT = 20% Scale = 1:78.2 PRELI MI N A R Y LUMBER TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 Right: 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-6-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 13-14,12-13. WEBS 1 Row at midpt 2-17, 3-14, 5-14, 7-13 REACTIONS (size)10=5-08, (min. 1-08), 13=5-08, (min. 3-09), 17=5-08, (min. 2-06) Max Horiz 17=-190 (LC 10) Max Uplift 10=-69 (LC 13), 13=-110 (LC 12), 17=-90 (LC 12) Max Grav 10=869 (LC 19), 13=2258 (LC 1), 17=1500 (LC 18) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-24=-287/587, 2-3=-1588/136, 3-25=-748/110, 4-25=-727/113, 4-26=-581/122, 5-26=-510/140, 5-27=-470/139, 6-27=-523/121, 6-28=-608/111, 7-28=-639/108, 7-8=-505/104, 9-29=-273/0 BOT CHORD 1-17=-108/435, 16-17=-186/1456, 16-30=-73/1097, 30-31=-73/1097, 15-31=-73/1097, 14-15=-73/1097, 13-14=-452/127, 11-12=-16/595, 10-11=-16/595 WEBS 2-17=-1669/126, 8-10=-614/97, 3-16=-26/532, 2-16=-335/157, 3-14=-1007/202, 7-14=-73/1331, 7-12=-45/508, 8-12=-459/154, 7-13=-2233/155 NOTES 1)Wind: ASCE 7-10; Vult=117mph (3-second gust) Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-0-0 to 3-8-13, Interior (1) 3-8-13 to 14-11-3, Exterior (2) 14-11-3 to 22-4-13, Interior (1) 22-4-13 to 33-7-3, Exterior (2) 33-7-3 to 37-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 90 lb uplift at joint 17, 69 lb uplift at joint 10 and 110 lb uplift at joint 13. 7)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 0 Chesterfield Road Leeds, MA T02 Common 5 123051374BR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.62 S Sep 22 2022 Print: 8.620 S Sep 22 2022 MiTek Industries, Inc. Thu May 18 06:38:21 Page: 1 This is a PRELIMINARY drawing; web configuration and lumber could change at the time of production. ID:9QblRtllpXR9wmX9JVXA1wzFMY6-a2GHfbO6WCcGH7?g_Iuvnhjrm6x3TzSjLsQOA7zFMPX This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 6.7512 =5x6 =3x4 =4x6 =3x4 =3x4 =3x6 =3x6 =5x6 =5x8 =3x6 =3x4 =8x12 =3x4 =4x4 =3x6 =2x4 =5x6 13171630311514 12 11 10 91 24 29 82 732528462627 5 T2 T1 T2 T1 B1 B3B2 W3 W2 W4 W5 W4 W7 W8 W6 HW1 W1 W9 HW1 6-02-00 12-06-00 6-02-00 31-00-00 6-04-00 6-04-00 6-02-00 18-08-00 6-02-00 24-10-00 6-04-00 37-04-00 2-12 36-01-08 2-12 1-05-04 0-15 23-06-03 1-02-08 37-04-00 1-02-08 1-02-08 4-04-12 27-11-00 4-09-04 23-05-04 7-11-12 35-10-12 7-11-12 9-05-00 9-03-00 18-08-006-0611-00-06Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.61 Vert(LL)-0.26 14-16 >999 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.77 Vert(CT)-0.42 14-16 >632 180 TCDL 15.0 Rep Stress Incr YES WB 0.56 Horz(CT)0.04 10 n/a n/a BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 175 lb FT = 20% Scale = 1:76.9 PRELI MI N A R Y LUMBER TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-9-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 2-17, 3-14, 5-14, 7-13 REACTIONS (size)10=5-08, (min. 1-08), 13=5-08, (min. 3-08), 17=5-08, (min. 2-02) Max Horiz 17=-205 (LC 10) Max Uplift 10=-53 (LC 13), 13=-101 (LC 12), 17=-79 (LC 12) Max Grav 10=713 (LC 19), 13=2234 (LC 1), 17=1340 (LC 18) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-18=-411/69, 2-3=-1532/148, 3-4=-743/138, 4-5=-517/156, 5-6=-517/154, 6-19=-608/136, 7-19=-631/125, 7-8=-461/102, 9-20=-389/65, 1-17=-406/83, 9-10=-394/82 BOT CHORD 16-17=-169/1407, 16-21=-63/1043, 21-22=-63/1043, 15-22=-63/1043, 14-15=-63/1043, 13-14=-338/110, 11-12=-28/545, 10-11=-28/545 WEBS 2-17=-1444/59, 8-10=-397/21, 3-16=-40/573, 2-16=-364/160, 3-14=-993/194, 7-14=-61/1240, 7-12=-53/572, 8-12=-478/160, 7-13=-2195/136 NOTES 1)Wind: ASCE 7-10; Vult=117mph (3-second gust) Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-1-12 to 3-7-10, Interior (1) 3-7-10 to 13-11-10, Exterior (2) 13-11-10 to 20-11-6, Interior (1) 20-11-6 to 31-3-6, Exterior (2) 31-3-6 to 34-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 17, 53 lb uplift at joint 10 and 101 lb uplift at joint 13. 7)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 0 Chesterfield Road Leeds, MA T02A Common 1 123051374BR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.62 S Sep 22 2022 Print: 8.620 S Sep 22 2022 MiTek Industries, Inc. Thu May 18 06:38:21 Page: 1 This is a PRELIMINARY drawing; web configuration and lumber could change at the time of production. ID:wnf2q2TlwfsnVqXVHO5?wMzFMXB-2EqgtxPkHWk7vHasX0P8JuF1?WJ4CQZtaWAxiazFMPW This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 6.7512 =4x4 =3x8 =4x6 =3x4 =3x4 =3x8 =3x4 =5x8 =4x6 =4x8 =3x4 =10x12 =3x4 =4x4 =3x6 =3x8 =4x4 17 16 21 22 15 14 13 12 11 10 91 2018 2 8 7319 64 5 T2 T1 T2 T1 W1 W1B1B3B2 W2 W2 W4 W3 W5 W6 W7 W4 W3 W8 5-08-11 11-08-13 5-08-11 28-10-13 5-08-11 17-05-08 5-08-11 23-02-03 6-00-03 6-00-03 6-00-03 34-11-00 1-00 22-03-12 3-09-10 26-01-06 4-11-00 22-02-12 8-06-02 17-03-12 8-09-10 8-09-10 8-09-10 34-11-001-02-0811-00-06Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.52 Vert(LL)-0.20 14-16 >999 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.66 Vert(CT)-0.31 14-16 >868 180 TCDL 15.0 Rep Stress Incr YES WB 0.57 Horz(CT)0.04 10 n/a n/a BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 172 lb FT = 20% Scale = 1:78.2 PRELI MI N A R Y LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 Right: 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 3-19, 7-14, 2-22 REACTIONS All bearings 12-11-00. except 22=5-08, 18=3-08 (lb) -Max Horiz 22=190 (LC 11) Max Uplift All uplift 100 (lb) or less at joint(s) 10, 11, 17 except 14=-228 (LC 13), 22=-126 (LC 12) Max Grav All reactions 250 (lb) or less at joint (s) 11, 13, 15, 16, 17, 18 except 10=322 (LC 19), 14=2256 (LC 1), 22=1827 (LC 18) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-47=-300/572, 2-3=-2151/199, 3-4=-1351/170, 4-48=-1185/178, 5-48=-1108/197, 5-49=-1069/196, 6-49=-1123/177, 6-50=-1214/168, 7-50=-1235/165, 7-8=0/695, 8-51=-5/480, 9-51=-23/318 BOT CHORD 1-22=-110/434, 21-22=-234/1899, 21-52=-127/1589, 52-53=-127/1589, 20-53=-127/1589, 19-20=-127/1589, 19-54=-15/681, 18-54=-15/681, 17-18=-15/681, 16-17=-15/681, 16-55=-15/681, 15-55=-15/681, 14-15=-15/681, 13-14=-278/61, 12-13=-278/61, 11-12=-278/61, 10-11=-278/61, 9-10=-278/61 WEBS 3-19=-982/200, 5-19=-89/552, 7-19=0/495, 7-14=-2082/134, 8-14=-566/173, 2-22=-2206/169, 3-21=-24/491, 2-21=-273/152 NOTES 1)Wind: ASCE 7-10; Vult=117mph (3-second gust) Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-0-0 to 3-8-13, Interior (1) 3-8-13 to 14-11-3, Exterior (2) 14-11-3 to 22-4-13, Interior (1) 22-4-13 to 33-7-3, Exterior (2) 33-7-3 to 37-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)All plates are 2x4 MT20 unless otherwise indicated. 6)Gable studs spaced at 2-0-0 oc. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 11, 10 except (jt=lb) 14=228, 22=126. 10)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 0 Chesterfield Road Leeds, MA T02SGE Common Structural Gable 1 123051374BR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.62 S Sep 22 2022 Print: 8.620 S Sep 22 2022 MiTek Industries, Inc. Thu May 18 06:38:21 Page: 1 This is a PRELIMINARY drawing; web configuration and lumber could change at the time of production. ID:TOgyJ83680AhVWM6Cu?kyvzFMWP-a2GHfbO6WCcGH7?g_IuvnhjmS6vtTwGjLsQOA7zFMPX This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 6.7512 =5x6 =3x4 =5x6 =3x4 =3x4 =3x6 =3x6 =5x6 =3x8 =3x6 =3x6 =4x4 =3x6 =5x62221525320195418171655151413121110 91 5147 2 8 7350464849 5 T2 T1 T2 T1 B1 B3B2 W4 W5 W6 W7 W8W1 W3 W2 HW2 ST2ST1 ST3 ST4 ST5 ST6 ST7 ST8 ST9 ST10 ST11 ST12 ST13 ST14 HW1 6-02-00 31-00-00 6-00-04 18-08-00 6-04-00 6-04-00 6-03-12 12-07-12 6-02-00 24-10-00 6-04-00 37-04-00 2-12 1-05-04 1-02-08 1-02-08 4-08-04 23-04-04 6-03-12 29-08-00 7-08-00 37-04-00 7-10-03 9-03-07 9-04-09 18-08-006-0611-00-06Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.95 Vert(LL)-0.29 19-21 >925 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.91 Vert(CT)-0.49 19-21 >543 180 TCDL 15.0 Rep Stress Incr YES WB 0.76 Horz(CT)0.06 14 n/a n/a BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 219 lb FT = 20% Scale = 1:79.1 PRELI MI N A R Y LUMBER TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 8-7:2x6 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-8-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (size)8=5-08, (min. 1-08), 13=5-08, (min. 1-13) Max Horiz 13=-248 (LC 13) Max Uplift 8=-105 (LC 13), 13=-86 (LC 8) Max Grav 8=1225 (LC 1), 13=1413 (LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-17=-2179/68, 3-17=-2054/76, 3-18=-1769/22, 18-19=-1687/28, 4-19=-1675/38, 4-5=-2413/47, 5-20=-5138/0, 6-20=-5387/0, 6-21=-3797/278, 7-21=-4009/262, 7-8=-1268/149 BOT CHORD 12-13=-162/260, 11-12=-7/2007, 10-11=0/3423, 9-10=-203/3662 WEBS 3-11=-575/121, 4-11=0/1805, 5-11=-2316/75, 5-10=0/3239, 6-10=-17/1287, 6-9=-727/83, 7-9=-138/3108, 2-13=-1283/115, 2-12=-48/1888 NOTES 1)Wind: ASCE 7-10; Vult=117mph (3-second gust) Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-0-0 to 3-0-0, Interior (1) 3-0-0 to 8-5-0, Exterior (2) 8-5-0 to 14-5-0, Interior (1) 14-5-0 to 18-11-12, Exterior (2) 18-11-12 to 21-11-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 6)Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7)Provide metal plate or equivalent at bearing(s) 8 to support reaction shown. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 105 lb uplift at joint 8 and 86 lb uplift at joint 13. 9)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 0 Chesterfield Road Leeds, MA T03 Roof Special 17 123051374BR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.62 S Sep 22 2022 Print: 8.620 S Sep 22 2022 MiTek Industries, Inc. Thu May 18 06:38:21 Page: 1 This is a PRELIMINARY drawing; web configuration and lumber could change at the time of production. ID:Vi1MkyEjCQ_sDhgWckMEYlzFMfE-2EqgtxPkHWk7vHasX0P8JuF1EWMkCM2taWAxiazFMPW This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 412 1212 1212 =3x4 =2x4 =4x6 =5x6 =3x4 =6x8 =4x10 =5x6 =8x8 =4x6 =5x6 =5x8 =3x4 8 7 9 21 6 13 12 11 10 1 2 20175318 19 4 T1 T2 W11 B1 B2 W4 W5 W6 W7 W8 W3 W9 W10 W1 W2 1-05-09 1-05-09 2-02-11 13-07-10 4-04-05 5-09-14 4-02-09 17-10-03 5-07-01 11-05-00 4-04-05 22-02-08 3-01 1-05-09 5-08 22-02-08 1-02-08 1-02-08 2-02-11 13-09-06 4-04-05 5-09-14 4-00-13 17-10-03 5-08-13 11-06-11 3-10-13 21-09-0012-03-086-041-06-004-03-147-11-1021-00-00 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.57 Vert(LL)-0.31 10 >800 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.49 Vert(CT)-0.53 9-10 >465 180 TCDL 15.0 Rep Stress Incr YES WB 0.79 Horz(CT)0.59 8 n/a n/a BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 99 lb FT = 20% Scale = 1:78.1 PRELI MI N A R Y LUMBER TOP CHORD 2x4 SPF No.2 *Except* 4-7:2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 8-7:2x6 SPF No.2 OTHERS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS (size)8=5-08, (min. 1-08), 13=5-08, (min. 2-04) Max Horiz 13=-248 (LC 13) Max Uplift 8=-105 (LC 13), 13=-88 (LC 8) Max Grav 8=1215 (LC 1), 13=1423 (LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-22=-2081/68, 3-22=-1972/76, 3-23=-1756/18, 23-24=-1661/26, 4-24=-1655/35, 4-5=-2375/42, 5-25=-5075/0, 6-25=-5324/0, 6-26=-3761/280, 7-26=-3973/264, 7-8=-1257/149 BOT CHORD 12-13=-240/278, 11-12=-15/1930, 10-11=0/3382, 9-10=-204/3628 WEBS 3-11=-514/123, 4-11=0/1745, 5-11=-2294/75, 5-10=0/3210, 6-10=-17/1265, 3-12=-314/73, 6-9=-717/82, 7-9=-140/3083, 2-13=-1295/104, 2-12=-63/1973 NOTES 1)Wind: ASCE 7-10; Vult=117mph (3-second gust) Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-0-0 to 3-0-0, Interior (1) 3-0-0 to 8-5-0, Exterior (2) 8-5-0 to 14-5-0, Interior (1) 14-5-0 to 18-11-12, Exterior (2) 18-11-12 to 21-11-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)Gable studs spaced at 2-0-0 oc. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 8)Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9)Provide metal plate or equivalent at bearing(s) 8 to support reaction shown. 10)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 105 lb uplift at joint 8 and 88 lb uplift at joint 13. 11)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 0 Chesterfield Road Leeds, MA T03SGE Roof Special 2 123051374BR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.62 S Sep 22 2022 Print: 8.620 S Sep 22 2022 MiTek Industries, Inc. Thu May 18 06:38:21 Page: 1 This is a PRELIMINARY drawing; web configuration and lumber could change at the time of production. ID:Vi1MkyEjCQ_sDhgWckMEYlzFMfE-2EqgtxPkHWk7vHasX0P8JuFx_WEsCM9taWAxiazFMPW 412 1212 1212 =3x4 =2x4 =4x6 =5x6 =3x4 =2x4 =2x4 =2x4 =2x4 =2x4 =2x4 =8x8 =4x10 =5x6 =8x8 =4x6 =6x6 =5x8 =3x4 8 7 9 26 6 13 12 11 10 1 2 25225323 24 4 T1 T2 W11 B1 B2 W4 W5 W6 W7 W8 W3 W9 W10 W1 W2 ST3ST1 ST2 1-07-05 1-07-05 2-02-11 13-07-10 3-09-11 5-05-00 4-02-09 17-10-03 6-00-00 11-05-00 4-04-05 22-02-08 5-08 22-02-08 4-13 1-07-05 1-02-08 1-02-08 2-02-11 13-09-06 3-09-11 5-05-00 4-00-13 17-10-03 3-10-13 21-09-00 6-01-11 11-06-1112-03-086-041-06-004-03-147-11-10Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.90 Vert(LL)-0.32 9-10 >763 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.99 Vert(CT)-0.55 9-10 >442 180 TCDL 15.0 Rep Stress Incr YES WB 0.79 Horz(CT)0.63 8 n/a n/a BCLL 0.0 *Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 104 lb FT = 20%