Loading...
357173_Elizabeth Crow Biladeau_IX - Signed (1)PV-1FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:357173DESIGNED BY:M.K.CLIENT:ELIZABETH CROW BILADEAU38 BRIERWOOD DR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)METER: 5704536PHONE: (413) 923-2233EMAIL: BETSY.YARRA@HOTMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 12 X 380 = 4.560 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 12 X JINKO SOLAR:JKM380M-6RL3-BOPTIMIZERS: 12 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:8/14/2023---------THIS PROJECT COMPLIES WITH THE FOLLOWING:2015 INTERNATIONAL BUILDING CODE2015 INTERNATIONAL RESIDENTIAL CODE2018 INTERNATIONAL MECHANICAL CODE2018 INTERNATIONAL PLUMBING CODE2018 INTERNATIONAL FUEL GAS CODE2018 INTERNATIONAL ENERGY CONSERVATION CODE2015 INTERNATIONAL EXISTING BUILDING CODE2018 INTERNATIONAL SWIMMING POOL AND SPA CODE2020 NATIONAL ELECTRICAL CODEAS ADOPTED BY CITY OF NORTHAMPTON (MA)SITE LOCATIONCODES:VICINITY MAP:TABLE OF CONTENTS:CONSTRUCTION NOTES:ROOF MOUNT PHOTOVOLTAIC SYSTEMPV-1SITE LOCATIONPV-2SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-2BROOF AND STRUCTURAL TABLESPV-3MOUNTING DETAILSPV-4THREE LINE DIAGRAMPV-5CONDUCTOR CALCULATIONSPV-6EQUIPMENT & SERVICE LISTPV-7LABELSPV-7ASITE PLACARDPV-8OPTIMIZER CHARTPV-9SAFETY PLANPV-10SAFETY PLANAPPENDIXMANUFACTURER SPECIFICATION SHEETSCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS ANDARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENTPOSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY AREMOUNTED.MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION INACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PERSECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANYEXCAVATION TAKING PLACEPHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROMDC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A).SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITHREQUIREMENTS OF ART. 690 OF THE 2020 NECTHE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFERUTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEMSOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDSINSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITATTACHED TO THE ROOF USING CONDUIT MOUNT.SITE LOCATIONGREG ALBRIGHT UMMSPACINV JBSITE PLANSCALE: 0.0048581PV-2FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:357173DESIGNED BY:M.K.CLIENT:ELIZABETH CROW BILADEAU38 BRIERWOOD DR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)METER: 5704536PHONE: (413) 923-2233EMAIL: BETSY.YARRA@HOTMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 12 X 380 = 4.560 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 12 X JINKO SOLAR:JKM380M-6RL3-BOPTIMIZERS: 12 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:8/14/2023---------ROOF AREA: 2500 SQ FTSITE PLANLEGEND:CHIMNEYPIPE VENTMODULESCONDUITSETBACKAC DISCONNECTUTILITY METERJUNCTION BOXINVERTERMAIN SERVICEPANELACUMJBINVMSPGREG ALBRIGHTROOF LINEPROPERTY LINEFENCE/GATE(E) MAIN SERVICE PANEL(N) 12 JINKO SOLAR: JKM380M-6RL3-B(N) SOLAREDGE SE3800H-USRGM [SI1](E) UTILITY METER(N) JUNCTION BOX(N) UTILITY DISCONNECT EATON DG221URB(OR EQUIVALENT)52'-2"13'-10"69' -5 "12'-4"15'-11"DRIVEWAYBRIERWOOD DR UMMSPACINV JBPV-2AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:357173DESIGNED BY:M.K.CLIENT:ELIZABETH CROW BILADEAU38 BRIERWOOD DR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)METER: 5704536PHONE: (413) 923-2233EMAIL: BETSY.YARRA@HOTMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 12 X 380 = 4.560 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 12 X JINKO SOLAR:JKM380M-6RL3-BOPTIMIZERS: 12 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:8/14/2023---------ROOF PLANSCALE: 0.0077991NOTES:1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES3.JUNCTION BOX IS MOUNTED TO THE RAIL.ROOF AREA: 2500 SQ FTROOF PLAN WITH MODULES LAYOUTLEGEND:CHIMNEYPIPE VENTMODULESCONDUITSETBACKAC DISCONNECTUTILITY METERJUNCTION BOXINVERTERMAIN SERVICEPANELACUMJBINVMSPGREG ALBRIGHTTOTAL ROOF AREA: 2500 SQ FTTOTAL ARRAY AREA: 246.56 SQ FTARRAY COVERAGE: 9.86%SYSTEM DISTRIBUTED WEIGHT: 2.31 LBSROCKIT SMART SLIDE POINT-LOAD: 29.94 LBS(E) MAIN SERVICE PANEL(N) 12 JINKO SOLAR: JKM380M-6RL3-B(N) SOLAREDGE SE3800H-USRGM [SI1]INVERTER(N) AC DISCONNECT EATON DG221URB (OREQUIVALENT)(N) JUNCTION BOX(E) UTILITY METER PV-2BFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:357173DESIGNED BY:M.K.CLIENT:ELIZABETH CROW BILADEAU38 BRIERWOOD DR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)METER: 5704536PHONE: (413) 923-2233EMAIL: BETSY.YARRA@HOTMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 12 X 380 = 4.560 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 12 X JINKO SOLAR:JKM380M-6RL3-BOPTIMIZERS: 12 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:8/14/2023---------ROOF DETAILSGREG ALBRIGHTROOF AREA STATEMENTROOFMODULE QUANTITYROOF PITCHARRAY PITCHAZIMUTHROOF AREAARRAY AREAROOF 1122222240.65776.28 SQ FT246.56 SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FTROOF DETAILS:TOTAL ROOF AREA: 2500 SQ FTTOTAL ARRAY AREA: 246.56 SQFTARRAY COVERAGE: 9.86%SYSTEM DISTRIBUTED WEIGHT: 2.31 LBSROCKIT SMART SLIDE POINT-LOAD: 29.94 LBS ROCKIT MOUNTROOF SURFACESKIRTROCKIT MOUNTROOFMEMBRANEJINKO SOLAR:JKM380M-6RL3-BROCKIT MOUNTROOFMEMBRANE2" MIN. EMBED.2" MIN. EMBED.2 x #12 WOOD SCREWWITH 2" MIN. EMBEDMENTAND FLAT WASHER2 x #12 WOOD SCREWWITH 2" MIN. EMBEDMENTAND FLAT WASHERVARIES2 x #12 WOOD SCREWWITH 2" MIN. EMBEDMENTAND FLAT WASHER2" MIN. EMBED.2X4 TRUSS @ 24" O.C.JINKO SOLAR: JKM380M-6RL3-BJINKO SOLAR:JKM380M-6RL3-B3" MIN.6" MAX.TABLE 1 - ARRAY INSTALLATIONROOFPITCHROOFING TYPEATTACHMENT TYPEFRAMING TYPEMAX UNBRACEDLENGTH(FT.)STRUCTURALANALYSIS RESULTPENETRATIONPATTERNMAXATTACHMENTSPACING (IN.)MAX RAILOVERHANG(IN.)ROOF 122Comp ShingleEcofasten RockIt Smart Slide2x4 @ 24" O.C.5PASSSTAGGERED72241. CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION. IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS, NOTIFY ENGINEER OF RECORD IMMEDIATELY.2. WHERE COLLAR TIES OR RAFTER SUPPORTS EXIST, CONTRACTOR SHALL USE RAFTERS WITH COLLAR TIES AS ATTACHMENT POINTS.3. MAX RAIL OVERHANG APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS.ATTACHMENT DETAILScale: NTSSOLAR PV ARRAY SECTION VIEWScale: NTSPV-3FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:357173DESIGNED BY:M.K.CLIENT:ELIZABETH CROW BILADEAU38 BRIERWOOD DR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)METER: 5704536PHONE: (413) 923-2233EMAIL: BETSY.YARRA@HOTMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 12 X 380 = 4.560 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 12 X JINKO SOLAR:JKM380M-6RL3-BOPTIMIZERS: 12 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:8/14/2023---------MOUNTING DETAILSGREG ALBRIGHTSTAGGERED DETAILFor Illustration purposes onlySTACKED DETAILFor Illustration purposes only SOLAREDGE S440POWER OPTIMIZERSJUNCTIONBOX2 - #10 AWG, PV WIRE1 - #6 AWG IN FREE AIR OR#10 AWG MUST BE IN EMT CONDUIT STRING-112 JINKO SOLAR: JKM380M-6RL3-B2 - #10 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" ORLARGER EMT CONDUITUM(E) 100A / 2P MAINBREAKER(TOP FED)(E) 125A RATEDMAIN SERVICE PANEL1PH, 120/240V 60HZ(E) UTILITYMETER(N) 20A / 2P PV BREAKERTO OTHER LOADSTO UTILITYOVERHEADFEED3 - #10 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) 30A RATEDAC DISCONNECTEATON DG221URB (OREQUIVALENT) KNIFEBLADE, LOCKABLE,NEMA 3R, UL LISTED3 - #10 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) SOLAREDGESE3800H-USRGM [SI1]INVERTERACDCRAPIDSHUTDOWNSWITCHNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONSBACKFEED BREAKER SIZINGMAX. CONTINUOUS OUTPUT 16.00A @ 240V16.00X1.25=20.00AMPS20A BREAKER - OKSEE 705.12 OF 2020 NEC125X1.20=150150-100=50A ALLOWABLE BACKFEEDPV-4FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:357173DESIGNED BY:M.K.CLIENT:ELIZABETH CROW BILADEAU38 BRIERWOOD DR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)METER: 5704536PHONE: (413) 923-2233EMAIL: BETSY.YARRA@HOTMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 12 X 380 = 4.560 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 12 X JINKO SOLAR:JKM380M-6RL3-BOPTIMIZERS: 12 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:8/14/2023---------THREE LINE DIAGRAMGREG ALBRIGHT PV-5FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:357173DESIGNED BY:M.K.CLIENT:ELIZABETH CROW BILADEAU38 BRIERWOOD DR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)METER: 5704536PHONE: (413) 923-2233EMAIL: BETSY.YARRA@HOTMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 12 X 380 = 4.560 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 12 X JINKO SOLAR:JKM380M-6RL3-BOPTIMIZERS: 12 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:8/14/2023---------CONDUCTOR CALCULATIONSGREG ALBRIGHTWIRE SCHEDULERACEWAY#EQUIPMENTCONDUCTORQTY.AWGWIRESIZESTARTINGALLOWABLEAMPACITY @ 90°C310.15(B)(16)STARTINGCURRENTAPPLIED TOCONDUCTORSIN RACEWAYTEMPERATURECORRECTIONFACTOR310.15(B)(2)(a)ADJUSTMENTFACTOR FORMORE THAN 3CONDUCTORS310.15(B)(3)(a)ADJUSTEDCONDUCTORAMPACITY@ 90°CMAXIMUMCURRENTAPPLIED TOCONDUCTORSIN RACEWAY1DCMODULETOOPTIMIZER2104013.901140.0017.382DCOPTIMIZERTOJUNCTION BOX2104015.001140.0018.753DCJUNCTION BOXTOINVERTER2104015.001140.0018.754ACINVERTERTOAC DISCONNECT3104016.001140.0020.005ACAC DISCONNECTTOPOI3104016.001140.0020.00--------------------------------------------------------------------------------CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST:PV-6FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:357173DESIGNED BY:M.K.CLIENT:ELIZABETH CROW BILADEAU38 BRIERWOOD DR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)METER: 5704536PHONE: (413) 923-2233EMAIL: BETSY.YARRA@HOTMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 12 X 380 = 4.560 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 12 X JINKO SOLAR:JKM380M-6RL3-BOPTIMIZERS: 12 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:8/14/2023---------QTY.PARTPART #DESCRIPTION12MODULESPV-118-380JINKO SOLAR: JKM380M-6RL3-B12OPTIMIZERSOPT-130-440-2SOLAREDGE S440 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON1JUNCTION BOXRAC-260-049600VDC NEMA 3R UL LISTED JUNCTION BOX2ELECTRICAL ACCESSORIESEA-350-326STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE)2EQUIPMENT ACCESSORIESEA-350-327STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE)1INVERTERSINV-120-388SE3800H-US [SI1] RGM 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN1MONITORING EQUIPMENTME-180-502SOLAREDGE CELL MODEM1DISCONNECTSEE-321-03030A RATED 240VAC NEMA 3R UL LISTED19FITTINGS/ANCHORSRAC-265-034ROCKIT SMART SLIDE21FOOTINGS RAC-265-004"MFG: ECO FASTEN, ROCKIT COMP COUPLING AL BLK, MFG SKU: 2011021"19FITTINGS/ANCHORSRAC-265-002"MFG: ECO FASTEN, ROCKIT COMP SLIDE AL BLK, MFG SKU: 2011013"19FOOTINGS RAC-265-001"MFG: ECO FASTEN, GF-1 FLASHING GLV BLK 8X10"", MFG SKU: 3012020"FOOTINGS RAC-265-028"MFG: ECO FASTEN, SKIRT AL BLK 35MM & 40MM A80, MFG SKU: 2099012"FITTINGS/ANCHORSRAC-265-031"MFG: ECO FASTEN, SKIRT END CAP PLS 35MM&40MM-A, MFG SKU: 2099035"12RAILSRAC-265-018"MFG: ECO FASTEN, FRAME MLPE MOUNT SS, MFG SKU: 4011012"38SCREWRAC-265-035ROCKIT SCREW #12X3OCPD SIZES:20A BREAKERSERVICE LIST:NONEEQUIPMENT & SERVICE LISTGREG ALBRIGHT NOTES:M690.13(B)MAIN PHOTOVOLTAICSYSTEM DISCONNECTTURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCE SHOCKHAZARD IN THE ARRAYIFC 605.11.3.1(1) & 690.56(C)SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNAC NEC 690.13(B)INVERTERDCSOLAR PV DC CIRCUITEVERY 10' ON CONDUIT AND ENCLOSURESSOLAR ELECTRICPV PANELS706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANEL!WARNINGSINGLE 120-VOLT SUPPLYDO NOT CONNECTMULTIWIRE BRANCH CIRCUITSNEC 710.15(C) & 692.9 (C)NEC 690.15 (B) & NEC 690.33(D)(2)DO NOT DISCONNECTUNDER LOADNEC 705.12(D) & NEC 690.59!CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDNEC 705.12(D) & NEC 690.59NEC 705.12(C) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGPOWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE.!WARNINGARC FLASH AND SHOCK HAZARDAPPROPRIATE PPE REQUIRED24 INCH3480 VAC42 INCH12 INCH1 INCHFLASH HAZARD BOUNDARYCAL/CM^2 FLASH HAZARD AT 18 INCHESSHOCK HAZARD WHEN COVER IS REMOVEDLIMITED APPROACHRESTRICTED APPROACH - 500 V CLASS 00 GLOVESPROHIBITED APPROACH - 500 V CLASS 00 GLOVESLOCATION:38 BRIERWOOD DR,NORTHAMPTON, MA 01062PHOTOVOLTAICAC DISCONNECTPHOTOVOLTAIC AC DISCONNECTRATED AC OUTPUT CURRENT:NOMINAL OPERATING AC VOLTAGE:16.00A240V!WARNINGTHIS EQUIPMENT FED BYMULTIPLE SOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEED AMPACITY OF BUSBARNEC 690.54NEC 705.12(B)(3)(3)NEC 706.15(C) AND NEC 110.16PM NEC 705.12(D) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENTNEC 690.31(E)PHOTOVOLTAIC POWER SOURCEEVERY 10' ON CONDUIT AND ENCLOSURESNEC 690.31NEC 690.31(D)(2) NEC 690.13(B)PHOTOVOLTAICDC DISCONNECT706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHT NEC 690.53MAXIMUM DC VOLTAGEOF PV SYSTEMARRAYJ/BNEC 690.31(G)(3) & (4)706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEM690.56(C)(3)MAXIMUM VOLTAGEMAXIMUM CIRCUIT CURRENTMAX DC-DC CONVERTEROUTPUT CURRENTVAA10.548015PV-7FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:357173DESIGNED BY:M.K.CLIENT:ELIZABETH CROW BILADEAU38 BRIERWOOD DR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)METER: 5704536PHONE: (413) 923-2233EMAIL: BETSY.YARRA@HOTMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 12 X 380 = 4.560 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 12 X JINKO SOLAR:JKM380M-6RL3-BOPTIMIZERS: 12 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:8/14/2023---------LABELSGREG ALBRIGHT1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINEWORK.C.ARIAL FONT.3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED INTHE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENTWITH POP-RIVETS OR SCREWS CAUTION:PV-7AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:357173DESIGNED BY:M.K.CLIENT:ELIZABETH CROW BILADEAU38 BRIERWOOD DR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)METER: 5704536PHONE: (413) 923-2233EMAIL: BETSY.YARRA@HOTMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 12 X 380 = 4.560 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 12 X JINKO SOLAR:JKM380M-6RL3-BOPTIMIZERS: 12 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:8/14/2023---------1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C.AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.NOTES:SITE PLACARDGREG ALBRIGHTWARNINGTURN OFF PHOTOVOLTAIC AC DISCONNECTPRIOR TO WORKING INSIDE PANELNPOWER TO THIS BUILDING ISALSO SUPPLIED FROM THEFOLLOWING SOURCES WITHDISCONNECTS AS SHOWNJUNCTION BOX12 PV MODULESUTILITY METERMAIN SERVICE PANELAC DISCONNECTINVERTER EQUIPPEDWITH RAPID SHUTDOWN PV-8FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:357173DESIGNED BY:M.K.CLIENT:ELIZABETH CROW BILADEAU38 BRIERWOOD DR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)METER: 5704536PHONE: (413) 923-2233EMAIL: BETSY.YARRA@HOTMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 12 X 380 = 4.560 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 12 X JINKO SOLAR:JKM380M-6RL3-BOPTIMIZERS: 12 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:8/14/2023---------SOLAREDGE OPTIMIZER CHARTOPTIMIZER CHARTGREG ALBRIGHT11-1516-3031-4546-6023456789101112131415 UMMSPACINV JBPV-9FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:357173DESIGNED BY:M.K.CLIENT:ELIZABETH CROW BILADEAU38 BRIERWOOD DR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)METER: 5704536PHONE: (413) 923-2233EMAIL: BETSY.YARRA@HOTMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 12 X 380 = 4.560 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 12 X JINKO SOLAR:JKM380M-6RL3-BOPTIMIZERS: 12 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:8/14/2023---------SAFETY PLANGREG ALBRIGHTSAFETY PLANMARK UP KEYINSTRUCTIONS:1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2.SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THEPRE-PLAN3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ONTHE JHA SHEETINCIDENT REPORTING:INJURIES - CALL INJURY HOTLINE(855) 400-7233*If injury is life threatening, call 911 first THEN the Injury HotlineNON-INJURIES - USE MOBILE INCIDENT REPORTING(Auto, Property Damage, Near Miss)NEAREST OCCUPATIONAL/INDUSTRIAL CLINIC:NAME: _______________________________________________ADDRESS: ___________________________________________NEAREST HOSPITAL:NAME:_______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATION:NAME: _______________________________________________PHONE NUMBER: _____________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN ANDSIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THEPLAN FOR WORKING SAFELY. NAME SIGNATURE__________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEPGRADE OR GROUND LEVELOBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2OBREAK AND WATER LOGTHIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES. THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS ISCOMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREESNAME0800HRS0900HRS1000HRS1100HRS1200HRS1300HRS1400HRS1500HRS1600HRS JOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder Access·Ladders must be inspected before each use.·Extension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.·Extension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.·A-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).·Additional notes:Mobile Equipment·Only Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.·Type(s) of mobile equipment (Type/Make/Model):·Qualified operator(s):Material Handling and Storage·Materials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall Protection·A site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.·First-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.·FPCP (name and title):·FPU and LPD (name and title):Electrical Safety·The Electrical Qualified Person (EQP) is required onsite toperform electrical work.·All electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.·Service drops and overhead electrical hazards will be indentifiedand protected from contact, as neccessary.·EQP (name and tile):Public Protection·The safety of the Client and Public must be maintained at alltimes.·The Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.·Company, Client and Public property shall be protected fromfalling objects.·Pets (including dogs) shall be secured by their owners prior towork start.·The Client should not leave pets, family members, or others incharge or care of Employees, Contractors, or TemporaryWorkers.·Crew leader responsible for communication with the client:·Client and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety Briefing·All employees onsite shall be made aware of the specific hazardsof this project and review this HJA during a pre-job briefing, andtheir signature indicates awareness of site conditions and theplan to eliminate any hazards identified prior to and during theproject.·Crew leader (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):Airborne Contaminants:·Asbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)·Asbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.·If yes, list specific tasks and protection in place:Weather and Environment·The site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)·The site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, by checkingat the ground and on any elevated work surface (ex, rooftop)prior to work start, at midday and prior to solar panel staging on aroof.·Elevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.·Forecasted weather maximum temp (degrees f):Heat Related Illness Prevention·Employees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.·Shade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.·New employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.·Employees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.·Cool Vests are encouraged for all employees at all times duringperiods of high heat.·Identify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?·If offsite replenish is necessary, where will you go to replenishwater (location/address):·Who will replenish the drinking water (name):Restroom facilities·Employees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.·Restroom facilities will be (circle one): Onsite - Offsite·If Offsite, add location name and address:Incident Reporting Procedure·Contact your Site SupervisorName:Phone:·Contact your ManagerName:Phone:·Contact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:PV-10FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:357173DESIGNED BY:M.K.CLIENT:ELIZABETH CROW BILADEAU38 BRIERWOOD DR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)METER: 5704536PHONE: (413) 923-2233EMAIL: BETSY.YARRA@HOTMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 12 X 380 = 4.560 kWSYSTEM SIZE (AC): 3.800 kW @ 240VMODULES: 12 X JINKO SOLAR:JKM380M-6RL3-BOPTIMIZERS: 12 X SOLAREDGE S440INVERTER: SOLAREDGE SE3800H-USRGM[SI1]DATE:8/14/2023---------SAFETY PLANGREG ALBRIGHT SCAN QR CODE TO ACCESS REFERENCE LINKPV INSTALLATION REFERENCESFREEDOM REFERENCESBATTERY INSTALLATION REFERENCESENPHASE IQ8SOLAREDGE HD WAVE TESLA INVERTERINSTALL HOTLINETESLA POWERWALL 2SHIFT/SELF CONSUMPTION SOLAREDGE ENERGY BANKSOLAREDGE LG RESU (BACKUP) TESLA POWERWALL+ (BACKUP)FOR INSTALLATION REFERENCE ONLYV1.2 • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer• Top performance in the strictest 3rd party labs• Premium solar factories in USA, Vietnam, and MalaysiaEAGLE 66TR G4380-400 WATT TILING RIBBON MODULEPositive power tolerance of 0~+3%KEY FEATURESBUILDING YOUR TRUST IN SOLAR.WWW.JINKOSOLAR.USSOLAR PRODUCT THE MOST DEPENDABLE TR TechnologyTiling Ribbon eliminates cell gaps to increase module efficiency and power.9BB Half Cell TechnologyUniquely designed 9 busbar half cut solar cells deliver ultra-high power in a small footprint. Shade TolerantTwin array design allows continued performance even with shading by trees or debris.Thick and ToughFire Type 1 rated module engineered with a thick frame, 3.2mm front side glass, and thick backsheet for added durability.Leading Warranty25-year product and 25-year linear power warranty; 98% guaranteed first year, max 0.55% annual loss.25turer3%ENGINEERING DRAWINGSPACKAGING CONFIGURATIONTEMPERATURE CHARACTERISTICSMAXIMUM RATINGSMECHANICAL CHARACTERISTICSELECTRICAL CHARACTERISTICSNo. of Cells 132 (2x66)Dimensions 1855x1029x35mm (73.03×40.51×1.37 in)Weight 21.5 kg (47.40 lbs)Front Glass 3.2mm, Anti-Reflection CoatingHigh Transmission, Low Iron, Tempered GlassFrame Anodized Aluminum AlloyJunction Box IP67 RatedOutput Cables 12 AWG, 2053mm (80.83in) or Customized Length Connector Staubli MC4Fire Type Type 1Pressure Rating 5400Pa (Snow) & 2400Pa (Wind)2 pallets = 1 stack; 30pcs/pallets, 60pcs/stack, 720pcs/ 40’HQ ContainerTemperature Coefficients of Pmax -0.35%/°CTemperature Coefficients of Voc -0.28%/°CTemperature Coefficients of Isc 0.048%/°CNominal Operating Cell Temperature (NOCT) 45 ± 2°COperating Temperature (°C) -40°C~+85°CMaximum System Voltage 1000VDCMaximum Series Fuse Rating 20AModule Type JKM380M-6RL3-B JKM385M-6RL3-B JKM390M-6RL3-B JKM395M-6RL3-B JKM400M-6RL3-BSTC NOCT STC NOCT STC NOCT STC NOCT STC NOCTMaximum Power (Pmax) 380Wp 283Wp 385Wp 286Wp 390Wp 290Wp 395Wp 294Wp 400Wp 298WpMaximum Power Voltage (Vmp) 36.90V 33.70V 37.02V 33.90V 37.15V 34.02V 37.27V 34.13V 37.39V 34.25VMaximum Power Current (Imp) 10.30A 8.39A 10.40A 8.45A 10.50A 8.53A 10.60A 8.61A 10.70A 8.69AOpen-circuit Voltage (Voc) 44.22V 41.74V 44.34V 41.85V 44.47V 41.97V 44.59V 42.09V 44.71V 42.20VShort-circuit Current (lsc) 11.12A 8.98A 11.22A 9.06A 11.32A 9.14A 11.42A 9.22A 11.52A 9.30AModule Efficiency STC (%) 19.91% 20.17% 20.43% 20.69% 20.96%ELECTRICAL PERFORMANCE & TEMPERATURE DEPENDENCEBUILDING YOUR TRUST IN SOLAR. WWW.JINKOSOLAR.US*STC: Irradiance 1000W/m2NOCT: Irradiance 800W/m2*Power measurement tolerance: +/- 3% Cell Temperature 25°CAmbient Temperature 20°CAM = 1.5AM = 1.5 Wind Speed 1m/sThe company reserves the final right for explanation on any of the information presented hereby. JKM380-400M-6RL3-B-A2-USVoltage (V)Temperature Dependence of Isc, Voc, PmaxCurrent-Voltage & Power-Voltage Curves (400W)FrontSideBackLength: +/- 2mmWidth: +/- 2mmHeight: +/- 1mmRow Pitch: +/- 2mmCell Temperature (°C)• ISO9001:2008 Quality Standards• ISO14001:2004 Environmental Standards• IEC61215, IEC61730 certified products• UL61730 Certification• ISO45001:2018 Occupational Health & Safety Standards PP  PP  $$+PP  PP  PP  &%       IscVocPmax5&%$ Product specificationsEaton DG221URBCatalog Number: DG221URBEaton General duty non-fusible safety switch, single-throw, 30 A, 240 V,NEMA 3R, Rainproof, Painted galvanized steel, Two-pole, Two-wireGeneral specificationsEaton general duty non-fusible safetyswitchDG221URB7821131202326.88 in 10.81 in6.38 in 6 lbEaton Selling Policy 25-000, one (1) yearfrom the date of installation of theProduct or eighteen (18) months from thedate of shipment of the Product,whichever occurs first.UL ListedWARNING! Switch is not approved forservice entrance unless a neutral kit isinstalled.Product Name Catalog NumberUPCProduct Length/Depth Product HeightProduct Width Product WeightWarranty CertificationsCatalog NotesEaton Corporation plcEaton House30 Pembroke RoadDublin 4, IrelandEaton.com© 2023 Eaton. All RightsReserved.Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners.Eaton.com/socialmediaProduct specificationsGeneral duty safety switchPainted galvanized steelNon-fusible, single-throwNon-fusible2NEMA 3R240V30ATwo-poleResourcesEaton's Volume 2—Commercial DistributionDouble Up on SafetySwitching Devices Flex CenterEaton Specification Sheet - DG221URBProduct CategoryEnclosure materialTypeFuse configurationNumber of wiresEnclosureVoltage ratingAmperage RatingNumber Of PolesCatalogsMultimediaSpecifications and datasheets ;5,60$576/,'(%/. 52&.,7)/$6+/(666/,'($66(0%/<$'+(6,9(5(/($6(/,1(5,7(012'(6&5,37,2152&.,760$576/,'($66(0%/<3$57180%(5'(6&5,37,215,60$576/,'(%/.0$7(5,$/$/80,180(3'0$'+(6,9(75($7('3$3(5),1,6+%/$&.5HY&61.317.82.8772.83.0076.2.5514.0.4210.5RI SMART SCREW #12X3" W/BWPART NUMBERDESCRIPTION2011025RI SMART SCREW #12X3" W/BWITEM NO.DESCRIPTION1SELF TAPPING SCREW #12 WITH SEALING WASHER ASSEMBLYMATERIALSTAINLESS STEEL, EPDM RUBBERFINISHMILL, BLACKRev: CS-2 5Ζ&2036/Ζ'($/%/. 52&.,796/,'(&2030DWHULDO$OXPLQXP)LQLVK%ODFN,7(012'(6&5,37,2152&.,796/,'(&203/$*6&5(:7+5($'(3'0%$&.(':$6+(53$57180%(5'(6&5,37,215,&2036/,'($/%/.REV.- CS15Ζ&2036/Ζ'($/%/. /$*6&5(:7+5($'(3'0%$&.(':$6+(5 7+'+HDG0DWHULDO6WDLQOHVV6WHHO)LQLVK0LOOREV.- CS1 *))/$6+Ζ1**/9%/.; *)0*$/%/.:2:$6+(5$66(0%/<,7(012'(6&5,37,21*)0*$/%/.:2:$6+(5$66(0%/<3$57180%(5'(6&5,37,21*))/$6+,1**/9%/.;REV.- CS17+580DWHULDO&RUURVLRQ5HVLVWDQW6WHHO)LQLVK%ODFN