Loading...
Maginnis, William Engineering 08-01-23 (1) 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com July 31, 2023 Revised August 1, 2023 Empower Energy Solutions 30 Old Kings Highway South #1001 Darien, CT 06820-4551 Roof Material: Composite Asphalt Shingles Roof Slopes: 22 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 psf • Live Load = 20 psf (reducible) – 0 psf at locations of solar panels • Ground Snow Load = 40 psf • Wind Load based on ASCE 7-10 o Ultimate Wind Speed = 117 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2015 International Residential Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing members will support the additional panel loading without damage, if installed correctly. Re: Engineering Services Maginnis Residence 79 Golden Drive 12 Lot 12, Northampton, MA 5.925 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A.Site Assessment Information 1.Site visit documentation identifying attic information including size and spacing of framing members for the existing roof structure. 2.Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B.Description of Structure: Roof Framing: 2x6 dimensional lumber at 16” on center. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Ironridge installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16” lag screw is 2 29 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of 2½” embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on centers. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2015 IRC, current industry standards and practice, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE MA License No. 50507 COA# 001629764 Signed 8/01/2023 CUSTOMER INFO WILLIAM T DRAFTER 29/07/2023 M INV AC MSP B μ D LC ATS CITY OF NORTHAMPTON, CITY HALL, 210 MAIN STREEY, MA 01060 PHONE: 413-587-4900 MODULES: (15) CANADIAN CS6R-395MS-HL A AC BLDG CONC C D DC EGC (E) EMT GALV GEC GND HDG I Imp INVS Isc kVA kW LBW MIN (N) NEC NIC NTS OC P PL PV PVC S SCH SS SSD STC SWH TYP UON UPS V Vmp Voc W 3R AMPERE ALTERNATING CURRENT BUILDING CONCRETE COMBINER BOX DISTRIBUTION PANEL DIRECT CURRENT EQUIPMENT GROUNDING CONDUCTOR EXISTING ELECTRICAL METALLIC TUBING GALVANIZED GROUNDING ELECTRODE CONDUCTOR GROUND HOT DIPPED GALVANIZED CURRENT CURRENT AT MAX POWER INVERTERS SHORT CIRCUIT CURRENT KILOVOLT AMPERE KILOWATT LOAD BEARING WALL MINIMUM NEW NATIONAL ELECTRIC CODE NOT IN CONTRACT NOT TO SCALE ON CENTER PANEL BOARD PROPERTY LINES PHOTOVOLTAIC POLYVINYL CHLORIDE SUBPANEL SCHEDULE STAINLESS STEEL SEE STRUCTURAL DIAGRAMS STANDARD TESTING CONDITIONS SOLAR WATER HEATER TYPICAL UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY VOLT VOLTAGE AT MAX POWER VOLTAGE AT OPEN CIRCUIT WATT NEMA 3R, RAIN TIGHT PV1 PV2 PV3 PV4 PV5 PV6VICINITY ABBREVIATIONS ELECTRICAL NOTES GENERAL NOTES AHJ: UTILITY: LICENSES HIC: 198351 ELEC: 8209-EL-A1 COVER SHEET SITE PLAN ARRAY DETAIL STRUCTURAL VIEWS SINGLE LINE LABEL SET 1.WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 2.EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 3.A NATIONALLY-RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4.CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B) 5.DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 6.ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 7.MODULE FRAMES SHALL BE GROUNDED AT THE UL-LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 8.ALL EXPOSED METAL PARTS (MODULE FRAMES, RAIL, BOXES, ETC.) SHALL BE GROUNDED USING UL LISTED LAY-IN LUGS LISTED FOR THE PURPOSE. POSTS SHALL BE MADE ELECTRICALLY CONTINUOUS WITH ATTACHED RAIL. 9.MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS AND GROUNDED AT THE MAIN ELECTRIC PANEL. 10.THE DC GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED ACCORDING TO ART. 250.166(B) & 690.47. 1.THIS SYSTEM IS GRID-INTERTIED VIA A UL-LISTED POWER-CONDITIONING INVERTER. 2.THIS SYSTEM HAS NO BATTERIES, NO UPS. 3.ALL INVERTERS AND ARRAYS ARE NEGATIVELY GROUNDED. 4.SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. INDEX NATIONALGRID N T S A AC BLDG CONC C D DC EGC (E) EMT GALV GEC GND HDG I Imp INVS Isc kVA kW LBW MIN (N) NEC NIC NTS OC P PL PV PVC S SCH SS SSD STC SWH TYP UON UPS V Vmp Voc W 3R AMPERE ALTERNATING CURRENT BUILDING CONCRETE COMBINER BOX DISTRIBUTION PANEL DIRECT CURRENT EQUIPMENT GROUNDING CONDUCTOR EXISTING ELECTRICAL METALLIC TUBING GALVANIZED GROUNDING ELECTRODE CONDUCTOR GROUND HOT DIPPED GALVANIZED CURRENT CURRENT AT MAX POWER INVERTERS SHORT CIRCUIT CURRENT KILOVOLT AMPERE KILOWATT LOAD BEARING WALL MINIMUM NEW NATIONAL ELECTRIC CODE NOT IN CONTRACT NOT TO SCALE ON CENTER PANEL BOARD PROPERTY LINES PHOTOVOLTAIC POLYVINYL CHLORIDE SUBPANEL SCHEDULE STAINLESS STEEL SEE STRUCTURAL DIAGRAMS STANDARD TESTING CONDITIONS SOLAR WATER HEATER TYPICAL UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY VOLT VOLTAGE AT MAX POWER VOLTAGE AT OPEN CIRCUIT WATT NEMA 3R, RAIN TIGHT PV1 PV2 PV3 PV4 PV5 PV6VICINITY ABBREVIATIONS ELECTRICAL NOTES GENERAL NOTES APPLICABLE CODES 2015 IBC 2023 NEC AHJ: UTILITY: EMPOWER ENERGY SOLUTION 30 OLD KINGS HWY S # 1001 , DARIEN CT, 06820-4551 LICENSES COVER SHEET SITE PLAN ARRAY DETAIL STRUCTURAL VIEWS SINGLE LINE LABEL SET 1.WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 2.EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 3.A NATIONALLY-RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4.CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B) 5.DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 6.ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 7.MODULE FRAMES SHALL BE GROUNDED AT THE UL-LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 8.ALL EXPOSED METAL PARTS (MODULE FRAMES, RAIL, BOXES, ETC.) SHALL BE GROUNDED USING UL LISTED LAY-IN LUGS LISTED FOR THE PURPOSE. POSTS SHALL BE MADE ELECTRICALLY CONTINUOUS WITH ATTACHED RAIL. 9.MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS AND GROUNDED AT THE MAIN ELECTRIC PANEL. 10.THE DC GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED ACCORDING TO ART. 250.166(B) & 690.47. 1.THIS SYSTEM IS GRID-INTERTIED VIA A UL-LISTED POWER-CONDITIONING INVERTER. 2.THIS SYSTEM HAS NO BATTERIES, NO UPS. 3.ALL INVERTERS AND ARRAYS ARE NEGATIVELY GROUNDED. 4.SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. INDEX NATIONALGRID N T S MAGINNIS, WILLIAM T MAGINNIS RESIDENCE 79 GOLDEN DR LOT 12 L12 NORTHAMPTON, MA.01062 (413) 320-7519 RACKING: IRONRIDGE XR-10 JOB NUMBER: 2375 UTILITY: NATIONALGRID OWNER:DESCRIPTION:DESIGNED BY: REV:DATE: 29/07/2023 PAGE NAME: PAGE: HR INVERTER: (1 ) SOLAREDGE INVERTER SE5000H-US (5.00 KW) 5.00 kW AC COVER SHEET PV1REVIEW BY: MS MAGINNIS, WILLIAM T MAGINNIS RESIDENCE 79 GOLDEN DR LOT 12 L12 NORTHAMPTON, MA.01062 (413) 320-7519 5.925 kW DC ROOF SOLAR SYSTEMRACKING: IRONRIDGE XR-10 JOB NUMBER: 2375 UTILITY: NATIONALGRID UTILITY ACCT #: 01668-87010 OWNER:DESCRIPTION:DESIGNED BY: REV:DATE: 29/07/2023 PAGE NAME: PAGE: HR INVERTER: (1 ) SOLAREDGE INVERTER SE5000H-US (5.00 KW) 5.00 kW AC COVER SHEET PV1REVIEW BY: MS..\..\Pictures\for new templete.png Signed 8/01/2023 FOH DRIVEWAY79 GOLDEN DR LOT 12 L12 3' 1'-6" M INV AC MSP B LEGEND M INV AC MSP B D LC μ UTILITY METER INVERTER AC DISCONNECT MAIN SERVICE PANEL DC JUNCTION BOX MONITORING UNIT DISTRIBUTION PANEL LOAD CENTER CONDUIT FENCE SCALE: 1"=15' N S EW ATS AUTOMATIC TRANSFER SWITCH MAGINNIS, WILLIAM T MAGINNIS RESIDENCE 79 GOLDEN DR LOT 12 L12 NORTHAMPTON, MA.01062 (413) 320-7519 RACKING: IRONRIDGE XR-10 JOB NUMBER: 2375 UTILITY: NATIONALGRID OWNER:DESCRIPTION:DESIGNED BY: REV:DATE: 29/07/2023 PAGE NAME: PAGE: HR INVERTER: (1 ) SOLAREDGE INVERTER SE5000H-US (5.00 KW) 5.00 kW AC SITE PLAN PV2REVIEW BY: MS..\..\Pictures\for new templete.png 5.925 kW DC ROOF SOLAR SYSTEMUTILITY ACCT #: 01668-87010 MODULES: (15) CANADIAN CS6R-395MS-HL Signed 8/01/2023 3' 1'-6" M INV AC MSP B LEGEND ROOF RAFTERS RAIL MOUNT OBSTRUCTION ROOF LEAD SIGN OFF: TOTAL PENETRATION COUNT 50 MP1 RAFTER PROFILE RAFTER SPACING C.J. SPACING ATTACHMENT SPACING ROOF PITCH ARRAY PITCH ROOF AZIMUTH ARRAY AZIMUTH ROOF SURFACE TYPE STORIES 2X6 16" 16" 48" 22° 22° 174° 174° ASPHALT SHINGLE 2 JUNCTION BOX CONDUIT AC DISCONNECT UTILITY METER MAIN SERVICE PANEL MP1 (15) MODULES SCALE: 1" = 10' INVERTER MAGINNIS, WILLIAM T MAGINNIS RESIDENCE 79 GOLDEN DR LOT 12 L12 NORTHAMPTON, MA.01062 (413) 320-7519 RACKING: IRONRIDGE XR-10 JOB NUMBER: 2375 UTILITY: NATIONALGRID OWNER:DESCRIPTION:DESIGNED BY: REV:DATE: 29/07/2023 PAGE NAME: PAGE: HR INVERTER: (1 ) SOLAREDGE INVERTER SE5000H-US (5.00 KW) 5.00 kW AC ARRAY DETAIL PV3 ARRAY DETAIL PV3REVIEW BY: MS..\..\Pictures\for new templete.png N S EW 5.925 kW DC ROOF SOLAR SYSTEMUTILITY ACCT #: 01668-87010 MODULES: (15) CANADIAN CS6R-395MS-HL ROOF AREA, (sq. ft) MODULES AREA, (sq. ft) ROOF AREA COVERED BY MODULES (%) 315 13 2387 Signed 8/01/2023 PAGE NAME: PV4 STANDOFF SCALE NTSS1 SOLAR MODULE RAIL L-FOOT QMSE-LAG SHINGLE COMPOSITE SHINGLE 5"X 5 16" - LAG 2.5" MIN. EMBEDMENT PER SCREW 2X6 NOMINAL MAGINNIS, WILLIAM T MAGINNIS RESIDENCE 79 GOLDEN DR LOT 12 L12 NORTHAMPTON, MA.01062 (413) 320-7519 RACKING: IRONRIDGE XR-10 JOB NUMBER: 2375 UTILITY: NATIONALGRID OWNER:DESCRIPTION:DESIGNED BY: REV:DATE: 29/07/2023 PAGE: HR INVERTER: (1 ) SOLAREDGE INVERTER SE5000H-US (5.00 KW) 5.00 kW AC STRUCTURAL VIEWS REVIEW BY: MS..\..\Pictures\for new templete.png RAFTERS: 2X6 @ 16" O.C. MAX SPAN ~ 14' 6" 14'1' - 4" 15'-4" S1 NTS MP1 SIDE VIEW 1'-6" 2'-7" 5.925 kW DC ROOF SOLAR SYSTEMUTILITY ACCT #: 01668-87010 MODULES: (15) CANADIAN CS6R-395MS-HL Signed 8/01/2023 BREAKER FUSE SWITCH EARTH GROUND GEC EGC 1 AWG #6, THWN-2 AWG #8, THWN-2, EGC/GEC CONDUIT, 3/4" EMT AWG #6, THWN-2 AWG #10, THWN-2, EGC/GEC CONDUIT, 3/4" EMT AWG #10, THWN-2 AWG #10, THWN-2, EGC/GEC CONDUIT, 3/4" EMT AWG #10, PV WIRE AWG #10, THWN-2, EGC CONDUIT, 3/4" EMT ELEC. LEAD SIGN OFF: WIRE SCHEDULE 1 2 3 4 120/240V SINGLE PHASE OVERHEAD UTILITY SERVICE METER 91295314 200A/2P (E) LOADS 200A SQUARE D MSPGROUND ELECTRODE LINE SIDE TAP LINE LOAD 30A (N) 60A AC DISCONNECT - FUSIBLE, LOCKABLE - 30A FUSES 2 (N) SOLAREDGE INVERTER SE5000H-US (N) SOLADECK JUNCTION BOX - UNFUSED -GROUNDED (N) (15) CANADIAN CS6R-395MS-HL 395W PV MODULES (15) SOLAREDGE P370 POWER OPTIMIZERS 1 BRANCH OF 15 43 INVERTER OUTPUT CURRENT(A)= INVERTER BACKFEED (A)= MSP RATING (A)= MAIN BREAKER RATING (A)= MAX BACKFEED (A)= TIE IN: 21 26 200 200 40 LST MAGINNIS, WILLIAM T MAGINNIS RESIDENCE 79 GOLDEN DR LOT 12 L12 NORTHAMPTON, MA.01062 (413) 320-7519 RACKING: IRONRIDGE XR-10 JOB NUMBER: 2375 UTILITY: NATIONALGRID OWNER:DESCRIPTION:DESIGNED BY: REV:DATE: 29/07/2023 PAGE NAME: PAGE: HR INVERTER: (1 ) SOLAREDGE INVERTER SE5000H-US (5.00 KW) 5.00 kW AC SINGLE LINE PV5REVIEW BY: MS..\..\Pictures\for new templete.png 5.925 kW DC ROOF SOLAR SYSTEMUTILITY ACCT #: 01668-87010 MODULES: (15) CANADIAN CS6R-395MS-HL MAGINNIS, WILLIAM T MAGINNIS RESIDENCE 79 GOLDEN DR LOT 12 L12 NORTHAMPTON, MA.01062 (413) 320-7519 RACKING: IRONRIDGE XR-10 JOB NUMBER: 2375 UTILITY: NATIONALGRID OWNER:DESCRIPTION:DESIGNED BY: REV:DATE: 29/07/2023 PAGE NAME: PAGE: HR INVERTER: (1 ) SOLAREDGE INVERTER SE5000H-US (5.00 KW) 5.00 kW AC LABEL SETS PV6REVIEW BY: MS..\..\Pictures\for new templete.png TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL WARNING PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZERD IN THE ARRAY SOLAR ELECTRIC PV PANELS 1 2 3 4 5 9 6 7 8 10 Combiner Box/circuits/Conduit Combiner Box/Enclosures/EMT Enclosures /Main Service Disconnect/ Breaker Panel/Pull Boxes SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/2" - 1'.0" ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING NEC 706.15(C)(4) and NEC 690.13(B) Roll: 596-00878 / 10-Pk: 596-00893 Metal 5-Pk: 596-00921 NEC 110.27(C) & OSHA 1910.145(f)(7) Roll: 596-00499 / 10-Pk: 596-00664 Metal 5-Pk: 596-00832 IFC 605.11.3.1(1) & 690.56(C) Roll: 596-00885 / 10-Pk: 596-00888 AC Disconnection/Point Of Interconnection ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT !!! DC Disconnect / Breaker / Recombiner Box DC Disconnect / Breaker / Recombiner Box NEC 690.13(B) / Roll: 596-00879 10-Pk: 596-00894 / Metal 5-Pk: 596-00920 PHOTOVOLTAIC DC DISCONNECT 11 NEC 690.13(B) Roll: 596-00238 / 10-Pk: 596-00854 RATED AC OPERATING CURRENT: DC Disconnect / Breaker / Recombiner Box MAX RATED AC OPERATING CURRENT: RATED AC OPERATING VOLTAGE: MAX RATED AC OPERATING VOLTAGE: RATED SHORT CIRCUIT CURRENT: MAXIMUM SYSTEM VOLTAGE: FOR MARKING DC BACKUP SYSTEMS / Roll: 596-00240 MAXIMUM DC VOLAGE OF PV SYSTEM NEC 690.53 / Roll: 596-01001 / 10-Pk: 596-01009 DC Disconnect / Breaker / Recombiner Box SOLAR PV DC CIRCUIT NEC 690.31(O)(2) / Roll: 596-00998 / 10-Pk: 596-01006 PHOTOVOLTAIC POWER SOURCE NEC 690.31(D)(2) / Roll: 596-00999 / 10-Pk: 596-01007 EMT / Conduit Raceways Combiner Box/circuits/Conduit Combiner Box/Enclosures/EMT Enclosures /Main Service Disconnect/ Breaker Panel/Pull Boxes INVERTER THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT WARNING! NEC 690.31(E) / Roll: 596-09323 10-Pk: 596-09324 / Metal 5-Pk: 596-00924 PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: NEC 690.54 / Roll: 596-00892 / 10-Pk: 596-00882 Inverter / Breaker Panel / Pull Boxes / AC disconnect /Breaker/Points Of Connection WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM ! NEC 705.12(D)(3) & NEC 690.59 / Roll: 596-00495 10-Pk: 596-09665 / Metal 5-Pk: 596-00833 Production / Net Meter (Bi-directional) /Main Service Disconnect ENGINEERING STAMP (if appl.) SCALE 1/4" - 1'.0" 5.925 kW DC ROOF SOLAR SYSTEMUTILITY ACCT #: 01668-87010 MODULES: (15) CANADIAN CS6R-395MS-HL MAGINNIS, WILLIAM T MAGINNIS RESIDENCE 79 GOLDEN DR LOT 12 L12 NORTHAMPTON, MA.01062 (413) 320-7519 RACKING: IRONRIDGE XR-10 JOB NUMBER: 2375 UTILITY: NATIONALGRID OWNER:DESCRIPTION:DESIGNED BY: REV:DATE: 29/07/2023 PAGE NAME: PAGE: HR INVERTER: (1 ) SOLAREDGE INVERTER SE5000H-US (5.00 KW) 5.00 kW AC LABEL SETS PV7REVIEW BY: MS..\..\Pictures\for new templete.png AC Disconnect / Breaker / Points of Connection SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" SCALE 1/4" - 1'.0" Main Service Disconnect ENERGY STORAGE SYSTEMS ENGINEERING STAMP (if appl.) SCALE 1/4" - 1'.0" PHOTOVOLTAIC AC DISCONNECT NEC 705.12(B)(3)(3) / Roll: 596-01000 10-Pk: 596-01008 THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING! AC Disconnect / Breaker / Points of Connection SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUITS WARNING! NEC 690.13(B) / Roll: 596-00237 / 10-Pk: 596-00853 NEC 710.15(C) & 692.9 (C) / Roll: 596-00591 10-Pk: 596-00699 / Metal 5-Pk: 596-00837 DO NOT DISCONNECT UNDER LOAD NEC 690.15 (B) & NEC 690.33(D)(2) Roll: 596-00244 / 10-Pk: 596-00671 CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEED ! NEC 705.12(D) & NEC 690.59 Roll: 596-00587 / 10-Pk: 596-00666 Metal 5-Pk: 596-00834 WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. ! Main Service Disconnect Main Service Disconnect Main Service Disconnect NEC 705.12 (B)(3)(2) / Roll: 596-00883 10-Pk: 596-00884 / Metal 5-Pk: 596-00917 MAIN PHOVOLTAIC SYSTEM DISCONNECT NEC 690.13(B) / Roll: 596-00243 10-Pk: 596-00675 / Metal 5-Pk: 596-00860 Main Service Disconnect/ Utility Meter NOMINAL ESS AC VOLTAGE: NOMINAL ESS DC VOLTAGE: AVAILABLE FAULT CURRENT DERIVED FROM THE ESS: DATE CALCULATION PERFORMED: NEC 690.15 (B) & NEC 690.33(D)(2) Roll: 596-00244 / 10-Pk: 596-00671 ENERGY STORAGE SYSTEMS WARNING FUEL CELL POWER SYSTEM CONTAINS ENERGY STORAGE DEVICES ! NEC 692.56 / Roll: 596-01002 / 10-Pk: 596-01010 NOTES: ANSI Z535.4-2011 Product Safety Signs and Labels, provides guidelines for suitable font sizes, words, colors, symbols, and location requirements for labels. NEC 110.21(B)(1) The label shall be of sufficient durability to withstand the environment involved. NEC 110.21(B)(3) Adhesive fastened signs may be acceptable if properly adhered. Vinyl signs shall be weather resistant. IFC 605.11.1.3 Plaques and Directories at the Service Equipment (MSP) and the Location of All System Disconnects per NEC 705.10 & 690.56(A)(B)Roll:558-00350 12 13 14 15 16 17 18 19 20 5.925 kW DC ROOF SOLAR SYSTEMUTILITY ACCT #: 01668-87010 MODULES: (15) CANADIAN CS6R-395MS-HL M INV AC MSP B CS6R-380|385|390|395|400|405MS-HL 380 W ~ 405 W MORE POWER MORE RELIABLE Comprehensive LID / LeTID mitigation technology, up to 50% lower degradation Module power up to 405 W 405 W Minimizes micro-crack impacts Better shading tolerance Lower LCOE & system cost Take-e-way Heavy snow load up to 7000 Pa, wind load up to 5000 Pa* HiKu6 (All-Black) ALL BLACK MONO PERC products you order or use. Please contact your local Canadian Solar sales representative in which the products will be used. PRODUCT CERTIFICATES* ISO 9001:2015 / Quality management system ISO 14001:2015 / Standards for environmental management system ISO 45001: 2018 / International standards for occupational health & safety MANAGEMENT SYSTEM CERTIFICATES* Years Years Industry Leading Product Warranty on Materials and Workmanship* Linear Power Performance Warranty* 1st year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% *Subject to the terms and conditions contained in the applicable Canadian Solar Limited Warranty Statement. Also this 25-year limited product warranty is available only for prod- ucts installed and operating on residential rooftops in certain regions. Preliminary Technical Information Sheet * Pending testing confirmation. For detailed information, please refer to the Installation Manual. is committed to providing high quality solar photovoltaic modules, solar energy and battery storage solutions to customers. The company was recognized as the No. 1 module supplier for quality and performance/price ratio in the IHS Module Customer Insight Survey. Over the past 20 years, it has successfully delivered over 67 GW of premium-quality solar modules across the world. CSI SOLAR (USA) CO., LTD. CSI SOLAR (USA) CO., LTD. 1350 Treat Blvd. Suite 500, Walnut Creek, CA 9459 , USA | www.csisolar.com/na | service.ca@csisolar.com PARTNER SECTION ENGINEERING DRAWING (mm)CS6R-400MS / I-V CURVES products due to the on-going innovation and product enhancement. CSI Solar Co., Ltd. reserves the right to make necessary adjustment to the information described herein at any time without further notice. have professional skills and please carefully read the safety and installation instructions before using our PV modules. V A V A 1000 W/m2 800 W/m2 600 W/m2 400 W/m2 200 W/m2 5°C 25°C 45°C 65°C MECHANICAL DATA Data Cell Type Mono-crystalline Cell Arrangement 108 [2 X (9 X 6) ] 1722 x 1134 x 35 mm (67.8 x 44.6 x 1.38in)Dimensions Weight Front Cover 3.2 mm tempered glass with anti- Frame Anodized aluminium alloy, IP68, 3 bypass diodes Cable 4 mm2 (IEC), 12 AWG (UL) Connector T6 or MC4 series Cable Length (Including Connector)1550 mm (61.0 in) (+) / 850 mm (33.5 in) (-)* Per Pallet 30 pieces Per Container (40' HQ)780 pieces * For detailed information, please contact your local Canadian Solar sales and technical representatives. 14 13 12 11 10 9 8 6 5 4 3 2 1 0 5 10 15 20 25 30 35 40 45 50 55 60 5 10 15 20 25 30 35 40 45 50 55 60 0 ~ + 10 W 14 13 12 11 10 9 8 6 5 4 3 2 1 0 ELECTRICAL DATA | STC* CS6R 380MS 385MS 390MS 395MS 400MS 405MS 380 W 385 W 390 W 395 W 400 W 405 W Opt. Operating Voltage (Vmp)30.0 V 30.2 V 30.4 V 30.6 V 30.8 V 31.0 V Opt. Operating Current (Imp)12.69 A 12.84 A 12.91 A 12.99 A Open Circuit Voltage (Voc)36.0 V 36.2 V 36.4 V 36.6 V 36.8 V Short Circuit Current (Isc)13.55 A 13.63 A 13.85 A 13.93 A 19.5%20.0%20.2%20.5% Operating Temperature -40°C ~ +85°C 1500V (IEC/UL) or 1000V (IEC/UL) Module Fire Performance 25 A Class A Power Tolerance * Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell tempe- rature of 25°C. ELECTRICAL DATA | NMOT* CS6R 380MS 385MS 390MS 395MS 400MS 405MS 284 W 288 W 291 W 295 W 299 W 303 W Opt. Operating Voltage (Vmp)28.1 V 28.3 V 28.4 V 28.6 V 28.8 V 29.0 V Opt. Operating Current (Imp)10.12 A 10.19 A 10.26 A 10.33 A 10.39 A 10.45 A Open Circuit Voltage (Voc)33.9 V 34.1 V 34.2 V 34.4 V 34.6 V Short Circuit Current (Isc)10.91 A 10.98 A 11.05 A 11.11 A 11.23 A * Under Nominal Module Operating Temperature (NMOT), irradiance of 800 W/m2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. TEMPERATURE CHARACTERISTICS Data -0.34 % / °C -0.26 % / °C 0.05 % / °C Nominal Module Operating Temperature 42 ± 3°C CSI SOLAR (USA) CO., LTD.June 2022 | All rights reserved | PV Module Product Datasheet v1.5C25_F23_J2_NA Rear View Mounting Hole Frame Cross Section A-A R149 35 35A-A A I A A 1134 172214009901084 35 80 808-14x9 Mounting Hole 6-5 Grounding Hole INVERTERSsolaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Fixed voltage inverter for longer strings UL1741 SA certified, for CPUC Rule 21 grid compliance Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 Small, lightweight, and easy to install both outdoors or indoors Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEARWARRANTY MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)----Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(3) Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14-6 AWG 1'' Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1-2 strings / 14-6 AWG 1'' Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(4)˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4 . For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box (4) Full power up to at least 50˚C / 122˚F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 01/2020/V01/ENG NAM. Subject to change without notice. How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills solaredge.com Power Optimizer For Residential Installations S440 / S500 / S500B / S650B Enabling PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading Faster installations with simplified cable management and easy assembly using a single bolt Flexible system design for maximum space utilization Compatible with bifacial PV modules POWER OPTIMIZER 25 YEAR WARRANTY * Functionality subject to inverter model and firmware version © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February 16, 2023 DS-000091-ENG. Subject to change without notice. Power Optimizer For Residential Installations S440 / S500 / S500B / S650B S440 S500 S500B S650B UNIT INPUT Rated Input DC Power(1) 440 500 650 W Absolute Maximum Input Voltage (Voc) 60 125 85 Vdc MPPT Operating Range 8 – 60 12.5 – 105 12.5 - 85 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERTION Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE(2) EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2018-12 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 155 x 30 129 x 165 x 45 mm Weight 720 790 gr Input Connector MC4(3) Input Wire Length 0.1 m Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 m Operating Temperature Range(4) -40 to +85 ˚C Protection Rating IP68 Relative Humidity 0 – 100 % (1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed. (2) For details about CE compliance, see Declaration of Conformity – CE. (3) For other connector types please contact SolarEdge. (4) Power de-rating is applied for ambient temperatures above +85°C for S440 and S500, and for ambient temperatures above +75°C for S500B. Refer to the Power Optimizers Temperature De-Rating Technical Note for details. PV System Design Using a SolarEdge Inverter(5) SolarEdge Home Wave Inverter Single Phase SolarEdge Home Short String Inverter Three Phase Three Phase for 230/400V Grid Three Phase for 277/480V Grid Minimum String Length (Power Optimizers) S440, S500 8 9 16 18 S500B, S650B 6 8 14 Maximum String Length (Power Optimizers) 25 20 50 Maximum Continuous Power per String 5700 5625 11250 12750 W Maximum Allowed Connected Power per String (Permitted only when the power difference between strings is less than 2,000W) See(6) See(6) 13500 15000 W Parallel Strings of Different Lengths or Orientations Yes (5) It is not allowed to mix S-series and P-series Power Optimizers in new installations. (6) If the inverter’s rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to Application Note: Single String Design Guidelines. S440, S500 (Flat Bracket) S500B, S650B (Bent Bracket)