Loading...
355652_Barry Gruber_PERMIT_PLANSET_updated-signed (1)PV-1FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:355652DESIGNED BY:N.W.CLIENT:BARRY GRUBER128 BROOKSIDE CIR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)PHONE: (203) 883-2779EMAIL: BMGRUBER@GMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 19 X 395 = 7.505 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 19 X CANADIAN SOLAR:CS3N-395MSOPTIMIZERS: 19 X SOLAREDGE S440INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:7/18/2023---------THIS PROJECT COMPLIES WITH THE FOLLOWING:2015 INTERNATIONAL BUILDING CODE2015 INTERNATIONAL RESIDENTIAL CODE2018 INTERNATIONAL MECHANICAL CODE2018 INTERNATIONAL PLUMBING CODE2018 INTERNATIONAL FUEL GAS CODE2018 INTERNATIONAL ENERGY CONSERVATION CODE2015 INTERNATIONAL EXISTING BUILDING CODE2018 INTERNATIONAL SWIMMING POOL AND SPA CODE2020 NATIONAL ELECTRICAL CODEAS ADOPTED BY CITY OF NORTHAMPTON (MA)SITE LOCATIONCODES:VICINITY MAP:TABLE OF CONTENTS:CONSTRUCTION NOTES:ROOF MOUNT PHOTOVOLTAIC SYSTEMPV-1SITE LOCATIONPV-2SITE PLANPV-2AROOF PLAN WITH MODULES LAYOUTPV-2BROOF AND STRUCTURAL TABLESPV-3MOUNTING DETAILSPV-4THREE LINE DIAGRAMPV-5CONDUCTOR CALCULATIONSPV-6EQUIPMENT & SERVICE LISTPV-7LABELSPV-7ASITE PLACARDPV-8OPTIMIZER CHARTPV-9SAFETY PLANPV-10SAFETY PLANAPPENDIXMANUFACTURER SPECIFICATION SHEETSCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS ANDARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENTPOSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY AREMOUNTED.MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION INACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PERSECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANYEXCAVATION TAKING PLACEPHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROMDC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A).SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITHREQUIREMENTS OF ART. 690 OF THE 2020 NECTHE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFERUTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEMSOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDSINSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITATTACHED TO THE ROOF USING CONDUIT MOUNT.SITE LOCATIONGREG ALBRIGHT UMJBMSPACINVSITE PLANSCALE: 1/24" = 1'-0"1ROOF LINEPROPERTY LINEDRIVEWAYFENCE/GATE(E) MAIN SERVICE PANEL(N) 19 CANADIAN SOLAR: CS3N-395MS(E) UTILITY METER(N) JUNCTION BOX(N) SOLAREDGE SE6000H-USRGM [SI1]INVERTER WITH RAPID SHUTDOWN(N) ACCESSIBLE AND LOCKABLE ACDISCONNECT EATON DG222URB (OREQUIVALENT)PV-2FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:355652DESIGNED BY:N.W.CLIENT:BARRY GRUBER128 BROOKSIDE CIR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)PHONE: (203) 883-2779EMAIL: BMGRUBER@GMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 19 X 395 = 7.505 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 19 X CANADIAN SOLAR:CS3N-395MSOPTIMIZERS: 19 X SOLAREDGE S440INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:7/18/2023---------ROOF AREA: 1133 SQ FTSITE PLANLEGEND:CHIMNEYPIPE VENTMODULESCONDUITSETBACKAC DISCONNECTUTILITY METERJUNCTION BOXINVERTERMAIN SERVICEPANELACUMJBINVMSPGREG ALBRIGHTBROOKSIDE CIR123'-4"106'-5"1 3 3 ' - 2 "162'-0"34'-11"10'-1"62'-11" 128'-9" UMJBMSPACINV PV-2AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:355652DESIGNED BY:N.W.CLIENT:BARRY GRUBER128 BROOKSIDE CIR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)PHONE: (203) 883-2779EMAIL: BMGRUBER@GMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 19 X 395 = 7.505 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 19 X CANADIAN SOLAR:CS3N-395MSOPTIMIZERS: 19 X SOLAREDGE S440INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:7/18/2023---------ROOF PLANSCALE: 1/8" = 1'-0"1(N) SOLAREDGE SE6000H-USRGM [SI1]INVERTERNOTES:1.EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS2.ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES3.JUNCTION BOX IS MOUNTED TO THE RAIL.ROOF AREA: 1133 SQ FTROOF PLAN WITH MODULES LAYOUTUTILITY METERLEGEND:OBSTRUCTIONPIPE VENT19 CANADIAN SOLAR:CS3N-395MSCONDUITSETBACKMSP AC VISIBLELOCKABLELABELED ACDISCONNECTMSPJUNCTIONBOXINVINVERTER JB UM GREG ALBRIGHTTOTAL ROOF AREA: 1133 SQ FTTOTAL ARRAY AREA: 415.81 SQ FTARRAY COVERAGE: 36.70%SYSTEM DISTRIBUTED WEIGHT: 2.36 LBSROCKIT COMP SLIDE POINT-LOAD: 31.63 LBS PV-2BFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:355652DESIGNED BY:N.W.CLIENT:BARRY GRUBER128 BROOKSIDE CIR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)PHONE: (203) 883-2779EMAIL: BMGRUBER@GMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 19 X 395 = 7.505 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 19 X CANADIAN SOLAR:CS3N-395MSOPTIMIZERS: 19 X SOLAREDGE S440INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:7/18/2023---------ROOF DETAILSGREG ALBRIGHTROOF AREA STATEMENTROOFMODULE QUANTITYROOF PITCHARRAY PITCHAZIMUTHROOF AREAARRAY AREAROOF 1152323252578.4 SQ FT328.27 SQ FTROOF 24232372554.7 SQ FT87.54 SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FT-------------------- SQ FT SQ FTROOF DETAILS:TOTAL ROOF AREA: 1133 SQ FTTOTAL ARRAY AREA: 415.81 SQFTARRAY COVERAGE: 36.70%SYSTEM DISTRIBUTED WEIGHT: 2.36 LBSROCKIT COMP SLIDE POINT-LOAD: 31.63 LBS ROCKIT MOUNTVARIESROOF SURFACESKIRTCANADIAN SOLAR:CS3N-395MSROCKIT MOUNTROOF MEMBRANECANADIAN SOLAR:CS3N-395MSROCKIT MOUNTROOF MEMBRANE2X4 TRUSS @ 24" O.C.CANADIAN SOLAR: CS3N-395MS3" MIN.6" MAX.5/16" STAINLESS STEEL LAG BOLT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER2.5" MIN. EMBED.2.5" MIN. EMBED.2.5" MIN. EMBED.5/16" STAINLESS STEEL LAG BOLT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER5/16" STAINLESS STEEL LAG BOLT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHERTABLE 1 - ARRAY INSTALLATIONROOFPITCHROOFING TYPEATTACHMENT TYPEFRAMING TYPE1MAX UNBRACEDLENGTH(FT.)1RAFTER/TRUSSSISTERINGPENETRATIONPATTERN2MAXATTACHMENTSPACING(IN.)2MAX RAILOVERHANG(IN.)3ROOF 1 23 COMP SHINGLE ECOFASTEN ROCKIT COMP SLIDE2X4 TRUSS @ 24" OC6.00'NOT REQ'DSTAGGERED 72" OC24"ROOF 2 23 COMP SHINGLE ECOFASTEN ROCKIT COMP SLIDE2X4 TRUSS @ 24" OC6.00'NOT REQ'DSTAGGERED 72" OC24"1. CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION. IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS, NOTIFY ENGINEER OF RECORD IMMEDIATELY.2. WHERE COLLAR TIES OR RAFTER SUPPORTS EXIST, CONTRACTOR SHALL USE RAFTERS WITH COLLAR TIES AS ATTACHMENT POINTS.3. WHERE APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS.ATTACHMENT DETAILScale: NTSSOLAR PV ARRAY SECTION VIEWScale: NTSPV-3FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:355652DESIGNED BY:N.W.CLIENT:BARRY GRUBER128 BROOKSIDE CIR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)PHONE: (203) 883-2779EMAIL: BMGRUBER@GMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 19 X 395 = 7.505 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 19 X CANADIAN SOLAR:CS3N-395MSOPTIMIZERS: 19 X SOLAREDGE S440INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:7/18/2023---------MOUNTING DETAILSGREG ALBRIGHTSTAGGERED DETAILFor Illustration purposes onlySTACKED DETAILFor Illustration purposes only 4 - #10 AWG, PV WIRE1 - #6 AWG IN FREE AIR OR#10 AWG MUST BE IN EMT CONDUITSTRING-2STRING-1JUNCTIONBOXSOLAREDGE S440 POWER OPTIMIZERSSOLAREDGE S440 POWER OPTIMIZERS9 CANADIAN SOLAR: CS3N-395MS10 CANADIAN SOLAR:CS3N-395MS4 - #10 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" ORLARGER EMT CONDUITUM(E) 200A / 2P MAINBREAKER(TOP FED)(E) 200A RATEDMAIN SERVICE PANEL1PH, 120/240V 60HZ(E) UTILITYMETER(N) 35A / 2P PV BREAKERTO OTHER LOADSTO UTILITYOVERHEADFEED3 - #8 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) 60A RATEDACCESSIBLE AND LOCKABLEAC DISCONNECTEATON DG222URB (OREQUIVALENT) KNIFEBLADE, LOCKABLE,NEMA 3R, UL LISTED3 - #8 AWG, THWN-21 - #10 EGC, THWN-2IN 3/4" OR LARGER EMTCONDUIT(N) SOLAREDGESE6000H-USRGM [SI1]INVERTERACDCRAPIDSHUTDOWNSWITCHNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONSBACKFEED BREAKER SIZINGMAX. CONTINUOUS OUTPUT 25.00A @ 240V25.00X1.25=31.25AMPS35A BREAKER - OKSEE 705.12 OF 2020 NEC200X1.20=240240-200=40A ALLOWABLE BACKFEEDPV-4FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:355652DESIGNED BY:N.W.CLIENT:BARRY GRUBER128 BROOKSIDE CIR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)PHONE: (203) 883-2779EMAIL: BMGRUBER@GMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 19 X 395 = 7.505 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 19 X CANADIAN SOLAR:CS3N-395MSOPTIMIZERS: 19 X SOLAREDGE S440INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:7/18/2023---------THREE LINE DIAGRAMGREG ALBRIGHT PV-5FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:355652DESIGNED BY:N.W.CLIENT:BARRY GRUBER128 BROOKSIDE CIR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)PHONE: (203) 883-2779EMAIL: BMGRUBER@GMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 19 X 395 = 7.505 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 19 X CANADIAN SOLAR:CS3N-395MSOPTIMIZERS: 19 X SOLAREDGE S440INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:7/18/2023---------CONDUCTOR CALCULATIONSGREG ALBRIGHTWIRE SCHEDULERACEWAY#EQUIPMENTCONDUCTORQTY.AWGWIRESIZESTARTINGALLOWABLEAMPACITY @ 90°C310.15(B)(16)STARTINGCURRENTAPPLIED TOCONDUCTORSIN RACEWAYTEMPERATURECORRECTIONFACTOR310.15(B)(2)(a)ADJUSTMENTFACTOR FORMORE THAN 3CONDUCTORS310.15(B)(3)(a)ADJUSTEDCONDUCTORAMPACITY@ 90°CMAXIMUMCURRENTAPPLIED TOCONDUCTORSIN RACEWAY1DCMODULETOOPTIMIZER2104014.301140.0017.882DCOPTIMIZERTOJUNCTION BOX2104015.001140.0018.753DCJUNCTION BOXTOINVERTER4104015.0010.832.0018.754ACINVERTERTOAC DISCONNECT385525.001155.0031.255ACAC DISCONNECTTOPOI385525.001155.0031.25--------------------------------------------------------------------------------CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. MATERIAL LIST:PV-6FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:355652DESIGNED BY:N.W.CLIENT:BARRY GRUBER128 BROOKSIDE CIR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)PHONE: (203) 883-2779EMAIL: BMGRUBER@GMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 19 X 395 = 7.505 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 19 X CANADIAN SOLAR:CS3N-395MSOPTIMIZERS: 19 X SOLAREDGE S440INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:7/18/2023---------QTY.PARTPART #DESCRIPTION19MODULESPV-116-395CANADIAN SOLAR: CS3N-395MS19OPTIMIZERSOPT-130-440-2SOLAREDGE S440 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON1JUNCTION BOXRAC-260-049600VDC NEMA 3R UL LISTED JUNCTION BOX2ELECTRICAL ACCESSORIESEA-350-326STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE)2EQUIPMENT ACCESSORIESEA-350-327STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE)1INVERTERSINV-120-608SE6000H-US [SI1] RGM 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN1MONITORING EQUIPMENTME-180-502SOLAREDGE CELL MODEM1DISCONNECTSEE-321-06060A RATED 240VAC NEMA 3R UL LISTED31FITTINGS/ANCHORSRAC-265-002ROCKIT COMP SLIDE33FOOTINGS RAC-265-004"MFG: ECO FASTEN, ROCKIT COMP COUPLING AL BLK, MFG SKU: 2011021"31FITTINGS/ANCHORSRAC-265-002"MFG: ECO FASTEN, ROCKIT COMP SLIDE AL BLK, MFG SKU: 2011013"6FOOTINGS RAC-265-028"MFG: ECO FASTEN, SKIRT AL BLK 35MM & 40MM A80, MFG SKU: 2099012"4FITTINGS/ANCHORSRAC-265-031"MFG: ECO FASTEN, SKIRT END CAP PLS 35MM&40MM-A, MFG SKU: 2099035"19RAILSRAC-265-018"MFG: ECO FASTEN, FRAME MLPE MOUNT SS, MFG SKU: 4011012"31FLASHING 1RAC-265-001"MFG: ECO FASTEN, GF-1 FLASHING GLV BLK 8X10, MFG SKU: 3012020"OCPD SIZES:35A BREAKERSERVICE LIST:NONEEQUIPMENT & SERVICE LISTGREG ALBRIGHT NOTES:M690.13(B)MAIN PHOTOVOLTAICSYSTEM DISCONNECTTURN RAPIDSHUTDOWN SWITCH TOTHE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCE SHOCKHAZARD IN THE ARRAYIFC 605.11.3.1(1) & 690.56(C)SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNAC NEC 690.13(B)INVERTERDCSOLAR PV DC CIRCUITEVERY 10' ON CONDUIT AND ENCLOSURESSOLAR ELECTRICPV PANELS706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANEL!WARNINGSINGLE 120-VOLT SUPPLYDO NOT CONNECTMULTIWIRE BRANCH CIRCUITSNEC 710.15(C) & 692.9 (C)NEC 690.15 (B) & NEC 690.33(D)(2)DO NOT DISCONNECTUNDER LOADNEC 705.12(D) & NEC 690.59!CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDNEC 705.12(D) & NEC 690.59NEC 705.12(C) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGPOWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE.!WARNINGARC FLASH AND SHOCK HAZARDAPPROPRIATE PPE REQUIRED24 INCH3480 VAC42 INCH12 INCH1 INCHFLASH HAZARD BOUNDARYCAL/CM^2 FLASH HAZARD AT 18 INCHESSHOCK HAZARD WHEN COVER IS REMOVEDLIMITED APPROACHRESTRICTED APPROACH - 500 V CLASS 00 GLOVESPROHIBITED APPROACH - 500 V CLASS 00 GLOVESLOCATION:128 BROOKSIDE CIR,NORTHAMPTON, MA 01062PHOTOVOLTAICAC DISCONNECTPHOTOVOLTAIC AC DISCONNECTRATED AC OUTPUT CURRENT:NOMINAL OPERATING AC VOLTAGE:25.00A240V!WARNINGTHIS EQUIPMENT FED BYMULTIPLE SOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEED AMPACITY OF BUSBARNEC 690.54NEC 705.12(B)(3)(3)NEC 706.15(C) AND NEC 110.16PM NEC 705.12(D) & NEC 690.59!WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENTNEC 690.31(E)PHOTOVOLTAIC POWER SOURCEEVERY 10' ON CONDUIT AND ENCLOSURESNEC 690.31NEC 690.31(D)(2) NEC 690.13(B)PHOTOVOLTAICDC DISCONNECT706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHT NEC 690.53MAXIMUM DC VOLTAGEOF PV SYSTEMARRAYJ/BNEC 690.31(G)(3) & (4)706.15(C)(4) & 690.13(B)!WARNINGELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONNEC 110.27(C) & OSHA 1910.145(F)(7)!WARNINGTURN OFF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELRAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEM690.56(C)(3)MAXIMUM VOLTAGEMAXIMUM CIRCUIT CURRENTMAX DC-DC CONVERTEROUTPUT CURRENTVAA16.548015PV-7FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:355652DESIGNED BY:N.W.CLIENT:BARRY GRUBER128 BROOKSIDE CIR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)PHONE: (203) 883-2779EMAIL: BMGRUBER@GMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 19 X 395 = 7.505 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 19 X CANADIAN SOLAR:CS3N-395MSOPTIMIZERS: 19 X SOLAREDGE S440INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:7/18/2023---------LABELSGREG ALBRIGHT1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINEWORK.C.ARIAL FONT.3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED INTHE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENTWITH POP-RIVETS OR SCREWS JUNCTION BOX19 PV MODULESACCESSIBLE ANDLOCKABLE ACDISCONNECTUTILITY METERCAUTION:PV-7AFREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:355652DESIGNED BY:N.W.CLIENT:BARRY GRUBER128 BROOKSIDE CIR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)PHONE: (203) 883-2779EMAIL: BMGRUBER@GMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 19 X 395 = 7.505 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 19 X CANADIAN SOLAR:CS3N-395MSOPTIMIZERS: 19 X SOLAREDGE S440INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:7/18/2023---------1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON.2.ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C.AERIAL FONT.3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN.4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.NOTES:SITE PLACARDGREG ALBRIGHTWARNINGTURN OFF PHOTOVOLTAIC AC DISCONNECTPRIOR TO WORKING INSIDE PANELNBROOKSIDE CIRPOWER TO THIS BUILDING ISALSO SUPPLIED FROM THEFOLLOWING SOURCES WITHDISCONNECTS AS SHOWNMAIN SERVICE PANELINVERTER EQUIPPEDWITH RAPID SHUTDOWN UMJBMSPACINV12345678910 1-1011-2021-3031-4041-5051-60123456789101-1011-2021-3031-4041-5051-60PV-8FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:355652DESIGNED BY:N.W.CLIENT:BARRY GRUBER128 BROOKSIDE CIR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)PHONE: (203) 883-2779EMAIL: BMGRUBER@GMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 19 X 395 = 7.505 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 19 X CANADIAN SOLAR:CS3N-395MSOPTIMIZERS: 19 X SOLAREDGE S440INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:7/18/2023---------SOLAREDGE OPTIMIZER CHARTOPTIMIZER CHARTGREG ALBRIGHT UMJBMSPACINV BROOKSIDE CIR PV-9FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:355652DESIGNED BY:N.W.CLIENT:BARRY GRUBER128 BROOKSIDE CIR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)PHONE: (203) 883-2779EMAIL: BMGRUBER@GMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 19 X 395 = 7.505 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 19 X CANADIAN SOLAR:CS3N-395MSOPTIMIZERS: 19 X SOLAREDGE S440INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:7/18/2023---------SAFETY PLANGREG ALBRIGHTSAFETY PLANMARK UP KEYINSTRUCTIONS:1.USE SYMBOLS IN KEY TO MARK UP THIS SHEET.2.SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THEPRE-PLAN3.DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ONTHE JHA SHEETINCIDENT REPORTING:INJURIES - CALL INJURY HOTLINE(855) 400-7233*If injury is life threatening, call 911 first THEN the Injury HotlineNON-INJURIES - USE MOBILE INCIDENT REPORTING(Auto, Property Damage, Near Miss)NEAREST OCCUPATIONAL/INDUSTRIAL CLINIC:NAME: _______________________________________________ADDRESS: ___________________________________________NEAREST HOSPITAL:NAME:_______________________________________________ADDRESS: ___________________________________________SAFETY COACH CONTACT INFORMATION:NAME: _______________________________________________PHONE NUMBER: _____________________________________ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN ANDSIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THEPLAN FOR WORKING SAFELY. NAME SIGNATURE__________ __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ ________________DATE: ______________ TIME:___________________________PERMANENT ANCHORTEMPORARY ANCHORINSTALLER LADDERJUNCTION / COMBINER BOXSTUB-OUTSKYLIGHTNO LADDER ACCESS (STEEPGRADE OR GROUND LEVELOBSTRUCTIONS)RESTRICTED ACCESSCONDUITGAS SHUT OFFWATER SHUT OFFSERVICE DROPPOWER LINESPTILBS7ZGASH2OBREAK AND WATER LOGTHIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES. THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS ISCOMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREESNAME0800HRS0900HRS1000HRS1100HRS1200HRS1300HRS1400HRS1500HRS1600HRS JOB HAZARD ANALYSISCrew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site CaptureLadder Access·Ladders must be inspected before each use.·Extension ladders must be set up on a firm and level surface ata 4-to-1 rise to run angle (or 75 degrees) and the top must besecured to the structure. Extension style ladders placed onuneven, loose or slippery surfaces must additionally have thebase firmly anchored or lashed so the base will not slip out.·Extension ladders must be used with walk-through devices orthe ladder must extend 36" above the stepping off point.·A-frame ladders must only be climbed with the ladder spreaderbars locked in the open position; A-frame ladders shall not beclimbed while in the closed position (ex, closed and used whileleaned against a structure).·Additional notes:Mobile Equipment·Only Qualified operators will operate equipment; operators mustmaintain a certification on their person for the equipment beingoperated.·Type(s) of mobile equipment (Type/Make/Model):·Qualified operator(s):Material Handling and Storage·Materials will be staged/stored in a way that does not present ahazard to client, personnel or public. Materials stored on theroof will be physically protect from failing or sliding off.Fall Protection·A site-specific plan for fall prevention and protection is requiredprior to starting work and must remain onsite at all times untilwork is complete; a fall rescue plan must be outlined anddiscussed among the crew prior to work start.·First-person-Up (FPU) must install their anchor and connectbefore any other task, including installing other anchors. TheLast-Person-Down (LPD) must be the only person on a roofuninstalling fall protection.·FPCP (name and title):·FPU and LPD (name and title):Electrical Safety·The Electrical Qualified Person (EQP) is required onsite toperform electrical work.·All electrical work will be performed with equipment in anelectrically safe condition (de-energized) unless approval hasbeen granted prior to work.·Service drops and overhead electrical hazards will be indentifiedand protected from contact, as neccessary.·EQP (name and tile):Public Protection·The safety of the Client and Public must be maintained at alltimes.·The Client and the Public shall be prevented from entering thework zone through the use of barriers and/or signage, asrequired.·Company, Client and Public property shall be protected fromfalling objects.·Pets (including dogs) shall be secured by their owners prior towork start.·The Client should not leave pets, family members, or others incharge or care of Employees, Contractors, or TemporaryWorkers.·Crew leader responsible for communication with the client:·Client and public is excluded from work area by barricades (N/A,Yes, No):Training and Pre-Job Safety Briefing·All employees onsite shall be made aware of the specific hazardsof this project and review this HJA during a pre-job briefing, andtheir signature indicates awareness of site conditions and theplan to eliminate any hazards identified prior to and during theproject.·Crew leader (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):·Crew member (name/title):Airborne Contaminants:·Asbestos-containing (Transite) piping (ACP) - Do not disturb(move, drill, cut fracture, etc.)·Asbestos-containing thermal insulation (ACI) andAsbestos-containing duct wrapping (ACW) - do not disturb, noattic or crawlspace access is allowed if work to be performedcould cause exposure to personnel, client or public.·If yes, list specific tasks and protection in place:Weather and Environment·The site supervisor shall forecast the weather conditions at thejob site, prior to crew arrival, in order to mitigate any hazardsassociated with inclement weather (heat, cold, wind, rain, etc.)·The site supervisor will utilized a portable wind meter(anemometer) to verify actual onsite wind conditions, by checkingat the ground and on any elevated work surface (ex, rooftop)prior to work start, at midday and prior to solar panel staging on aroof.·Elevated work involving the moving or maneuvering of solarpanels shall cease at 25mph (sustained wind) until windsubsides.·Forecasted weather maximum temp (degrees f):Heat Related Illness Prevention·Employees shall have access to potable drinking water that isfresh, pure, and suitably cool. The water shall be located asclose as practicable to the areas where employees are working.Water shall be supplied in sufficient quantity at the beginning ofthe work shift to provide at least one quart per employee perhour for drinking for the entire shift. Employees may begin theshift with smaller quantities of water if they identify the locationand have effective means for replenishment during the shift toallow employees to drink on quart or more per hour. Thefrequent drinking of water shall be encouraged.·Shade shall be present when temperature exceeds 80 degreesFahrenheit. When the outdoor temperature in the work exceeds80 degrees Fahrenheit, employees shall have and maintain oneor more areas with shade at all times.·New employees must be acclimatized. New employees will bemonitored by their Crew Leader (site supervisor) for the first two(2) weeks of employment or longer when necessary.·Employees will be allowed and encouraged to implementscheduled breaks during each shift. Employees must takecool-down breaks in the shade any time they feel the need to doso to protect them from overheating. Supervisors areREQUIRED to allow employees any break period they needduring high heat conditions.·Cool Vests are encouraged for all employees at all times duringperiods of high heat.·Identify the location of the closet Occupational/Industrial Clinicor Hospital in case a crew member becomes ill.What is the specific plan to provide and replenish sufficient water forall employees on site?·If offsite replenish is necessary, where will you go to replenishwater (location/address):·Who will replenish the drinking water (name):Restroom facilities·Employees shall have access to restroom facilities withhand-washing stations. Use of onsite restroom is at the client'sdiscretion (location is annotated below). If client does not givepermission, location of suitable restroom facilities withhand-washing stations offsite will be provided. The onsitesupervisor will identify location and make arrangements toensure all employees have access at any point.·Restroom facilities will be (circle one): Onsite - Offsite·If Offsite, add location name and address:Incident Reporting Procedure·Contact your Site SupervisorName:Phone:·Contact your ManagerName:Phone:·Contact your Site SupervisorName:Phone:With: Your full name, phone number, office location, brief descriptionof what happen and when.NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE(add as many as necessary by using additional sheets)Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:Define the Hazard:Method/steps to prevent incident:PV-10FREEDOM FOREVER INDY 8.00 TEMPLATE CONTRACTOR LICENSE:HOME IMPROVEMENT CONTRACTOR 198080;BUSINESS ELECTRICAL CONTRACTOR LICENSE902-EL-A1; CONSTRUCTION SUPERVISORLICENSE CS-111662; MASTER ELECTRICIAN1136 MRFREEDOM FOREVER LLC135 ROBERT TREAT PAINE DR., TAUTON, MA02780Tel: (800) 385-1075REVISED BYDATENO.SHEET:REVISIONSJOB NO:355652DESIGNED BY:N.W.CLIENT:BARRY GRUBER128 BROOKSIDE CIR, NORTHAMPTON, MA01062AHJ: CITY OF NORTHAMPTON (MA)UTILITY: NG - NATIONAL GRID (MA)PHONE: (203) 883-2779EMAIL: BMGRUBER@GMAIL.COMFINANCE: SUNRUNSYSTEM:SYSTEM SIZE (DC): 19 X 395 = 7.505 kWSYSTEM SIZE (AC): 6.000 kW @ 240VMODULES: 19 X CANADIAN SOLAR:CS3N-395MSOPTIMIZERS: 19 X SOLAREDGE S440INVERTER: SOLAREDGE SE6000H-USRGM[SI1]DATE:7/18/2023---------SAFETY PLANGREG ALBRIGHT SCAN QR CODE TO ACCESS REFERENCE LINKPV INSTALLATION REFERENCESFREEDOM REFERENCESBATTERY INSTALLATION REFERENCESENPHASE IQ8SOLAREDGE HD WAVE TESLA INVERTERINSTALL HOTLINETESLA POWERWALL 2SHIFT/SELF CONSUMPTION SOLAREDGE ENERGY BANKSOLAREDGE LG RESU (BACKUP) TESLA POWERWALL+ (BACKUP)FOR INSTALLATION REFERENCE ONLYV1.1 CS3N-380|385|390|395|400MS 380 W ~ 400 W BLACK FRAME ON BLACK BACKSHEET MONO PERC MODULE Canadian Solar (USA) Inc.is committed to providing high quality solar products, solar system solutions and services to customers around the world. Canadian Solar was recognized as the No. 1 module supplier for quality and performance/price ratio in the IHS Module Customer Insight Survey, and is a leading PV project developer and manufacturer of solar modules, with over 52 GW deployed around the world since 2001. MORE RELIABLE Comprehensive LID / LeTID mitigation technology, up to 50% lower degradation Module power up to 400 W Module efficiency up to 19.7%400 W Better shading tolerance Minimizes micro-crack impacts * For detailed information, please refer to the Installation Manual. MORE POWER Lower LCOE & BOS cost HiKuBlack Heavy snow load up to 5400 Pa, enhanced wind load up to 2400 Pa* 12Years Years products you order or use. Please contact your local Canadian Solar sales representative in which the products will be used. PRODUCT CERTIFICATES* MANAGEMENT SYSTEM CERTIFICATES* *According to the applicable Canadian Solar Limited Warranty Statement. Enhanced Product Warranty on Materials and Workmanship* Linear Power Performance Warranty* 1st year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% IEC 61215 / IEC 61730 / CE FSEC (US Florida) UL 61730 / IEC 61701 / IEC 62716 May 2021 | All rights reserved | Module Product Datasheet v2.7_F30_J2_NACanadian Solar (USA) Inc. PARTNER SECTION ENGINEERING DRAWING (mm)CS3N-400MS / I-V CURVES products due to the on-going innovation and product enhancement. CSI Solar Co., Ltd. reserves the right to make necessary adjustment to the information described herein at any time without further notice. professional skills and please carefully read the safety and installation instructions before using our PV modules. MECHANICAL DATA Data Cell Type Mono-crystalline Cell Arrangement 132 [2 X (11 X 6) ] Dimensions Weight Front Cover 3.2 mm tempered glass Frame Anodized aluminium alloy Cable 4 mm 2 (IEC), 12 AWG (UL) Cable Length (Including Connector) 1650 mm (65.0 in) (-) / 1000 mm (39.4 in) (+)* Connector T4 series or MC4 Per Pallet 30 pieces 720 pieces * For detailed information, please contact your local Canadian Solar sales and technical representatives. TEMPERATURE CHARACTERISTICS Data -0.34 % / °C -0.26 % / °C 0.05 % / °C Nominal Module Operating Temperature 41 ± 3°C V A 12 11 10 7 6 5 4 3 2 1 0 V A 1000 W/m 2 2 600 W/m2 400 W/m2 200 W/m2 5°C 25°C 45°C 65°C 12 11 10 7 6 5 4 3 2 1 0 06 55 05 54 04 53 03 52 02 51 01 5 06 55 05 54 04 53 03 52 02 51 01 5 Rear View Mounting Hole 1000 6-5Grounding Hole Mounting Hole A A B B Frame Cross Section A - A B - B 2535 ELECTRICAL DATA | STC* CS3N 380MS 385MS 390MS 395MS 400MS 380 W 385 W 390 W 395 W 400 W Opt. Operating Voltage (Vmp) 36.4 V 36.6 V 36.8 V 37.0 V 37.2 V Opt. Operating Current (Imp) 10.44 A 10.52 A 10.60 A 10.68 A 10.76 A Open Circuit Voltage (Voc) 43.7 V 43.9 V 44.1 V 44.3 V 44.5 V Short Circuit Current (Isc) 11.26 A 11.32 A 11.38 A 11.44 A 11.50 A 19.2% 19.4% 19.7%18.7% 18.9% Operating Temperature 1000V (IEC/UL) Module Fire Performance TYPE 1 (UL 61730 1500V) or TYPE 2 (UL 61730 1000V) or CLASS C (IEC 61730) 20 A Class A Power Tolerance * Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA | NMOT* CS3N 380MS 385MS 390MS 395MS 400MS 285 W 34.1 V 8.35 A 41.3 V 9.08 A 289 W 34.3 V 8.42 A 41.5 V 9.13 A 293 W 34.5 V 8.48 A 41.7 V 9.18 A 296 W 34.7 V 8.54 A 41.9 V 9.22 A 300 W 34.9 V 8.60 A 42.1 V 9.27 A Opt. Operating Voltage (Vmp) Opt. Operating Current (Imp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) 2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. Product specificationsEaton DG222URBCatalog Number: DG222URBEaton General duty non-fusible safety switch, single-throw, 60 A, NEMA 3R,Rainproof, Painted galvanized steel, Two-pole, Two-wire, 240 VGeneral specificationsEaton general duty non-fusible safetyswitchDG222URB7821131442387.38 in 14.38 in8.69 in 9 lbEaton Selling Policy 25-000, one (1) yearfrom the date of installation of theProduct or eighteen (18) months from thedate of shipment of the Product,whichever occurs first.UL ListedWARNING! Switch is not approved forservice entrance unless a neutral kit isinstalled.Product Name Catalog NumberUPCProduct Length/Depth Product HeightProduct Width Product WeightWarranty CertificationsCatalog NotesEaton Corporation plcEaton House30 Pembroke RoadDublin 4, IrelandEaton.com© 2023 Eaton. All RightsReserved.Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners.Eaton.com/socialmediaProduct specificationsGeneral duty safety switchPainted galvanized steelNon-fusible, single-throwNon-fusible2NEMA 3R240V60ATwo-poleResourcesEaton's Volume 2—Commercial DistributionDouble Up on SafetySwitching Devices Flex CenterEaton Specification Sheet - DG222URBSelling Policy 25-000 - Distribution and Control Products and ServicesProduct CategoryEnclosure materialTypeFuse configurationNumber of wiresEnclosureVoltage ratingAmperage RatingNumber Of PolesCatalogsMultimediaSpecifications and datasheetsWarranty guides 5Ζ&2036/Ζ'($/%/. 52&.,796/,'(&2030DWHULDO$OXPLQXP)LQLVK%ODFN,7(012'(6&5,37,2152&.,796/,'(&203/$*6&5(:7+5($'(3'0%$&.(':$6+(53$57180%(5'(6&5,37,215,&2036/,'($/%/.REV.- CS15Ζ&2036/Ζ'($/%/. /$*6&5(:7+5($'(3'0%$&.(':$6+(5 7+'+HDG0DWHULDO6WDLQOHVV6WHHO)LQLVK0LOOREV.- CS1 *))/$6+Ζ1**/9%/.; *)0*$/%/.:2:$6+(5$66(0%/<,7(012'(6&5,37,21*)0*$/%/.:2:$6+(5$66(0%/<3$57180%(5'(6&5,37,21*))/$6+,1**/9%/.;REV.- CS17+580DWHULDO&RUURVLRQ5HVLVWDQW6WHHO)LQLVK%ODFN