42-027 BP-2023-0943
795 WESTHAMPTON RD COMMONWEALTH OF MASSACHUSETTS
Map:Block:Lot:
42-027-001 CITY OF NORTHAMPTON
Permit: Solar Build
PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
BUILDING PERMIT
Permit# BP-2023-0943 PERMISSION S HEREBY GRANTED TO:
Project# 2023 SOLAR Contractor: License:
TRINITY HEATING AIR INC DBA
Est. Cost: 41000 TRINITY SOLAR CSL108025
Const.Class: Exp.Date: 04/22/202 •
Use Group: Owner: RISER LAIS RAYMOND &ROSEANNE
Lot Size (sq.ft.)
Zoning: WSP Applicant:
Applicant Address Phone: Insurance:
ISSUED ON: 07/19/2023
TO PERFORM THE FOLLOWING WORK:
INSTALL 21 PANEL 8.505 KW ROOF MOUNT SOLAR
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter: Footings:
Rough: Rough: House# Foundation:
Final: Final: Final: Rough Frame:
Gas: Fire Department Driveway Final: Fireplace/Chimney:
Rough: Oil: Insulation:
Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
fir)
• I • yO - cr
V
Fees Paid: $75.00
212 Main Street,Phone(413)587-1240,Fax:(413)587-1272
Office of the Building Commissioner
I RECEIVE
The Commonwealth of Massach e
Board of Building Regulations and d: ds JUL 1 8 20" 'OR
Massachusetts State BuildingCode, 80 l R I IPALITY
'Lr SE
Building Permit Application To Construct,Repair, 'encl ate.,h i;. 1'6;• . I 'evise, Mar 2011
One-or Two-Family Dwelli': NORTHAMPTON MSAPOE i S
This Section For Official Use 0 ly
Building Permitj(ell
Number: �P )3 - 941 Date Applied:
„.-1 7- r9-zoz3
Building Official(Print Name) Signature Date
SECTION 1: SITE INFORMATION
1.1 Property Address: 1.2 Assessors Map &Parcel Numbers
795 Westhampton Road,Northampton,MA 01062
1.1a Is this an accepted street?yes ✓L no Map Number Parcel Number
1.3 Zoning Information: 1.4 Property Dimensions:
Residential-Solar
Zoning District Proposed Use Lot Area(sq ft) Frontage(ft)
1.5 Building Setbacks(ft)
Front Yard Side Yards Rear Yard
Required Provided Required Provided Required Provided
1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System:
Public 0 Private 0 Zone: _ Outside Flood Zone? Municipal 0 On site disposal system 0
Check if yes❑
SECTION 2: PROPERTY OWNERSHIP'
2.1 Owner'of Record:
Raymond Risner Northampton MA 01062
Name(Print) City,State,ZIP
795 Westhampton Road (413)276-6563 fnishtouchllc(aiaol.com
No.and Street Telephone Email Address
SECTION 3: DESCRIPTION OF PROPOSED WORK'(check all that apply)
New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) ❑ Addition 0
Demolition 0 Accessory Bldg. 0 Number of Units Other ESpecify:solar
Brief Description of Proposed Work2:Install 8.505 kW DC solar on roof (21 panels)
Will not exceed building footprint, but will add 6"to roof height.
SECTION 4: ESTIMATED CONSTRUCTION COSTS
Item Estimated Costs: Official Use Only
(Labor and Materials)
1.Building $12,000 1. Building Permit Fee: $ Indicate how fee is determined:
2.Electrical $29,000 ❑Standard City/Town Application Fee
❑Total Project Cost'(Item 6)x multiplier x
3.Plumbing $ 2. Other Fees: $
4.Mechanical (HVAC) $ List:
5.Mechanical (Fire $
Suppression) Total All Fees: //,,,,
Check No. D Check Amount: { 3(1igash Amount:
6.Total Project Cost: $41,000 ❑Paid in Full 0 Outstanding Balance Due:
SECTION 5: CONSTRUCTION SERVICES
5.1 Construction Supervisor License(CSL)
r, • CS-108025 4/22/2024
Phil Smith {`' License Number Expiration Date
Name of CSL Holder
List CSL Type(see below) U
6 Torrey St
No.and Street Type Description
U Unrestricted(Buildings up to 35,000 cu.ft.)
Easthampton,MA 01027 R Restricted 1&2 Family Dwelling
City/To to ZIP M Masonry
RC Roofing Covering
X WS Window and Siding
SF Solid Fuel Burning Appliances
413-203-9088 x 1521 applications.westma@trinity-solar.com _ I Insulation
Telephone Email address D Demolition
5.2 Registered Home Improvement Contractor(HIC) 170355 10/11/2023
Trinity Solar Inc DBA Trinity Solar HIC Registration Number Expiration Date
HIC Company Name or HIC Registrant Name
20 Patterson Brook Road-Unit 10 applications.westma@trinity-solar.com
No.and Street' Email address
West Wareham MA 02576 413-203-9088 x 1521
City/Town, State,ZIP Telephone
SECTION 6:WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide
this affidavit will result in the denial of the Issuance of the building permit.
Signed Affidavit Attached? Yes ® No 0
SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN
OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
I,as Owner of the subject property,hereby authorize Please See Attached
to act on my behalf,in all matters relative to work authorized by this building permit application.
Print Owner's Name(Electronic Signature) Date
SECTION 7b: OWNER'OR AUTHORIZED AGENT DECLARATION
By entering my name belo I hereby attest under the pains and penalties of perjury that all of the information
containe i app • on is true and ate to the best of my knowledge and understanding.
X 07/17/2023
Print Owner' or Authorized Agent's Name(Electronic Signature) Date
NOTES:
1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor
(not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration
program or guaranty fund under M.G.L. c. 142A. Other important information on the HIC Program can be found at
www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps
2. When substantial work is planned,provide the information below:
Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch)
Gross living area(sq.ft.) Habitable room count
Number of fireplaces Number of bedrooms
Number of bathrooms Number of half/baths
Type of heating system Number of decks/porches
Type of cooling system Enclosed Open
3. "Total Project Square Footage"may be substituted for"Total Project Cost"
City of Northam ton
` � Massachusetts ti �,:
4:- r.:
w ‘''7 .4),,
a� 3 . DEPARTMENT OF BUILDING INSPECTIONS * 4
., k"�,jt 212 Main Street • Municipal Building �
—"� Northampton, MA 01060 '1�'
4 go
CONSTRUCTION DEBRIS AFFIDAVIT
(FOR ALL DEMOLITION AND RENOVATION PROJECTS)
In accordance of the provisions of MGL c 40, S54, a condition of Building Permit
Number is that all debris resulting from this work shall be disposed of
in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A.
The debris will be disposed of in:
Location of Facility: Casella- 295 Forest Street, Peabody, MA 01960
The debris will be transported by:
Name of Hauler: Trinity Solar
Signature of Applicant: Date:
7/17/2023
• NJ,Electrical Contractor business permit number34EB01547400
NJ,HIC reg.#13VH01244300
SOLAR For other jurisdictions,please visit:http://www.trinity-solar.com/about-us/locations-and-licenses
HOMEOWNERS AUTHORIZATION FORM
Raymond Blais
(print name)
am the owner of the property located at address:
795 Westhampton RoeNorthampton MA
(print address)
I hereby authorize Trinity Solar Inc. ("Trinity Solar") and its employees, agents, and
subcontractors, including without limitation, , to act as my Agent for the
limited purpose of applying for and obtaining local building and other permits from the Authority Having
Jurisdiction as required for the installation of a Photovoltaic System, Battery System, roofing or other
Trinity Solar offerings located on my property, applying and obtaining permission and approval for
interconnection with the electric utility company, and registration with any state and/or local incentive
progra m(s).
This authorization includes the transfer/re-administering, and/or cancellation of any existing
permits on file for the purpose of updating/applying with an alternate subcontractor.
Without limitation to the generality of the foregoing I specifically authorize Trinity Solar et al.to
populate technical details,fill-in, edit, compile, attach drawings, plans, data sheets and other
documentation to, date, submit, re-submit, revise, amend and modify application, submission and
certification documents ("Approvals Paperwork"), including those for which signature pages are included
herewith for my signature, in furtherance of the related transaction, and I am providing any signatures to
Approvals Paperwork for purposes of the foregoing.Trinity Solar will provide copies of Approvals
Paperwork when submitted. My authorizations memorialized herein shall remain in full force and effect
until revoked. I acknowledge that these authorizations are not required to proceed with the transaction
and are not a condition of the related agreement included herewith but are being given for my own
convenience and benefit in order to expedite the approvals processes.
Electric Utility Company: Nationalgrld
Electric Utility Account No.: 51458-54007
Name on Electric Utility Account: Rosanne Risner
Pck-rer---sc .5‘ ,)
Customer Signature
Raymond Blais
Print Name
May 9, 2023
Date
Corporate Headquarters 1-877-SUN-SAVES
2211 Allenwood Road Ph: 732-780-3779
Wall, New Jersey 07719 Fax: 732-780-6671
www.trinity-solar.com
FOR INFORMATION ABOUT CONTRACTORS AND THE CONTRACTORS' REGISTRATION ACT,
CONTACT THE NEW JERSEY DEPARTMENT OF LAW AND PUBLIC SAFETY,
DIVISION OF CONSUMERS AFFAIRS AT 1-888-656-6225.
•
SOLAR
Northampton, MA June 8, 2023
212 Main St.
Northampton, MA 01060
RE: BLAIS, RAYMOND; RISER, ROSEANNE Trinity Solar No.
795 Westhampton Road 2023-05-873591
Northampton, MA 01062
To the Building Official:
The following information constitutes a summary of the relevant design criteria and recommendations for the support of a new photovoltaic
[PV] system on the existing roof framing components at the above-referenced location.
Criteria is as follows:
1. Existing roof framing:
Conventional roof framing at R1 is 4x6 at 24 o.c.; existing rafter span=6'6"; (horizontal projection)
Conventional roof framing at R2 is 4x6 at 24 o.c.; existing rafter span= 14'0"; (horizontal projection)
Conventional roof framing at R4 is true 2x10 at 16 o.c.; existing rafter span= 13'6"; (horizontal projection)
Conventional roof framing at R14 is 2x8 at 16 o.c.; existing rafter span=8'0"; (horizontal projection)
2. Roof Loading:
• 3.0psf dead load (pounds per square foot- PV panels, mounting rails&hardware)
• 5.7psf-existing roof loads(1.7 psf-4x6 framing, 1.5psf roof sheathing, 2.5 psf shingles)
• 6.9psf-existing roof loads(2.9 psf-2x10 framing, 1.5psf roof sheathing,2.5 psf shingles)
• 6.3psf-existing roof loads(2.3 psf-2x8 framing, 1.5psf roof sheathing, 2.5 psf shingles)
• Ground Snow Load-40psf-per AHJ (Authority Having Jurisdiction)
• Wind criteria-Exposure Category B, 117 mph wind
3. Existing Roof modification-none required; existing roof framing is acceptable for PV installation.
This installation design is in general conformance with the manufacturers'specifications and complies with all applicable laws, codes, and
ordinances—specifically the International Building Code (2015 edition)and the International Residential Code(2015 edition), including all
Massachusetts regulations and amendments.
The spacing and fastening of the mounting brackets is a maximum of 48"o.c. between mounting brackets(staggered)and is secured using
5/16"diameter corrosive-resistant steel lag bolts.A minimum of 21/2"of penetration (embedment)per lag bolt is required, which will resist all
stated loads above—including wind shear. Per NDS Section 12.1.4, clearance holes-equal to the diameter of the shank-need to be
bored into a primary framing member for the full-length of the threaded portion of the bolt to avoid splitting of the framing member.
Regards,
lhor Bojcun, PE
Structural Engineer-Trinity Solar
1 or
il
F • , as,
♦ _per t...
r ,
MA License No.56687