42-027 BP-2023-0943 795 WESTHAMPTON RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 42-027-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2023-0943 PERMISSION S HEREBY GRANTED TO: Project# 2023 SOLAR Contractor: License: TRINITY HEATING AIR INC DBA Est. Cost: 41000 TRINITY SOLAR CSL108025 Const.Class: Exp.Date: 04/22/202 • Use Group: Owner: RISER LAIS RAYMOND &ROSEANNE Lot Size (sq.ft.) Zoning: WSP Applicant: Applicant Address Phone: Insurance: ISSUED ON: 07/19/2023 TO PERFORM THE FOLLOWING WORK: INSTALL 21 PANEL 8.505 KW ROOF MOUNT SOLAR POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: fir) • I • yO - cr V Fees Paid: $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner I RECEIVE The Commonwealth of Massach e Board of Building Regulations and d: ds JUL 1 8 20" 'OR Massachusetts State BuildingCode, 80 l R I IPALITY 'Lr SE Building Permit Application To Construct,Repair, 'encl ate.,h i;. 1'6;• . I 'evise, Mar 2011 One-or Two-Family Dwelli': NORTHAMPTON MSAPOE i S This Section For Official Use 0 ly Building Permitj(ell Number: �P )3 - 941 Date Applied: „.-1 7- r9-zoz3 Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map &Parcel Numbers 795 Westhampton Road,Northampton,MA 01062 1.1a Is this an accepted street?yes ✓L no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Residential-Solar Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: _ Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Raymond Risner Northampton MA 01062 Name(Print) City,State,ZIP 795 Westhampton Road (413)276-6563 fnishtouchllc(aiaol.com No.and Street Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) ❑ Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units Other ESpecify:solar Brief Description of Proposed Work2:Install 8.505 kW DC solar on roof (21 panels) Will not exceed building footprint, but will add 6"to roof height. SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $12,000 1. Building Permit Fee: $ Indicate how fee is determined: 2.Electrical $29,000 ❑Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees: //,,,, Check No. D Check Amount: { 3(1igash Amount: 6.Total Project Cost: $41,000 ❑Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) r, • CS-108025 4/22/2024 Phil Smith {`' License Number Expiration Date Name of CSL Holder List CSL Type(see below) U 6 Torrey St No.and Street Type Description U Unrestricted(Buildings up to 35,000 cu.ft.) Easthampton,MA 01027 R Restricted 1&2 Family Dwelling City/To to ZIP M Masonry RC Roofing Covering X WS Window and Siding SF Solid Fuel Burning Appliances 413-203-9088 x 1521 applications.westma@trinity-solar.com _ I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 170355 10/11/2023 Trinity Solar Inc DBA Trinity Solar HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 20 Patterson Brook Road-Unit 10 applications.westma@trinity-solar.com No.and Street' Email address West Wareham MA 02576 413-203-9088 x 1521 City/Town, State,ZIP Telephone SECTION 6:WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ® No 0 SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Please See Attached to act on my behalf,in all matters relative to work authorized by this building permit application. Print Owner's Name(Electronic Signature) Date SECTION 7b: OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name belo I hereby attest under the pains and penalties of perjury that all of the information containe i app • on is true and ate to the best of my knowledge and understanding. X 07/17/2023 Print Owner' or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L. c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" City of Northam ton ` � Massachusetts ti �,: 4:- r.: w ‘''7 .4),, a� 3 . DEPARTMENT OF BUILDING INSPECTIONS * 4 ., k"�,jt 212 Main Street • Municipal Building � —"� Northampton, MA 01060 '1�' 4 go CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40, S54, a condition of Building Permit Number is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A. The debris will be disposed of in: Location of Facility: Casella- 295 Forest Street, Peabody, MA 01960 The debris will be transported by: Name of Hauler: Trinity Solar Signature of Applicant: Date: 7/17/2023 • NJ,Electrical Contractor business permit number34EB01547400 NJ,HIC reg.#13VH01244300 SOLAR For other jurisdictions,please visit:http://www.trinity-solar.com/about-us/locations-and-licenses HOMEOWNERS AUTHORIZATION FORM Raymond Blais (print name) am the owner of the property located at address: 795 Westhampton RoeNorthampton MA (print address) I hereby authorize Trinity Solar Inc. ("Trinity Solar") and its employees, agents, and subcontractors, including without limitation, , to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System, Battery System, roofing or other Trinity Solar offerings located on my property, applying and obtaining permission and approval for interconnection with the electric utility company, and registration with any state and/or local incentive progra m(s). This authorization includes the transfer/re-administering, and/or cancellation of any existing permits on file for the purpose of updating/applying with an alternate subcontractor. Without limitation to the generality of the foregoing I specifically authorize Trinity Solar et al.to populate technical details,fill-in, edit, compile, attach drawings, plans, data sheets and other documentation to, date, submit, re-submit, revise, amend and modify application, submission and certification documents ("Approvals Paperwork"), including those for which signature pages are included herewith for my signature, in furtherance of the related transaction, and I am providing any signatures to Approvals Paperwork for purposes of the foregoing.Trinity Solar will provide copies of Approvals Paperwork when submitted. My authorizations memorialized herein shall remain in full force and effect until revoked. I acknowledge that these authorizations are not required to proceed with the transaction and are not a condition of the related agreement included herewith but are being given for my own convenience and benefit in order to expedite the approvals processes. Electric Utility Company: Nationalgrld Electric Utility Account No.: 51458-54007 Name on Electric Utility Account: Rosanne Risner Pck-rer---sc .5‘ ,) Customer Signature Raymond Blais Print Name May 9, 2023 Date Corporate Headquarters 1-877-SUN-SAVES 2211 Allenwood Road Ph: 732-780-3779 Wall, New Jersey 07719 Fax: 732-780-6671 www.trinity-solar.com FOR INFORMATION ABOUT CONTRACTORS AND THE CONTRACTORS' REGISTRATION ACT, CONTACT THE NEW JERSEY DEPARTMENT OF LAW AND PUBLIC SAFETY, DIVISION OF CONSUMERS AFFAIRS AT 1-888-656-6225. • SOLAR Northampton, MA June 8, 2023 212 Main St. Northampton, MA 01060 RE: BLAIS, RAYMOND; RISER, ROSEANNE Trinity Solar No. 795 Westhampton Road 2023-05-873591 Northampton, MA 01062 To the Building Official: The following information constitutes a summary of the relevant design criteria and recommendations for the support of a new photovoltaic [PV] system on the existing roof framing components at the above-referenced location. Criteria is as follows: 1. Existing roof framing: Conventional roof framing at R1 is 4x6 at 24 o.c.; existing rafter span=6'6"; (horizontal projection) Conventional roof framing at R2 is 4x6 at 24 o.c.; existing rafter span= 14'0"; (horizontal projection) Conventional roof framing at R4 is true 2x10 at 16 o.c.; existing rafter span= 13'6"; (horizontal projection) Conventional roof framing at R14 is 2x8 at 16 o.c.; existing rafter span=8'0"; (horizontal projection) 2. Roof Loading: • 3.0psf dead load (pounds per square foot- PV panels, mounting rails&hardware) • 5.7psf-existing roof loads(1.7 psf-4x6 framing, 1.5psf roof sheathing, 2.5 psf shingles) • 6.9psf-existing roof loads(2.9 psf-2x10 framing, 1.5psf roof sheathing,2.5 psf shingles) • 6.3psf-existing roof loads(2.3 psf-2x8 framing, 1.5psf roof sheathing, 2.5 psf shingles) • Ground Snow Load-40psf-per AHJ (Authority Having Jurisdiction) • Wind criteria-Exposure Category B, 117 mph wind 3. Existing Roof modification-none required; existing roof framing is acceptable for PV installation. This installation design is in general conformance with the manufacturers'specifications and complies with all applicable laws, codes, and ordinances—specifically the International Building Code (2015 edition)and the International Residential Code(2015 edition), including all Massachusetts regulations and amendments. The spacing and fastening of the mounting brackets is a maximum of 48"o.c. between mounting brackets(staggered)and is secured using 5/16"diameter corrosive-resistant steel lag bolts.A minimum of 21/2"of penetration (embedment)per lag bolt is required, which will resist all stated loads above—including wind shear. Per NDS Section 12.1.4, clearance holes-equal to the diameter of the shank-need to be bored into a primary framing member for the full-length of the threaded portion of the bolt to avoid splitting of the framing member. Regards, lhor Bojcun, PE Structural Engineer-Trinity Solar 1 or il F • , as, ♦ _per t... r , MA License No.56687 Trinity Solar 14 Open Square Way,Suite 410 I Holyoke, MA i(413)203-9088