Loading...
Revision101911 Garage Plans 32x32Garage10'2'-8"10'2'-8"27'6'-412"17'-8"Fire Ratedcorridor to main houseDoor12712712730 minutes fire rated wall and ceiling 5/8" Gwb assemblies where indicated. FR Note:30 minutes fire rated wall extend to corridor roof underside. Gable truss type fink at @ 24" max 4" concrete slab on vapor barrier over compacted gravel base on compacted fill.8"8'-2"8'-6"8'-1012"1'29'2 Bay GarageOpenOpen29'8'-412"8'-1"vinyl siding to match existing corridor roof behindintersecting with garage30 minutes fire rated wall extend to corridor roof underside. fire rated door7'-1012"deck behind17'-212"29'3'-2"10'-0"2'-8"10'-0"3'-2"29'17'-212"29'17'-212"South ElevationNorth ElevationWest ElevationEast ElevationTransversal Section28'Floor Plan3A1SA6SA6STA6SA6NA6EA6WA66'-412"4'-8"6'-712"3'4'-912"4'-8"9'-512"4'-8"GGTruss Bracing Notes:Permanent Truss Bracing to be accomplished by means of :* Lateral continuos bracing across same web member of all trusses. minimum overlap 2 feet.. * Diagonal bracing beetwen web members accross 3 trusses. spaced not more than 20 feet. * Top Chord Plane braced by structural sheating plywood oriented strand board. field built truss between last two gable trusses at both ends of the structure..Gable truss bracingsee reference notes * End Gable Trusses to be additionally reinforced by diagonal bracing to roof Wall / Truss connections by steel supports attached to continuos.* Bottom Chord Plane to be braced by Gwb Ceiling and additional flat horizontal diafragm blocking. bearing walls top plates.2'-8"10'2'-8"10'2'-8"Wall Bracing Panels to conform with IRC R602.10. as described below:* Continuos Wood Structural Panel Sheating.* 32 " minimun width for each wall bracing panel unit. (above 24" min required per proportional height).* 32' max distance between wall brace lines ( below 35' max distance allowed). Wall Bracing Notes:Applicable to both attached and unattached garage buildings.* 96 " minimum wall braced paneling per braced wall line (above 20% required).29'(32' for Unattached Garage Bulding, See F/A6 )NOTE : Same layout for Unattached Building 32'-0" x 32'-0" Attached Building 29'-0" x 29'-0"Applicable to both attached and unattached garage buildings.Overhead Door size to remain in both garagesto remain both garagesUnattached GarageFloor Plan SectionFA6For Unattached Building 32'-0" x 32'-0", #2 wall bracing line 32'3'3'-6"3'-6"3'8'3'8'3'-2"2'-8"2'-8"project:owner: ' ''DQLHO*yPH]Revision : Oct. 19, 2011Wing RenovationDean PowersA6Powers House Renovation 1140 Florence Road, Florence MA 01062GARAGE PLANSScale: 1'-0" = 1/8"Builder: Roy OmastaSame layout for both attached 29' x 29' and unattached 32' x 32' Garage Units.