Loading...
updated design 4/3/23INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM 824 RYAN ROAD NORTHAMPTON, MA 01062 42.310716,-72.704027 RYAN ROAD R3 SYSTEM SIZE DECREASE 3/30/2023 R2 SYSTEM SIZE DECREASE 3/17/2023 R1 INVERTER CHANGE 2/21/2023 P1 ISSUED TO TOWNSHIP FOR PERMIT 10/5/2022 NO.DESCRIPTION DATE APOLINARIO, JILL (ADD- ON) TRINITY ACCT #: 2022-08-745201 824 RYAN ROAD NORTHAMPTON, MA 01062 42.310716,-72.704027 PROPOSED PV SOLAR SYSTEM DRAWING DATE:10/5/2022 DRAWN BY:KTD REVISED BY:DMR DC SYSTEM SIZE:7.6kW AC SYSTEM SIZE:6kW MODULE COUNT:19 MODULES USED:HANWHA 400 MODULE SPEC #:Q.PEAK DUO BLK ML-G10.a+ 400 UTILITY COMPANY:NAT'L GRID UTILITY ACCT #:01668-37029 UTILITY METER #:98917340 DEAL TYPE:SUNNOVA R3 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com ROOF 1 MODULES: 0 PITCH: 25° ORIENTATION: 80° ROOF 2 MODULES: 16 PITCH: 25 ORIENTATION: 260 ROOF 3 MODULES: 0 PITCH: 28° ORIENTATION: 40° ROOF 4 MODULES: 0 PITCH: 30° ORIENTATION: 350° ROOF 5 MODULES: 0 PITCH: 28° ORIENTATION: 220° ROOF 6 MODULES: 0 PITCH: 28° ORIENTATION: 310° ROOF 7 MODULES: 3 PITCH: 25 ORIENTATION: 260 ROOF 8 MODULES: 0 PITCH: 25° ORIENTATION: 80° ROOF 9 MODULES: 0 PITCH: 30° ORIENTATION: 170° ROOF 10 MODULES: 0 PITCH: 24° ORIENTATION: 80° ROOF 11 MODULES: 0 PITCH: 24° ORIENTATION: 260° ROOF 12 MODULES: 0 PITCH: 28° ORIENTATION: 130° ROOF 13 MODULES: 0 PITCH: 28° ORIENTATION: 261° ROOF 14 MODULES: 0 PITCH: 23° ORIENTATION: 170° ROOF 15 MODULES: 0 PITCH: 23° ORIENTATION: 350° ROOF 16 MODULES: 0 PITCH: 20° ORIENTATION: 261° ROOF 17 MODULES: 0 PITCH: 20° ORIENTATION: 81° ROOF 18 MODULES: 0 PITCH: 6° ORIENTATION: 81° ROOF 19 MODULES: 0 PITCH: 28° ORIENTATION: 78° DC ACD DC AC D UD epM NS27090 1 3 5 2254531542.310716,-72.704027 19 HANWHA 400 (Q.PEAK DUO BLK ML-G10.a+ 400) 1 SE6000H-US0SHBNC4 IN BASEMENT OUTSIDE. OUTSIDE (UTILITY ACCESSIBLE)OUTSIDE. R3 SYSTEM SIZE DECREASE 3/30/2023 R2 SYSTEM SIZE DECREASE 3/17/2023 R1 INVERTER CHANGE 2/21/2023 P1 ISSUED TO TOWNSHIP FOR PERMIT 10/5/2022 NO.DESCRIPTION DATE APOLINARIO, JILL (ADD- ON) TRINITY ACCT #: 2022-08-745201 824 RYAN ROAD NORTHAMPTON, MA 01062 42.310716,-72.704027 PROPOSED PV SOLAR SYSTEM DRAWING DATE:10/5/2022 DRAWN BY:KTD REVISED BY:DMR DC SYSTEM SIZE:7.6kW AC SYSTEM SIZE:6kW MODULE COUNT:19 MODULES USED:HANWHA 400 MODULE SPEC #:Q.PEAK DUO BLK ML-G10.a+ 400 UTILITY COMPANY:NAT'L GRID UTILITY ACCT #:01668-37029 UTILITY METER #:98917340 DEAL TYPE:SUNNOVA R3 NOTES: 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. M UD SP P DC AC ep D DC 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com SD TS NOTE 2021 IRC R324.6.2 PLAN VIEW TOTAL ROOF AREA: 3625.1 FT² PHOTOVOLTAIC ARRAY TOTAL AREA: 676.1 FT² ARRAY PERCENTAGE OF PLAN VIEW TOTAL ROOF AREA: 18.6% CALCULATIONS FOR CURRENT CARRYING CONDUCTORS REQUIRED CONDUCTOR AMPACITY PER STRING [NEC 690.8(B)(1)]: (15.00*1.25)1 = 18.75A AWG #10, DERATED AMPACITY AMBIENT TEMP: 33°C, TEMP DERATING FACTOR: .96 RACEWAY DERATING = 4 CCC: 0.80 (40*.96)0.80 = 30.72A 30.72A >_ 18.75A, THEREFORE WIRE SIZE IS VALID TOTAL AC REQUIRED CONDUCTOR AMPACITY 25.00A*1.25 = 31.25A AWG #8, DERATED AMPACITY AMBIENT TEMP: 30°C, TEMP DERATING: 1.0 RACEWAY DERATING <_ 3 CCC: N/A 55A*1.0 = 55A 55A >_ 31.25A, THEREFORE AC WIRE SIZE IS VALID CALCULATION FOR PV OVERCURRENT PROTECTION TOTAL INVERTER CURRENT: 25.00A 25.00A*1.25 = 31.25A --> 40A OVERCURRENT PROTECTION IS VALID ARRAY CIRCUIT WIRING NOTES 1.) LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH NEC 2020 2.) LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP = -16°C 3.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP = 33°C 4.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS (ALL OF UNITED STATES) 5.) PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH NEC 690.12(A) THROUGH (D) 6.) PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41 (A)(4) 7.) UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH: POSITIVE CONDUCTORS = RED NEGATIVE CONDUCTORS = BLACK NEC 210.5(C)(2) 8.) ARRAY AND SUB ARRAY CONDUCTORS SHALL BE #10 PV WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT SUNLIGHT. SUB ARRAY CONDUIT LONGER THAN 24” SHALL CONTAIN ≤ 20 CURRENT CARYING CONDUCTORS AND WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN ≤ 9 CURRENT CARRYING CONDUCTORS. 9.) ALL WIRE LENGTHS SHALL BE LESS THAN 100' UNLESS OTHERWISE NOTED 10.) FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON ROOFTOP AND SHALL BE LIMITED TO 12” IF USED OUTDOORS 11.)OVERCURRENT PROTECTION FOR CONDUCTORS CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE LOCATED WITHIN 10' OF THE POINT OF CONNECTION NEC 690.9(A)(3)(2) 12.) WHERE TWO SOURCES FEED A BUSSBAR, ONE A UTILITY AND THE OTHER AN INVERTER, PV BACKFEED BREAKER(S) SHALL BE LOCATED OPPOSITE FROM UTILITY NEC 705.12(B)(3)(2) 13.) ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY GENERATION CIRCUITS AND NO UNUSED POSITIONS OR LOADS 14.) ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE A NEMA 3R RATING LOCKABLE 60A DISCONNECT FUSED W/ 40A FUSES SQUARE D PN: D222NRB ISOLATED NEUTRAL 240V 1Ø EG NOTE: INTERNAL REVENUE GRADE MONITORING CONTAINED WITHIN SOLAR EDGE INVERTER SOLAR EDGE PN. RWND-3D-240-MB INVERTER #1 - SE6000H-US0SHBNC4 DC AC Imp 16.5 Pout 6000 Vmp 380 Imax 25 Voc 480 OCPDmin 31.25 Isc 30 Vnom 240 PV MODULE SPECIFICATIONS HANWHA 400 (Q.PEAK DUO BLK ML-G10.a+ 400) Imp 10.77 Vmp 37.13 Voc 45.3 Isc 11.14 A #6 THWN-2 GEC TO EXISTING GROUND ROD B 3/4'' CONDUIT W/ 2-#8 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND C 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND D 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND E 3/4'' CONDUIT W/ 2-#8 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND F #10 PV WIRE (FREE AIR) W/ #6 BARE COPPER BOND TO ARRAY G 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#6 THWN-2, 1-#8 THWN-2 GROUND NOTE: CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS INVERTER #1 PV+L1 L2 N PV-C SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS 19 - 400W MODULES W/ 1 SOLAR EDGE S440 PER MODULE 15 ADC MAX PER STRING 1 STRING OF 10 MODULES IN SERIES - 380 Vmax 1 STRING OF 9 MODULES IN SERIES - 380 Vmax *2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 8"x8" JUNCTION BOXf SOLAR MODULES MOUNTED TO ROOF ON 4 ARRAYS 19 - 340W MODULES W/ 1 SOLAR EDGE P340 PER MODULE 15 ADC MAX PER STRING 1 STRING OF 11 MODULES IN SERIES - 380 Vmax 1 STRING OF 8 MODULES IN SERIES - 380 Vmax *2 STRINGS TERMINATED IN PARALLEL INSIDE EXISTING INVERTER EXISTING 5K INVERTER PV+L1 L2 N PV-EXISTING 6.46kW PV SOLAR SYSTEM ***NOTE: NEW USAGE REPORTS WARRANT AN INCREASE IN PV BACK FEED. SYSTEMS SHALL REMAIN SEPARATE TO SIMPLIFY MONETARY / REBATE FORMS NEUTRALMEXISTING 120/240V UTILITY METER 2p200AMAIN240V 1Ø 200A MAIN BREAKER 200A BUSBAR EXISTING MAIN BREAKER LOAD CENTER INSULATED LINE TAPS INSTALLED ON MAIN FEEDERS NEC 705.12(A) SQUARE D DU222RB 60A UNFUSED DISCONNECT ISOLATED NEUTRAL 240V 1Ø LOCKABLE 60A DISCONNECT FUSED W/ 30A FUSES SQUARE D PN: D222NRB ISOLATED NEUTRAL 240V 1Ø SMART METER PRODUCTION METER M ISOLATED NEUTRAL LINE SIDE LOAD SIDE SQUARE D DU222RB 60A UNFUSED DISCONNECT ISOLATED NEUTRAL 240V 1Ø R3 SYSTEM SIZE DECREASE 3/30/2023 R2 SYSTEM SIZE DECREASE 3/17/2023 R1 INVERTER CHANGE 2/21/2023 P1 ISSUED TO TOWNSHIP FOR PERMIT 10/5/2022 NO.DESCRIPTION DATE APOLINARIO, JILL (ADD- ON) TRINITY ACCT #: 2022-08-745201 824 RYAN ROAD NORTHAMPTON, MA 01062 42.310716,-72.704027 PROPOSED PV SOLAR SYSTEM DRAWING DATE:10/5/2022 DRAWN BY:KTD REVISED BY:DMR DC SYSTEM SIZE:7.6kW AC SYSTEM SIZE:6kW MODULE COUNT:19 MODULES USED:HANWHA 400 MODULE SPEC #:Q.PEAK DUO BLK ML-G10.a+ 400 UTILITY COMPANY:NAT'L GRID UTILITY ACCT #:01668-37029 UTILITY METER #:98917340 DEAL TYPE:SUNNOVA R3 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com