Dawn Nims 10-26-22 CAD (1)SCOPE OF WORK TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE LOCATED AT 8 CHARLES ST, NORTHAMPTON, MA 01060, USA (LATITUDE & LONGITUDE : 42.307330,-72.641472). THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. EQUIPMENT SUMMARY 25 Q CELLS Q.PEAK DUO BLK-G10+ 365 MODULES 25 ENPHASE IQ8PLUS -72-2-US (240V) MICROINVERTERS GENERAL NOTES THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE MODIFICATIONS IN CONSTRUCTION DETAILS. • ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR INSTALLATION OF ANY EQUIPMENT AT SITE. • CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. • CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL COMPENSATION. • DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST. • THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND COMPLETION OF THE WORK WITH APPROVED MATERIALS. • NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE ARCHITECT. • CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDING PERMIT IS PROPERLY DISPLAYED. • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. • IT 1S ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. • ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO BE PAINTED BY GENERAL CONTRACTOR. • THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. • THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. • CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK.• ELECTRICAL NOTES ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.• ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. • WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. • WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. • WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. • ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.• MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. • MODULE SUPPORT RAIL SHALL BE BONDED TO THE MODULE• GOVERNING CODES 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL RESIDENTIAL CODE 2020 NATIONAL ELECTRICAL CODE AHJ NAME : NORTHAMPTON CITY AHJ ADDRESS : 210 MAIN STREET NORTHAMPTON, MA 01060 AHJ CONTACT NO. : 4135871240 WIRING AND CONDUIT NOTES ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PURPOSE AND APPROVAL FOR THE SITE APPLICATIONS • ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PV WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED • ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE DERATED ACCORDING TO AS PER LATEST NEC CODE. • EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES • PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 1000V AS PER APPLICABLE NEC • 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS • ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION• VOLTAGE DROP LIMITED TO 2%• AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY • VOLTAGE DROP LIMITED TO 2%• AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE AOR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY • SYSTEM RATING 9.125 kWDC 7.250 kWAC SHEET INDEX PV1 COVER PAGE PV2 SITE PLAN PV3 ROOF PLAN PV4 STRUCTURAL DETAILS PV5 ELECTRICAL LINE & CALCS. PV6-PV7 SIGNAGE PV8-PV10 EQUIPMENT SPECIFICATIONS PV11-PV12 SPAN TABLE PV13-PV17 EQUIPMENT SPECIFICATIONS PROJECT SITE HOUSE PHOTO SCALE: NTS PROJECT SITE VICINITY MAP SCALE: NTS SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME COVER PAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-1 10/26/2022 SITE NOTES A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS.• THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.• THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS.• PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110.26]• LEGEND JB (N) JUNCTION BOX UM (E) UTILITY METER MSP (E) MAIN SERVICE PANEL IQ (N) ENPHASE IQ COMBINER AC (N) FUSED AC DISCONNECT VENT, ATTIC FAN (ROOF OBSTRUCTION) ROOF ATTACHMENT -------CONDUIT ENPHASE IQ8PLUS -72-2-US (240V) MICROINVERTER Q CELLS Q.PEAK DUO BLK-G10+ 365 MODULES NXT HORIZON RAIL - 168" MILL TRENCH SCALE: 1/32"= 1'-0" SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME SITE PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-2 10/26/2022 ROOF DESCRIPTION ROOF ROOF TILT AZIMUTH RAFTER SIZE RAFTER SPACING ROOF MATERIAL #1 27°235°2" x 6"16" o.c.COMP SHINGLE #2 27°55°2" x 6"16" o.c.COMP SHINGLE #3 27°145°2" x 6"16" o.c.COMP SHINGLE ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) #1 12 231.76 #2 9 173.82 #3 4 77.26 (TOTAL ARRAY AREA/TOTAL ROOF AREA) X 100% = (482.83/1613.24) X 100% = 29.93% LEGEND JB (N) JUNCTION BOX UM (E) UTILITY METER MSP (E) MAIN SERVICE PANEL IQ (N) ENPHASE IQ COMBINER AC (N) FUSED AC DISCONNECT VENT, ATTIC FAN (ROOF OBSTRUCTION) ROOF ATTACHMENT -------CONDUIT ENPHASE IQ8PLUS -72-2-US (240V) MICROINVERTER Q CELLS Q.PEAK DUO BLK-G10+ 365 MODULES NXT HORIZON RAIL - 168" MILL TRENCH SCALE: 1/8"= 1'-0" SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME ROOF PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-3 10/26/2022 SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME STRUCTURAL DETAILS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-4 10/26/2022 ID TYPICAL INITIAL CONDUCTOR LOCATION FINAL CONDUCTOR LOCATION CONDUCTOR CONDUIT # OF PARALLEL CIRCUITS CURRENT-CARRYING CONDUCTORS IN CIRCUIT CONDUIT FILL PERCENT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT BASE AMP. DERATED AMP. TERM. TEMP. RATING LENGTH VOTAGE DROP 1 2 ARRAY JUNCTION BOX 12 AWG Q CABLE COPPER - 1 2 N/A N/A 10 AWG BARE COPPER 0.76 (54°C)N/A 15.73A 19.66A N/A N/A 75°C 54FT 0.76% 2 2 JUNCTION BOX IQ COMBINER BOX 10 AWG THWN 2 COPPER MIN 0.75" DIA EMT 1 2 14.26%20A 8 AWG THWN-2 COPPER 0.96 (32°C)1 15.73A 19.66A 40A 38.40A 75°C 42FT 0.71% 3 1 IQ COMBINER BOX FUSED AC DISCONNECT 8 AWG THWN 2 COPPER MIN 0.75" DIA EMT 1 3 27.02%40A 8 AWG THWN-2 COPPER 0.96 (32°C)1 30.25A 37.81A 55A 52.80A 75°C 5FT 0.10% 4 1 FUSED AC DISCONNECT MSP 6 AWG THWN 2 COPPER MIN 0.75" DIA EMT 1 2 25.14%N/A 8 AWG THWN-2 COPPER 0.96 (32°C)1 30.25A 37.81A 75A 72.00A 75°C 5FT 0.06% SERVICE INFO UTILITY PROVIDER:NATIONAL GRID AHJ NAME:NORTHAMPTON CITY MAIN SERVICE VOLTAGE:240V MAIN PANEL BRAND:GE MAIN SERVICE PANEL:200 A MAIN BREAKER RATING:200 A MAIN SERVICE LOCATION:SOUTH SERVICE FEED SOURCE:OVERHEAD SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME ELECTRICAL LINE & CALCS. SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-5 10/26/2022 1 WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: POINT OF INTERCONNECTION, MAIN SERVICE DISCONNECT, AC DISCONNECT, AC COMBINER, INVERTER PER CODE: NEC 690.13(B) 2 CAUTION : SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION: POINT OF INTERCONNECTION & INVERTER PER CODE: NEC 690.15 & 690.13(B) 3 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY LABEL LOCATION: MAIN SERVICE DISCONNECT IF MSD IS OUTSIDE PLACE IT THERE / IF MSD IS INSIDE PLACE ON THE AC DISCONNECT PER CODE: 2020 NEC 690.56(C) 4 PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.56(C)(2) ADHESIVE FASTENED SIGNS THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNING AND MARKINGS SHOULD COMPLY WITH ANSI 2535.4 [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] • 5 PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT 30.25 AMPS NOMINAL OPERATING AC VOLTAGE 240 VOLTS LABEL LOCATION: INTERACTIVE SYSTEM POINT OF INTERCONNECTION PER CODE: NFPA 70, NEC 690.54 6 CAUTION CONTAINS MULTIPLE POWER SOURCES LABEL LOCATION: PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES PER CODE: NEC 705.12(C) and 690.59 7 WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: CONDUIT PER CODE: NEC 690.31(D)(2) 8 CAUTION : SOLAR CIRCUIT LABEL LOCATION: MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 1O FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES PER CODE: IFC 606.11.1.4 9 WARNING - Electric Shock Hazard No user serviceable parts inside Contact authorized service provider for assistance LABEL LOCATION: INVERTER & JUNCTION BOXES (ROOF) PER CODE: NEC 690.13 (G)(3) & 690.13 (G)(4) SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME SIGNAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-6 LABEL LOCATION: EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED (PER CODE: NEC 705.10) SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME SIGNAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-7 SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-8 SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-9 SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-10 SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME SPAN TABLE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-11 SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME SPAN TABLE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-12 SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-13 SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-14 SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-15 SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-16 SKYLINE SOLAR LLC HIC : 13VH0613060 ELEC : 34EB00932200 SYSTEM INFO (25) Q CELLS Q.PEAK DUO BLK-G10+ 365 (25) ENPHASE IQ8PLUS -72-2-US (240V) DC SYSTEM SIZE: 9.125 kWDC AC SYSTEM SIZE: 7.250 kWAC METER: 05410585 JOB NO. : 204607 UTILITY ACC NO. : 5018593028 REVISIONS DESCRIPTION DATE REV PROJECT NAME & ADDRESS DAWN NIMSRESIDENCE8 CHARLES ST, NORTHAMPTON, MA 01060, USAEMAIL ID: DAWNNIMS@GMAIL.COMPHONE NO. (802) 451-6942DATE: 10/26/2022 SHEET NAME EQUIPMENT SPECIFICATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-17