Bond, Howard - Ver. 1.03 pt TD SSGO VERNING CODESPARCELMAP PROJECT LOCATION
SHEET INDEX
ENGINEERED BY:
CONTRACTOR:
CONTRACTOR LIC #:
PHONE:
CONTACT NAME:
PHONE:
EMAIL:
DESIGN BY:
PHONE:
HOME OWNER PROJECT LOCATION:
PROJECT DRAFTER:
LICENSE #:
PHONE:
ELECTRICAL UTILITY:
AUTHORITY HAVING
JURISDICTION:
BUILDING:
CONTACT NAME:PHONE:
LICENSE TYPE:
PHONE:
EMAIL:
EMAIL:
PHONE:
SHEET SHEET TITLE
EMAIL:Advanced Solar Solutions
2372 Morse Ave #912
Irvine, CA 92614
PHONE:559-321-7000EMAIL:info@advpermits.com
PROJECT APN:
GENERAL PROJECT & JURISDICTIONAL NOTES
1. UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSED
WRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR
SOLUTIONS IS A VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT
TO CIVIL DAMAGES AND PROSECUTION.
APPLIC ABLE BUILDING CODES:
INTERNATIONAL BUILDING CODE
INTERNATIONAL RESIDENTIAL CODE
INTERNATIONAL FIRE CODE
NATIONAL ELECTRIC CODE
DESIGN CRITERIA
BUILDING OCCUPANCY:
RISK CATEGORY:
EXPOSURE CATEGORY:
SNOW LOAD:
SNOW EXPOSURE:
CONSTRUCTION TYPE:
SCOPE OF WORK
NUMBER
PROPOSED SOLAR EQUIPMENT SITE / PROJECT DETAILS
QTY. EQUIPMENT DESCRIPTION/MFG/MODEL
MODULES
INVERTER(S)
MOUNTING
STANCHIONS
RSD DEVICE
BATTERIES
SYSTEM SIZE DC
SYSTEM SIZE AC
QTY. STRING/CKT.
ELECT. SERVICE
PROJECT TEAM LIST
COPYRIGHT NOTICE
1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH ALL
OSHA REGULATIONS.
2. PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLE
ALL ELECTRICAL ENCLOSURE DEAD FRONTS, COVERS, DOORS, ETC. SHALE BE
OPEN AND ACCESSIBLE FOR INSPECTIONS. WHEN TRENCH AND ROOF INSPECTIONS
ARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOR INSPECTOR.
INSPECTION REQUIREMENTS
1. WHEN APPLICABLE A SMOKE DETECTOR, APPROVED AND LISTED BY THE
STATE FIRE MARSHAL OR ANSI/UL 217 CERTIFIED TO NATIONAL FIRE ALARM
AND SIGNALING CODE, NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED
IN ALL APPLICABLE CODE REQUIRED LOCATIONS.
2. ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHER
JURISDICTIONAL AND UTILITY APPROVED ASSOCIATION OR NATIONALLY
RECOGNIZED ORGANIZATION.
3. FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPLICABLE CODES LISTED
IN GOVERNING CODES SECTION, ALL MANUFACTURES' LISTINGS, INSTALLATION
INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS.
JURISDICTIONAL & LISTING REQUIREMENTS
4. REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCAL
JURISDICTION IF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES
NOT MATCH THE APPROVED BUILDING PLANS. ADDITIONAL FEES MAY ALSO
APPLY.
5. THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDED
AND PLACED BY THE CONTRACTOR AS PER APPLICABLE UTILITY OR AHJ
REQUIREMENTS.
MSP RATINGS
COMBINER(S)
AZIMUTH
TILT
ROOF COVERING RELEASEREVDATENAMECOVERSHEETAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSNORTH
⅊
⅊
⅊
⅊DRIVEWAY℄
℄
℄
℄
J E W E T T S T
FORBES AVEN/A
VB
5.200 KW
PV-001 COVER SHEET
Bond, Howard
Jesse Brekelbaum
2015
National Grid
20152015
21134A
(413) 584-8844
2023
Lilian Wanjiku(413) 588-8185 City of Northamptonproduction@valleysolar.solar
50507
Civil
(202) 874-3483swyssling@wysslingconsulting.com
R-3
II
Exposure C
40
Scott E. Wyssling
76 North Meadowbrook Dr(413) 588-8185 Alpine, UT 84004production@valleysolar.solar
Bond, Howard25 Forbes Ave, Northampton, MA 01060
ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED
W/O BATTERY STORAGE
340 Riverside Dr
Valley Solar
Florence, MA 01062
REC400NP3 Black
Enphase IQ8PLUS-72-2-US
IronRidge XR100 Rail
IronRidge FlashVue FV-01-M1
INTEGRATED IN INV
N/A
13
13
N/A
26
N/A
N/A
N/A
(E)
GPS COORDINATES (42.322823,-72.64835)
3.900 KW
1
120/240V - 1
43.4°
222°
117
Comp Shingle
N-001 GENERAL NOTES
PV-100R PV ARRAY LAYOUT
S-100 RACKING LAYOUT
S-200 SECTION ELEVATION
S-201 ATTACHMENT DETAILS
E-001 EQUIP. CALCULATIONMETER NUMBER:E-002 WIRE AND COND. CALCS
E-003 THREE LINE DIAGRAM
E-100 ELECTRICAL LAYOUT
P-001 STANDARD PLACARDS
P-002 DYNAMIC PLACARDS
R-1xx EQUIP.CUT SHEETS
N/A
200A BUS/200A MAIN BREAKER
BACK-FED BREAKER PV-001ASCE 7-10 WIND SPEED:Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88445.200Bond, Howard25 Forbes AveNorthampton, MA 0106012/20/2022SUBMIT FOR PERMIT102/02/2023ROOF ATTACHMENT2/3/2023
RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSGENERALNOTESGENERAL NOTES:*
PROPER ACCESS AND WORKING CLEARANCE AROUND
EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE
PROVIDED AS PER SECTION NEC 110.26.
PV SYSTEM COMPONENTS; INCLUDING BUT NOT LIMITED
TO, MODULES, INVERTERS AND SOURCE CIRCUIT
COMBINERS ARE IDENTIFIED AND LISTED FOR USE IN PV
SYSTEMS IN COMPLIANCE WITH NEC 690.4 AND 690.6
AND ALL UL, IEC, IEEE CLASSIFICATIONS AS
REQUIREMENTS.
RAPID SHUTDOWN NOTES:*
PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDIDNG
SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT
CONTROLS SPECIFIC PV CONDUCTORS IN ACCORDANCE
WITH 2023 NEC 690.12(A)-(D)
EQUIPMENT LOCATIONS &