Loading...
24C-145 (3) BP-2023-0302 15 ARLINGTON ST COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 24C-145-001 CITY OF NORTHAMPTON Permit: Solid Fuel Appliance PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit # BP-2023-0302 PERMISSION IS HEREBY GRANT D TO: Project# PELLET SOTVE 2023 Contractor: License: Est. Cost: DOUGLAS L'ABBEE CSL99401 Const.Class: Exp.Date: 01/06/2024 Use Group: Owner: SCHWEITZER WAYNE A Lot Size (sq.ft.) Zoning: URB Applicant: THE FIRE PLACE Applicant Address Phone: Insurance: 100 STATE RD (413)397-3463 WHATLEY, MA 01093 ISSUED ON: 03/10/2023 TO PERFORM THE FOLLOWING WORK: PELLET STOVE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: • n ' Fees Paid: $40.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner R EC -- \i_ City of Northampton u. Massachusetts t' L ` * ;c e,.. i I R - 9 2023 ti-15 DEPARTMENT OF BUILDING INSPECTIONS w.�°• "; :�a v -'..,-,. .":,._:.::;- Northampton,.` 212 Main Street • Municipal Building yJ ±'e` MA 01060 ssi%� 1� OF BUILDING INSPECT'C''1'. �n� NORTHAMPTON,MA O1(�I APPLICATION FOR SOLID FUEL APPLIANCE INSTALLATION Property Information Owners Name: /"c.y n c Se/jc;/ -y Address: /s gr//r?i'u.ii sit Aoi1Aenp far) 00- / (No.) (Street Address) Phone: Y'/3-Y '• (CO' \Cell: Email: Owners Signature: �1' Date: ZI l3l_23 Contractor's Information (If Applicable) Name: Oouti/zs Z PiLhcc- % '/c7)l¢cc. Phone: (//3 3 ?7 3Ve 3 Construction Supervisor's License #: 9?Vai Expiration: 7-e'-- / Home Impr. Contractor License #: /re-1177 Expiration: //- /8 a/ Stove Information Type of Fuel (check all that apply): Wood Pellet V Coal Location: rrsi ./ocr- Freestanding Y Insert Manufacturer: NPia•0 Model: c'3-C- eenn4.f 7 i— ntc,/ cArnt nc y a/rtoy ins�J/c 0— ien/cer, " '4xo r) 57r'r . --- ----------------FOR BUILDING DEPARTMENT USE ONLY Permit# 3 ' 0 e7 Date Applied: Total all Fees: $ y0 It'�f 3 Building Official: (Eu i t--► i Ko 5) Date Issued: 3-10_ZO Z 3 (Print) Signature of Building Official: ���5 Pry The Commonwealth of Massachusetts .. -- 1,=Ft�,s Department of Industrial Accidents =�:11f� 1 Congress Street, Suite 100 t<` Boston, MA 02114-2017 C1A�M .�,S www mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual): THE FIRE PLACE Address: 100 STATE ROAD City/State/Zip: WHATELY , MA 01093 Phone#:413-397-3463 Are you an employer?Check the appropriate box: Type of project(required): 1.❑✓ I am a employer with 10 0 employees(full and/or part-time)." 7. Ej New construction 2.0 l am a sole proprietor or partnership and have no employees working for me in 8. 0 Remodeling any capacity.[No workers'comp.insurance required.] 30I am a homeowner doing all work myself.[No workers'comp.insurance required.]t 9. ❑Demolition 10 Q Building addition 4.0 I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or arc sole ME Electrical repairs or additions proprietors with no employees. 12.Q Plumbing repairs or additions 5.0 I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13. p ❑Roof repairs These sub-contractors have employees and have workers'comp.insurance.t 6.❑We are a corporation and its officers have exercised their right of exemption per MGL c. 14.Q Other 152,§1(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:MA RETAIL MERCHANTS GROUP INC Policy#or Self-ins.Lic.#:01400503301116 Expiration Date:1-1-24 Job Site Address: /s /9r//v 7/ei>1 LSI City/State/Zip: /V ef1'Anrr,/rJr) — Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certif under the pains and pee hies ofperjury that the information provided above is true and correct. Signature: r / p` o' e Date: - ‘'a3 Phone#:413-397-3463 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: V 3 Clearances A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. P43-C Freestanding Pellet Stove P61-C Freestanding Pellet Stove r T -,.., "Outside Outside , Air Intake "` Air Intake N Ii -- E� �� .47�1`J3iosI�_--f �IIim 1 kii). III 1 I t M fMi's I i I 51/8" . 51/8" -. 22" a 23 1/2" • t e e iritii ZA CO N rn - ;, 'II D .111 III 20 3/4" P68-C Freestanding Pellet Stove ti Outside ke �OutsiAir e 11 141) \_,A.,6 •I. I---_ 5 1/4" 23-1/2" r e e a ' `` r vvvvv vvv r*. ?. 00 M O% N E`I I I 6 I r. Figure 3.1 8 Harman® • P-Series Installation Manual_R4 • 2018- • 04/21 8390-0441 VB. Clearances to Combustibles Place the stove away from combustible walls at least as far When selecting a location for the appliance it is important to as shown in Figure 3.2. Please note the difference in side consider the required clearances to walls, Figure 3.2. wall clearance with and without side shields. Note that the clearances shown are minimum for safety but do A WARNING not leave much room for access when cleaning or servicing. Please take this into account when placing the stove. RISK OF FIRE OR BURNS! Provide adequate Due to high temperatures, the stove should be placed out of clearance around air openings and for service traffic and away from furniture and draperies. access. Due to high temperatures, the appliance should Children and adults should be alerted to the hazards of high be located out of traffic and away from furniture and surface temperatures and should stay away to avoid burns draperies. to skin and/or clothing. Young children should be carefully supervised when they are ACAUTION in the same room as the stove. Clothing and other flammable materials should not be placed THIS APPLIANCE MUST BE VENTED TO THE OUTSIDE. on or near this unit. NOTICE:Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.Actual installation may vary due to individual design preference. P61-C & P68-C Freestanding Pellet Stove P43-C Freestanding Pellet Stove -- r - 2"(51mm) 2"(51mm) 14"(355mm)with ` F `10"(254mm)with side shields 411111 +, ' side shields zAmmirL ' 20"(508mm) `16"(406mm) without side shields o 14"(355mm) without side shields o *10"(254mm) ill- 20"(508mm) :16"(406mm) ME- 36"(914mm) 36"(914mm) 9"(228mm)- 9"(228mm) _ 13"(330mm) Ni. 4p \41111. W� v CO W W N co 9"(228mm)With Side Shields 3 13"(330mm) Without Side Shields 3 9"(228mm) With or Without Side Shields I Figure 3.2 9 Harman® • P-Series Installation Manual_R4 • 2018- • 04/21 8390-0441 C. Floor Protection Corner Installation: Parallel Installation: Minimum size floor protection for a corner installation hearth pad is: Place the stove on a noncombustible type floor or floor protector that extends a minimum of 6 inches (152mm) to P43-C - Minimum size floor protection is 25-7/16" Wide by the front of the load door opening, 6 inches (152mm)to the 26-3/4" Deep (646mm X 680mm). sides of the door opening, and 6 inches to the rear. P61-C - Minimum size floor protection is 25-1/8" Wide by The P-Series does not require R value floor protection. 27-3/4" Deep (638mm X 705mm). The minimum floor protector material is 20 gauge sheet metal. P68-C Minimum size floor protection is 25-3/16" Wide by Other floor protector materials that can be used include Type 27-3/4" Deep (640mm X 705mm). I hearth pads, ceramic tile, stone, brick, etc. Figure 3.3 Note: Floor protector WILL NOT touch the wall using *Floor protection dimensions for the front and sides are minimum clearances. measured from the appliance door opening in The United If corner floor protection is desired to touch the wall, the States. In Canada,the side dimension is measured from the floor protection will need to be at least 40" x 40" (1016mm widest part of the appliance. x 1016mm). Note: This will allow the floor protection to P43-C - Minimum size rectangular floor protection is 25 touch the wall as shown. Figure 3.4. 7/16" Wide by 26-3/4" Deep (646mm X 680mm). Alternate floor protector dimension may be used as long as P61-C-Minimum size rectangular floor protection is 25-1/8" they satisfy the measurement requirements shown below. Wide by 27-3/4" Deep (638mm X 705mm). P68-C - Minimum size rectangular floor protection is 25- 3/16"Wide by 27-3/4" Deep (640mm X 705mm). Venting: US-Follow PL vent manufacturers recommendations when configuring vent pipe installation. Canada - Must extend 2" (51 mm) beyond each side of any \ horizontal flue pipe. L 0 111 Figure 3.4 D. Mobile Home Installation When installing this unit in a mobile home, several 1111.M- requirements must be followed: J Floor Protector 1. The unit must be bolted to the floor. This can be done K using an appropriate fastener for the application. Figure 3.3 2. The unit must also be connected to outside air. See "Termination Location and Vent Information" Section D. Floor Protection US Canada 3. Floor protection and clearances must be followed as Requirements shown. J Sides 6" 152mm 4. The appliance must be properly grounded to the frame of K Front 6" 152mm the mobile home using a minimum of 8 AWG copper solid L Rear 6" 152mm or stranded, insulated or bare wire or equivalent. 10 Harman® • P-Series Installation Manual R4 • 2018- • 04/21 8390-0441