Conz, Mark - Ver 0.07 pt AR SS (1)GO VERNING CODESPARCELMAP PROJECT LOCATION SHEET INDEX ENGINEERED BY: CONTRACTOR: CONTRACTOR LIC #: PHONE: CONTACT NAME: PHONE: EMAIL: DESIGN BY: PHONE: HOME OWNER PROJECT LOCATION: PROJECT DRAFTER: LICENSE #: PHONE: ELECTRICAL UTILITY: AUTHORITY HAVING JURISDICTION: BUILDING: CONTACT NAME:PHONE: LICENSE TYPE: PHONE: EMAIL: EMAIL: PHONE: SHEET SHEET TITLE EMAIL:AdvancedSolarSolutions 2372MorseAve#912 Irvine, CA 92614 PHONE:559-321-7000EMAIL:info@advpermits.com PROJECT APN: GENERAL PROJECT & JURISDICTIONAL NOTES 1. UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSED WRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR SOLUTIONS IS A VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTION. APPLIC ABLE BUILDING CODES: INTERNATIONAL BUILDING CODE INTERNATIONAL RESIDENTIAL CODE INTERNATIONAL FIRE CODE NATIONAL ELECTRIC CODE DESIGN CRITERIA BUILDING OCCUPANCY: RISK CATEGORY: EXPOSURE CATEGORY: SNOW LOAD: SNOW EXPOSURE: CONSTRUCTION TYPE: SCOPE OF WORK NUMBER PROPOSED SOLAR EQUIPMENT SITE / PROJECT DETAILS QTY. EQUIPMENT DESCRIPTION/MFG/MODEL MODULES #1 INVERTER(S) MOUNTING STANCHIONS RSD DEVICE MODULES #2 SYSTEM SIZE DC SYSTEM SIZE AC QTY. STRING/CKT. ELECT. SERVICE PROJECT TEAM LIST COPYRIGHT NOTICE 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH ALL OSHA REGULATIONS. 2. PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLE ALL ELECTRICAL ENCLOSURE DEAD FRONTS, COVERS, DOORS, ETC. SHALE BE OPEN AND ACCESSIBLE FOR INSPECTIONS. WHEN TRENCH AND ROOF INSPECTIONS ARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOR INSPECTOR. INSPECTION REQUIREMENTS 1. WHEN APPLICABLE A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL OR ANSI/UL 217 CERTIFIED TO NATIONAL FIRE ALARM AND SIGNALING CODE, NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED IN ALL APPLICABLE CODE REQUIRED LOCATIONS. 2. ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHER JURISDICTIONAL AND UTILITY APPROVED ASSOCIATION OR NATIONALLY RECOGNIZED ORGANIZATION. 3. FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPLICABLE CODES LISTED IN GOVERNING CODES SECTION, ALL MANUFACTURES' LISTINGS, INSTALLATION INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS. JURISDICTIONAL & LISTING REQUIREMENTS 4. REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCAL JURISDICTION IF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES NOT MATCH THE APPROVED BUILDING PLANS. ADDITIONAL FEES MAY ALSO APPLY. 5. THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDED AND PLACED BY THE CONTRACTOR AS PER APPLICABLE UTILITY OR AHJ REQUIREMENTS. MSP RATINGS COMBINER(S) AZIMUTH TILT ROOF COVERING RELEASEREVDATENAMECOVERSHEETAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSNORTH ⅊⅊ ⅊ ⅊ PARK HILL RD DRIVEWAY N/A VB 10.535 KW PV-001 COVER SHEET Conz, Mark Jesse Brekelbaum 2015 National Grid 20152015 21134A (413) 584-8844 2023 Lilian Wanjiku(413) 588-8185 City of Northamptonproduction@valleysolar.solar 50507 Civil (202) 874-3483swyssling@wysslingconsulting.com R-3 II Exposure C 40 Scott E. Wyssling 76 North Meadowbrook Dr(413) 588-8185 Alpine, UT 84004production@valleysolar.solar Conz, Mark42 Park Hill Rd, Northampton, MA 01062 ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED W/O BATTERY STORAGE 340 Riverside Dr Valley Solar Florence, MA 01062 REC365NP2 Black SolarEdge SE7600H-US (240V) Ironridge AIRE RAIL A1 IronRidge FlashVue FV-01-M1 INTEGRATED IN INV & OPT REC400NP3 BLACK 19 1 N/A 77 N/A 9 N/A (E) GPS COORDINATES (42.299385,-72.67524) 7.600 KW 3 120/240V - 1 22.6° 161°,251° 117 Comp Shingle N-001 GENERAL NOTES PV-100R PV ARRAY LAYOUT S-100 RACKING LAYOUT S-200 SECTION ELEVATION S-201 ATTACHMENT DETAILS E-001 EQUIP. CALCULATIONMETER NUMBER:E-002 WIRE AND COND. CALCS E-003 THREE LINE DIAGRAM E-100 ELECTRICAL LAYOUT P-001 STANDARD PLACARDS P-002 DYNAMIC PLACARDS R-1xx EQUIP.CUT SHEETS N/A 200A BUS/200A MAIN BREAKER LINE-SIDE TAP PV-001ASCE 7-10 WIND SPEED:Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT2/15/2023 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSGENERALNOTESGENERALNOTES:* PROPERACCESSANDWORKINGCLEARANCEAROUND EXISTINGANDPROPOSEDELECTRICALEQUIPMENTWILLBE PROVIDEDASPERSECTIONNEC110.26. PVSYSTEMCOMPONENTS;INCLUDINGBUTNOTLIMITED TO,MODULES,INVERTERSANDSOURCECIRCUIT COMBINERSAREIDENTIFIEDANDLISTEDFORUSEINPV SYSTEMSINCOMPLIANCEWITHNEC690.4AND690.6 ANDALLUL,IEC,IEEECLASSIFICATIONSAS REQUIREMENTS. RAPIDSHUTDOWNNOTES:* PVSYSTEMCIRCUITSINSTALLEDONORINBUILDIDNG SHALLINCLUDEARAPIDSHUTDOWNFUNCTIONTHAT CONTROLSSPECIFICPVCONDUCTORSINACCORDANCE WITH2023NEC690.12(A)-(D) EQUIPMENTLOCATIONS&ELECTRICAL NOTES:* JUNCTIONANDPULLBOXESAREPERMITTEDTOBE INSTALLEDUNDERPVMODULESINCOMPLIANCEWITH NEC690.34. ADDITIONALACDISCONNECT(S)SHALLBEPROVIDED WHERETHEINVERTERISNOTWITHINSIGHTOFTHEAC SERVICINGDISCONNECT.2023NEC690.15(A) ALLEQUIPMENTSHALLBEINSTALLEDACCESSIBLETO QUALIFIEDPERSONNELINCOMPLIANCEWITHNEC APPLICABLECODES. ALLCOMPONENTSARELISTEDFORTHEIRINTENDED PURPOSEANDRATEDFOROUTDOORUSAGEWHEN APPLICABLE. STRUCTURALANDINSTALLATION NOTES:* RACKINGSYSTEM&PVPANELSMOUNTEDONA ROOFTOPSHALLBELISTEDANDLABELEDINACCORDANCE WITHUL1703ANDSHALLBEINSTALLEDINACCORDANCE WITHTHEMANUFACTURERINSTALLATIONINSTRUCTIONS. ALLPVRACKINGATTACHMENTPOINTSSHALLNOTEXCEED THEPRE-ENGINEEREDMAXSPANSOUTLINEDBYTHE RACKINGMANUFACTURESENGINEEROFRECORD. GROUNDINGNOTES:* INUNGROUNDEDSYSTEMSONLYTHEDCCONDUCTORS AREUNGROUNDEDANDREQUIREANEQUIPMENT GROUNDINGCONDUCTOR.ALLMETALELECTRICAL EQUIPMENTANDSTRUCTURALCOMPONENTSBONDEDTO GROUND,INCOMPLIANCEWITHNEC250.134ANDNEC 250.136(A). PVEQUIPMENTINCLUDINGMODULEFRAMESANDOTHER METALPARTSSHALLBEGROUNDEDINCOMPLIANCE WITHNEC690.43ANDMINIMUMGROUND CONDUCTORSSIZEDINACCORDANCEWITHNECTABLE 250.122. CONDUCTIVEPARTSOFMODULEFRAMES,MODULE RACKING,ANDENCLOSURESSHALLBEGROUNDEDIN COMPLIANCEWITHNEC250.134ANDNEC250.136(A). UL2703APPROVEDMODULEANDRACKGROUNDING SHALLBEUSEDANDINSTALLEDPERMANUFACTURER'S INSTALLATIONMANUAL.IFUL2703APPROVED GROUNDINGISNOTUSED,MODULEGROUNDINGLUGS MUSTBEINSTALLEDATTHESPECIFIEDGROUNDINGLUG HOLESPERTHEMANUFACTURER'SINSTALLATION REQUIREMENTS. THEGROUNDINGCONNECTIONTOAMODULESHALLBE ARRANGEDSUCHTHATTHEREMOVALOFAMODULEDOES NOTINTERRUPTAGROUNDINGCONDUCTORTOANOTHER MODULE. THEGROUNDINGELECTRODESYSTEMCOMPLIESWITH NEC690.47ANDNEC250.50THROUGHNEC250.106. IFEXISTINGSYSTEMISINACCESSIBLEORINADEQUATE,A GROUNDINGELECTRODESYSTEMWILLBEPROVIDEDIN COMPLIANCEWITHNEC250,NEC690.47ANDAHJ. PVSYSTEMSSHALLBEPROVIDEDWITHDCGROUND- FAULTPROTECTION2023NEC690.41(B) INTERCONNECTION/POCNOTES:* ALLLOAD-SIDEINTERCONNECTIONSAREINCOMPLIANCE WITH2023NEC705.12(B) THETOTALRATINGOFALLOCPDINSOLARLOADCENTERS SHALLNOTEXCEEDTHERATEDAMPACITYOFTHEBUSBAR EXCLUDINGTHEOCPDPROTECTINGTHEBUSBARIN COMPLIANCEWITHNEC705.12(B)(2)(3)(c) ALLFEEDERTAP(LOADSIDE)INTERCONNECTIONSAREIN COMPLIANCEWITH2023NEC705.12(B)(2)(1) THEPVSYSTEMBACK-FEEDBREAKERSHALLBEINSTALLED ONTHEOPPOSITEENDOFTHEBUSBARANDITSHALL ALSOBESIZEDAPPROPRIATELYASPER2023NEC 705.12(B)(2)(3)(b) SUPPLYSIDETAPINTERCONNECTIONS AREIN COMPLIANCEWITHNEC705.12(A)WITHSERVICE ENTRANCECONDUCTORSINCOMPLIANCEWITHNEC 230.42 BACKFEEDINGBREAKERFORINVERTEROUTPUTISEXEMPT FROMADDITIONALFASTENING2023NEC705.12(B)(5) MICROINVERTERBRANCHCIRCUITSSHALLBECONNECTED TOASINGLEOCPDINACCORDANCEWITHTHEIR INSTALLATIONINSTRUCTIONSANDNEC690.9 DISCONNECTSANDOCPDNOTES:* ALLDISCONNECTINGSWITCHESWILLBECONFIGUREDSO THATALLENERGIZEDCONDUCTORSWHENDISCONNECTIS OPENSHALLBEONTHETERMINALSMARKED,“LINESIDE” (TYPICALLYTHEUPPERTERMINALS) ALLACDISCONNECTSSHALLBELABELED,LOCKABLE,OF VISIBLEBREAKTYPESWITCHWITHEXTERNALHANDLEAND ACCESSIBLETOQUALIFIEDUTILITYPERSONNEL. ACDISCONNECTSSHALLBEA“KNIFEBLADE”TYPE DISCONNECT.IFEXTERIOR,RATEDTONEMA3RORBETTER PERNEC110.28 ADDITIONALACDISCONNECTSSHALLBEPROVIDED WHERETHEINVERTERISNOTADJACENTTOTHEUTILITY ACDISCONNECT,ORNOTWIHTINSIGHTOFTHEUTILITYAC DISCONNECT.2023NEC690.15(A) BOTHPOSITIVEANDNEGATIVEPVCONDUCTORSREMAIN UNGROUNDED.THEREFORE,BOTHSHALLREMAINOPEN WHEREADISCONNECTISREQUIREDINCOMPLIANCEWITH 2023NEC690.15(D) ALLOCPDRATINGSANDTYPESSPECIFIEDSHALLBEIN COMPLIANCEWITHNEC690.8,690.9,705.12AND240. BOTHPOSITIVEANDNEGATIVEDCPVCONDUCTORSARE UNGROUNDED;BOTHREQUIREOVERCURRENT PROTECTIONINCOMPLIANCEWITHNEC690.9 ARCFAULT(AFCI)DCCIRCUITPROTECTIONISREQUIRED FORALLPVSYSTEMSONORPENETRATINGABUILDING WITHAMAXIMUMSYSTEMVOLTAGEOF80VOLTSOR GREATER.ALLDCPVCIRCUITSINSTALLEDINORON BUILDINGSWILLBEARC-FAULTCIRCUITPROTECTEDIN COMPLIANCEWITHNEC690.11,UL1699BANDSHALLBE LISTEDANDLABELEDINACCORDANCEWITHUL1699(B). WIRING&CONDUITNOTES:* ALLCONDUITANDCONDUCTORSSHALLBEAPPROVED FORTHEIRINTENDEDPURPOSEINCLUDINGWET LOCATIONSANDEXPOSEDTOSUNLIGHT.CONDUITAND CONDUCTORSIZESPECIFICATIONSAREBASEDONTHE MINIMUMCODEREQUIREMENTSANDARENOTLIMITED TOUPSIZING. ALLCONDUCTORSSHALLBESIZEDINCOMPLIANCEWITH NEC690.8,NEC690.7. ALLCONDUCTORSSHALLBEDERATEDASAPPLICABLETO THEIRRESPECTIVEENVIRONMENTINCLUDINGDIRECT SUNLIGHTINACCORDANCEWITH2023NEC 310.15(B)(3)(4)(c) EXPOSEDUNGROUNDEDDCPVSOURCEANDOUTPUT CIRCUITSSHALLUSECONDUCTORSLISTEDANDIDENTIFIED ASPHOTOVOLTAIC(PV)WIREINCOMPLIANCE2023NEC 690.31(C)(1).PVMODULESWIRELEADSSHALLBELISTED FORUSEWITHUNGROUNDEDSYSTEMSINCOMPLIANCE WITH2023NEC690.4(B) PVWIREBLACKWIREMAYBEFIELD-MARKEDWHITEIN COMPLIANCEWITHNEC200.6(A)(6). PVMODULECONDUCTORSLOCATEDUNDERARRAYSWILL BESECUREDINAWORKMANLIKEMANNERIN COMPLIANCEWITHNEC110.12. WATERPROOFING:* ALLNEWROOFTOPPENETRATIONSSHALLBESEALEDAND MADEWEATHERTIGHTWITHAPPROVEDCHEMICAL SEALANTANDFLASHINGSWHEREREQUIREDPERCODE ANDGENERALBUILDINGANDROOFINGWORKMANSHIP STANDARDSBYALICENSEDCONTRACTOR. ALLEXTERIORELECTRICALEQUIPMENT,SHALLBENEMA 3RORBETTERRATED.ALLEXTERIORCONDUITAND CONNECTORSSHALLBERATEDFORWETLOCATIONS. *ALLNOTESAREASAPPLICABLETOTHISPROJECT. DISREGARDANYNOTESTHATDONOTAPPLYTOTHIS PROJECT. INTHISPLANSET ARECALCULATEDONCIRCUITS50’INLENGTHORLONGER, THETOTALVOLTAGEDROPFROMINVERTERTOPOINTOF CONNECTIONORUTILITYTRANSFORMERARENOT CALCULATED.ELECTRICALCONTRACTORMUSTEVALUATE ANDFIELDVERIFYINVERTERMANUFACTURESMAXVOLTAGE DROPREQUIREMENTSANDDETERMINETHETOTALVOLTAGE DROPWITHINCIRCUITSASDIRECTEDBYMANUFACTURER ANDCOMPLYWITHSUCHLIMITATIONSANDREQUIREMENTS, (TYPICALLY2%FROMINVERTERTOPOI/POC,AND3%FROM INVERTERTOUTILITYTRANSFORMER.)N-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT2/15/2023 2015 IFC ROOF ACCESS REQUIREMENTS PV SITE LAYOUT LEGEND *EXISTING DIMENSIONS ARE APPROX. CONFIRM ALL DIMENSIONS SHOWN PVARRAYLAYOUTSQUARE FOOTAGE CALCULATIONS ROOF REFERENCE SQUARE FOOTAGE TOTAL PERCENTAGE AZIMUTH ANDTILTTABLE SECTION #AZIMUTH ROOF PITCH /TILT EXISTING ROOF SECTION 1 ROOF ACCESS POINT SITE ACCESS GATE ACCESS SECTION 1 PV ARRAY TAG SECTION #MODULE GROUP RA SA GA NOTE: ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSNORTH SECTION 1 SECTION 2 SECTION 3 RA RA THIS SHEET REPRESENTS THE SOLAR MODULE LAYOUT ON ROOFTOP. SHADED DASHED LINE NEAR PERIMETER OF STRUCTURE EXTERIOR IS PHOTOVOLTAIC MODULES ARE SCALED IN PLAN VIEW AND MAY NOT BE AN ACCURATELY SCALED REPRESENTATION OF THE ACTUAL SCALE AND GEOMETRY OF THE PHOTOVOLTAIC MODULE. ACTUAL PHOTO- VOLTAIC MODULE DIMENSIONS ARE ON SHEET E-001 FOR THE PURPOSE OF CLARITY, ALL ELECTRICAL LAYOUT DETAILS ARE LOCATED ON SHEET E-100. A. B. C. AN APPROXIMATE REPRESENTATION OF THE EXTERIOR WALL LOCATION PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER SCALE: 1/8” = 1’0” @ SHEET SIZE A3 1984SECTION-1 373 28.48% 161 22.6°SECTION-1 251 22.6°SECTION-2SECTION-3 161 22.6° 43 149SECTION-2 SECTION-3 QTY 19 REC365NP2 Black MODULES QTY 9 REC400NP3 Black MODULES QTY 1 SolarEdge SE7600H-US (240V) INVERTER PV-100RValley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT2/15/2023 SHEET NOTES *EXISTING ROOF DIMENSIONS ARE APPROX. CONFIRM ALL DIMENSIONS SHOWN PV RACKING LEGEND RACKINGLAYOUTRACKING BILL OF MATERIALS (BOM) COMPONENT QTY MODEL LENGTH PV RAIL 1 PV RAIL SPLICE 1 PV RAIL 2 PV RAIL SPLICE 2 RAILTOROOFATTACHMENT EXISTING ROOF CONSTRUCTION COMPONENT TYPE ROOF STRUCTURALCONSTRUCTION ROOFIN G COVERING RACKING MAX PSF ROOF RACKING RAIL SPLICE ROOF RACKING STANCHION W/RETRO FIT FLASHING *DETAILS IN TOP VIEW SECTION 1 PV ARRAY TAG SECTION #MODULE GROUP B. ANCHOR SPACING SHOWN IN DETAIL.UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS.SEE "TABLE OF DIMENSIONS"EACH SECTION DETAILED FOR HORIZONTAL ANCHOR SPACING. C.SEE SHEET S-200 FOR SPECIFIC RACKING COMPONENT MANUFACTURERS. FRAMING INFO ROOF RACKING RAIL RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSNORTH 34'-1"14'-11"11'-6"19'-5"5'-9"6'-10" REC365NP2 BLACK REC400NP3 BLACK REC400NP3 BLACK 2"x6" @ 16" MAX OC 2"x10" @ 16" MAX OC 2"x10" @ 16" MAX OC SCALE: 1/8” = 1’0” @ SHEET SIZE A3 Rafter-Simple Attic 16" O.C. 2"x6" & 2"x10"@ 16" MAX OC Comp Shingle 2.82 PSF QTY 19 REC365NP2 Black MODULES QTY 9 REC400NP3 Black MODULES QTY 1 SolarEdge SE7600H-US (240V) INVERTER S-100A. FOR MANUFACTURED PLATED WOOD TRUSSES AT SLOPES OF FLAT TO 6:12, THE HORIZONTAL ANCHOR SPACING SHALL NOT EXCEED 4’-0” AND ANCHORS IN ADJACENT ROWS SHALL BE STAGGERED. UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS.Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT2/15/2023 SHEET NOTES PV RACKING LEGEND 21SCALE:NTS 3 4 A.THESE NOTES APPLY TO RAFTER ROOF CONSTRUCTION. B.THE ROOF STRUCTURE CONFORMED TO BUILDING CODE REQUIREMENTS AT THE TIME IT WAS BUILT. C. STRAND BOARD OR PLYWOOD.1X SKIP SHEATHING IS ACCEPTABLE. D.THE SOLAR ARRAY DISPLACES ROOF LIVE LOADS (TEMPORARY CONSTRUCTION LOADS)THAT THE ROOF WAS ORIGINALLY DESIGNED TO CARRY. E.IF THE ROOF COVERING IS SHINGLES;IT SHALL BE NO MORETHANTWOLAYERS.(SHOWN) F.IF ROOF COVERING IS TILE;ITS A SINGLE LAYER.ALL TILES ON PLANE OF PV COMPONENTS ARE SECURE. (NOT SHOWN IN DETAIL) G.THE ROOF STRUCTURE IS STRUCTURALLY SOUND,WITHOUT SIGNS OF ALTERATIONS OR SIGNIFICANT STRUCTURAL DETERIORATION OR SAGGING. H.THE PV MODULES ARE PARALLEL WITH THE ROOF SURFACE. I. AND THE ROOF SURFACE.(SEE TABLE OF DIMENSIONS "H1") J.UPSLOPE ANCHOR SPACING MAY VARY FROM LISTED TABLES. STANCHIONS CAN BE PLACED NO CLOSER THAN 24"O.C. K. # SCALE:NTS SCALE:NTSSCALE:NTS SECTIONELEVATIONSTABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT.ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX.STANCHION O.C. TABLE OF COMPONENTS COMPONENT MODEL 1 PV RAIL TYPE 1 2 PV RAIL SPLICE TYPE 1 3 PV RAIL TYPE 2 4 PV RAIL SPLICE TYPE 2 5 STANCHION 6 FLASHING 7 MID CLAMP 8 END CLAMP EXISTING ROOF CONSTRUCTION COMPONENT TYPE MEAN ROOF HGT MAX ROOFIN G COVERING TABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT.ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX.STANCHION O.C. *DETAILS IN SECTION OR SIDE VIEW ROOF RACKING RAIL SPLICE ROOFRACKING STANCHIONW/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION# MODULE GROUP PER RAIL MANUFACTURER MAX RAFTER SPANMAXRAFTERSPAN L. DETAILS SHOWN ARE A REPRESENTATION OF EXISTING ROOFCONDITIONS.ACTUAL FIELD CONDITIONS MAY VARY.DETAILSARE SHOWN FOR DIAGRAM USE ONLY.REFER TO TABLES FORDESIGN CRITERIA. ALL PLUMBING AND ROOF VENTS SHALL NOT BE OBSTRUCTEDBYPVMODULESANDEQUIPMENT. M. ROOF RACKING RAIL RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANS*IF BLOCKING REQUIRED32 S-201 1 S-201 HORIZONTAL SPAN 12 RIDGE BEAM FRAMING 1 5 6 7 RISE 3 OH1HS1 PV1 D3 D2 D1 D2H1R2R1 **COMP SHINGLE ROOF IN EXAMPLE.SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. *IF BLOCKING REQUIRED32 S-201 1 S-201 HORIZONTAL SPAN 12 RIDGE BEAM FRAMING 1 5 6 7 RISE 3 OH1HS1 PV1 D3 D2 D1 D2H1R2R1 **COMP SHINGLE ROOF IN EXAMPLE.SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. BOLTLAG5/16X4.25" 2.5"MINEMBEDMENT GRIPCAP IRONRIDGEFMFLASHING (E) RAFTER@16"O.C.TYPICAL 1'-4"TYP 4'-0"MAX SIMPLE ATTIC / RAFTER - PORTRAIT SIMPLE ATTIC / RAFTER - LANDSCAPE EXPLODED STANCHION & FLASHING DETAIL STANCHION SPACING DETAIL AIRE RAIL A1 FlashVue FV-01-M1 Integrated 22.6° 3" - 6" TYP 10.23" 20.45" 20.7" 6"&10"22.6° 3" - 6" TYP 17.27" 34.55" 34.8" 6"&10" 25' Comp Shingle NOT USED 14'-4" MAX 14'-4" MAX S-200PER RAIL MANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT2/15/2023 SHEET NOTES PV RACKING LEGEND *DETAILS IN SECTION OR SIDE VIEW 1.(1) ENGINEERING. 2.ADHERE TO RACKING MANUFACTURERS INSTALLATIONINSTRUCTIONS PERTAINING TO CANTILEVER. 21SCALE:NTS 3 4 SCALE:NTS SCALE:NTSSCALE:NTS ATTACHMENTDETAILSROOF RACKING RAIL SPLICE ROOF RACKING STANCHION W/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION# MODULE GROUP ROOF RACKING RAIL RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANS1/3"OF TOTAL SPAN MAX 2/3"OF TOTAL SPAN MAX RAIL MANUFACTURER RAIL SPLICE KIT SEE "S-100 /TABLE OF COMPONENTS" SPACING VARIES STAGGER STANCHIONS WHERE POSSIBLE. SEE SHEET "S-100"FOR: HORIZONTAL ANCHOR SPAN SPACING. (E)FRAMING TYPICAL *MODULES SHOWN PORTRAIT IN EXAMPLE DC AND/OR 1/3 CANT. MAX COMPONENT + 2"FROM SIDE OF MODULE 2" ROOF TOP CONDUIT EXTENSION OF RAIL RAIL OR STRUT CONNECTIONS TO MEET WEIGHT REQ.OF EQUIPMENT DCB *MODULES SHOWN PORTRAIT IN EXAMPLE**RAILING SHOWING IN VERTICAL IN EXAMPLE RIDGE BEAM *R2*R1VERIFY THAT NO DIAGONAL AND/OR VERTICAL ATTIC/FRAMING STRUT MEMBERS ARE CUT OR NOTCHED *SEE DETAILS "1-2/S200"TABLE OF DIMENSIONS HOLESALLOWEDONLYIN MIDDLEHALFOFFRAMINGSPAN 1/4 1/4 HOLES ALLOWED ONLY IN MIDDLE THIRD OF FRAMING DEPTH,*R2,AND NO LARGER THAN *R2/4 IN DIAMETER.MINIMU M SPACING BETWEEN HOLES AT *R2 FRAMING SAG IN INCHES NOT TO EXCEED FRAMING LENGTH IN FEET DI VIDED BY 20 NOTCHES DEEPER THAN 1/4" NOT ALLOWED ALONG TOP OR BOTTOM EDGE OF FRAMING NOTE:WHERE FRAMING IS VISIBLE FROM ATTIC &/OR UNDERSIDE OF ROOF, VISUALLY REVIEW FRAMING TO VERIFY THAT NO SIGNIFICANT STRUCTURAL DECAY OR UN-REPAIRED FIRE DAMAGE EXISTS. RIDGE SAG IN INCHES NOT TO EXCEED RID GE LENGTH IN FEET DIVIDED BY 20 MODULE END CLAMP 1/4" SS HCS BOLT (E) ROOF SHEATING /DECKING (E) BUILDING STRUCTURE IRONRIDGE AIRE RAIL A1 PV MODULE FLASHING IRONRIDGE FLASHVUE (W/ INTEGRATED FLASHING) CAP SCREW, 3/8"-16 X 1.75, CAPTIVE WASHER ALL ANCHOR LAGS TO BE MINIMUM 2-1/2"EMBEDMENT INTO FRAMING MEMBERS AIRE DOCK STANCHION ATTACHMENT DETAIL WITH FLASHING RAIL SPLICE DETAIL - HORIZONTAL RAIL RAIL EXTENTION DETAIL RAFTER HOLE AND CONSTRUCTION DETAIL S-201Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT2/15/2023 PV SYSTEM MAXIMUM VOLTAGE (MODULE #1VocMAX) DATA SOURCE SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/EXPEDITED-PERMIT/MAP/ EXTREME MIN. STC TEMPERATURE CORRECTEDTEMPERATURE MFR.PMAX TEMP COEFFICIENT [-0.#%/C]*100 FORMULA CORRECTED TEMP.COEFFICIENT MODULE Voc [VDC] TEMPERATURE CORRECTEDOPENCIRCUIT VOLTAGE - =*= +*= PV MODULE #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER WEIGHT Ibs DIMENSIONS L"x W"x D"/ PEAK POWER @ STC (Pmax)WATTS Voc (OPEN-CIRCU IT VOLTAGE)VOLTS DC Vmp (MAX-POWER VOLTAGE)VOLTS DC isc (SHORT-CIRCUIT CURRENT)AMPS imp (OPERATING CURRENT)AMPS MFR.Voc TEMP COEFFICIENT %/K MAX SERIES FUSE RATING AMPS TEMP.CORRECTED Voc VOLTS DC (IF APPL.) MANUFACTURER MODEL NUMBER WEIGHT Ibs RATED OUTPUT isc AMPS MAX OUTPUT VOLTAGE VOLTS MAX INPUT VOLTAGE Voc VOLTS DC COMBINER /DISCONNECT #1 MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENT DC INPUT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS QTY MAX PV MODULE Voc VOLTS DC MAX #OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE VOLTS DC MAX INPUT FUSE/BREAKER RATING AMPS DC OUTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT.OUTPUT CURRENT AMPS STRING INVERTER #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs. DC INPUT Max INPUT DC VOLTAGE VOLTS DC Min.MPPT VOLTAGE RANGE VOLTS DC Max.MPPT VOLTAGE RANGE VOLTS DC Max INPUT CURRENT AMPS MPPT QTY INTEGRATED DC DISCONNECT COMPLY W/NEC 690.17INTEGRATEDACDISCONNECT AC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX.OUTPUT CURRENT AMPS -MAX AC SUB-PANEL #1 (IF APPL.) NEW OR EXISTING MAKE /MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C.BREAKER AMPS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS PV BACKFEED BREAKER #1 AMPS (Imax) AMPS (Imax) MAIN SERVICE PANEL (IF APPL.) NEW OR EXISTING ELECTRICAL SERVICE BUSS BAR RATED CURRENT AMPS MAIN BREAKER RATED CURRENT AMPS AMPS AMPS AMPS (Imax) AMPS (Imax) THICK WATTSMAX.AC APPARENT POWER DC COMBINER /DISCONNECT #2 (IF APPL.) MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENT DC INPUT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS QTY MAX PV MODULE Voc VOLTS DC MAX #OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE VOLTS DC MAX INPUT FUSE/BREAKER RATING AMPS DC O UTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT.OUTPUT CURRENT AMPS QUANTITY STR ING INV ERTER #2 SPECIFICATIONS (IF APPL.) AMPS -MAX MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs. DC INPUT Max INPUT DC VOLTAGE VOLTS DC Min.MPPT VOLTAGE RANGE VOLTS DC Max.MPPT VOLTAGE RANGE VOLTS DC Max INPUT CURRENT AMPS MPPT QTY INTEGRATED DC DISCONNECT COMPLY W/NEC 690.17INTEGRATEDACDISCONNECT AC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCU RRENT PROTECTION (OCPD)AMPS MAX.OUTPUT CURRENT WATTSMAX.AC APPARENT POWER QUANTITY INVERTER(S) INVERTER(S) AC C OMBINER #1 (SO LAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CU RRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AC DISCONNECT #1 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) AC DISCONNECT #2 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPU T CURRENT QUANTITY AC DISCO.(S) PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #3 PV BACKFEED BREAKER #4 AMPS (Imax) AMPS (Imax) AC C OMB INER #2 (SO LAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AMPS (Imax) AMPS (Imax) AMPS (Imax) SUM OF EXISTING CIRCUIT BREAKERS AMPS (Imax) MAX ALLOWABLE SOLAR CURRENT 100% MAX ALLOWABLE SOLAR CURRENT 120% PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #3 PV BACKFEED BREAKER #4 ALT.ENERGY BACKFEED BREAKER (IF APPL.) SUM OF EXISTING CIRCUIT BREAKERS RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CALCULATIONSPV MODULE #2 SPECIFICATIONS MANUFACTURER MODEL NUMBER WEIGHT Ibs DIMENSIONS L"x W"x D"/ PEAK POWER @ STC (Pmax)WATTS Voc (OPEN-CIRCUIT VOLTAGE)VOLTS DC Vmp (MAX-POWER VOLTAGE)VOLTS DC isc (SHORT-CIRCUIT CURRENT)AMPS imp (OPERATING CURRENT)AMPS MFR.Voc TEMP COEFFICIENT %/K MAX SERIES FUSE RATING AMPS TEMP.CORRECTED Voc VOLTS DC THICK REC REC400NP3 Black 47.0 74.8 x 40.9 x 1.2 400 45.0 37.6 11.39 10.64 -0.26 25.0 50.4 PV SYSTEM MAXIMUM VOLTAGE (MODULE #2VocMAX) DATA SOURCE SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/EXPEDITED-PERMIT/MAP/ EXTREME MIN. STC TEMPERATURE CORRECTEDTEMPERATURE MFR.PMAX TEMP COEFFICIENT [-0.#%/C]*100 FORMULA CORRECTED TEMP.COEFFICIENT MODULE Voc [VDC] TEMPERATURE CORRECTEDOPENCIRCUIT VOLTAGE - =*= +*=-20 25 -45 -0.26%0.12 1 1.12 45 50.4 E-001REC Eaton DG222URB1REC365NP2 Black44.0 69.1 x 40.9 x 1.2 NON-FUSIBLE DISCONNECT120/240365 40.934.311.36 60 45.81 10.65 3R2 N/A 32-0.2625.0 SolarEdge Technologies S440 Single-HD (240V)1.5 1560 60 SolarEdge SE7600H-US (240V) 7600 26.2 480 400 48020 N/A Yes NO 240 7600 40 32 -20 25 -45 -0.26%0.12 1 1.12 40.9 45.81 1 EXISTING 120/240V Single Phase 200 200 040 DC/DC OPTIMIZER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT ≤ DC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE L INE DIAGRAM] TAG CIRCUIT ORIGIN CIRCUIT CONDUCTORSPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITY PER 310.16 MAXCURRENT 690.8 (A)(1) CONT.OPERATION 690.8 (B)(1) REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVE ROOF (in) TEMP. ADDER PER310.15 (B)(2)(c) OPERAT.TEMP. AMPACITY CORRECTION310.15 (B)(2)(a) #OFUNGRND.COND. AMPACITY CORRECTION310.15 (B)(3)(a) COND.AMPACITY TEMP.DERATING CONDUITFILL DERATINGXXX=XX=CORRECTEDAMPACITY REQUIREDAMPACITY CORRECTEDAMPACITY DC1 XXX=XX= DC2 XXX=XX= DC3 XXX=XX= DC4 XXX=XX= DC5 XXX=XX= AC WIRE AND CONDUIT FILL DERATE C HART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIR CUIT ORIGIN CIRCUITDESTINATION CONDUCTORSPECIFICATIONS REQUIRED CONDUCTORAMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER 310.16 CONT.OPERATION 690.8 (B)(1)X =REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVE ROOF (in) TEMP.ADDER PER310.15 (B)(2)(c) OPERAT. AMPACITYCORRECTION310.15 (B)(2)(a) #OFUNGRND.COND. AMPACITYCORRECTION310.15 (B)(3)(a) COND.AMPACITY X TEMP.DERATING X CONDUITFILLDERATING =CORRECTEDAMPACITY REQUIREDAMPACITY CORRECTEDAMPACITY AC1 X =X X = AC2 X =X X = AC3 X =X X = AC4 X =X X = AC5 X =X X = 1.ANY CONDUCTOR LENGTH UNDER 50'DOESN'T REQUIRE VOLTAGE DROP CALCULATIONS DEEMED QUESTIONABLE TO PREVENT ISSUES RELATED TO USING CONDUCTORS THAT ARE IMPROPERLY SIZED.3. 4.CEC/NEC 310.15(A)(2)(AS APPLICABLE)WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT,THE HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION,A DISTANCE EQUAL TO 10'-0"(3 METERS)OR 10%OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY,WHICHEVER IS LESS. WHEN LESS THAN 10'-0"OR 10%OF THE CIRCUI T LENGTH;THE LESSER AMPACITY MAY BE USED. PV DC WIRING AC WIRING 2.BECAUSE WE ARE UNABLE TO DETERMINE THE EXACT PATH THE INSTALLER WILL RUN CONDUCTORS;WORST CASE SCENARIOS,ROUNDING UP SIZES OF CONDUCTORS THAT ARE EQUIPMEN T GROUND GREEN OR BARE,OR GREEN/YELLOW (NEUTRAL)WIRING METHODS IN THESE CALCULATIONS DON'T EXCEED 1000 VOLTSGROUNDED CONDUCTORWHITE OR GRAY UNGROUNDED L1 AND L 2 ANY COLOR OTHER THAN GREEN OR WHITE/GRAY ALLOWED. CONDUCTOR(S)HOT:CONVENTION IS L1 BLACK CONVENTION IS L2 RED WIRE AND CONDUCTOR NOTES AC6 X =X X = AC7 X =X X = AC8 X =X X = AC9 X =X X = AC10 X =X X = DC6 X XX=XX = DC7 XX X=XX = DC8 XX X=XX = #OFCOMBINEDPARALLELSTRINGS DESTINATION QTY INPARALLEL & MATERIAL QTY INPARALLEL & MATERIAL lsc (AMPS) ORCOMPONENT(AMPS) MAX INV.OUTPUT CURRENT (AMPS) ORCOMPONENT(AMPS) ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSWIREANDCOND.CALCS.EQUIPMENT GROUNDGREEN OR BARE,OR GREEN/YELLOW UNGROUNDED CONDUCTOR(S). TYPICALLY POSITIVE ANY COLOR OTHER THAN GREEN OR WHITE/GRAY CONVENTION IS RED FOR GROUNDED SYSTEMS RED (+)AND BLACK (-)FOR UNGROUNDED SYSTEMS PV MODULE #1 DC/DC CONVERTER (1) CU 90 #12 AWG 30 11.36 1 1.25 1.25 17.75 ROOFTOP 35 >7/8"0 35 0.96 2 N/A 30 0.96 1.0 28.8 17.75 28.8 PV MODULE #2 DC/DC CONVERTER (1) CU 90 #12 AWG 30 11.39 1 1.25 1.25 17.8 ROOFTOP 35 >7/8"0 35 0.96 2 N/A 30 0.96 1.0 28.8 17.8 28.8 DC/DC CONVERTER JUNCTION BOX (1) CU 90 #10 AWG 40 15 1 1 1.25 18.75 ROOFTOP 35 >7/8"0 35 0.96 6 N/A 40 0.96 1.0 38.4 18.75 38.4 JUNCTION BOX INVERTER (1) CU 90 #10 AWG 40 15 1 1 1.25 18.75 ATTIC 35 IN ATTIC 0 35 0.96 6 0.80 40 0.96 0.80 30.72 18.75 30.72 47.0 0.94 0.94 0 0 N/A N/A N/A 0 0.94 40.0 40.0 47.0 61.1 1.0 1.0 0.94 0.94651.033535INT/EXT WALL40.032.0 INVERTER AC DISCONNECT (1) CU 75 #8 AWG 50 1.25 32.0 40.0 INT/EXT WALL 35 35 3 1.0 50 0.94 1.0 47.0 40.0 AC DISCONNECT PRODUCTION METER (1) CU 75 #8 AWG 50 1.25 32.0 40.0 INT/EXT WALL 35 N/A 0 35 0.94 3 1.0 50 0.94 1.0 47.0 40.0 47.0 PRODUCTION METER CIRCUIT BREAKER DISCONNECT (1) CU 75 #8 AWG 50 1.25 32.0 40.0 INT/EXT WALL 35 35 3 1.0 50 47.0 CIRCUIT BREAKER DISCONNECT EXISTING SERVICE PANEL (1) CU 75 #6 AWG 65 1.25 61.1 E-002WIRE COLOR CODING (2023) NEC SECTIONS 250.119 & 200.6 Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSTHREELINEDIAGRAMLEGENDEQUIPMENTTABLE QTY COMPONENT 1 PV MODULES #1 2 3 DC DISCONNECT 4 PV MODULES #2 5 JUNCTION BOX 6 RAPID SHUTDOWN 7 AC/DC INVERTER 8 AC/DC INVERTER W/INTE AC DISC 9 AC DISCONNECT (FUSIBLE) 10 11 PROD/GEN METER 12 SUB PANEL 13 14 15 EXISTING UTILITY METER TAG ELECTRICAL NOTES DC CONDUCTOR TAG AC CONDUCTOR TAG EQUIPMENT TAG AC# DC# GROUND CONDUCTOR TAGGND STRING MODULE QTY INVERTER# BACK-FEED SOLAR BREAKER: CONDUCTOR TABLE TAG QTY*SIZE TYPE DC1 DC2 DC3 DC4 DC5 AC1 AC2 AC3 AC4 AC5 GROUND SIZE TYPE CONDUIT TABLE AC6 AC7 AC8 AC9 AC10 DC6 DC7 DC8 16 AC DISCONNECT (INDEPENDENT) • *INCLUDES GROUND &CURRENT CARRYING CONDUCTORS 17 18 BATTERY NOTE:EQUIP TAGS MAY NOT BE IN SEQUENTIAL ORDER,N/A USEDSEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONS UNGROUNDED PV SYSTEMS:•INVERTERS,MODULES,AND DC COMPONENTS MUST BE LISTEDFORUSEINUNGROUNDEDSYSTEMS,TYPICALLYTRANSFORMER-LESS (TL) •OCPD'S WHERE NECESSARY MUST HAVE DISCONNECTING MEANS. •PV SOURCE CIRCUITS MUST BE EITHER PV WIRE,RATED ANDLISTEDFORWETLOCATIONSORJACKETEDMULTI-CONDUCTORCABLESINSTALLEDINRACEWAYANDRATEDPERAPPLICABLEVOLTAGE. •THE AC SIDE IS STILL GROUNDED ON THE NEUTRAL CONDUCTOR. •REQUIRE EQUIPMENT GROUNDING BUT DOES NOT HAVE SYSTEM GROUNDING;NO DC CURRENT-CARRYING CONDUCTOR ISCONNECTEDTOGROUND.THESE CONDUCTORS ARE COLORCODEDDIFFERENTLYTHANGROUNDEDPVSYSTEMS. AC/DC ELECTRICAL NOTES: •ALL OVERCURRENT PROTECTION DEVICES (OCPDs)MUST BERATEDFORTHEAPPLICABLEVOLTSONTHEDC/PV POWER SIDEOFTHEINVERTER. •EXTERIOR ENCLOSURES TO BE NEMA TYPE 3R OR BETTER. •ALL CONDUIT AND CONDUIT CONNECTIONS SHALL BE RATEDFORWETANDDAMPLOCATIONSWHENAPPLICABLE. INTERCONNECTION NOTES: •705.12(B)(4)CIRCUIT BREAKERS MUST BE SUITABLE FOR BACKFEEDING.NEC INFORMATIONAL NOTE:FUSED DISCONNECTS,UNLESS OTHERWISE MARKED,ARE SUITABLE FOR BACKFEEDING. •690.13(F)(2)DEVICES MARKED WITH "LINE” AND “LOAD” SHALL NOT BE PERMITTED FOR BACKFEED OR REVERSE CURRENT •705.12(B)(5)CIRCUIT BREAKERS BACK FEED FROM UTILITYINTERACTIVEINVERTERS(ANTI-ISLANDING,UL 1741 CERTIFIED) (+) (+) 2 2 DC(-) (-)DC 1 1 DC 1 DC DC (+) (+) 2 2 DC(-) (-)DC 1 1 DC1 DC DC 10 MODULES 9 MODULES DC3DC3 5 G G DC3DC4 G ACG N G L2 L1 3 6 DC INVERTER NAMEPLATE RATING 7600 W/240V MONITORING 7 EGC EGC #1 MODULE NAMEPLATE RATING 365W (+) (+) 2 2 DC(-) (-)DC 4 4 DC2 DC DC 9 MODULES #2 MOD ULE NAMEPLATE RATING 400W N G L2 L1 PV 11 N G L2 L1 AC2 9 L2 L1 L2 L1 GG NN READILY ACCESSIBLE OPEN BLADE AC SYSTEM DISCONNECT VISIBLE FROM APPROACH TO RESIDENCE 60A 240V LOCATED EXTERIOR ON WALL NEAR METER NEMA 3R AC1 L2 L1 L2 L1 GG NN 10 CIRCUIT BREAKER DISCONNECT EGC M 16 G N BUSRATING 15 MAIN C/BRATING GEC 200A 200A AC4AC3 MA SMART GENERATION METER BOTTOM LUGS TOSOLARGENERATION(LOAD)TOP LUGS TO UTILITY (LINE)LOCATED EXTERIOR NOTE: CONDUCTORS AC1, AC2, AC3 & AC4 MAY BE THWN-2 OR SER CABLE COMPLIES WITH NEC 240.21 OCPD RATING 40A 19 REC365NP2 Black 28 S440 Single-HD (240V) 1 INTEGRATED IN INV 9 REC400NP3 Black 3 Soladeck RSTC 0799-5B N/A INTEGRATED IN INV & OPT 1 SolarEdge SE7600H-US (240V) 0 1 10 Eaton DG222URB INV 1 70A BUS/MLO 2 9 INV 1 3 9 INV 1 1 1 1 0 1 1 120/240V - 1 N/A MA SMART GENERATION METER 2 #12 AWG PV Wire #6 AWG N/A Open Air 2 #12 AWG PV Wire #6 AWG N/A Open Air07#10 AWG PV Wire #6 AWG N/A Open Air 7 #10 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #6 AWG THWN-2 #8 AWG 1 inch EMT NO CENTER-FED MAIN BREAKER. PANEL CONFIGURED PER NEC 705.12(A)E-003DC/DC OPTIMIZER EXISTING MAIN SERVICE PANEL 200A BUS/200A MB 0 NOTE: ALL LINE SIDE PV CIRCUIT CONNECTIONS INVOLVING TAPS AND OR TRANSFORMERS SHALL INCORPORATE GROUNDING ELECTRODE CONDUCTORS (G-N BONDING) IN ALL LOCATIONS THAT ARE SEPARATELY DERIVED SYSTEMS AS REQUIRED BY CODE AND OR THE AHJ. GROUND BONDING JUMPERS (CONDUCTORS), TO CONNECT ANY APPLICABLE SEPARATELY DERIVED SYSTEMS SHALL BE FIELD VERIFIED BY QUALIFIED ELECTRICAL CONTRACTOR Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT ELECTRICALLAYOUTEQUIPMENT GROUNDING 1.METAL PV MODULE FRAMES MUST BE CONNECTED TO THE EGC (EQUIPMENT GROUNDING CONDUCTOR). 1.1.WEEBS MAY BE USED IN LIEU OF MODULE GROUND CLAMPSORLUGS,WITH APPROVAL OF AHJ AND RACKING MFG.WEEBS ARE ONE TIME USE ONLY.SEE "we-llc.com"FOR RACKING SPECIFIC WEEB,INSTALL INSTRUCTIONS,AND UL 2703 CERT. 1.2.FOR "LAY-IN"LUG MODULE GROUNDING;CORRECTHARDWAREOFPROPERMETALMATERIALTOAVOIDCORROSIONMUSTBEUSED.TYPICALLY DIRECT BURIAL RATED,TINNED,OR STAINLESS STEEL.GROUNDING LUGS MUST BEATTACHEDATMARKEDLOCATIONONEACHMODULE. 2.THE EGC (EQUIPMENT GROUNDING CONDUCTOR)IS USED TO BOND ALL NON-CURRENT CARRYING CONDUCTORS AND EXPOSEDMETALPARTSTHATMIGHTCOMEINTOCONTACTWITHCURRENT-CARRYING CONDUCTORS,INCLUDING THE FOLLOWING: 2.1.PV MODULES FRAMES,ARRAY MOUNTING RACKING;THEMETALCHASSISOFEQUIPMENTSUCHASINVERTERS,DISCONNECTS,METERS,JUNCTION BOXES AND COMBINERBOXES;AND METAL CONDUIT HOLDING CIRCUITS >250 VOLTSTOGROUNDPERNEC250.97 3.THE GEC (GROUNDING ELECTRODE CONDUCTOR)IS THECONDUCTORUSEDTOCONNECTTHEGEORGESYSTEM TO THESYSTEMGC,TO THE EGC,OR TO BOTH. 4.THE GE (GROUNDING ELECTRODE)IS A CONDUCTING OBJECT,OFTEN A ROD,RING,OR PLATE ESTABLISHING A DIRECTCONNECTIONTOEARTH.THE AC SYSTEM GROUND IS EXISTING, USUALLY AT THE EXISTING MAIN PANEL AND/OR UTILITY METER. THE GROUND CAN ONLY OCCUR IN ONE PLACE AND MUST NOT BEDUPLICATEDINSUB-PANELS OR ANYWHERE ELSE ON AC SIDE.RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSELECTRICAL SYMBOL LEGEND AC DISCONNECT PERFORMANCE METER UTILITY METER DC DISCONNECT DC COMBINER BOX AUTO TRANSFORMERCB DC AC ATF DCB P M DC DISCONNECTINGCOMBINERBOX SERVICE PANELSP SOLAR LOAD CENTER BATTERY SLC AC COMBINERACC BATT INV#DC/AC STRI NG INVERTER CLP CRITICAL LOADS PANEL XFMR TRANSFORMER JUNCTION BOXJB RSD RAPID SHUTDOWN SUB-PANELSUB ATS AUTO TRANSFER SWITCH TESLAGATEWAYTGW TESLAPOWERWALLTPW STS SMART TRANSFER SWITCH SECTION 1 PV ARRAY TAGSECTION#MODULE GROUP EMERGENCYBATTERYDISCONNECTEB RS EMERGENCYRSDSWITCH CBD ￿￿￿INV1ACSPMNORTH JB JB JB CBDPSCALE: 1/8” = 1’0” @ SHEET SIZE A3QTY 19 REC365NP2 Black MODULES QTY 9 REC400NP3 Black MODULES QTY 1 SolarEdge SE7600H-US (240V) INVERTER E-100PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER.Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT SHEET NOTES1SCALE: 1/2"=1'-0"CONDUIT,RACEWAY,J-BOX,AND PULL BOXES 2 3 5 6 7 SCALE: 1/4"=1'-0"8 9 4 1.PLACE ON CONDUIT AND/OR RACE WAYS EVERY 10'(60"),12" FROM BENDS,12"ABOVE AND BELOW PENETRATIONS. 2.CODE REFERENCE:NEC 690.31(G)(3) 3.MINIMUM OF 1 1/8"x 5 3/4" 4.FONT:3/8"AND .8 WIDTH FACTOR. 5.REFLECTIVE WHITE LETTERS ON A RED BACKGROUND. J-BOX,DC COMBINER,AND DC DISCONNECT SCALE: 1/4"=1'-0" NON-LOAD BREAK DC COMBINER /J-BOX 1.PLACED ON DC DISCONNECT(S)AND ON ANY EQUIPMENT THAT STAYS EN ERGIZED IN THE OFFPOSITION FROM THE PV SUPPLY. 2.CODE REFERENCE:NEC 690.13(B) 3.MINIMU M OF 3 1/2"x 10" 4.FONT:3/8" INVERTER(S) SCALE: 1/2"=1'-0" 1.A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATEDONORNOMORETHAN1M(3 FT)FROM THE SWITCH THATINCLUDESTHEFOLLOWING: 1. 2. MINIMUM OF 3 1/2"x 10 1/2" FONT:3/8" AC AND DC DISCONNECTS 1.PLACE ON ALL AC AND DC DISCONNECTS 2.CODE REFERENCE:NEC 690.13(B) 3.MINIMUM OF 1"x 10 1/2" 4.FONT:3/8" 5.WHITE LETTERS ON A RED BACKGROUND. SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" 1.CODE REFERENCE:NEC 690.13(C) 2.USE ON NON-LOAD BREAK RATED DISCONNECTION. 3.MINIMUM OF 1"x 6" 4.FONT:3/8"AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. DC DISCONNECTS 1. 2. VERIFY WHICH PLACARD IS REQUIRED WITH AHJ. 3. MINIMUM OF 1"x 4" FONT:3/8"AND .8 WIDTH FACTOR SWITCHBOARDS SCALE: 1/2"=1'-0" INVERTER # 1 1.USE PLACARD "INVERTER #1"WHEN MORE THAN 1INVERTER IS USED.NUMBER ACCORDING TO THREELINE DIAGRAM AND CALCULATIONS. 2.MINIMUM OF 1"x 4" 3.FONT:3/8" 4.WHITE LETTERS ON A RED BACKGROUND. USE PLACARD "[AC][DC]DISCONNECT #1"WHEN MORE THAN ONE DISCONNECT IS USED.NUMBER ACCORDING TOTHREE LINE DIAGRAM AND CALCULATIONS. SCALE: 1/4"=1'-0"MAIN SERVICE PANEL 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLE PLACARDS FOR THE SAME DEVICE.ALL INFORMATION FROM THE MULTIPLE PLACARDS MUST BE PRESENT. 2.BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED IN PLACE OF THE STANDARD WHITE LETTERS WITH REDBACKGROUND WITH AHJ APPROVAL. 3.ALL INTERIOR AND EXTERIOR DC CONDUIT,ENCLOSURES,RACEWAYS,CABLE ASSEMBLIES,JUNCTION BOXES,COMBINERBOXES AND DISCONNECTS ARE MARKED.(NEC 690.31[G],NEC690.13 &690.53) 4.THE MARKINGS ON THE CONDUITS,RACEWAYS AND CABLE ASSEMBLIES ARE EVERY 10 FEET,WITHIN ONE FOOT OF ALL TURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOWALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS ANDBARRIERS.(IFC 605.11.1.4,NEC 690.31[G][3]) 5.WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP,LAMINATEOR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOTCOVERED BY PV MODULES AN D ASSOCIATED EQUIPMENT,THELOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. 6.REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FORTHE ENVIRONMENT.MATERIALS USED FOR MARKING MUST BE WEATHER RESISTANT.UL STANDARD IS RECOMMENDED TO DETERMINE WEATHER RATING.UL LISTING OF MARKINGS ISNOTREQUIRED.SEE UL LABELING SYSTEM 969 (UL 969) 7.MARKING CONTENT AND FORMAT: 7.1.ARIAL OR SIMILAR FONT,NON-BOLD. 7.2.MINIMUM 3/8"LETTER HEIGHT FOR HEADERS. 7.3.MINIMUM 1/16"LETTER HEIGHT FOR DATA 7.4.CONTRASTING BACKGROUND AND LETTERIN G. 7.5.ALL CAPITAL LETTERS. 7.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 7.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE.MAY BE REDUCED AND /OR INCREASED TO UL APPROVEDMANUFACTURED PRODUCT CODE ABBREVIATIONS: NATIONAL ELECTRICAL CODE (NEC) INTERNATIONAL BUILDING CODE (IBC) INTERNATIONAL RESIDENTIAL CODE (IRC) INTERNATIONAL FIRE CODE (IFC) UNDERWRITERS LABORATORY (UL) DO NOT DISCONNECT UNDER LOAD RAPID SHUTDOWN SWITCH RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM THE LABEL SHALL BE REFLECTIVE WITH ALL LETTERS CAPITALIZEDANDHAVINGAMINIMUMHEIGHTOF9.5 MM (3⁄8 IN.),IN WHITE ON RED BACKGROUND. 2. 1/4"=1'-0" SCALE: 2CODE REFERENCE:NEC 690.56(C)(1)(a) 3TITLE:MIN.3/8"BLACKCHARACTERSONYELLOWBACKGROUND,REMAININGCHARACTERSMIN.3/16"INBLACKONWHITEBACKGROUND. 1LOC ATE NO MORE THAN 1 mFROMTHESERVICEDISCONNTMEANSTOWHICHTHEPVSYSTEMSARECONNECTEDANDSHALLINDICATETHELOCATIONOFALLIDENTIFIEDRAPIDSHUTDOWNSWITCHESIFNOTATTHESAMELOCATION. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE “OFF” POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRIC PV PANELS ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENGERGIZED IN THE OPEN POSITION ! THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT ! PHOTOVOLTAIC DC DISCONNECT PHOTOVOLTAIC AC DISCONNECT WARNING ARC FLASH HAZARD APPROPRIATE PPE REQUIREDFAILURE TO COMPLY CAN RESULT IN DEATH OR INJURY REFER TO NFPA 70E ! WARNINGWARNING 2017NEC11132021KN 5.WARNING LABEL IS WHITE AND ORANGE 3.WARNING LABEL IS WHITE AND ORANGE 4.WARNING LABEL IS WHITE AND ORANGE 5.DATA COLLECTED FROM AS-BUILT INFO,PRIOR TO PTO,BY OTHERS.RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSSTANDARDPLACARDS1.ONLY FOR UNGROUNDED SYSTEMS. 2.PLACED ON ALL ENCLOSURES WITH UNGROUNDED CIRCUITS OR DEVICES WHICH ARE ENERGIZED AND MAY BE EXPOSED DURING SERVICE. 3.MINIMUM OF 3"x 10 1/2" 4.FONT:3/8" ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENGERGIZED IN THEOPEN POSITION !WARNING DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES AREEXPOSED TO SUNLIGHT 5.WARNING LABEL IS WHITE AND ORANGE 10 11SCALE: 1/2"=1'-0"INVERTER(S) 1. 2. USE PLACARD "COMBINER #1"WHEN MORE THAN 1DC COMBINER IS USED.NUMBER ACCORDING TOTHREE LINE DIAGRAM AND CALCULATIONS. 3. MINIMUM OF 1"x 4" 4. FONT:3/8"AND .75 TO .8 WIDTH FACTOR WHITE LETTERS ON A RED BACKGROUND. DC COMBINER BOX SCALE: 1/2"=1'-0" ENGINEERING STAMP (if appl.)P-001QTY 19 REC365NP2 Black MODULES QTY 9 REC400NP3 Black MODULES QTY 1 SolarEdge SE7600H-US (240V) INVERTER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT 1.PLACARD PLACED AT ELECTRICAL SERVICE AND AT THE PVINVERTERANDPVDISCONNECTSIFNOTATTHESAMELOCATION. 2.MAP PLACARD PROVIDES A DIRECTORY OF THE SERVICEDISCONNECTINGMEANSANDPHOTOVOLTAICSYSTEMDISCONNECTIONMEANS. 3.CODE REFERENCE:NEC 690.56(A)(B),70 5.10 4.WHITE LETTERS ON A RED BACKGROUND. 5.MINIMUM OF 7 3/4"x 5" 6.FONT:3/4""CAUTION",1/4""WARNING",3/16"HEADER, 1/8"DATA AND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAIN SERVICEDISCONNECTINALOCATIONCLEARLYVISIBLEFROMWHERETHEDISCONNECTISOPERATED.(IFC 605.11.1.3) SHEET NOTES 1. 2. 3. 4. COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLEPLACARDS FOR THE SAME DEVICE.ALL INFORMATION FROMTHE MULTIPLE PLACARDS MUST BE PRESENT. BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED INPLACE OF THE STANDARD WHITE LETTERS WITH REDBACKGROUND WITH AHJ APPROVAL. ALL INTERIOR AND EXTERIOR DC CONDUIT,ENCLOSURES,RACEWAYS,CABLE ASSEMBLIES,JUNCTION BOXES,COMBINERBOXES AND DISCONNECTS ARE MARKED.(NEC 690.31[E][3],NEC 690.31[E][4]&690.53) REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FORTHE ENVIRONMENT.MATERIALS USED FOR MARKING MUST BEWEATHER RESISTANT.UL STANDARD IS RECOMMENDED TODETERMINE WEATHER RATING.UL LISTING OF MARKINGS IS NOT REQUIRED.SEE UL LABELING SYSTEM 969 (UL 969) 5.MARKING CONTENT AND FORMAT: 5.1.ARIAL OR SIMILAR FONT,NON-BOLD. 5.2.MINIMUM 3/8"LETTER HEIGHT FOR HEADERS. 5.3.MINIMUM 1/16"LETTER HEIGHT FOR DATA 5.4.CONTRASTING BACKGROUND AND LETTERING. 5.5.ALL CAPITAL LETTERS. 5.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 5.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE.MAY BE REDUCED AND /OR INCREASED TO UL APPROVED MANUFACTURED PRODUCT 6.ANSI Z535.4 PRODUCT SAFETY SIGN S AND LABELS:THIS INFORMATIONAL NOTE AND ITS REQUIREMENTS FORPLACARDSMAYBEUSEDWITHPRIORAPPROVALOFTHEAHJ.MOSTNOTABLEDIFFERENCESISCOLOROFPLACARDSANDUSEOFHANDWRITTENVALUESWITHINDUSTRIALMARKERSONSTANDARD PLACARDS WHERE THE VALUE MAY CHANGE AT AFUTURE DATE.I.E.ADDING MODULES AT A FUTURE DATE,OR STANDARD PLACARD MANUFACTURER INSTALLED ONELECTRICAL COMPONENT.AHJ APPROVAL REQUIRED.(SEENOTE #1 FOR INDIVIDUAL PLACARDS) 1 SCALE: 1/4"=1'-0"2 3 4 1.PLACARD PLACED ON EACH DISCONNECT,IF MORE THAN ONE PRESENT. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. SEE SHEET "E-001 /DC DISCONNECT [#]" 3.CODE REFERENCE:NEC 690.53 4.MINIMUM OF 2 1/2"x 8"OR 5"x 2 1/2"RESPECTIVELY. 5.FONT:3/8"HEADER,3/16"DATA 6.WHITE LETTERS ON A RED BACKGROUND. 7.IN SOME CASES TWO LABELS MAY BE REQUIRED.AN INVERTER WITHINTEGRATEDDCDISCONNECTUTILIZINGTWOMPPTTRACKERS;IF CONFIGURATIONUSESDIFFERENTMODULES. SCALE: 1/4"=1'-0" MAP PLACARD:MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION) SCALE: 1/4"=1'-0"UTILITY METER,SERVICE PANEL,SUB-PANELACDISCONNECT,AC SUB-PANEL MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE PV SYSTEM DC DISCONNECT ADC PHOTOVOLTAIC SYSTEM DC DISCONNECT MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDC 1.PLACARD PLACED ON EACH SOLAR SYSTEM DISCONNECTING COMPONENT. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. SEE SHEET "E-001 /AC DISCONNECT [#]" 3.CODE REFERENCE:NEC 690.54 4.MINIMUM OF 1 1/2"x 8 1/2"OR 1 3/4"x 6 1/2"RESPECTIVELY. 5.FONT:3/8"HEADER,3/16"DATA 6.WHITE LETTERS ON A RED BACKGROUND. RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS WARNING DUAL POWER SOURCES RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS 1.(#1)PLACARD PLACED AT MAIN UTILITY SERVICE DISCONNECT/BREAKER AND PV SYSTEM SUPPLY BREAKER AT POINT OF INTERCONNECTION.(#2 &#3)PLACARD(S) REQUIRED WITH #1 PLACARD WHEN UTILITY SERVICE AND PV SYSTEM DISCONNECT(S)ARE NOT LOCATED NEXT TO EACH OTHER.MAP PLACARD REQUIRED AS SPECIFIED. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. 2.1.VALUES WILL MATCH LOAD CENTER OR SUB-PANEL VALUES IF INSTALLED AFTER INVERTERS.IF AC CONNECTION TO SERVICE PANEL COMES FROM INVERTERS;SEE SHEET "E-001 /STRING INVERTER[#]SPECIFICATIONS". 2.1.1.INVERTERS ARE PARALLEL CONNECTIONS. 2.1.2."RATED AC OUTPUT CURRENT"WILL BE THE SUM OF THE INVERTERS 2.1.3."AC NORMAL OPERATING VOLTAGE"WILL BE THE NAME PLATE RATING OF THE INVERTER 3.CODE REFERENCE:NEC 690.54,NEC 705.12(B)(3) 4.MINIMUM OF 2"x 6 1/2"(#1),VARIES (#2 &#3) 5.FONT:3/8"HEADER,3/16"DATA (#1),1/4"(#2 &#3) 6.WHITE LETTERS ON A RED BACKGROUND. SCALE: 1/2"=1'-0"5 CAUTION WARNING ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAP PLACARD:MAIN SER VICE PANEL AND PV INVERTER (IF NOT SAME LOCATION)SCALE: 1/2"=1'-0" CAUTION 1.PLACARD PLACED AT ELECTRICAL SERVICE AND ATTHE PV INVERTER AND PV DISCONNECTS IF NOT ATTHESAMELOCATION. 2.MAP PLACARD PROVIDES A DIRECTORY OF THE SERVICE DISCONNECTING MEANS ANDPHOTOVOLTAIC SYSTEM DISCONNECTION MEANS. 3.CODE REFERENCE:NEC 690.56(A)(B),705.10 4.WHITE LETTERS ON A RED BACKGROUND. 5.MINIMUM OF 6 1/2"x 6 1/2" 6.FONT:3/4""CAUTION",1/4"HEADER,1/8"DATAAND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAINSERVICE DISCONNECT IN A LOCATION CLEARLYVISIBLE FROM WHERE THE DISCONNECT IS OPERATED.(IFC 605.11.1.3) DC DISCONNECTS &DISCO.COMBINER DYNAMICPLACARDS(WITH COMBINED WARNING PLACARD IF REQUIRED.EXAMPLE:LADWP) PV SYSTEM DC DISCONNECT PHOTOVOLTAIC SYSTEM DC DISCONNECT PV SYSTEM DC DISCONNECT PHOTOVOLTAIC SYSTEM DC DISCONNECT #1 #2 #3 RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING STRING INVERTER #1 - INTEGRATED AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS STRING INVERTER #2 - INTEGRATED AC DISCONNECT AC DISCONNECT #1 - INDEPENDENT/ SEPARATE AC SUB-PANEL #1 #1 #2 #3 CODE ABBREVIATIONS: NATIONAL ELECTRICAL CODE (NEC) INTERNATIONAL BUILDING CODE (IBC) INTERNATIONAL RESIDENTIAL CODE (IRC) INTERNATIONAL FIRE CODE (IFC) UNDERWRITERS LABORATORY (UL)VDC MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE ADC MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDCVDC MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE ADC MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDCVDC 1.PRIME CONTRACTOR /PERMIT APPLICANT SIGNERIS RESPONSIBLE FOR THE DESIGN ANDSPECIFICATIONS OF THE PHOTOVOLTAIC SYSTEM INSTALLATION.PRIME CONTRACTOR /PERMIT APPLICANT SIGNER WILL BE RESPONSIBLE FOR COLLECTION OF EXISTING ONSITE INFORMATIONREQUIREMENTS TO DESIGN,SPECIFY,AND INSTALLTHEEXTERIORMOUNTEDPORTIONOFTHE PHOTOVOLTAIC SYSTEM DETAILED IN THIS DOCUMENT. 2.ADVANCED SOLAR SOL UTIONS,INC ISRESPONSIBLEFORAPPLYINGSUPPLIEDINFORMATION INTO ASETOFPERMITDRAWINGS.ANY CHANGES TODRAWINGSARESUBJECTTOCONTRACTCONDITIONSBETWEENTHECLIENTANDADVANCEDSOLARSOLUTIONS,INC.INACCORDANCE WITH THE REQUIREMENTS OF THEAHJ. RESPONSIBILITY NOTES RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSRATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS N INVERTER W/ DC DISCO AC DISCO UTILITY METER &SERVICE PANEL N INVERTER W/ DC DISCO AC DISCO UTILITY METER &SERVICE PANEL SOLAR ARRAY ON ROOF TOP SOLAR ARRAY ON ROOF TOP PRODUCTION METER CIRCUIT BREAKER DISCONNECT PRODUCTION METER CIRCUIT BREAKER DISCONNECT 32.0240240 32.045.0 45.0 240480480 32.0 240 32.0 32.0 240 P-002SOLAR LOAD CENTER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT ELIGIBLE 370 wp Power PREMIUM FULL BLACK MONO N-TYPE SOLAR PANELS rec N-Peak 2 black Series MONO N-TYPE: THE MOST EFFICIENT C-SI TECHNOLOGY SUPER-STRONG FRAME UP TO 7000 PA SNOW LOAD FEATURING REC’S PIONEERING TWIN DESIGN FLEXIBLE INSTALLATION OPTIONS HIGH POWER FOR 25 YEARS NO LIGHT INDUCED DEGRADATION IEC 61215:2016, IEC 61730:2016, UL 61730 Pending ISO 14001:2004, ISO 9001:2015, OHSAS 18001:2007, IEC 62941 www.recgroup.com Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is commied to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. Ref: PM-DS1105Rev- A 02.21Specifications subject to change without notice.Ref: PM-DS1105Rev- A 07.21WARRANTY GENERAL DATA Cell type: 120 half-cut mono c-Si n-type cells 6 strings of 20 cells in series Glass: 0.13” (3.2 mm) solar glass with anti-reflection surface treatment Backsheet: Highly resistant polymeric construction (black) Frame: Anodized aluminum (black) Junction box: 3-part, 3 bypass diodes, IP68 rated in accordance with IEC 62790 Cable: 12 AWG (4 mm² PV wire, 43 + 47” (1.1 m + 1.2 m) in accordance with EN 50618 Connectors: Stäubli MC4 PVKBT4/KST4, 12 AWG(4 mm²) in accordance with IEC 62852 IP68 only when connected Origin: Made in Singapore LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS * MAXIMUM RATINGS MECHANICAL DATA Dimensions: 69.1 x 40.94 x 1.2 in 1755 x 1040 x 30 mm) Area: 19.70 sq 1.83 m²) Weight: 44.0 lbs (20.0 kg) Operational temperature: 40 ... +85°C Maximum system voltage: 1000 V Maximum test load (front): +7000 Pa (146 psf )* Maximum test load (rear): -4000 Pa (83.5 psf)* Max series fuse rating: 25 A Max reverse current: 25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 safety factor) ELECTRICAL DATA @ STC Product code*: RECxxxNP2 Black Nominal Power - PMAX (Wp) 355 360 365 370 Wa Class Sorting - (W)0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage - VMPP (V) 33.5 33.9 34.3 34.7 Nominal Power Current - IMPP (A) 10.60 10.62 10.65 10.68 Open Circuit Voltage - VOC (V) 40.7 40.8 40.9 41.1 Short Circuit Current - ISC (A) 11.27 11.31 11.36 11.41 Panel Efficiency (%) 19.4 19.7 20.0 20.3 Values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m², temperature 25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one wa class. * Where xxx indicates the nominal power class ( PMAX) at STC above. ELECTRICAL DATA @ NOCT Product code*: RECxxxNP2 Black Nominal Power - PMAX (Wp) 268 272 276 280 Nominal Power Voltage - VMPP (V) 31.3 31.7 32.1 32.5 Nominal Power Current - IMPP (A) 8.56 8.58 8.60 8.63 Open Circuit Voltage - VOC (V) 38.1 38.2 38.2 38.4 Short Circuit Current - ISC (A) 9.10 9.13 9.18 9.22 Nominal operating cell temperature (NOCT: air mass AM 1.5, irradiance 800 W/m², temperature 20°C, windspeed 1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. CERTIFICATIONS Nominal Operating Cell Temperature: 44.3 °C (±2°C) Temperature coefficient of PMAX: 0.34 %/°C Temperature coefficient of VOC: 0.26 %/°C Temperature coefficient of ISC: 0.04 %/°C *The temperature coefficients stated are linear values Rel. Efficiency (%)REC N-PEAK 2 BLACK SERIES 100 200 300 400 500 600 700 800 900 1000 85 90 95 100 105 Irradiance (W/m²) Typical low irradiance performance of module at STC. Measurements in mm [in] Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System size any ≤25 kW 25500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% See warranty documents for details. Some conditions apply. GR GRGR GR11±0.2 [0.43 ±0.1]6.6±0.2 [0.26 ±0.1]20.5±0.5 [0.8 ±0.02] GR 638 ±1 [25.1 ±0.04] 30 [1.2] 22.5 [0.9] 28 [1.1] 1755±2.5 [69.10 ±0.1] 845 [33.27] 156 [6.14] 156 [6.14] 455 [17.91]999 [39.33]1100 [43.3] 5.5±0.2 [0.22±0.01] 1200 [47.2]1040±2.5 [40.94 ±0.1]17 [0.7]45 [1.8] RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSPV MODULE #1 CUT SHEET R-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSRef: PM-DS1104Rev- A 07.22www.recgroup.com Specifications subject to change without notice.GRGR GR GR0.43±0.01 0.26±0.010.8±0.02 GR 0.24±0.01 74.8±0.1 33.8 20.5 39.3±0.11.247.2 47.2 0.9 27.9 ±0.12 1.1 40.9±0.10.7 1.8 Available from: Measurements in inches LOW LIGHT BEHAVIOUR Typical low irradiance performance of module at STC: Irradiance (W/m²)Rel. Efficiency (%)Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is commied to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. 85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 REC N-Peak 3 Black Series Product SPECIFICATIONS GENERAL DATA Cell type:132 half-cut mono c-Si n-type cells 6 strings of 22 cells in series Glass:0.13 in solar glass with anti-reflective surface treatment in accordance with EN 12150 Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) with silver support bars Junction box:3 -part, 3 bypass diodes, lead-free IP68 rated, in accordance with IEC 62790 Connectors:Stäubli MC4 PVKBT4/KST4 (4 mm²) in accordance with IEC 62852, IP68 only when connected Cable:12 AWG (4 mm² PV wire, 47.2+ 47.2 in in accordance with EN 50618 Dimensions:74.8 x 40.9 x 1.2 in (19.7 sq-) Weight:47.0 lbs Origin:Made in Singapore WARRANTY Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 989898 Annual Degradation 0.250.250.25 Power in Year 25 929292 See warranty documents for details. Conditions apply TEMPERATURE RATINGS* Nominal Module Operating Temperature:44.3°C (±2°C) Temperature coefficient of PMAX:0.34 /°C Temperature coefficient of VOC:0.26 /°C Temperature coefficient of ISC:0.04 /°C *The temperature coefficients stated are linear values CERTIFICATIONS PENDING IEC 61215:2016, IEC 61730:2016, UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance UL 61730 Fire Type Class 2 IEC 62782 Dynamic Mechanical Load IEC 612152:2016 Hailstone (1.37in) ISO 14001, ISO 9001, IEC 45001, IEC 62941 DELIVERY INFORMATION Panels per pallet:33 Panels per 40 GP/high cube container:792 24 pallets) Panels per 53 truck:TBD MAXIMUM RATINGS Operational temperature:40 ... +185°F Maximum system voltage:1000 V Maximum test load (front): + 7000 Pa (146 lbs/sq-)* Maximum test load (rear):- 4000 Pa (83.5 lbs/sq-)* Max series fuse rating:25 A Max reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 safety factor) STC NMOTELECTRICAL DATA Product Code*: RECxxxNP3 Black Power Output - PMAX (Wp) 390 400 Wa Class Sorting - (W)0/+10 0/+10 Nominal Power Voltage - VMPP (V) 36.8 37.6 Nominal Power Current - IMPP (A) 10.60 10.64 Open Circuit Voltage - VOC (V) 44.8 45.0 Short Circuit Current - ISC (A) 11.31 11.39 Panel Efficiency () 19.8 20.3 Power Output - PMAX (Wp)295 302 Nominal Power Voltage - VMPP (V) 34.4 35.2 Nominal Power Current - IMPP (A) 8.56 8.59 Open Circuit Voltage - VOC (V) 41.9 42.1 Short Circuit Current - ISC (A) 9.13 9.20 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one wa class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 /s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. wp Power ELIGIBLE PREMIUM FULL BLACK MONO N-TYPE SOLAR PANELS MONO N-TYPE: THE MOST EFFICIENT C-SI TECHNOLOGY SUPER-STRONG FRAME UP TO 7000 PA SNOW LOAD FEATURING REC’S PIONEERING TWIN DESIGN FLEXIBLE INSTALLATION OPTIONS NO LIGHT INDUCED DEGRADATION BIFACIAL CELLS CAN PRODUCE ENERGY FROM BOTH SIDES rec N-Peak 3 Black Series 400 PV MODULE #2 CUT SHEET R-101Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT 15756VRODUHGHFRP 2SWLPLHLVWDOODWLRLWDYHWHFROR Specicallydesignedtoworkwith poweroptimizers Built-inmodule-levelmonitoring Outdoorandindoorinstallation Optional:Revenuegradedata,ANSIC12.20 Class0.5(0.5%accuracy) Record-breakingeciency Fixedvoltageinverterforlongerstrings Integratedarcfaultprotectionandrapidshutdownfor NEC2014and2017,perarticle690.11and690.12 Extremelysmall UL1741SAcertied,forCPUCRule21grid compliance 6LOH3DVHYHUWHULWDYH7HFROR IRU1RUWPHULFD SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ SE7600H-US/SE10000H-US/SE11400H-US 55517 686 686 686 686 686 686 686 287387 5DWHG3RZHU2XWSXW#9#9 #9#9 #9#9 9 0DLPXP3RZHU2XWSXW#9#9 #9#9 #9#9 9 2XWSXW9ROWDH0L1RP0Dü ü ü ü ü ü ü 9DF 2XWSXW9ROWDH0L1RP0Dü ü ü 9DF )UHTXHF1RPLDO+ 0DLPXPRWLXRXV2XWSXWXUUHW#9 0DLPXPRWLXRXV2XWSXWXUUHW#9 ),7UHVROG 8WLOLW0RLWRUL,VODGLProtection,CountryCongurable7UHVROGV <HV 1387 0DLPXP3RZHU#9 : 0DLPXP3RZHU#9 : 7UDVIRUPHUOHVV8URXGHG<HV 0DLPXP,SXW9ROWDH 9GF 1RPLDO,SXW9ROWDH 9GF 0DLPXP,SXWXUUHW#9GF 0DLPXP,SXWXUUHW#9GF 0D,SXW6RUWLUFXLWXUUHW GF 5HYHUVH3RODULW3URWHFWLR<HV URXG)DXOW,VRODWLRHWHFWLRN 6HVLWLYLW MaximumInverterEciency CECWeightedEciency #9#9 1LWWLPH3RZHURVXPSWLR: 7217856 6XSSRUWHGRPPXLFDWLR,WHUIDFHV 56(WHUHWL%HHRSWLRDOHOOXODURSWLRDO 5HYHXHUDGHDWD16,2SWLRDO 5DSLG6XWGRZ1(DGXWRPDWLF5DSLG6XWGRZXSRULGLVFRHFW 67152031 6DIHW8/8/68/%6DDGLD),DFFRUGLWR7,/0 ULGRHFWLR6WDGDUGV ,(((5XOH5XOH+, (PLVVLRV )3DUWODVV% 167721637216 2XWSXWRGXLW6LH:5DH PLLPXP:PLLPXP: ,SXWRGXLW6LHRI6WULV:5DH 3/4”minimum/1-2rings/14-6AWG 3/4”minimum/1-3rings/14-6AWG LPHVLRVZLW6DIHW6ZLWF+:LPP :HLWZLW6DIHW6ZLWFlb/kg 1RLVHG% RROL1DWXUDORYHFWLR 2SHUDWL7HPSHUDWXUH5DHWRWR(-40˚F/-40˚Coption)˚F/˚C 3URWHFWLR5DWL1(0,YHUWHUZLW6DIHW6ZLWF )RURWHUUHLRDOVHWWLVSOHDVHFRWDFW6RODU(GHVXSSRUWAhighercurrentsourcemaybeused;theinverterwilllimititsinputcurrenttothevaluesated5HYHXHUDGHLYHUWHU316(+8611)RUSRZHUGHUDWLLIRUPDWLRUHIHUWRhttps://www.solaredge.com/sites/default/les/se-temperature-derating-note-na.pdf YHUVLR316(+86118 6LOH3DVHYHUWHULWDYH7HFRORIRU1RUWPHULFD SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ SE7600H-US/SE10000H-US/SE11400H-US ©SolarEdgeTechnologies,Inc.Allrightsreserved.SOLAREDGE,theSolarEdgelogo,OPTIMIZEDBYSOLAREDGEaretrademarksorregisteredtrademarksofSolarEdgeTechnologies,Inc.Allothertrademarksmentionedhereinaretrademarksoftheirrespectiveowners.Date:12/2018/V01/ENGNAM.Subjecttochangewithoutnotice.RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSINVERTER CUT SHEET R-102Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT RZHU 2SWLPLHU 4 487 87 5DWH,SW3RHU4: EVROWH0DLPP,SW9ROWDH9RF9F 03372SHUDWL5DH9F 0DLPP6RUWLUFLWUUHW,VFRIRHFWH390ROHF 0DLPP(IILFLHF :HLWH(IILFLHF 2YHUYROWDHDWHRU,, 28787852(572 0DLPP2WSWUUHWF 0DLPP2WSW9ROWDH9F 287878572(5270(52(7()520(57(525(57(52)) 6DIHW2WSW9ROWDHSHU3RHU2SWLPLHU9F7520/( (0)3DUWODVV%,(,(,CISPR11,EN-55011 6DIHW,(FODVV,,VDIHW8/ 0DWHULDO8/9895HVLVWDW 5R+6HV )LUH6DIHW9(5( 7//72()72 0DLPPOORH6VWHP9ROWDH9F LPHVLRV:/+PP :HLWLFOLFDEOHVUOE ,SWRHFWRU0 ,SW:LUH/HWP 2WSWRHFWRU0 2WSW:LUH/HWP 2SHUDWL7HPSHUDWUH5DHWR˚C 3URWHFWLR5DWL,31(03 5HODWLYH+PLLW 5DWHSRHURIWHPROHDW67LOORWHFHHWHSRHURSWLPLHU5DWH,SW3RHU0ROHVLWSWRSRHUWROHUDFHDUHDOORH)RURWHUFRHFWRUWSHVSOHDVHFRWDFW6RODU(H)RUDPELHWWHPSHUDWUHDERYH)SRHUHUDWLLVDSSOLH5HIHUWR3RHU2SWLPLHUV7HPSHUDWUHH5DWL7HFLFDO1RWHIRUPRUHHWDLOV VWHPHVL8VLDRODU(GHYHUWHULOHDVHDYHLOHDVH7UHHDVH7UHHDVHIRUULG 0LLPP6WUL/HW3RHU2SWLPLHUV646 0DLPP6WUL/HW3RHU2SWLPLHUV 0DLPP1RPLDO3RHUSHU6WUL: 3DUDOOHO6WULVRILIIHUHW/HWVRU2ULHWDWLRVHV ,IWHLYHUWHUVUDWHSRHU≤PDLPPRPLDOSRHUSHUVWULWHWHPDLPPSRHUSHUVWULLOOEHDEOHWRUHDFSWRWHLYHUWHUVPDLPPLSWSRHU5HIHUWRWWSVVRODUHHFRPVLWHVHIDOWILOHVVHSRHURSWLPLHUVLOHVWULHVLDSSOLFDWLRRWHSI)RUWH9ULLWLVDOORHWRLVWDOOSWR:SHUVWULHWHPDLPPSRHULIIHUHFHEHWHHHDFVWULLV:)RUWH9ULLWLVDOORHWRLVWDOOSWR:SHUVWULHWHPDLPPSRHULIIHUHFHEHWHHHDFVWULLV:,WLVRWDOORHWRPL6VHULHVD3VHULHVSRHURSWLPLHUVLHLVWDOODWLRV ROD(GFRORLV,FOOLVVYG2/5(*(ROD(GORR2,0,(%2/5(*(DDGPDNVRLVGDGPDNVRIROD(GFRORLV,FOORDGPDNVPLRGLDDGPDNVRILVSFLYRZVD60ENG-NLEMFRFDZLRRLFRELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSDC/DC CONVERTERS CUT SHEET R-103Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT LU5DFNLQ6WP YLUOLZL OOFRPSRQQWKDEQDODWG IRUSULRUWUFWUDOSUIRUPDQF PECertied 3UWDPSGQLQULQOWWUDU DDLODEORQOLQIRUPRWWDW SHZZ-PYLHPU Certiedtomaintainthereresistance UDWLQRIWKLWLQURRIWUFWU LZPUZZPZHU URQOLQRIWDUPDNLWLPSO WRFUDWKDUDQGSULFSURMFW 33PZLZLT QWLUWPDQGFRPSRQQWPW WKODWWIIFWL/WDQGDUG LHYHYYHU 3URGFWDUDUDQWGWRDUUL LWKRWDQLPSDLULQGIFW YLHOLLHZPOHLSLYHLPUZHSSHPVUZ 7KLUUDFNLQWPKDEQFDUIOOFUDIWGWRWUDPOLQUSDUWRIWKLQWDOODWLRQSURFWDNLQ RWDOORIWKWLURPKDORWKDWRWRIIWKURRIDQGRQWRRUQWSURMFWIDWUWKDQU LUretainsthestrengthandreliabilitythatIronRidgeinstallershavecometodependon.Whetheryou’rea DRQGLQWDOOULWKDUQGURUEOWRUMWWWLQWDUWGLQRODUEUDWKDLWKRSQLU HHZOLL 0YVUPL0USSYPOZYLZLYL7HLUZ7LUPULYZPVU HPSZ LZZVYPLZ HHZOLL LZPUZZPZHU 4LFNORIURPURKODRW WRIOOQLQUGWP .VV0YVUPLVTLZPU LZVYLZ PYLHPS 7KWRKURSQLU UDLOIRUKLKUORDGFDSDFLW 8’spanningcapability LUPDQDPQWWUD 0LOORUDQRGLGEODFN PYLVR RQQFWLU5DLOWR DWWDFKPQWLWKD OLFNRQOLGDLO URSLQWRRSQORW QRGLGDPEO PYLHPS 7KOLKWURSQLU UDLOIRUWDQGDUGFRQGLWLRQ 6’spanningcapability LUPDQDPQWWUD 0LOORUDQRGLGEODFN PYLHPSPLZ 6WUFWUDOOFRQQFWDQG ERQGLU5DLOWRWKU 5LQWDOODEOSWR ,QWUQDOSOLFGLQ 1RPRUSOLFUO PYLHWZ ORFNQWUDQGSURLGD nishedlooktoAire™Rails. 6WDFURQUDLOQG 6PPWULFDOLWKGUDLQ RUURKFWQG 6FUOERQG0/3DQG DFFRULWRLU5DLO ORIULQGOLQWDOODWLRQ •Laysushinrailchannel •Lowproleformfactor PYL37,VU SHTWZ.YVUPU PYL3VRPZ 6FUOERQGEWQ PRGOWRLU5DLO LWPPPRGO WLOL2GLQ 0LQLPDODS PYL3VR,UZ 6FUOERQGPRGOWR LU5DLODORQQG LWPPPRGO DUDLOQDPQW ODQDWKWLF PYL3VRLHSO 6FUOERQGPRGOWR UDLOQGQWLUOKLGGQ QOGIRUDLQWDOO 5REWWWKUODK LWPRWPRGO WWYVLMVY-3/YYPHULAVULZ LUKDORULGD3URGFWSSURDO GGLWLRQDOGWDLOFDQEIRQGRQWK ORULGDLOGLQRGELW 3LHYUVYLHbit.ly/orida-aire WWDFKUDLOWRWLOURRI LWKLURFNLQFOGG •Worksonat,S,&Wtiles 6LQORFNWLQWDOODWLRQ •Optionaldeckashing PYLSSPSL/VVR .SLULQFRQWDLQGLQ RSQLU5DLOFKDQQO 1RPRGOLQWUIUQF 6LPSOSULQGLQ 6ORWIRUDUPRDO PYLSPW PYL3 RQGLU5DLOWR URQGLQFRQGFWRU •Simpliedwithsinglebolt •Low-proleformfactor RUNLWK ULVVSZLT/L/LHVTWVULUZ RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSRACKING & RAIL CUT SHEET R-104Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT ,, 2 1 2 1.07 1.26 8.00 1.00 4.00 5/16-18UNC-2A 0.24 0.32 5/16-18UNC-2A 0.68 1/2"DriveHead 1) AireTie,A1 2) AireSplcBolt,Hex ITEMNO DESCRIPTION QTYINKIT 1 AireTie,A1 1 2 AireSplcBolt,Hex 2 PartNumber Description AE-A1TIE-01-M1 AIRETIE,A1(BONDEDSPLICE) Property Value Material 300SeriesStainlessSteel Finish Clear Property Value Material 6000SeriesAluminum Finish Mill RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSRACKING & RAIL CUT SHEET R-105Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSSTANCHION - ROOF ATTACHMENT CUT SHEET R-106Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSSTANCHION - ROOF ATTACHMENT CUT SHEET R-107Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT pe.eaton.com General Duty Non-Fusible Safety Switch DG222URB UPC:782113144238 Dimensions: Height: 7.5 IN Length: 6.41 IN Width: 8.4 IN Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: Type: General Duty/Non-Fusible Amperage Rating: 60A Enclosure: NEMA 3R Enclosure Material: Painted galvanized steel Fuse Configuration: Non-fusible Number Of Poles: Two-pole Number Of Wires: Two-wire Product Category: General Duty Safety Switch Voltage Rating: 240V Supporting documents: Eatons Volume 2-Commercial Distribution Eaton Specification Sheet - DG222URB Certifications: UL Listed Product compliance: No Data______________________________________________________________________ © 2016 Eaton. All rights reserved. V2-T1-26 Volume 2—Commercial Distribution CA08100003E—May 2018 www.eaton.com 1 1.1 Switching Devices Safety Switches All general-duty switches above 100A and all heavy- duty switches incorporate these K-Series switch design features. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not provided on general- duty switches, but available as a field kit or factory installed Clear Line Shield Clearly Visible Handle ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Triple Padlocking Capability ●Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Additional Locking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Interlocking Mechanism ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Tangential Knockouts ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Bolt-On Hub Kits ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Standards and Certifications ●UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Seismic Qualifications ●General-duty switches exceed the requirements of Uniform Building Code (UBC) and California Code Title 24 OSP-0011-10, OSP-0012-10 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSAC DISCONNECT CUT SHEET R-108Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884410.535Conz, Mark42 Park Hill RdNorthampton, MA 0106202/08/2023SUBMIT FOR PERMIT