22B-035 BP-2023-0248 18 CORTICELLI ST COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 22B-035-001 CITY OF NORTHAMPTON Permit: New Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit # BP-2023-0248 PERMISSION IS HEREBY GRANTED TO: Project# 2023 NEW SFH Contractor: License: Est. Cost: 475000 NU-WAY HOMES INC 013693 Const.Class: Exp.Date: 07/20/2023 Use Group: Owner: INC NU-WAY HOME, Lot Size (sq.ft.) Zoning: URB/WP Applicant: NU-WAY HOMES INC Applicant Address Phone: Insurance: 10 WHITE AVE (413)563-0085 EAST LONGMEADOW, MA 01028 ISSUED ON: 03/03/2023 TO PERFORM THE FOLLOWING WORK: BUILD NEW SINGLE FAMILY HOUSE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fees Paid: $1,076.10 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner The Commonwealth of Massachu tts I v Board of Building Regulations and Standar FOR Massachusetts State Building Code, 780 CMR MAR — 1 9t12? MUNICIPALITY USE Building Permit Application To Construct,Repair, Renovate Qr Dnolish.a--- Revised Mar 2011 One- or Two-Family Dwelling `''''' '`''.' This Sect,*For Official Use Only Building Permit Number: —oZ 3 -.7ci6 Date Applied: 119460A.., ' `, t,3_,.1 Building Official(Print Name) SignatureI / ---� D�fte SECTION 1: SITE INFORMATION 1.74oRerty Address: 1.2 Assessors Map&Parcel Numbers 1.1 a Is this an accepted street?yes X no Map Number Parcel Number 1.3 Zonin Information: 1.4 Property Dimensions: i Ur2r5 Nei_A), Si�Ar , : 6076 3/ Zoning District Proposed Use J.,/... Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard -- Required Provided Required Provided Required Provided - /O ' /7. i6,. "'/E ,;i.o ' /la 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Info' ation: 1.8 Sewage Disposal System: Public Private❑ Zone: _ Outside Flood Zone? M 'cipaX On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 1 2.1 Owner'of Record: ,, NU -1,01 l� f.5XmC, Ei /� t�daude ` 4114- 0/O g Name(Print) City,Sta ZIP JO Cc.)1:1/r /'(Ue. CSC/'5I 5.i3-"COES— !1,0 iv i4 j//76.44e5 0 @ (r.^;74//, (40_,� No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Constructional. Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units Other 0 Specify: Brief Description of Proposed Work': 6 rbLila A. ,ije,J-- f ,r'e , -r `7/1 is Loc. T(rz7 i{-ri'ri IZ,4z/ y `'/'e -- exiS7- -��,i- a/ASe . SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1. Building $ I/50i -- 1. Building Permit Fee: $ Indicate how fee is determined: 2.Electrical $ 7 0 Standard City/Town Application Fee U� 0 Total Project Costa (Item 6)x multiplier x 3. Plumbing $ 9.5�0O0 -' 2. Other Fees: $ 4.Mechanical (HVAC) $ ;,',1„5;POO List: 5. Mechanical (Fire $ Total All Fees: .to- Suppression) Check No.it 3 Check Amour . 11O Cash Amount: 6. Total Project Cost: $ /7$` 0 Paid in Full 0 Outstanding Balance Due: City of Northampton Massachusetts < , 1, DEPARTMENT OF BUILDING INSPECTIONS % 212 Main Street • Municipal Building vb•., ='Db r y,, Northampton, MA 01060 SbjY•• N CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40, S54, a condition of Building Permit Number //CO cc//% S% is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A. The debris will be disposed of in: Location of Facility: 1) S 14 (4//i.,r) d The debris will be transported by: Name of Hauler: U S 14 ) i51W//%'� Signature of Applicant: �-% Date: ...2 / 401;2.i SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS -0/36 7 � ao� 3 ' 11h N 04. 1, 4„q fire / License Number E iratio Date Name of CSL Holder /0 r �� � ve List CSL Type(see below) (/ iq No.and Streeet / T e Description 14 Si"- L(Ph elf,",/vim Q'0 F U Unrestricted(Buildings up to 35,000 cu.ft.) Ci /Town,State,ZIP s` R Restricted 1&2 Family Dwelling M Masonry RC Roofing Covering '_4' WS Window and Siding r SF Solid Fuel Burning Appliances 6 --o0 111 U eu 4-4 J r$4o E. (-r"w f I Insulation Telephone Email address . ('r,7 D Demolition 5.2 Registered Home Improvement Contractor(HIC) '— �//ad 2� 03 '"' /7r1 Mv`Q z HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name Utt)rq-j1-720-A7e_c 0 43ff371/112 N and Street 7 3 J c Email address (-6 / 77 City/Town, State,ZIP Telephone SECTION 6:WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes LY,__ No .❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize to act on my behalf,in all matters relative to work authorized by this building permit application. Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury th all of a information contained in this application is true and accurate to the best of my knowledge and un s ' g. • M ' -vie c1-ntiS 1�c� 3'0 ice' /41'1 /z3/.2 3 Print Owner's Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq. ft.) /7V9 Habitable room count Number of fireplaces / Number of bedrooms y Number of bathrooms ? Number of half/baths / Type of heating system elecr{2 iL f/� Number of decks/porches / Type of cooling system C pa,yy,/v/ 44.0 Enclosed Open i 3. "Total Project Square Footage"may be substituted for"Total Project Cost" 1 � Cor-t�uc,fLs : The Commonwealth ofMassachusetts 11. ` — .1 Deportment of Industrial Accidents L =:. dam c im= , 1 Congress Street,Suite 100 • '�?�= MABoston, M 02114-201 :,.—set N'ww mass.grovfdio 11 takers'Compensation Insurance Affidavit:Buildersi("ontractorsrElectriciansfPlumbers. TO BE FILED WITH"IDE PERMI'ii i t A11 l IIORI"l:i. Applicant Information Please Print Le¢ibly Name IHusmcssOrganivatiom'individual): /1)4,) •— &) V'f t" . . ice/-. Address: 10 t 2 A,'T 14 tie E/ - e ,v1 O� City/State/Zip: 9 S�(, (4i a&G Phone##: (YY 3)S'_` t2 ) Are yea an employer?Cheek the apprupriateC at: Type of,project(required): 1.0 I am a employer with engrky.ts(full anu'ur part-omit.• ']. construction 20 I am a.uk pruprietcr or partnership and hate nu employee%aurking fur me in g. 0 Remodeling; u any capacity-[No workers'. np.insurance nquircad.I 9. ❑Demolition 30 I am a humtvvrner doing all stork myself.(No in orkcts'comp.insurance ncluireal.l' 4.0 I am a humoun net and will he hiring snetraciurs to conduct all work on my property. I will 10 0 Building addition ensure that all contractors either has workers'cumperosalrun insurance to air sole 1 1.❑Electrical repairs or idditt1 in% proprietors frith no employees. 12.❑Plumbing repairs or addition% 5{=I I am a general contractor and I hate hind the subcontractors listed on the attached shell. 13�Root repairs Thu ••subcontractors have employee%and base workers'comp.insurance.• 4_❑Other e -oipxatrun and its officer%have exercised their right of exemption per WiL c. - 15_'.§It 41.and we hate no employees.[Nu workers'comp.insurance require&J •Any applicant that checks box n1 must also fill out the section hrluw showing their workers'eumpensation pokey information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside cwrniraciors count submri a new aflulat it niche-ailing!smell. 1C'ontracWn that check this box must attached an additional short tbov ing the name of the wlM-cartlrators and state w heiher or not those entities hate employees. If the sah-curitracturs hate employees.they must pros ide their ttorkcrs"comp.polity rnimnk.r. 1 am an employer that is providing rtoriters'compensation insurance for my employees. Below is the policy and Job site information. Insurance Company Name: Policy#or Self-ins.Lic.#: Expiration Date: Job Site Address: City State:'Zip: Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152.*25A is a criminal violation punishable by a fine up to S1,500.00 anillor one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a tine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance cok'erat;e verification. I do hereby ertify the pains and 1,4 alties of pe rj )'that the in frrrmativn provided abate is true and correct. Signature: ),'f � /, Date: Z 3,�-r5.. 3' Phone (' '3) 7!t —or?8 r Official use tin!;,. Do not write in this area,to be completed by city or town official ( ity or I v,tt tt: Permit/License# Issuing„authority (circle one): 1. Board of Health 2. Building Department 3.(•it ?fawn Clerk 4.Electrical Inspector 5. Plumbing Inspector tic Oilier ( onlact Person: Phone#: A�IJ CERTIFICATE OF LIABILITY INSURANCE DATE(YIIIDD/YYYY) 07/28/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES I BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the poltcy(ies)must have ADDITIONAL INSURED provisions or be endorsed. if SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). I PRODUCER t CONTACT Paula Belisle NAME: Crimmins-Graveino Insurance PHOONE Na.Ertt: (413)283-8378 A1C,No): (413)283-2556 (AF1382 Main Street Ennr ksB: phetlsle@cgina.com P.O.Box 905 IN SURER(8)AFFORDING COVERAGE NAM a Palmer MA 01069 e16UREAA: dames River insurance Company 12203 INSURED INSURER B Nu-Way Homes Inc INSURER C: 10 White Avenue INSURER D: INSURER E: East Longmeadow MA 01028 pig F: COVERAGES CERTIFICATE NUMBER: 2022 GL REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDMON OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WENCH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCEAFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.UMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. �6RI i a1NYn POLICY NUMBER POLICY EiF POLICY DP 111t�LTR!!! TYPEORINSURANCE SVIVOQnryyr) ,{MN1DOANVT) X COMMERCIAL GENERAl.LIABILITY EACH OCCURRENCE f 1,000,000 CAI S-MADE 21 OCCUR DAMAGE 70RENTED PREMISES(Ea RENTED ce) $ 100'040 NM EXP(Any ore parson) S 5,000 A _ 000840844 0810612022 08108/2023 PERSONAL&ADVINJURY $ 1,00(3,000 GENLAGGREGATELMAITAPPUESPER GENERAL AGGREGATE $ 2,000,000 POLICY ElT Ej WC PRODUCTS-COMP/OP AGfl ^.IQ 2.000,000 OTHErt $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ — IEn occident) ANYAUTO B0DLY INJURY(Per person) $1 AUTOS SCHEDULED BODLYINJURY IPereaident $ HIRED NON-OWNED ; ONLY AUTOS PROPERTY DAMAGE —AUTOS ONLY AUTOS ONLY IPer eeddent) $ UMBRELLA LAB— — OCCUR EACH OCCURRENCE $ EXCESS LAB CLAIMS MADE • AGGREGATE $ DED RETENTION S $' WORKERS COMPENSATION I PER 0TH- AND EMPLOYERS'LIABILITY YIN j STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTNE ❑ NIA E.L.EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? Mandatory In NH} EL.DISEASE-EA EMPLOYEE 3 pee,Read _ DIf PTION OF ONOFer EL DISEASE-POLICY LI ITT S DESCRI OPC-RATIONS below DESCRIPTION OP OPERATIONS/LOCATIONS I VEHICLES(ACORD 1St,Addltlon d Ramada Schedule,maybe attaehad If ma=epees II required) RE: 18 Corticetll St Florence,MA 01062 CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE MOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN CIty of Northampton ACCORDANCE WITH THE POLICY PROVISIONS. Building Department 212 Main Street AUTHORIZE) EP REPRESENTATIVE Northampton MA 01060 "die �girt"' I I m 1988.2015 ACORD CORPORATION. All rights reserved. ACORD 25(2018103) The ACORD name and logo are registered marks of ACORD 1 DDER Massachusetts Home Energy Scorecard Home Energy Use Wlaasuhuactts I)cpartnIcnr 0 Euerg)RA.,.vtr.e, This scorecard compares the home's energy use and carbon footprint to an average home in Massachusetts. 0482_John Handzel_18 Corticelli Home Energy Use Home Carbon Footprint St_Northampton_250216 .rib. :-...ow:tr.t :stimatt d total energy u.;e(e' ctricity This shows the estimated annual carbon emissions 0 c°rt'Lt;`I - and ncati„g fuel)of your t,om,for one year The .ower associated with your home and is based on your home s 0482_John Handzel_18 Cortcelil the t n-rgy us : the beta r estimated total annual energy use. i he lower the score. St_Northampton_230202 the less carbon pollution is released into the atmosphere. Yew dui': Sq. •=ootai;e 2023 2,688ft2 mmBtu,y_ tort/yr Number o Bedrooms Primary hea::ng Fuei Worse 4^dolse 3 electr.c A- -essment L. Energy Speciali•t 300 25 t ebr,:ar, 6. 2023 FTuI DellaTu e Yearly Energy Use Electric 141,927 wtih Yearly Energy Co ts* 52,171 125.0 9.7 IIII Heating41111, Avg. home in MA Avg. home Lights &Appliances in MA p II Hot Water 51 Service Charges �— 3.2 II Cooling 0 0 Electric: $0.14/kWh better Better 'These are estimated costs.Actual energy costs may vary and_are based on many factors such asoccupant behavior, weather and utility rates. Please see the next page for more information on ha. the Home L nergy Use and Home Carbon Footprint are calculated. 18 Corticelli St, Northamton, MA 01062 Brought to you by ilb February 16, 2023 I 4.0.2.3098 ekotrope DDER More Information Massarhusctts Ihpartmc"r 7[urns Rxwurn, Your Massachusetts Home Energy Scorecard The Massachusetts Home Energy Scorecard tMA Scorecard)is a tool to assess a home's expected energy use, cost, and carbon footprint.A low energy use generally means that a home has a smaller carbon footprint and lower energy costs.The MA Scorecard also allows for comparisons of one home's energy use and carbon footprint. This is because the energy use and carbon footprint are calculated without the influence of occupant behavior,which can vary. Home Energy Use The Home Energy Use(HEU)calculation is based on a home's size,design, insulation levels, air leakage, heating and cooling systems, major appliances, lighting, hot water heating, and any electricity produced by on-site solar PV.The HEU number is Home Feature Summary "normalized" in the sense that occupant behavior,which can vary, is taken out of the calculation.A home's actual energy use will vary with number of occupants,occupant Home Type. Single fam.1/ ie ached behavior,weather, and changes to the home. "1odel .,chn'lanozel to-,om mmini:y: i.oi hamron Condiduned FloorA.ea: 2,688 ttl Number of Bedrooms: s Useful Terminology rrimar' Hea:'ng 0,'tem: Au Source Heat Pump•tlectac 8 HSPF Stu Primary Cooling System: An Source Heat Pump•tlectrc• 14 Sc ER A Btu,or British Thermal Unit, is a measurement of the heat/energy content of fuel. Primary Water Heating: Residential Water Heater•Electric•3.88 mmBtu stands for one million Btus. One Btu the energy produced by a single wooden Energy Factor match.One million Btus.the energy produced by 7 gallons of gasoline used in a typical House Tiyhtness: 3 ACH50 car. Ventilation: t-0 CFM •54 Watts Duct Leakage to Outside: 1 i CFM @ 25Pa 0141 / 100 ft-) Carbon Footprint Above Grade Walls R-23 The greenhouse gas emissions associated with a home's energy use impact the Ceiling: Attic, R 60 environment. The Carbon Footprint calculation is based on the carbon emissions for the Window Type: U-Value. 0.28, SHGC: 0.34 annual amounts,types, and sources of fuels used in your home. Measurement is in tons Foundation Walls R 23 of carbon dioxide per year(tons/year).One ton =2,000 miles driven by one car(typical Framed Floor: N/A 2 mpg car.). For electricity, carbon emissions are based on electricity consumed onsite and the mix of fuel sources used in the region to generate that electricity at the time of this report. For fossil fuel used in heating and hot water,carbon emissions are based on the therms of natural gas or gallons of oil or propane used in the home. Average Home in Your Area The"Average Home in Your Area"refers to the average energy use or carbon footprint of all the homes in Massachusetts before implementation of any energy improvements. The average may vary slightly over time as homes become more efficient due to improvements. 18 Corticelli St, Northamton, MA 01062 Brought to you by 1� a kot ro pe February 16,2023 I 4.0.2.3098 Home Energy Rating Certificate Rating Date: 2J23.U2-16 Projected Report Regissty ID: Based on Plans Ekotiope ID: 2,00eyWL HERS° Index Score: Annual Savings Home: 55 Your home's HERS score is a relative 18 Cortcelli St performance score.The lower the number, 2 906 Northamton, MA 01062 the more ener r effic ent the home.To Builder: learn more. risit www.liers ndex.com $'Relative to an average U.S.home John Handzel -Nu-Way Homes Inc Your Home's Estimated Energy Use: This home meets or exceeds the Use(MBtu] Annual Cost criteria of the following: Heating 26.4 $1.099 2021 !nternational Energy Conservation Code Cooling 1.7 ;29 2018 International Energy Conservation Code Hot VWater 2.0 e85 Lights/Appliances 21.8 $909 Service Charges $48 Generation (e.g.Solar) 0.0 $0 Total: 50.9 $2,171 HERS Index Home Feature Summary: Rating Completed by: P.,",.rn, Home Type: Single family detached rso Model: Jonn.'0ndzel r.u,om Energy Rater. Paul Dell3iorre Existing 140 community: Nortnam,on RESNtT ID: 8'76762 Homes lm C..nd, •oiied Floor Area: i 688 f:2 Rani-g Company: Energy Compliance Services 10 Nunr a of Bedro,n.s: 3 27 Huoson Dr.Sou:hN1ck MA 010/i Reference no Primer,Hea:nrg System: Al. Sou--e Hea•Pump L:ectric 8.5 HS-F 4.3 427 2423 MOfM 10(1 I rima Co.,iin System: Al;-Source Heat"um Ele.-tric• •4 SEEK 90 y 9 Y P Rating Provider: iu ding Erficiency Resources so Primary Water r.eating: Residential Water Heater•Electric•3 88 Energy recur PO&x:7o9 Brevard,NC 28712 70 rlor.ceTT3htness: 3 ACHS_ 800-399-9620 w^r e0 411214 Ventilation: 90 CFM 54 Watt, S0 Duct Leakage to Outside: 11 CFM @ 25Pa,0.41 /100 ft2) I '-- 1s, ao This Homo s^ r;+w... Above Grade Walls: R-23 "►.'• a r 30w Ceiling: Attic,R-60 �/� T ''""^'`� is le WmdowType: U-/alue:0.28 SHGC:0.34 �� Ue I�'Z Zero Energy o Foundation Walls: R-23 Paul DellaTorre,Certified Energy Rater u.lam Framed Floor: N/A Digitally signed:2/16/23 at 9:57 PM 01CI)PUMA e kot ro a Ekotrope RATER-Version:4.0.2.3098 p The Enerny Rating Disclosure for this home is available from the Ai proved Rating Provider ,his repo,(..ce5 not Constltl•te any warrant;or gr grantee. Energy savings ca c.i atec.without so..ifications to the eneryy model.(As M..uele.., 18 Cortcelli St Northamton MA HERS`°Index Score: Rating Date: Feb 16,2023 55 HERS Registry ID: Annual Estimates: Rating Company: .J ctn ,KWh). 14,927 1 Lnergy Compliance Services CO2 ,Tons). 96 Rating Provider. Building Efficiency Resources ApproA. 1 try,Cost: 42,171 Rating Provider Address: PO Box 1769 Brevard,NC 28712 HERS'Index Home Feature Summary: Single family detached,3 bedrooms,2 obis ft tw E, ,.a ewing.d 5 HsPF ` 1D Cooling. 4 SEER 011 ° IR ED w rentila'ion 90`FM.54 W 70 Disc!'_l O 00 11 CFM @ 25Pa(u.41/100 ft� w TMr'�O1n' move Grade Wall.:.t-23 Ceili„y:Attic.R 60 to Window:U:0.[8.SHGC:0.31 Zero E Nome G Foundation Walls:R-23 ram Ekotrope RATER-Version: I ekotrope 4.0.23098 This report does no. .on t,u:e any rerr n./or g art,tee IECC 2021 Performance Compliance Property Organization Inspection Status 18 Cortcelli St Energy Compliance Servic Results are projected Northamton. MA 01062 Paul DellaTorre Model: John Handzel Custom Commun'y: "or'ha-nton Builder John Handzel -Nu-Way 048k_John Handzel_18 Cortcelli Homes Inc St_Northampton_230216 0482_John Handzel 18 Cortcelli St_Northampton_230202 This repot is based 3n a proposed design and do-s nc,t confirm field e fc.rcP,ne. t of design e ements. Annual Energy Cos Design IECC 2021 Performance As Designed -leafing $1,260 $1,092 Cooling $95 $77 Water Heating $88 588 Mechanical Ventilation $52 $70 SubTotal - Used to determine compliance $1,495 $1,326 Lights &Appliances w/out Ventilation $872 $672 Onsite generation $0 $0 Total $2,367 $2,197 R405.3 Source Energy Exception: The proposed home uses 12.4 MBtu LESS source energy than the reference home. Requirements R405 2 Performance-based compliance passes by 11 3„,,, The proposed house meets the IECu tu21 Performance reference energy bill req_irement b, .c169 3 k 12 4 MB.u). • R405 2 Item 2 Total UA alternative compliance passes by 18 4-. The proposed home meets the UA requirement by lb 4% • R405 2 Item 2 Glazed Fenestration SHGC I® R402 4 1.2 Air Leakage Testing Air sealing is 3 00 ACH at 50 Pa and 0 21 C,FM50 ft:St.ell Area It must not emceed 5 00 ACH at 50 I-a or 0 28 CFM50 ,t'Shell Area • R403 3 1 Duct Insulation All ducts outside the thermal envelope must be insulated to at least R6 0 i® R404 1 Lighting Equipment At least 100 0%of fixtures shall be high-efficacy lamps currently 100 0%are high- efficacy ® Mandatory Checklist hMandatory code requirements that are not 2021 IECC Required Items must be checked as complete checked by Ekotrope must be met ® R403 6 2 Mechanical Ventilation Efficacy • R403 6 1 Mechanical Ventilation Energy Recovery • R402 5 Area-weighted average fenestration SHGC Area-weighted average fenestration SHGC is 0 337 The maximum allowed value is [No Limit] • R402 5 Area-weighted average fenestration U-Factor R401 2 5 Option 2 Additional energy efficiency R401 2 5 2 2-95%Threshold Met Design exceeds requirements for IECC 2021 Performance compliance by 11.3%. As a 3rd party extension of the code Jurisdiction utilizing these reports I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on riAia n Rt County If rating is rrojected I certify that the buiidin design described herein is consistent with tiie building pans specifications and other calculations sub—itted with the permit application If rating is conlrmed I certiv that the address referenced above has been inspected/tested and that the ri.andatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or vnii be verified as such by another party Name: Paul DellaTorre Signature: Paul VeflaTelle Organization: Energy Compliance Services Digitally signed: 2/16/23 at 9:57 PM Ekotrope RATER-Version 4.0.2.3098 IECC 2021 Performance compliance results calculated us,a Ehctrope RArER s e.e.g, and code ccmpl.ance alg,..t m E cot cpe RATE R 6s a..EE NET Acured.ted nEkS..a6ng lool All results are based on aata e„tered by Enotrope users Ewotrope di,claims all lia.,ilit for the imor, aton.t,o+n on t is repor IECC 2021 Building UA Compliance Property Organization Inspection Status 18 Cortcelli St Energy Compliance Servic Results are projected Northamton. MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northamton Builder John Handzel -Nu-Way 0482_John Handzel 18 Cortcelli Homes Inc St_Northampton_230216 0482_John Handzel_18 Cortcelli St_Northampton_230202 This report is based on a proposed design and does not confirm field enforcement of design elements. Building UA Elements IECC Reference As Designed Ceilings 21.6 15.5 Above-Grade Walls 112.7 130.2 Windows. Doors and Skylights 96.6 86.7 Slab Floor: 21.6 21.6 Framed Floors 0.0 0.0 Foundation malls 39.8 27.2 Rim Joists 10.0 10.5 Overall UA(Design must be equal or lower): 302.3 291.7 Requirements • R402 1 5 Total UA alternative compliance passes by 3 5% The proposed home meets the UA requirement by 3 5% ® 402 3 2 Average SHGC 0 34 Max SHGC 0 40 Average SHGC of 0 34 is greater than the maximum of 0 40 • R402 4 1 2 Air Leakage Testing Air sealing is 3 00 ACH at 50 Pa and 0 21 CFM50 ft2 Shell Area It must not exceed 5 00 ACH at 50 Pa or 0 28 CFM50.ft Shell Area • R403 3 1 Duct Insulation All ducts outside the thermal envelope must be insulated to at least R6 0 ® R404 1 Lighting Equipment At least 100 0%of fixtures shall be high-efficacy lamps currently 100 0%are high- efficacy ® Mandatory Checklist Mandatory code requirements that are not 2021 IECC Required Items must be checked as complete checked by Ekotrope must be met • R403 6 2 Mechanical Ventilation Efficacy ® R403 6 1 Mechanical Ventilation Energy Recovery ® R403 3 6 Duct Leakage Testing R403 5 2 Hot water pipe insulation Hot water pipes at least 14 in diameter must be insulated to R-3 at minimum e R402 5 Area-weighted average fenestration SHGC Area-weighted average fenestration SHGC is 0 337 The maximum allowed value is [No Limit] • R402 5 Area-weighted average fenestration U-Factor • R402 4.1 3 Prescriptive Air Leakage Air sealing is 3 00 ACH at 50 Pa It must not exceed 3 00 ACH at 50 Pa IRC M1505 4 3 Mechanical Ventilation Rate • R408 2 Additional efficiency package options I R408 2 3-Reduced energy use in service water-heating Design exceeds requirements for IECC 2021 Prescriptive compliance by 3.5%. Nance: Paul Dr.IIaTorre Signature: Pad vefla T r icy Organization: Energy Compliance Services Digitally signed: 2/16/23 at 9:57 PM Ekotrope RATER-Version 4.0.2.3098 IECC 2021 Prescriptive compliance results calculated using Ekotrope RATER's energy and code compliance al.lorithm Ekotrope RATER is a RESNET Accredited HERS Rating Tool All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report • 18 Cortcelli St Northamton, MA 01062 ,_;' Builder: John Handzel -Nu-Way Homes Inc Model: John Handzel Custom Community: Northamton This report is based on a proposed design and does not confirm field enforcement of design elements. THIS HOME IS CERTIFIED TO MEET THE 2021 INTERNATIONAL ENERGY CONSERVATION CODE Building Features Ceiling Attic, R-60 Duct Supply R-8.0, Return R-8.0 Above Grade Walls R-23 Duct Leakage to Outside 11 CFM @ 25Pa (0.41 / 100 ft2) • Fosndatiotr Walls R-23 Total Duct Leakage 100 CFM @ 25Pa (Post-Construction) }-named Floor N/A Heating Air Source Heat Pump • Electric•8.5 HSPF Slab R-0.0 Perimeter, R-0.0 Under Cooling Air Source Heat Pump• Electric• 14 SEER Infiltration 3 ACH50 Water Heating Residential Water Heater• Electric• 3.88 Energy Factor Window U-Value: 0.28, SHGC: 0.34 As a 3rd party extension of the code jurisdiction utilizing these reports I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on HAMPSHIRE County If rating is Projected,I certify that the building design described herein is consistent with the building plans.specifications,and other calculations submitted with the permit application If rating is Confirmed.I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Paul DellaTorre Signature: Pad Odra Tale Organization: Energy Compliance Services Digitally signed: 2/16/23 at 9:57 PM Ekotrope RATER-Version 4.0.2.3098 2021 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm Er.otrope RATER is a RESNET Accredited HER•Rating Tool AN results are based on data entered by Ekotrope users • Ekotrope disclaims all Ha Aility for the information shown on this report I • IECC 2021 Label 18 Cortcelli St Model: John Handzel Custom Ekotrope RATER -Version: 4.0.2.3098 Building Envelope Specs Ceiling: R-60 Above Grade Walls: R-23 Foundation Walls: R-?3 Exposed Floor: N/A Slab: R-0 Infiltration: 3 ACH50 Duct Insulation: Supply: R8, Return: R8 Duct Lkg to Outdoors: 11 CFM @ 25Pa (0.41 / 100 ft2) Window & Door Specs U-Value: 0.28, SHGC: 0.34 Door: R-6 Heating:Air Source Heat Pump• Electric•8.5 HSPF Cooling:Air Source Heat Pump - Electric• 14 SEER Hot Water: Residential Water Heater - Electric• 3.88 Energy Factor Average Mechanical Ventilation: 90 CFM Builder or Design Professional Signature: Air Leakage Report Property Organization Inspection Status 18 Corticelli St Energy Compliance 3e►vic Results are projected Northamton, MA u1062 Paul Dell.Torre Model: John Handzel Custom Community: Northamtol i Builder John Handzel -Nu-Way 04d2 John Handzel 1 t' Corticel.i Homes Inc St Northampton 230216 0432 John Handzel 18 Cortcerli St_Northampton_230202 General Information Conditioned Floor Area [ft2] 2,688 Infiltration Volume[ft3] 22,500 Number of Bedrooms 3 Air Leakage Measured Infiltration 3 ACH50 ACH50 (Calculated) 3.00 ELA[sq. in.] (Calculated) 61.72 ELA per 100 s.f. Shell Area (Calculated) 1.128 CFM50(Calculated) 1,125 CFM50/s.f. Shell Area (Calculated) 0.206 Duct Leakage System 1 Leakage to Outdoors 11 CFM @ 25Pa (0.41 / 100 ft2) Total Leakage Test Type Post-Construction Total Leakage[CFM @ 25 Pa] 100.0 Total Leakage [CFM25/ 100 s.f.] 3.7 Total Leakage[CFM25/CFA] 0.037 Mechanical Ventilation Rate [CFM] 90 CFM Hours per day 24.0 Fan Power 54 Watts Recovery Efficiency% 65.0 Runs at least once every 3 hrs? true Average Rate [CFM] 90.0 CFM 2010 ASHRAE 62.2 Req. Cont. Ventilation 56.9 2013 ASHRAE 62.2 Req. Cont. Ventilation 72.4 Ekotrope RATER-Version 4.0.2.3098 All le uns are b sed on data en e•ed by Lkob DE user t_kot.ix disci Os all liability ur: ..nform,tio, shown oh.this report Emissions Summary Property Organization Inspection Status 18 Corticelli St Energy Compliance Servic Results are projected Northamton, MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northamton Builder John Handzel -Nu-Way 0482_John Handzel 18 Corticelli Homes Inc St_Northampton_230216 0482_John Handzel 18 Cortcelli St_Northampton_230202 Emissions by End-Use Carbon Dioxide (CO2) [tons/yr] Heating 4.9 Cooling 0.1 Water Heating 0.4 Lights &Appliances 4.1 Photovoltaics -0.0 TOTAL 9.6 Sulfur Dioxide (SO2) [Ibs/yr] Heating 12.4 Cooling 0.3 Water Heating 1.0 Lights &Appliances 10.2 Photovoltaics -0.0 TOTAL 23.9 Nitrogen Oxide (NO.) [Ibs/yr] Heating 7.0 Cooling 0.2 Water Heating 0.5 Lights&Appliances 5.8 Photovoltaics -0.0 TOTAL 13.4 Energy Use Intensity (EUI) [kBtu/ft2] Site EUI 19.0 Ekotrope RATER-Version 4.0.2.3098 All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report Fuel Summary Property Organization Inspection Status 18 Corticelli St Energy Compliance Services Results are projected Northamton, MA 01062 Pau; DelaTorre Model:John,land.el Custom Community: Northamton Builder John Handzel-Nu-Way 0482_John nan&el 18 Corticelli Homes Inc St_Northampton 2's0216 0482 John.iand.el 18 Cortcelli St_Northampton_230202 Annual Energy Cost Electric $2.171 Annual End-Use Cost Heating $1,099 Cooling .029 Water Heating $85 Lights &Appliances $909 Onsite Generation -$0 Service Charges $48 Total $2,171 Annual End-Use Consumption Heating [Electric kWh] 7,729.8 Cooling [Electric kWh] 207.0 Hot Water[Electric kWh] 599.5 Lights&Appliances[Electric kWh] 6,390.8 Total [Electric kWh] 14,927.1 Total Onsite Generation [Electric kWh] 0.0 Peak Electric Consumption Peak Winter kW 3.80 Peak Summer kW 1.45 Utility Rates Electricity National Grid Ekotrope RATER-Version 4.0.2.3098 All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report Building Specification Summary Property Organization Inspection Status 18 Corticelli St Energy Compliance Servic Results are projected Northamton, MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northamton Builder John Handzel -Nu-Way 0482_John Handzel 18 Corticelli Homes Inc St_Northampton_230216 0482 John Handzel 18 Cortcelli St_Northampton_230202 Building Information Rati:rg Conditioned Area [ftz] 2.688.00 HERS Index 55 Conditioned Volume [ft'] 22.500.00 HERS Index w!o PV 55 Thermal Boundary Area [ft2] 5.472.00 Number Of Bedrooms 3 Housing Type Single family uetar.hed Building Shell Ceiling w'Attic R-60 Blown.Attic 2x8; U-0.017 Windows (largest) U-Value: 0.28. SHGC: 0.34 Vaulted Ceiling I None Window/Wall Ratio 10.11 Above Grade Walls(R-23 rock wool: U-0.056 Infiltration 3 ACH50 Found. Walls I R-13 in + R-10 GL to bottom: R-23 Duct Lkg to Outside 111 CFM @ 25Pa (0.41 / 100 ft2) Framed Floors None Total Duct Leakage 1100 CFM @ 25Pa (Post-Construction) Slabs(Uninsulated 1: R-0 Mechanical Systems Heating Air Source Heat Pump• Electric•8.5 HSPF Cooling Air Source Heat Pump• Electric• 14 SEER Water Heating Residential Water Heater• Electric• 3.88 Energy Factor Programmable Thermostat Yes Ventilation System 90 CFM • 54 Watts Whole House Fan N/A • Lights and Appliances Percent Interior LED 100% Clothes Dryer Fuel Electric Percent Exterior LED 100% Clothes Dryer CEF 3.0 Refrigerator(kWhiyr) 596.0 Clothes Washer LER(kWh/yr) 400.0 Dishwasher Efficiency 270 kWh Clothes Washer Capacity 3.0 Ceiling Fan (CFM/Watt) 79.0 Range/Oven Fuel Electric Ekotrope RATER-Version 4.0.2.3098 All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report Building Summary Property Orio-i...;.or Inspection Status 18 Corticem St E..eryy Comi Hance Services Results are projected Northamton,MA 0106z Paul DellaTorre Mc.el Joho riandcel Custom Community-Nolhamton Builder Jo:,n Handsel Nu Way Home;Inc 0482 John Handzel 18 Corticelli St Northamrton_230_10 0482_John Handzel 18 Cortcelli St_Northampton_2:&3z General Building Information Number Of Bedrooms 3 Number Of Floors 2 Conditioned Floor Area[sq.ft] 2,688 Has Electric Vehicle Ready Space No Unconditioned.attached garage? No Conditioned Volume[cu ft] 22,500 Total Units in Building 1 Residence Type Single family detached Number of Floors in Building - Floor Number - Model John Handzel Custom Community Northamton RESNET/IECC 2006-2018 Climate Zone 5A IECC 2021 Climate Zone 5A Foundation Wall ti;rne. Library Type Height Above Grade Dept uelowGra<it Perimeter Locatio losing 0 below grade R-13 in+R-10 GL to 0.5 5.5 136 Exposed Exterior Conditioned Space bottom Foundation Wall Library List - ill Name Feet From Wall Top Tc 'eet From Wail Top To Is Fully Insulated Continuous R-value Cavity R-value Et e_Uve Insulation R- Continuous Insulation Continuous Insulation value Top Botto n R-13 n+R-10 GLto N/A N/A Yes 23 00 N/A N/A botto l Name Library type Perimeter Floor Grade Carpet R Exposed 3urtaoe Area L• '•n Enclosing Masonry Area below grade slab Uninsulated'•'_` Below Grade 0 0 -._- .------900.0 ft' Exposed Exk- ndition,- : Space Slab Library List Name Wall Construction Slab Completely Understate Perimeter Perimeter Thermal Break Effective R-value Type Insulated? Insulation Width(ft] Insulation Depth[ft] Insulation R Value Unmsulaled"' 1 Wood Frame/Other 1 Energy Code Inspection Checklist Property Organization Inspection Status 18 Corticelli St Energy Compliance Servic Results are projected Northamton, MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northamton Builder John Handzel -Nu-Way 0482_John Handzel_18 Corticelli Homes Inc St_Northa m pton_230216 0482_John Handzel_18 Cortcelli St_Northampton_230202 General Building Information Conditioned Area (sq ft) 2,688 Conditioned Volume(cubic ft) 22,500 Insulated Shell Area (sq ft) 5,472 The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab • Name: below grade slab(900 s.f., 120 ft. exterior perimeter) ' _.1 R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall Name: 0 below grade (E)-terior Perimeter[ft]: 136, Height Above Grade[ft]: 0.5, Depth Below Grade [ft]: 5.5) R-23 continuous insulation, R-0 cavity insulation Insulation Grade: I Fully insulated (top to bottom) Above Grade Wall rl Name: 1 to ambient (1,224 s.f.) R-0 continuous insulation, R-23 cavity insulation Insulation Grade: I 1 Name: 2 to ambient(1,050 s.f.) R-0 continuous insulation, R-23 cavity insulation Insulation Grade: I ' ' Name: 2 to attic(38 s.f.) 1 R-0 continuous insulation, R-23 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization Inspection Status 18 Corticelli St Energy Compliance Servic Results are projected Northamton, MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northamton Builder John Handzel -Nu-Way 0482_John Handzel_18 Corticelli Homes Inc St_Northampton_230216 0482_John Handzel_18 Cortcelli St_N ortha m pton_230202 - Name: above grade foundation (272 s.f.) - R-13 continuous insulation, R-0 cavity insulation Insulation Grade: I Rim Joist i- Name: 0 to ambient(136 s.f.) '—' R: 21.00 Name: 1st to ambient (136 s.f.) R: 21.00 Ceiling / Roof Name: flat with attic (900 s.f.) R-34 continuous insulation, R-26 cavity insulation Insulation Grade: I Opaque Door El Name: 0 to ambient(20 s.f.) R: 5.50 El Name: front 1/2 (10 s.f.) R: 5.50 El Name: side 1/2 (10 s.f.) R: 5.50 Glazing El Name: 0 LW(8 s.f.), U: 0.300, SHGC: 0.3, Orientation: SOUTH_EAST Name: 0 BW(4 s.f.), U: 0.300, SHGC: 0.3, Orientation: SOUTH_WEST 2 Name: 0 RW(8 s.f.), U: 0.300, SHGC: 0.3, Orientation: NORTH_WEST Energy Code Inspection Checklist Property Organization Inspection Status 18 Corticelli St Energy Compliance Servic Results are projected Northamton, MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northamton Builder John Handzel -Nu-Way 0482_John Handzel 18 Corticelli Homes Inc St_Northampton_230216 0482_John Handzel 18 Cortcelli St_Northampton_230202 Ei Name: 1 FWd (10 s.f.), U: 0.280, SHGC: 0.34, Orientation: N >RTH_EAST fl Name: 1 FW(30 s.f.), U: 0.280, SHGC: 0.34, Orientation: NORTH_EAST Name: 1 LW(27.5 s.f.), U: 0.280, SHGC: 0.34, Orientation: SOUTH_EAST 111 Name: 1 LWd (10 s.f.), U: 0.280, SHGC: 0.34, Orientation: SOUTH_EAST • Name: 1 BW(30 s.f.), U: 0.280, SHGC: 0.34, Orientation: NORTH_WEST U Name: 1 RW(25 s.f.), U: 0.280, SHGC: 0.34, Orientation: NORTH_WEST • Name: 2 FW(28.3 s.f.), U: 0.280, SHGC: 0.34, Orientation: NORTH_EAST 0 Name: 2 FW(10 s.f.), U: 0.280, SHGC: 0.34, Orientation: NORTH_EAST ri Name: 2 LW(30 s.f.), U: 0.280, SHGC: 0.3-r, Orientation: SOUTH_EAST • Name: 2 LW(12 s.f.), U: 0.280, SHGC: 0.34, Orientation: SOUTH_EAST Name: 2 LW(8 s.f.), U: 0.280, SHGC: 0.34, Orientation: SOUTH_EAST 0 Name: 2 BW(28.3 s.f.), U: 0.280, SHGC: 0.34, Orientation: SOUTH_WEST Name: 2 RW(13 s.f.), U: 0.280. SHGC: 0.34, Orientation: NORTH_WEST Skylight None Present Mechanical Ventilation Mechanical ventilation system rated for, and capable of, providing continuous ventilation. 3 4-4 System shall include automatic timing controls. System type: ERV, 24 hrs/day, 54 Watts Energy Code Inspection Checklist Property Organization Inspection Status 18 Corticelli St Energy Compliance Servic Results are projected Northamton, MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northamton Builder John Handzel -Nu-Way 0482_John Handzel_18 Corticelli Homes Inc St_Northampton_230216 0482_John Handzel_18 Cortcelli St_Northampton_230202 Mechanical Equipment Air-source heat pump (1)• Electric• 100% Heating Load @ 8.5 HSPF, 100% Cooling Load @ 14 SEER El Water Heating (2)• Electric• 100% Hot Water Load @ 3.88 Energy Factor Air Leakage Control El Test Status: Blower-door tested House is air-sealed as to achieve 1,125 CFM50 (3.00 ACH50)or less at final blower-door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 2018 IECC Infiltration limit for the design home is 3 ACH50. 2021 IECC Infiltration limit for the design home is 5 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 11 CFM @ 25Pa (0.41 / 100 ft') Total Leakage specified as: 100 CFM @ 25Pa (Post-Construction) 4 Energy Code Inspection Checklist Property Organization Inspection Status 18 Corticelli St Energy Compliance Servic Results are projected Northamton, MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northamton Builder John Handzel -Nu-Way 0482_John Handzel_18 Corticelli Homes Inc St_Northampton_230216 0482_John Handzel_18 Cortcelli St_Northa m pton_230202 Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25/ 100 sq ft CFA. Rough in Test with AHU:Total Duct Leakage <= 6 CFM25/ 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <=4 CFM25/ 100 sy ft CFA. 2012 IECC Mandatory, 2015, 2018, & 2021 IECC Prescriptive Paths: Postconstruction Leakage Test:Total Duct Leakage<=4 CFM25/ 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <=4 CFM25/ 100 sq ft CFA. Rough in Test without AHU:Total Duct Leakage <= 3 CFM25/ 100 sq ft CFA. ' Note: IECC 2021 requires Total Duct Leakage<= 8 CFM25/ 100 sq ft CFA when all ducts and air handlers are within the ouilding thermal envelope. 2015 and 2018 IECC Performance Paths (Cost Compliance): Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 5 Building Summary Property Organization Inspection Status 18 Corticelli St Energy Compliance Services Results are projected Northamton MA 01062 Paul DellaTorre Model John Handzel Custom Community Northamton Builder John Handzel-Nu-Way Homes Inc 0482 John Handzel 18 Corticelli St Northampton230216 0482 John Handzel 18 Cortcelli St_Northam pton_230202 Framed Floor Framed Floor Library List Rim Joist .11111111111 Name Library type Surface Area Location 0 to ambient R 21.0 136 0 11' Exposed Exterior 1st to ambient R 21.0 136 0 tt' Exposed Exterior Rim Joist Library List Name Effective Insulation R-value R 21 0 21 0C Wall ti E Ubrary Surface Color Surface Area Location 1 to ambient R-23 rods wool Medium 224.0 ff' Exposed Extenor 2 to ambient R-23 rock wool tAedlum 1,050.0 R' Exposed Exterior 2 to attic R-23 rock wool tedium 38.0 rt' Exposed Exterior above grade foundation toundabon AG R-13 Medium 272 0 tt' Exposed Extenor 2 Building Summary Property Organization Inspection Status 18 Corticelli St Energy Compliance Services Results are protected Northamton,MA 01062 Paul DeltaTorre Model John Handzel Custom Community Northamton Builder John Handzel-Nu-Way Homes Inc 0482_John Handzel 18 Corticelli St Northampton_230216 0482 John Handzel 18 Cortcelli St_Northampton_230202 f Wall Library List Name Effective R-value 1 R-23 rock wool 17.94 foundation AG R-13 14.96 po lazing u Name Library type Wall Foundation Is Operable Overhang Overhang Ft To Overhang Ft To O entation Surface Area Assignment Wall Depth Top Bottom Assignment 0 BW .30.30 1 to ambient e.. _ 0 0 Southwest 4.082 0 LW .30.30 1 to ambient Yes 0 0 C Southeast 8.0 t' 0 RW .30 30 1 to ambient Yes 0 0 0 Northwest 8 0 t' 1 BW .28.34 1 to ambient Yes 0 0 0 Northwest 30.0 t' 1 FW 28 34 1 to ambient Yes 8 2 6 Northeast 30.0 t' 1 FWd .28.34 1 to ambient • Yes 7 2 6 Northeast 10 0 t' 1 LW .28 34 1 to ambient Yes 0 0 0 Southeast 27-5 1' 1 LWd .28.34 1 to ambient Yes 0 0 0 Southeast 10.0 t' 1 RW 28 34 1 to ambient Yes 0 0 0 Northwest 25.0 t' 2 BW .28.34 2 to ambient Yes 1 1 5.8 Southwest 28 3 t' 2 FW 28.34 2 to ambient Yes 0 0 0 Northeast 28.3 t' 2 RN 28 34 2 to ambient Yes 1 1 6 Northeast 10.0 t' 2 LW .28_34 2 to ambient Yes 0 0 0 Southeast 30.0 t' 2 LW .28.34 2 to ambient Yes 0 0 0 Southeast 12.0 t' 2 LW .28 34 2 to ambient Yes 0 0 0 Southeast 8 0 t' 2 RW 28 34 2 to ambient Yes 0 0 0 Northwest 13.0 t' 3 Building Summary Property Organization Inspection Status 18 Corticelli St Energy Compliance Services Results are projected Northamton.MA 01062 Paul Della Torre Model John Handzel Custom Community'Northamton Builder John Handzel-Nu-Way Homes Inc 0482 John Handzel 18 Corticelli St Northampton_230216 0482 John Handzel 18 Cortcelli St_Northampton_230202 Glazing Library List '` Name Shgc U4actor .28 34 0.34 0.280 i30.30 0.3 0.300 kylight None Present Oh.Skylight Library List' - - _ Name _fbrary Type Wall Assignment Foundation Wall Emittance Solar Surface Color S .-., Area Location Assignment Absorptance 0 to ambient insulated door 0 below grade 0.9 0.75 Medium 0.0112 Exposed Exterior front 1.i 1 to ambient 0.9 075 Medium 0.0 R' Exposed Exterior side 1/2 Insulated door 1 to ambient 0.9 0.75 Medium {0-0 it' Exposed Exterior r Opaque Door Library List ry a^,e Effective R-value I 4 Building Summary Property Organization Inspection Status 18 Corticelli St Energy Compliance Services Results are projected Northamton.MA 01062 Paul DenaTorre Model John Handzel Custom Community Northamton Builder John Handzel-Nu-Way Homes Inc 0482 John Handzel 18 Corticelh St Northampton230216 0482 John Handzel 18 Cortcelli St_Northampton_230202 Roof Insulation I r,,ame Library type Attic EzbriorAnsa(ft, Clay or Concrete Roof Tiles Surface Color Surface A Location Rat with attic R-60 Blown,Attic 2x8 1.125 No Medium 900.0 Tr Attic I Roof Insulation Library List , !game -a Racia-•Ear-.e- " eR-value R-60 Blown Attic 2x8 No 58.088 Whole House Infiltration Intiltraticr Me3su-emert T e S"e te- :ac. 3ACHat50Pa Mechanical Ventilation r .erti 3t1ar 'Pr Pe ve ,ilat_, Rae s. j4:eratC .—tt: R,. e e.e-. cr--t Fecc Yr, M:c rrt , e N... •ce• a^..•.�,.,.-e r.l ta" cc' _ . c r r _ ::e^ I Lighting %Interior Fluorescent Interior LED Lighting Exterior Fluorescent Exterior LED Lighting Garage Fluorescent Garage LED ughunc: Lighting Lighting Lighting Onsite Generation a Building Summary Property Organization Inspection Status 18 Corticelli St Energy Compliance Services Results are protected Northamton MA 01062 Paul DellaTorre Model John Handzel Custom Community Northamton Builder John Handzel-Nu-Way Homes Inc 0482 John Handzel 18 Corticelli St_N o rt h a m pt o n_2 30216 0482_John Handzel 18 Cortcelli St_No rt ha m pto n_230202 Onsite Generation Library List F'-_- ent Solar Generation Dehumidifier INone Present Dehumidifier Library List iMc'€- e: ' Whole House Fan None Present Whole House Fan Library List I ' :re P.E:e.. Conditioning Equipment Name "ibrary Type Senal Number Heating Percent Load Cooling Percent Load Hot Water Percent Location Load Au-source heat pump Amer-Stan- 100% 100% 0% Conditioned Space (11 4A6H4030G1- TFIeennw Water Heating(21 Elctnc Heat pump 50 0% 0% 100% Conditioned Space 3 88 6 Building Summary Property Organization Inspection Status 18 Corticelli St Energy Compliance Services Results are projected Northamton MA 01062 Paul DellaTorre Model John Handzel Custom Community Northamton Builder John Handzel-Nu-Way Homes Inc 0482 John Handzel 18 Corticelli St_No rth ampto n_230216 0482 John Handzel 18 Cortcelli St_No rt h am pion_230202 Equipment Type: Amer-Stan-4A6H4030G1 - TEM4A0B EquipmentTypc Air So. Fuel Type Electric Distribution Type Forced Air Motor Type ECM(Variable Speed Heating Efficiency 8 5 HSPF Heating Capacity[kBtu'h] 27 8 Backup Fuel Type Electric Switchover Temperature 1°F] 0 Backup Heating Efficiency 1 Adjusted Efficiency Use default Supplemental Heat No Supplemental Heat[kW] 10 Cooling Efficiency 14 SEER Cooling Capacity[kBtu.'h] 28 Equipment Type: Elctric Heat pump 50 3.88 111111.111 Equipment Type Residential Water Heater Fuel Type --------- -------- -- - Electric Distribution Type Hydronic Delivery(Radiant) Hot Water Efficiency 3 88 Energy Factor Tank Capacity(gal) 50 7 Building Summary Property Organization Inspection Status 16 Corticelli St Energy Compliance Services Results are protected Northamton MA 01062 Paul DellaTorre Model John Handzel Custom Communih Northamton Builder John Handzel-Nu-Way Homes Inc 0482 John Handzel 18 Corticelli St Northampton 230216 0482 John Handzel 18 Cortcelli St_No rt h am pton_230202 Distribution System Distribution Type Forced Air Heating Equipment Air-source heat pump(1) Cooling Equipment Air-source heat pump(1) Sq Feet Served 2 688 #Return Grilles 7 Supply Duct R Value 8 Return Duct R Value 8 Supply Duct Area(ft2] 725 8 Return Duct Area Iftz] 672 Leakage to Outdoors 11 CFM @ 25Pa(0 41 100 ft'i Total Leakage 100 CFM25 Total Leakage Duct Test Conditions Post-Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 80 Percent Return Area 90 Duct 2 Duct Location Attic(well vented) Percent Supply Area 20 Percent Return Area 10 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 HVAC Grading HVAC Grading Not Conducted Ceiling Fan _ r.___ .,...::: Has Ceiling FanI Yes Cfm Per Watt 79 8 Building Summary Property Organization Inspoctton Status 18 Corticelli St Energy Compliance Services Results are projected Northamton MA 01062 Paul DellaTorre Model John Handzel Custom Community Northamton Builder John Handzel-Nu-Way Homes Inc 0482 John Handzel 18 Corticelli St Northampton230216 0482 John Handzel 18 Conce@ St_No rth a m pto n_230202 Water Distribution Water Fixture Type Low-flow Use Default Hot Water Pipe Length No Hot Water Pipe Length[ft] 50 At Least R3 Pipe Insulation'? Yes Hot Water Recirculation System? No Recirculation System Pipe Loop Length[ft] 30 Drain Water Heat Recovery'? No Clothes Dryer Cef 3 01 Fuel Type Electric Field Utilization Timer Controls Is Outside Conditioned Space No Clothes Dryer Available Yes Defaults Type HERS Reference Clothes Washer Label Energy Rating 400 kWh/Year Annual Gas Cost $27 00 Electric Rate $0 12/kWh Gas Rate $1 09 Therm Capacity 3 !met 1 Defaults Type HERS Reference Load Type Front-load Loads Per Week 6 Is Outside Conditioned Space No Clothes Washer Available Yes s w Dishwasher Efficiency 270 kWh Dishwasher Size Standard Annual Gas Cost $23 00 Electric Rate $0 12/kWh Gas Rate $1 09/Therm Is Outside Conditioned Space No 9 Building Summary Property Organization Inspection Status 18 Corticelli St Energy Compliance Services Results are projected Northamton MA 01062 Paul DellaTorre Model John Handzel Custom Community Northamton Builder John Handzel-Nu-Way Homes Inc 0482 John Handzel 18 Corticelh St_Northampton 230216 0482 John Handzel 18 Cortcelli St_No rt ha m pton_230202 Appliances and Controls Programmable thermostat') Yes Range/Oven Fuel Electric Convection Oven') Yes Induction Range'? No Range/Oven Outside Conditioned Space? No Refrigerator Consumption 596 kWh'Year Refrigerator Outside Conditioned Space? No q. 10 Builder Affidavit Property Organization Inspection Status 18 Corticelli St Energy Compliance Servic Results are projected Northamton, MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northamton Builder John Handzel -Nu-Way 0482_John Handzel_18 Corticelli Homes Inc St_N ortham pton_230216 0482_John Handzel_18 Cortcelli St_Northa m pton_230202 Important Notice to Builder Builder affirms in this affidavit that all building characteristics described in the Building Summary Report accurately reflect this New Home. Builder agrees to allow the Home Energy Rating System (HERS) Provider and/or Rater to verify building characteristics of this New Home fully at the HERS Rater/Provider's discretion. The HERS Provider and Rater do not create or imply any duty or obligations to Builder or any subsequent owner. Builder is responsible for taking any actions necessary to protect Builder's interest. There is no guarantee or warranty whatsoever expressed or implied from the HERS Provider or Rater. HERS® Index Score:55 Builder Name: John Handzel -Nu-Way Homes Inc Builder Signature: Name: Paul DellaTorre Signature: Organization: Energy Compliance Services Date: 2/16/23 at 10:25 PM Ekotrope RATER-Version 4.0.2.3098 All results are based on data entered by Ekotrope users Ekotrope disclaims al liability for the information shown on this report End Use Energy Costs Property Organization Inspection Status 18 Corticelli St Energy Compliance Servic Results are projected Northamton, MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northamton Builder John Handzel -Nu-Way 0482_John Handzel 18 Corticelli Homes Inc St_Northampton 230216 0482_John Handzel_18 Cortcelli St_Northampton_230202 Annual Energy Cost $1,000 $800 $600 chi to $400 $200 $0 Heating Cooling Water Heater Lights &Appliances Service Charges Ekotrope RATER-Version 4.0.2.3098 All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report Component Loads Property Organization Inspection Status 18 Corticelli St Energy Compliance Servic Results are projected Northamton, MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northamton Builder John Handzel -Nu-Way 0482_John Handzel_18 Corticelli Homes Inc St_Northampton_230216 0482_John Handzel_18 Cortcelli St_Northampton_230202 Heating & Cooling Loads 20 18 16 14 12 10 co to >' 8 i6 I IA_ ir_ -2 -4III -6 Above-Grade Infiltration & Slabs & Roofs Ducts Windows & Foundation Internal Walls Ventilation Floors Doors Walls Gains Heating ■ Cooling • Ekotrope RATER-Version 4.0.2.3098 All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report Component Costs Property Organization Inspection Status 18 Corticelli St Energy Compliance Servic Results are projected Northamton, MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northamton Builder John Handzel -Nu-Way 0482_John Handzel_18 Corticelli Homes Inc St_Northampton_230216 0482 John Handzel_18 Cortcelli St_Northampton_230202 Heating & Cooling Costs 450 400 350 300 250 200 4-37, 150 100 50 „_ -50 -100 -150 Above-Grade Infiltration & Slabs & Roofs Ducts Windows & Foundation Internal Walls Ventilation Floors Doors Walls Gains Heating ■ Cooling • Ekotrope RATER-Version 4.0.2.3098 All results are based on data entered by Ekotrope users Ekotrope disclaims al liability for the information shown on this report Energy Appraisal Addendum Property Organization Inspection Status 18 Corticelli St Energy Compliance Servic Results are projected Northamton, MA 01062 Paul DellaTorre Model: John Handzel Custom Community: Northamton Builder John Handzel -Nu-Way 0482_John Handzel_18 Corticelli Homes Inc St Northampton_230216 0482_John Handzel 18 Cortcelli St_N orth a m pton_230202 This form may be attached to the Uniform Residential Appraisal Report(FHLMC Form 70; FNMA Form 1004)and submitted along with the Home Energy Rating Certificate. In order to estimate the value of the energy efficiency of the dwelling, and in the absence of comparable sales or other traditional methods of valuation, the appraiser has reviewed the estimate of added cost due to energy efficiency and calculated the net present worth (NPW)of the improved energy efficiency based on documentation provided by the Certified Home Energy Rating System (HERS)Energy Rater. The incremental value due to energy efficiency, based on the lesser of the improvement cost or NPW estimate, is determined to be$ ,which represents an addition to the market value concluded in the Appraisal Report. ADJUSTED VALUE MARKET VALUE $ CONCLUSION ENERGY-EFFICIENCY INCREMENT $ TOTAL ESTIMATED VALUE $ Appraiser Signature Date Special Limiting condition for use with EEM/EIM Pilot Program In the final estimate of total value, the appraiser has included added value based on the lower of the additional cost due to energy efficiency or the NPW calculation of the projected energy savings provided by the Certified HERS Energy Rater. The appraiser takes no responsibility for the accuracy of the calculation provided by the Rater. The valuation methodology used by the appraiser of including the cost or NPW calculation represents a valid approach as stipulated in the Fannie Mae EEM/EIM Pilot Program.The projected energy savings used to determine NPW are not guaranteed and are subject to variance based on occupant behavior, after-sale home modifications, and degradation over time. Energy Appraisal Addendum (Fannie Mae EEfcm(,FeIMpPeil�gjeln)Version 4.0.2.3098 All results are based on data entered by Ekotrope users Ekotrope disclaims at liability for the information shown on this report New Home Energy Efficient Mortgage Report Borrower Name: Property Address: 18 Corticelli St, Northamton. MA 01062 Monthly Savings $145 The Monthly Savings is the average estimated monthly energy savings of the rated home compared to the RESNET®Home Energy Rating System(HERS®) reference home Energy Savings Value $33,371 The Energy Savings Value is the Net Present Value of the estimated annual energy savings of the rated home compared to the HERS re rence home calculated over a lifetime of 30 years Mortgage Period: 30 years Mortgage Rate: 4_09 % Down Payment: 10 RESNET standards dictate that Mortgage Period.Rate and Down Payment must be shown in this report_ These values do not impact the Monthly Savings or Energy Savings Value shown above. Nam: ► •• D: - & ► Organization: • ere, Co • an•!-rvi•- at 10:25 PM RESULTS PROJECTED Ekotrope RATER-Version 4.0.2.3098 AN results are based on data entered by Ekotrope users Ekotrope disclaims al liability for the information shown on this report •